SS-PRC018-EN

Split System Cooling Product & Performance Data

XB 10

TTB012-024 1, 1½ & 2 Tons

PUB. NO. 22-1689-05-0603 (EN)

General Features

Split System Cooling Units . . . Designed With Your Needs In Mind.

TTB Split systems represent a new approach to designing products for The Trane Company. The design team's mission is ". . . to bring a system to the marketplace that will meet your job requirements every time" . . . And at a competitive price. Trane's experienced design team used the newest computer technology and an entirely new manufacturing process to develop a new standard in split systems. Couple the Trane reputation for quality and reliability in split system air conditioners with improvements in efficiency, flexibility and installation ease . . . and you have systems that ® prove "It's Hard to Stop a Trane. " Manufacturing Control Trane's exclusive control over the design and manufacturing of all major components is unique in the industry. This approach assures us total control over both the quality and reliability of these components. It also allows us to custom match components to deliver the best in split system performance. Designing the Details Careful attention was given to designing the details -- from control wiring to the access panels. TTB units feature timesaving color coded wiring and removable panels which allow complete access to all major components and controls. All outdoor units feature external high and low pressure gauge port connections, and service valves for easy diagnosing and servicing of the unit are provided. Standardized Cabinets In addition all cabinets have been standardized; so when you are servicing an outdoor unit or an air handler all components are in the same location from unit to unit. UL Listed and ARI Certified Trane meets or exceeds all nationally recognized agency safety and design standards. Each unit is UL approved, and labeled in accordance to UL Standard 1995, including approval for use in Canada. Each unit is rated in accordance with ANSI ARI Standard 210/240 and 270.

© 2003 American Standard Inc. All Rights Reserved

2

22-1689-05-0603 (EN)

Contents

General Features Features and Benefits

Optional Equipment Low Outdoor Ambient Cooling A.R.I. Standard Capacity Rating Conditions

2 4

5 5 5

Selection Procedure

Model Number Nomenclature

6

6

General Data

TTB012C100A TTB018C100A TTB024C100A

7

7 9 11

Ratings with Auxiliary Devices Performance Data Cooling

TTB012C TTB018C TTB024C

13 14

14 15 17

Electrical Data Dimensions Mechanical Specification Options

19 20 21

22-1689-05-0603 (EN)

3

Features and Benefits

· Climatuff® compressor · All Aluminum Spine FinTM coil · Polyslate gray cabinet · Full coil protection · Corrosion resistant finish and fasteners · Internal high/low pressure & temperature protection · Liquid line filter-drier · Single-side service access · Multi-use liquid and suction line service valves · HCFC-22 refrigerant

· 5-year limited warranty on compressor, coil and 5 years on parts (Residential use) · Extended warranties available · S.E.E.T. design testing · 100% line run test · Low ambient cooling to 55°F. as shipped · Low ambient cooling to 40°F. with EDC accessory AY28X079 · Low ambient cooling to 30°F. with EDC accessory AY28X079 and TXV

4

22-1689-05-0603 (EN)

Features and Benefits

Optional Equipment

OPTIONAL EQUIPMENT FOR CONDENSING UNITS (Check mark [] indicates accessories included). Indoor Thermostats -- Electronic Setback ............................................................................................................ TAYSTAT300C [ Electronic, 1 Htg. (Gas)/1 Clg. (Non Prog.) .......................................................................... TAYSTAT370 [ Electronic, 1 Htg. (Elec.)/ 1 Clg. (Non Prog.)3 ..................................................................... TAYSTAT371[ Heating/Cooling -- Horizontal ................................................................................................. AY28X092 [ Cooling Only with Fan Switch .............................................................................................. BAYSTAT304 [ Heating/Cooling -- Vertical ................................................................................................. BAYSTAT305 [ Thermostat Locking Cover .................................................................................................... BAY28X190 [ Outdoor Thermostats 46°F. to -10°F. (Adjustable) (TTB018-024) .......................................................................... TAYSTAT250B [ Evaporator Defrost Control .......................................................................................................................................... AY28X079 [ Indoor Fan Delay Relay Kit ........................................................................................................................................ BAY24X045 [ Quick-Start Kit (TTB012-024C) .................................................................................................................................. BAY41X228 [ Isolators .................................................................................................................................................................... BAYISLT100 [ Outdoor Temperature Sensor .. (TAYSTAT300C) ................................................................................................. TAYSENS100A [

1 Not used with programmable thermostats 2 When field inner connecting lines exceed 60 linear ft. of length refer to the Application Guide (Pub. 22-3238-02)

] ] ] ] ] ] ] ] ] ] ] ] ]

BRAZED TUBING REFRIGERANT LINE SETS (All Suction Lines are Insulated.) 5/8" ODM (90° bend, one end), 5/8" & 1/4" tubing ................................................................................................ TAYREFLN1__* [ ] 3/4" ODM (90° bend, one end), 3/4" & 5/16" tubing .............................................................................................. TAYREFLN2__* [ ]

* Line lengths: 15, 20, 25, 30, 40 & 50 ft. Insert desired line length in catalog number at right for the complete number. Example: TAYREFLN220

Low Outdoor Ambient Cooling

Low Ambient Cooling FCCV AccutronTM Thermal Expansion Valve (TXV) As Manufactured 55°F 55°F Evaporator Defrost Control 40°F 30°F

A.R.I. Standard Capacity Rating Conditions

A.R.I. STANDARD 210/240 RATING CONDITIONS -- (A) Cooling 80°F. D.B., 67°F. W.B. air entering indoor coil, 95°F. D.B. air entering outdoor coil.

22-1689-05-0603 (EN)

5

Selection Procedure

Model Number Nomenclature 1 T 2 T 3 B 4 0 5 2 6 4 7 C 8 1 9 0 10 0 11 A

PRODUCT TYPE Split Cooling - TTA, TTB, TTN, TTR TTP, TTX, TTY, TTZ Split Heat Pump - TWA, TWN, TWP , TWR, TWX, TWY, TWZ Package Cooling TCC, TCH, TCD, TCX, TCM, TCP, TCY Package Heat Pump - WCC, WCD, WCH, WCZ, WCM, WCP, WCX, DCX, WCY Air Handler - TWE, TWG, TVF Gas/Electric - YCC, YCD, YCH, YCP, YCX, YCY, YCZ Coils - TXA, TXE, TXC, TXH, CCB, CUB SPLIT SYSTEM COUPLING SYSTEMS 1 - 5 TONS 0 - Brazed PRIMARY CAPACITY Example: 024 = 24 MBTUH = 2 Tons

MINOR DESIGN MODIFICATION SECONDARY FUNCTIONS Gas/Electric - Gas Heating Furnaces - Cooling Airflow Air Handlers - Flow Control POWER SUPPLY AND FUEL MAJOR DESIGN MODIFICATION

6

22-1689-05-0603 (EN)

General Data

OUTDOOR UNIT 12 SOUND RATING (DECIBELS) 2 POWER CONNS. -- V/PH/HZ 3 MIN. BRCH. CIR. AMPACITY BR. CIR. MAX. (AMPS) PROT. RTG. MIN. (AMPS) COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS 7 - L.R. AMPS START COMPONENTS 8 INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN -- TYPE DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. 4 NO. MOTORS - HP. MOTOR SPEED R.P .M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL -- TYPE ROWS - F .I. .P FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT (O.D. UNIT) NP CHRG. 5 FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS 6 LINE SIZE - IN. O.D. LIQ. 6 FCCV RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.)

TTB012C100A

}

TTB012C100A 82 200/230/1/60 11 15 15 CLIMATUFF® 1-1 200/230/1/60 8.0 - 45 NO NO YES PROPELLER 13.7 - 1 DIRECT - 1 1600 1 - 1/8 1650 200/230/1/60 0.83 SPINE FINTM 1 - 24 6.62 3/8 R-22 2/12-LB/OZ YES 5/8 1/4 0.049 H X W X D 24.75 X 20 X 20 SEE OUTLINE DWG. 118 112

1 CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. 4 STANDARD AIR - DRY COIL - OUTDOOR 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. 6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 32-3312-01. 7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. 8 NO MEANS NO START COMPONENTS YES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

CONDENSING UNIT WITH COOLING COILS

CCBA18A4AC FIXED ORIFICE 15800 10000 450 1.73 9.15/10.00 CUBA18A4AC FIXED ORIFICE 15800 10000 450 1.73 9.15/10.00 TXA018C4 FACT INS 49 14800 9700 525 1.61 9.20/10.00 TXA024C4 CHG TO 49 14400 9000 450 1.55 9.30/10.00 TXA025C4 CHG TO 49 14700 9500 450 1.56 9.40/10.05 TXC018C4 FACT INS 49 14800 9700 525 1.61 9.20/10.00 TXC024C4 CHG TO 49 14400 9000 450 1.55 9.30/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

TXC024D4 CHG TO 49 14400 9000 450 1.55 9.30/10.00

TXC025C4 CHG TO 49 14700 9500 450 1.56 9.40/10.05

TXC025D4 CHG TO 49 14700 9500 450 1.56 9.40/10.05

TXH025A4 CHG TO 49 16200 10200 450 1.74 9.30/10.00

CONDENSING UNIT WITH AIR HANDLERS

2TFB4018A1 FACT INS 49 16800 10900 450 1.78 9.45/10.00 2TFB4024A1 CHG TO 49 16700 10800 450 1.82 9.20/10.00 TVF018A14 FACT INS 49 15100 10000 450 1.56 9.65/10.50 TVF025A14 CHG TO 49 14900 9800 450 1.62 9.20/10.00 TWE018C14 FACT INS 49 14600 9300 450 1.56 9.35/10.20 TWE024C14 CHG TO 49 14400 9100 450 1.55 9.30/10.20 TWG018A14 FACT INS 49 14500 9300 450 1.56 9.30/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See

page 13 for combinations with Auxiliary Devices.

22-1689-05-0603 (EN)

7

General Data

TTB012C100A

CONDENSING UNIT WITH AIR HANDLERS

TWG025A14 CHG TO 49 14200 9100 450 1.49 9.55/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See page 13 for combinations with Auxiliary Devices.

8

22-1689-05-0603 (EN)

General Data

OUTDOOR UNIT 12 SOUND RATING (DECIBELS) 2 POWER CONNS. -- V/PH/HZ 3 MIN. BRCH. CIR. AMPACITY BR. CIR. MAX. (AMPS) PROT. RTG. MIN. (AMPS) COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS 7 - L.R. AMPS START COMPONENTS 8 INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN -- TYPE DIA.(IN) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. 4 NO. MOTORS - HP. MOTOR SPEED R.P .M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL -- TYPE ROWS - F .I. .P FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT (O.D. UNIT) NP CHRG. 5 FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS 6 LINE SIZE - IN. O.D. LIQ. 6 FCCV RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.)

TTB018C100A

}

TTB018C100A 82 200/230/1/60 11 15 15 CLIMATUFF® 1-1 200/230/1/60 8.0 - 45 NO NO YES PROPELLER 13.7 - 1 DIRECT - 1 1600 1 - 1/8 1650 200/230/1/60 0.83 SPINE FINTM 1 - 24 6.62 3/8 R-22 3/3-LB/OZ YES 5/8 1/4 0.049 H X W X D 24.75 X 20 X 20 SEE OUTLINE DWG. 118 112

1 CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. 4 STANDARD AIR - DRY COIL - OUTDOOR 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. 6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 32-3312-01. 7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. 8 NO MEANS NO START COMPONENTS YES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

CONDENSING UNIT WITH COOLING COILS

CCBA18A4AC FIXED ORIFICE 16600 11100 600 1.80 9.20/10.00 CCBA24A4AC FIXED ORIFICE 16600 11400 620 1.79 9.25/10.10 CUBA18A4AC FIXED ORIFICE 16600 11100 600 1.80 9.20/10.00 CUBA24A4AC FIXED ORIFICE 16600 11400 620 1.79 9.25/10.10 CUBB24A4AC FIXED ORIFICE 16600 11400 620 1.79 9.25/10.10 TXA018C4 FACT INS 49 17000 11400 600 1.82 9.35/10.00 TXA024C4 CHG TO 49 16800 11600 630 1.81 9.30/10.05

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

TXA025C4 CHG TO 49 17100 12700 640 1.83 9.35/10.00

TXC018C4 FACT INS 49 16600 11100 600 1.80 9.20/10.00

TXC024C4 CHG TO 49 16800 11600 630 1.81 9.30/10.05

TXC024D4 CHG TO 49 16800 11600 630 1.81 9.30/10.05

TXC025C4 CHG TO 49 17100 12700 640 1.83 9.35/10.00

TXC025D4 CHG TO 49 17100 12700 640 1.83 9.35/10.00

TXH025A4 CHG TO 49 17200 11900 640 1.85 9.30/10.00

CONDENSING UNIT WITH AIR HANDLERS

2TFB4018A1 FACT INS 49 17800 12500 600 1.84 9.70/10.00 2TFB4024A1 CHG TO 49 17900 13000 670 1.89 9.45/10.00 2TFB4030A1 CHG TO 49 17800 12800 665 1.95 9.15/10.00 TVF018A14 FACT INS 49 17300 12700 600 1.78 9.70/10.40 TVF024A14 CHG TO 49 17400 13300 650 1.86 9.35/10.15 TVF025A14 CHG TO 49 17500 13400 655 1.83 9.55/10.40 TWE018C14 FACT INS 49 17100 11600 600 1.77 9.65/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See

page 13 for combinations with Auxiliary Devices.

22-1689-05-0603 (EN)

9

General Data

TTB018C100A

CONDENSING UNIT WITH AIR HANDLERS

TWE024C14 CHG TO 49 16800 11600 625 1.79 9.40/10.00 TWG018A14 FACT INS 49 16500 11400 600 1.77 9.30/10.00 TWG025A14 CHG TO 49 16600 12100 620 1.74 9.55/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See

page 13 for combinations with Auxiliary Devices.

10

22-1689-05-0603 (EN)

General Data

OUTDOOR UNIT 12 SOUND RATING (DECIBELS) 2 POWER CONNS. -- V/PH/HZ 3 MIN. BRCH. CIR. AMPACITY BR. CIR. MAX. (AMPS) PROT. RTG. MIN. (AMPS) COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS 7 - L.R. AMPS START COMPONENTS 8 INSULATION/SOUND BLANKET COMPRESSOR HEAT OUTDOOR FAN -- TYPE DIA.(IN) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. 4 NO. MOTORS - HP. MOTOR SPEED R.P .M. VOLTS/PH/HZ F.L. AMPS OUTDOOR COIL -- TYPE ROWS - F .I. .P FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT (O.D. UNIT) NP CHRG. 5 FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS 6 LINE SIZE - IN. O.D. LIQ. 6 FCCV RESTRICTOR ORIFICE SIZE DIMENSIONS OUTDOOR UNIT CRATED (IN.) UNCRATED WEIGHT SHIPPING (LBS.) NET (LBS.)

TTB024C100A

}

TTB024C100A 80 208/230/1/60 15 25 20 CLIMATUFF® 1-1 200/230/1/60 11.6 - 60 NO NO YES PROPELLER 13.7 - 1 DIRECT - 1 1550 1 - 1/8 1650 200/230/1/60 0.83 SPINE FINTM 1 - 24 6.62 3/8 R-22 3/10-LB/OZ YES 3/4 5/16 0.057 H X W X D 24.75 X 20 X 20 SEE OUTLINE DWG. 130 125

1 CERTIFIED IN ACCORDANCE WITH THE UNITARY AIR-CONDITIONER EQUIPMENT CERTIFICATION PROGRAM WHICH IS BASED ON A.R.I. STANDARD 210/240. 2 RATED IN ACCORDANCE WITH A.R.I. STANDARD 270/SECTION 5.3.6. 3 CALCULATED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE. ONLY USE HACR CIRCUIT BREAKERS OR FUSES. 4 STANDARD AIR - DRY COIL - OUTDOOR 5 THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNIT NAMEPLATE AND SERVICE INSTRUCTION. 6 MAX. LINEAR LENGTH: 80 FT WITH RECIPROCATING COMPRESSOR 60 FT WITH SCROLL. MAX. LIFT - SUCTION 60 FT; MAX LIFT - LIQUID 60 FT. FOR GREATER LENGTH REFER TO REFRIGERANT PIPING SOFTWARE PUB. NO. 32-3312-01. 7 THE VALUE SHOWN FOR COMPRESSOR RLA ON THE UNIT NAMEPLATE AND ON THIS SPECIFICATION SHEET IS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITY AND MAXIMUM FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUIT SELECTION CURRENT. 8 NO MEANS NO START COMPONENTS YES MEANS QUICK START KIT COMPONENTS PTC MEANS POSITIVE TEMPERATURE COEFFICIENT STARTER.

SPLIT SYSTEM

CONDENSING UNIT WITH COOLING COILS

CCBA24A4AC FIXED ORIFICE 22000 14900 800 2.40 9.15/10.00 CCBA30A4AC FIXED ORIFICE 21200 14500 775 2.36 9.00/10.00 CCBB30A4AC FIXED ORIFICE 22000 16200 800 2.39 9.20/10.00 CUBA24A4AC FIXED ORIFICE 22000 14900 800 2.40 9.15/10.00 CUBA30A4AC FIXED ORIFICE 21200 14500 775 2.36 9.00/10.00 CUBB24A4AC FIXED ORIFICE 22000 14900 800 2.40 9.15/10.00 CUBB30A4AC FIXED ORIFICE 22000 16200 800 2.39 9.20/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

TXA024C4 FACT INS 57 22200 15000 800 2.44 9.10/10.00

TXA025C4 FACT INS 57 21800 15500 800 2.37 9.20/10.00

TXA030C4 CHG TO 57 22200 15400 825 2.40 9.25/10.00

TXA031C4 CHG TO 57 22400 16400 835 2.41 9.30/10.00

TXA035C4 CHG TO 57 22000 15100 825 2.37 9.30/10.00

TXA036C4 CHG TO 57 22800 16800 850 2.43 9.40/10.00

TXC024C4 FACT INS 57 21400 14500 800 2.34 9.15/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See

TXC024D4 FACT INS 57 21400 14500 800 2.34 9.15/10.00

TXC025C4 FACT INS 57 21800 15500 800 2.37 9.20/10.00

TXC025D4 FACT INS 57 21800 15500 800 2.37 9.20/10.00

TXC030C4 CHG TO 57 22200 15400 825 2.40 9.25/10.00

TXC030D4 CHG TO 57 22200 15400 825 2.40 9.25/10.00

TXC031C4 CHG TO 57 22400 16400 835 2.41 9.30/10.00

TXC031D4 CHG TO 57 22400 16400 835 2.41 9.30/10.00

page 13 for combinations with Auxiliary Devices.

22-1689-05-0603 (EN)

11

General Data

TTB024C100A

CONDENSING UNIT WITH COOLING COILS

TXC035C4 CHG TO 57 22000 15100 825 2.37 9.30/10.00 TXC035D4 CHG TO 57 22000 15100 825 2.37 9.30/10.00 TXC036C4 CHG TO 57 22800 16800 850 2.43 9.40/10.00 TXC036D4 CHG TO 57 22800 16800 850 2.43 9.40/10.00 TXC037C4 CHG TO 57 22800 16800 850 2.43 9.40/10.00 TXH025A4 FACT INS 57 21400 14500 800 2.33 9.20/10.00 TXH033A4 FACT INS 57 22400 16400 840 2.38 9.40/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

CONDENSING UNIT WITH AIR HANDLERS

2TFB4018A1 CHG TO 57 21800 14600 675 2.29 9.50/10.00 2TFB4024A1 FACT INS 57 22200 15500 800 2.39 9.30/10.00 2TFB4030A1 CHG TO 57 22200 15800 825 2.44 9.10/10.00 TVF018A14 CHG TO 57 21600 15000 675 2.34 9.25/10.20 TVF024A14 CHG TO 57 22200 16300 800 2.40 9.25/10.20 TVF025A14 CHG TO 57 22400 16500 800 2.38 9.40/10.40 TVF030A14 CHG TO 57 23000 17700 850 2.43 9.45/10.40

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

TVF036A14 CHG TO 57 23000 17600 860 2.50 9.20/10.10

TWE018C14 CHG TO 57 20800 13600 675 2.26 9.20/10.00

TWE024C14 CHG TO 57 21000 14300 775 2.30 9.15/10.00

TWE030C14 CHG TO 57 21800 15700 810 2.38 9.15/10.05

TWE036C14 CHG TO 57 22600 16300 835 2.44 9.25/10.15

TWG018A14 CHG TO 57 20400 13600 675 2.24 9.10/10.00

TWG025A14 CHG TO 57 21000 14700 785 2.23 9.40/10.00

EXPANSION TYPE RATINGS (COOLING) 1 BTUH (TOTAL) BTUH (SENSIBLE) INDOOR AIRFLOW (CFM) SYSTEM POWER (KW) EER/SEER (BTU/WATT-HR.)

See

TWG030A14 CHG TO 57 21800 15400 815 2.36 9.25/10.00

page 13 for combinations with Auxiliary Devices.

12

22-1689-05-0603 (EN)

Ratings with Auxiliary Devices

COMBINATIONS WITH FAN DELAY RELAY KIT AND/OR TXV KIT

When models are matched with an indoor air handler or coil that has a flow control check valve or expansion valve flow control, the addition of an indoor fan delay relay and/or TXV kit may increase the system SEER. See charts below for ratings.

OUTDOOR MODEL INDOOR MODEL FAN DELAY KIT TXV KIT COOLING CAPACITY OUTDOOR MODEL INDOOR MODEL FAN DELAY KIT TXV KIT COOLING CAPACITY

CFM

SEER

CFM

SEER

TTB012C100A TTB012C100A * TTB012C100A TTB012C100A * TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB012C100A TTB018C100A TTB018C100A * TTB018C100A TTB018C100A * TTB018C100A TTB018C100A * TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A TTB018C100A

2TFB4018A1 2TFB4018A1 2TFB4024A1 2TFB4024A1 CCBA18A4AC CUBA18A4AC TXA018C4 TXA024C4 TXA025C4 TXC018C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4 TXH025A4 2TFB4018A1 2TFB4018A1 2TFB4024A1 2TFB4024A1 2TFB4030A1 2TFB4030A1 CCBA18A4AC CCBA24A4AC CUBA18A4AC CUBA24A4AC CUBB24A4AC TXA018C4 TXA024C4 TXA025C4 TXC018C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4 TXH025A4

FI FI FI FI Y Y Y Y Y Y Y Y Y Y Y FI FI FI FI FI FI Y Y Y Y Y Y Y Y Y Y Y Y Y Y

NB NB NB NB NO NO NO NO NO NO NO NO NO NO NO NB NB NB NB NB NB NO NO NO NO NO NO NO NO NO NO NO NO NO NO

450 450 450 450 450 450 535 450 450 535 450 450 450 450 450 600 600 650 650 650 650 600 620 600 620 620 600 630 640 600 630 630 640 640 640

10.50 10.50 10.25 10.25 10.15 10.15 10.25 10.25 10.35 10.25 10.25 10.25 10.35 10.35 10.30 10.75 10.75 10.50 10.50 10.25 10.25 10.20 10.40 10.20 10.40 10.40 10.30 10.30 10.35 10.30 10.30 10.30 10.35 10.35 10.30

16600 16600 16400 16400 15800 15800 14800 14400 14700 14800 14400 14400 14700 14700 16200 17500 17500 17600 17600 17500 17500 16600 16600 16600 16600 16600 17000 16800 17100 17000 16800 16800 17100 17100 17200

TTB024C100A TTB024C100A * TTB024C100A TTB024C100A * TTB024C100A TTB024C100A * TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A TTB024C100A

2TFB4018A1 2TFB4018A1 2TFB4024A1 2TFB4024A1 2TFB4030A1 2TFB4030A1 CCBA24A4AC CCBA30A4AC CCBB30A4AC CUBA24A4AC CUBA30A4AC CUBB24A4AC CUBB30A4AC TXA018C4 TXA024C4 TXA025C4 TXA030C4 TXA031C4 TXA035C4 TXA036C4 TXA037C4 TXC018C4 TXC024C4 TXC024D4 TXC025C4 TXC025D4 TXC030C4 TXC030D4 TXC031C4 TXC031D4 TXC035C4 TXC035D4 TXC036C4 TXC036D4 TXC037C4 TXH025A4 TXH033A4

FI FI FI FI FI FI Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y

NB NB NB NB NB NB NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO

675 675 800 800 815 815 800 775 800 800 775 800 800 675 800 800 825 835 825 850 850 675 800 800 800 800 825 825 835 835 825 825 850 850 850 800 840

10.50 10.50 10.25 10.25 10.00 10.00 10.10 10.10 10.20 10.10 10.10 10.10 10.20 10.05 10.10 10.25 10.30 10.30 10.30 10.40 10.40 10.05 10.10 10.10 10.25 10.25 10.30 10.30 10.30 10.30 10.30 10.30 10.40 10.40 10.40 10.20 10.40

21600 21600 22000 22000 21800 21800 22000 21200 22000 22000 21200 22000 22000 20400 22200 21800 22200 22400 22000 22800 22800 20400 22200 22200 21800 21800 22200 22200 22400 22400 22000 22000 22800 22800 22800 21400 22400

FI - FACTORY INSTALLED

B - BLEED TXV

NB - NON-BLEED TXV

* - START KIT REQUIRED

22-1689-05-0603 (EN)

13

Performance Data Cooling

TTB012C WITH TXC018C4 AT 550 CFM

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOT. CAP. 13.1 14.3 15.5 16.7 12.8 13.8 14.9 16.0 12.2 13.2 14.1 15.2 11.6 12.5 13.4 14.3 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 10.0 11.3 12.6 13.3* 8.4 9.7 11.0 11.8 6.6 7.9 9.2 10.0 4.8 6.0 7.3 8.2 9.9 8.2 6.4 4.6 9.6 8.0 6.2 4.3 9.4 7.7 5.9 4.0 11.1 9.5 7.7 5.8 10.9 9.3 7.4 5.5 10.6 9.0 7.2 5.3 12.4 10.8 9.0 7.1 12.2 10.5 8.7 6.8 11.7* 10.3 8.4 6.5 13.0* 11.6 9.8 7.9 12.5* 11.4 9.5 7.6 12.0* 11.1 9.2 7.4 TOTAL KW 1.46 1.49 1.52 1.54 1.57 1.60 1.62 1.65 1.70 1.72 1.74 1.76 1.82 1.84 1.86 1.88

TTB012C

95

105

115

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH 450 600 0.96 1.01 0.91 1.04

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES. * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW 2TFB4018A1 RATED 450 1.11 1.10 1.09 LOW 400 1.08 1.05 1.10 HIGH 500 1.13 1.16 1.08 2TFB4024A1 RATED 450 1.10 1.09 1.11 LOW 400 1.07 1.04 1.12 HIGH 500 1.12 1.15 1.10 CCBA18A4AC RATED 450 1.06 1.02 1.06 LOW 400 1.04 0.97 1.07 HIGH 500 1.08 1.07 1.05 CCBA18A4AC+BAY24X045 RATED 450 1.06 1.02 1.06 LOW 400 1.04 0.97 1.07 HIGH 500 1.08 1.07 1.05 CUBA18A4AC RATED 450 1.06 1.02 1.06 LOW 400 1.04 0.97 1.07 HIGH 500 1.08 1.07 1.05 CUBA18A4AC+BAY24X045 RATED 450 1.06 1.02 1.06 LOW 400 1.04 0.97 1.07 HIGH 500 1.08 1.07 1.05 TVF018A14 RATED 450 1.01 1.03 0.96 LOW 400 0.99 0.96 0.97 HIGH 500 1.03 1.09 0.95 TVF025A14 RATED 450 1.00 1.01 1.00 LOW 400 0.98 0.95 1.01 HIGH 500 1.02 1.06 0.99 TWE018C14 RATED 450 0.98 0.95 0.96 LOW 400 0.96 0.90 0.97 HIGH 500 1.00 1.00 0.95 TWE024C14 RATED 450 0.97 0.94 0.95 LOW 400 0.94 0.89 0.96 HIGH 500 0.99 0.99 0.94 TWG018A14 RATED 450 0.97 0.96 0.96 LOW 400 0.96 0.91 0.97 HIGH 500 0.99 1.01 0.95

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW TWG025A14 RATED 450 0.95 0.95 0.92 LOW 400 0.94 0.89 0.92 HIGH 500 0.97 1.00 0.91 TXA018C4 RATED 550 1.00 1.00 1.00 LOW 450 0.97 0.91 1.01 HIGH 600 1.01 1.04 0.98 TXA018C4+BAY24X045 RATED 550 1.00 0.94 1.00 LOW 475 0.98 0.89 1.01 HIGH 600 1.01 0.98 0.99 TXA024C4 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXA024C4+BAY24X045 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXA025C4 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXA025C4+BAY24X045 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXC018C4 RATED 550 1.00 1.00 1.00 LOW 450 0.96 0.91 1.01 HIGH 600 1.01 1.04 0.98 TXC018C4+BAY24X045 RATED 550 1.00 0.94 1.00 LOW 475 0.98 0.89 1.01 HIGH 600 1.01 0.98 0.99 TXC024C4 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXC024C4+BAY24X045 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXC024D4 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXC024D4+BAY24X045 RATED 450 0.97 0.94 0.95 LOW 400 0.95 0.89 0.96 HIGH 500 0.99 0.99 0.94 TXC025C4 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXC025C4+BAY24X045 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXC025D4 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXC025D4+BAY24X045 RATED 450 0.99 0.99 0.96 LOW 400 0.97 0.93 0.97 HIGH 500 1.01 1.03 0.95 TXH025A4 RATED 450 1.09 1.05 1.07 LOW 400 1.07 1.00 1.08 HIGH 500 1.11 1.10 1.06 TXH025A4+BAY24X045 RATED 450 1.09 1.05 1.07 LOW 400 1.07 1.00 1.08 HIGH 500 1.11 1.10 1.06

14

22-1689-05-0603 (EN)

Performance Data Cooling

TTB018C WITH TXC018C4 AT 600 CFM

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOT. CAP. 14.7 15.9 17.2 18.6 14.1 15.3 16.6 17.9 13.4 14.5 15.7 16.9 12.6 13.7 14.8 16.0 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 11.4 12.8 14.2 14.9* 9.6 11.0 12.4 13.3 7.6 9.0 10.4 11.3 5.5 7.0 8.3 9.3 11.2 9.4 7.4 5.3 10.8 9.0 7.0 5.0 10.5 8.7 6.7 4.6 12.6 10.8 8.8 6.7 12.3 10.4 8.4 6.3 11.9 10.1 8.1 6.0 14.0 12.2 10.2 8.1 13.5* 11.8 9.8 7.8 12.9* 11.5 9.5 7.4 14.5* 13.1 11.1 9.0 13.9* 12.8 10.8 8.7 13.2* 12.5 10.4 8.4 TOTAL KW 1.62 1.65 1.68 1.72 1.74 1.77 1.80 1.84 1.88 1.91 1.94 1.97 2.02 2.04 2.07 2.10

TTB018C

95

105

115

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH 525 675 0.98 1.02 0.94 1.05

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES. * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW 2TFB4018A1 RATED 600 1.06 1.11 1.01 LOW 525 1.04 1.04 1.02 HIGH 675 1.08 1.17 1.00 2TFB4024A1 RATED 700 1.07 1.17 1.05 LOW 600 1.05 1.08 1.06 HIGH 800 1.08 1.24 1.03 2TFB4030A1 RATED 700 1.06 1.16 1.07 LOW 600 1.04 1.08 1.09 HIGH 800 1.07 1.23 1.06 CCBA18A4AC RATED 600 1.00 1.00 1.00 LOW 525 0.98 0.94 1.01 HIGH 675 1.01 1.05 0.99 CCBA18A4AC+BAY24X045 RATED 600 1.00 1.00 1.00 LOW 525 0.98 0.94 1.01 HIGH 675 1.01 1.05 0.99 CCBA24A4AC RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99 CCBA24A4AC+BAY24X045 RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99 CUBA18A4AC RATED 600 1.00 1.00 1.00 LOW 525 0.98 0.94 1.01 HIGH 675 1.01 1.05 0.99 CUBA18A4AC+BAY24X045 RATED 600 1.00 1.00 1.00 LOW 525 0.98 0.94 1.01 HIGH 675 1.01 1.05 0.99 CUBA24A4AC RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99 CUBA24A4AC+BAY24X045 RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW CUBB24A4AC RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99 CUBB24A4AC+BAY24X045 RATED 600 0.99 1.02 0.99 LOW 550 0.98 0.98 1.00 HIGH 700 1.01 1.09 0.99 TVF018A14 RATED 600 1.04 1.13 0.99 LOW 525 1.02 1.06 1.00 HIGH 675 1.05 1.19 0.98 TVF024A14 RATED 700 1.05 1.20 1.04 LOW 575 1.03 1.09 1.04 HIGH 750 1.06 1.25 1.03 TVF025A14 RATED 700 1.06 1.21 1.02 LOW 575 1.04 1.10 1.02 HIGH 750 1.07 1.26 1.01 TWE018C14 RATED 600 1.03 1.05 0.98 LOW 525 1.01 0.98 0.99 HIGH 675 1.05 1.11 0.97 TWE024C14 RATED 600 1.01 1.03 0.98 LOW 550 1.00 0.99 0.99 HIGH 700 1.03 1.10 0.97 TWG018A14 RATED 600 1.00 1.03 0.98 LOW 525 0.98 0.97 0.99 HIGH 675 1.01 1.08 0.97 TWG025A14 RATED 600 1.00 1.06 0.96 LOW 550 0.99 1.02 0.97 HIGH 700 1.02 1.14 0.95 TXA018C4 RATED 600 1.03 1.03 1.01 LOW 525 1.01 0.96 1.02 HIGH 675 1.04 1.08 1.00 TXA018C4+BAY24X045 RATED 600 1.03 1.02 1.01 LOW 525 1.01 0.97 1.02 HIGH 675 1.05 1.08 1.00 TXA024C4 RATED 600 1.01 1.02 0.99 LOW 550 1.00 0.98 1.00 HIGH 725 1.03 1.12 0.98 TXA024C4+BAY24X045 RATED 600 1.00 1.02 0.99 LOW 550 0.99 0.98 1.00 HIGH 725 1.02 1.11 0.98 TXA025C4 RATED 600 1.02 1.10 1.00 LOW 550 1.01 1.05 1.01 HIGH 725 1.04 1.20 0.99 TXA025C4+BAY24X045 RATED 700 1.04 1.17 1.03 LOW 575 1.02 1.06 1.03 HIGH 725 1.04 1.19 1.02 TXC018C4 RATED 600 1.00 1.00 1.00 LOW 525 0.98 0.94 1.01 HIGH 675 1.02 1.05 0.99 TXC018C4+BAY24X045 RATED 600 1.02 1.02 1.01 LOW 525 1.00 0.97 1.02 HIGH 675 1.03 1.08 1.00 TXC024C4 RATED 600 1.01 1.02 0.99 LOW 550 1.00 0.98 1.00 HIGH 725 1.03 1.12 0.98 TXC024C4+BAY24X045 RATED 600 1.00 1.02 0.99 LOW 550 0.99 0.98 1.00 HIGH 725 1.02 1.11 0.98 TXC024D4 RATED 600 1.01 1.02 0.99 LOW 550 1.00 0.98 1.00 HIGH 725 1.03 1.12 0.98 TXC024D4+BAY24X045 RATED 600 1.00 1.02 0.99 LOW 550 0.99 0.98 1.00 HIGH 725 1.02 1.11 0.98

22-1689-05-0603 (EN)

15

Performance Data Cooling

TTB018C

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW TXC025C4 RATED 600 1.02 1.10 1.00 LOW 550 1.01 1.05 1.01 HIGH 725 1.04 1.20 0.99 TXC025C4+BAY24X045 RATED 700 1.04 1.17 1.03 LOW 575 1.02 1.06 1.03 HIGH 725 1.04 1.19 1.02 TXC025D4 RATED 600 1.02 1.10 1.00 LOW 550 1.01 1.05 1.01 HIGH 725 1.04 1.20 0.99

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW TXC025D4+BAY24X045 RATED 700 1.04 1.17 1.03 LOW 575 1.02 1.06 1.03 HIGH 725 1.04 1.19 1.02 TXH025A4 RATED 600 1.03 1.04 1.01 LOW 550 1.02 1.00 1.02 HIGH 725 1.05 1.14 1.00 TXH025A4+BAY24X045 RATED 600 1.03 1.04 1.01 LOW 550 1.02 1.00 1.02 HIGH 725 1.05 1.14 1.00

16

22-1689-05-0603 (EN)

Performance Data Cooling

TTB024C WITH TXC024C4 AT 800 CFM

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOT. CAP. 19.1 20.7 22.4 24.1 18.3 19.8 21.4 23.1 17.2 18.6 20.1 21.7 16.1 17.5 18.9 20.3 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 14.9 16.8 18.6 19.5* 12.6 14.4 16.3 17.5 9.9 11.8 13.6 14.8 7.2 9.0 10.9 12.1 14.6 12.2 9.5 6.8 14.1 11.7 9.1 6.3 13.7 11.3 8.6 5.9 16.5 14.1 11.4 8.7 16.0 13.6 10.9 8.2 15.6 13.2 10.4 7.7 18.3* 15.9 13.2 10.5 17.5* 15.5 12.8 10.0 16.6* 15.0 12.3 9.6 18.8* 17.2 14.5 11.8 17.9* 16.7 14.0 11.3 17.0* 16.2 13.6 10.8 TOTAL KW 2.09 2.14 2.20 2.26 2.22 2.28 2.34 2.40 2.36 2.42 2.49 2.55 2.51 2.57 2.63 2.70

TTB024C

95

105

115

CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW TOTAL CAPACITY SENSIBLE CAPACITY LOW HIGH 700 900 0.98 1.01 0.94 1.05

NOTE: ALL TABLES ABOVE ARE AT ARI RATING CONDITIONS RATED WITH 25 FEET OF REFRIGERANT LINES. * DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY) TOTAL CAPACITY, COMP. KW AND APP. DEW PT. ARE VALID ONLY FOR WET COIL. ALL TEMPERATURES IN DEGREES F.

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW 2TFB4018A1 RATED 700 1.01 1.02 0.98 LOW 600 0.98 0.94 0.99 HIGH 800 1.03 1.08 0.97 2TFB4024A1 RATED 800 1.02 1.06 1.02 LOW 700 1.00 0.99 1.03 HIGH 900 1.04 1.11 1.01 2TFB4030A1 RATED 900 1.02 1.11 1.05 LOW 775 1.00 1.03 1.06 HIGH 1025 1.03 1.17 1.04 CCBA24A4AC RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02 CCBA24A4AC+BAY24X045 RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02 CCBA30A4AC RATED 800 0.99 1.01 1.02 LOW 675 0.97 0.94 1.03 HIGH 875 1.00 1.05 1.01 CCBA30A4AC+BAY24X045 RATED 800 0.99 1.01 1.01 LOW 675 0.97 0.94 1.03 HIGH 875 1.00 1.05 1.00 CCBB30A4AC RATED 800 1.03 1.11 1.02 LOW 700 1.01 1.04 1.03 HIGH 900 1.04 1.17 1.01 CCBB30A4AC+BAY24X045 RATED 800 1.03 1.11 1.02 LOW 700 1.01 1.04 1.03 HIGH 900 1.04 1.17 1.01 CUBA24A4AC RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02 CUBA24A4AC+BAY24X045 RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW CUBA30A4AC RATED 800 0.99 1.01 1.02 LOW 675 0.97 0.94 1.03 HIGH 875 1.00 1.05 1.01 CUBA30A4AC+BAY24X045 RATED 800 0.99 1.01 1.01 LOW 675 0.97 0.94 1.03 HIGH 875 1.00 1.05 1.00 CUBB24A4AC RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02 CUBB24A4AC+BAY24X045 RATED 800 1.03 1.03 1.03 LOW 700 1.01 0.98 1.04 HIGH 900 1.04 1.08 1.02 CUBB30A4AC RATED 800 1.03 1.11 1.02 LOW 700 1.01 1.04 1.03 HIGH 900 1.04 1.17 1.01 CUBB30A4AC+BAY24X045 RATED 800 1.03 1.11 1.02 LOW 700 1.01 1.04 1.03 HIGH 900 1.04 1.17 1.01 TVF018A14 RATED 700 1.02 1.04 1.01 LOW 600 1.00 0.97 1.02 HIGH 750 1.03 1.08 1.00 TVF024A14 RATED 800 1.04 1.11 1.03 LOW 700 1.02 1.04 1.04 HIGH 900 1.05 1.18 1.02 TVF025A14 RATED 800 1.05 1.12 1.02 LOW 700 1.03 1.05 1.03 HIGH 900 1.06 1.19 1.01 TVF030A14 RATED 900 1.08 1.22 1.05 LOW 750 1.06 1.11 1.05 HIGH 950 1.09 1.26 1.04 TVF036A14 RATED 900 1.08 1.21 1.08 LOW 750 1.06 1.10 1.09 HIGH 975 1.09 1.26 1.06 TWE018C14 RATED 700 0.98 0.95 0.97 LOW 600 0.95 0.89 0.98 HIGH 750 0.99 0.98 0.96 TWE024C14 RATED 800 0.99 1.00 0.99 LOW 675 0.96 0.93 1.00 HIGH 875 1.00 1.04 0.98 TWE030C14 RATED 800 1.02 1.07 1.02 LOW 700 1.00 1.01 1.03 HIGH 900 1.03 1.13 1.01 TWE036C14 RATED 800 1.05 1.10 1.04 LOW 725 1.04 1.06 1.05 HIGH 950 1.07 1.19 1.03 TWG018A14 RATED 700 0.96 0.96 0.97 LOW 600 0.94 0.90 0.98 HIGH 750 0.97 0.98 0.96 TWG025A14 RATED 800 0.98 1.02 0.96 LOW 700 0.96 0.96 0.97 HIGH 900 0.99 1.07 0.95 TWG030A14 RATED 800 1.02 1.05 1.01 LOW 725 1.01 1.01 1.02 HIGH 925 1.04 1.13 1.00 TXA018C4+BAY24X045 RATED 700 0.96 0.92 0.98 LOW 600 0.93 0.87 0.99 HIGH 750 0.97 0.95 0.97 TXA024C4 RATED 800 1.04 1.04 1.04 LOW 700 1.02 0.99 1.05 HIGH 900 1.05 1.09 1.03 TXA024C4+BAY24X045 RATED 800 1.04 1.04 1.04 LOW 700 1.02 0.99 1.05 HIGH 900 1.05 1.09 1.03

22-1689-05-0603 (EN)

17

Performance Data Cooling

TTB024C

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW TXA025C4 RATED 800 1.02 1.06 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXA025C4+BAY24X045 RATED 800 1.02 1.06 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXA030C4 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 TXA030C4+BAY24X045 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 TXA031C4 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.05 1.03 HIGH 950 1.06 1.19 1.01 TXA031C4+BAY24X045 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.05 1.03 HIGH 950 1.06 1.19 1.01 TXA035C4 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXA035C4+BAY24X045 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXA036C4 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXA036C4+BAY24X045 RATED 900 1.07 1.18 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXA037C4 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXA037C4+BAY24X045 RATED 900 1.07 1.18 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.09 1.21 1.04 TXC018C4+BAY24X045 RATED 700 0.96 0.92 0.98 LOW 600 0.93 0.87 0.99 HIGH 750 0.97 0.95 0.97 TXC024C4 RATED 800 1.00 1.00 1.00 LOW 700 0.98 0.94 1.01 HIGH 900 1.01 1.05 0.99 TXC024C4+BAY24X045 RATED 800 1.04 1.04 1.04 LOW 700 1.02 0.99 1.05 HIGH 900 1.05 1.09 1.03 TXC024D4 RATED 800 1.00 1.00 1.00 LOW 700 0.98 0.94 1.01 HIGH 900 1.01 1.05 0.99 TXC024D4+BAY24X045 RATED 800 1.04 1.04 1.04 LOW 700 1.02 0.99 1.05 HIGH 900 1.05 1.09 1.03 TXC025C4 RATED 800 1.02 1.06 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXC025C4+BAY24X045 RATED 800 1.02 1.07 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXC025D4 RATED 800 1.02 1.06 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXC025D4+BAY24X045 RATED 800 1.02 1.07 1.01 LOW 700 1.00 1.00 1.02 HIGH 900 1.03 1.13 1.00 TXC030C4 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 18

CORRECTION FACTORS FOR OTHER COMBINATIONS (MULTIPLY DATA BY FACTOR) MBTUH MBTUH SYST INDOOR MODEL CFM TOT SEN KW TXC030C4+BAY24X045 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 TXC030D4 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 TXC030D4+BAY24X045 RATED 800 1.04 1.05 1.02 LOW 725 1.03 1.01 1.03 HIGH 925 1.06 1.13 1.01 TXC031C4 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.05 1.03 HIGH 950 1.06 1.19 1.01 TXC031C4+BAY24X045 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.06 1.03 HIGH 950 1.07 1.19 1.01 TXC031D4 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.05 1.03 HIGH 950 1.06 1.19 1.01 TXC031D4+BAY24X045 RATED 800 1.04 1.10 1.02 LOW 725 1.03 1.06 1.03 HIGH 950 1.07 1.19 1.01 TXC035C4 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXC035C4+BAY24X045 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXC035D4 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXC035D4+BAY24X045 RATED 800 1.03 1.04 1.01 LOW 725 1.02 1.00 1.02 HIGH 925 1.05 1.11 1.00 TXC036C4 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXC036C4+BAY24X045 RATED 900 1.07 1.18 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXC036D4 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXC036D4+BAY24X045 RATED 900 1.07 1.18 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXC037C4 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXC037C4+BAY24X045 RATED 900 1.07 1.17 1.05 LOW 750 1.05 1.08 1.05 HIGH 950 1.08 1.21 1.04 TXH025A4 RATED 800 1.00 1.00 1.00 LOW 700 0.98 0.94 1.01 HIGH 900 1.01 1.05 0.99 TXH025A4+BAY24X045 RATED 800 1.00 1.00 1.00 LOW 700 0.98 0.94 1.01 HIGH 900 1.01 1.05 0.99 TXH033A4 RATED 800 1.04 1.10 1.01 LOW 725 1.03 1.05 1.02 HIGH 950 1.06 1.18 1.00 TXH033A4+BAY24X045 RATED 800 1.04 1.10 1.01 LOW 725 1.03 1.05 1.02 HIGH 950 1.06 1.18 1.00

22-1689-05-0603 (EN)

Electrical Data

SCHEMATIC DIAGRAMS TTB012-024C LEGEND

SYMBOL

From Dwg. 21C149013 P03 22-1689-05-0603 (EN) 19

Dimensions

TTB012-024 OUTLINE DRAWING

NOTE: ALL DIMENSIONS ARE IN MM (INCHES)

MODEL TTB012C TTB018C TTB024C

A 5/8 5/8 3/4

B 1/4 1/4 5/16

NOTE: TABLE IN INCHES ONLY.

From Dwg. 21D147830 Rev. 2 20 22-1689-05-0603 (EN)

Mechanical Specification Options

General This unit is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit is UL listed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff® compressor features a 5-year limited warranty, internal over temperature and pressure protection, total dipped hermetic motor windings. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise.

Condenser Coil The Spine FinTM coil is continuously wrapped, corrosion resistant aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum glued to a continuous aluminum fin. The coil is protected on all four sides by louvered panels and has a 5-year limited warranty. Low Ambient Cooling As shipped, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. Accessories Thermostats ­ Cooling only and heat/ cooling (manual and automatic changeover). Sub-base to match thermostat and locking thermostat cover. Quick Start Kit ­ Required for system with reciprocating compressors when applied with indoor coils with non-bleed expansion devices. Low voltage operation: to 180 V. for systems with reciprocating compressors; to 187 V. for systems with scroll compressors. Evaporator Defrost Control ­ See Low Ambient Cooling.

22-1689-05-0603 (EN)

21

Notes

22

22-1689-05-0603 (EN)

Notes

22-1689-05-0603 (EN)

23

Literature Order Number Order Number File Number Number Supersedes Stocking Location

SS-PRC007-EN SS-PRC018-EN -- PL-UN-SS-PRC018-EN 06/03 SS-PRC007-EN TTB-D-7 12/00 2/02 PI Louisville & Webb/Mason Houston Webb/Mason-Houston

P.I.

Trane A business of American Standard Companies www.trane.com

Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

Information