Read X-RAY.pdf text version

KD7405CWT/KD7405DWT/KD7405DWH

The new high-sensitivity sensor and new algorithm detect minute metal contaminants as small as 0.2 mm dia. See page 17 for safer operation.

X-ray Inspection System KD74-h series

Belt width

dia. Leg spacing Leg spacing

Line heights

to

dia. Roller

Pass height

Contaminant Inspection System

25 18

Dust and waterproof Package check Relative mass measurement (Option) protection class

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection 10 Classifications confirmation (Option) (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7405CWT KD7405DWT KD7405DWH

KD7405DWH

Detection area

Effective detection width

Units: mm

Specifications

Model Detection sensitivity X-ray output Safety Display Operation method Product size Note 3 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 4 Maximum product weight

Note 5 Note 1

KD7405CWT Fe sphere and SUS sphere 0.2 mm dia.

KD7405DWT

Note 2

, SUS wire 0.2 mm dia. x 2 mm long

Power requirements Mass Environmental conditions Note 8 Protection class Exterior

Note 6, Note 7

Tube voltage 25 to 60 kV, Tube current Tube voltage 25 to 80 kV, Tube current 0.3 to 10.0 mA, Output 7.5 to 350 W 0.3 to 7.0 mA, Output 7.5 to 300 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 240 mm, Maximum height: 120 mm (Detection area is shown above.) 270 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 10 to 60 m/min, Maximum 5 O 10 to 90 m/min, Maximum 2 O 5 to 40 m/min, Maximum 10 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 230 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

KD7405DWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : Reference value using Anritsu test piece. Note 3 : The entrance and exit may require covers depending on the length of a product. Note 4 : Variable depending on Product No. Note 5 : Sum total of product weight on the conveyor. Note 6 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 7 : Installing the air-conditioner option changes the displayed power consumption. Note 8 : The air-conditioner option may be required depending on the operating environment.

KD7416DWH

See page 17 for safer operation.

X-ray Inspection System KD74-h series

Contaminant Inspection System Anritsu's unique new algorithm for the new x-ray generator achieves high-sensitivity detection of low-contrast contaminants, such as bone and plastics.

Dust and waterproof Package check Relative mass measurement protection class (Option)

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation (Option)

16 Classifications (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7416DWH

KD7416DWH

Detection area

Line heights

Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight Note 4 Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7416DWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 80 kV, Tube current 0.3 to 10.0 mA, Output 7.5 to 350 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 390 mm, Maximum height: 150 mm (Detection area is shown above.) 420 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 60 m/min, Maximum 5 O 5 to 40 m/min, Maximum 10 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 280 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

19

KD7417DWH

See page 17 for safer operation.

X-ray Inspection System KD74-h series

The new x-ray generator supports high-quality x-ray images. Even the wide type can detect low-contrast contaminants with high sensitivity.

Line heights

Contaminant Inspection System

25 20

Dust and waterproof Package check Relative mass measurement protection class (Option)

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation (Option)

16 Classifications (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7417DWH

KD7417DWH

Detection area

335 Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight Note 4 Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7417DWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 80 kV, Tube current 0.3 to 10.0 mA, Output 7.5 to 350 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 390 mm, Maximum height: 220 mm (Detection area is shown above.) 420 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 40 m/min, Maximum 10 O 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 280 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

KD7405AWH/KD7405ADWH/KD7405BWH/KD7405BDWH

A stainless steel wire of 0.2 mm dia. and 2 mm long can be detected. High-sensitivity detection of individually packaged products is also supported. See page 17 for safer operation.

X-ray Inspection System

Contaminant Inspection System

Dust and waterproof Package check Relative mass measurement (Option) protection class

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

10 Classifications Rejection (Option) confirmation (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7405AWH KD7405BWH KD7405ADWH KD7405BDWH

270

KD7405AWH

465

Detection area

730 160 120 240

Belt width

W 500

120 Pass height

265

33.5 dia. Roller

700 to 800 Line heights 1360 to 1460

(8

0)

Effective detection width 240

Model W KD7405AWH 800 KD7405BWH KD7405ADWH 1000 KD7405BDWH

(640)

450 Leg spacing

60 dia.

(240)

196 605 Leg spacing

Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight

Note 4

Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7405AWH KD7405ADWH KD7405BWH KD7405BDWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 60 kV, Tube current 0.3 to 7.0 mA, Tube voltage 25 to 80 kV, Tube current 0.3 to 7.0 mA, Output 7.5 to 210 W Output 7.5 to 210 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 240 mm, Maximum height: 120 mm (Detection area is shown above.) 270 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 60 m/min, Maximum 5 O 5 to 90 m/min, Maximum 2 O 5 to 40 m/min, Maximum 10 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 210 O 215 O 220 O 225 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

21

KD7416AWH/KD7416ADWH/KD7416BWH/KD7416BDWH

Contaminants in large and wide products can be detected with high sensitivity. Contaminants in bulk products can also be detected. See page 17 for safer operation.

X-ray Inspection System

540

Belt width

420

880

340

390

W 500 150 Pass height

33.5 dia. Roller

700 to 800 Line heights 1530 to 1630

(80

)

Effective detection width 390

Model KD7416AWH KD7416BWH KD7416ADWH KD7416BDWH

W 800 1000

450 Leg spacing

60 dia.

(650)

(280)

271 755 Leg spacing

150

Contaminant Inspection System

25 22

Dust and waterproof Package check Relative mass measurement protection class (Option)

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation (Option)

16 Classifications (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7416AWH KD7416BWH KD7416ADWH KD7416BDWH

KD7416AWH

Detection area

280

Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight Note 4 Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7416AWH KD7416ADWH KD7416BWH KD7416BDWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 60 kV, Tube current 0.3 to 7.0 mA, Tube voltage 25 to 80 kV, Tube current 0.3 to 7.0 mA, Output 7.5 to 210 W Output 7.5 to 210 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 390 mm, Maximum height: 150 mm (Detection area is shown above.) 420 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 60 m/min, Maximum 5 O 5 to 40 m/min, Maximum 10 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 255 O 260 O 265 O 270 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

KD7417BWH

See page 17 for safer operation.

X-ray Inspection System

Contaminant Inspection System Contaminants in large and wide products can be detected with high sensitivity. Suitable for tall products.

Dust and waterproof Package check Relative mass measurement protection class (Option)

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation (Option)

16 Classifications (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7417BWH

540

KD7417BWH

Belt width

Detection area

880 230 220 390 220 Pass height

420 800 500

340

33.5 dia. Roller

700 to 800 Line heights 1530 to 1630

(8

0)

Effective detection width 390

(650)

450 Leg spacing

60 dia.

(335)

271

755 Leg spacing

Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight Note 4 Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7417BWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 80 kV, Tube current 0.3 to 7.0 mA, Output 7.5 to 210 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 390 mm, Maximum height: 220 mm (Detection area is shown above.) 420 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 40 m/min, Maximum 10 O 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 265 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

23

KD7405ABWH/KD7416ABWH

Suited to unpackaged products, such as meat and fish, with which leakage prevention curtains cannot be used. See page 17 for safer operation.

X-ray Inspection System

B Belt width C D E

W1 Model W1 KD7405ABWH 240 KD7416ABWH 390 W2 200 355

132 1430 1360 Hopper 33.5 dia. Roller 915 to 1015 (KD7405ABWH) 955 to 1055 (KD7416ABWH) 435 1000

Interlock 50 Pass height

1340 to 1355 1268 500

760 to 890

700 to 800 Line heights

450 Leg spacing

60 dia.

650 to 750

I Leg spacing

H

Units: mm

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2, Note 3 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 4 Maximum product weight

Note 5

Power requirements Note 6, Note 7 Mass Environmental conditions Note 8 Protection class Exterior

KD7405ABWH KD7416ABWH Fe sphere and SUS sphere 0.3 mm dia., SUS wire 0.2 mm dia. x 2 mm long Tube voltage 25 to 60 kV, Tube current 0.3 to 7.0 mA, Output 7.5 to 210 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 240 mm, Maximum height: 50 mm Maximum width: 390 mm, Maximum height: 50 mm 270 mm 420 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 5 to 50 m/min, Maximum 5 O 5 to 40 m/min, Maximum 10 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 230 O 280 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The detection area is shown above. Note 3 : The entrance and exit may require covers depending on the length of a product. Note 4 : Variable depending on Product No. Note 5 : Sum total of product weight on the conveyor. Note 6 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 7 : Installing the air-conditioner option changes the displayed power consumption. Note 8 : The air-conditioner option may be required depending on the operating environment.

25 24

700 to 800 Line heights

Effective detection width G

A B C D E F G H I

KD7405ABWH 232 270 265 465 730 1360 to 1460 240 196 605

KD7416ABWH 382 420 340 540 880 60 dia. 450 1530 to 1630 Leg 390 spacing 271 755

F

E

A Belt width B C

A

50

Contaminant Inspection System

Dust and waterproof Package check Relative mass measurement (Option) protection class

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation (Option)

Classifications 10 (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

Terminal FCC compliance switching type (Option)

External Dimensions

KD7405ABWH KD7416ABWH

*The KD7416ABWH uses 16-classification rejection (Option).

KD7405ABWH

Detection area

W2

10 to 15

KD7447DW/KD7447DWE

The system with a maximum detection width of 590 mm can be used for a wide range of packages, e.g. shrink packages and assembly packages in delivery. See page 17 for safer operation.

X-ray Inspection System

(470)

(270)

690

1384

620 Belt width

424

1114

590 (464)

Air Conditioner (Option) Tower Light (Option) 294

1200 500

250 Pass height

49.5 dia. Roller

Line heights

700 to 800

Effective detection width 590 353 980 Leg spacing

836 Leg spacing

30 dia.

Specifications

Model Detection sensitivity Note 1 X-ray output Safety Display Operation method Product size Note 2 Belt width Masking function Missing product detection function Clip check function Preset memory Belt speed Note 3 Maximum product weight

Note 4

Power requirements Note 5, Note 6 Mass Environmental conditions Note 7 Protection class Exterior

KD7447DW KD7447DWE Fe sphere and SUS sphere 0.4 mm dia. Fe sphere and SUS sphere 0.5 mm dia. Tube voltage 25 to 80 kV, Tube current 0.3 to 10.0 mA, Output 7.5 to 350 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel Maximum width: 590 mm, Maximum height: 250 mm (Detection area is shown above) 620 mm Equipped as standard Equipped as standard Equipped as standard Maximum 100 10 to 35 m/min, Maximum 50 O 10 to 40 m/min, Maximum 30 O (However, in an environment where water or oil regularly splashes the equipment, the maximum is 20 O.) 25 to 50 m/min, Maximum 20 O (Option) 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1 kVA, rush current 80 A (typ.) (5 ms or less) 450 O Temperature 0° to 35°C (0° to 40°C with optional air conditioner), relative humidity 30% to 85%, non-condensing IP66 Compliance (for conveyor), IP40 Compliance (for other parts), Tool free belt removal Stainless steel (SUS304)

25 28

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions. Note 2 : The entrance and exit may require covers depending on the length of a product. Note 3 : Variable depending on Product No. Note 4 : Sum total of product weight on the conveyor. Note 5 : Selectable by switching terminals. Note that the rush current shown above is at an AC voltage of 200 V. It varies according to voltage. Note 6 : Installing the air-conditioner option changes the displayed power consumption. Note 7 : The air-conditioner option may be required depending on the operating environment.

1806 to 1906 2100 to 2200

250

Contaminant Inspection System

Dust and waterproof Package check Relative mass measurement protection class

Color LCD touch panel

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line height

Rejection confirmation (Option)

16 Classifications (Option)

Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

FCC compliance Terminal (Option) switching type

External Dimensions

KD7447DW KD7447DWE

KD7447DW

Detection area

410

Units: mm

KD7481AWH/KD7483AWH/KD7483AFWH

Designed to inspect fluid flowing in pipes. See page 17 for safer operation.

X-ray Inspection System

Joint heights

Line heights

Line heights

Joint heights

450 Leg spacing Clamp Union Fittings 2.0 S Clamp Union Fittings 3.0 S

605 Leg spacing

Clamp Union Fittings 3.0 S

560 Leg spacing

Joint heights

Contaminant Inspection System

25 32

Air conditioner is equipped as standard.

Dust and waterproof Package check Relative mass Dust and waterproof measurement protection class protection class

Printer (Option)

Statistics

NG History

Simple cleaning

Flow direction change

Variable belt speed

Variable line heights

Rejection confirmation

16 Classifications Online interface

Ethernet

USB

HACCP Support

CE Marking (Option)

FCC compliance Terminal (Option) switching type

Pipe type

KD7483AFWH

External Dimensions

KD7481AWH KD7483AWH KD7483AFWH

Model

Tower Light (Option)

Tower Light (Option) Stroke width Stroke width Air conditioner

Stroke width Stroke width Air conditioner

1280 Leg spacing

KD7481AWH KD7483AWH

indicates the dimensions of KD7483AWH.

KD7483AFWH

Units: mm

Specifications

Model Detection sensitivity X-ray output Safety Display Operation method

Note 1

Product size Product: solids in fluid Transfer pipe dimension Inspection section pass height Position change at sensitivity adjustment Preset memory Processing capacity (flow) Power requirements Mass Environmental conditions Protection class Exterior Cooling system

KD7481AWH KD7483AWH KD7483AFWH Fe sphere and SUS sphere 0.6 mm dia. (When only water is conveyed) Tube voltage 25 to 60 kV, Tube current 0.3 to 7.0 mA, Output 7.5 to 210 W X-ray leakage: Maximum 1 µSv/h or less, Prevention of X-ray leakage by safety devices 15-inch Color TFT LCD (unified image monitoring screen and operation screen) Touch panel 7 mm or smaller (Less than 1/3 of the minimum height of 12 mm or smaller (Less than 1/3 of the minimum height of the inspection section) the inspection section) 2-inch (50.8 mm) dia. 3-inch (76.2 mm) dia. 20 to 30 mm (variable) 35 mm (fixed) Main unit position change (Pipe position Pipe position change to the front fixed) Maximum 100 5.4 S/ h 11.0 S/ h 100 to 120 Vac ±10%, or 200 to 240 Vac ±10%, single phase, 50/60 Hz, 1.6 kVA 230 O 235 O 340 O Temperature 0° to 40°C, relative humidity 30% to 85%, non-condensing IP66 Compliance (product transfer pipe) Stainless steel (SUS304) Air conditioner (Standard equipment)

Note 1 : Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions.

Information

9 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

866295


You might also be interested in

BETA
D014 D015 Product Support Guide v1.9
Toshiba estudio163-203-165-205 Printer Brochure
3166 CLAMP ON POWER HiTESTER