Read alces_foundation_details_01.pdf text version

TIMBER POST 6-1/2" INSULATED PANEL 5/8" GAP SUB FLOOR

PROVED SOLID BLOCKING DIRECTLY UNDER TIMBER POSTS TO RECEIVE TENNON

BEARING STUDWALL

5/8"Ø ANCHOR BOLTS

@ 6' MAX. TYP. TERMITE SHIELD ENTIRE PERIMETER DOUBLE 2X12 P.T. SILL ON SILL SEALER

Design and construction of traditionally joined timber frame structures

3-1/2" DIA STL COLUMN W/ 4-1/2" SQUARE 1/4" THICK PLATE WELDED ON EACH END; SHOP PRIME OR FIELD PRIME W/ RED OXIDE PAINT OR EQUAL; (2) 1/2" BOLTS TO FOOTING

I.C.F. 3" HEIGHT ADJUSTERS

PARGING MATERIAL TO SKIRT 1" TO 1/2" OVER W.P. MEMBRANE

4-# 4 BARS 2'-0" O.C.

SEE TYP. WALL DETAIL

2-# 4 BARS

3'-0" X 3'-0" X 8" FOOTING SIZE CAN BE REDUCED IF BEARING ON LEDGE 3-# 4 BARS

2'-0"

FOOTING

WATERPROOF MEMBRANE TO GRADE LINE

EXPANSION JOINT AND FILLER

MIN. 4" REINFORCED HEATED CEM. CONC. SLAB

HEAT TUBES

WELDED WIRE MESH

03 FD

POST AND FOOTING DETAIL SCALE 3/4"= 1'

04 FD

THICKENED SLAB SCALE 3/4"= 1'

8'-3"

2" POLYSTYRENE INSULATION

6 MIL. POLY VAPOR BARRIER

Crushed gravel back fill

3/4" CRUSHED WASHED STONE MIN. 6" DEEP

REBAR AS REQUIRED

I.C.F. 8" CORE

EXPANSION JOINT AND FILLER

MIN. 4" REINFORCED CEM. CONC. SLAB

WALL LINE

SLOPE SLAB NO ANCHOR BOLTS

4"

8"

HEAT TUBES

WELDED WIRE MESH

COVER DRAIN PIPE WITH MIN. 12" OF CRUSHED STONE

8"

2" POLYSTYRENE INSULATION

6 MIL. POLY VAPOR BARRIER

4" Ø P.V.C. PERF.

MIN. 6" DEEP

2'-0"

FOOTING ADJUST AS REQUIRED FOR SOIL CONDITIONS

#4 REBAR

3/4" CRUSHED WASHED STONE

2'-0"

3-#4 4BARS

FOOTING DRAINS @ BOTTOM OF FOOTING TYPICAL

FOOTING ADJUST AS REQUIRED FOR SOIL CONDITIONS

01 FD

TYPICAL FOUNDATION WALL SCALE 3/4"= 1'

02 FD

TYPICAL WALK-OUT FOUNDATION WALL SCALE 3/4"= 1'

1 22 " MIN.

07 FD

DETAIL @ GARAGE DOOR SCALE 1"= 1'

CLEAR LEDGE OF DUST & ROCK DEBRIS @ FOOTING

ANCHOR BOLTS @ 6' MAX. TYP.

TYPICAL HEATED 4" CONC. SLAB

SLAB REINFORCEMENT

FOOTING ON LEDGE

2-# 4BARS WHERE FOOTING RESTS ON LEDGE

USE # 4-BARS @ 4' O.C. DRILL MIN. 10" DEEP SECURE WITH "EPOXY TIE ADHESIVE" BY SIMPSON, OR EQUAL EXPANSION JOINT AND FILLER

P.T. SILL ON SILL SEALER

2 HORZ. # 4 BARS

HEAT TUBES

LOCATE PINS ON HIGH POINTS OF LEDGE

T.O.W.

GRADE VAOPR BARRIER

FOOTING ON LEDGE SCALE 1"= 1'

TIMBER POST

(2) #4 REBARS ALL AROUND TOP OF FOUNDATION WALL; BEND AROUND CORNERS & LAPS SPLICES 6" MIN

FOOTING BELOW FROST LINE OR TO LEDGE

3/4" CRUSHED WASHED STONE MIN. 6" DEEP

MIN. 4" REINFORCED CEM. CONC. SLAB

MOISTURE BARRIER SEAL TO FOOTING OR WALL

8" THICK FOUNDATION WALL WATERPROOFING

VERTICAL # 4 BAR @ 30" O.C MAX.

6'-0"

5" REINFORCED SLAB TOP FININSH -STAINED START SLOPE AT MIDPOINT ELEVATION =103'-6"

2" STYROFOAM INSULATION

2" STYROFOAM INSULATION

6"

# 4 BARS 24" O.C. EA. WAY

GRADE

Crushed gravel back fill

FILTER FABRIC

Crushed gravel back fill

FILTER FABRIC

FOOTING BELOW FROST LINE OR TO LEDGE

CAST-IN PLACE POST BASE UPLIFT RESISTANT

8" THICK FOUNDATION WALL

#4 BARS VERTICAL @ 24" O.C. LAP 10" ON HOOKS

# 4 BARS 24" O.C. EA. WAY

SLAB SLOPES 1/4:12"

3/4" CRUSHED WASHED STONE MIN. 6" DEEP

8"

FINAL DRAFT

# 4 HOOKS @ 24" O.C.

8" REINFORCED FROST WALL

# 4 HOOKS @ 24" O.C.

EXISTING GRADE

CRUSHED STONE BACK FILL

COVER DRAIN PIPE WITH MIN. 12" OF CRUSHED STONE 4" Ø P.V.C. FOOTING DRAINS @ BOTTOM OF FOOTING TYPICAL

COVER DRAIN PIPE WITH MIN. 12" OF CRUSHED STONE

COMPACTED SAND

4" Ø P.V.C. FOOTING DRAINS @ BOTTOM OF FOOTING TYPICAL

FOOTING BEARS ON SOLID LEDGE OTHERWISE TO BELOW FROST LEVEL

TYPICAL FOOTING

05 FD

FROST WALL SCALE 1"= 1'

05 FD

BREEZEWAY SCALE 1"= 1'

06 FD

TYPICAL GARAGE FOUNDATION SCALE 1"= 1'

copyright 2009 Alces Post & Beam, Inc.

FD

Warren, Vermont

sheet #

HEATED

MIN. 4" REINFORCED CEM. CONC. SLAB

# 4 HOOKS @ 24" O.C.

GRADE

ALCES

2-5/8" SILL OVERHANG

I.C.F. 3" HEIGHT ADJUSTERS

2" STYROFOAM INSULATION

8"

4"

FLOOR FRMAING

2" STYROFOAM INSULATION

1'-0" NO INS.

POST & BEAM

P.O. Box 953 Waitsfield, Vermont 05673 Ky Koitzsch 802-496-5784

Information

1 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

667906


You might also be interested in

BETA
MIL-HDBK-1027/3B Range Facilities and Miscellaneous Training Facilities Other Than Buildings
post and pier block foundation
Designing & Bldg. Domed Obs.pdf
Microsoft Word - A220-Week1-Footings and Foundations.doc
MIL-HDBK-1027/3B Range Facilities and Miscellaneous Training Facilities Other Than Buildings