Read Advanced%20Digital%20Cable%20Low%20Voltage%20Catalog.pdf text version

COAXIAL CABLES

BROADBAND CATV COAXIAL CABLES 2-7 DBS CABLES 8 75 PRECISION VIDEO COAXIAL CABLES 9-11 SECURITY CCTV CABLES 12-16 50 RF 17 LOW LOSS 50 RF 18-19 50 RF MIL TYPE 20 NETWORK COAXIAL & TWINAXIAL CABLES 21 DATA & COMPUTER NETWORK CABLES 22 INDUSTRIAL TWINAXIAL DATA CABLES 23

FIRE ALARM CABLES

FIRE ALARM CABLES - FPLR 25 FIRE ALARM CABLES - FPLP 26 FIRE ALARM CABLES - FPLR DATA GRADE 27 FIRE ALARM CABLES - FPLP DATA GRADE 28 FIRE ALARM - NPLF 29 FIRE ALARM CABLES - NYC LOCAL LAW 5 30

MULTI-CONDUCTOR & SECURITY CABLES

SECURITY ALARM CABLES 32-35 COMMUNICATION & CONTROL CABLES 36-38

WATER-RESISTANT CABLES

REPEL BRAND COMMUNICATION CABLES 40-42 REPEL BRAND COAXIAL CABLES 43

SPECIALTY CABLES

PREMIUM AUDIO CABLES 45 CATEGORY 5E 350 MHz CABLES 46 CATEGORY 6E 550 MHz CABLES 47 HOME AUTOMATION CABLES 48 LANDSCAPE CABLES 49

REFERENCE INFORMATION

TECHNICAL INFORMATION 50-55 COMPETITOR CROSS REFERENCE 56-60 PART NUMBER INDEX 61-62

Gen-X is Advanced Digital Cable's solution to the Market's demand for enhanced cables. The Gen-X brand of cables have

been designed and manufactured with Quality as the top priority. Advanced Digital Cable's technical expertise has been utilized to develop and perfect its cables to meet the needs of increasingly complex and demanding sound and security systems. Many of the Gen-X cables are stocked in Hayesville, North Carolina and in a variety of put-ups. A system failure or loss of continuity can be disastrous on any size job. That's why you need Gen-X cables, which were designed to meet the highest quality standards and unsurpassed reliability. Whether you need extra bandwidth, extra bonding or extra flexibility, Gen-X brand cables are the choice for you.

BROADBAND CATV COAXIAL CABLES

BROADBAND CATV COAXIAL CABLES 2-7 DBS CABLES 8 75 PRECISION VIDEO COAXIAL CABLES 9-11 SECURITY CCTV CABLES 12-16 50 RF 17 LOW LOSS 50 RF 18-19 50 RF MIL TYPE 20 NETWORK COAXIAL & TWINAXIAL CABLES 21 DATA & COMPUTER NETWORK CABLES 22 INDUSTRIAL TWINAXIAL DATA CABLES23

BROADBAND CATV COAXIAL CABLES

RG 6

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

75 83% 16.2 53.1 See Chart Page 50

RG 6 18 AWG Solid .040" BCCS 40% AL Braid Shield Black PVC Jacket 4-4069

80oC CATV CM 18 AWG (solid) .040" BCCS 28.0/M' 91.9/km .180 FPE 4.57 Bond-X AL Foil + AL Braid 40% Shield Coverage 9.0/M' 29.5/km .270 6.86

RoHS

RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket CATV 18 AWG .180 4.57 Bond-X AL .270 6.86 4-4061

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket With .047" Galvanized Steel Messenger 18 AWG .180 4.57 Bond-X AL .270 6.86 75 83% 16.2 53.1 See Chart 4-4061M CATV

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km Page 50

RoHS

RG 6 Dual 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket 18 AWG .180 4.57 Bond-X AL .270 6.86 75 4-4061D CATV

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km x .590 x 14.99

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BCCS 90% AL Braid Shield Black PVC Jacket CATV 18 AWG .180 4.57 Bond-X AL .270 6.86 4-4060

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 90% Shield Coverage 5.0/M' 16.4/km

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BCCS 95% BC Braid Shield Black PVC Jacket 18 AWG .180 4.57 BC Braid .270 6.86 4-4106A CATV

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE 95% Shield Coverage

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BC 95% BC Braid Shield Black PVC Jacket 18 AWG .180 4.57 BC Braid .270 6.86 4-4006A CATV

CM 80oC (solid) .040" BC 28.0/M' 91.9/km FPE 95% Shield Coverage

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BCCS Quad Shield Black PVC Jacket 18 AWG .180 4.57 Bond-X AL .298 4-4061QS CATV

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 40% + 60% Shld Coverage 4.8/M' 15.7/km

7.57

75

83%

16.2

53.1

See Chart Page 50

RoHS

2

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES CATV COAXIAL CABLES BROADBAND

RG 6

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

53.1 See Chart Page 50

RG 6 Direct Burial 18 AWG Solid .040" BCCS 60% AL Braid Shield Black Polyethylene Jacket 18 AWG .180 4.57 Bond-X AL .270 6.86 75 83% 16.2 4061PE

80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km

RoHS

RG 6 18 AWG Solid .040" BC 60% TC Braid Shield Black PVC Jacket 18 AWG .180 4.57 Bond-X AL .270 6.86 4-4068TC CM

80oC (solid) .040" BC 6.4/M' 21.0/km FPE Foil +TC Braid 60% Shield Coverage 5.6/M' 18.4/km

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 RISER 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket 18 AWG .180 4.57 AL Foil + .270 6.86 75 4-4061R CATVR

CMR 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE AL Braid 60% Shield Coverage 9.0/M' 29.5/km

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 RISER 18 AWG Solid .040" BC 95% TC Braid Shield Black PVC Jacket CMR 18 AWG .180 4.57 AL Foil + .270 6.99 75 2106R

75oC (solid) .040" BC 6.4/M' 21.0/km FPE TC Braid 95% Shield Coverage 2.8/M' 9.2/km

83%

16.2

53.1

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BC 2 x 98% BC Braid Shield Black PVC Jacket 18 AWG .180 4.57 Bond-X AL .288 7.32 4-4006DB CM

80oC (solid) .040" BC 7.5/M' 24.6/km FPE Foil + 2 x BC Braid 98% Shld Coverage 2.0/M' 6.6/km

75

83%

17.3

56.7

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 90% AL Braid Shield White Low Smoke PVC Jacket CATVP 18 AWG .170 4.30 AL Foil + .230 5.84 75 84% 15.8 8-9070

CL2P 75oC (solid) .040" BC FFEP AL Braid 90% Shield Coverage

51.8

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 60% AL Braid Shield White Low Smoke PVC Jacket CATVP 18 AWG .170 4.30 AL Foil + .230 5.84 75 84% 15.8 8-9071

CL2P 75oC (solid) .040" BC FFEP AL Braid 60% Shield Coverage

51.8

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BCCS 90% AL Braid Shield White Low Smoke PVC Jacket CATVP 18 AWG .170 4.30 AL Foil + .230 5.97 75 84% 16.3 8-9170

CMP 75oC (solid) .040" BCCS 28.0/M' 91.9/km FFEP AL Braid 90% Shield Coverage 5.0/M' 16.4/km

53.5

See Chart Page 50

RoHS

5

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

3

BROADBAND CATV COAXIAL CABLES

RG 6

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

RG 6 PLENUM 18 AWG Solid .040" BCCS 60% AL Braid Shield White Low Smoke PVC Jacket CATVP 18 AWG .170 4.32 AL Foil + .230 5.97 75 84% 16.3 8-9171

CMP 75oC (solid) .040" BCCS 28.0/M' 91.9/km FFEP AL Braid 60% Shield Coverage 9.0/M' 29.5/km

53.5

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 60% + 40% AL Braid Shields White Low Smoke PVC Jacket 18 AWG .170 4.32 AL Braid .248 6.30 75 83% 16.3 53.5 8-9068QS CATVP

CMP 75oC (solid) .040" BC 28.0/M' 91.9/km FFEP 60% + 40% Shields Coverage 4.8/M' 15.7/km

See Chart Page 50

RG 6 PLENUM 18 AWG Solid .040" BC 95% BC Braid Shield White Low Smoke PVC Jacket 18 AWG .170 4.32 BC Braid .233 5.92 75 84% 16.3 8-9006A CATVP

CMP 75oC (solid) .040" BC 28.0/M' 91.9/km FFEP 95% Shield Coverage 6.4/M' 21.0/km

53.5

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 95% TC Braid Shield White Low Smoke PVC Jacket CMP 18 AWG .170 4.32 AL Foil + .234 5.94 75 84% 16.2 8-9106

SDI/HDTV Digital Video 75oC (solid) .040" BC 6.4/M' 21.0/km FFEP TC Braid 95% Shield Coverage 2.8/M' 9.2/km

53.1

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 65% TC Braid Shield White Low Smoke PVC Jacket 8-9068TC

75oC CMP 18 AWG (solid) .040" BC 6.4/M' 21.0/km .170 FFEP 4.32 AL Foil + TC Braid 65% Shield Coverage 5.1/M' 16.7/km .222 5.64 75 82% 16.3 53.5 See Chart Page 50

RoHS

4

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES CATV COAXIAL CABLES BROADBAND

RG 59

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

RG 59 20 AWG Solid .032" BCCS 40% AL Braid Shield Black PVC Jacket CATV 20 AWG .144 3.66 Bond-X AL .240 6.02 4-4590

80oC (solid) .032" BCCS 44.5/M' 146.0/km FPE Foil + AL Braid 40% Shield Coverage 17.0/M' 55.8/km

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 59 20 AWG Solid .032" BCCS 67% AL Braid Shield Black PVC Jacket CATV 20 AWG .146 3.71 Bond-X AL .242 6.15 4-4591

80oC (solid) .032" BCCS 44.5/M' 146.0/km FPE Foil + AL Braid 67% Shield Coverage

75

83%

16.2

53.2

See Chart Page 50

RoHS

RG 59 22 AWG Solid .032" BCCS 53% AL Braid Shield Black PVC Jacket CATV 22 AWG .140 3.55 Bond-X AL .240 6.02 4-4599

80oC (solid) .025" BCCS 54.0/M' 177.2/km FPE Foil + AL Braid 53% Shield Coverage

75

83%

16.2

53.2

See Chart Page 50

RoHS

7

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

5

BROADBAND CATV COAXIAL CABLES

RG 11

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

16.1 52.8

1 10 50 100 200 400 700 900 1000 .2 .4 .9 1.3 1.9 2.9 4.1 4.8 5.2 .6 1.1 3.0 4.3 6.2 9.5 13.5 15.7 17.1

RG 11/U 14 AWG Solid .064" BC 97% BC Braid Shield Black Polyethylene Jacket 14 AWG .285 7.24 BC Braid .405 10.29 75 84% 4011PE

80oC (solid) .064" BC 2.6/M' 8.5/km FPE 97% Shield Coverage 1.1/M' 3.6/km

RoHS

RG 11/U 14 AWG Solid .064" BC 97% BC Braid Shield Black PVC Jacket CM 14 AWG .285 7.24 BC Braid .405 10.29 4-4011

80oC (solid) .064" BC 2.6/M' 8.5/km FPE 97% Shield Coverage 1.1/M' 3.6/km

75

84%

16.1

52.8

RoHS

1 10 50 100 200 400 700 900 1000

.2 .4 .9 1.3 1.9 2.9 4.1 4.8 5.2

.6 1.1 3.0 4.3 6.2 9.5 13.5 15.7 17.1

RG 11/U 14 AWG Solid .064" BCCS 60% AL Shield Black PVC Jacket CATV 14 AWG .280 7.11 Bond-X AL .400 10.16 4-4111

CM 80oC (solid) .064" BCCS 11.0/M' 36.1/km FPE Foil + AL Braid 60% Shield Coverage 4.1/M' 13.4/km

75

83%

16.2

53.1

See Chart Page 50

RoHS

RG 11/U 14 AWG Solid .064" BCCS 60% AL Shield Black Polyethylene Jacket 14 AWG .280 7.11 Bond-X AL .400 10.16 75 4111PE

80oC (solid) .064" BCCS 11.0/M' 36.1/km FPE Foil + AL Braid 60% Shield Coverage 4.1/M' 13.4/km

83%

16.2

53.1

See Chart Page 50

RoHS

6

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES CATV COAXIAL CABLES BROADBAND

RG 11 Plenum

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

83% 16.3 53.5 See Chart Page 50

PLENUM RG 11 14 AWG Solid .064" BC 95% BC Shield White PVDF Jacket CMP 14 AWG .274 6.96 BC Braid .348 8.84 75 7-9011

150oC (solid) .064" BC 2.6/M' 8.5/km FFEP 95% Shield Coverage

RoHS

PLENUM RG 11 14 AWG Solid .064" BC 60% AL Shield White PVDF Jacket CMP 14 AWG .274 6.96 Bond-X AL .348 8.84 75 7-9012

150oC (solid) .064" BC 2.6/M' 8.5/km FFEP Foil + AL Braid 60% Shield Coverage 3.8/M' 12.5/km

83%

16.3

53.5

See Chart Page 50

RoHS

PLENUM RG 11 14 AWG Solid .064" BCCS 60% AL Shield White PVDF Jacket CATVP 14 AWG .274 6.96 Bond-X AL .348 8.84 75 7-9112

CMP

150oC

RoHS

(solid) .064" BCCS 11.0/M' 36.1/km

FFEP

Foil + AL Braid 60% Shield Coverage 3.9/M' 12.8/km

83%

16.3

53.5

See Chart Page 50

PLENUM RG 11 14 AWG Solid .064" BC 60% + 40% AL Shield White PVDF Jacket 14 AWG .280 7.1 Bond-X AL .380 9.65 75 83% 7-9012QS CATVP

CMP

150oC

RoHS

(solid) .064" BC 2.6/M' 8.5/km

FFEP

Foil + AL Braid 60% + 40% Shield Coverage

15.8

51.8

See Chart Page 50

PLENUM RG 11 14 AWG Solid .064" BCCS 60% + 40% AL Shield White PVDF Jacket 14 AWG .280 7.1 Bond-X AL .380 9.65 75 83% 7-9112QS CATVP

CMP

150oC

RoHS

(solid) .064" BCCS 11.0/M' 36.1/km

FFEP

Foil + AL Braid 60% + 40% Shield Coverage

15.8

51.8

See Chart Page 50

9

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

7

DBS CABLES BROADBAND CATV COAXIAL CABLES

RG 59, RG 6

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

75 83% 16.2 53.1

RG 59 20 AWG Solid .032" BCCS 40% AL Braid Shield Black PVC Jacket CATV 20 AWG .144 3.66 Bond-X AL .240 6.02 4-4590

CM 80oC (solid) .032" BCCS 44.5/M' 146.0/km FPE Foil + AL Braid 40% Shield Coverage 17.0/M' 55.8/km

RoHS

5 55 211 500 750 862 1000 1450 1800 2250

.8 1.4 3.4 5.2 6.5 7.0 7.7 9.3 10.3 11.9

2.5 6.0 11.0 17.1 21.4 22.9 25.2 30.5 33.8 39.0

RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket CATV 18 AWG .180 4.57 Bond-X AL .270 6.86 4-4061

CM (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km

75

83%

16.2

53.1

80oC

RoHS

5 55 211 500 750 862 1000 1450 1800 2250 3000

.5 1.4 2.6 4.1 5.1 5.5 6.0 7.9 8.4 10.1 11.0

1.6 4.6 8.5 13.5 16.7 18.0 19.7 25.9 27.6 33.1 36.1

RG 6 18 AWG Solid .040" BC 60% AL Braid Shield Black PVC Jacket CATV 18 AWG .180 4.57 Bond-X AL .270 6.86 4-4068

CM (solid) .040" BC 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 6.4/M' 21.0/km

75

83%

16.2

53.1

80oC

RoHS

5 55 211 500 750 862 1000 1450 1800 2250 3000

.5 1.4 2.6 4.1 5.1 5.5 6.0 7.9 8.4 10.1 11.0

1.6 4.6 8.5 13.5 16.7 18.0 19.7 25.9 27.6 33.1 36.1

RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket With .051" Glavanizied Steel Messenger 5 .5 18 AWG .180 4.57 Bond-X AL .270 6.86 75 83% 16.2 53.1 4-4061M CATV 55 1.4

CM 80oC (solid) .040" BCCS 28.0/M' 91.9/km FPE Foil + AL Braid 60% Shield Coverage 9.0/M' 29.5/km x .405 x 10.29

211 500 750 862 1000 1450 1800 2250 3000 2.6 4.1 5.1 5.5 6.0 7.9 8.4 10.1 11.0

RoHS

1.6 4.6 8.5 13.5 16.7 18.0 19.7 25.9 27.6 33.1 36.1

DUAL RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket With .047" Glavanizied Steel Messenger 5 .5 1.6 18 AWG .180 4.57 AL Braid .270 6.86 75 83% 16.2 53.1 4-4061DM CATV 55 1.4 4.6

CM (solid) .040" BCCS 28.0/M' 91.9/km FPE 60% Shield Coverage 9.0/M' 29.5/km x .703 x 17.86

211 500 750 862 1000 1450 1800 2250 3000 2.6 4.1 5.1 5.5 6.0 7.9 8.4 10.1 11.0 8.5 13.5 16.7 18.0 19.7 25.9 27.6 33.1 36.1

80 C

o

RoHS

DUAL RG 6 18 AWG Solid .040" BCCS 60% AL Braid Shield Black PVC Jacket 18 AWG .180 4.57 AL Braid .270 6.86 75 4-4061D CATV

CM (solid) .040" BCCS 28.0/M' 91.9/km FPE 60% Shield Coverage 9.0/M' 29.5/km x .550 x 13.97

83%

16.2

53.1

80oC

RoHS

5 55 211 500 750 862 1000 1450 1800 2250 3000

.5 1.4 2.6 4.1 5.1 5.5 6.0 7.9 8.4 10.1 11.0

1.6 4.6 8.5 13.5 16.7 18.0 19.7 25.9 27.6 33.1 36.1

8

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLESVIDEO COAXIAL CABLES 75 PRECISION

RG 59

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

RG 59/U 23 AWG Stranded (7x32) .023" BC 95% TC Braid Shield Black Polyethylene Jacket 8059PE

23 AWG (7x32) .023" BC 19.1/M' 62.6/km .146 SPE 3.71 TC Braid 95% Shield Coverage 4.5/M' 14.8/km .220 5.59 75 66% 21.0 68.9

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 .4 .6 1.2 3.3 4.7 6.8 8.0 9.9 11.6 11.9 13.8 1.1 2.0 3.9 10.8 15.4 22.3 26.2 32.5 38.0 39.0 45.3

80oC

RoHS

RG 59/U RISER 20 AWG Solid .032" BC 95% TC Braid Shield Black PVC Jacket CMR 20 AWG .145 3.68 AL Foil + .242 6.15 75 83% 2159R

SDI/HDTV Digital Video 75oC (solid) .032" BC 10.0/M' 32.8/km FPE TC Braid 95% Shield Coverage 3.8/M' 12.5/km

16.3

53.5

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.3 .6 .9 2.1 2.7 3.8 4.4 5.5 6.4 6.5 7.6 9.3 11.6 13.4

1.0 1.8 2.9 6.9 8.9 12.5 14.4 18.0 21.0 21.3 24.9 30.5 38.0 44.0

RG 59/U PLENUM 20 AWG Solid .032" BC 95% TC Braid Shield White Low Smoke PVC Jacket CMP 20 AWG .140 3.38 AL Foil + .199 5.05 75 84% 16.1 52.8 8-9159

SDI/HDTV Digital Video 75oC (solid) .032" BC 10.0/M' 32.8/km FFEP TC Braid 95% Shield Coverage 3.2/M' 10.5/km

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.3 .6 1.1 2.3 3.2 4.6 5.3 6.4 7.3 7.5 9.4 12.8 17.5 21.9

1.0 2.0 3.4 7.4 10.5 14.9 17.2 21.0 23.9 24.6 30.8 42.0 57.4 71.8

RG 59/U 22 AWG Stranded (7x29) .031" BC 95% TC Braid Shield Black PVC Jacket CM 22 AWG .145 3.68 AL Foil + .242 6.15 75 80% 2159F

High Flex SDI/HDTV Video Patch 75oC (7x29) .031" BC 12.2/M' 40.0/km FPE TC Braid 95% Shield Coverage 2.4/M' 7.8/km

17.0

55.7

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.2 .5 .9 2.5 3.5 5.1 6.0 7.4 8.7 8.9 10.5 13.3 16.9 20.3

.7 1.6 2.9 8.2 11.5 16.7 19.7 24.3 28.5 29.2 34.4 43.6 55.4 66.6

11

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

9

75 PRECISION VIDEO COAXIAL CABLES BROADBAND CATV COAXIAL CABLES

RG 59, 6

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

RG 59/U 75 Ohm Precision Video 20 AWG Solid .032" BC 2 x 98% TC Braid Shield Black Polyethylene Jacket 2062PE

20 AWG (solid) .032" BC 9.9/M' 32.5/km .198 SPE 5.03 2 x TC Braid 98% Shield Coverage 1.1/M' 3.6/km .305 7.75 75 66% 21.0 68.9

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 .3 .5 .8 2.1 3.0 4.3 5.1 6.3 7.4 7.6 9.2 .8 1.8 2.6 6.9 9.8 14.1 16.6 20.7 24.3 24.9 30.2

80oC

RoHS

RG 59/U 75 Ohm Precision Video RISER 20 AWG Solid .032" BC 2 x 95% TC Braid Shield Black PVC Jacket 2062R

Riser UL AWM Style 1354 30V 80oC CMR 20 AWG (solid) .032" BC 9.9/M' 32.5/km .198 FRPE 5.03 2 x TC Braid 95% Shield Coverage 1.1/M' 3.6/km .305 7.75 75 66% 21.0 68.9

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 .3 .5 .8 2.1 3.0 4.3 5.1 6.3 7.4 7.6 9.2 .8 1.8 2.6 6.9 9.8 14.1 16.6 20.7 24.3 24.9 30.2

RoHS

RG 59/U 75 Ohm Precision Video 20 AWG Stranded (7x29) .032" BC 2 x 95% TC Braid Shield Black PVC Jacket 1 .3 20 AWG .193 4.90 2 x TC Braid .305 7.75 75 66% 21.0 68.9 2262FX 3.6 .5

High Flex 60oC (7x29) .031" BC 12.2/M' 40.0/km FRPE 95% Shield Coverage 1.7/M' 5.6/km

10.0 71.5 135 270 360 540 720 750 1000 .9 2.5 3.6 5.1 6.0 7.4 8.7 8.9 10.5

RoHS

.9 1.7 2.9 8.0 11.6 16.7 19.7 24.3 28.5 29.2 34.4

RG 6 RISER 18 AWG Solid .040" BC 95% TC Braid Shield Black PVC Jacket CMR 18 AWG .180 4.57 AL Foil + .275 6.99 75 2106R

(solid) .040" BC 6.4/M' 21.0/km FPE TC Braid 95% Shield Coverage 2.8/M' 9.2/km

82%

16.2

53.1

75oC

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.2 .5 .7 1.6 2.1 3.0 3.4 4.3 4.9 5.0 5.9 7.3 9.1 10.7

.8 1.5 2.4 5.2 6.9 9.7 11.3 13.9 16.1 16.4 19.3 24.0 30.0 35.0

RG 6 PLENUM 18 AWG Solid .040" BC 95% TC Braid Shield White Low Smoke PVC Jacket CMP 18 AWG .170 4.32 AL Foil + .234 5.94 75 82% 16.2 8-9106

SDI/HDTV Digital Video 75oC (solid) .040" BC 6.4/M' 21.0/km FFEP TC Braid 95% Shield Coverage 2.8/M' 9.2/km

53.1

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.2 .5 .8 1.8 2.4 3.4 4.0 5.2 6.1 7.3 7.5 9.2 11.6 13.7

.8 1.5 2.5 5.8 7.9 11.2 13.1 17.1 20.0 23.9 24.6 30.2 38.0 44.9

10

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLESVIDEO COAXIAL CABLES 75 PRECISION

RG 11, RG 59 Sub-Mini

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

RG 11/U RISER 14 AWG Solid .064" BC 95% TC Braid Shield Black PVC Jacket 2111R

Riser SDI/HDTV Digital Video 75oC CMX 14 AWG (solid) .064" BC 2.5/M' 8.2/km .290 FPE 7.11 AL Foil + TC Braid 95% Shield Coverage 1.5/M' 4.9/km .405 10.3 75 85% 16.0 52.4

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000 .2 .3 .5 1.1 1.5 2.1 2.5 3.1 3.6 3.7 4.3 5.5 6.9 8.2 .5 1.0 1.5 3.6 4.8 6.9 8.0 1.0 11.7 12.0 14.1 18.0 22.6 26.9

RoHS

RG 11/U PLENUM 14 AWG Solid .064" BC 95% TC Braid Shield White PVDF Jacket CMP 14 AWG .274 6.96 AL Foil + .348 8.84 75 83% 7-9013

Plenum SDI/HDTV Digital Video 150oC (solid) .064" BC 2.5/M' 8.2/km FFEP TC Braid 95% Shield Coverage 1.6/M' 5.2/km

16.3

53.5

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.2 .3 .4 1.2 1.8 2.6 3.1 3.9 4.6 4.7 5.5 6.9 9.2 10.2

.5 .9 1.3 4.1 5.8 8.5 10.2 12.8 15.0 15.4 18.0 22.7 30.2 33.5

RG 59/U Sub-Mini RISER 25 AWG Stranded (19x37) .021" BC 95% TC Braid Shield Black PVC Jacket CMR 25 AWG .094 2.39 AL Foil + .150 3.81 75 82% 16.5 54.1 2459R

75oC (19x37) .021" BC 27.4/M' 89.9/km FPE TC Braid 95% Shield Coverage 5.4/M' 17.7/km

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.5 1.0 1.6 3.7 5.0 7.1 8.2 10.1 11.8 12.0 13.9 17.0 20.8 24.0

1.5 3.1 5.2 12.1 16.4 23.3 26.9 33.1 38.7 39.4 45.6 55.8 68.2 78.7

RG 59/U Sub-Mini RISER 23 AWG Solid .023" BC 95% TC Braid Shield Black PVC Jacket CMR 23 AWG .102 2.59 AL Foil + .159 4.03 75 83% 16.3 2359R

SDI/HDTV Digital Video 75oC (solid) .023" BC 20.1/M' 65.9/km FPE TC Braid 95% Shield Coverage 7.6/M' 24.9/km

53.5

RoHS

1 3.6 10.0 71.5 135 270 360 540 720 750 1000 1500 2250 3000

.4 .8 1.2 3.1 3.8 5.4 6.2 7.7 9.5 9.6 10.5 13.0 16.0 18.5

1.3 2.6 3.9 10.0 12.5 17.7 20.3 25.3 31.1 31.5 34.4 42.6 52.5 60.7

13

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

11

SECURITY CCTV CABLES BROADBAND CATV COAXIAL CABLES

RG 59 Mini, RG 59, RG 6, RG11

PART NO. UL/ ETL NEC TYPE COND. (STRAND) NOMINAL CORE OD & TYPE INCH mm SHIELD MTRL NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

RG 59 MINI 25 AWG Solid .018" BC 95% BC Braid Shield Black PVC Jacket 4-2559

75oC CM 25 AWG (solid) .018" BC .085 FPE 2.16 BC Braid 95% Shield Coverage .146 3.71 75 82% 16.2 53.1 See Chart Page 50

RoHS

RG 59 22 AWG Stranded (7x29) .031" BC 95% BC Braid Shield Black PVC Jacket CM 22 AWG .140 3.56 BC Braid .240 6.10 75 78% 4-8449S

75oC (7x29) .031" BC FPE 95% Shield Coverage

17.3

56.8

See Chart Page 50

RoHS

RG 59 20 AWG Solid .032" BC 95% BC Braid Shield Black PVC Jacket CM 20 AWG .145 3.68 BC Braid .240 6.10 4-4593A

75oC (solid) .032" BC FPE 95% Shield Coverage

75

82%

16.2

53.2

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BC 95% BC Braid Shield Black PVC Jacket CM 18 AWG .180 4.57 BC Braid .270 6.86 4-4006A

75oC (solid) .040" BC FPE 95% Shield Coverage

75

82%

16.2

53.1

See Chart Page 50

RoHS

RG 11 14 AWG Solid .064" BC 95% BC Braid Shield Black PVC Jacket CM 14 AWG .280 7.11 BC Braid .405 10.29 4-4011

75oC (solid) .064" BC FPE 95% Shield Coverage

75

82%

16.0

52.5

See Chart Page 50

RoHS

RG 6 18 AWG Solid .040" BC 60% AL Braid Shield Black UV Resistant PVC Jacket CM 18 AWG .180 4.57 Water Block .270 6.86 75 82% 4068WB

Water Block 75oC (solid) .040" BC FPE Foil + AL Braid 60% Shield Coverage

16.2

53.1

See Chart Page 50

RoHS

12

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES SECURITY CCTV CABLES

Surveillance & CCTV Plenum Rated RG 59 Mini, RG 59, RG 62, RG 6, RG 11

PART NO. UL/ ETL NEC TYPE COND. (STRAND) NOMINAL CORE OD & TYPE INCH mm SHIELD MTRL NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

RG 59 PLENUM MINI 25 AWG Solid .021" BC 95% BC Braid Shield White Low Smoke PVC Jacket 8-9459

75oC CMP 25 AWG (solid) .064" BC .078 FFEP 1.98 BC Braid 95% Shield Coverage .146 3.71 75 See Chart Page 50

RoHS

RG 62 PLENUM 22 AWG Solid .025" BCCS 95% BC Braid Shield White Low Smoke PVC Jacket CMP 22 AWG .146 3.71 BC Braid .204 5.18 75 8-9062

75oC (solid) .025" BCCS FFEP 95% Shield Coverage

See Chart Page 50

RoHS

RG 59 PLENUM 20 AWG Solid .032" BC 95% BC Braid Shield White Low Smoke PVC Jacket CMP 20 AWG .135 3.43 BC Braid .193 4.90 75 8-9593

75oC (solid) .032" BC FFEP 95% Shield Coverage

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 95% BC Braid Shield White Low Smoke PVC Jacket CMP 18 AWG .170 4.32 BC Braid .228 5.79 75 8-9006A

75oC (solid) .040" BC FFEP 95% Shield Coverage

See Chart Page 50

RoHS

RG 11 PLENUM 14 AWG Solid .064" BC 95% BC Braid Shield White PVDF Jacket CMP 14 AWG .274 6.96 BC Braid .348 8.84 75 7-9011

75oC (solid) .064" BC FFEP 95% Shield Coverage

See Chart Page 50

RoHS

15

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

13

SECURITY CCTV CABLES BROADBAND CATV COAXIAL CABLES

CATV & MATV Commercial or Schlage Systems

PART NO. UL/ ETL NEC TYPE COND. (STRAND) NOMINAL CORE OD & TYPE INCH mm SHIELD MTRL NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

75 83% 16.2 53.1 See Chart Page 50

RG 6 18 AWG Solid .040" BC 60% AL Braid Shield Black PVC Jacket CM 18 AWG .180 4.57 Bond-X AL .266 6.76 4-4068

75oC (solid) .040" BC FPE Foil + AL Braid 65% Shield Coverage

RoHS

RG 6 18 AWG Solid .040" BC 60% + 40% AL Braid Quad Shield Black PVC Jacket 18 AWG .180 4.57 Bond-X AL .298 7.57 75 83% 4-4068QS CM

75oC (solid) .040" BC FPE Foil + AL Braid 65% + 40% Shield Coverage

16.2

53.1

See Chart Page 50

RoHS

RG 6 SCHLAGE COAX 18 AWG Solid .040" BC 60% + 40% AL Braid Quad Shield Black PVC Jacket

4-4068QSL

Schlage Systems 75oC CM 18 AWG (solid) .040" BC .180 FPE 4.50 Bond-X AL Foil + AL Braid 65% + 40% Shield Coverage .298 7.57 75 83% 16.2 53.1 See Chart Page 50

RoHS

14

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES SECURITY CCTV CABLES

Commercial CATV & MATV Plenum Rated

PART NO. UL/ ETL NEC TYPE COND. (STRAND) NOMINAL CORE OD & TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

RG 59 PLENUM 20 AWG Solid .032" BC 80% AL Braid Shield White Low Smoke PVC Jacket CMP 20 AWG .135 3.43 AL Foil + .199 5.05 75 84% 15.8 8-9590

75oC (solid) .032" BC FFEP AL Braid 80% Shield Coverage

51.8

See Chart Page 50

RoHS

RG 59 PLENUM 20 AWG Solid .032" BCCS 60% + 40% AL Braid Shield White Low Smoke PVC Jacket 20 AWG .135 3.43 AL Foil + .223 5.66 75 84% 15.8 51.8 8-9470QS CMP

75oC (solid) .032" BCCS FFEP BC Braid 60% + 40% Shield Coverage

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 90% AL Braid Shield White Low Smoke PVC Jacket CMP 18 AWG .170 4.32 AL Foil + .233 5.92 75 84% 15.8 8-9070

75oC (solid) .040" BC FFEP AL Braid 90% Shield Coverage

51.8

See Chart Page 50

RoHS

RG 6 PLENUM 18 AWG Solid .040" BC 60% + 40% AL Braid Shield White Low Smoke PVC Jacket 18 AWG .170 4.32 AL Foil + .248 6.30 75 84% 15.8 51.8 8-9068QS CMP

75oC (solid) .040" BC FFEP BC Braid 60% + 40% Shield Coverage

See Chart Page 50

RG 11 PLENUM 14 AWG Solid .064" BC 60% AL Braid Shield White Low Smoke PVDF Jacket CMP 14 AWG .274 6.96 AL Foil + .348 8.84 75 84% 15.8 7-9012

75oC (solid) .064" BC FFEP AL Braid 60% Shield Coverage

51.8

See Chart Page 50

RoHS

17

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

15

BROADBAND CATV COAXIAL CABLES SECURITY CCTV CABLES

CCTV plus Audio or Camera Control CM/CMP Rated

PART NO. UL/ ETL NEC TYPE COND. (STRAND) NOMINAL CORE OD & TYPE INCH mm SHIELD MTRL NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

Siamese RG 59 20 AWG Solid .032" BC 95% BC Braid Shield + 18 AWG (7 Str.) BC 2 Conductor Black + White PVC CM 20 AWG .145 3.68 BC Braid .240 6.10 75 82% 16.2 56.8 See Chart 9912

75oC (solid) .032" BC FPE .066 PVC 1.68 95% Shield Coverage Unshld x .460 x 11.68 Page 50

RoHS

18 AWG (7 Str. BC) 2 Conductor

Siamese RG 59 20 AWG Solid .032" BC 95% CCA Braid Shield + 18 AWG (7 Str.) BC 2 Conductor Black + White PVC CM 20 AWG .145 3.68 CCA Braid .240 6.10 75 82% 16.2 56.8 See Chart 9912CA

75oC (solid) .032" BC FPE .066 PVC 1.68 95% Shield Coverage Unshld x .460 x 11.68 Page 50

RoHS

18 AWG (7 Str. BC) 2 Conductor

Siamese RG 6 18 AWG Solid .040" BC 95% BC Braid Shield + 18 AWG (7 Str.) BC 2 Conductor Black + White PVC CM 18 AWG .180 4.57 BC Braid .266 6.76 75 82% 16.2 53.1 See Chart 9906

75oC (solid) .040" BC FPE .066 PVC 1.68 95% Shield Coverage Unshld x .460 x 11.68 Page 50

RoHS

18 AWG (7 Str. BC) 2 Conductor

Siamese RG 59 PLENUM 20 AWG Solid .032" BC 95% BC BS + 18 AWG (7 Str.) BC 2 Cond. Blk + Wht. LS PVC CMP 20 AWG .140 3.56 BC Braid .199 5.05 75 84% 15.8 51.8 See Chart 8-9992

Plenum 75oC (solid) .032" BC FFEP .059 PVC 1.50 95% Shield Coverage Unshld x .383 x 9.72 Page 50

RoHS

18 AWG (7 Str. BC) 2 Conductor

Siamese RG 6 PLENUM 18 AWG Solid .040" BC 95% BC BS + 18 AWG (7 Str.) BC 2 Cond. Blk + Wht LS PVC CMP 18 AWG .170 4.32 BC Braid .232 5.89 75 84% 15.8 51.8 See Chart 8-9996

75oC (solid) .040" BC FFEP .059 PVC 1.50 95% Shield Coverage Unshld x .416 x 10.57 Page 50

RoHS

18 AWG (7 Str. BC) 2 Conductor

Siamese RG 59 22 AWG Stranded (7x30) .030" BC 95% BC BS + 22 AWG (7 Str.) TC 2 Cond. Shld Blk PVC CL2 22 AWG .146 3.71 BC Braid .242 6.15 75 78% 17.3 56.8 See Chart 9900

75oC (7x30) .030" BC FPE .054 PVC 1.37 95% Shield Coverage x .470 x 11.94 Page 50

RoHS

22 AWG (7 Str. TC) 2 Conductor

AL Foil Shld

16

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES

RG 174/U, RG 58/U, RG 8

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH

50 RF

NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

RG 174/U 26 AWG Stranded (7x34) .019" BCCS 90% TC Braid Shield Black PVC Jacket AWM 26 AWG .060 1.52 TC Braid .110 2.79 50 66% 8174

1354 UL AWM Style 1354 30 V 60oC (7x34) .019" BCCS 97/M' 318.2/km SPE 90% Shield Coverage 10.7/M' 35.1/km

30.8

101.0

RoHS

1 10 50 100 200 400 700 900 1000

1.9 3.3 5.8 8.4 12.5 19.0 27.0 31.0 34.0

6.2 10.8 19.0 27.6 41.0 62.3 88.6 101.7 111.5

RG 58/U 20 AWG Solid .032" BC 80% BC Braid Shield Black PVC Jacket AWM 20 AWG .116 2.95 BC Braid .195 4.95 8158

UL AWM Style 1354 75oC 1354 (Solid) .032" BC 10.0/M' 33.1/km SPE 80% Shield Coverage 5.5/M' 18.0/km

51.5

66%

28.5

93.5

RoHS

1 10 50 100 200 400 700 900 1000

.3 1.1 2.5 3.8 5.6 8.4 11.7 13.7 14.5

1.1 3.6 8.2 12.5 18.4 27.6 38.4 44.9 47.6

RG 58A/U 20 AWG Stranded (19x33) .035" TC 95% TC Braid Shield Black PVC Jacket CM 20 AWG .116 2.95 TC Braid .195 4.95 50 66% 4-8058A

75oC (19x33) .035" TC 10.8/M' 35.4/km SPE 95% Shield Coverage 4.1/M' 13.4/km

30.8

101.0

RoHS

1 10 50 100 200 400 700 900 1000

.4 1.5 3.7 5.4 8.1 12.4 17.7 21.1 22.8

1.4 4.9 12.1 17.7 26.6 40.7 58.1 69.2 74.8

RG 58/U 20 AWG Solid .032" BC 95% TC Braid Shield Black PVC Jacket CM 20 AWG .116 2.95 TC Braid .195 4.95 4-8058

UL AWM Style 1354 30 V 80oC (Solid) .032" BC 10.2/M' 33.5/km SPE 95% Shield Coverage 4.1/M' 13.4/km

51.5

66%

28.5

93.5

RoHS

1 10 50 100 200 400 700 900 1000

.3 1.1 2.5 3.8 5.6 8.4 11.7 13.7 14.5

1.1 3.6 8.2 12.5 18.4 27.6 38.4 44.9 47.6

RG 8X 16 AWG Stranded (19x29) .058" BC 95% BC Braid Shield Black PVC Jacket CM 16 AWG .155 3.94 BC Braid .242 6.15 50 82% 4-8282X

UL AWM Style 1354 30 V 80oC (19x29) .058" BC 4.3/M' 14.1/km FPE 95% Shield Coverage 3.3/M' 10.8/km

24.8

81.4

RoHS

1 10 50 100 200 400 700 900 1000

.3 .9 2.1 3.1 4.5 6.6 9.1 10.7 11.2

.8 2.9 6.9 10.2 14.8 21.7 29.9 35.1 36.7

RG 8/U 13 AWG Stranded (7x21) .085" BC 97% BC Braid Shield Black PVC Jacket CL2 13 AWG .285 7.24 BC Braid .405 10.29 52 66% 8208

75oC (7x21) .085" BC 1.9/M' 6.2/km SPE 97% Shield Coverage 1.2/M' 3.9/km

28.5

93.5

RoHS

1 10 50 100 200 400 700 900 1000

.2 .6 1.3 1.9 2.8 4.2 5.9 6.9 7.4

.5 1.8 4.3 6.2 9.2 13.8 19.4 22.6 24.3

RG 8/U 13 AWG Stranded (7x21) .085" BC 97% BC Braid Shield Black Non-Contaminating PVC Jacket CL2X 13 AWG .285 7.24 BC Braid .405 10.29 52 66% 28.5 93.5 8208A

UL AWM Style 1354 30 V 60oC (7x21) .085" BC 1.9/M' 6.2/km SPE 97% Shield Coverage 1.2/M' 3.9/km

RoHS

1 10 50 100 200 400 700 900 1000

.2 .6 1.3 1.9 2.8 4.2 5.9 6.9 7.4

.5 1.8 4.3 6.2 9.2 13.8 19.4 22.6 24.3

19

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

17

LOW LOSS 50 RF BROADBAND CATV COAXIAL CABLES

RG 8, RG 58

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

RG 58 19 AWG Solid .037" BC 96% TC Braid Shield Black Polyethylene Jacket 19 AWG .110 2.79 Bond-X AL .195 4.95 50 LL195

80oC (solid) .037" BC 7.6/M' 24.9/km FPE Foil + TC Braid 96% Shield Coverage 4.2/M' 13.8/km

77%

24.3

79.7

RoHS

30 50 150 220 450 900 1500 1800 2000 2500 3000

2.0 2.5 4.0 4.9 7.1 10.3 13.7 15.2 16.1 18.3 20.5

6.6 8.2 13.3 16.1 23.4 33.8 44.8 49.7 52.8 60.1 67.3

RG 58 19 AWG Solid .037" BC 96% TC Braid Shield Black PVC Jacket CMR 19 AWG .110 2.79 Bond-X AL .195 4.95 LR195

80oC (solid) .037" BC 7.6/M' 24.9/km FPE Foil + TC Braid 96% Shield Coverage 4.2/M' 13.8/km

50

77%

24.3

79.7

RoHS

30 50 150 220 450 900 1500 1800 2000 2500 3000

2.0 2.5 4.0 4.9 7.1 10.3 13.7 15.2 16.1 18.3 20.5

6.6 8.2 13.3 16.1 23.4 33.8 44.8 49.7 52.8 60.1 67.3

RG 8/U 10 AWG Stranded (19 x .021) .108" BC 96% TC Braid Shield Black PVC Jacket 10 AWG .286 7.26 Bond-X AL .405 10.29 50 84% 1418

75oC (19 x .021) .108" BC .9/M' 3.0/km SPE Foil + TC Braid 96% Shield Coverage 1.8/M' 5.9/km

24.6

80.7

RoHS

1 10 50 100 200 400 700 900 1000

.3 .5 1.1 1.6 2.2 3.1 4.1 4.6 4.8

1.0 1.6 3.6 5.1 7.2 10.1 10.3 15.1 15.9

RG 8/U 10 AWG Stranded (19 x .021) .108" BC 96% TC Braid Shield High Flex Matte Black PVC Jacket 10 AWG .286 7.24 Bond-X AL .405 10.29 50 83% 24.6 80.7 1408

High Flex 80oC (19x.021) .108" BC 1.1/M' 3.7/km FPE Foil + TC Braid 96% Shield Coverage 1.1/M' 3.6/km

RoHS

1 10 50 100 200 400 700 900 1000

.4 .6 1.3 1.8 2.5 3.5 4.6 5.1 5.4

1.3 2.1 4.4 6.0 8.4 11.5 15.0 16.9 17.7

RG 8X 15 AWG Solid .057" BC 95% TC Braid Shield Black Polyethylene Jacket 15 AWG .150 3.81 Bond-X AL .240 6.10 50 LL240

80oC (solid) .057" BC 3.2/M' 10.5/km FPE Foil + TC Braid 95% Shield Coverage 3.5/M' 11.5/km

86%

23.0

75.5

RoHS

30 50 150 220 450 900 1500 1800 2000 2500 3000

1.3 1.6 2.8 3.4 4.9 7.0 9.1 10.1 10.7 12.0 13.4

4.1 5.3 9.3 11.1 16.1 22.9 30.0 33.2 35.0 39.5 43.9

18

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES

RG 8

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH

LOW LOSS 50 RF

NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

50 86% 23.0 75.5

30 50 150 220 450 900 1500 1800 2000 2500 3000 1.3 1.6 2.8 3.4 4.9 7.0 9.1 10.1 10.7 12.0 13.4 4.1 5.3 9.3 11.1 16.1 22.9 30.0 33.2 35.0 39.5 43.9

RG 8X 15 AWG Solid .057" BC 96% TC Braid Shield Black PVC Jacket CMR 15 AWG .150 3.81 Bond-X AL .240 6.10 2400PE

80oC (solid) .057" BC 3.2/M' 10.5/km FPE Foil + TC Braid 96% Shield Coverage 3.5/M' 11.5/km

RoHS

RG 8 10 AWG Solid .108" BCCA 96% TC Braid Shield Black Polyethylene Jacket 10 AWG .285 7.24 Bond-X AL .405 10.29 50 86% 4000PE

80oC (solid) .108" BCCA 1.3/M' 4.4/km FPE Foil + TC Braid 96% Shield Coverage 1.8/M' 5.8/km

23.0

75.5

RoHS

30 50 150 220 450 900 1500 1800 2000 2500 3000

.7 .9 1.5 1.8 2.7 3.8 5.1 5.6 6.0 6.7 7.5

2.1 2.8 4.9 6.0 8.8 12.6 16.6 18.5 19.6 22.0 24.4

RG 8 10 AWG Solid .108" BCCA 96% TC Braid Shield Black Flexible Matte PVC Jacket 10 AWG .285 7.24 Bond-X AL .405 10.29 50 86% 4000

80oC (solid) .108" BCCA 1.3/M' 4.4/km FPE Foil + TC Braid 96% Shield Coverage 1.8/M' 5.8/km

24.8

81.4

RoHS

30 50 150 220 450 900 1500 1800 2000 2500 3000

.7 .9 1.5 1.8 2.7 3.8 5.1 5.6 6.0 6.7 7.5

2.1 2.8 4.9 6.0 8.8 12.6 16.6 18.5 19.6 22.0 24.4

21

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

19

BROADBAND CATV COAXIAL CABLES 50 RF MIL TYPE

RG 8A/U, RG 59C/U, RG 174/U, RG 213, RG 214, RG 223

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

93.5

1 10 50 100 200 400 700 900 1000 4000 .2 .6 1.3 1.9 2.8 4.2 5.9 6.9 7.4 23.2 .5 1.8 4.3 6.2 9.2 13.8 19.4 22.6 24.3 76.1

MIL TYPE RG 8/U 13 AWG Stranded (7x21) .089" BC 97% BC Braid Shield Black NCV Jacket CMX 13 AWG .285 7.24 BC Braid .405 10.29 52 66% 28.5 8208A

UL AWM Style 1354 30 V 60oC (7x21) .089" BC 1.9/M' 6.2/km SPE 97% Shield Coverage 1.2/M' 3.9/km

RoHS

MIL TYPE RG 58C/U 20 AWG Stranded (19x33) .035" TC 95% TC Braid Shield Black NCV Jacket CMX 20 AWG .115 2.92 TC Braid .195 4.90 50 66% 30.8 101.0 8058C

85oC (19x33) .035" TC 10.8/M' 35.4/km SPE 95% Shield Coverage 4.1/M' 13.4/km

RoHS

1 10 50 100 200 400 700 900 1000

.4 1.4 3.3 4.9 7.3 11.5 17.0 20.0 21.5

1.4 4.6 10.8 16.1 24.0 37.7 55.8 65.6 70.5

MIL TYPE RG 174/U 26 AWG Stranded (7x34) .019" BCCS 90% TC Braid Shield Black NCV Jacket AWM 26 AWG .060 1.52 TC Braid .110 2.79 50 66% 30.8 101.0 8174A

1354 UL AWM Style 1354 30 V 60oC (7x34) .019" BCCS 97.0/M' 318.2/km SPE 90% Shield Coverage 10.7/M' 35.1/km

RoHS

1 10 50 100 200 400 700 900 1000

1.9 3.3 5.8 8.4 12.5 19.0 27.0 31.0 34.0

6.2 10.8 19.0 27.6 41.0 62.3 88.6 101.7 111.5

MIL TYPE RG 213 13 AWG Stranded (7x21) .089" BC 97% BC Braid Shield Black NCV Jacket CMX 13 AWG .285 7.24 BC Braid .405 10.29 50 66% 30.8 8213A

UL AWM Style 1354 30 V 80oC (7x21) .089" BC 1.7/M' 5.6/km SPE 97% Shield Coverage 1.2/M' 3.9/km

101.0

RoHS

1 10 50 100 200 400 700 900 1000 4000

.2 .6 1.3 1.9 2.7 4.1 6.5 7.6 8.0 21.5

.6 1.8 4.3 6.2 8.9 13.5 21.3 24.9 26.2 70.5

MIL TYPE RG 214 13 AWG Stranded (7x21) .089" Silver Coated Copper 97% 2 x SCC Braid Shield Black NCV Jacket 1 .2 .6 CMX 13 AWG .285 7.24 2 x SCC Braid .425 10.80 50 66% 30.8 101.0 8214SC 10 .6 1.8

UL AWM Style 1354 30 V 80oC (7x21) .089" SCC 1.7/M' 5.6/km SPE 97% Shield Coverage .7/M' 2.3/km

50 100 200 400 700 900 1000 4000 1.3 1.9 2.7 4.1 6.5 7.6 8.0 20.0

RoHS

4.3 6.2 8.9 13.4 21.3 24.9 26.2 65.6

MIL TYPE RG 223 19 AWG Solid .036" Silver Coated Copper 95% 2 x SCC Braid Shield Black NCV Jacket 1 CMX 19 AWG .117 2.95 2 x SCC Braid .212 5.38 50 66% 30.8 101.0 8223SC 10

75oC (solid) .036" SCC 8.8/M' 28.9/km SPE 95% Shield Coverage 2.5/M' 8.2/km

50 100 200 400 700 900 1000

RoHS

.4 1.2 2.8 4.1 6.0 8.8 12.0 13.8 14.5

1.1 3.9 8.2 13.5 19.7 28.9 39.4 45.3 47.6

20

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES & TWINAXIAL CABLES NETWORK COAXIAL

RG 62A/U

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

93 Ohm RG 62B/U 24 AWG Stranded (7x32) .024" BCCS 95% BC Braid Shield Black Non-Contaminating PVC Jacket 1 .3 1.0 CMX 24 AWG .146 3.71 BC Braid .242 6.15 93 84% 13.5 44.3 8162B 10 .9 3.0

UL AWM Style 1354 30 V 60oC (7x32) .024" BCCS 59.0/M' 193.6/km SPE 95% Shield Coverage 2.9/M' 9.5/km

50 100 200 400 700 900 1000 2.0 2.9 4.2 6.1 8.6 10.1 11.0

RoHS

6.6 9.5 13.8 20.0 28.2 33.1 36.1

93 Ohm RG 62/U 22 AWG Solid .025" BCCS 95% BC Braid Shield Black PVC Jacket CL2 22 AWG .146 3.71 BC Braid .242 6.15 93 84% 8062A

75oC (Solid) .025" BCCS 41.2/M' 135.1/km SPE 95% Shield Coverage 2.9/M' 9.5/km

13.5

44.3

RoHS

1 10 50 100 200 400 700 900 1000

.3 .9 1.9 2.7 3.8 5.3 7.3 8.2 8.7

.8 2.8 6.2 8.9 12.5 17.4 23.9 26.9 28.5

93 Ohm RG 62A/U 22 AWG Solid .025" BCCS 95% BC Braid Shield Black PVC Jacket CM 22 AWG .146 3.71 BC Braid .242 6.15 93 84% 4-8062A

CL2 UL AWM Style 1478 30 V 60oC (Solid) .025" BCCS 41.2/M' 135.1/km SPE 95% Shield Coverage 2.9/M' 9.5/km

13.5

44.3

RoHS

1 10 50 100 200 400 700 900 1000

.3 .9 1.9 2.7 3.8 5.3 7.3 8.2 8.7

.8 2.8 6.2 8.9 12.5 17.4 23.9 26.9 28.5

PLENUM 93 Ohm RG 62/U 22 AWG Solid .025" BCCS 95% BC Braid Shield White Low Smoke PVC Jacket 1 NEC: 22 AWG .146 3.71 BC Braid .204 5.18 93 85% 15.8 41.0 8-9262 10

CMP 75oC (Solid) .025" BCCS 41.2/M' 135.2/km FFEP 95% Shield Coverage 3.4/M' 11.2/km

50 100 200 400 700 900 1000

RoHS

.3 .9 1.9 2.7 3.8 5.3 7.3 8.2 8.7

1.8 3.0 6.2 8.9 12.5 17.4 23.9 26.9 28.5

93 Ohm RG 62A/U 22 AWG Solid .025" BCCS 80% BC Braid Shield Black PVC Jacket 1354 22 AWG .146 3.71 BC Braid .242 6.15 93 84% 8265A

AWM (Solid) .025" BCCS 41.2/M' 135.1/km SPE 80% Shield Coverage 2.9/M' 9.5/km

13.5

44.3

RoHS

1 10 50 100 200 400 700 900 1000

.3 .9 1.9 2.7 3.8 5.3 7.3 8.2 8.7

.8 2.8 6.2 8.9 12.5 17.4 23.9 26.9 28.5

23

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

21

DATA & COMPUTER NETWORK CABLES BROADBAND CATV COAXIAL CABLES

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

78% 17.3 56.8

30 AWG Stranded (7x38) .012" TC 89% TC Braid Shield Black PVC Jacket AWM 30 AWG .058 1.47 TC Braid .097 2.46 75 2230

1354 UL AWM Style 1375 30 V 60oC (7x38) .012" TC 100.0/M' 328.0/km

HDFPE

89% Shield Coverage 11.7/M' 38.4/km

RoHS

1 10 50 100 200 400 700 900 1000

.7 1.3 1.6 2.2 5.1 7.3 10.5 15.5 26.6

2.3 4.3 5.2 7.2 16.7 23.9 34.4 50.9 87.3

Section 3B

27 AWG Stranded (7x35) .017" BCCS 93% TC Braid Shield Black PVC Jacket AWM 27 AWG .100 2.54 TC Braid .150 3.81 75 2221

1354 UL AWM Style 1354 30 V 60oC (7x35) .017" BCCS 120.0/M' 393.7/km SPE 93% Shield Coverage 5.7/M' 18.7/km

66%

20.5

67.3

RoHS

1 10 50 100 200 400 700 900 1000

1.2 2.4 4.2 5.7 8.3 12.1 16.5 19.0 20.0

3.9 7.9 13.8 18.7 27.2 39.7 54.1 62.3 65.6

RG 11/U 18 AWG Stranded (7x26) .048" TC 97% BC Braid Shield Black NCV Jacket AWM 18 AWG .285 7.24 BC Braid .405 10.29 75 66% 8211A

1354 VW-1 60oC (7x26) .048" TC 6.1/M' 20.0/km SPE 97% Shield Coverage 1.2/M' 3.9/km

20.5

67.2

RoHS

1 10 50 100 200 400 700 900 1000

.2 .7 1.3 2.0 2.9 4.2 5.8 6.8 7.1

.6 2.2 4.3 6.6 9.5 13.8 19.0 22.3 23.3

RG 11/U 18 AWG Stranded (7x26) .048" Flame Retardant PE TC 97% BC Braid Shield Black PVC Jacket 1 CMX 18 AWG .285 7.24 BC Braid .405 10.29 75 66% 20.5 67.2 4-8211 10

60oC (7x26) .048" TC 6.1/M' 20.0/km FRPE 97% Shield Coverage 1.2/M' 3.9/km

RoHS

50 100 200 400 700 900 1000

.2 .7 1.3 2.0 2.9 4.2 5.8 6.8 7.1

.6 2.2 4.3 6.6 9.5 13.8 19.0 22.3 23.3

18 AWG Stranded (7x26) .048" TC 2 BC Braid Shield (95% Shield Coverage) Black NCV PVC Jacket CMH 18 AWG .285 7.24 2 BC Braid .425 10.80 75 66% 20.5 67.2 8216A

VW-1 60oC (7x26) .048" TC 6.1/M' 20.0/km SPE 95% Shield Coverage .8/M' 2.6/km

RoHS

1 10 50 100 200 400 700 900 1000

.2 .7 1.3 2.0 2.9 4.2 5.8 6.8 7.1

.6 2.2 4.3 6.6 9.5 13.8 19.0 22.3 23.3

22

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES INDUSTRIAL TWINAXIAL DATA CABLES

Blue Jacket Cables

Blue Jacket cable provides factory floor interface to Power Limited Controls and control network devices. Often referred to as Blue Hose®, ADC's Blue Jacket is designed to be used in light industrial environments and comes in a Direct Burial and High Flex version.

PART NO.

UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm

SHIELD MTRL NOM DCR

NOMINAL OD INCH

NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m mm

78 66% 19.7 64.6

1 10 50 100 200 400 .6 2.1 3.6 7.5 11.0 16.0 2.0 6.9 11.8 24.6 36.1 52.5

78 Ohm 20 AWG Stranded (7x28) .037" TC - Foil + 55% TC Braid Shield (100% Shield Coverage) Blue SLR PVC Jacket 4-2214BE

UL AWM Style 2464 300 V 80oC

Allen Bradley P/N: 1770-CD Belden Equal 9463

CM CL2

20 AWG (7x28) .037" TC 9.5/M' 31.0/km (Color Code:Clear, Blue)

.154 SPE

3.91

Foil + 55% TC Braid 4.1/M' 13.4/km

.238

6.05

78 Ohm 20 AWG Stranded (7x28) .037" TC - Foil + 55% TC Braid Shield (100% Shield Coverage) Blue SLR LDPE Jacket 1 .6 2.0 20 AWG .154 3.91 Foil + .238 6.05 78 66% 19.7 64.6 2214DB 10 2.1 6.9

Flooded Direct Burial 300 V 80oC

Allen Bradley P/N: 1770-CD Belden Equal 9463DB

(7x28) .037" TC 9.5/M' 31.0/km (Color Code:Clear, Blue)

SPE

55% TC Braid 4.1/M' 13.4/km

50 100 200 400

3.6 7.5 11.0 16.0

11.8 24.6 36.1 52.5

78 Ohm 20 AWG Stranded (42x36) .037" TC - Foil + 85% TC Braid Shield (100% Shield Coverage) Blue SLR PVC Jacket 1 .6 2.0 20 AWG .154 3.91 Foil + .243 6.17 78 66% 19.7 64.6 4-2224FX CM 10 2.1 6.9

CL2 High Flex UL AWM Style 2464 300 V 80oC

Allen Bradley P/N: 1770-CD Belden Equal 9463F

(41x36) .037" TC 9.5/M' 31.0/km (Color Code:Clear, Blue)

SPE

85% TC Braid 5.0/M' 6.4/km

50 100 200 400

3.6 7.5 11.0 16.0

11.8 24.6 36.1 52.5

78 Ohm 20 AWG Stranded (7x28) .037" TC - Foil + 85% TC Braid Shield (100% Shield Coverage) Blue SLR PVC Jacket 1 .6 2.0 CM 20 AWG .077 1.95 Foil + .244 6.19 78 66% 19.7 64.6 2224DB 10 2.1 6.9

CL2 Flooded Direct Burial

Allen Bradley P/N 9022B

(7x28) .037" TC 9.5/M' 31.0/km (Color Code:Clear, Blue)

SPE

57% TC Braid

50 100 200 400

3.6 7.5 11.0 16.0

11.8 24.6 36.1 52.5

25

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

23

BROADBAND CATV COAXIAL CABLES

FIRE ALARM CABLES - FPLR 25 FIRE ALARM CABLES - FPLP26 FIRE ALARM CABLES - FPLR DATA GRADE 27 FIRE ALARM CABLES - FPLP DATA GRADE 28 FIRE ALARM - NPLF 29 FIRE ALARM CABLES - NYC LOCAL LAW 530

FIRE ALARM CABLES - FPLR

Commercial Applications Power Limited Product Description FPLR/CMG FT4 Rated Conductor Bare copper Unshielded & Shielded Insulation conductors, PVC

Specifications Bare Copper .010" (25mm) PVC PVC insulation, Conductors Jacket cabled, Red PVC Shield Aluminum Foil jacket with rip cord. NEC Articles 760 FPLR Sequential footage Voltage Rating 300 V marking. Temp. Rating 75oC

Shielded version has an aluminum tape and drain shielding.

Applications Cond · Fire Protection 1 · Alarm 2 · Signal 3 · Monitor/Detection 4 · Audio Circuits 5 · Control Circuits 6 · Initiating Circuits 7 · Notification 8 Circuits 9 10

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

Color Code Chart Color Cond Color Black 11 Red/Green Red 12 Red/Blue Brown Blue Orange Yellow Purple Green Red/Black Red/White

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

UNSHIELDED FPLR 300 V 75oC

81802 81804 81806 81808 81810 81812 81602 81604 81402 81404 81202 18/2 18/4 18/6 18/8 18/10 18/12 16/2 16/4 14/2 14/4 12/2 SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .381 .381 .381 .381 .381 .381 .381 .381 .381 .381 .381 .151 .176 .212 .230 .272 .281 .174 .201 .213 .251 .244 3.84 4.47 5.38 5.84 6.91 7.14 4.42 5.11 5.41 6.38 6.20 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 17 30 45 61 71 83 25 45 38 70 59

SHIELDED FPLR 300 V 75oC

81802SD 81804SD 81602SD 81604SD 81402SD 81404SD 81202SD 18/2 18/4 16/2 16/4 14/2 14/4 12/2 SOL SOL SOL SOL SOL SOL SOL .015 .015 .015 .015 .015 .015 .015 .381 .381 .381 .381 .381 .381 .381 .155 .180 .178 .205 .217 .255 .251 3.94 4.57 4.52 5.21 5.51 6.48 6.38 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 21 36 29 52 43 79 64

27

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 Fax: (828)389 3922 · www.adcable.com Phone: (800) 343 2579 · · www.adcable.com

27

25

FIRE ALARM CABLE - FPLP

Commercial Applications Power Limited Product Description FPLP Rated Conductor BC conductors, Unshielded & Shielded Insulation Low smoke

PVC insulation, Conductors cabled, Red low smoke PVC jacket with rip cord. Sequential ft. marking.

Shielded version has an aluminum tape and drain shielding.

Specifications Bare Copper

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

18-16 AWG .010" (25mm)LSPVC 14-12 AWG .011" (28mm)LSPVC Jacket Low Smoke PVC Shield Aluminum Foil NEC Articles 760 FPLP Voltage Rating 300 V Temp. Rating 75oC

Applications Color Code Chart Cond Color · Fire Protection 1 Black · Alarm 2 Red · Signal 3 Brown · Monitor/Detection 4 Blue · Audio Circuits 5 Orange · Control Circuits 6 Yellow · Initiating Circuits 7 Purple · Notification 8 Green Circuits 9 Red/Black 10 Red/White

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

UNSHIELDED FPLP 300 V 75oC

981802 981804 981806 981808 981810 981602 981604 981402 981404 981202 18/2 18/4 18/6 18/8 18/10 16/2 16/4 14/2 14/4 12/2 SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .381 .381 .381 .381 .381 .381 .381 .381 .381 .381 .151 .176 .212 .230 .272 .172 .201 .205 .247 .239 3.84 4.47 5.38 5.84 6.91 4.37 5.11 5.21 6.27 6.07 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 18 31 46 63 73 26 47 38 74 59

SHIELDED FPLP 300 V 75oC

981802SD 981804SD 981602SD 981604SD 981402SD 981404SD 981202SD 18/2 18/4 16/2 16/4 14/2 14/4 12/2 SOL SOL SOL SOL SOL SOL SOL .015 .015 .015 .015 .015 .015 .015 .381 .381 .381 .381 .381 .381 .381 .158 .184 .176 .205 .212 .248 .246 4.01 3.05 4.47 5.21 5.38 6.30 6.25 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 22 36 31 58 45 81 65

26

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

FIRE ALARM CABLE - FPL DATA GRADE

Data Grade Addressable Systems Product Description FPL Rated Bare copper Unshielded & Shielded conductors, PP

Specifications Bare Copper 18 AWG .015" PP 16 AWG .015" PP insulation, Conductors cabled, Red PVC 14 AWG .020" PP jacket with rip cord. 12 AWG .020" PP Sequential footage Jacket PVC marking. Shield Aluminum Foil Shielded version has an NEC Articles 760 FPL aluminum tape and drain Voltage Rating 300 V shielding. Temp. Rating 75oC Conductor Insulation Applications Color Code Chart Cond Color · Fire Protection 1 Black · Alarm 2 Red · Signal · Monitor/Detection · Audio Circuits · Control Circuits · Initiating Circuits · Notification Circuits

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP CAP pF/FT WT / 1M'

UNSHIELDED FPL 300 V 75oC

831802 831602 831402 831202 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .030 .030 .030 .030 .760 .760 .760 .760 .182 .223 .240 .282 4.62 5.66 6.10 7.16 500'/1000' 500'/1000' 500'/1000' 500'/1000' 15 17 18 19 19 26 37 63

SHIELDED FPL 300 V 75oC

831802SD 831602SD 831402SD 831202SD 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .030 .030 .030 .030 .760 .760 .760 .760 .210 .226 .262 .292 5.33 5.74 6.65 7.42 500'/1000' 500'/1000' 500'/1000' 500'/1000' 23 27 31 35 20 27 38 64

* Please check with your factory representative for order minimum and current manufacturing lead time.

29

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

27

FIRE ALARM CABLE - FPLP DATA GRADE

Data Grade Addressable Systems Product Description FPLP Rated BC conductors, Unshielded & Shielded Low smoke PVC

insulation, Cond. cabled, Red low smoke PVC jacket with rip cord. Sequential ft. marking. Specifications Conductor Bare Copper Insulation 18 AWG .014" Halar 16 AWG .016" Halar 14 AWG .018" Halar 12 AWG .020" Halar Jacket Low Smoke PVC Shield Aluminum Foil NEC Articles 760 FPLP Voltage Rating 300 V Temp. Rating 75oC Applications Color Code Chart Cond Color · Fire Protection 1 Black · Alarm 2 Red · Signal · Monitor/Detection · Audio Circuits · Control Circuits · Initiating Circuits · Notification Circuits

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

Shielded version has an aluminum tape and drain shielding.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

CAP pF/FT

SHIP WT / 1M'

UNSHIELDED FPLP 300 V 75oC

987802 987602 987402 987202 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .015 .015 .020 .020 .381 .381 .508 .508 .172 .196 .242 .282 4.37 4.98 6.15 7.16 500'/1000' 500'/1000' 500'/1000' 500'/1000' 21 23 23 25 17 25 37 60

SHIELDED FPLP 300 V 75oC

987802SD 987602SD 987402SD 987202SD 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .015 .015 .020 .020 .381 .381 .508 .508 .172 .203 .247 .289 4.37 5.16 6.27 7.34 500'/1000' 500'/1000' 500'/1000' 500'/1000' 28 32 36 41 19 26 38 58

* Please check with your factory representative for order minimum and current manufacturing lead time.

28

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

FIRE ALARM - NPLF

Commercial Applications Non Power Limited Product Description NPLF Rated BC conductors, PVC/ Conductor Unshielded & Shielded Nylon insulation, Insulation

Cond.cabled, PVC jacket with rip cord. Sequential ft. marking. Specifications Bare Copper .016" PVC .005" Nylon Jacket PVC Shield Aluminum Foil NEC Articles 760 NPLF Voltage Rating 150 V Temp. Rating 105oC Applications Color Code Chart Cond Color · Fire Protection 1 Black · Alarm 2 Red · Signal · Monitor/Detection · Audio Circuits · Control Circuits · Initiating Circuits · Notification Circuits

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

Shielded version has an aluminum tape and drain shielding.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

UNSHIELDED NPLF 150 V 105oC

86802 86602 86402 86202 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .037 .037 .042 .042 .940 .940 1.07 1.07 .232 .252 .299 .328 5.89 6.40 7.59 8.33 500'/1000' 500'/1000' 500'/1000' 500'/1000' 33 42 60 81

SHIELDED NPLF 150 V 105oC

86802SD 86602SD 86402SD 86202SD 18/2 16/2 14/2 12/2 SOL SOL SOL SOL .037 .037 .042 .042 .940 .940 1.07 1.07 .244 .264 .284 .328 6.20 6.17 7.21 8.33 500'/1000' 500'/1000' 500'/1000' 500'/1000' 36 47 66 90

31

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

29

FIRE ALARM CABLES - NYC LOCAL LAW 5

Commercial Applications Unshielded & Shielded

Product Description BC conductors, Low smoke PVC insulation, Cond. cabled, Red low smoke Plenum jacket with rip cord. Sequential ft. marking.

Shielded version has an aluminum tape and drain shielding.

RoHS Compliant

Cables are manufactured to meet current New York City Local Law 5.

Specifications Conductor Bare Copper Insulation Solef Jacket Solef Shield Aluminum Mylar Voltage Rating 300V Temp. Rating 150oC

Applications · Fire protective signaling circuits installed in the city of New York Cond 1 2 3 4 5 6

Color Code Chart Color Black Red White Green Blue Orange

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

UNSHIELDED 300 V 150oC

781802 781820 781830 781602 781620 781630 781402 781420 781430 781202 781220 18/2 18/4 18/6 16/2 16/4 16/6 14/2 14/4 14/6 12/2 12/4 SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .635 .635 .635 .635 .635 .635 .635 .635 .635 .635 .635 .190 .295 .316 .212 .333 .357 .238 .379 .406 .272 .438 4.83 6.73 7.49 5.38 8.46 9.07 6.05 9.63 10.31 6.91 11.13 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 25 46 62 33 62 85 45 86 119 64 123

SHIELDED 300 V 150oC

781802SD 781820SD 781830SD 781602SD 781620SD 781630SD 781402SD 781420SD 781430SD 781202SD 781220SD 18/2 18/4 18/6 16/2 16/4 16/6 14/2 14/4 14/6 12/2 12/4 SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL SOL .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .025 .635 .635 .635 .635 .635 .635 .635 .635 .635 .635 .635 .194 .299 .320 .216 .337 .361 .242 .383 .410 .276 .442 4.93 7.59 8.13 5.49 8.56 9.17 6.15 9.73 10.41 7.01 11.23 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 25 46 62 33 62 85 45 86 119 64 123

* Please check with your factory representative for order minimum and current manufacturing lead time.

30

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES

SECURITY ALARM CABLES 32-35 COMMUNICATION & CONTROL CABLES 36-38

SECURITY ALARM COAXIAL BROADBAND CATVCABLES CABLES

Commercial Applications CMR/CMG FT4 Rated Unshielded

Product Description Bare copper conductors, PVC insulation, Gray PVC jacket. Sequential footage marking. Specifications Conductor Bare Copper Insulation 22 - 16 AWG .010" PVC 14 - 12 AWG .014" PVC Jacket PVC NEC Articles 22 - 16 AWG 725/CL2R 800/CMR 14 - 12 AWG 725 CL3R Voltage Rating 300 V Temp. Rating 75oC Applications · Security Systems · Intercom Systems · Sound/Audio System · Power-Limited Controls Cond 1 2 3 4 5 6 7 8 9 10 Color Code Chart Color Cond Color Black 11 Pink Red 12 Tan White Green Brown Blue Orange Yellow Purple Gray

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

82202GY 12202R 12203R 82204GY 12204R 12206R 12208R 12210R 12212R 12002R 12004R 11802R 11803R 11804R 11805R 11806R 11807R 11808R 11809R 11810R 11812R 11602R 11603R 11604R 11402R 11403R 11404R 11202R

AWG/ COND

22/2 22/2 22/3 22/4 22/4 22/6 22/8 22/10 22/12 20/2 20/4 18/2 18/3 18/4 18/5 18/6 18/7 18/8 18/9 18/10 18/12 16/2 16/3 16/4 14/2 14/3 14/4 12/2

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38

NOMINAL OD INCH

.122 .128 .135 .141 .148 .177 .192 .226 .233 .142 .165 .161 .171 .188 .207 .226 .226 .248 .269 .294 .314 .184 .196 .216 .234 .249 .276 .268

mm

3.10 3.25 3.43 3.58 3.76 4.50 4.88 5.74 5.92 3.61 4.19 4.09 4.34 4.78 5.26 5.74 5.74 6.30 6.83 7.47 7.98 4.67 4.98 5.49 5.94 6.32 7.01 6.81

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

9 10 13 16 16 27 30 41 47 13 23 18 23 32 39 56 52 59 66 74 90 25 38 51 39 56 73 57

SOL 7 7 SOL 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19 19

.015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015

32

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES SECURITY ALARM CABLES

Commercial Applications CMR/CMG FT4 Rated Shielded

Product Description Specifications Conductor Bare Copper Bare copper Insulation conductors, PVC .010" PVC insulation, Shielded 22 - 16 AWG tape with drain wire, 14 - 12 AWG .014" PVC Gray Shield Aluminum Foil PVC jacket. Jacket PVC Sequential footage NEC Articles marking. 22 - 16 AWG 725/CL2R 800/CMR Shielded version has an 14 - 12 AWG 725 CL3R aluminum tape and drain Voltage Rating 300 V shielding. Temp. Rating 75oC Applications · Security Systems · Intercom Systems · Sound/Audio System · Power-Limited Controls Cond 1 2 3 4 5 6 7 8 9 10 Color Code Chart Color Cond Color Black 11 Pink Red 12 Tan White Green Brown Blue Orange Yellow Purple Gray

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

82202SDGY 12202RSD 82204SDGY 12204RSD 12206RSD 12208RSD 12210RSD 12002RSD 12004RSD 11802RSD 11803RSD 11804RSD 11805RSD 11806RSD 11807RSD 11808RSD 11809RSD 11602RSD 11603RSD 11604RSD 11402RSD 11403RSD 11404RSD 11202RSD

AWG/ COND

22/2 22/2 22/4 22/4 22/6 22/8 22/10 20/2 20/4 18/2 18/3 18/4 18/5 18/6 18/7 18/8 18/9 16/2 16/3 16/4 14/2 14/3 14/4 12/2

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38

NOMINAL OD INCH

.125 .130 .138 .152 .179 .196 .230 .145 .168 .165 .175 .192 .211 .230 .230 .270 .272 .188 .200 .220 .238 .253 .292 .272

mm

3.18 3.30 3.50 3.86 4.55 4.98 5.84 3.68 4.27 4.19 4.45 4.88 5.36 5.84 5.84 6.86 6.91 4.78 5.08 5.59 6.05 6.43 7.42 6.91

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

14 11 15 19 29 32 44 16 26 22 30 37 45 61 57 64 71 32 42 58 53 66 77 67

SOL 7 SOL 7 7 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19 19

.015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015

35

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

33

SECURITY ALARM COAXIAL BROADBAND CATVCABLES CABLES

Commercial Applications CMP/FT6 Rated Unshielded

Product Description Bare copper conductors, Low smoke PVC insulation, Natural low smoke PVC jacket. Sequential footage marking. Specifications Conductor Bare Copper Insulation Low Smoke PVC 22 - 16 AWG .009" PVC 14 - 12 AWG .011" PVC Jacket Low Smoke PVC NEC Articles 22 - 16 AWG 725/CL2P 800/CMP 14 - 12 AWG 725 CL3P Voltage Rating 22 - 16 AWG 300 V 14 - 12 AWG 150 V Temp. Rating 75oC Applications · Security Systems · Intercom Systems · Sound/Audio System · Power-Limited Controls Cond 1 2 3 4 5 6 7 8 9 10 Color Code Chart Color Cond Color Black 11 Pink Red 12 Tan White Green Brown Blue Orange Yellow Purple Gray

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

932202 912202 912203 932204 912204 912206 912208 912210 912212 912002 912004 911802 911803 911804 911805 911806 911808 911809 911810 911812 911602 911603 911604 911402 911403 911404 911202 911204

AWG/ COND

22/2 22/2 22/3 22/4 22/4 22/6 22/8 22/10 22/12 20/2 20/4 18/2 18/3 18/4 18/5 18/6 18/8 18/9 18/10 18/12 16/2 16/3 16/4 14/2 14/3 14/4 12/2 12/4

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .46

NOMINAL OD INCH

.118 .124 .131 .136 .143 .171 .186 .218 .225 .138 .160 .157 .168 .186 .203 .222 .242 .262 .286 .296 .180 .191 .211 .222 .236 .261 .272 .308

mm

3.00 3.15 3.33 3.45 3.63 4.34 4.72 5.54 5.72 3.51 4.06 3.99 4.27 4.72 5.16 5.64 6.15 6.65 7.26 7.52 4.57 4.85 5.36 5.64 5.99 6.63 6.91 7.82

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

9 10 13 16 17 24 31 43 49 14 24 18 25 36 41 51 65 68 75 84 26 38 52 40 60 73 58 111

SOL 7 7 SOL 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19 19 19

.015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .018

34

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES SECURITY ALARM CABLES

Commercial Applications CMP/FT6 Rated Shielded

Product Description Bare copper conductors, Low smoke PVC insulation, Shielded tape with drain wire, Natural low smoke PVC jacket with rip cord. Sequential footage marking. Specifications Conductor Bare Copper Insulation Low Smoke PVC 22 - 16 AWG .009" PVC 14 - 12 AWG .011" PVC Jacket Low Smoke PVC NEC Articles 22 - 16 AWG 725/CL2P 800/CMP 14 - 12 AWG 725 CL3P Voltage Rating 22 - 16 AWG 300 V 14 - 12 AWG 150 V Temp. Rating 75oC Applications · Security Systems · Intercom Systems · Sound/Audio System · Power-Limited Controls Cond 1 2 3 4 5 6 7 8 9 10 Color Code Chart Color Cond Color Black 11 Pink Red 12 Tan White Green Brown Blue Orange Yellow Purple Gray

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

932202SD 912202SD 932204SD 912204SD 912206SD 912208SD 912210SD 912002SD 912004SD 911802SD 911803SD 911804SD 911806SD 911808SD 911809SD 911812SD 911602SD 911603SD 911604SD 911402SD 911403SD 911404SD 911202SD 911204SD

AWG/ COND

22/2 22/2 22/4 22/4 22/6 22/8 22/10 20/2 20/4 18/2 18/3 18/4 18/6 18/8 18/9 18/12 16/2 16/3 16/4 14/2 14/3 14/4 12/2 12/4

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .46 .38 .38 .38 .38 .38 .38 .38 .38

NOMINAL OD INCH

.125 .132 .126 .150 .178 .193 .225 .145 .167 .162 .175 .191 .229 .259 .269 .309 .187 .198 .218 .229 .243 .264 .263 .303

mm

3.18 3.35 3.20 3.81 4.52 4.90 5.72 3.68 4.24 4.11 4.45 4.85 5.82 6.58 6.83 7.85 4.75 5.03 5.54 5.82 6.17 6.71 6.68 7.70

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

13 13 20 20 26 37 46 17 27 23 30 37 56 66 73 99 33 45 59 54 70 86 68 121

SOL 7 SOL 7 7 7 7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 19 19 19

.015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .018 .015 .015 .015 .015 .015 .015 .015 .015

37

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

35

COMMUNICATION CONTROL CABLES BROADBAND CATV&COAXIAL CABLES

Commercial Applications 300V Product Description CMR/ CMG FT4 Rated

Specifications Conductor Bare Copper Bare copper Insulation .010" (.25 mm) PVC conductors, PVC Jacket PVC insulation, short overall twist lengths, NEC Articles 800 CMR Filler as required, Voltage Rating 300 V Shielded tape Temp. Rating 75oC with drain wire, Gray PVC jacket. Sequential footage marking. Applications · Security System · Intercom Systems · Sound/Audio System · Power-Limited Controls Pairs 1 2 3 4 Color Code Chart Color Black/Red - Red Black/White - White Black/Green - Green Black/Blue - Blue

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

12221RSD 12222RSD 12232RSD 12233RSD 122012RSD 122014RSD 120013RSD 120014RSD 11821RSD 11822RSD 118232RSD 11833RSD 118014RSD

AWG/ PAIRS

22/2 1 pr Shld/1 pr Unshld 22/2 Each Pair Shielded 22/3 Pair Overall Shield 22/3 Each Pair Shielded 22/3 2 pr Shld/1 pr Unshld 22/4 2 pr Shld/2 pr Unshld 20/3 2 pr Shld/1 pr Unshld 20/4 2 pr Shld/2 pr Unshld 18/2 1 pr Shld/1 pr Unshld 18/2 Each Pair Shielded 18/3 Overall Shield 18/3 Each Pair Shielded 18/4 2 pr Shld/2 pr Unshld

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38 .38

NOMINAL OD INCH

.211 .220 .224 .234 .179 .178 .199 .201 .262 .281 .289 .299 .219

mm

5.36 5.59 5.69 5.94 4.55 4.52 5.05 5.11 6.65 7.14 7.34 7.59 5.56

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

18 21 26 33 31 34 37 46 34 41 52 55 69

7 7 7 7 7 7 7 7 7 7 7 7 7

.015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015 .015

36

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES COMMUNICATION & CONTROL CABLES

Commercial Applications 600V Product Description Direct Burial/VNTC Bare copper PLTC/CL3/FPL Rated conductors, PVC/

NYLON insulation, Cabled together, Filler as required, Aluminum polyester foil with drain wire, Black PVC jacket. Sequential footage marking. Specifications Conductor Bare Copper Insulation PVC/NYLON Jacket PVC NEC Articles 340/725/760 Voltage Rating 600V Temp. Rating 25oC to 90oC Dry 75oC Wet Applications · Industrial Signaling · Process Control Circuits · Class 1 Circuits · Non PowerLimited Fire Protective Cond 1 2 3 4

K1

Color Code Chart Color Black White Red Green Cond 1 2 3 4

K2

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

Color Black Red Blue Orange

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

Unshielded

6802Q 6804Q 6602Q 6604Q 6402Q 6202Q 18/2 18/4 16/2 16/4 14/2 12/2 7 7 7 7 7 7 .047 .047 .047 .047 .047 .047 1.19 1.19 1.19 1.19 1.19 1.19 .284 .314 .295 .337 .332 .355 7.21 7.98 7.49 8.56 8.43 9.02 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 36 55 44 72 60 80

Shielded

6802SDQ 6804SDQ 6602SDQ 6604SDQ 6402SDQ 6202SDQ 18/2 18/4 16/2 16/4 14/2 12/2 7 7 7 7 7 7 .047 .047 .047 .047 .047 .047 1.19 1.19 1.19 1.19 1.19 1.19 .288 .317 .299 .341 .336 .359 7.32 8.05 7.59 8.66 8.53 9.12 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 38 56 47 72 60 81

39

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

37

COMMUNICATION CONTROL CABLES BROADBAND CATV&COAXIAL CABLES

Industry Equals

Product Description Tin copper conductors, PVC insulation, short overall twist lengths, Filler as required, Shielded tape with drain wire, Gray PVC jacket. Sequential footage marking. Specifications Conductor Tinned Copper Insulation Equal to competitor Jacket Equal to competitor NEC Articles 800 CMR 14-12 AWG CL2 Voltage Rating 300 V Temp. Rating 75oC Applications · Security System · Intercom Systems · Sound/Audio System · Power-Limited Controls Color Code Chart *Equal to competitor

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

22002TSD Equal to Belden 8761 22003TSD Equal to Belden 8771 22022TSD Equal to Belden 8723 22033TSD Equal to Belden 8777 20002TSD Equal to Belden 8762 20003TSD Equal to Belden 8772 318004SD Equal to Belden 9418 21803TSD Equal to Belden 8770 21802TSD Equal to Belden 8760 21602SD Equal to Belden 8719 14002TSD Equal to Belden 8720 21202SD Equal to Belden 8718

AWG/ COND

22/2

STRAND

OUTER JKT THICKNESS INCH mm

.64

NOMINAL OD INCH

.175

mm

4.44

AVAILABLE PUT-UPS

500'/1000'

SHIP WT / 1M'

18

7x30 TC

.025

22/3

7x30 TC

.033

.84

.199

5.05

500'/1000'

24

22/4

7x30 TC

.025

.64

.160

4.06

500'/1000'

19

22/6

7x30 TC

.025

.64

.273

6.93

500'/1000'

42

20/2

7x28 TC

.028

.71

.204

5.18

500'/1000'

23

20/3

7x28 TC

.033

.84

.218

5.54

500'/1000'

32

18/4

19/30 TC

.035

.89

.245

6.22

500'/1000'

49

18/3

16x30 TC

.033

.84

.246

6.25

500'/1000'

39

18/2

16/30 TC

.028

.71

.222

5.64

500'/1000'

26

16/2

19x29 TC

.032

.81

.313

7.95

500'/1000'

49

14/2

19x27 TC

.035

.89

.355

9.02

500'/1000'

71

12/2

19x25 TC

.040

1.02

.400

10.2

500'/1000'

100

38

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES

REPEL cables are ADC's proven solution for your water blocking needs They are UL Listed and meet the required flame tests to be used indoors as well as outdoor applications eliminating the need for two different cables to complete your job. Has your cable been built to REPEL the moisture present in outdoor environments? Get the protection you need with the name and quality you trust. Get REPEL from Advanced Digital Cable REPEL BRAND COMMUNICATION CABLES 40-42 REPEL BRAND COAXIAL CABLES 43

REPEL COMMUNICATION CABLES BROADBAND CATV COAXIAL CABLES

Multiple Pairs Water/UV Resistant Direct Burial CM/CL3 Rated RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL. Product Description Specifications Conductor Tinned Copper Tinned copper Insulation .010" (.25 mm) PVC conductors, PVC Jacket PVC insulation, short overall twist lengths, NEC Articles 800 and 725 Water block Shielded Voltage Rating 300 V tape with drain wire, Temp. Rating 90oC Gray PVC jacket. Sequential footage marking. Applications · Security System · Intercom Systems · Sound/Audio System · Power-Limited Controls Color Code Chart *See Below

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

Multiple Conductors

22223SDWB 12223SDWB 22221SDWB 12221SDWB 12021SDWB 12023SDWB 22/3 2 shld 1 unshld 22/3 2 shld 1 unshld 22/4 2 shld 2 unshld 22/4 2 shld 2 unshld 20/4 2 shld 2 unshld 20/3 2 shld 1 unshld SOL 7 SOL 7 7 7 .025 .025 .025 .025 .025 .025 .64 .64 .64 .64 .64 .64 .215 .230 .220 .235 .266 .263 5.46 5.84 5.59 5.97 6.76 6.68 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 18 18 24 24 28 22

Individually Shielded Pairs

12222SDWB 12224SDWB

22/2pr Each Pair Shielded 22/4pr Each Pair Shielded

7 7

.025 .025

.64 .64

.380 .427

9.65 10.85

500'/1000' 500'/1000'

23 41

Multiple Conductors

Conductors Shielded 1. 2. Unshielded 3. 4. White Green Black Red Color

Individually Shielded Pairs

Pairs 1. 2. 3. 4. Color Black/Red-Red Black/White-White Black/Green-Green Black/Blue-Blue

40

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES REPEL COMMUNICATION CABLES

Shielded/Unshielded CM/CL3 Rated Water block/Sunlight Resistant RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL. Product Description Tinned copper conductors, PVC insulation, short overall twist lengths, Water block tape, Shielded tape with drain wire, Gray PVC jacket. Sequential footage marking. Specifications Conductor Tinned Copper Insulation .010" (.25 mm) PVC Jacket PVC NEC Articles 800 and 725 Voltage Rating 300 V Temp. Rating 90oC Applications · Security System · Intercom Systems · Sound/Audio System · Power-Limited Controls Pairs 1 2 3 4 5 6 Color Code Chart Color Black Red White Green Brown Blue

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

Unshielded

2204WB 1802WB 1602WB 22/4 18/1pr 16/1pr SOL 7 7 .025 .025 .025 .64 .64 .64 .194 .194 .228 4.95 4.93 5.79 500'/1000' 500'/1000' 500'/1000' 28 31 39

Shielded

1202TSDWB 1222TSDWB 1202TSDWB 1802TSDWB 1806TSDWB 22/1pr 22/1pr 20/1pr 18/1pr 18/6 SOL 7 7 7 7 .025 .025 .025 .025 .025 .64 .64 .64 .64 .64 .200 .205 .220 .235 .323 5.12 5.21 5.59 5.97 8.20 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 21 21 24 34 69

The REPEL brand is Advanced Digital Cable's proven solution for your water blocking needs REPEL cables are first constructed using a premium grade jacket compound which is flame retardant, sunlight resistant and water resistant and has been developed to be durable in outdoor and direct burial applications. In addition to the jacket REPEL cables utilize a superior water-blocking tape, rather than the messy gel, which swells to absorb any moisture that is present The special formulated tape stops water in its tracks by blocking migration of moisture throughout the cable REPEL cables are UL Listed and meet the required flame tests to be used indoors while maintaining the durability and water resistance required for outdoor applications This unique construction eliminates the need for two different cables to complete your job Moisture of any kind can cause electrical failure, signal loss and deterioration of the cable. REPEL cables have proven to perform when submerged in water while the standard cables have been left all wet. Has your cable been built to REPEL the moisture present in outdoor environments? Get the protection you need with the name and quality you trust. Get REPEL from Advanced Digital Cable

43

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

41

REPEL COMMUNICATION CABLES BROADBAND CATV COAXIAL CABLES

Multiple Conductor 300V PLTC/Water block/ Sunlight Resistant CL3/FPL Rated

Product Description Bare copper conductors, PVC/ NYLON insulation, Cabled together, Water block tape, Aluminum polyester foil with drain wire, Black PVC jacket. Sequential footage marking. Specifications Conductor Bare Copper Insulation PVC/NYLON Jacket PVC NEC Articles 725/760 Voltage Rating 300V Temp. Rating 25oC to 90oC Dry 75oC Wet Applications · Low Voltage Process Control Circuits ·Power-Limited Circuits · Power-Limited Fire Protective Cond 1 2 3 4 Color Code Chart Color Black Red Brown Blue

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

Unshielded

6802WB 6602WB 6402WB 6202WB 18/2 16/2 14/2 12/2 7 7 7 7 .040 .040 .040 .040 1.02 1.02 1.02 1.02 .270 .295 .310 .340 6.86 7.49 7.87 8.64 500'/1000' 500'/1000' 500'/1000' 500'/1000' 35 41 64 89

Shielded

6802SDWB 6602SDWB 6402SDWB 6202SDWB 18/2 16/2 14/2 12/2 7 7 7 7 .040 .040 .040 .040 1.02 1.02 1.02 1.02 .310 .328 .350 .375 7.87 8.33 8.89 9.53 500'/1000' 500'/1000' 500'/1000' 500'/1000' 39 45 75 103

42

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES REPEL COAXIAL CABLES

HDTV/CCTV/CATV

PART NO. UL/ NOMINAL COND. ETL CORE (STRAND) OD & TYPE NEC NOM. DCR TYPE INCH mm SHIELD MTRL NOM DCR NOMINAL OD INCH mm NOM. NOMINAL NOMINAL NOM. VEL. ATTENUATION IMP. OF CAPACITANCE dB/ dB/ PROP. pF/FT pF/m MHz 100 FT. 100 m

See Chart Page 50

RG 59/U Direct Burial 20 AWG Solid .032" BC 95% TC Braid Shield Black Sunlight Resistant PVC Jacket CM 20 AWG .142 3.61 AL Foil + .242 6.15 75 83% 16.2 53.1 2159DB

SDI/HDTV Digital Video 75oC (solid) .032" BC 10.0/M' 32.8/km TC Braid 95% Shield Coverage 3.8/M' 12.5/km

FPE

RoHS

RG 59 Direct Burial 20 AWG Solid .032" BC 95% BC Braid Shield Black Sunlight Resistant PVC Jacket 20 AWG .142 3.61 BC Braid .240 6.10 75 82% 16.2 53.1 4-4593DB CM

75oC (solid) .032" BC FPE with Tape 95% Shield Coverage

See Chart Page 50

RoHS

RG 6 Direct Burial 18 AWG Solid .040" BC 60% AL Braid Shield Black Sunlight Resistant PVC Jacket 18 AWG .180 4.57 Bond-X AL .266 6.76 75 82% 16.2 53.1 4-4068DB CM

75oC (solid) .040" BC FPE Foil + AL Braid 65% Shield Coverage

See Chart Page 50

RoHS

RG 6 Direct Burial 18 AWG Solid .040" BC 95% BC Braid Shield Black Sunlight Resistant PVC Jacket 18 AWG .180 4.57 Bond-X AL .288 7.32 75 83% 17.3 56.7 4-4006DB CM

80oC (solid) .040" BC 7.5/M' 24.6/km FPE with Tape Foil + BC Braid 95% Shld Coverage 2.0/M' 6.6/km

See Chart Page 50

RoHS

Siamese RG 6 18 AWG Solid .040" BC 95% BC Braid Shield + 16 AWG (7 Str.) BC 2 Conductor Black + White PVC CM 18 AWG .180 4.57 BC Braid .266 6.76 75 82% 16.2 53.1 See Chart 9908DB

75oC (solid) .040" BC FPE .066 PVC 1.68 95% Shield Coverage Unshld x .460 x 11.68 Page 50

RoHS

16 AWG (7 Str. BC) 2 Conductor

45

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

43

BROADBAND CATV COAXIAL CABLES

PREMIUM AUDIO CABLES 45 CATEGORY 5E 350 MHz CABLES 46 CATEGORY 6E 550 MHz CABLES 47 HOME AUTOMATION CABLES 48 LANDSCAPE CABLES 49

BROADBAND CATV COAXIAL CABLES PREMIUM AUDIO CABLES

Residential/Commercial Applications CMR/CMG FT4 Rated Unshielded Product Description

High strand, super flexible, bare copper conductors, PVC insulation, PVC jacket. Sequential footage marking. Applications · Intercom/PA Systems · Home Theater Systems · Sound/Audio Systems · Stadium & Arena Speaker Systems Cond 1 2 3 4

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

Specifications Conductor HS Bare Copper Insulation 18 - 16 AWG .015" (.381mm) PVC 14 - 12 AWG .020" (.508mm) PVC Jacket PVC NEC Articles 18 - 16 AWG 800 CMR 14 - 12 AWG 725 CL3R Voltage Rating 300 V Temp. Rating 75oC

Color Code Chart Color Black White Red Green

Available Jacket Colors Blue, Green, White, Black, Yellow, Gray.

Some colors may require minimum order quantities

PART NO.

32182 32184 32162 32164 32142 32144 32122 32124

AWG/ COND

18/2 18/4 16/2 16/4 14/2 14/4 12/2 12/4

STRAND

OUTER JKT THICKNESS INCH mm

.38 .38 .38 .38 .38 .46 .46 .46

NOMINAL OD INCH

.184 .216 .208 .244 .260 .313 .302 .357

mm

4.67 5.49 5.28 6.20 6.60 7.95 7.67 9.07

AVAILABLE PUT-UPS

500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000' 500'/1000'

SHIP WT / 1M'

21 37 28 51 43 81 64 121

42 42 65 65 105 105 168 168

.015 .015 .015 .015 .015 .018 .018 .018

CLARIFY brand cables are Advanced Digital Cable's proven solution for your high end audio needs. CLARIFY cables are first constructed using a premium grade copper which is 98% pure oxygen free for maximum conductivity and corrosion resistance. CLARIFY cables utilize a high strand conductor for maximum flexibility and true accurate signal transfer. Advanced Digital Cable uses premium compounds for insulating and jacketing which provide low attenuation and maximum flexibility while remaining easy to pull and strip. Every component in an audio system is critical and CLARIFY cables have been designed to reduce noise and CLARIFY the signal. Has your cable been built to deliver crystal clear audio? Are you getting the pure sound the components are producing? Get your audio signal clarified with the name and quality you trust. Get CLARIFY from Advanced Digital Cable.

47

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

45

CATEGORY 5E 350 COAXIAL CABLES BROADBAND CATVMHz CABLES

Communications Cable CMR, FT4 / CMP FT6 Meets TIA/EIA-568-B.2

Product Description RISER BC conductors, FRPE Insulation, 4 UTP, PVC jacket, Footage markings. PLENUM BC conductors, FEP Insulation, 4 UTP, Low Smoke PVC Jacket, Footage markings. Specifications Conductor Bare Copper Insulation Riser FRPE .190mm Plenum FEP .180 mm Jacket Riser PVC Plenum Low Smoke PVC NEC Articles CMR, CMP Voltage Rating 300 V Temp. Rating 75oC SRL 350 MHz 10.6 dB Applications · Analog & Digital Voice Systems · Intercom Systems · Security (CCTV) Systems · Up To 350 Mb/s Cable · High Speed Network Connections Pair 1 2 3 4 Color Code Chart Color White/Blue Stripe & Blue White/Orange Stripe & Orange White/Green Stripe & Green White/Brown Stripe & Brown

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

RISER RATED

53424RB 53424RG

Blue Grey

24/4 24/4 24/4

SOL SOL SOL

.032 .032 .032

.42 .42 .42

.214 .214 .214

5.44 5.44 5.44

1000' RIB 1000' RIB 1000' RIB

23 23 23

53424RW White

PLENUM RATED

53424PW

White

24/4

SOL

.022

.55

.200

5.08

1000' RIB

23

ATT FREQUENCY MAX (MHz) (dB/100m)

NEXT MIN (dB)

ACR MIN (dB)

PS. NEXT MIN (dB)

PS ACR MIN (dB)

ELFEXT MIN (dB/100m)

PS. ELFEXT MIN (dB/100m)

R.L. MIN (dB)

1 4 8 10 16 20 25 31.25 62.5 100 155 200 240 300 350

2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0 28.1 32.4 36 41 44.9

68.3 59.3 54.8 53.3 50.3 48.8 47.3 45.9 41.4 38.3 35.5 33.8 32.6 31.2 30.1

66.3 55.2 49.0 46.8 42.1 39.5 36.9 34.2 24.4 16.3 7.4 1.4 -

66.3 57.3 52.8 51.3 48.3 46.8 45.3 43.9 39.4 36.3 33.5 31.8 30.6 29.2 28.1

64.3 53.2 47.0 44.8 40.1 37.5 34.9 32.2 22.4 14.3 5.4 0 -

63.8 51.7 45.7 43.8 39.7 37.8 35.8 33.9 27.8 23.8 20.0 17.7 16.2 14.2 12.9

60.8 48.7 42.7 40.8 36.7 34.8 32.8 30.9 24.8 20.8 17.0 14.7 13.2 11.2 9.9

20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.4 16.8 16.3

46

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES CATEGORY 6E 550 MHz CABLES

Communications Cable CMR, FT4 / CMP FT6 Meets TIA/EIA-568-B.2-1

Product Description RISER BC Cond., FRPE Insulation, 4 UTP, FRPE Isolator Seporator, PVC Jkt, Ft markings. PLENUM BC Cond., FEP Insulation, 4 UTP, FRPE Isolator Separator Low Smoke PVC Jkt, Ft markings. Specifications Conductor Bare Copper Insulation Riser FRPE .205mm Plenum FEP .190 mm Jacket Riser PVC Plenum Low Smoke PVC NEC Articles CMR, CMP Voltage Rating 300 V Temp. Rating 75oC SRL 550 MHz 8.6 dB Applications · Analog & Digital Voice Systems · Intercom Systems · Security (CCTV) Systems · High Speed Network Connections Pair 1 2 3 4 Color Code Chart Color White/Blue Stripe & Blue White/Orange Stripe & Orange White/Green Stripe & Green White/Brown Stripe & Brown

RoHS Compliant

Cables are manufactured to meet current NEC guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

AWG/ COND

STRAND

OUTER JKT THICKNESS INCH mm

NOMINAL OD INCH mm

AVAILABLE PUT-UPS

SHIP WT / 1M'

RISER RATED

55424RB (Blue) 55424PW (White) 23/4 23/4 SOL SOL .032 .022 .42 .55 .235 .224 5.97 5.69 1000' RIB 1000' RIB 35 35

PLENUM RATED

PS. NEXT MIN (dB) PS ACR MIN (dB) PS. ELFEXT MIN (dB/100m)

ATT FREQUENCY MAX (MHz) (dB/100m)

NEXT MIN (dB)

ACR MIN (dB)

ELFEXT MIN (dB/100m)

R.L. MIN (dB)

1 4 8 10 16 20 25 31.25 62.5 100 155 200 250 300 400 550

2.0 3.8 5.4 6.0 7.6 8.5 9.6 10.7 15.5 19.9 25.3 29.2 33.0 36.6 43.2 52.0

75.3 66.3 61.8 60.3 57.3 55.8 54.3 52.9 48.4 45.3 42.5 40.8 39.3 38.2 36.3 34.2

73.3 62.5 56.4 54.3 49.7 47.3 44.8 42.2 32.9 25.4 17.2 11.6 6.3 1.6 -

73.3 64.3 59.8 58.3 55.3 53.8 52.3 50.9 46.4 43.3 40.5 38.8 37.3 36.2 34.3 32.2

71.3 60.5 54.4 52.3 47.7 45.3 42.7 40.2 30.9 23.4 15.2 9.6 4.3 0 -

67.8 55.7 49.7 47.8 43.7 41.7 39.8 37.9 31.8 27.8 23.9 21.7 19.8 18.2 15.7 12.9

64.8 52.7 46.7 44.8 40.7 38.7 36.8 34.9 28.8 24.8 20.9 18.7 16.8 15.2 12.7 9.9

20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.3 16.8 15.9 14.9

49

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

47

BROADBAND CATV COAXIAL CABLES HOME AUTOMATION CABLES

CM/CL3 CMR/CL3R

Part Number Components Description Jacket Color dB/ dB/ & Nom. OD MHz 100 FT. 100 m INCH

9925 9924 9923

Two RG 6 Quad Shield Cables Two CAT 5E UTP Cables One RG 6 Quad Shield Cable One CAT 5E UTP Cables Two RG 6 Quad Shield Cable One CAT 5E UTP Cable

SHIELD MTRL NOM DCR

Bond-X AL Foil + AL Braid 40% + 60% Shld Coverage 4.8/M' 15.7/km

CATV/DSS Quality 18 AWG BCCS/60% braid /foil/40% braid CAT5E 350MHz 24/4 Pair CATV/DSS Quality 18 AWG BCCS/60% braid /foil/40% braid CAT5E 350MHz 24/4 Pair CATV/DSS Quality 18 AWG BCCS/60% braid /foil/40% braid CAT5E 350MHz 24/4 Pair

NOM. NOMINAL NOM. VEL. IMP. OF CAPACITANCE PROP. pF/FT pF/m

75 83% 16.2 53.1

Blue .687 Blue .540 Blue .657

NOMINAL COND. CORE (STRAND) OD & TYPE NOM. DCR INCH mm

18 AWG (solid) .040" BCCS 28.0/M' 91.9/km .180 FPE 4.57

NOMINAL OD INCH

.298

mm

7.57

COND. (STRAND)

24/4 SOL

OUTER JKT THICKNESS INCH

.032

NOMINAL OD INCH

.214

mm

.42

mm

5.44 PS. NEXT MIN (dB) 66.3 57.3 52.8 51.3 48.3 46.8 45.3 43.9 39.4 36.3 33.5 31.8 30.6 29.2 28.1 PS ACR MIN (dB) 64.3 53.2 47.0 44.8 40.1 37.5 34.9 32.2 22.4 14.3 5.4 0 PS. ELFEXT MIN (dB/100m) 60.8 48.7 42.7 40.8 36.7 34.8 32.8 30.9 24.8 20.8 17.0 14.7 13.2 11.2 9.9

FREQUENCY (MHz) 1 4 8 10 16 20 25 31.25 62.5 100 155 200 240 300 350

ATT MAX (dB/100m)

2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0 28.1 32.4 36 41 44.9

NEXT MIN (dB) 68.3 59.3 54.8 53.3 50.3 48.8 47.3 45.9 41.4 38.3 35.5 33.8 32.6 31.2 30.1

ACR MIN (dB) 66.3 55.2 49.0 46.8 42.1 39.5 36.9 34.2 24.4 16.3 7.4 1.4 -

ELFEXT MIN (dB/100m) 63.8 51.7 45.7 43.8 39.7 37.8 35.8 33.9 27.8 23.8 20.0 17.7 16.2 14.2 12.9

R.L. MIN (dB)

20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.4 16.8 16.3

48

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES

Underground Low Energy Circuit

Product Description Bare Copper Conductors, Black PVC Jacket in Flat Parallel Construction, Polarity Identified by Surface Ridges. Specifications Conductor Bare Copper Jacket PVC Voltage Rating 150 V Temp. Rating 60oC

LANDSCAPE CABLES

Applications · Indoor/Outdoor · Above/Below Ground · Landscape Lighting Systems · Low Voltage accent lighting · Security Systems Color Code Chart Conductors are all black Polarity Identified by Surface Ridges

RoHS Compliant

Cables are manufactured to meet current industry guidelines and are verified by outside standards organizations including UL and ETL.

PART NO.

1114 1112 1110 1108

AWG/ COND

14/2 12/2 10/2 8/2

STRAND

INSULATION THICKNESS INCH mm

1.14 1.14 1.14 1.52

NOMINAL OD INCH

.165 .186 .208 .248

mm

.340 .382 .426 .568

AVAILABLE PUT-UPS

500'/1000'/2500' 500'/1000'/2500' 500'/1000'/2500' 500'/1000'/2500'

SHIP WT / 1M'

54 68 96 162

41/30 65/30 104/30 168/30

.045 .045 .045 .060

51

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

49

REFERENCE CATV COAXIAL BROADBANDINFORMATION CABLES

Attenuation vs. Frequency for Broadband Coaxial Products

Series 59 Frequency UL/ COND. ETL PART Point (STRAND) Nominal Nominal Maximum Maximum NEC NO. (MHz) dB/100 Ft. dB/100m dB/100 Ft. dB/100m NOM. DCR

TYPE 55 5 1.84 .75 6.04 2.46 1.95 .89 6.40 2.92

Series 11 NOM. NOMINAL NOM. VEL. ATTENUATION Nominal Nominal Maximum Maximum Nominal Nominal Maximum Maximum IMP. OF dB/100 Ft. dB/100m dB/100 Ft. dB/100m dB/100 Ft. dB/100m dB/100 Ft. dB/100m PROP.

1.45 .54 4.76 1.77 1.60 .67 5.25 2.20 .91 .34 2.99 1.12 .97 .38 3.18 1.25

Series 6

3000

2250

1800

1450

1000

950

900

870

862

800

750

700

650

600

550

500

450

400

375

350

325

300

270

240

216

211

7.68 -

7.39

7.14

7.00

6.97

6.71

6.51

6.28

6.03

5.75

5.48

5.22

4.96

4.66

4.49

4.33

4.16

3.99

3.79

3.57

3.41

3.36

25.20 -

24.25

23.42

22.97

22.87

22.01

21.36

20.60

19.78

18.86

17.98

17.13

16.27

15.29

14.73

14.21

13.65

13.09

12.43

11.71

11.19

11.02

8.09 -

7.90

7.79

7.54

7.50

7.30

6.96

6.83

6.52

6.18

5.90

5.50

5.30

4.88

4.84

4.64

4.50

4.27

4.05

3.87

3.69

3.59

26.54 -

25.92

25.56

24.74

24.61

23.95

22.83

22.41

21.39

20.28

19.36

18.04

17.39

16.01

15.88

15.22

14.76

14.01

13.29

12.70

12.11

11.78

4.92 5.27 5.11

4.72

4.51

4.30

4.09

3.88

3.65

3.52

3.39

3.26

3.13

2.97

2.80

2.67

2.64

10.70 11.55 11.12

10.27

9.74

9.19

8.76

8.66

13.42 14.80 14.11

12.73

11.97

-

-

-

-

-

-

-

-

11.30

9.80

8.60

7.80

5.99

5.79

5.60

5.49

5.47

37.10

32.20

28.20

25.60

19.65

19.00

18.37

18.01

17.95

17.29

16.76

16.14

15.49

6.00 6.35 6.11

5.98

5.75

5.59

5.45

5.18

4.94

4.71

4.48

4.26

4.00

3.87

3.72

3.59

3.43

3.24

3.09

2.95

2.87

10.63 11.78 11.25

10.14

9.68

9.42

10.00 11.90

8.80

8.00

6.54

39.00

32.80

28.90

26.20

21.46

20.83

20.05

19.68

19.62

16.86

18.34

17.88

16.99

16.21

15.45

14.70

13.98

13.12

12.70

12.20

8.00

6.50

5.70

5.00

3.77

3.66

3.55

3.48

3.46

3.32

3.21

3.10

2.98

2.85

2.73

2.59

2.45

2.30

2.22

2.15

2.07

1.99

1.89

1.78

1.70

1.68

10.89 11.42 11.35

10.53

10.17

9.78

9.35

8.96

8.50

8.04

7.55

7.28

7.05

6.79

6.53

6.20

5.84

5.58

5.51

26.25

21.33

18.70

16.41

12.37

12.01

11.65

8.80

7.15

6.27

5.50

4.23

4.10

3.96

3.84

3.82

3.65

3.50

3.37

3.22

3.08

2.94

2.85

2.65

2.47

2.40

2.32

2.24

2.15

2.05

1.94

1.84

1.81

10.56 11.48 11.06

10.10

9.65

9.35

8.69

8.10

7.87

7.61

7.35

7.05

6.73

6.36

6.04

5.94

28.90

23.50

20.60

18.10

13.88

13.45

12.99

12.60

12.53

11.97

* All attenuations are nominal. Please consult factory for product specific attentuation and frequency values.

50

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES REFERENCE INFORMATION

Glossary of Abbreviations

Amp AC AL AWG AWM BC C CATV CCTV CCS CL2 CL3 CM CMA CSA dB DC ETP f F FEP FFEP FPE FPL FRPE FT4 G GHz Hz I K KHz L M MHz NCV NEC NFPA OFC p PE pF PLTC PP PU PVC RG SC SPE TC TPE TPR UL XLPE Ampere- the standard unit of measure for current. Alternating Current Aluminum American Wire Gage Appliance Wiring Material Bare Copper Capacitance or degrees Celsius Community Antenna Television - Article 820 of the National Electrical Code Closed Circuit Television Copper Clad Steel Class 2 Circuits - Article 725 of the National Electrical Code Class 3 Circuits - Article 725 of the National Electrical Code Communication Cables - Article 800 of the National Electrical Code Circular Mil Area Canadian Standards Association Decibel Direct Current Electrolytic Tough Pitch - The standard electrical grade of copper wire. Frequency Farad - The standard unit measure for capacitance. Fluorinated Ethylene-Propylene - A DuPont plastic compound in the Teflon family. Foamed Fluorinated Ethylene Propylene Foamed Polyethylene Power-Limited Fire Alarm Circuits - Article 760 of the National Electrical Code Flame Resistant Polyethylene The Canadian Standards Association's designation for their vertical flame test. Giga or 1,000,000,000 Gigahertz - One billion cycles per second. Hertz - One cycle per second. A symbol used to designate electrical current. Kilo or 1,000 Kilohertz - One thousand cycles per second. A symbol used to designate electrical inductance. Mega or 1,000,000 Megahertz - One million cycles per second. Non-contaminating polyvinyl chloride National Electrical Code - Published by the National Fire Protection Association National Fire Protection Association Oxygen Free Copper - Copper that is at least 99.99% pure. Pico or .000000000001 Polyethylene Picofarad - One billionth of a Farad Power Limited Tray Cable - Article 725 of the National Electrical Code Polypropylene Polyurethane Polyvinyl Chloride Radio Guide - The military designation for coaxial type cables. Silver Clad Solid Polyethylene Tin Clad Thermoplastic Elastomer Thermoplastic Rubber Underwriters Laboratories - An independent non-profit testing laboratory Cross-linked Polyethylene

53

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

51

REFERENCE CATV COAXIAL BROADBANDINFORMATION CABLES

Conduit Capacity Chart

Conduit Size I.D., inches Permissible Area* 0.100 0.125 0.150 0.175 0.200 0.225 0.250 0.275 0.300 0.325 0.350 0.375 0.400 0.425 0.450 0.475 0.500 0.525 0.550 0.575 0.600 0.625 0.650 0.675 0.700 0.725 0.750 0.775 0.800 0.825 0.850 0.875 0.900 0.925 0.950 0.975 1.000 1.025 1.050 1.075 1.100 1.125 1.150 1.175 1.200 1.225 1.250 1.275 1.300 1.325 1.350 1.375 1.400 1.425 1.450 1.475 1.500 0.008 0.012 0.018 0.024 0.031 0.040 0.049 0.059 0.071 0.083 0.096 0.110 0.126 0.142 0.159 0.177 0.196 0.216 0.238 0.260 0.283 0.307 0.332 0.358 0.385 0.413 0.442 0.472 0.503 0.535 0.567 0.601 0.636 0.672 0.709 0.747 0.785 0.825 0.866 0.908 0.950 0.994 1.039 1.084 1.131 1.179 1.227 1.277 1.327 1.379 1.431 1.485 1.539 1.595 1.651 1.709 1.767 1/2 .622 0.12 15 9 6 5 3 3 2 2 1 1 1 1 -

The following information is to provide a quick reference for conduit fill requirements. It is intented to be used as a general reference only.

3/4 .824 0.21 27 17 12 8 6 5 4 3 3 2 2 1 1 1 1 1 1 1 1.049 0.34 44 28 19 14 11 8 7 5 4 4 3 3 2 2 2 1 1 1 1 1 1 1 1 1 1/4 1.380 0.60 76 48 33 24 19 15 12 10 8 7 6 5 4 4 3 3 3 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1/2 1.610 0.82 103 66 46 33 25 20 16 13 11 9 8 7 6 5 5 4 4 3 3 3 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 2 2.067 1.34 170 109 75 55 42 33 27 22 18 16 13 12 10 9 8 7 6 6 5 5 4 4 4 3 3 3 3 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1/2 2.469 1.92 243 156 108 79 60 48 39 32 27 23 19 17 15 13 12 10 9 8 8 7 6 6 5 5 4 4 4 4 3 3 3 3 3 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3.068 2.95 376 240 167 122 94 74 60 49 41 35 30 26 23 20 18 16 15 13 12 11 10 9 8 8 7 7 6 6 5 5 5 4 4 4 4 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 3 1/2 3.548 3.96 503 322 223 164 125 99 80 66 55 47 41 35 31 27 24 22 20 18 16 15 13 12 11 11 10 9 8 8 7 7 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 4 4.026 5.09 648 414 288 211 162 128 103 85 72 61 52 46 40 35 32 28 25 23 21 19 18 16 15 14 13 12 11 10 10 9 8 8 8 7 7 6 6 6 5 5 5 5 4 4 4 4 4 3 3 3 3 3 3 3 3 2 2 4 1/2 4.506 6.38 812 519 360 265 203 160 129 107 90 76 66 57 50 44 40 35 32 29 26 24 22 20 19 17 16 15 14 13 12 11 11 10 10 9 8 8 8 7 7 7 6 6 6 5 5 5 5 4 4 4 4 4 4 3 3 3 3

Cable O.D. Cable Area Sq. inch inch

5 5.047 8.00 1018 652 452 332 254 201 163 134 113 96 83 72 63 56 50 45 40 36 33 30 28 26 24 22 20 19 18 16 15 14 14 13 12 11 11 10 10 9 9 8 8 8 7 7 7 6 6 6 6 5 5 5 5 5 4 4 4

*Permissible Area is based on NEC standard of 40% fill, which applies to three or more non-lead covered cables installed in the same conduit.

Example:

1. Same Cable: Find the number equal to or greater than the O.D. of the cable and then move across to find the number of cables in the appropriate conduit size. 2. Different Cables: Square the O.D. of each cable, take the sum of them and multiply it by .7854. Find the Permissible Area that is equal to or greater than the first result. Then reference the size conduit you will need.

52

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES REFERENCE INFORMATION

Voltage Drop Chart 14 12 Voltage Drop/Amps 10 8 6 4 2 0 0 50 100 150 Feet 200 250 300 350 18 AWG 16 AWG Approximate Voltage Drop at 68o F

22 AWG

20 AWG

Pulling Tensions Gauge 22 20 18 16 14 12 Maximum Pulling Tension 7 lbs. 12 lbs. 19 lbs. 30 lbs. 48 lbs. 77 lbs.

55

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

53

REFERENCE CATV COAXIAL BROADBANDINFORMATION CABLES

N.E.C. Flame Tests Plenum Cable UL 910 (NPFA 262) The UL 910 test for plenum cable has been in use since 1978. It is a modified version of the Steiner Tunnel test used to test building materials for over fifty years. Cables are mounted horizontally in a 25 foot long tunnel with a 320,000 BTU/hr. gas flame at one end and air flowing through the tunnel at 240 ft./min. Both flame spread and smoke generation are measured. It is the only test where smoke generation is measured. UL 910 is the most difficult flammability test for low-voltage cable. All plenum cable must pass this test. Any cable which passes this test is automatically assumed to pass any of the other three new tests, which are less severe and have no smoke generation requirements. Riser Cable - UL 1666 The first of the three new flammability tests is for riser cable and is designated UL 1666. This is a modification of the old UL 1581 flame test and involves a 12 foot Vertical Open Tray with a 495,000 BTU/hr. gas flame applied at the bottom for thirty minutes. Note that riser cables are used in special areas that connect one floor to another in commercial buildings and penetrate fire-rated walls and floors. General Building Wiring - UL 1581 (Vertical Tray Flame Test) The second new flammability test is for general building wire used in commercial buildings. This is wire used in areas other than plenums and risers in commercial buildings. This test is less severe than the riser cable test and consists of a vertical 8 foot open tray subjected to a 70,000 BTU/hr. flame for twenty minutes. It is similar to the UL 1581 and IEEE 383 tests. Restricted Use - VW-1 The third new flammability test is for residential wire as used in one and two family dwellings. It is a laboratory test using a Bunsen burner and a single vertical wire and has the least critical requirements of the four flammability tests. Wire passing this test may be used in conduit in nonresidential buildings, and exposed lengths up to ten feet are permitted in non-concealed spaces only. UL TYPE MPR CMR FPLR CL3R CL2R CATVR UL TYPE MP CM FPL CL3 CL2 CATV UL TYPE CMX CL3X CL2X CATVX UL TYPE MPP CMP FPLP CL3P CL2P CATVP

54

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BROADBAND CATV COAXIAL CABLES REFERENCE INFORMATION

Bare Copper Conductor AWG Chart

TYPE STRAND STRANDING* Solid 7/32 19/36 Solid 7/30 19/34 Solid 7/28 10/30 19/32 26/34 Solid 7/26 16/30 19/30 41/34 Co or Bu Co or Bu Co or Bu Bu or Eq DIAMETER in. circ. mm mils AREA sq. mm. WEIGHT lbs/M' kg/ km.

Tin

D.C. RESISTANCE 20o C

Coating Silver

M' /km.

AWG 24 22

Coating

/km.

/M'

.0201 .024 .025 .025 .030 .0315 .032 .038 .037 .040 .039

.511 404 .610 448 .635 475 .643 643 .762 700 .800 754 .813 .965 .940 1.02 .940

.205 1.22 .227 1.38 .241 1.48 .324 1.94 .355 2.19 .382 2.35 3.10 3.49 3.14 3.84 3.28 4.92 5.55 5.01 5.95 5.09 7.81 8.02 8.15 8.20 12.4 12.7 12.1 12.7 12.9

1.82 27.20 2.05 25.70 2.20 24.90 2.89 16.70 3.26 16.60 3.50 15.50 4.61 5.19 4.67 5.71 4.88 7.32 8.26 7.45 8.85 7.08 10.50 10.30 11.40 9.48 11.30 6.77 6.45 7.15 6.10 7.08 4.47 4.39 4.39 4.47 2.68 3.05 2.73 2.81

89.20 25.70 84.20 23.10 81.70 21.80 54.80 16.20 54.40 14.80 50.80 13.80 10.10 9.33 10.40 8.53 6.39 5.55 6.48 5.46 6.60 4.16 4.13 3.99 4.16 2.52 2.61 2.71 2.61 2.53

84.20 75.90 71.60 53.20 48.60 45.10 33.20 30.60 34.00 28.00 21.00 19.20 21.30 17.90 21.60 13.60 13.50 13.10 13.60

BREAK STR. LBS. 12.690 19.430

20

Co or Bu Bu Co, Bu or Eq Bu Co or Bu Bu Co, Bu or Eq Bu Bu Bu Bu Bu Cu Bu

1,020 1,111 1,000 1,216 1,290 1,620 1,770 1,600 1,900 1,627 2,426 2,601 2,600

18

16

Solid 19/.0117 26/30 65/34 Solid 7/.0242 19/.0147 41/30 Solid 7/.0305 19/.0185 65/30

.0403 .048 .0475 .050 .049 .0508 .0585 .0606 .060 .0641 .073 .074 .077

1.024 1.22 1.207 1.27 1.244 1.29 1.50 1.54 1.52

.519 .562 .507 .616 .523 .823 .897 .810 .963 .824 1.31 1.32 1.32 1.31

34.40 33.80 37.40 31.10 37.10 22.20 21.20 23.40 20.00 23.20 14.70 14.40 14.40 14.70 8.79 10.00 9.22 5.54 5.97 3.61

30.890

49.120

14

12

10

Solid 7/.0385 19/.0234 37/.0169 105/30

Co Bu Co Bu

Co Bu Bu

.1019 .116 .117 .112 .126

.0808 .092 .0925 .094

2.588 2.95 2.97 2.84 3.20

2.05 2.34 2.35 2.388

1.63 2,581 1.85 4,110 4,100 1.88 3,831 1.96 4,106 4,100 6,530 6,088 6,503

2.08 2.08 1.94 2.08 2.08 3.31 3.30 3.30 3.29 5.26 5.25 5.27 4.74 5.32

11.60 11.90 12.10 11.90

78.100

6,500 10,380 10,376 10,404 9,361

19.8 20.2 20.2 20.8 31.4 32.0 32.0 29.2 33.8

29.50 30.10 30.10 31.10

18.50 18.90 18.00 18.90 19.20

46.80 47.60 47.60 43.40 49.20

1.10

1.69 1.82

1.59 1.64 1.64 1.64 1.00 1.00 .98 1.25 .99

5.21 5.38 5.25 5.25

8.28 8.56 8.88 124.200 8.56 8.30 197.5

3.28 3.28 3.21 314.500 4.10 3.24

*Co-Concentric, Bu-Bunched, Eq-Equilay

57

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

55

BELDEN CROSS REFERENCE

The following list does not imply that the cross-referenced items are identical. Consult our catalog pages for specification of each product.

Belden Part #

1189AP 1500R 1500R 1505A 1523A 1505F 1500R 1189A

ADC Part #

4-4061QS 53424RB 8-9068QS 53424RG 2159R 2159F

Page #

4, 15 46 46 9 9 6 3 2 3 2

Belden Part #

5102UE 5102UP 5120FL 5120FJ

ADC Part #

11404R 32144

Page #

45 27 29 25 25 25 32

831402SD 81402SD 86402SD 81404SD 4-4011 81404 81402

53424RW

46

5120UL 5122UL 5200FE 513945 5122FL

5120FN

1530AP 1694A 1695A

1530A

8-9170 2106R

4-4060

4-4111

25

1829AC 1830A 1839A

1829A

8-9106

4-4061

4, 10 8, 14 5, 8 8 2, 8 11 37 37 37 11 2, 8

5200UE 5200UP 5201FE

11602RSD 11602R 32162

6, 12 33 32 45 33

4-4068

1840A 1855A 1865A

4-4061DM 2359R 2459R

4-4061M

4-4590

5201UE 5202UE 5210UN 5220FL 5220UJ 5220FJ 5202UP 5202FE

11603RSD 11604RSD 11604R 86402 32164 11603R

32

33

32 45 29 27 29 25 29 25 25 27

27082AS 27325AS 27326AS 27337AS 27338AS 27636AS 5000UE 5002UP 5020FL 5020FJ 5000UP 5000FE 27636A 27338A 27337A 27326A 27325A

27082A

6202SDQ 6802SDQ 6804SDQ 6602SDQ 6604SDQ 6402SDQ 11202R 32124 32122 6402Q 6604Q 6602Q 6804Q 6802Q

6202Q

831602SD 86602SD 831602 81602 86602 81604 81602SD

5220FN 5220UL 5222FL 5300F1

25

37 37 37 37 37

5220UN 5222UL 5300FE

81604SD 1802TSDWB 1806TSDWB 11802R 32182 11802RSD

37 37 37 37

41 41 45

5300UE 5300UP 5301FE

5300U1

33 32 33

11202RSD

33

831202SD 86202SD 81202 81202SD

45

45

32

5301UE 5302UE 5302UP 5303FE 5304FE 5302FE

11803RSD 11804RSD 11804R 32184 11803R

32 33

27 25 29 25 33

32 45

5020UL 5100UE 5100UP 5101FE 5100FE

5020FN

5303UE 5304UE 5305UE 5306UE 5307FE 5306FE 5305FE

11805RSD 11806RSD 11807RSD 11808RSD 11809RSD 11808R 11807R 11806R 11805R

33 32 33 32

11402RSD 11402R 32142

5101UE 5102FE

11403RSD 11404RSD 11403R

45

32 33

33 32 33

32

33

32

33

56

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

BELDEN CROSS REFERENCE

The following list does not imply that the cross-referenced items are identical. Consult our catalog pages for specification of each product.

Belden Part #

5307UE 5308UE 5320FJ

ADC Part #

11809R 11810R

Page #

32 32

Belden Part #

6000UE 6001FE

ADC Part #

911204SD 981202SD 911402SD 911403SD 911404SD 981402SD 981402 981404 7-9012 7-9011 987402 911404 911403 911402 981202 911204 911202

Page #

34 35 34 26

5309UE 5320FL 5320UJ

831802SD 86802SD 831802 86802 81802 81802SD

11812R

33

27 29

6002UE 6020UL 6100UE 6101UE 6102UE 6120FL 6120UJ 6102FE 6101FE 6100FE 6020FL

5320FN 5320UL 5322FL

25

5320UN 5322UL

81804SD 81806 81804

29 25

25

27

25

34 34 35

35

34

35

26

5329UL 5339B5 533945

5328UL

5326UL

5324UL

4-4006A 4-4061QS 4-4068DB 4-4068QSL 9906 4068WB 4-4068

81812

81810

81808

5339W5 5339W5 5399B5 5402FE 543945 549945 5400F1 539945

5339Q5

8, 14 12 16 2

2, 12

25

25

25

25

6120UL 6122UL 6139B8 613948 6122FL

981404SD

26 26 26 7 7

28

26

43

6200UE 6201UE 6202UE 6220FK 6220FL 6220UJ 6202FE 6201FE

6200FE

911602SD 911603SD 911604SD 987602SD 987602 911604 911603 911602

35 35 34

1202TSDWB 82204SDGY 4-4593A 9912

14 41 33 16 33

35

34 34 28 26 28

12 41

5500UE 5502FE

5500FE

5500F1

1222TSDWB 12202RSD 12202R 12203R

981602SD 981602

5501UE

32 33

6220UL 6222UL 6300UE 6301UE 6302UE 6304FE 6302FE 6301FE 6300FE 6222FL

5502UE 5504UE 5506UE 5508UE 551945 5508FE 5506FE 5504FE

12204RSD 12206RSD 12208RSD 12210RSD 12212R 12210R 12208R 12206R 12204R

32

981604SD 911802SD 911803SD 911804SD 911805 911804 911803 911802 981604

26 26

26

5509UE 5520FE

5582UE 6000FE 573945

5520UE

82202SDGY 82204GY 4-2459 82202GY

4-8449S

32 12 32

32

33

32

33

32

33

32

6303UE 6304UE 6306UE 6307UE 6309FE 6307FE 6306FE

911806SD 911808SD 911809SD 911809 911810 911808 911806

34 35 35

35

34

34

35

34

35

34

35

33

34

32 35

911202SD

12

6308UE

34 35

911812SD

34

59

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

57

BELDEN CROSS REFERENCE

The following list does not imply that the cross-referenced items are identical. Consult our catalog pages for specification of each product.

Belden Part #

6309UE 6320FK 6320FL 6320UJ

ADC Part #

987802SD 981802SD 981802 987802 911812

Page #

28 28 26 34

Belden Part #

8238 8254 8240 8237

ADC Part #

4-8211 8062A 8208

Page #

22 17

4-8058 8162B

6320UL 6322UL 6322FL

981804SD 981806 981804

6328UL 633938 633938 6339Q8 639948 643948 633948

6326UL

6324UL

981810 8-9070 8-9070

981808

3, 15 3, 15 4, 15 16 13 4,13

26

26

26

26

26

26

8268

8267

8262

8261

8259

8255

4-8058A 8058C 8211A

21 22 17

21

17

8279 8281

8214SC 8059PE 2062PE 21202SD 2062R

8213A

20 10 10 38 38 38 38 9

20

20

8-9068QS 8-9996 8-9593

8-9006A

8281B 8718 8719

6439Q8 6500FE 649948

6439C8

8-9470QS 912202SD 912203 912202 8-9992

8-9590

15 15

8723 8760

8720

22022TSD 21802TSD

14002TSD

21602SD

38

16 35

8761 8762

22002TSD 20002TSD

38 38

6501UE 6502UE 6504UE 6506UE 6508UE 6509UE 6539Y8 673948 7731A 7732A 7806R 7806A 6508FE 6506FE 6504FE 6502FE

6500UE

912204SD 912206SD 912208SD 912210SD 912210 912212 8-9459 7-9013 LR195 55424RB 4011PE 2221 8174 LL240 LL195 2111R 8-9062 912208 912206 912204

34 34 34 35 35

34

8771 8777 9077 9114 9116 8772

8770

22003TSD 22033TSD 4-4061D 4-4069 4-4061 20003TSD

21803TSD

38 38 2 38

38

2, 8 2, 8 4 3

34 13 11 34

35

34

35

9117M 9221 9201

9116R

9116P

4-4061M 2230 8158

4-4061R

8-9171

2, 8 22 17 16 17 3 17

13 11

9248 9251 9265 9258

4-4068TC 4-8282X 4-8062A 318004SD 2224DB 8216A 1408 1418 8223SC 9900 8208A

7882A 8213 8216

7881A

7808A

55424PW

47 17 4 6

47

18

18

18

9463DB 9913 9850

9418

9273

9269

38 23 18 22

20

21

82248

8218

82262

8-9068TC 8-9262

22

9913F7

18

21

58

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

WEST PENN CROSS REFERENCE

The following list does not imply that the cross-referenced items are identical. Consult our catalog pages for specification of each product.

West Penn Part #

301 302

ADC Part #

22003TSD 2159R 20003TSD 4-8062A 4011PE 86802 86602 4-4111

Page #

38 9 38 21 6 6

West Penn Part #

AQC351 AQC352

22223SDWB

ADC Part #

Page #

40 40

819

1100 1975 1130

820

AQC355

12223SDWB

AQC357 AQC358 AQC359

22221SDWB

12221SDWB 12023SDWB 12021SDWB

40

40 40 40

1980 1990 1991 1994 1995 1999

86802SD

29 29 29 29 29 29

AQC430 AQC439 AQC806 AQC815 AQC819 AQC841 D431

12222SDWB 12224SDWB 4-4006DB 2159DB 4-4593DB 4-4068DB

40 40

86602SD 86402SD 4-4061 86402

3, 43 43 43

6100

86202SD 4-4061D

6150 6170 6300 6350

2, 8 2 2

29

D303/303 D510 D975 D980 D990

21803TSD

43 38 38 38 27 27 27 27

4-4061QS 4-4068TC 8-9068TC 89159 2106R

4-4060

2, 8

22033TSD 22022TSD 831802SD 831802 831602

25841 77292 77291

25819

6373

3, 10 9 3

77293

20002TSD 21602SD

22002TSD

77294

21802TSD 14002TSD 21202SD 6802WB 6602WB 6402WB 6202WB 8-9106

38

38

4

D995

D991

38

HN5161

HD825

D999

831402SD 2459R 9924 9923

831602SD

831202SD

27 27 48 11

77295

38

HN5162 P806

256350 AQ224 AQ225 AQ226 AQ227 AQ293 AQ294

77296

38 4

HN5262 TC2975

38 42 42 42 42 42

TC2977 TC2980 TC2982 TC2990 TC2991 TC2992

6802SDQ 6802Q 6804Q 6602Q

2062PE

9925

48 48 10

6804SDQ

37

37 37 37 37 37 37 37 37 37 37

6802SDWB

6602SDQ 6604SDQ 6402SDQ 6202SDQ 6202Q 6402Q 6604Q

AQ295

6602SDWB

AQC224

AQ296

6402SDWB 1802WB

42

6202SDWB 1602WB 9908DB

42

TC2993

42

TC2994

AQC225

41

TC2995

AQC2806 AQC291 AQC290

AQC240

2204WB

41

TC2998

41 43

TC2999

37

AQC3186

AQC293

AQC292

1806TSDWB

1802TSDWB

1202TSDWB

1222TSDWB

1202TSDWB

41

41

41

41

41

61

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

59

CAROL CABLE CROSS REFERENCE

The following list does not imply that the cross-referenced items are identical. Consult our catalog pages for specification of each product.

Carol Part #

C0471 C0472 C0473 C0474 C0475 C0476 C0491 C0492 C1108 C1117 C1154 C1155 C1156 C1158 C1160 C1164 C1166 C1176 C1178 C1180 C1352 C2514 C2524 C2526 C2528 C2534 C2535 C2536 C2537 C2538 C2539 C2543

ADC Part #

831802 831802SD 831602 831602SD 831402SD 831202SD 831402 831202 4-8282X 8158 8208 8058C 8174 2221 8211A 4-8062A 4-8058 8213A 4-8058A 1418 22022TSD 22002TSD 20002TSD 22003TSD 20003TSD 21802TSD 21803TSD 21602SD 11603RSD 14002TSD 21202SD 318004SD 911804 911803 911806 911808 911602 987802SD 987602SD 911602SD 987402SD 987202SD 987802 987602 987402 987202 911604SD 8-9262

Page #

27 27 27 27 27 27 27 27 17 17 17 20 17 22 22 21 17 20 17 18 38 38 38 38 38 38 38 38 33 38 38 38 34 34 34 34 34 28 28 35 28 28 28 28 28 28 35 21

Carol Part #

C3523 C3524 C5025 C5039 C5774 C5775 C5776 C5778 C5785 C5814 C5816 C5826 C5886 C6040 C8025 E1000S E1002S E1003S E1004S E1006S E1008S E1010S E1012S E1032S E1033S E1034S E1036S E1038S E1040S E1041S E1042S E1044S E1052S E1054S E1062S E1502S E1504S E1506S E1512S E1514S E1522S E1524S E1532S E2000S E2002S E2004S E2006S E2008S

ADC Part #

8-9068TC 8-9171 4011PE 4-4111 4-4069 4-4061 4-4060 4-4068TC 4-4061QS 2106R 2062R 4-4061DM 4-4061R 22033TSD 9900 82202GY 12202R 12203R 12204R 12206R 12208R 12210R 12212R 11802R 11803R 11804R 11806R 11808R 11810R 11812R 11602R 11604R 11402R 11404R 11202R 81802 81804 81806 81602 81604 81402 81404 81202 82202SDGY 12202RSD 12204RSD 12206RSD 12208RSD

Page #

4 4 6 6 2 2 2 3 2 3 10 8 3 38 16 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 32 25 25 25 25 25 25 25 25 33 33 33 33 33

Carol Part #

E2032S E2033S E2034S E2036S E2042S E2062S E2102S E2104S E2106S E2108S E2202S E2203S E2204S E2206S E2243S E2252S E2502S E2504S E2522S E2524S E2532S E2534S E2542S E3002S E3003S E3004S E3006S E3008S E3032S E3043S E3044S E3052S E3054S E3504S E3506S E3512S E3514S E3522S E3524S E3532S E3602S E3604S

ADC Part #

11802RSD 11803RSD 11804RSD 11806RSD 11602RSD 11202RSD 912202SD 912204SD 912206SD 912208SD 911802SD 911803SD 911804SD 911806SD 911603SD 911402SD 81802SD 81804SD 81602SD 81604SD 81402SD 81404SD 81202SD 912202 912203 912204 912206 912208 911802 911603 911604 911402 911404 981804 981806 981602 981604 981402 981404 981202 981802SD 981804SD

Page #

33 33 33 33 33 33 35 35 35 35 35 35 35 35 35 35 25 25 25 25 25 25 25 34 34 34 34 34 34 34 34 34 34 26 26 26 26 26 26 26 26 26

C3113/E3034S C3120/E3033S C3121/E3036S C3122/E3038S C3127/E3042S C3167 C3168 C3169/E2242S C3172 C3174 C3240 C3241 C3244 C3246 C3341/E2244S C3520

E3612S E3614S E3624S E3632S

981602SD 981604SD 981404SD 981202SD

26 26 26 26

60

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

ADC PART NUMBER INDEX

Part #

1108 1112 1110

Page #

49 49

11202RSD 11402RSD 11403RSD 11404RSD 11602RSD 11603RSD 11604RSD 11802R 11604R 11603R 11602R 11404R 11403R 11402R

11202R

1114

33 33 33

32

33

32

49

49

1202TSDWB 122014RSD 12202RSD 12203R 12204R 12202R 122012RSD

1202TSDWB

12023SDWB

12021SDWB

12004RSD

Part #

Page #

40 33

36

36

41

41

40

32

33 32 33 33 33 32 32 32

32

22033TSD 2204WB 2214DB 2221

22022TSD

22003TSD

22002TSD

21803TSD

21802TSD

21602SD

Part #

Page #

38 38

38

38

38

38

38

4-4061DM 4-4061M 4-4061R 4-4068 4-4068 4-4061M

4-4061D

Part #

Page #

8 8

4-4061QS

41 23 22 40

4-4068DN 4-4068QSL 4-4068TC 4-4106A 4-4590 4-4111 4-4069 4-4068QS

43 14 14 3 2 6 5 8 5 2

14

8

3

2

8

2

32

32 32 32

12204RSD 12206RSD 12208RSD 12210RSD 12221RSD 12212R 12210R 12208R 12206R

32

22223SDWB 2224DB 2262FX 2400PE 318004SD 32124 32122 2459R 2359R 2230

22221SDWB

40 23 22 10 11

33

33

118014RSD 11802RSD 11803RSD 11804RSD 11805RSD 11806RSD 11807RSD 11808RSD 11809RSD 11810R 11812R 11809R 11808R 11807R 11806R 11805R 11804R 11803R

33 36 32

33 36

19 38 11

4-4590 4-4591

32

33 33 33

32

33

32

33

32

33

32

33

12221SDWB 12222SDWB 12222RSD

1222TSDWB 12233RSD 14002TSD 1418 1408 12232RSD

12224SDWB

12223SDWB

32

38 18 41

36

36

41

40

40

40

36

40

32184 4000

32182

32164

32162

32144

32142

45 45 45

45

45

4-4593DB 4-8058 4-4599

4-4593A

43 17 5

12

18

4000PE 4061PE 4111PE 4011PE

19 6 3

45

45

45

4-8062A 4-8282X 4-8211

4-8058A

19

53424RW 55424PW 55424RB 6202Q

53424RG

53424RB

4-8449S

46 46 47 47 46

12

17

22

21

17

32

32 36 32

33

32

1802TSDWB 1806TSDWB 20002TSD 20003TSD 2062PE 2062R 2106R 2106R 21202SD 2159DB 2159R 2159F 2111R 1802WB

1602WB

41

4068WB 4-2214BE 4-2459

12 23 6

38 38 10 3

41

41

4-2224FX 4-4006A

23 12 12 43 12 2 2 6 3 2

6202SDWB 6202WB 6402Q

6202SDQ

42 37 37 42 42 37 37 42

37

37

11821RSD

118232RSD 120013RSD 120014RSD 12002RSD 12004R 12002R 11833RSD

11822RSD

36 36 36 36 36 32

10 10

4-4006DB 4-4006DB 4-4011 4-4011

4-4006A

6402SDWB 6402WB 6602Q

6402SDQ

38 9

11

33

43 9

4-4060

4-4061

6602SDWB 6602WB 6604Q

6602SDQ

42

32

4-4061D

4-4061

8

42

2

6604SDQ

37

37

63

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Phone: (800) 343 2579 · Fax: (828)389 3922 · www.adcable.com

61

ADC PART NUMBER INDEX

6802SDQ 6802WB 6804Q 6802Q

Part #

Page #

37 37

Part #

81604 8174 81602

Page #

25 17 25

6802SDWB

42

42

8162B 8174

21 20

8-9068QS 8-9070

8-9068QS 8-9068TC 8-9070

Part #

Page #

15 3 4 4

911809SD 911810 911812

Part #

Page #

34 35

987602SD 987802SD 9900 9906 987802

Part #

Page #

28 28

6804SDQ 781202SD 781220SD 781402SD 781420SD 781430SD 781602SD 781620SD 781630SD 781802SD 781820SD 781830SD 7-9011 7-9011 781830 781820 781802 781630 781620 781602 781430 781420 781402 781220 781202

37

37

30

30

81802SD 81804SD 81806SD 81808 81810 8208 81806 81804

81802

25

25

8-9071

15 3 4

911812SD 912002SD 912004SD 912202SD 912203 912204 912202 912004 912002

34

35

28 16 16 16 48 48 18 18 18

30

25

8-9106

35

34 34 34 34

9908DB 9912CA 9924 9923 9912

43

30

25

8-9106

30

25

8-9159

10 9 3 4

35

16

30

25

8-9170

30

30 30 30 30 30

25

8-9171

35

81812

25

25 17 20 20 22

8-9262

8-9470QS 8-9593 8-9590

8-9459

21

15

13 15 16 34 34

912204SD 912206SD 912208SD 912210SD 912212 932202 912210 912208 912206

34 35 34 35 34

LL195 LR195 9923 9924 LL240

9925

48

30

8208A 8211A

30

8208A 8213A

17

22

30

8214SC 82202GY 8216A

20

911202SD 911204SD 911402SD 911403SD 911404SD 911602SD 911603SD 911604SD 911802SD 911803SD 911804SD 911805 911806 911804 911803 911802 911604 911603 911602 911404 911403 911402 911204

911202

8-9996

8-9992

13

48

16 35

35

34 35 34

LL195 LR195 LL240

9925

48 48 18 18 18

30

30 30 30 30 7

82202SDGY 82204SDGY 8223SC 831202 8265A 82204GY

33

32 32 20 21 27 27 27

34

35 35 34 35 34 34 34 35

932202SD 932204SD 981202SD 981402SD 981404SD 981602SD 981604SD 981802SD 981804SD 981806 981808 981804 981802 981604 981602 981404 981402 981202 932204

35

34 34 26 26

30

33

35

30

26

7-9012

13 15 11 7 7 7 7

831202SD 831402SD 831602SD 831802SD 86202SD 86402SD 86602SD 86802SD 8-9006A 8-9062 8-9006A 86802 86602 86402 86202 831802 831602 831402

26 26 26 26 26 26 26 26 26 26 26

27

35

7-9012QS 7-9013 7-9112 8058C

7-9012

27 27 29 29

27

27

34 34 34 34

35

26

35

7-9112QS 8059PE 8062A 81202

20 21 9

29

35

29 29

35 35

81202SD 81402SD 81404SD 8158 81404 81402

25

25

25

29

25 17

25

25

29 4

34

29

911806SD 911808SD 911809 911808

34

981810

26

35 34

987202SD 987402SD 987602 987402

987202

26

28 28

13

13

35

28

34

28

28

62

Phone: (800) 343 2579 · Fax: (828) 389 3922 · www.adcable.com

Information

65 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

882858


You might also be interested in

BETA