Read NewLLEmergencyFluorescentBatteryPacks.pdf text version

Emergency

Fluorescent Battery Packs

Family

PSDL

FileName

psdl

Description

Compact fluorescent operation

RevisionDate

09/28/2007

Power Sentry® Battery Packs, Downlighting

Power Sentry® Battery Packs, Linear Fluorescent

PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS 680.143 680.200 ELA-PSMK-PSMKSD-PSDMT-PSRME ELA-RTS-TSPLP-PSTS ELA-RTS-TSPLP-PSTS-PSPRSB PS1400DW PS1400QD PS3000 PS300DW PS300QD PS48 PS600C PS600DW PS600QD PSL400 PSL550 PSL600 PSQ500DW PSQ500QD PSSD PS3000 application guide Lamp/ballast compatibility chart Mounting kits and accessories Remote test switches and pilot lights Remote test switches and pilot lights Specification grade Specification Grade Full light output Economical 2''-4'' lamp operation Economical 2'-4' lamp operation 48V Central battery inverter 2-hour run time 2'-4' lamp operation Economical 2-lamp (2''-4'') or 1-lamp 8'' operation Economical 2-lamp (2'-4') or 1-lamp 8' operation Low Profile 2'-4' lamp operation Low profile, T5 lamp operation Low profile, high lumen output Quick-Mount 2''-4'' lamp operation Quick-Mount 2'-4' lamp operation Inverter self-diagnostics module 09/16/2005 09/09/2005 04/12/2007 05/15/2003 09/02/2008 01/30/2008 02/22/2008 11/15/2007 11/08/2007 02/22/2008 11/08/2007 11/08/2007 11/08/2007 02/22/2008 11/07/2007 11/07/2007 11/07/2007 11/07/2007 02/22/2008 12/27/2007

Catalog Number

Notes

Type

FEATURES

INTENDED USE Factory- or field-install inside or outside (field only) fluorescent fixture to operate lamp(s) at an initial output of 10% to 95% of rated lamp lumens, providing optimum, glare-free illumination for 90 minutes upon interruption of normal power. CONSTRUCTION Black, 20-gauge steel, permanently sealed housing. Dual-voltage input capability (120V or 277V). Polarized quick-connect light/switch assembly simplifies installation (not included on the PSDL1 2LP). Remote test plate with pilot light and test switch standard for PSDL1 2LP. Patent-pending integrated test switch/pilot light that requires only onehole drilling (PSDL3). U.S. Patent No. (PSDL3) 6,522,147. PERFORMANCE PSDL1 operates one two-pin 18W or 26W quad-tube compact fluorescent lamp. PSDL1 2LP operates two (2) two-pin (13-26W) quad-tube fluorescent lamps. PSDL2 operates one two-pin 7W, 9W, or 13W quad-tube compact fluorescent lamp. PSDL3 operates one or two four-pin twin-tube (9­13W), triple-tube (18­42W*), quad-tube (13­26W) or 2D compact fluorescent lamp(s). *42W triple-tube is one lamp only. Low-glare, shadow-free illumination provides excellent visibility for safe building evacuation. BATTERY Sealed, maintenance-free, high-temperature nickel-cadmium battery. Ensures long life over a wide range of temperatures. Polarized battery connector simplifies maintenance and prevents charger damage due to improper connection. Pilot light and test switch provide visual and manual means of monitoring system operation. Automatic battery recharge after 90-minute discharge. ELECTRONIC Constant-current series resistor-type charger. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Unit can be remote mounted up to half the distance recommended by the ballast manufacturer or 50 feet, whichever is less. Optional external mounting tray provides quick and flexible mounting means for most applications. Unit wired into building circuit in two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to the battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.) PSDL3 includes a five-year total customer satisfaction warranty.

UL

R

®

Compact Fluorescent Battery Packs

PSDL

CA UT ION

PSDL1 and PSDL2

PSDL3

ORDERING INFORMATION

For shortest lead times, configure product using standard options (shown in bold). Example: PSDL1

Accessories 2

Order as separate item.

Designation

Options

PSDL1 Bi-pin (18-26W) battery pack PSDL2 Bi-pin (7-13W) battery pack PSDL3 Four-pin (9-42W) battery pack

2LP Two-lamp operation (PSDL1 only)

DL UL listed for damp location1 0o ­ 50o C (32o ­ 122o F)

SD Self-diagnostics1,2

ELA PSDMT External mounting tray ELA RTS Remote test plate with pilot light and test switch (PSDL1 2LP only) ELA TSPLP Remote or replacement test switch/pilot light; mounts up to 25' away from fixture1 ELA TSPLPSD Remote or replacement test switch/pilot light for self-diagnostics; mounts up to 25' away from fixture1

NOTES: Factory installation is available on most Lithonia fixtures. Consult EL downlighting spec sheet for details. Remotes can be mounted up to 25' away from fixture. 1 Only available on the PSDL3. 2 SD option includes the PSSD module and the ELA PSMKSD mounting kit.

PSSD Field-installable self-diagnostics module1,2

ELA PSMKSD Self-diagnostics mounting kit (must be ordered separately to install the PSSD on a PSDL3 product)2

Emergency

Sheet #: PSDL

PSBP-190

PSDL Compact Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

ELECTRICAL

Volts Maximum Amps AC input Watts

PSDL1/PSDL2 PSDL1 2LP PSDL3

PSDL1 PSDL2 PSDL3

3.6 6

3 yrs. 3 yrs.

10 yrs. 10 yrs.

none 3 none 3

32­100°F (0­38°C) 32­100°F (0­38°C)

120 277 120 277 120 277

.275 .255 .27 .27 .27 .25

3.5 3.5 3.5 3.5 3.3 3.2

NOTES: 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

Lamp Compatibility & Emergency Output

Catalog Number Lamp Lamp Base Description

Quad-Tube (2pin) PSDL1/ PSDL2P G23-4

Philips

Osram/ Sylvania

"Dulux D" CF13DD "Dulux D" CF18DD "Dulux D" CF26DD "Dulux S" CF7DS "Dulux S" CF9DS "Dulux S" CF13DS "Dulux D" CF13DD

GE

Lamp Manufac. Initial Lumen Initial Lumens Rating Lamp 1 Lamp 2

* 500

MOUNTING

All dimensions are inches (millimeters). PSDL1 and PSDL2

"PLC Lamps" PL-C 13W/USA 10mm/13W "PLC Lamps" PL-C 18W 10mm/18W "PLC Lamps" PL-C 26W 10mm/26W "PL Lamps" PL -S7W "PL Lamps" PL 9 "PL Lamps" PL13 "PLC Lamps" PL-C 13W/USA 10mm/13W *

"Double Biax" OS-780 GE-810 F13DBX23T4 PL-860 "Double Biax" OS & PL-1250 F18DBXT4 GE-1150 "DoubleBiax" OS & PL-1800 F26DBXT4 GE-1710 "Biax" F7BX "Biax" F9BX "Biax" F13BX OS & PL-4 00 GE- 400 OS-580 GE-600 OS-800 GE-825

Super G24d-2 Compact 10mm Quad-Tube (2-pin) G24d-3

675

650

1-1/2 (38)

925 350 500 650 450

950

2-3/8 (60)

* * * *

PSDL2 Compact Twin-Tube (2-pin)

G23 G23 GX23 Quad-Tube GX23-2 (2pin)

Cross section end view

Length: 10-5/8 (270) Shipping weight: 2.14 lbs. (.90 kgs.)

"Double Biax" OS-780 GE-810 F13DBX23T4 PL-860

PSDL3

Compact Twin-Tube (4-pin)

2G7

"Dulux S/E" CF9DS/E 9W "Dulux S/E" CF13DS/E 13W "Dulux D/E" CF13DD/E/8 13W "Dulux D/E" CF18DD/E/8 18W "Dulux D/E" CF26DD/E/8 26W "Dulux T/E" CF18DT/E/IN/8 18W "Dulux T/E" CF26DT/E/IN/8 26W "Dulux T/E" CF32DT/E/IN/8 32W "Dulux T/E" CF42DT/E/IN/8 42W

*

580

NA

NA

1-11/16 (43)

2GX7

*

*

800

NA

NA

3-3/16 (81)

"Double Biax" F13DBX/4P 900 580 635

PSDL3

Super GX24q-1 Compact Quad-Tube GX24q-2 (4-pin) GX24q-3

"PL Cluster" PL-C 13W/4P 13W "PL Cluster" PL-C 18W/4P 18W "PL Cluster" PL-C 26W/4P 26W "PL Triple" PL-T 18W/4P 18W "PL Triple" PL-T 26W/4P 26W "PL Triple" PL-T 32W/4P 32W "PL Triple" PL-T 42W/4P 42W

Cross section end view

Length: 17-1/8 (435) Shipping weight: 5.0 lbs. (2.3 kgs.)

PSDL1 2LP

"Double Biax" OS & PL-1250 F18DBX/4P GE-1150 "Double Biax" OS & PL-1800 F26DBX/4P GE-1710 "Triple Biax" F18TBX/SPX "Triple Biax" F26TBX/SPX "Triple Biax" F32TBX/SPX 1200

675

750

790

900

Super GX24q-2 Compact GX24q-3

595

615

1800

412

749

Triple-Tube GX24q-3 (4-pin) GX24q-3

OS & PL-2400 GE-2200

657

1038

Cross section end view

948 NA

*

3200

Length: 12 (304) Shipping weight: 3.0 lbs. (1.4 kgs.)

NA = Not Available

Lithonia Lighting

Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com

Sheet #: PSDL

© 1998 Acuity Brands Lighting, Inc., Rev. 9/28/07

Power Sentry Fluorescent Battery Packs

Lamp Compatibility Guide

®

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Lithonia, GA 30012 Phone: 800-334-8694 In Canada: 160 avenue Labrosse., Point-Claire, P.O. H9R 1A1 www.lithonia.com

Emergency

© 2000 Lithonia Lighting, Rev. 6/05

Form No. 680.200

Sheet #: 680.200

ACPS - 130

Catalog Number

Notes

Type

FEATURES & SPECIFICATIONS

INTENDED USE Use when mounting Lithonia Power Sentry PS1400 DW on exterior of a fluorescent fixture. OPERATION Usage of ELA PSMK complies with National Electrical Code provision (NEC 300) that prohibits exposed wiring. CONSTRUCTION Constructed of 20-gauge steel. Adds 3.5 inches maximum to overall module length. Grommeting included to protect wiring from sharp edges of fixture knockout.

Inverter Accessories

ELA PSMK

Remote Mounting Kit

ORDERING INFORMATION

Catalog Number Description

ELA PSMK

Remote mounting kit for PS1400 DW; two required

FEATURES & SPECIFICATIONS

INTENDED USE Use when mounting self-diagnostics module (PSSD) on exterior of a fluorescent fixture. OPERATION Usage of ELA PSMKSD complies with National Electrical Code provision (NEC 300) that prohibits exposed wiring. CONSTRUCTION Constructed of 20-guage steel. Adds 3 inches maximum to overall fixture length. Grommeting included to protect wiring from sharp edges of fixture knockout. Dimensions: 3.04"L x 1.22"H x 1.26" W

Inverter Accessories

ELA PSMKSD

Remote Mounting Kit for Self-Diagnostics

ORDERING INFORMATION

Catalog Number Description

ELA PSMKSD

External mounting kit for self-diagnostics module

Emergency

Sheet #: ELA-PSMK-PSMKSD-PSDMT-PSRME

ACPS - 120

ELA Inverter Accessories FEATURES & SPECIFICATIONS

INTENDED USE Provides simple and fast installation of PSDL1, PSDL2 and PSDL3. CONSTRUCTION External mounting tray. Adjustable bar hanging brackets.

Inverter Accessories

ELA PSDMT

Mounting Tray

ORDERING INFORMATION

Catalog Number Description

ELA PSDMT

External mounting tray for PSDL1, PSDL2 and PSDL3

FEATURES & SPECIFICATIONS

INTENDED USE Provides remote mounting of Power Sentry products in air-rated plenums. OPERATION Compatible with Lithonia Power Sentry Series (PS300, PSQ500, PS600 and PS1400). Complies with National Electrical Code Provision (NEC 300) that prohibits exposed wiring. CONSTRUCTION Constructed of 18-gauge steel, post-painted black. Provides two standard 3/4" conduit knockouts and two 1/2" knockouts for test switch/pilot light mounting. Dimensions: 17" L x 3" W x 2" H

Inverter Accessories

ELA PSRME

Remote Mounting Enclosure

ORDERING INFORMATION

Catalog Number Description

ELA PSRME

Remote mounting enclosure for Power Sentry products (PS300, PSQ500, PS600 and PS1400)

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: ELA-PSMK-PSMKSD-PSDMT-PSRME

© 2002 Acuity Brands Lighting, Inc., Rev. 7/22/08

Catalog Number

SPECIFICATIONS

INTENDED USE Provides remote access to test switch and pilot light for Power Sentry and emergency products from Lithonia Downlighting and Gotham Downlighting. OPERATION Compatible with Lithonia Power Sentry Series. Recommended mounting no more than 25 feet away from the Power Sentry and no more than 25 feet away from emergency downlights. Provides the ability to view the red pilot light and test the emergency operation of the unit without having to open the fixture. CONSTRUCTION Power Plug wire adaptor converts the wires from the emergency unit so they can be fed through conduit or flex (not provided) to the remote test switch/ pilot light. Remote test switch plate includes toggle switch (RTS2 or momentary RTS3) and red pilot light. Plate is white to match most ceiling tiles. Remote test switch plate installs onto a standard single-gang switch box. Mounts in ceiling or wall near emergency fixture.

Notes

Type

Inverter Accessories

ELA RTS

Remote Test Switches/Pilot Lights

ORDERING INFORMATION

Catalog Number Description

ELA RTS2 ELA RTS3

Remote test switch/pilot light for PS3000 Remote test switch pilot light for PS600C, PSL400, PSL550, PSL600 and PSDL1 2LP

SPECIFICATIONS

INTENDED USE Provides remote access to test switch and pilot light for Power Sentry products from Lithonia Fluorescent, Lithonia Downlighting and Gotham Downlighting. Can also be used for replacement part purposes. OPERATION Compatible with Lithonia Power Sentry Series. Recommend mounting no more than 25 feet away from the Power Sentry and no more than 25 feet away from emergency fixture. Provides the ability to view the red pilot light and test the emergency operation of the unit without having to open the fixture. CONSTRUCTION Remote test switch plate includes a red or multi-chromatic pilot light that can be mounted in ceiling or wall near emergency fixture.

Inverter Accessories

ELA TSPLP

Remote or Replacement Test Switch/Pilot Light

Compatible with the PS300, PSQ500, PS600, PS1400 and PSDL3

ORDERING INFORMATION

Catalog Number Description

ELA TSPLP ELA TSPLP SD

Remote or replacement test switch/pilot light (with plenum-rated cable) Remote or replacement test switch/pilot light (with plenum-rated cable) for self-diagnostics1

NOTE: 1 Must order ELA TSPLSD if have self-diagnostics with battery pack. This will give you a multi-chromatic LED needed to perform self-diagnostic testing.

Emergency

Sheet #: ELA-RTS-TSPLP-PSTS

ACPS - 110

ELA

Inverter Accessories

Inverter Accessories

SPECIFICATIONS

INTENDED USE Use with Power Sentry-equipped fluorescent fixtures in tandem-in-line wiring applications. OPERATION Compatible with Lithonia Power Sentry Series (PS300, PS600, PS1400 and PS3000). Provides the ability to test emergency operation of the unit by breaking the AC line voltage conductor. This allows the unit inverter to be tested with wall switch on or off. CONSTRUCTION Double-pole, single-throw test switch. Momentary type switch, normally closed.

ELA PSTS

Test Switch

ORDERING INFORMATION

Catalog Number Description

ELA PSTS

Test switch for PS300, PS600, PS1400 and PS3000

Lithonia Lighting

Acuity Lighting Group, Inc. Emergency Lighting Systems One Lithonia Way, Decatur, GA 30035 Phone: 800-334-8694 In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3 www.lithonia.com

Sheet #: ELA-RTS-TSPLP-PSTS

© 2003 Acuity Lighting Group, Inc., Rev. 05/03

ELA-RTS-TSPLP-PSTS.p65

Catalog Number

SPECIFICATIONS

INTENDED USE Provides remote access to test switch and pilot light for POWER SENTRY and emergency products from Lithonia Lighting Downlighting and Gotham Downlighting. OPERATION Compatible with POWER SENTRY Series. Recommended mounting no more than 25 feet away from the POWER SENTRY and no more than 25 feet away from emergency downlights. Provides the ability to view the red pilot light and test the emergency operation of the unit without having to open the fixture. CONSTRUCTION Power Plug wire adaptor converts the wires from the emergency unit so they can be fed through conduit or flex (not provided) to the remote test switch/pilot light. Remote test switch plate includes toggle switch (RTS2 or momentary RTS3) and red pilot light. Plate is white to match most ceiling tiles. Remote test switch plate installs onto a standard single-gang switch box. Mounts in ceiling or wall near emergency fixture.

Notes

Type

Inverter Accessories

ELA RTS

Remote Test Switches/Pilot Lights

®

ORDERING INFORMATION

Catalog Number Description

ELA RTS2 ELA RTS3

Remote test switch/pilot light for PS3000 Remote test switch pilot light for PS600C, PSL400, PSL550, PSL600 and PSDL1 2LP

SPECIFICATIONS

INTENDED USE Provides remote access to test switch and pilot light for POWER SENTRY products from Lithonia Lighting Fluorescent and Downlighting, and Gotham Downlighting. Can also be used for replacement part purposes. OPERATION Compatible with POWER SENTRY Series. Recommend mounting no more than 25 feet away from the POWER SENTRY and no more than 25 feet away from emergency fixture. Provides the ability to view the red pilot light and test the emergency operation of the unit without having to open the fixture. CONSTRUCTION Remote test switch plate includes a red or multi-chromatic pilot light that can be mounted in ceiling or wall near emergency fixture. Drywall bracket not included.

Inverter Accessories

ELA TSPLP

Remote or Replacement Test Switch/Pilot Light

Compatible with the PS300, PSQ500, PS600, PS1400 and PSDL3

ORDERING INFORMATION

Catalog Number Description

®

ELA TSPLP ELA TSPLP SD

Remote or replacement test switch/pilot light (with plenum-rated cable) Remote or replacement test switch/pilot light (with plenum-rated cable) for self-diagnostics1

NOTE: 1 Must order ELA TSPLSD if have self-diagnostics with battery pack. This will give you a multi-chromatic LED needed to perform self-diagnostic testing.

Emergency

Sheet #: ELA-RTS-TSPLP-PSTS-PSPRSB

ACPS - 110

ELA

Inverter Accessories

Inverter Accessories

SPECIFICATIONS

INTENDED USE Use with Power Sentry-equipped fluorescent fixtures in tandem-in-line wiring applications. OPERATION Compatible with POWER SENTRY Series (PS300, PS600, PS1400 and PS3000). Provides the ability to test emergency operation of the unit by breaking the AC line voltage conductor. This allows the unit inverter to be tested with wall switch on or off. CONSTRUCTION Double-pole, single-throw test switch. Momentary type switch, normally closed.

ELA PSTS

Test Switch

ORDERING INFORMATION

Catalog Number Description

ELA PSTS

Test switch for PS300, PS600, PS1400 and PS3000

®

SPECIFICATIONS

INTENDED USE To enhance the normal mode compatibility of lamp EOL (end of life) protected ballasts. OPERATION Compatible with POWER SENTRY Series (PSQ500, PS600, PS1400 and PSDL3) with quick disconnect (QD) and damp/wet (DW). Do not use with PSSD self-diagnostic module. CONSTRUCTION Compact size, measuring 3.5" x 1.25" x 0.5", to fit within ballast cover wiring compartment.

Inverter Accessories

ELA PSPRSB

Test Switch Interface

ORDERING INFORMATION

Catalog Number Description

ELA PSPRSB Field-installable test switch interface

®

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: ELA-RTS-TSPLP-PSTS-PSPRSB

© 2003 Acuity Brands Lighting, Inc., Rev. 9/2/08

Catalog Number

Notes

Type

FEATURES

INTENDED USE Specification grade emergency ballast to operate one or two lamps (4' or shorter) or one 8' lamp. Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at a reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Black, 20-gauge steel, permanently-sealed housing. Housing provides extra room for wire routing in ballast channel. Dual-voltage input capability (120V or 277V). Polarized quick-connect pilot light/test switch assembly simplifies installation. Patented integrated test switch pilot light that requires only one-hole drilling. Pilot light and test switch provide visual and manual means of monitoring system operation. U.S. Patent No. 6,522,147 and 6,577,136. PERFORMANCE Operates one or two 2' ­ 4' fluorescent T8 ­ T12 lamps, one 2' ­ 4' fluorescent T5, T8, or T12, HO, long compact (biax) or one 6' ­ 8' fluorescent T8 ­ T12 for 90 minutes. Compatible with electronic, rapid start, instant start, slimline, preheat or trigger start ballast in standard or energy-saving configurations. New AC ballasts with EOL (end of life) protection may require EOL accessory to ensure normal AC mode operation. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery pack and switched circuit to fixture ballast). Unit will strike normally off lamp. BATTERY Sealed, maintenance-free, high-temperature nickel-cadmium battery. Ensures long life over a wide range of temperatures. 24-hour battery recharge after 90-minute discharge. External battery connectors allows battery pack to be disabled for maintenance and installation. ELECTRONIC Constant-current series resistor-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Mounts concealed within fixture wireway for clean appearance and protection against vandalism; or mounts on outside of fixture housing if internal space is limited. Two ½" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens. External mounting requires two accessory kits ELA PSMK or factory option MK. Kit adds 6" maximum to overall length. Unique size (13-5/16" L x 2-3/8" W x 1-5/8" H) fits a variety of fluorescent troffers, industrials, commercials and strips. LISTING UL listed. Damp location listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. DW option is UL approved for installation in wet and damp location listed fixtures. (Note: DW option does not make the battery pack suitable for mounting outside the fixture in a wet location application.) WARRANTY Five-year warranty.

Fluorescent Battery Packs

PS1400 DW

ORDERING INFORMATION

PS1400

Designation PS1400 Battery pack

Lead times will vary depending on options selected. Consult with your sales representative. Example: PS1400 DW SD

Accessories*

Order as separate item.

Options MK External mounting kit DW UL approved for use in wet and damp location listed fixtures 050oC (32-122oF). 120V 50Hz 120V, 50Hz input 220V 50Hz 220 or 240V, 50Hz input 240V 60Hz 240V, 60Hz input SD Self-diagnostics 1

ELA TSPLP ELA TSPLPSD ELA PSMK ELA PSMKSD ELA PSRME PSSD ELA PSPRSB

Remote or replacement test switch pilot light; mounts up to 25' away from fixture Remote or replacement test switch pilot light for selfdiagnostics; mounts up to 25' away from fixture External mounting kit; two required External mounting kit for self-diagnostics module Remote mounting enclosure Field-installable self-diagnostics module Field-installable interface for enhanced compatability with lamp EOL protection ballast2

NOTE: 1 Self-diagnostics (PSSD) module ships with fluorescent battery pack. See PSSD Inverter Accessories specification sheet for details on self-diagnostics module. 2 ELA PSPRSB accessory not required with self-dianostics option (SD).

* See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PS1400 DW

PSBP-170

PS1400 Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

6.0

3 years

10 years

none3

32­100°F 1-5/8 (40)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. Damp location models are UL listed 0-50oC (32-122oF). 3 Periodic system status test recommended.

ELECTRICAL

Volts Maximum AC input Amps Watts

2-3/8 (60)

120 277

.27 .25

3.3 3.2

Cross section end view

Length: 13-5/16 (338mm) Shipping weight: 4 lbs. (2.3 kgs.)

LAMP COMPATIBILITY

Lamp Type 24" - 48" T5 24" - 48" T5HO U-Lamp T8 24" ­ 48" T8 60" ­ 96" T8 Circline T9 U-Lamp T12 24" ­ 48" T12 60" ­ 96" T12 24" ­ 48" HO T12 60" ­ 96" HO T12 24" ­ 48" VHO T12 60" ­ 96" VHO T12 Twin-Tube (4-pin) Quad-Tube (4-pin) Twin-Tube (4-pin) Triple-Tube (4-pin) Triple -Tube (4-pin) 2D Wattage 14 ­ 28 24 ­ 54 16 ­ 31 17 ­ 32 40 ­ 59 20 ­ 40 34 ­ 40 20 ­ 40 50 ­ 75 35 ­ 60 70 ­ 110 74 ­ 115 135 ­ 215 9 ­ 13 13 ­ 26 18 ­ 55 18 ­ 32 42 28-38 Emergency Operation

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-lamp emergency operation for 2 ­ 4 lamp ballasts.

LUMEN OUTPUT

PS1400DW Initial Lumen Output

Lamp One lamp Two lamps

KEY FEATURES

1422 NC 1294 NC NC NC

KEY OPTIONS

F32T8 CF40 FBO31T8 F96T8HO F28T5 F54T5

1453 920 1319 1595 890 940

NC = Not compatible

Initial lumen output measured at 25°C ambient temperature. External fixture mounting ELA PSMK or factory option MK (two required) Polarized quick-connect Self-diagnostics module

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers , GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS1400 DW

©1998 Acuity Brands Lighting, Inc., Rev.1/30/08

Catalog Number

Notes

Type

FEATURES

INTENDED USE Specification-grade fluorescent battery pack operates one or two lamps (4' or shorter) or one 8' lamp. Factory or field installed within fluorescent fixture ballast channel. Upon interruption of normal power battery pack automatically strikes and operates lamps at reduced light output, providing glare-free illumination for 90 minutes. CONSTRUCTION Durable thermoplastic/metal housing resists impact, scratches, and corrosion. UL-94V-0 flame rating. Reduced-profile footprint fits in the tightest applications. Polarized quick-connect pilot light/test switch assembly simplifies installation. Pilot light and test switch provide visual and manual means of monitoring system operation. U.S. Patent No. 6,522,147. PERFORMANCE Lamp selector switch optimizes single or dual lamp performance. Operates one or two 2' ­ 4' fluorescent T8 ­ T12 lamps, one 2' ­ 4' fluorescent T5, T8, or T12, HO, long compact (biax) or one 6' ­ 8' fluorescent T8 ­ T12 for 90 minutes. Compatible with T8 and T5 electronic, T12 magnetic, instant start, rapid start, and slimline ballasts. New AC ballasts with EOL (end of life) protection may require EOL accessory (ELA PSPRSB) to ensure normal AC mode operation. BATTERY Sealed, maintenance-free, high-temperature nickel-cadmium battery. Ensures long life over a wide range of temperatures. Automatic battery recharge after 90-minute discharge. Fully charged after 72 hours. ELECTRONIC Dual-voltage input capability (120V or 277V). Constant current-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Patent-pending Quick-Disconnect connector system allows for quick and easy replacements at end of life without rewiring. Mounts concealed within fixture wireway for clean appearance and protection against vandalism; or mounts on outside of fixture housing if internal space is limited. Two 1/2" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens.

1400 Lumen Reduced-Profile Fluorescent Battery Packs

PS1400QD

External mounting requires a remote mounting enclosure (ELA PSRME). Compact size (13-5/16" L x 2-3/16" W x 1-3/16" H) fits in a variety of fluorescent fixtures: troffers, volumetric recessed, industrials, commercials and strips. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. Unit mounting centers are identical to a standard ballast. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. See PS1400DW specification sheet for product UL approved for use in wet and damp location fixtures. WARRANTY Five-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

ORDERING INFORMATION

PS1400QD

Series

For shortest lead times, configure product using standard options (shown in bold). Example: PS1400QD SD

Accessories4

Order as separate item.

Options

ELA TSPLP ELA TSPLPSD ELA PSMKSD ELA PSRME ELA PSPRSB

PS1400QD Battery pack

SD

Self-diagnostics1,2,3

NOTES: 1 Self-diagnostics (PSSD) module ships separately. See PSSD Inverter Accessories spec sheet for details on self-diagnostics. 2 Compatible with lamp EOL protection ballasts. 3 ELA PSPRSB not required with SD option. 4 See Inverter Accessories specification sheets for details on other compatible devices.

Remote or replacement test switch pilot light; mounts up to 25' away from fixture Remote or replacement test switch pilot light for selfdiagnostics; mounts up to 25' away from fixture External mounting kit for self-diagnostics module Remote mounting enclosure Field-installabe interface for enhanced compatibility with lamp EOL protection ballasts3

PSSD Field-installable self-diagnostics module

Emergency

Sheet #: PS1400QD

PSBP-165

PS1400QD Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

2-3/16 (59)

Cross section end view

Length: 13-5/16 inches Shipping weight: 2.0 lbs (0.68 kg).

1-3/16 (29)

9.4

3 years

10 years

none 3

32­100°F

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

RECOMMENDED SPACING

One Footcandle Average Spacing Guidelines PS1400QD

2GT8 3 32 2SP8 3 32 2PM3N 3 32 2AV 3 32 2PMO 3 32

ELECTRICAL

Volts Maximum AC input Amps Watts

120 277

.27 .29

3.3 3.2

Open Office Corridor 2x4 Open Office

47 47 26 58

47 57 47 54

45 53 38 49

47 59 47 53

33* 43 26* 47

LAMP COMPATIBILITY

Lamp Type 24" - 48" T5 24" - 48" T5HO U-Lamp T8 24" ­ 48" T8 60" ­ 96" T8 Circline T9 U-Lamp T12 24" ­ 48" T12 60" ­ 96" T12 24" ­ 48" HO T12 60" ­ 96" HO T12 24" ­ 48" VHO T12 60" ­ 96" VHO T12 Twin-Tube (4-pin) Quad-Tube (4-pin) Twin-Tube (4-pin) Triple-Tube (4-pin) Triple -Tube (4-pin) 2D Wattage 14 ­ 28 24 ­ 54 16 ­ 31 17 ­ 32 40 ­ 59 20 ­ 40 34 ­ 40 20 ­ 40 50 ­ 75 35 ­ 60 70 ­ 110 74 ­ 115 135 ­ 215 9 ­ 13 13 ­ 26 18 ­ 55 18 ­ 32 42 28-38 Emergency Operation

Corridor 2x2

* Limited spacing due to 40:1 max/min ratio requirement by NFPA 101.

Open Office Spacing

1 FC average 0.1 FC min. 45' 9'

PS1400QD Initial Lumen Output Table

Lamp Tested 1 Lamp 2 Lamps F32T8 1453 1422 CF40 920 NC FBO31T8 1319 1294 F96T8HO 1595 NC F28T5 890 NC F54T5 940 NC NC = Not compatible Initial lumen output measured at 25°C ambient temperature.

6'

Fluorescent Battery Pack: PS1400QD Fluorescent Fixture: 2x4 Parabolic Lamp Type: F32T8 Meets Life Safety Code standard minimum illuminance of 0.1FC and average illuminance of 1.0 FC. Assumes 3 T8 lamps in each fixture, 6-foot wide path of egress, ceiling height 9' and reflectances of 80/50/20.

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-lamp emergency operation for 2 ­ 4 lamp ballasts.

KEY FEATURES

Typical Power Sentry

KEY OPTIONS

1-1/2" 1-3/16"

SELF-D MODULEIAGNOSTICS

2-3/8"

2-3/16"

New Quick-Disconnect wiring system

New reduced-profile design fits in the tightest of applications

Self-diagnostics module

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS1400QD

©1998 Acuity Brands Lighting, Inc., Rev.2/22/08

Catalog Number

Notes

Type

FEATURES

INTENDED USE Designed for applications requiring full light output. Field installed inside or outside fluorescent fixture to operate lamp(s) at an initial output of 95 percent of rated lamp lumens, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION 20-gauge, black steel housing. Dual-voltage input capability (120V or 277V). PERFORMANCE Operates one or two 2' ­ 4' fluorescent T8 ­ T12 lamps, one 2' ­ 4' fluorescent T5, T5HO, T8, T12, HO, VHO, long compact (biax) or one 6' ­ 8' fluorescent (T8 ­ T12) for 90 minutes. Compatible with electronic, rapid-start, instant-start, slimline, preheat or trigger start ballasts in standard or energy-saving configurations. Protects against partial or isolated power outages. Low-glare, shadow-free illumination provides excellent visibility for safe building evacuation. Unit wires two ways: on night-light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery pack and switched circuit to the fixture ballast). Unit will strike "normally off" lamp. BATTERY Sealed, maintenance-free, high-temperature nickel cadmium battery. Ensures long life over wide temperature ranges. Battery automatically recharges after a 90-minute discharge. External battery connectors allow battery pack to be disabled for maintenance and installation. Pilot light and test switch provide visual and manual means of monitoring system operation. Two 1/2" holes are required to permit mounting of pilot light/test switch in fixture housing. ELECTRONIC Constant current series resistor-type charger, provides high efficiency and reliable operation. High efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. INSTALLATION Mounts concealed within the plenum or on top of fixture housing for improved aesthetics and protection from vandalism. Wiring protected by 18" flexible conduit. Remote mounting requires accessory kit ELA PSDMT. Battery pack may be remote mounted up to 50 feet from fixture or half the distance recommended by the AC ballast manufacturer, whichever is less. Test switch may be remote mounted up to eight feet from fixture. Order accessory ELA RTS2. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY Five-year total customer satisfaction warranty. See Product Selection Guide for complete details.

Fluorescent Battery Packs

PS3000

ORDERING INFORMATION

PS3000

Designation

For shortest lead times, configure product using standard options (shown in bold). Example: PS3000

Accessories*

Order as separate catalog numbers.

PS3000 Battery pack

ELA RTS2 Remote test switch; mounts up to 25' away from fixture ELA PSDMT External mounting tray

* See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PS3000

PSBP-180

PS3000 Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel Cadmium

Voltage 14.4 Shelf life1 3 years Expected life1 10 years Maintenance none2 Optimum temperature3 32-100oF

MOUNTING

All dimensions are inches (millimeters).

Notes: 1 At 77°F. 2 Periodic system status test recommended. 3 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity.

ELECTRICAL

Maximum AC input Volts 120 277 Amps .092 .041 Watts 9.6 10.19 Power Factor .900 .905 Cross section end view Length: 15-3/8 (391mm) Shipping weight: 10.3 lbs (4.7 kg)

LAMP COMPATIBILITY

Lamp/Ballast Type 24-48" T5 24-48" T5HO U-Lamp T8 24-48" T8 60-96" T8 Circline T9 U-Lamp T12 24-48" T12 60-96" T12 24-48" HO T12 60-96" HO T12 24-48" VHO T12 60-96" VHO T12 Quad Tube (4-pin) 12-24" Twin Tube (4-pin) Triple Tube (4-pin) Wattage 14-28 24-54 16-31 16-31 40-59 20-40 34-40 20-40 50-75 35-60 70-110 74-115 135-215 13-26 18-50 26-32

Light output data based on one 32W T8 lamp. Two-lamp operation evenly divides output between the lamps for better distribution of emergency illumination. Light output of other lamp types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult Lithonia representative for further information.

Emergency Operation

PERFORMANCE

Emergency Lamp Lumen Output

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-lamp emergency operation for 2 ­ 4 lamp ballasts.

KEY FEATURES

Remote Mounting with the ELA PSDMT Accessory Kit

Remote Test Switch

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS3000

©1996 Acuity Brands Lighting, Inc., Rev. 11/15/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Engineering-grade charcoal white polycarbonate housing resists impact, scratches and corrosion. UL94V-0 flame rating. Space-saving housing provides extra room for wire routing in ballast channel. Nylon wire management clips facilitate ballast cover replacement. Dual-voltage input capability (120V or 277V). Patent-pending integrated test switch pilot light that requires only one-hole drilling. PERFORMANCE Operates one 2' ­ 4' fluorescent lamp for 90 minutes. Compatible with electronic, rapid-start, slimline, preheat or trigger-start ballasts in standard or energy-saving configurations. Protects against partial or isolated power outages. Low-glare, shadow-free illumination provides excellent visibility for safe building evacuation. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitch circuit to battery charger and switch circuit to the fixture ballast). BATTERY Sealed, maintenance-free, high-temperature nickel cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Two 1/2" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens. Mounting centers are identical to a standard ballast. Compact size (9-1/2" L x 2-1/2" W x 1-5/8" H) fits a variety of fluorescent troffers, industrials, commercials and strips. LISTING UL listed. Meets UL 924, NFPA 101 (Current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. DW option is UL approved for installation in wet and damp location listed fixtures. (Note: DW option does not make the battery pack suitable for mounting outside the fixture in wet location applications.) WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

Fluorescent Battery Packs

PS300

ORDERING INFORMATION

PS300

Designation PS300 Battery pack DW

Lead times will vary depending on options selected. Consult with your sales representative. Example: PS300

Accessories2

Order as separate items.

Options UL approved for use in wet and damp location listed fixtures 0-50°C (32-122°F)1

ELA TSPLP Remote or replacement test switch pilot light. Mounts up to 25' away from fixture. ELA PSRME Remote mounting enclosure. *See Inverter Accessories specification sheets for details on other compatible devices.

Factory installation is available on most Lithonia Lighting fixtures. Consult Fluorescent Sheet EL for details.

Emergency

Sheet#: PS300

PSBP-100

PS300 Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

4.8

3 years

7­9 years

none 3

32­100°F 1-5/8 (41)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. Damp location models are UL listed 0-50oC (32-122oF). 3 Periodic system status test recommended.

ELECTRICAL

Volts Maximum AC input Amps Watts

2-1/2 (64)

Cross section end view

Length: 9-1/2 (241) Shipping weight: 1.4 lbs. (0. 6 kgs.)

120 277

.28 .25

2.5 2.5

LAMP COMPATIBILITY

Lamp Type U-Lamp T8 24" ­ 48" T8 Circline T9 U-Lamp T12 24" ­ 48" T12 Biax Twin Tube (4-pin) Wattage 16 ­ 31 17 ­ 32 20 ­ 40 34 ­ 40 20 ­ 40 18 ­ 40 Emergency Operation

PERFORMANCE

Emergency Lamp Lumen Output

One-lamp emergency operation for 1 ­ 4 lamp ballasts.

Light output data based on F32 T8 lamps (2800 lamp lumen rating). Two-lamp, energy-saving, rapid-start ballast. Thermal and ballast factor corrections have been included. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual luminance levels. Consult with a Lithonia Lighting representative for further information.

KEY FEATURES

Unique space-saving housing.

Polarized quick-connect integrated test switch pilot light assembly

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS300

©1998 Acuity Brands Lighting, Inc., Rev. 11/8/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Engineering-grade charcoal gray plastic housing resists impact, scratches and corrosion. UL94V-0 flame rating. Low-profile, contoured housing design. Dual-voltage input capability (120V or 277V). Patented integrated test switch pilot light that requires only one-hole drilling. U.S. Patent No. 6,522,147. PERFORMANCE Operates one 2' ­ 4' fluorescent lamp for 90 minutes. Compatible with most electronic, rapid start, slimline, preheat or trigger start ballasts in standard or energy-saving configurations. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitch circuit to battery charger and switch circuit to the fixture ballast). BATTERY Sealed, maintenance-free, high-temperature nickel cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION New Quick-Disconnect wiring harness provides easy replacement capabilities. Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Two ½" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens. Mounting centers are identical to a standard ballast. Compact size (9.5" L x 2.19" W x 1.18" H) fits a variety of fluorescent troffers, industrials, commercials and strips. Reduces profile design.

Fluorescent Battery Packs

PS300QD

LISTING UL listed. Meets UL 924, NFPA 101 (Current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. See PSW300DW specification sheet for product that is UL approved for use in wet- and damp-location fixtures. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

ORDERING INFORMATION

PS300QD

Designation

For shortest lead times, configure product using standard options (shown in bold). Example: PS300QD

Accessories1

Order as separate items.

PS300QD

Reduced-profile battery pack with Quick Disconnect

ELA TSPLP Remote or replacement test switch pilot light. Mounts up to 25' away from fixture. ELA PSRME Remote mounting enclosure.

NOTES: 1 See Inverter Accessories specification sheets for details on other compatible devices.

Factory installation is available on most Lithonia Lighting fixtures. Consult Fluorescent Sheet EL for details.

Emergency

Sheet#: PS300QD

PSBP-95

PS300QD Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

2-3/16 (59)

2.4

3 years

7­9 years

none 3

32­100°F

1-3/16 (29)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

Cross section end view

Length: 9-1/2 (241) Shipping weight: 1.4 lbs. (0. 6 kgs.)

ELECTRICAL

Volts Maximum AC input Amps Watts

120 277

.27 .29

2.5 2.5

LAMP COMPATIBILITY

Lamp Type U-Lamp T8 24" ­ 48" T8 Circline T9 U-Lamp T12 24" ­ 48" T12 Biax Twin Tube (4-pin) Wattage 16 ­ 31 17 ­ 32 20 ­ 40 34 ­ 40 20 ­ 40 18 ­ 40 Emergency Operation

One-lamp emergency operation for 1 ­ 4 lamp ballasts.

KEY FEATURES

New Quick-Disconnect wiring system

Polarized quick-connect integrated test switch pilot light assembly

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS300QD

©1998 Acuity Brands Lighting, Inc., Rev. 2/22/08

Catalog Number

Notes

Type

FEATURES

INTENDED USE For factory or field installation for 90 minutes of emergency operation using a 48 VDC central battery supply such as telephone exchanges and other facilities that have dedicated systems. CONSTRUCTION 22-gauge black steel housing. Dual-voltage input capability (120/277V). PERFORMANCE Provides 90 minutes of emergency lighting to existing fluorescent fixtures operated with a 48 VDC central battery supply. Detects AC power loss and automatically converts to DC power. Compatible with electronic, rapid start, instant start, slimline, preheat or trigger start ballasts in standard or energy saving configurations. BATTERY Requires 48 VDC power source. Recommended emergency operation not to exceed 90 minutes. ELECTRONIC Consists of a solid-state inverter, EMI filter, AC voltage-sensitive circuit and switch circuit in one compact case. Constant-current series resistor-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency, push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Compact size (9.4" L x 2.4" W x 1.5" H) allows installation in a variety of fluorescent troffers, industrials, commercials and strips. Fast, easy installation simplified by a "user friendly" wiring diagram. Unit can be remote mounted up to half the distance recommended by the ballast manufacturer or 50 feet, whichever is less. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. WARRANTY One-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

Fluorescent Emergency Ballast

PS48

ORDERING INFORMATION

PS48

Designation PS48 48-volt emergency ballast

Lead times will vary depending on options selected. Consult with your sales representative. Example: PS48

NOTE: Factory installation is available on most Lithonia fluorescent fixtures. Consult EL sheet for details.

Emergency

Sheet #: PS48

PSBP-200

PS48 Fluorescent Emergency Ballast

SPECIFICATIONS

ELECTRICAL

Volts Maximum AC input Amps Watts

MOUNTING

All dimensions are inches (millimeters).

120 277

.28 .09

3.5 .5

1.5 (38)

LAMP COMPATIBILITY

Lamp Type U-Lamp T8 24" ­ 48" T8 U-Lamp T12 24" ­ 48" T12 60" ­ 96" T12 60" ­ 96" HO T12 60" ­ 96" VHO T12 Biax Twin-Tube (4-pin) 2D lamps 60" T8 Wattage 16 ­ 31 17 ­ 32 34 ­ 40 20 ­ 40 50 ­ 75 70 ­ 110 135 ­ 215 18 ­ 50 28 ­ 38 40 Emergency Operation

2.4 (60)

Cross section end view

Length: 9.4 (238) Shipping weight: 2.5 lbs. (1 kg.)

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-hour emergency operation for one lamp. Two-lamp emergency operation for 2 ­ 4 lamp ballasts.

PERFORMANCE

The PS48 provides full lumen output for 90 minutes in the emergency mode. The lumen output is determined by the particular lamp being utilized, not the emergency ballast. Two-lamp operation evenly divides the output between the lamps for better distribution of emergency illumination.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS48

©1998 Acuity Brands Lighting, Inc., Rev. 11/8/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Specifically designed for 2-hour run time. Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at an initial output of 20 % of rated lamp lumens, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION 22-gauge black steel housing. Dual-voltage input capability (120/277V). PERFORMANCE Operates one 2' ­ 4' fluorescent T8 or T12 lamp for 120 minutes. Compatible with electronic, rapid start, instant start, preheat or trigger-start ballasts in standard or energy-saving configurations. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. Produces 600 to 700 lumens initial emergency light output. BATTERY Sealed, maintenance-free, high-temperature, nickel-cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after a 120-minute discharge. Pilot light and test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant-current series resistor-type charger. Capacitive input circuit provides high-efficiency and reliable operation. High-efficiency, push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Two ½" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens. Compact size (9.4" L x 2.4" W x 1.5" H) allows installation in a variety of fluorescent troffers, industrials, commercials and strips. Fast, easy installation simplified by a "user friendly" wiring diagram. Unit can be remote mounted up to half the distance recommended by the ballast manufacturer or 50 feet, whichever is less. LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Meets North Carolina Dept. of Insurance requirements. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

INVE RTER /CHA RG

CA

Fluorescent Battery Packs

PS600C

ER

ON UTI

ORDERING INFORMATION

PS600C

Designation PS600C Battery pack

Lead times will vary depending on options selected. Consult with your sales representative. Example: PS600C

Accessories

Order as separate items.

ELA PSRME Remote mounting enclosure ELA RTS3 Remote test switch pilot light ELA PSMK External mounting kit

NOTE: Factory installation is available on most Lithonia fluorescent fixtures. Consult EL sheet for details.

Emergency

Sheet #: PS600C

UL

R

PSBP-160

PS600C Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

3.6

3 years

7­10 years

none 3

32­100°F (0­38°C) 1.5 (38)

Notes: 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 120 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

2.4 (60)

ELECTRICAL

Volts Maximum AC input Amps Watts

Cross section end view

Length: 9.4 (238) Shipping weight: 2.5 lbs. (1 kg.)

120/277

.28

3.5

LAMP COMPATIBILITY

Lamp Type 24" ­ 48" T12 24" ­ 48" T8 Wattage 20 ­ 40 17 ­ 32 Emergency Operation

PERFORMANCE

Emergency Lamp Lumen Output

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-hour emergency operation for one lamp.

Light output data based on F032T8 or F40T12 lamps. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult a Lithonia representative for further information.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS600C

©1998 Acuity Brands Lighting, Inc., Rev. 11/8/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Specification grade emergency ballast to operate one or two lamps (4' or shorter) or one 8' lamp. Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Engineering-grade white polycarbonate housing resists impact, scratches and corrosion. UL94V-0 flame rating. Space-saving housing provides extra room for wire routing in ballast channel. Polarized quick-connect pilot light/test switch assembly simplifies installation. Dual-voltage input capability (120V or 277V). Patent pending integrated test switch pilot light that requires only one-hole drilling. U.S. Patent No. 6,522,147. PERFORMANCE Operates one or two 2' ­ 4' fluorescent T8 ­ T12 lamps, one 2' ­ 4' fluorescent, HO, VHO, long compact (biax) lamp or one 6' ­ 8' fluorescent T8 ­ T12 lamp for 90 minutes. Compatible with electronic, rapid start, instant start, slimline, preheat or trigger start ballasts in standard or energy-saving configurations. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. BATTERY Sealed, maintenance-free, high-temperature nickel-cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Two ½" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens.

Fluorescent Battery Packs

PS600 DW

Compact size (9-1/2" L x 2-1/2" W x 1-1/2" H) allows installation in a variety of fluorescent troffers, industrials, commercials and strips. Unit mounting centers are identical to a standard ballast. LISTING UL listed. Damp location listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. DW option is UL approved for installation in wet and damp location listed fixtures. (Note: DW option does not make the battery pack suitable for mounting outside the fixture in a wet location application.) WARRANTY Five-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide.)

ORDERING INFORMATION

Lead times will vary depending on options selected. Consult with your sales representative. Example: PS600 DW SD

PS600

Designation PS600 Battery pack DW Options UL approved for use in wet and damp location listed fixtures 0-50oC (32-122oF) Self-diagnostics 1 ELA TSPLP ELA TSPLPSD ELA PSRME ELA PSMKSD PSSD

Accessories*

Order as separate items.

SD

Remote or replacement test switch pilot light; Mounts up to 25' away from fixture Remote or replacement test switch pilot light for selfdiagnostics; Mounts up to 25' away from fixture Remote mounting enclosure External mounting kit for self-diagnostics module Field-installable self-diagnostic module

NOTE: 1 Self-diagnostics (PSSD) module ships with fluorescent battery pack. See PSSD Inverter Accessory spec sheet for details on self-diagnostics module.

* See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PS600DW

PSBP-150

PS600 DW Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

10.8

3 years

7­9 years

none3

32­100°F

1-1/2 (38)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. Damp location models are UL listed 0-50oC (32-122oF). 3 Periodic system status test recommended.

ELECTRICAL

Volts Maximum AC input Amps Watts

2-1/2 (64)

Cross section end view

Length: 9-1/2 (241) Shipping weight: 1.8 lbs. (0. 8 kgs.)

120 277

.27 .26

2.2 2.2

LAMP COMPATIBILITY

Lamp Type 24 ­ 48" T5 U-Lamp T8 24" ­ 48" T8 60" ­ 96" T8 Circline T9 U-Lamp T12 24" ­ 48" T12 60" ­ 96" T12 24" ­ 48" HO T12 60" ­ 96" HO T12 24" ­ 48" VHO T12 60" ­ 96" VHO T12 24" ­ 48" T5HO Long Compact (4-pin) Wattage 14 ­ 28 16 ­ 31 17 ­ 32 40 ­ 59 20 ­ 40 34 ­ 40 20 ­ 40 50 ­ 75 35 ­ 60 70 ­ 110 74 ­ 115 135 ­ 215 24 ­ 54 18 ­ 50 Emergency Operation

PERFORMANCE

Emergency Lamp Lumen Output

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-lamp emergency operation for 2 ­ 4 lamp ballasts.

Light output data based on two F40 CW lamps (3050 lamp lumen rating). Two-lamp energy-saving rapid start ballast. Thermal and ballast factor corrections have been included. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult Lithonia Lighting represenative for further information.

KEY FEATURES

KEY OPTIONS

Unique space-saving housing.

Polarized quick-connect, integrated test switch/pilot light assembly.

Self-diagnostics module.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Bldg. 3 Conyers , GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PS600DW

©1994 Acuity Brands Lighting, Inc., Rev. 11/8/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Specification grade fluorescent battery pack operates one or two lamps (4' or shorter) or one 8' lamp. Factory or field installed within fluorescent fixture ballast channel. Upon interruption of normal power, battery pack automatically strikes and operates at reduced light output, providing optimum glarefree illumination for 90 minutes. CONSTRUCTION Durable thermoplastic/metal housing resists impact, scratches and corrosion. UL94V-0 flame rating. Reduced-profile footprint fits in the tightest applications. Polarized quick-connect pilot light/test switch assembly simplifies installation. Pilot light and test switch provide visual and manual means of monitoring system operation. U.S. Patent No. 6,522,147. PERFORMANCE Operates one or two 2' ­ 4' fluorescent T8 ­ T12 lamps, one 2' ­ 4' fluorescent T5, T8, or T12, HO, long compact (biax) lamp or one 6' ­ 8' fluorescent T8 ­ T12 lamp for 90 minutes. Compatible with T8 and T5 electronic, T12 magnetic, instant start, rapid start, and slimline ballasts. BATTERY Sealed, maintenance-free, high-temperature nickel-cadmium battery ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Fully charged after 72 hours. ELECTRONIC Dual-voltage input capability (120V or 277V). Constant current-type charger. Capacitive input circuit provides high efficiency and reliable operation. High-efficiency push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Patent-pending QUICK DISCONNECT connector system allows for quick and easy replacements at end of life without rewiring (not available with DW option). Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Two ½" holes in fixture channel permit mounting of test switch/pilot light behind fixture lens. Compact size (9.4" L x 2.19" W x 1.18" H) fits in a variety of fluorescent fixtures: troffers, volumetric recessed, industrials, commercials and strips. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. Unit mounting centers are identical to a standard ballast.

600 Lumen Reduced-Profile Fluorescent Battery Pack

PS600QD

LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. The DW option is UL approved (0-50°C) for installation in wet and damp location listed fixtures. See PSW600DW specification sheet for product that is UL approved for use in wet- and damp-location fixtures. WARRANTY Five-year total customer satisfaction warranty.

ORDERING INFORMATION

PS600QD

Designation Options

For shortest lead times, configure product using standard options (shown in bold). Example: PS600QD SD

Accessories2

Order as separate items.

PS600QD Reduced-profile battery pack with Quick Disconnect

SD

Self-diagnostics

1

ELA TSPLP Remote or replacement test switch pilot light; Mounts up to 25' away from fixture ELA TSPLPSD Remote or replacement test switch pilot light for self-diagnostics; Mounts up to 25' away from fixture ELA PSRME Remote mounting enclosure ELA PSMKSD External mounting kit for self-diagnostics module

PSSD Field-installable self-diagnostic module

NOTES: 1 Self-diagnostics (PSSD) module ships separately. See PSSD Inverter Accessory spec sheet for details on self-diagnostics module. 2 See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PS600QD

PSBP-145

PS600QD Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

2-3/16 (59)

4.8

3 years

7­9 years

none 3

32­100°F

1-3/16 (29)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

Cross section end view

Length: 9.40 inches Shipping weight: 1.5 lbs (0.68 kg).

ELECTRICAL

Volts Maximum AC input Amps Watts

RECOMMENDED SPACING

One Footcandle Average Spacing Guidelines PS600QD

2GT8 3 32 2SP8 3 32 2PM3N 3 32 2AV 3 32 2PMO 3 32

120/277

.29

3.0

Open Office 2x4

32 40

35 43

34 53

26 34

35 40

LAMP COMPATIBILITY

Lamp Type 24-48" T5 24-48" T5HO U-Lamp T8 24"-48" T8 60"-96" T8 24"-48" T12 24"-48" T12HO Long Compact (4-pin) Wattage 14-28 24-54 16-31 17-32 40-59 20-40 35-60 18-50

Emergency Operation

Nominal Initial Lumen Output 1 540 629 TBD 632 TBD 645 401 687

Corridor 2x4

Open Office 2x2 Corridor 2x2

32

33

29

29

28

39

40

35

29

28

Corridor Spacing

1 FC average 0.1 FC min. 43'

Fluorescent Battery Pack: PS600QD Fluorescent Fixture: Lensed Troffer Lamp Type: F32T8

Meets Life Safety Code standard minimum illuminance of 0.1FC and average illuminance of 1.0FC. Assumes 3 T8 lamps in each fixture, 8'Wx100'L corridor, 6-foot wide path of egress, ceiling height 9' and reflectances of 80/50/20.

One-lamp emergency operation for 1 ­ 4 lamp ballasts. Two-lamp emergency operation for 2 ­ 4 lamp ballasts. Tested and approved lamp/ballast combinations. Consult Lithonia Lighting representative for additional lamp/ballast combination compatibility not shown. Notes: 1 Initial lumen output is impacted by multiple variables including fixture type, lamp type, and ambient temperature.

9' 6'

KEY FEATURES

Typical Power Sentry

KEY OPTIONS

1.50" 1.18"

SELF-DIA MODULE GNOSTIC S

2.40"

2.19"

New Quick-Disconnect wiring system

New reduced-profile design fits in the tightest of applications.

Self-diagnostics module.

Lithonia Lighting

Sheet #: PS600QD

©2003 Acuity Brands Lighting, Inc., Rev. 2/22/08

One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Catalog Number

Notes

Type

FEATURES

INTENDED USE For factory or field installation in T8 or T12 fixtures requiring low profile ballast and wireways. Provides 90 minutes of emergency operation at reduced light levels. CONSTRUCTION 22-gauge steel, low-profile housing (1.0"H x 1.5"W) works in conjunction with a slim AC ballast to convert new or existing low-profile fixtures into emergency lighting. Dual-voltage input capability (120V or 277V). PERFORMANCE Operates most 16W-40W (2'-4') T8, T10 or T12 fluorescent lamps without integral starters, including U-shaped, energy saving, and (4-pin) compacts. Compatible with most one, two, three or four-lamp electronic, standard, energy-saving and dimming AC ballasts. Battery pack wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Battery pack will strike "normally off" lamp. Produces 350-450 lumens initial emergency light output. BATTERY Sealed, maintenance-free, high-temperature, nickel-cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. High-efficiency, push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Low-profile size (14.1"L x 1.5"W x 1.0"H) allows mounting in lighting fixtures with limited space inside fixture wireway for clear appearance and protection against vandalism. Mounting centers 13.7". Test switch and pilot light included.

PSL 400

Low-Profile Fluorescent Battery Packs

PSL400

LISTING UL Listed. Meets UL 924, NFPA 101 (Current Life Safety Code), NEC and OSHA illumination standards.\ WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide).

ORDERING INFORMATION

PSL400

Designation PSL400 Low-profile battery pack

Lead times will vary depending on options selected. Consult with your sales representative. Example: PSL400

Accessories*

Order as separate item.

ELA RTS3 Remote test switch pilot light

* See Inverter Accessories specification sheets for details other compatible devices.

Emergency

Sheet #: PSL400

PSBP-110

PSL400 Low-Profile Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

3.6

3 years

7­9 years

none 3

32­100°F

1-1/2" (38)

1.0" (25)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

Cross section end view

Length: 14.1" (358) Shipping weight: 1.9 lbs. (0.9 kgs.)

ELECTRICAL

Volts Maximum AC input Amps Watts

PERFORMANCE

Emergency Lamp Lumen Output

120 277

.1 .1

1.5 1.5

L 450 U M 350 E N 250 S 10 20 30 40 50 60 MINUTES 70 80 90

LAMP COMPATIBILITY

Lamp Type U-Lamp T8 24" ­ 48" T8 U-Lamp T12 24" ­ 48" T12 Compact fluorescent (4-pin) Wattage 16 ­ 31 17 ­ 32 34 ­ 40 20 ­ 40 16 ­ 40

Light output data based on F32T8 lamps (2800 lamp lumen rating). Two-lamp, electronic, rapid-start ballast. Thermal and ballast factor corrections have been included. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult Lithonia representative for further information.

PSL400 INITIAL LUMEN OUTPUT TABLE

Lamps Tested F40T12 FO32T8 PL-T32W/4P, DULUX T/E 32W PL-L 36W, DULUX L 39W, F39/36BX/4P F40T12/ES (34W) Lumens 350 450 400 450 350

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSL400

©2000 Acuity Brands Lighting, Inc., Rev. 11/7/07

Catalog Number Notes Type

FEATURES

INTENDED USE For field or factory installation in T5, T5HO and T8 fixtures utilizing low-profile ballast and wireways. Provides 90 minutes of emergency operation at a reduced light level. CONSTRUCTION Galvanized steel, low-profile housing works in conjunction with low-profile or standard size electronic ballasts to convert new or existing standard or high output T5 fluorescent fixtures into emergency lighting. Dual-voltage input capability (120V or 277V). PERFORMANCE Operates one 14-28W standard or 24-54W high output T5; one 32W(4'), 40W(5') and 44W HO(4') T8 fluorescent lamp; or one 36-55W (4-pin) long compact fluorescent lamp. Compatible with most one, two, three or fourlamp electronic, standard, energy-saving and dimming AC ballasts. Battery pack wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Battery pack will strike "normally off" lamp. Produces 390-700 lumens initial emergency light output. BATTERY Sealed, maintenance-free, high-temperature, nickel-cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and single-pole test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. High-efficiency, push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Low-profile size (18.5"L x 1.18"W x 1.15"H) allows mounting in lighting fixtures with limited space inside fixture wireway for clear appearance and protection against vandalism. Mounting centers 18.1". Test switch and pilot light included. LISTING UL Listed. Meets UL 924, NFPA 101 (Current Life Safety Code), NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide).

550

Low-Profile Fluorescent Battery Packs

PSL550

PSL

ORDERING INFORMATION

PSL550

Designation PSL550 Low-profile battery pack for standard and high-output T5 lamps and 4' T8 lamps

Lead times will vary depending on options selected. Consult with your sales representative. Example: PSL550

Accessories*

Order as separate item.

ELA RTS3 Remote test switch pilot light

* See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PSL550

PSBP-120

PSL550 Low-Profile Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

1.15" (29.2)

3.6

3 years

7­9 years

none 3

32­100°F

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

1.18"(30)

Cross section end view Length: 18.5" (470) Shipping weight: 2.3 lbs.

ELECTRICAL

Volts Maximum AC input Amps Watts

120 277

.18 .18

3.2 3.2

LAMP COMPATIBILITY

Lamp Type T5 T5 HO T8 T8 HO Long Compact (4-pin) Wattage 14 - 28 24 - 54 32(4') - 40(5') 44(4') 36 - 55

PSL550 INITIAL LUMEN OUTPUT TABLE

Lamps Tested FP54, F54T5/HO FP39, F39T5/HO FP24, F24T5/HO FP28, F28T5 FP21, F21T5 FP14, F14T5 F32T8 (4') F40T8 (5') F48T8/HO (4') (44W) PL-L 50W, F50BX/RS, Dulux L 55W PL-L 40W, F40/30BX/RS, Dulux L 40W PL-L 36W, F39/36BX/RS, Dulux L 36W Lumens 700* 620* 390* 700* 620* 430* 635* 570* 470* 510* 625* 610*

* Initial lumen output measured at 25oC ambient temperature.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSL550

© 2001 Acuity Brands Lighting, Inc., Rev. 11/7/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE For field or factory installation in T5, T5HO, T8, T8HO and long-compact fixtures utilizing low-profile ballast and wireways. Provides 90 minutes of emergency operation at a reduced light level. CONSTRUCTION Galvanized steel, low-profile housing works in conjunction with low-profile or standard size electronic ballasts to convert new or existing standard or high output T5 and T8 fluorescent fixtures into emergency lighting. Dual-voltage input capability (120V or 277V). PERFORMANCE Operates one 14-28W standard or 24-54W high output T5; one 17-40W standard or 44-55W high output T8; or one 36-55W (4-pin) long compact fluorescent lamp. Compatible with most one, two, three, or four-lamp electronic, standard, energy-saving and dimming AC ballasts. Battery pack wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to battery charger and switched circuit to the fixture ballast). Battery pack will strike "normally off" lamp. Produces 600-1325 lumens initial emergency light output. BATTERY Sealed, maintenance-free, high-temperature, nickel-cadmium battery. Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Pilot light and single-pole test switch provide visual and manual means of monitoring system operation. ELECTRONIC Constant current-type charger. High-efficiency, push-pull inverter is the most effective method of converting DC power to AC power. It provides maximum light output, battery life and reliability. INSTALLATION Low-profile size (21.5"L x 1.18"W x 1.18"H) allows mounting in lighting fixtures with limited space inside fixture wireway for clear appearance and protection against vandalism. Mounting centers 21.1". Test switch and pilot light included. LISTING UL Listed. Meets UL 924, NFPA 101 (Current Life Safety Code), NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide).

PSL

Low-Profile Fluorescent Battery Packs

PSL600

600

ORDERING INFORMATION

PSL600

Designation PSL600 Low-profile battery pack for standard and high-output T5 and T8 lamps

Lead times will vary depending on options selected. Consult with your sales representative. Example: PSL600

Accessories*

Order as separate item.

ELA RTS3 Remote test switch pilot light * See Inverter Accessories specification sheets for details on other compatible devices.

Emergency

Sheet #: PSL600

PSBP-130

PSL600 Low-Profile Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

1.18" (30)

8.4

3 years

7­10 years

none 3

32­100°F

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

1.18"(30)

Cross section end view Length: 21.5" (546.1) Shipping weight: 3.3 lbs.

ELECTRICAL

Volts Maximum AC input Amps Watts

120 277

.18 .18

3.0 3.0

LAMP COMPATIBILITY

Lamp Type T5 T5 HO T8 T8 HO Long Compact (4-pin) Wattage 14 - 28 24 - 54 17 - 40 44 - 55 36 - 55

PSL600 INITIAL LUMEN OUTPUT TABLE

Lamps Tested FP54, F54T5/HO FP39, F39T5/HO FP24, F24T5/HO FP28, F28T5 FP21, F21T5 FP14, F14T5 F32T8 (4') F40T8 (5') F48T8/HO (4') (44W) PL-L 50W, F50BX/RS, Dulux L 55W PL-L 40W, F40/30BX/RS, Dulux L 40W PL-L 36W, F39/36BX/RS, Dulux L 36W Lumens 1250* 1125* 725* 1325* 1025* 750* 1100* 1325* 1100* 1050* 925* 900*

* Initial lumen output measured at 25oC ambient temperature.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSL600

© 2001 Acuity Brands Lighting, Inc., Rev. 11/7/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Patented labor saving design installs in 15 minutes or less, especially designed for field installation. Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Labor-saving design ­ 1/3 fewer wires and fewer connections than typical fluorescent power packs. Engineering-grade white Lexan polycarbonate housing is impact-resistant, corrosion-resistant and scratch-resistant. UL94-0 flame rating. Space-saving housing provides extra room to route wire in ballast channel. U.S. Patent No. 5,814,971 and 6,522,147. Patent pending integrated test switch pilot light that requires only one-hole drilling. PERFORMANCE Operates one 2'- 4' or U-shaped fluorescent lamp for 90 minutes. (Compatible with electronic T8 and magnetic T12, instant start, rapid start and slimline ballasts). BATTERY Sealed, maintenance-free, high-temperature nickel cadmium battery. Ensures long life over a wide range of temperatures. Automatic battery recharge after 90-minute discharge. ELECTRONIC Dual-voltage input capability (120V or 277V). Additional input lead provided to allow switching of fixture. Constant-current type charger. High-efficiency push-pull inverter is the most effective method of converting DC power. It provides maximum light output, battery life and reliability. INSTALLATION Push-nuts and insulation-displacement connectors reduce installation time. Custom, one-piece test switch/pilot light allows for mounting flexibility. Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Compact size (9-1/2" L x 2-1/2" W x 1-1/2" H) allows installation in a variety of fluorescent fixtures: troffers, industrials, commercials and strips. Unit mounting centers are identical to a standard ballast. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to the battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp. LISTING UL listed. Damp location listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. DW option is UL approved for use in wet and damp location listed fixtures. (Note: DW option does not make the battery pack suitable for mounting outside the fixture in a wet location application.) WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty page in Product Selection Guide).

Fluorescent Battery Packs

PSQ500 DW

ORDERING INFORMATION

Lead times will vary depending on options selected. Consult with your sales representative. Example: PSQ500 DW SD

PSQ500

Designation PSQ500 Battery pack Options DW UL approved for use in wet and damp location listed fixtures 0-50oC (32-122oF) 120V 50Hz 120 volts; 50 hertz1 220-240V 50 Hz 220 or 240 volts; 50 hertz1 220-240V 60 Hz 220 or 240 volts; 60 hertz1 SD Self-diagnostics 2 ELA TSPLP ELA TSPLPSD ELA PSRME ELA PSMKSD PSSD

Accessories*

Order as separate item.

Remote or replacement test switch/pilot light; mounts up to 25' away from fixture Remote or replacement test switch/pilot light for self diagnostics; mounts up to 25' away from fixture Remote mounting enclosure* External mounting kit for self-diagnostics module Field-installable self-diagnostic module

* See Inverter Accessories specification sheets for details on other compatible devices.

NOTES: 2 Self-diagnostics (PSSD) module ships with fluorescent battery pack. See PSSD Inverter Accessories spec sheet for details on self-diagnostics. 1 Damp location standard.

Emergency

Sheet #: PSQ500

PSBP-140

PSQ500 DW Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

3.6

3 years

7­9 years

none 3

32­100°F 1-1/2 (38)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. Damp location models are UL listed 0-50oC (32-122oF). 3 Periodic system status test recommended.

ELECTRICAL

Volts Maximum AC input Amps Watts

2-1/2 (64)

Cross section end view

Length: 9-1/2 (241) Shipping weight: 1.4 lbs. (0.6 kgs.)

120 277

0.27 0.25

2.9 2.5

PERFORMANCE

LAMP COMPATIBILITY

Lamp/Ballast Type 24"- 48" T12 (magnetic) U-Lamp T12 (magnetic) U-Lamp T8 (electronic) 24"- 48" T8 (electronic) 48" T12 (magnetic) Long Compact (4-pin) Wattage 34 ­ 40 34 ­ 40 16 ­ 31 17 ­ 32 32 ­ 40 18 ­ 40 Emergency Operation

550

Emergency Lamp Lumen Output

One-lamp emergency operation. Tested and approved lamp/ballast combinations. Consult Lithonia Lighting representative for additional lamp/ballast combination compatibility not shown.

250

Light output data based on F32T8 lamps (2800 lamp lumen rating). Two-lamp electronic instant start ballast. Thermal and ballast factor corrections have been included. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult Lithonia Lighting representative for further information.

KEY FEATURES

KEY OPTIONS

Polarized quick-connect integrated test switch pilot light assembly.

Pushnuts and insulation displacement connectors reduce installation time.

Self-diagnostics module.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Bldg 3, Conyers , GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSQ500

©1999 Acuity Brands Lighting, Inc., Rev. 11/7/07

Catalog Number

Notes

Type

FEATURES

INTENDED USE Patented labor saving design installs in 15 minutes or less, especially designed for field installation. Factory or field installed inside or outside (field only) fluorescent fixture to operate lamp(s) at reduced light output, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. CONSTRUCTION Labor-saving design ­ 1/3 fewer wires and fewer connections than typical fluorescent power packs. Engineering-grade charcoal gray plastic housing is impact-resistant, corrosion-resistant and scratch-resistant. UL94-0 flame rating. U.S. Patent No. 6,522,147. Patented integrated test switch pilot light that requires only one-hole drilling. PERFORMANCE Operates one 2'- 4' or U-shaped fluorescent lamp for 90 minutes. (Compatible with most electronic T8 and magnetic T12, instant start, rapid start and slimline ballasts). BATTERY Sealed, maintenance-free, high-temperature nickel cadmium battery. Ensures long life over a wide range of temperatures. Automatic battery recharge after 90-minute discharge. ELECTRONIC Dual-voltage input capability (120V or 277V). Additional input lead provided to allow switching of fixture. Constant-current type charger. High-efficiency push-pull inverter is the most effective method of converting DC power. It provides maximum light output, battery life and reliability. INSTALLATION New Quick-Disconnect wiring harness provides easy replacement capabilities. Push-nuts and insulation-displacement connectors reduce installation time. Custom, one-piece test switch/pilot light allows for mounting flexibility. Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Compact size (9.5" L x 2.5" W x 1.18" H) allows installation in a variety of fluorescent fixtures: troffers, industrials, commercials and strips. Unit mounting centers are identical to a standard ballast. Unit wires two ways: on night light circuit (permanently energized) or on switchable circuit (unswitched circuit to the battery charger and switched circuit to the fixture ballast). Unit will strike normally off lamp.

Fluorescent Battery Packs

PSQ500QD

LISTING UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Standard unit is UL approved for installation in sealed and gasketed fixtures. See PSW600DW specification sheet for product that is UL approved for use in wet- and damp-location fixtures. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty page in Product Selection Guide).

ORDERING INFORMATION

PSQ500QD

Designation Options

For shortest lead times, configure product using standard options (shown in bold). Example: PSQ500QD SD

Accessories2

Order as separate item.

ELA TSPLP ELA TSPLPSD ELA PSRME ELA PSMKSD

PSQ500QD Battery pack

SD

Self-diagnostics1

Remote or replacement test switch/pilot light; mounts up to 25' away from fixture Remote or replacement test switch/pilot light for selfdiagnostics; mounts up to 25' away from fixture Remote mounting enclosure External mounting kit for self-diagnostics module

PSSD

NOTES: 1 Self-diagnostics (PSSD) module ships separately. See PSSD Inverter Accessories spec sheet for details on self-diagnostics. 2 See Inverter Accessories specification sheets for details on other compatible devices.

Field-installable self-diagnostic module

Emergency

Sheet #: PSQ500QD

PSBP-135

PSQ500QD Fluorescent Battery Packs

SPECIFICATIONS

BATTERY Sealed Nickel-Cadmium

Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2

MOUNTING

All dimensions are inches (millimeters).

2-3/16 (59)

2.4

3 years

7­9 years

none 3

32­100°F

1-3/16 (29)

Notes: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended.

Cross section end view

Length: 9-1/2 (241) Shipping weight: 1.4 lbs. (0.6 kgs.)

ELECTRICAL

Volts Maximum AC input Amps Watts

PERFORMANCE

Emergency Lamp Lumen Output

120 277

0.27 0.29

2.5 2.5

550

LAMP COMPATIBILITY

Lamp/Ballast Type 24"- 48" T12 (magnetic) U-Lamp T12 (magnetic) U-Lamp T8 (electronic) 24"- 48" T8 (electronic) 48" T12 (magnetic) Long Compact (4-pin) Wattage 34 ­ 40 34 ­ 40 16 ­ 31 17 ­ 32 32 ­ 40 18 ­ 40 Emergency Operation

250

One-lamp emergency operation. Tested and approved lamp/ballast combinations. Consult Lithonia Lighting representative for additional lamp/ballast combination compatibility not shown.

Light output data based on F32T8 lamps (2800 lamp lumen rating). Two-lamp electronic instant start ballast. Thermal and ballast factor corrections have been included. Light output for other lamp and ballast types will vary. Luminaire efficiency and application conditions must be determined to calculate actual illuminance levels. Consult Lithonia Lighting representative for further information.

KEY FEATURES

KEY OPTIONS

New Quick-Disconnect wiring system

Pushnuts and insulation displacement connectors reduce installation time.

Self-diagnostics module.

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSQ500QD

©1999 Acuity Brands Lighting, Inc., Rev. 2/22/08

Catalog Number

Notes

Type

FEATURES & SPECIFICATIONS

INTENDED USE Designed to perform self-diagnostic testing for five minutes every month and thirty minutes every six months. May be factory- or field-installed as part of the test switch/pilot light assembly with the PSQ500QD, PS600QD, PS1400QD and PSDL3. CONSTRUCTION AND OPERATION Single multi-chromatic status indicator and audible beep to display threestate charging, test activation and four-state diagnostic status. Audible beep can be permanently deactivated in the field. Patent pending test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of AC to DC transfer, charging and battery condition. Continuously monitors AC functionality. Automatic testing is easily postponed for eight hours by activating manual test switch. U.S. Patent No. 6,522,147; 6,577,136 INSTALLATION Low profile, lightweight design (1.1" H X 1.1" W X 5.6" L). Easily mounts within the fixture wireway. Screw slot located on top of module to insure module is secure. May be mounted on back of fixture with ELA PSMKSD (wire cover) accessory. WARRANTY Five-year warranty.

SELF-D MODULEIAGNOSTIC S

Inverter Accessories

PSSD

SELF-DIAGNOSTICS MODULE

Compatible with PSQ500QD, PS600QD, PS1400QD and PSDL3

ORDERING INFORMATION

Catalog Number Description

PSSD PSSD DW ELA PSMKSD

Self-diagnostics module for PSQ500, PSQ500QD, PS600, PS600QD, PS1400, PS1400QD and PSDL3. Self-diagnostics module for PSQ500 DW, PS600 DW, PS1400 DW and PSDL3 DW. DW version is UL approved for use in wet and damp location listed fixtures 0o-50oC. External mounting kit for self-diagnostics module.1

NOTE: 1 ELA PSMKSD is standard component with PSDL3 SD.

Emergency

Sheet #: PSSD

ACPS-100

PSSD Inverter Accessory COMPATIBILITY

Fluorescent Battery Packs Compatible with Self-Diagnostics Module

Product PSQ500 or PSQ500QD PS600 or PS600QD PS1400 or PS1400QD PSDL3 Series 11 or 20 13 or 20 13 or 20 11 Field-Installed After Jan-01 After Dec-00 After Dec-00 After Jan-02 Factory-Installed After Jan-02 After Feb-01 After Feb-01 After Jan-02

DIAGNOSTIC KEY

CONDITION

Normal mode Self-testing Emergency mode Insufficient charge Battery pack failure Emergency lamp failure PSSD module failure Over/under charge

STATUS INDICATION

Steady green Flashing green Off

=

Flashing red/green Single-flash red Double-flash red Triple-flash red Quadruple-flash red

KEY FEATURES

Lithonia Lighting

Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com

Sheet #: PSSD

© 2002 Acuity Brands Lighting, Inc., Rev. 12/27/07

Information

44 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

9560


You might also be interested in

BETA
Power Sentry Techsheets_ORIGINAL LAYOUT.indd