BRITISH STANDARD / UKOOA

Marine, Oil & Gas

Offshore Cables British Standard / UKOOA Program

Index

Flame retardant halogen-free earthing cable with enhanced oil resistance

RU 0.6/1 kv...........................................................................................................................2 RU 0.6/1 kv........................................................................................................4 RFCU(C) 250v -- Collective Screen....................................10 RFCU(I) 250v -- Individual Screen.......................................14 BFCU 0.6/1 kv .......................................................................18 BFCU(C) 250v -- Collective Screen..........22 BFCU(I) 250v -- Individual Screen..............26 RFCU 0.6/1 kv...................................................................................................6

Flame retardant halogen-free unarmoured power cable with enhanced oil resistance Flame retardant halogen-free armoured power cable with enhanced oil resistance

Flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance Flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance

Fire resistant, flame retardant halogen-free armoured power cable with enhanced oil resistance

Fire resistant, flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance Fire resistant, flame retardant halogen-free armoured instrumentation cable with enhanced oil resistance

UKOOA Coding System..................................................................................................................................................................................................................................................31 Technical Information Conductor resistance...................................................................................................................................................................................................................................32 Installation recommendations....................................................................................................................................................................................................................33 Voltage tests after installation...................................................................................................................................................................................................................34 Volt drop (RFCU power cable).....................................................................................................................................................................................................................35 Volt drop (BFCU power cable).....................................................................................................................................................................................................................36 Cable code designation.................................................................................................................................................................................................................................37

1

Marine, Oil & Gas RU 0.6/1KV Earthing cable

Flame retardant halogen-free earthing cable. Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90°C Operating Voltage Application Unarmoured cable for fixed installation for earthing purposes in safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS6883 BS6360 class 2 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 IEC60332-3-22 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Flame retardant Halogen Free Low Smoke

: 0.6/1kV

Construction Code Letter Conductor Insulation Inner sheath Armour/screen Outer sheath Marking text Outer sheath colour R Tinned stranded circular copper, BS6360, class 2 EP-rubber, GP4 to BS7655:section 1.2 No inner sheath, additional tapes may be applied No armour Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF) SW4 to BS7655 section 2.6. (Mud resistant version available on request) "metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied) Green/Yellow

U

Core identification Single core - off white

2

Marine, Oil & Gas RU 0.6/1KV Earthing cable

Range and dimensions

Number of cores 1 1 1 1 1 Cross section core, mm² 6 16 25 35 70 Thickness Conductor Insulation Outer Sheath, Diameter, mm Thickness, mm mm 3.15 5.15 6.45 7.65 10.85 1.0 1.0 1.2 1.2 1.4 1 1.1 1.2 1.2 1.3 Approx Overall Diameter, mm 7.5 9.5 11.5 12.5 16.5 Approx Weight Copper content of Cable Approx. (Kg/Km) (Kg/Km) 115 230 340 440 820 55 144 229 308 620

Ordering information

Part number 840080 840081 840082 840083 840084 Description RU 0.6/1kV 1X 6mm² RU 0.6/1kV 1X 16mm² RU 0.6/1kV 1X 25mm² RU 0.6/1kV 1X 35mm² RU 0.6/1kV 1X 70mm² Sheath Colour YELLOW/GREEN YELLOW/GREEN YELLOW/GREEN YELLOW/GREEN YELLOW/GREEN Design standard BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999

Electrical values

Number of cores Cross section core, mm² 6 16 25 35 70 Max. conductor resistance at 20°C, Ohm/km 3.11 1.16 0.734 0.529 0.27 Max. conductor resistance at 90°C, Ohm/km 3.97 1.48 0.936 0.675 0.344 Current rating IEC 60092-352 Table B.4, Ampere 52 96 127 157 242 Short circuit rating 1 second, Ampere 840 2240 3500 4900 9800

1 1 1 1 1

Ambient temperature correction factors

Ambient Temp °C Rating factor 35 1.11 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.75 70 0.67 75 0.50 80 0.47

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed OD < 25 mm - 4 x D, OD > 25 8xD mm - 6 x D Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

3

Marine, Oil & Gas RU 0.6/1KV Unarmoured power cable

Flame retardant halogen-free power cable. Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90°C Operating Voltage Application Unarmoured cable for fixed installation where cable protection is not required. Power, control and lighting in safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS6883 BS6360 class 2 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 IEC60332-3-22 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Flame retardant Halogen Free Low Smoke

: 0.6/1kV

Construction Code Letter Conductor Insulation Inner sheath Armour/screen Outer sheath Marking text Outer sheath colour R Tinned stranded circular copper, BS6360, class 2 EP-rubber, GP4 to BS7655:section 1.2 No inner sheath, additional tapes may be applied No armour Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF) SW4 to BS7655 section 2.6. (Mud resistant version available on request) "metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied) Black

U

Core identification All cores are offwhite with black numbers No 1,2,3.......

4

Marine, Oil & Gas RU 0.6/1KV Unarmoured power cable

Range and dimensions

Number of cores 2 2 3 3 3 3 4 4 3 3 Cross section core, mm² 1.5 2.5 1.5 2.5 4 6 1.5 2.5 10 16 Weight of Copper content Conductor Insulation Thickness Outer Approx Overall Cable Approx. Approx. Diameter, mm Thickness, mm Sheath, mm Diameter, mm (Kg/Km) (Kg/Km) 1.6 0.8 1.1 8.5 120 28 2.0 0.8 1.1 9.5 150 46 1.6 0.8 1.1 9 140 42 2.0 0.8 1.1 10 180 69 2.55 1.0 1.2 12 275 110 3.15 1.0 1.2 13.5 360 164 1.6 0.8 1.1 10 165 56 2.0 0.8 1.1 11 220 92 4.05 1.0 1.3 15.5 530 271 5.15 1.0 1.4 18 770 434

Ordering information

Part number 840300 840301 840302 840303 840304 840305 840306 840307 840312 840313 Description RU 0.6/1kV 2X 1.5mm² RU 0.6/1kV 2X 2.5mm² RU 0.6/1kV 3X 1.5mm² RU 0.6/1kV 3X 2.5mm² RU 0.6/1kV 3X 4mm² RU 0.6/1kV 3X 6mm² RU 0.6/1kV 4X 1.5mm² RU 0.6/1kV 4X 2.5mm² RU 0.6/1kV 3X 10mm² RU 0.6/1kV 3X 16mm² Sheath Colour BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Design standard BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999 BS 6883:1999

Electrical values

Number of cores Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating core, mm² resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 20°C, Ohm/km 90°C, Ohm/km Table B.4, Ampere 1.5 12.2 15.6 0.103 0.123 20 2.5 1.5 2.5 4 6 1.5 2.5 10 16 7.56 12.2 7.56 4.7 3.11 12.2 7.56 1.84 1.16 9.64 15.6 9.64 5.90 3.97 15.6 9.64 2.35 1.48 0.096 0.103 0.096 0.096 0.090 0.103 0.096 0.084 0.080 0.115 0.123 0.115 0.115 0.108 0.123 0.115 0.101 0.096 26 16 21 28 36 16 21 50 67 Short circuit rating 1 second, Ampere 210 350 210 350 560 840 210 350 1400 2240

2 2 3 3 3 3 4 4 3 3 Ambient Temp °C Rating factor

Ambient temperature correction factors

35 1.11 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.75 70 0.67 75 0.50 80 0.47

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed OD < 25 mm - 4 x D, OD > 25 8xD mm - 6 x D Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

5

Marine, Oil & Gas RFCU 0.6/1KV Power, Control or Lighting cable

Flame retardant halogen-free power cable. Enhanced oil-resistance.

RFCU 0.6/1kV

Operating temperature : 90°C Operating Voltage Application Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS6883 / UKOOA BS6360 class 2 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 IEC60332-3-22 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Flame retardant Halogen Free Low Smoke

: 0,6/1kV

Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour F R Tinned stranded circular copper, BS 6360, class 2 EP-rubber, GP4 to BS 7655: section 1.2 Cores laid up in concentric layers Flame retardant and halogen-free thermoset compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable actually supplied) Black

Core identification All cores are offwhite with black numbers No 1,2,3.......

6

Marine, Oil & Gas RFCU 0.6/1KV Power, Control or Lighting cable

Range and dimensions

Cross Conductor Insulation Number of section Diameter, Thickness, cores core, mm² mm mm 2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 4 7 12 19 4 3 3 4 19 4 4 2 4 37 2 27 7 12 2 3 4 3 5 1.5 2.5 4 1.5 2.5 4 6 16 35 70 1.5 4 6 16 25 35 2.5 2.5 2.5 70 10 25 10 1.5 50 95 6 6 2.5 16 2.5 1.5 1.5 35 50 2.5 95 1.5 1.6 2.0 2.55 1.6 2.0 2.55 3.15 5.15 7.65 10.85 1.6 2.55 3.15 5.15 6.45 7.65 2.0 2.0 2.0 10.85 4.05 6.45 4.05 1.6 9.0 12.60 3.15 3.15 2.0 5.15 2.0 1.6 1.6 7.65 9.0 2.0 12.60 1.6 0.8 0.8 1.0 0.8 0.8 1.0 1.0 1.0 1.2 1.4 0.8 1.0 1.0 1.0 1.2 1.2 0.8 0.8 0.8 1.4 1.0 1.2 1.0 0.8 1.4 1.6 1.0 1.0 0.8 1.0 0.8 0.8 0.8 1.2 1.4 0.8 1.6 0.8 Thickness Inner Sheath, mm 1.1 1.1 1.2 1.1 1.1 1.2 1.2 1.4 1.7 2 1.1 1.2 1.3 1.5 1.7 1.8 1.2 1.4 1.5 2.1 1.3 1.6 1.4 1.4 1.9 2.3 1.2 1.3 1.8 1.4 1.7 1.2 1.3 1.6 1.8 1.1 2.2 1.1 Approx Thickness Approx Diameter Diameter Outer Overall inner Braid Wire, Sheath, Diameter, Sheath, mm mm mm mm 8.5 9.5 11.5 9 10 12.5 13.5 18.5 25.5 34 10 13.5 15 20.5 25 28 13.5 18 21 38 16 22.5 17.5 19 33 43.5 13 15 29 17.5 25.5 12 16 23.5 29.5 11 39 11 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.3 0.3 0.3 0.3 0.45 0.45 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.45 0.45 0.3 0.3 0.45 0.3 0.45 0.3 0.3 0.3 0.45 0.3 0.45 0.3 1.2 1.2 1.3 1.2 1.3 1.3 1.4 1.6 1.9 2.2 1.3 1.4 1.5 1.7 1.9 2 1.4 1.6 1.7 2.4 1.5 1.8 1.6 1.6 2.2 2.6 1.4 1.5 2 1.5 1.9 1.3 1.5 1.8 2 1.3 2.4 1.3 12.5 13.5 15.5 13 14 16.5 18 23 31 40 14 18 19.5 25.5 31 34 18.5 22.5 27 44 20.5 28 22.5 24 39.5 50.5 17 19.5 35 22 31.5 17 20.5 28.5 35 15 45 15 Weight of Cable Approx. (Kg/Km) 280 320 440 310 360 490 610 1120 2150 3770 350 590 740 1390 2130 2620 590 900 1240 4670 830 1640 1000 960 3480 6080 540 740 2270 940 1820 470 710 1650 2830 420 4860 440 Copper content Approx. (kg/km) 28 46 74 42 69 110 164 434 927 1863 56 147 218 578 917 1236 161 275 435 2484 271 688 361 264 1716 3351 109 218 847 289 618 98 167 618 1287 92 2513 83

7

Marine, Oil & Gas RFCU 0.6/1KV Power, Control or Lighting cable

Ordering information

Part number 840049 840050 840051 840052 840053 840054 840055 840056 840057 840058 840059 840061 840062 840063 840064 840065 840068 840070 840071 840088 840154 840158 840159 840160 840166 840242 840245 840246 840256 840258 840262 840263 840264 840269 840283 840284 840311 840338 Description RFCU 0.6/1kV 2X 1.5mm² RFCU 0.6/1kV 2X 2.5mm² RFCU 0.6/1kV 2X 4mm² RFCU 0.6/1kV 3X 1.5mm² RFCU 0.6/1kV 3X 2.5mm² RFCU 0.6/1kV 3X 4mm² RFCU 0.6/1kV 3X 6mm² RFCU 0.6/1kV 3X 16mm² RFCU 0.6/1kV 3X 35mm² RFCU 0.6/1kV 3X 70mm² RFCU 0.6/1kV 4X 1.5mm² RFCU 0.6/1kV 4X 4mm² RFCU 0.6/1kV 4X 6mm² RFCU 0.6/1kV 4X 16mm² RFCU 0.6/1kV 4X 25mm² RFCU 0.6/1kV 4X 35mm² RFCU 0.6/1kV 7X 2.5mm² RFCU 0.6/1kV 12X 2.5mm² RFCU 0.6/1kV 19X 2.5mm² RFCU 0.6/1kV 4X 70mm² RFCU 0.6/1kV 3X 10mm² RFCU 0.6/1kV 3X 25mm² RFCU 0.6/1kV 4X 10mm² RFCU 0.6/1kV 19X 1.5mm² RFCU 0.6/1kV 4X 50mm² RFCU 0.6/1kV 4X 95mm² RFCU 0.6/1kV 2X 6mm² RFCU 0.6/1kV 4X 6mm² RFCU 0.6/1kV 37X 2.5mm² RFCU 0.6/1kV 2X 16mm² RFCU 0.6/1kV 27X 2.5mm² RFCU 0.6/1kV 7X 1.5mm² RFCU 0.6/1kV 12X 1.5mm² RFCU 0.6/1kV 2X 35mm² RFCU 0.6/1kV 3X 50mm² RFCU 0.6/1kV 4X 2.5mm² RFCU 0.6/1kV 3X 95mm² RFCU 0.6/1kV 5X 1.5mm² Sheath Colour BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Design standard BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 UKOOA Code WB202 WB203 WB204 WB302 WB303 WB304 WB306 WB316 WB335 WB370 WB402 WB404 WB406 WB416 WB425 WB435 WB703 WBA03 WBB03 WB470 WB310 WB325 WB410 WBB02 WB450 WB495 WB206 WB406 WBD03 WB216 WBC03 WB702 WBA02 WB235 WB350 WB403 WB395 -

8

Marine, Oil & Gas RFCU 0.6/1KV Power, Control or Lighting cable

Electrical values

Number of cores Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating core, mm² resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 20°C, Ohm/km 90°C, Ohm/km Table B.4, Ampere 1.5 2.5 4 1.5 2.5 4 6 16 35 70 1.5 4 6 16 25 35 2.5 2.5 2.5 70 10 25 10 1.5 50 95 6 6 2.5 16 2.5 1.5 1.5 35 50 2.5 95 1.5 12.2 7.56 4.7 12.2 7.56 4.7 3.11 1.16 0.529 0.27 12.2 4.7 3.11 1.16 0.734 0.529 7.56 7.56 7.56 0.27 1.84 0.734 1.84 12.2 0.391 0.195 3.11 3.11 7.56 1.16 7.56 12.2 12.2 0.529 0.391 7.56 0.195 12.2 15.6 9.64 5.99 15.6 9.64 5.99 3.97 1.48 0.675 0.344 15.6 5.99 3.97 1.48 0.936 0.675 9.64 9.64 9.64 0.344 2.35 0.936 2.35 15.6 0.499 0.249 3.97 3.97 9.64 1.48 9.64 15.6 15.6 0.675 0.499 9.64 0.249 15.6 0.103 0.096 0.096 0.103 0.096 0.096 0.090 0.080 0.076 0.074 0.103 0.096 0.090 0.080 0.079 0.076 0.096 0.096 0.096 0.074 0.084 0.079 0.084 0.103 0.076 0.073 0.090 0.090 0.096 0.080 0.096 0.103 0.103 0.076 0.076 0.096 0.073 0.103 0.123 0.115 0.115 0.123 0.115 0.115 0.108 0.096 0.092 0.088 0.123 0.115 0.108 0.096 0.095 0.092 0.115 0.115 0.115 0.088 0.101 0.095 0.101 0.123 0.092 0.088 0.108 0.108 0.115 0.096 0.115 0.123 0.123 0.092 0.092 0.115 0.088 0.123 20 26 34 16 21 28 36 67 110 169 16 28 36 67 89 110 15.5 13 11 169 50 89 50 8.5 137 205 44 36 9 80 10 12 10 133 137 21 205 13.5 Short circuit rating 1 second, Ampere 210 350 560 210 350 560 840 2240 4900 9800 210 560 840 2240 3500 4900 350 350 350 9800 1400 3500 1400 210 7000 13300 840 840 350 2240 350 210 210 4900 7000 350 13300 210

2 2 2 3 3 3 3 3 3 3 4 4 4 4 4 4 7 12 19 4 3 3 4 19 4 4 2 4 37 2 27 7 12 2 3 4 3 5

Ambient temperature correction factors

Ambient Temp °C Rating factor 35 1.11 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.75 70 0.67 75 0.50 80 0.47

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed OD < 25 mm - 4 x D, OD > 25 8xD mm - 6 x D Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

9

Marine, Oil & Gas RFCU(C) 250V, Collective screened instrumentation

Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

RFCU(C) 250V

Operating temperature : 90°C Operating Voltage Application Fixed installation for instrumentation, communication, control and alarm systems in both EX­ and safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS6883 / UKOOA BS6360 class 2 or 5 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 IEC60332-3-22 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Flame retardant Halogen Free Low Smoke

: 250V

Construction Code Letter Conductor Insulation Pair/Triple/Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour F R Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2) EP-rubber, GP4 to BS 7655: section 1.2 Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with aluminium backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoset compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "RFCU(C)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-322" (marking may differ on cable actually supplied) Grey or Blue

Core identification Pair Black--White, numbered 1-1, 2-2, 3-3 ...... Triple-- Black--White--Red, numbered 1-1-1, 2-2-2, 3-3-3 ...... Quad-- Black--White--Red--Blue, numbered 1-1-1-1, 2-2-2-2 ..... Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

10

Marine, Oil & Gas RFCU(C) 250V, Collective screened instrumentation

Range and dimensions

Number of elements 3 7 12 27 3 7 12 19 27 2 20 20 7 12 20 27 7 12 3 3 3 3 3 12 3 5 2 2 5 Thickness Diameter Thickness Approx Weight of No of Cross Conductor Insulation Diameter Inner Inner Outer Overall Cable cores in section Diameter, Thickness Braid Sheath, Sheath, Sheath, Diameter , Approx. element core, mm² mm mm Wire, mm mm mm mm mm (Kg/Km) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 2 2 2 3 3 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1 0.75 0.75 1.5 1.5 1.5 1.5 0.75 0.75 0.75 1.5 1.5 1 0.75 1.5 1.5 1.5 0.75 1.5 0.75 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.3 1.15 1.15 1.6 1.6 1.6 1.6 1.15 1.15 1.15 1.6 1.6 1.3 1.15 1.6 1.6 1.6 1.15 1.6 1.15 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.2 1.4 1.6 1.9 1.2 1.4 1.6 1.7 1.9 1.2 1.8 1.8 1.4 1.7 1.9 2.1 1.4 1.7 1.3 1.3 1.3 1.2 1.3 1.8 1.3 1.4 1.2 1.2 1.3 12 16.5 21.5 29 12 16.5 21.5 24.5 29 12 25.5 25.5 18.5 24.5 29 33.5 18 24 13.5 14 14 12.5 13.5 27.5 14 17 11.5 13 15 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.45 0.45 0.3 0.45 0.45 0.3 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.3 1.4 1.5 1.7 2.2 1.4 1.5 1.7 1.9 2.2 1.4 2 2 1.6 1.9 2.2 2.4 1.6 1.9 1.4 1.4 1.4 1.4 1.4 2 1.4 1.6 1.3 1.4 1.5 16.5 21 26 35.5 16.5 21 26 30 35.5 16.5 31.5 31.5 23 30 35.5 40 22.5 29 18 18 18 17 18 33.5 18 21.5 15.5 17 19.5 420 660 1000 1980 420 660 1000 1460 1980 400 1570 1570 850 1470 2130 2650 820 1290 510 520 520 460 510 1840 520 730 370 450 570 Copper content Approx. (kg/km) 45 97 164 359 45 97 164 257 359 41 271 271 183 309 511 687 144 244 65 82 82 58 65 461 82 132 31 57 71

11

Marine, Oil & Gas RFCU(C) 250V, Collective screened instrumentation

Electrical values Type Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² Unshielded pair 1,0 mm² Unshielded triple 1,0 mm² Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² Ordering information

Part number 840003 840004 840005 840007 840023 840024 840025 840026 840027 840117 840128 840156 840176 840177 840178 840179 840222 840223 840231 840236 840237 840241 840274 840277 840294 840295 840332 840333 840334 Description RFCU(C) 250V 3PAIR 0.75mm² RFCU(C) 250V 7PAIR 0.75mm² RFCU(C) 250V 12PAIR 0.75mm² RFCU(C) 250V 27PAIR 0.75mm² RFCU(C) 250V 3PAIR 0.75mm² RFCU(C) 250V 7PAIR 0.75mm² RFCU(C) 250V 12PAIR 0.75mm² RFCU(C) 250V 19PAIR 0.75mm² RFCU(C) 250V 27PAIR 0.75mm² RFCU(C) 250V 2PAIR 1mm² RFCU(C) 250V 20PAIR 0.75mm² RFCU(C) 250V 20PAIR 0.75mm² RFCU(C) 250V 7PAIR 1.5mm² RFCU(C) 250V 12PAIR 1.5mm² RFCU(C) 250V 20PAIR 1.5mm² RFCU(C) 250V 27PAIR 1.5mm² RFCU(C) 250V 7TRIP 0.75mm² RFCU(C) 250V 12TRIP 0.75mm² RFCU(C) 250V 3TRIP 0.75mm² RFCU(C) 250V 3PAIR 1.5mm² RFCU(C) 250V 3PAIR 1.5mm² RFCU(C) 250V 3PAIR 1mm² RFCU(C) 250V 3TRIP 0.75mm² RFCU(C) 250V 12TRIP 1.5mm² RFCU(C) 250V 3PAIR 1.5mm² RFCU(C) 250V 5PAIR 1.5mm² RFCU(C) 250V 2PAIR 0.75mm² RFCU(C) 250V 2PAIR 1.5mm² RFCU(C) 250V 5PAIR 0.75mm² Sheath Colour GREY GREY GREY GREY BLUE BLUE BLUE BLUE BLUE GREY GREY BLUE GREY GREY GREY GREY BLUE BLUE GREY BLUE GREY GREY GREY BLUE GREY GREY GREY GREY GREY Design standard BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 UKOOA Code KJH00 KJJ00 KJK00 KJM00 KGH00 KGJ00 KGK00 KGM00 KJL00 KGL00 KJJ02 KJK02 KJL02 KJM02 KGT00 KGU00 KJS00 KGH02 KJH02 KJH01 KJS00 KGU02 KJH02 -

Inductance, Capacitance, approx, (mH/ approx. (nF/km) km) 80 80 85 85 90 90 90 90 0,75 0,75 0,73 0,73 0,68 0,68 0,70 0,70

Resistance at 20°C, max. (Ohm/km) 26,7 26,7 20,0 20,0 13,7 13,7 7,56 7,56

L/R ratio, (microH/Ohm) 14 14 18 18 24,8 24,8 46,3 46,3

Insulation resistance (Minimum Mohm x km) 940 940 840 840 730 730 620 620

12

Marine, Oil & Gas RFCU(C) 250V, Collective screened instrumentation

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed 10 x D 8xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

13

Marine, Oil & Gas RFCU(I) 250V, Individual screened instrumentation

Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

RFCU(I) 250V

Operating temperature : 90°C Operating Voltage Application Fixed installation for instrumentation, communication, control and alarm systems in both EX­ and safe areas. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS6883 / UKOOA BS6360 class 2 or 5 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 IEC60332-3-22 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Flame retardant Halogen Free Low Smoke

: 250V

Construction Code Letter Conductor Insulation R Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2) EP-rubber, GP4 to BS 7655: section 1.2 Colour coded cores twisted together to form a pair, triple or quad, which is individually screened with aluminium backed polyester tape with a tinned copper drain wire. Each pair, triple or quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs, triples or quads. Individually shielded pairs, triples or quads are laid up in concentric layers and wrapped with a PETP tape. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoset compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "RFCU(I)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-322" (marking may differ on cable actually supplied) Grey or Blue

Pair/Triple/Quad twisting / lay up

Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour

F

Core identification Pair Black--White, numbered 1-1, 2-2, 3-3 ...... Triple-- Black--White--Red, numbered 1-1-1, 2-2-2, 3-3-3 ...... Quad-- Black--White--Red--Blue, numbered 1-1-1-1, 2-2-2-2 ..... Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

14

Marine, Oil & Gas RFCU(I) 250V, Individual screened instrumentation

Range and dimensions

Number of elements 1 1 1 1 1 1 1 3 1 7 12 7 7 12 12 3 3 3 20 19 12 7 3 3 3 1 1 1 1 1 1 Approx Thickness Thickness Approx Weight of No of Cross Conductor Insulation Diameter Diameter Inner Outer Overall Cable cores in section Diameter, Thickness Braid Inner Sheath, Sheath, Diameter Approx. element core, mm² mm mm Sheath, Wire, mm mm mm mm (Kg/Km) mm 2 4 2 4 2 2 4 2 3 3 3 2 2 2 2 3 2 2 2 2 3 3 2 3 2 2 3 3 4 4 3 0.75 0.75 0.75 0.75 1 1 1 1 1 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 0.75 0.75 0.75 1.5 0.75 1.5 1.5 1.5 0.75 1 1.5 1.5 1.15 1.15 1.15 1.15 1.3 1.3 1.3 1.3 1.3 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.6 1.15 1.15 1.15 1.6 1.15 1.6 1.6 1.6 1.15 1.3 1.6 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1 1.2 1 1.2 1 1 1.2 1.3 1.1 1.5 1.7 1.4 1.4 1.6 1.6 1.3 1.2 1.2 2 1.8 1.7 1.5 1.3 1.3 1.3 1.1 1.1 1 1.2 1.2 1.1 7.5 9 7.5 9 8 8 9.5 13 8.5 18.5 25 16.5 16.5 22 22 14 12 12 31.5 26 25 18.5 14 14 14 8.5 9 8 9.5 10 9 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 1.2 1.3 1.2 1.3 1.2 1.2 1.4 1.4 1.2 1.7 2 1.6 1.6 1.8 1.8 1.5 1.4 1.4 2.3 2 2 1.7 1.5 1.5 1.5 1.2 1.2 1.2 1.4 1.4 1.2 11.5 13.5 11.5 13.5 12 12 14 17 12.5 23.5 31 21 21 27 27 18.5 16.5 16.5 38 32 31 23.5 18.5 18.5 18.5 12.5 13 12 14 14.5 13 230 310 230 310 240 240 340 490 285 900 1530 720 720 1110 1110 530 430 430 2430 1660 1530 900 560 530 560 290 320 245 340 370 320 Copper content Approx. (kg/km) 18 31 18 31 24 24 41 71 32 170 293 124 124 212 212 73 53 53 635 336 293 170 95 73 95 32 45 25 41 57 45

15

Marine, Oil & Gas RFCU(I) 250V, Individual screened instrumentation

Electrical values Type Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded quad 0,75 mm² Shielded pair 1 mm² Shielded triple 1 mm² Shielded quad 1 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded quad 1,5 mm² Shielded pair 2,5 mm² Ordering information

Part number 840001 840002 840021 840022 840094 840095 840096 840100 840121 840211 840212 840214 840215 840216 840221 840224 840226 840227 840235 840238 840239 840272 840275 840276 840278 840293 840296 840335 840336 840337 840339 Description RFCU(I) 250V 1PAIR 0.75mm² RFCU(I) 250V 1QUAD 0.75mm² RFCU(I) 250V 1PAIR 0.75mm² RFCU(I) 250V 1QUAD 0.75mm² RFCU(I) 250V 1PAIR 1mm² RFCU(I) 250V 1PAIR 1mm² RFCU(I) 250V 1QUAD 1mm² RFCU(I) 250V 3PAIR 1mm² RFCU(I) 250V 1TRIP 1mm² RFCU(I) 250V 7TRIP 0.75mm² RFCU(I) 250V 12TRIP 0.75mm² RFCU(I) 250V 7PAIR 0.75mm² RFCU(I) 250V 7PAIR 0.75mm² RFCU(I) 250V 12PAIR 0.75mm² RFCU(I) 250V 12PAIR 0.75mm² RFCU(I) 250V 3TRIP 0.75mm² RFCU(I) 250V 3PAIR 0.75mm² RFCU(I) 250V 3PAIR 0.75mm² RFCU(I) 250V 20PAIR 1.5mm² RFCU(I) 250V 19PAIR 0.75mm² RFCU(I) 250V 12TRIP 0.75mm² RFCU(I) 250V 7TRIP 0.75mm² RFCU(I) 250V 3PAIR 1.5mm² RFCU(I) 250V 3TRIP 0.75mm² RFCU(I) 250V 3PAIR 1.5mm² RFCU(I) 250V 1PAIR 1.5mm² RFCU(I) 250V 1TRIP 1.5mm² RFCU(I) 250V 1TRIP 0.75mm² RFCU(I) 250V 1QUAD 1mm² RFCU(I) 250V 1QUAD 1.5mm² RFCU(I) 250V 1TRIP 1.5mm² Sheath Colour GREY GREY BLUE BLUE GREY BLUE BLUE BLUE GREY BLUE BLUE GREY BLUE GREY BLUE BLUE GREY BLUE GREY BLUE GREY GREY GREY GREY BLUE GREY GREY GREY GREY GREY BLUE Design standard BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1999 BS 6883 : 1999 BS 6883 : 1991 BS 6883 : 1991 UKOOA Code KKF00 KKX00 KHF00 KHX00 KKF01 KHF01 KHX01 KHH01 KKR01 KHT00 KHU00 KKJ00 KHJ00 KKK00 KHK00 KHS00 KKH00 KHH00 KKL02 KKU00 KKT00 KKH02 KKS00 KHH02 KKF02 KKR02 KKR00 KKX01 KKX02 KHR02

Inductance, Capacitance, Resistance at 20°C, L/R ratio, (microH/ approx (mH/ approx. (nF/km) max. (Ohm/km) Ohm) km) 90 90 60 100 100 70 110 110 80 120 0,75 0,75 0,91 0,73 0,73 0,95 0,68 0,68 0,99 0,70 26,7 26,7 26,7 20,0 20,0 20,0 13,7 13,7 13,7 7,56 14 14 14 18 18 18 24,8 24,8 24,8 46,3

Insulation resistance (Minimum MOhmx km) 940 940 940 840 840 840 730 730 730 620

16

Marine, Oil & Gas RFCU(I) 250V, Individual screened instrumentation

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed 10 x D 8xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

17

Marine, Oil & Gas BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Fire resistant, Flame retardant halogen-free power cable. Enhanced oil-resistance.

BFCU 0.6/1kV

Operating temperature : 90°C Operating Voltage Application Armoured cable for fixed installation for power, control or lighting in both EX and safe areas, emergency and critical systems where there is a requirement for fire resistant cables. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS7917/BS6883/UKOOA BS6360 class 2 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 &3-22 IEC60331-21 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Fire Resistant Halogen Free Low Smoke

: 0.6/1kV

Construction Code Letter Conductor Insulation Lay up / Shielding Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour F B Tinned stranded circular copper, BS 6360, class 2 Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2 Cores laid up in concentric layers Flame retardant and halogen-free thermoplastic EP-rubber based compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number of cores" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied) Black

Core identification All cores are offwhite with black numbers No 1,2,3.......

18

Marine, Oil & Gas BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Range and dimensions

Number of cores 2 3 3 4 4 7 12 27 19 4 3 2 12 3 2 3 2 3 2 2 4 4 2 3 3 3 3 4 3 7 Cross Conductor Insulation section Diameter, Thickness, core, mm² mm mm 2.5 1.5 2.5 1.5 2.5 2.5 2.5 2.5 2.5 70 4 1.5 1.5 6 4 10 10 25 6 16 6 35 35 35 16 50 70 4 95 1.5 2.0 1.6 2.0 1.6 2.0 2.0 2.0 2.0 2.0 10.85 2.55 1.6 1.6 3.15 2.55 4.05 4.05 6.45 3.15 5.15 3.15 7.65 7.65 7.65 5.15 9.0 10.85 2.55 12.60 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.4 1.0 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.0 1.0 1.0 1.2 1.2 1.2 1.0 1.4 1.4 1.0 1.6 0.8 Thickness Inner Sheath, mm 1.1 1.1 1.1 1.1 1.1 1.2 1.4 1.7 1.5 2.1 1.2 1.1 1.3 1.2 1.2 1.3 1.3 1.6 1.2 1.4 1.3 1.8 1.6 1.7 1.4 1.8 2 1.2 2.2 1.2 Approx Thickness Approx Diameter Diameter Outer Overall Braid Wire, Inner Sheath, Diameter, mm Sheath, mm mm mm 10 0.3 1.2 14 10 10.5 11 11.5 14 19 27.5 22.5 38 13 9.5 17.5 14.5 12.5 16.5 15.5 23.5 13.5 18 16 29 24.5 26 19 30.5 34.5 14.5 39.5 13 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.45 0.3 0.45 0.45 0.3 0.45 0.3 1.2 1.3 1.3 1.3 1.4 1.6 1.9 1.7 2.4 1.3 1.2 1.5 1.4 1.3 1.5 1.4 1.8 1.4 1.5 1.5 2 1.8 1.9 1.6 2 2.2 1.4 2.4 1.3 14 15 15 16 18.5 24 33.5 27.5 45 17 13 22 18.5 16.5 21 20 28.5 18 22.5 20.5 35 29.5 32 24 36.5 41 18.5 46.5 17 Weight of Cable Approx. (Kg/Km) 350 340 410 400 450 620 960 1900 1360 4650 540 295 770 650 470 840 710 1710 570 780 790 2700 1740 2210 1160 2890 3810 630 4950 520 Copper content Approx. (kg/km) 46 42 69 56 92 161 275 618 435 2484 110 28 167 164 74 271 181 688 109 289 218 1236 618 927 434 1293 1863 147 2513 98

19

Marine, Oil & Gas BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Ordering information

Part number 840073 840074 840075 840076 840077 840078 840079 840108 840136 840151 840153 840162 840165 840167 840230 840233 840243 840248 840249 840250 840257 840259 840270 840273 840297 840298 840299 840308 840309 840310 Description BFCU 0.6/1kV 2X 2.5mm² BFCU 0.6/1kV 3X 1.5mm² BFCU 0.6/1kV 3X 2.5mm² BFCU 0.6/1kV 4X 1.5mm² BFCU 0.6/1kV 4X 2.5mm² BFCU 0.6/1kV 7X 2.5mm² BFCU 0.6/1kV 12X 2.5mm² BFCU 0.6/1kV 27X 2.5mm² BFCU 0.6/1kV 19X 2.5mm² BFCU 0,6/1kV 4X 70 MM2 BFCU 0.6/1kV 3X 4mm² BFCU 0.6/1kV 2X 1.5mm² BFCU 0,6/1kV 12X 1,5mm2 BFCU 0.6/1kV 3X 6mm² BFCU 0.6/1kV 2X 4mm² BFCU 0.6/1kV 3X 10mm² BFCU 0,6/1kV 2X 10MM2 BFCU 0.6/1kV 3X 25mm² BFCU 0.6/1kV 2X 6mm² BFCU 0,6/1kV 2X 16 MM2 BFCU 0.6/1kV 4X 6mm² BFCU 0.6/1kV 4X 35mm² BFCU 0.6/1kV 2X 35mm² BFCU 0.6/1kV 3X 35mm² BFCU 0.6/1kV 3X 16mm² BFCU 0.6/1kV 3X 50mm² BFCU 0.6/1kV 3X 70mm² BFCU 0.6/1kV 4X 4mm² BFCU 0.6/1kV 3X 95mm² BFCU 0.6/1kV 7X 1.5mm² Sheath Colour BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK Design standard BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 UKOOA Code YD203 YD302 YD303 YD402 YD403 YD703 YDA03 YDC03 YDB03 YD470 YD304 YD202 YDA02 YD306 YD204 YD310 YD210 YD325 YD206 YD216 YD406 YD435 YD235 YD335 YD316 YD350 YD370 YD404 YD370 YD702

20

Marine, Oil & Gas BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Electrical values

Number of cores Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating core, mm² resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 20°C, Ohm/km 90°C, Ohm/km Table B.4, Ampere 2.5 1.5 2.5 1.5 2.5 2.5 2.5 2.5 2.5 70 4 1.5 1.5 6 4 10 10 25 6 16 6 35 35 35 16 50 70 4 95 1.5 7.56 12.2 7.56 12.2 7.56 7.56 7.56 7.56 7.56 0.27 4.7 12.2 12.2 3.11 4.7 1.84 1.84 0.734 3.11 1.16 3.11 0.529 0.529 0.529 1.16 0.391 0.27 4.7 0.195 12.2 9.64 15.6 9.64 15.6 9.64 9.64 9.64 9.64 9.64 0.344 5.99 15.6 15.6 3.97 5.99 2.35 2.35 0.936 3.97 1.48 3.97 0.675 0.675 0.675 1.48 0.499 0.344 5.99 0.249 15.6 0.101 0.108 0.101 0.108 0.101 0.101 0.101 0.101 0.101 0.075 0.100 0.108 0.108 0.094 0.100 0.088 0.088 0.081 0.094 0.082 0.094 0.078 0.078 0.078 0.082 0.078 0.075 0.100 0.075 0.108 0.121 0.130 0.121 0.130 0.121 0.121 0.121 0.121 0.121 0.090 0.120 0.130 0.130 0.112 0.120 0.105 0.105 0.097 0.112 0.099 0.112 0.094 0.094 0.094 0.099 0.093 0.090 0.120 0.090 0.130 26 16 21 16 21 15.5 13 10 11 169 28 20 10 36 34 50 61 89 44 80 36 110 133 110 67 137 169 28 205 12 Short circuit rating 1 second, Ampere 350 210 350 210 350 350 350 350 350 9800 560 210 210 840 560 1400 1400 3500 840 2240 840 4900 4900 4900 2240 7000 9800 560 13300 210

2 3 3 4 4 7 12 27 19 4 3 2 12 3 2 3 2 3 2 2 4 4 2 3 3 3 3 4 3 7

Ambient temperature correction factors

Ambient Temp °C Rating factor 35 1.11 40 1.05 45 1.00 50 0.94 55 0.88 60 0.82 65 0.75 70 0.67 75 0.50 80 0.47

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed OD < 25 mm - 4 x D, OD > 25 8xD mm - 6 x D Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

21

Marine, Oil & Gas BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Fire resistant, Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

BFCU(C) 250V

Operating temperature : 90°C Operating Voltage Application Fixed installation for instrumentation, communication, control and alarm systems in both EX­ and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Standards applied

BS7917/BS6883/UKOOA BS6360 class 2 or 5 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 & 3-22 IEC60331-21 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Fire Resistant Halogen Free Low Smoke

: 250V

Construction Code Letter Conductor Insulation Pair/Triple/Quad twisting Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour F B Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2) Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2 Colour coded cores twisted together to form a pair, triple or quad, wrapped with polyester tape. Pairs, triples or quads are laid up, collectively screened with aluminium backed polyester tape with tinned copper drain wire. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic EP-rubber based compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied) Grey or Blue

Core identification Pair Black--White, numbered 1-1, 2-2, 3-3 ...... Triple-- Black--White--Red, numbered 1-1-1, 2-2-2, 3-3-3 ...... Quad-- Black--White--Red--Blue, numbered 1-1-1-1, 2-2-2-2 ..... Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

22

Marine, Oil & Gas BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Range and dimensions

Approx Thickness Thickness Approx Weight of No of Cross Conductor Insulation Diameter Diameter Inner Outer Overall Cable Inner cores in section Diameter, Thickness Braid Sheath, Sheath, Diameter Approx. element core, mm² mm mm Sheath, Wire, mm mm mm mm (Kg/Km) mm 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 2 2 2 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1 1.5 0.75 1.5 1.5 1.5 0.75 1.5 1.5 0.75 0.75 2.5 2.5 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 0.75 1 0.75 0.75 1.5 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.3 1.6 1.15 1.6 1.6 1.6 1.15 1.6 1.6 1.15 1.15 2 2 1.15 1.15 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.15 1.3 1.15 1.15 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.2 1.4 1.6 1.7 1.9 1.2 1.4 1.6 1.7 1.9 1.2 1.2 1.8 1.3 1.4 1.7 1.8 1.9 2.1 1.4 1.7 1.3 1.8 1.2 1.3 1.5 1.8 1.4 1.9 1.2 1.3 1.4 1.4 1.4 1.2 1.2 1.3 1.3 1.7 13 17.5 22.5 26 31 13 17.5 22.5 26 31 13.5 13.5 27 14.5 19.5 26 27 31 35.5 19.5 26 16 28.5 12 15 22 29.5 19.5 31 13.5 ± 0.8 14.5 ± 0.8 18 ± 0.8 18 ± 0.8 19.5 ± 0.8 12 ± 0.8 13.5 ± 0.8 15.5 ± 0.8 15.5 ± 0.8 26 ± 1 0.3 0.3 0.3 0.45 0.45 0.3 0.3 0.3 0.45 0.45 0.3 0.3 0.45 0.3 0.3 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.45 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 1.4 1.5 1.7 1.9 2.2 1.4 1.5 1.7 1.9 2.2 1.4 1.4 2 1.4 1.6 1.9 2 2.2 2.4 1.6 1.9 1.5 2 1.3 1.4 1.7 2 1.6 2.2 1.4 1.4 1.6 1.6 1.6 1.3 1.4 1.5 1.5 1.9 17.5 22 27.5 32 37.5 17.5 22 27.5 32 37.5 18 18 33 19 24 31.5 33 37.5 42 24.5 31.5 20.5 34.5 16.5 19 27 35.5 24 37.5 18 ± 0.8 19 ± 0.8 22.5 ± 1 22.5 ± 1 24 ± 1 16.5 ± 0.8 18 ± 0.8 20 ± 1 20 ± 1 31.5 ± 1.5 460 740 1120 1600 2190 460 740 1120 1600 2190 490 470 1720 570 920 1560 1720 2260 2820 930 1450 680 1960 390 550 1180 2020 920 2260 470 570 780 780 920 390 490 620 620 1560 Copper content Approx. (kg/km) 45 98 164 258 360 45 98 164 258 360 58 57 271 82 183 310 271 511 688 144 245 147 565 31 65 271 462 183 511 57 82 133 133 183 31 58 71 71 310

Number of elements

3 7 12 19 27 3 7 12 19 27 3 2 20 3 7 12 20 20 27 7 12 3 12 2 3 7 12 7 20 2 3 5 5 7 2 3 5 5 12

23

Marine, Oil & Gas BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Electrical values Type Unshielded pair 0,75 mm² Unshielded triple 0,75 mm² Unshielded pair 1,0 mm² Unshielded triple 1,0 mm² Unshielded pair 1,5 mm² Unshielded triple 1,5 mm² Unshielded pair 2,5 mm² Unshielded triple 2,5 mm² Capacitance, Inductance, approx. (nF/km) approx, (mH/km) 80 80 85 85 90 90 90 90 0,75 0,75 0,73 0,73 0,68 0,68 0,70 0,70 Resistance at 20° C, max. (Ohm/ km) 26,7 26,7 20,0 20,0 13,7 13,7 7,56 7,56 L/R ratio, (microH/Ohm) 14 14 18 18 24,8 24,8 46,3 46,3 Insulation resistance (Minimum MOhm x km) 940 940 840 840 730 730 620 620

Ordering information

Part number 840011 840012 840013 840014 840015 840031 840032 840033 840034 840035 840090 840111 840124 840132 840133 840134 840144 840171 840172 840173 840174 Description BFCU(C) 250V 3PAIR 0.75mm² BFCU(C) 250V 7PAIR 0.75mm² BFCU(C) 250V 12PAIR 0.75mm² BFCU(C) 250V 19PAIR 0.75mm² BFCU(C) 250V 27PAIR 0.75mm² BFCU(C) 250V 3PAIR 0.75mm² BFCU(C) 250V 7PAIR 0.75mm² BFCU(C) 250V 12PAIR 0.75mm² BFCU(C) 250V 19PAIR 0.75mm² BFCU(C) 250V 27PAIR 0.75mm² BFCU(C) 250V 3PAIR 1mm² BFCU(C) 250V 2PAIR 1.5mm² BFCU(C) 250V 20PAIR 0.75mm² BFCU(C) 250V 3PAIR 1.5mm² BFCU(C) 250V 7PAIR 1.5mm² BFCU(C) 250V 12PAIR 1.5mm² BFCU(C) 250V 20PAIR 0.75mm² BFCU(C) 250V 20PAIR 1.5mm² BFCU(C) 250V 27PAIR 1.5mm² BFCU(C) 250V 7TRIP 0.75mm² BFCU(C) 250V 12TRIP 0.75mm² Sheath Colour GREY GREY GREY GREY GREY BLUE BLUE BLUE BLUE BLUE BLUE BLUE GREY GREY GREY GREY BLUE GREY GREY GREY GREY Design standard BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 UKOOA Code GNH00 GNJ00 GNK00 GNM00 GLH00 GLJ00 GLK00 GLM00 GLH01 GNL00 GNH02 GNJ02 GNK02 GLL00 GNL02 GNM02 GNT00 GNU00

24

Marine, Oil & Gas BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Part number 840203 840205 840220 840255 840260 840261 840265 840266 840285 840286 840287 840288 840289 840317 840318 840319 840320 840321 Description BFCU(C) 250V 3PAIR 2.5mm² BFCU(C) 250V 12PAIR 2.5mm² BFCU(C) 250V 2PAIR 0.75mm² BFCU(C) 250V 3TRIP 0.75mm² BFCU(C) 250V 7TRIP 1.5mm² BFCU(C) 250V 12TRIP 1.5mm² BFCU(C) 250V 7PAIR 1.5mm² BFCU(C) 250V 20PAIR 1.5mm² BFCU(C) 250V 2PAIR 1.5mm² BFCU(C) 250V 3PAIR 1.5mm² BFCU(C) 250V 5PAIR 1.5mm² BFCU(C) 250V 5PAIR 1.5mm² BFCU(C) 250V 7PAIR 1.5mm² BFCU(C) 250V 2PAIR 0.75mm² BFCU(C) 250V 3PAIR 1mm² BFCU(C) 250V 5PAIR 0.75mm² BFCU(C) 250V 5PAIR 0.75mm² BFCU(C) 250V 12PAIR 1.5mm² Sheath Colour GREY GREY GREY GREY GREY GREY BLUE BLUE GREY BLUE GREY BLUE BLUE BLUE GREY GREY BLUE BLUE Design standard BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 UKOOA Code GNH03 GNK03 GNS00 GNT02 GNU02 GLJ02 GLL02 GLH02 GLJ02 GNH01 GLK02

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed 10 x D 8xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

25

Marine, Oil & Gas BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Fire resistant, Flame retardant halogen-free instrumentation cable. Enhanced oil-resistance.

BFCU(I) 250V

Operating temperature : 90°C Operating Voltage Application Fixed installation for instrumentation, communication, control and alarm systems in both EX­ and safe areas, emergency and critical systems where there is a requirement for fire resistant cables.. Enhanced MUD resistant version also available for use in areas exposed to mud and drilling / cleaning fluids, meeting the mud resistance requirement in NEK 606. Construction Code Letter Conductor Insulation B Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5) Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2) Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2 Colour coded cores twisted together to form a pair, triple or quad, which is individually screened with aluminium backed polyester tape with a tinned copper drain wire. Each pair, triple or quad is wrapped with polyester tape to prevent electrical contact with adjacent pairs, triples or quads. Individually shielded pairs, triples or quads are laid up in concentric layers and wrapped with a PETP tape. Pairs, triples, or quads are identified by numbers printed directly on the insulated conductors. Flame retardant and halogen-free thermoplastic EP-rubber based compound PET tape + rubberized Polyamide tape C Galvanized steel wire braid PET tape + rubberised Polyamide tape U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6 "metre mark" "year" "DRAKA" "BFCU(I)" "UKOOA code" "150/250V" "number of pair, triples or quads" "conductor size" "BS7917" "IEC60331-21" "IEC60332-3-22" (marking may differ on cable actually supplied) Grey or Blue Standards applied

BS7917/6883/UKOOA BS6360 class 2 or 5 BS7655 section 1.2 BS7655 section 2.6 IEC 60332-1 & 3-22 IEC60331-21 IEC60754-1,2 IEC 61034-1,2 Design Conductor Insulation Sheath Flame Retardant Fire Resistant Halogen Free Low Smoke

: 250V

Pair/Triple/Quad twisting / lay up

Inner covering Tape over inner covering Armour/screen Tape over armour/ screen Outer sheath Marking text Outer sheath colour

F

Core identification Pair Black--White, numbered 1-1, 2-2, 3-3 ...... Triple-- Black--White--Red, numbered 1-1-1, 2-2-2, 3-3-3 ...... Quad-- Black--White--Red--Blue, numbered 1-1-1-1, 2-2-2-2 ..... Each core is identified by contrasting numerals & words repeated along the whole length of the cable.

26

Marine, Oil & Gas BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Range and dimensions

Number of elements 1 1 1 3 7 12 1 1 1 3 7 12 1 1 1 1 1 1 1 7 1 1 7 7 2 1 1 1 7 20 1 3 3 3 Approx Thickness Thickness Approx Weight of No of Cross Conductor Insulation Diameter Diameter Inner Outer Overall Cable cores in section Diameter, Thickness Inner Braid Sheath, Sheath, Diameter Approx. element core, mm² mm mm Sheath, Wire, mm mm mm mm (Kg/Km) mm 2 4 3 3 3 3 2 4 3 3 3 3 2 4 2 4 3 2 2 2 3 3 2 2 2 4 4 3 2 2 4 2 2 2 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 1.5 1.5 1.5 1.5 1.5 1 1 0.75 1 1.5 1.5 1.5 1.5 1 1 1 0.75 0.75 2.5 0.75 1 0.75 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.6 1.6 1.6 1.6 1.6 1.3 1.3 1.15 1.3 1.6 1.6 1.6 1.6 1.3 1.3 1.3 1.15 1.15 2 1.15 1.3 1.15 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1 1.2 1 1.3 1.5 1.7 1 1.2 1 1.3 1.5 1.7 1.1 1.2 1.1 1.2 1.1 1 1 1.4 1.1 1.1 1.5 1.5 1.3 1.2 1.2 1.1 1.4 1.9 1.3 1.2 1.3 1.2 8 10 8.5 14.5 20 26.5 8 10 8.5 14.5 20 26.5 9.5 11 9.5 11 10 8.5 8.5 18 9 10 20.5 20.5 14 10 10 9 18 30 12 13.5 14 13.5 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 1.2 1.3 1.2 1.5 1.7 2 1.2 1.3 1.2 1.5 1.7 2 1.2 1.4 1.2 1.4 1.2 1.2 1.2 1.6 1.2 1.2 1.7 1.7 1.4 1.4 1.4 1.2 1.6 2.1 1.5 1.4 1.4 1.4 12 14 12.5 19 24.5 32.5 12 14 12.5 19 24.5 32.5 13 15.5 13 15.5 14 12.5 12.5 22.5 13 14 25 25 18.5 14.5 14.5 13 22.5 36.5 16.5 17.5 18.5 17.5 260 330 280 590 990 1640 245 330 280 590 990 1640 300 410 300 410 330 270 270 800 310 330 1030 1030 500 360 360 310 800 2040 500 480 520 480 Copper content Approx. (kg/km) 18 31 25 73 171 293 18 31 25 73 171 293 32 57 32 57 45 24 24 124 32 45 222 222 64 41 41 32 124 354 100 53 71 53

27

Marine, Oil & Gas BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Number of elements 12 20 5 3 5 20 1 5 5 12 2 2 2 2 2 2 3 3 3 3 12 12 20 Approx Thickness Thickness Approx Weight of No of Cross Conductor Insulation Diameter Diameter Inner Outer Overall Cable cores in section Diameter, Thickness Inner Braid Sheath, Sheath, Diameter Approx. element core, mm² mm mm Sheath, Wire, mm mm mm mm (Kg/Km) mm 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 2 2 2 2 2 4 2 2 2 2 2 2 3 3 3 3 3 2 2 2 2 2 0.75 0.75 1.5 0.75 1.5 1.5 1.5 1.5 0.75 0.75 1.5 0.75 0.75 1 1.5 1 1.5 1 1.5 1.5 1.5 1.5 1.15 1.15 1.6 1.15 1.6 1.6 1.6 1.6 1.15 1.15 1.6 1.15 1.15 1.3 1.6 1.3 1.6 1.3 1.6 1.6 1.6 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.9 1.3 1.3 1.3 2 1.2 1.4 1.4 1.6 1.2 1.3 1.2 1.3 1.3 1.3 1.3 1.4 1.3 1.3 1.8 1.8 2 30 16 15 16 34 11 18.5 18.5 24 12.5 14 12.5 14 14.5 15.5 15.5 16.5 14 15 27.5 27.5 34 0.45 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 2.1 1.5 1.5 1.5 2.3 1.4 1.6 1.6 1.8 1.4 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.4 1.5 2 2 2.3 36.5 20.5 19.5 20.5 41 15.5 23 23 29 17 18.5 17 18 19 20 20 21 18.5 19.5 33.5 33.5 41 2040 660 600 660 2640 410 840 840 1240 430 500 430 490 530 600 630 730 520 600 1750 1750 2640 Copper content Approx. (kg/km) 213 354 89 96 89 636 57 159 159 213 36 64 36 49 65 89 97 134 71 96 382 382 636

Electrical values Type Shielded pair 0,75 mm² Shielded triple 0,75 mm² Shielded quad 0,75 mm² Shielded pair 1 mm² Shielded triple 1 mm² Shielded quad 1 mm² Shielded pair 1,5 mm² Shielded triple 1,5 mm² Shielded quad 1,5 mm² Shielded pair 2,5 mm² Capacitance, Inductance, Resistance at 20° L/R ratio, (microH/ approx. (nF/km) approx (mH/km) C, max. (Ohm/km) Ohm) 90 90 60 100 100 70 110 110 80 120 0,75 0,75 0,91 0,73 0,73 0,95 0,68 0,68 0,99 0,70 26,7 26,7 26,7 20,0 20,0 20,0 13,7 13,7 13,7 7,56 14 14 14 18 18 18 24,8 24,8 24,8 46,3 Insulation resistance (Minimum MOhmx km) 940 940 940 840 840 840 730 730 730 620

28

Marine, Oil & Gas BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Ordering information

Part number 840009 840010 840017 840018 840019 840020 840029 840030 840037 840038 840039 840040 840041 840042 840045 840046 840087 840089 840123 840125 840127 840131 840138 840139 840140 840141 840142 840157 840175 840200 840202 840217 840218 840240 840253 840254 840267 840268 840271 840280 840281 840290 840291 Description BFCU(I) 250V 1PAIR 0.75mm² BFCU(I) 250V 1QUAD 0.75mm² BFCU(I) 250V 1TRIP 0.75mm² BFCU(I) 250V 3TRIP 0.75mm² BFCU(I) 250V 7TRIP 0.75mm² BFCU(I) 250V 12TRIP 0.75mm² BFCU(I) 250V 1PAIR 0.75mm² BFCU(I) 250V 1QUAD 0.75mm² BFCU(I) 250V 1TRIP 0.75mm² BFCU(I) 250V 3TRIP 0.75mm² BFCU(I) 250V 7TRIP 0.75mm² BFCU(I) 250V 12TRIP 0.75mm² BFCU(I) 250V 1PAIR 1.5mm² BFCU(I) 250V 1QUAD 1.5mm² BFCU(I) 250V 1PAIR 1.5mm² BFCU(I) 250V 1QUAD 1.5mm² BFCU(I) 250V 1TRIP 1.5mm² BFCU(I) 250V 1PAIR 1mm² BFCU(I) 250V 1PAIR 1mm² BFCU(I) 250V 7PAIR 0.75mm² BFCU(I) 250V 1TRIP 1mm² BFCU(I) 250V 1TRIP 1.5mm² BFCU(I) 250V 7PAIR 1.5mm² BFCU(I) 250V 7PAIR 1.5mm² BFCU(I) 250V 2PAIR 1.5mm² BFCU(I) 250V 1QUAD 1mm² BFCU(I) 250V 1QUAD 1mm² BFCU(I) 250V 1TRIP 1mm² BFCU(I) 250V 7PAIR 0.75mm² BFCU(I) 250V 20PAIR 0.75mm² BFCU(I) 250V 1QUAD 2.5mm² BFCU(I) 250V 3PAIR 0.75mm² BFCU(I) 250V 3PAIR 1mm² BFCU(I) 250V 3PAIR 0.75mm² BFCU(I) 250V 12PAIR 0.75mm² BFCU(I) 250V 20PAIR 0.75mm² BFCU(I) 250V 5PAIR 0.75mm² BFCU(I) 250V 3PAIR 1.5mm² BFCU(I) 250V 5PAIR 0.75mm² BFCU(I) 250V 20PAIR 1.5mm² BFCU(I) 250V 1QUAD 1.5mm² BFCU(I) 250V 5PAIR 1.5mm² BFCU(I) 250V 5PAIR 1.5mm² Sheath Colour GREY GREY GREY GREY GREY GREY BLUE BLUE BLUE BLUE BLUE BLUE GREY GREY BLUE BLUE BLUE BLUE GREY GREY GREY GREY GREY BLUE BLUE GREY BLUE BLUE BLUE GREY GREY BLUE GREY GREY GREY BLUE BLUE GREY GREY GREY GREY GREY BLUE Design standard BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 UKOOA Code GPF00 GPX00 GPR00 GPS00 GPT00 GPU00 GMF00 GMX00 GMR00 GMS00 GMT00 GMU00 GPF02 GPX02 GMF02 GMX02 GMR02 GMF01 GPF01 GPJ00 GPR01 GPR02 GPJ02 GMJ02 GPX01 GMX01 GMR01 GMJ00 GPL00 GPX03 GMH00 GPH01 GPH00 GPK00 GML00 GPH02 GPL02 GPX02 -

29

Marine, Oil & Gas BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Part number 840292 840314 840315 840316 840322 840323 840324 840325 840326 840327 840328 840329 840330 840331 Description BFCU(I) 250V 12PAIR 0.75mm² BFCU(I) 250V 2PAIR 0.75mm² BFCU(I) 250V 2PAIR 1.5mm² BFCU(I) 250V 2PAIR 0.75mm² BFCU(I) 250V 2TRIP 0.75mm² BFCU(I) 250V 2TRIP 1mm² BFCU(I) 250V 2TRIP 1.5mm² BFCU(I) 250V 3TRIP 1mm² BFCU(I) 250V 3TRIP 1.5mm² BFCU(I) 250V 3PAIR 1mm² BFCU(I) 250V 3PAIR 1.5mm² BFCU(I) 250V 12PAIR 1.5mm² BFCU(I) 250V 12PAIR 1.5mm² BFCU(I) 250V 20PAIR 1.5mm² Sheath Colour BLUE GREY GREY BLUE GREY GREY GREY GREY GREY BLUE BLUE GREY BLUE BLUE Design standard BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 7917 : 1999 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 BS 6883 : 1991 UKOOA Code GMK00 GPS01 GPS02 GMH01 GMH02 GPK02 GMK02 GML02

Installation recommendations

Minimum Bending Radius during Minimum Bending Radius Fixed Installation Installed 10 x D 8xD Maximum Tensile Load During Installation 50 N /mm² Minimum Installation Temperature -20°C

30

Marine, Oil & Gas UKOOA Cable coding

1st Character

Type Fire resistant, reduced halogen Fire resistant, low smoke and fume Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, low smoke and fume Flame retardant, reduced halogen Voltage 150/250V 150/250V 8.7/15kV 150/250V 150/250V 600/1000V Type Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, reduced halogen Flame retardant, low smoke and fume Fire resistant, reduced halogen Fire resistant, low smoke and fume Voltage 3.8/6.6kV 1.9/3.3kV 6.35/11kV 600/1000V 600/1000V 600/1000V

F G H J K L

M N P W X Y

2nd

Character

Basic construction Flame retardant Flame retardant Fire resistant Fire resistant Flame retardant Flame retardant Flame retardant Flame retardant Flame retardant Flame retardant Fire resistant Fire resistant Fire resistant Fire resistant Flame retardant Sheath colour Black (600/1000V), Red (HV) Black (600/1000V), Red (HV) Black (600/1000V) Black (600/1000V) Green/Yellow Black Light Blue Light Blue Grey Grey Light Blue Light Blue Grey Grey Orange Armour Bronze braid GSWB Bronze braid GSWB None None GSWB GSWB GSWB GSWB GSWB GSWB GSWB GSWB GSWB Screen

A B C D E F G H J K L M N P Y

Collective Individual Collective Individual Collective Individual Collective Individual Co-axial

3rd

1 2 3 4 7 A

Character

Single core 2 core 3 core 4 core 7 core 12 core B C D F H J 19 core 27 core 37 core 1 pair 3 pair 7 pair K L M N R S 12 pair 20 pair 27 pair 37 pair 1 triple 3 triple T U X Y Z 7 triple 12 triple 1 quad 3 quad 7 quad

4th & 5th Character

00 01 02 03 04 05 06 10 16 25 35 0.75 mm² 1.0 mm² 1.5 mm² 2.5 mm² 4 mm² 4 mm² 6 mm² 10 mm² 16 mm² 25 mm² 35 mm² Flexible (class 5) stranded tinned copper cores Flexible (class 5) stranded tinned copper cores Flexible (class 5) stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores 50 70 95 0A 0B 0C 0D 0E 0F 0G 0H 50 mm² 70 mm² 95 mm² 120 mm² 150 mm² 185 mm² 240 mm² 300 mm² 400 mm² 500 mm² 630 mm² Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores Stranded tinned copper cores

31

Marine, Oil & Gas Technical information

CONDUCTOR RESISTANCE

In accordance with BS 6360, class 2 (IEC 228,class2.) Nominal conductor No. of strands Maximum resistance per km ( ohm )

area ( mm² )

n x mmØ

20 °C

90 °C

1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

7 x 0,53 7 x 0,67 7 x 0,85 7 x 1,05 7 x 1,35 7 x 1,71 7 x 2,15 19 x 1,53 19 x 1,80 19 x 2,17 37 x 1,80 37 x 2,03 37 x 2,27 37 x 2,52 61 x 2,24 61 x 2,52

12,2 7,56 4,7 3,11 1,84 1,16 0,734 0,529 0,391 0,270 0,195 0,154 0,126 0,100 0,0762 0,0607

15,3 9,64 5,99 3,97 2,35 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774

In accordance with BS 6360, class 5-- Flexible tinned conductors for instrumentation and multicore cables Nominal conductor area ( mm² ) No. of strands n x mmØ Maximum resistance per km ( ohm ) 20 °C

90 °C

0,75 1,0 1,5

21 x 0,21 27 x 0,21 26 x 0,26

26,7 20,0 13,7

34,18 25,6 17,54

32

Marine, Oil & Gas Technical information

INSTALLATION RECOMMENDATIONS

The following installation recommendations are in accordance with British Standard 6883:1999, appendix B.

Installation temperature. Minimum recommended installation temperature for cables according to BS 6883 is -15°C.

Minimum cable bending radius. The cables specified in accordance with BS 6883 should not be bent to a radius smaller than that specified in the table below. Wherever possible, larger installation radii should be used. In the case of radial field cables the bend radii specified in the table below are applicable to bends made without the use of a former. Where the bend is carefully controlled using a former, the minimum radii can be reduced to 12D in the case of three-core cables and 15D for single-core cables.

Type of cable Screened multipair, triple and quad Multicore unarmoured (unbraided) 600/1000 V

Overall diameter Any 10 mm >10 mm to 25 mm >25 mm 25 mm >25 mm Any Any All single-core cables All three-core cables

Minimum bending radius 8xD 3xD 4xD 6xD 4xD 6xD 6xD 12xD 20xD

Multicore wire braided 600/1000 V Wire braided 1900/3300 V, 3300/3300 V Non-radial field wire braided 3800/6600 V, 6600/6600 V and 6350/11000 V Radial field wire braided 3800/6600 V, 6350/11000 V and 8700/15000 V cables

15xD

Where "D" is the overall diameter of the cable

33

Marine, Oil & Gas Technical information

Voltage test after installation Voltage tests after installation are not a requirement of this standard. If performed, the test should be made with direct current at the voltage in the table below after all terminating and jointing has been carried out but before before connection to the system. The voltage should be increased gradually to the full value and maintained continuously for 15 min between either: (a) (b) the conductor and the screen in case of screened cores; or each conductor and all the other conductors and braid, if any, in the case of unscreened cores. Voltage tests after installation Rated voltage U0 kV 0,15 0,6 1,9 3,3 3,8 6,35 6,6 8,7 Test voltage d.c kV 2,5 6 11 18 18 25 25 37

Installations pulling tension (Not specified in BS 6883) The cable pulling tension during installation can be estimated by means of the following formula: P = 5 kp x total cross section of conductors in the armoured cable. or P = 2,5 kp x total cross section of conductors in the unarmoured cable. Additional tension will be supplied from the braid and the insulation and sheathing compound.

Storage conditions (Not specified in BS 6883) Extended storage conditions on the site can be estimated to at least two years. The cableends always have to be sealed to stop ingress of moisture. One turn of the cable have to be scrapped if the cable end not have been sealed.

34

Marine, Oil & Gas Technical information

Voltage drop / RFCU 0.6/1kV

Conductor area, mm² Powerfactor 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0,2 5,440 3,373 2,108 1,407 0,843 0,541 0,352 0,260 0,199 0,145 0,112 0,093 0,081 0,069 0,059 0,052

90°C

50 Hz

R at 90°C X at 50Hz 0,7 19,05 11,82 7,39 4,93 2,96 1,90 1,24 0,92 0,71 0,52 0,40 0,33 0,29 0,25 0,21 0,19 0,8 21,78 13,51 8,45 5,65 3,39 2,18 1,42 1,06 0,81 0,60 0,46 0,39 0,34 0,29 0,25 0,22 0,9 24,52 15,21 9,52 6,36 3,83 2,46 1,61 1,20 0,93 0,68 0,53 0,45 0,39 0,34 0,29 0,26 1 27,30 16,96 10,64 7,12 4,30 2,78 1,84 1,38 1,07 0,80 0,63 0,54 0,47 0,42 0,36 0,33 15,6 9,64 5,99 3,97 2,35 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 0,103 0,096 0,096 0,090 0,084 0,080 0,079 0,076 0,076 0,075 0,073 0,072 0,072 0,072 0,072 0,071

Values of voltage drop for three phase circuit are tabulated with different power factors (cos"fi") Voltage drop, (V/A*km) 0,3 8,160 5,060 3,163 2,110 1,265 0,811 0,528 0,391 0,299 0,218 0,168 0,140 0,122 0,105 0,089 0,078 0,5 13,60 8,44 5,27 3,52 2,11 1,35 0,88 0,65 0,50 0,37 0,28 0,24 0,20 0,18 0,15 0,13

Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15

Voltage drop / RFCU 0.6/1kV

Conductor area, mm² Powerfactor 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0,2 5,447 3,380 2,115 1,413 0,849 0,546 0,357 0,266 0,205 0,151 0,117 0,098 0,086 0,074 0,064 0,057

90°C

60 Hz

R at 90°C X at 60Hz 0,7 19,08 11,84 7,42 4,96 2,98 1,92 1,26 0,94 0,73 0,54 0,42 0,35 0,31 0,27 0,23 0,21 0,8 21,81 13,54 8,48 5,67 3,42 2,20 1,45 1,08 0,84 0,62 0,49 0,41 0,36 0,32 0,27 0,25 0,9 24,56 15,25 9,56 6,40 3,86 2,49 1,64 1,23 0,96 0,71 0,56 0,47 0,42 0,37 0,32 0,29 1 27,35 17,01 10,69 7,17 4,35 2,82 1,88 1,42 1,11 0,84 0,67 0,57 0,52 0,46 0,40 0,37 15,6 9,64 5,99 3,97 2,35 1,48 0,936 0,675 0,499 0,344 0,249 0,196 0,161 0,128 0,0972 0,0774 0,123 0,115 0,115 0,108 0,101 0,096 0,095 0,092 0,092 0,091 0,088 0,086 0,087 0,086 0,086 0,086

Values of voltage drop for three phase circuit are tabulated with different power factors (cos"fi") Voltage drop, (V/A*km) 0,3 8,171 5,070 3,173 2,120 1,274 0,820 0,536 0,399 0,308 0,227 0,176 0,147 0,130 0,112 0,096 0,086 0,5 13,62 8,45 5,29 3,54 2,13 1,37 0,90 0,67 0,52 0,38 0,30 0,25 0,22 0,19 0,16 0,15

Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15

35

Marine, Oil & Gas Technical information

Voltage drop / BFCU 0.6/1kV 90°C 50 Hz

Values of voltage drop for three phase circuit are tabulated with different power factors (cos"fi") Conductor area, mm² Powerfactor 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 0.2 5.442 3.375 2.110 1.408 0.845 0.541 0.352 0.261 0.200 0.145 0.112 0.093 0.081 0.070 0.059 0.052 Voltage drop, (V/A*km) 0.3 8.163 5.062 3.165 2.112 1.268 0.812 0.529 0.392 0.300 0.218 0.169 0.140 0.122 0.105 0.089 0.078 0.5 13.608 8.440 5.278 3.523 2.115 1.356 0.884 0.655 0.503 0.366 0.284 0.236 0.206 0.177 0.149 0.132 0.7 19.059 11.824 7.397 4.940 2.967 1.905 1.244 0.923 0.710 0.518 0.403 0.336 0.293 0.253 0.215 0.191 0.8 21.789 13.520 8.461 5.652 3.398 2.182 1.427 1.061 0.817 0.597 0.465 0.389 0.340 0.295 0.250 0.223 0.9 24.527 15.223 9.531 6.371 3.834 2.466 1.616 1.204 0.929 0.682 0.534 0.447 0.393 0.341 0.291 0.260 1 27.314 16.972 10.647 7.132 4.310 2.787 1.842 1.381 1.077 0.800 0.635 0.538 0.477 0.420 0.364 0.330 15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.108 0.101 0.1 0.094 0.088 0.082 0.081 0.078 0.078 0.075 0.075 0.073 0.073 0.073 0.072 0.072 R at 90°C X at 50Hz

Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15

Voltage drop / BFCU 0.6/1kV

90°C

60 Hz

Values of voltage drop for three phase circuit are tabulated with different power factors (cos"fi") Conductor area, mm² Voltage drop, (V/A*km) R at 90°C X at 60Hz

Powerfactor 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

0.2 5.449 3.382 2.117 1.414 0.851 0.547 0.358 0.267 0.205 0.151 0.118 0.099 0.086 0.075 0.064 0.057

0.3 8.175 5.073 3.176 2.122 1.277 0.821 0.538 0.400 0.308 0.226 0.177 0.148 0.130 0.113 0.096 0.086

0.5 13.628 8.458 5.296 3.540 2.130 1.372 0.899 0.670 0.516 0.380 0.297 0.250 0.219 0.191 0.163 0.145

0.7 19.089 11.850 7.424 4.964 2.990 1.927 1.265 0.945 0.730 0.538 0.423 0.356 0.313 0.273 0.235 0.209

0.8 21.825 13.552 8.493 5.681 3.425 2.210 1.453 1.086 0.841 0.621 0.490 0.413 0.364 0.319 0.274 0.245

0.9 24.570 15.262 9.570 6.406 3.867 2.499 1.647 1.235 0.958 0.711 0.563 0.476 0.422 0.370 0.320 0.287

1 27.374 17.026 10.701 7.181 4.356 2.833 1.885 1.425 1.117 0.841 0.676 0.579 0.518 0.461 0.405 0.368 15.6 9.64 5.99 3.97 2.35 1.48 0.936 0.675 0.499 0.344 0.249 0.196 0.161 0.128 0.0972 0.0774 0.13 0.121 0.12 0.112 0.105 0.099 0.097 0.094 0.093 0.09 0.09 0.088 0.088 0.088 0.087 0.086

Values of voltage drop for single phase circuit may be obtained by multiplying with a correction factor: 1.15

36

Marine, Oil & Gas Technical information

CODE DESIGNATION

EPR MGT EPR Ethylene Propylene Rubber insulation According to BS 7655 (section 1.2) , type GP4 Mica Glass Tape Inner covering, flame retardant halogen-free EP-rubber based compound Galvanized Steel wire Braid Phosphore Bronze Wire Braid Flame retardant, halogen-free, enhanced oil-resisting and mud resistant thermoset compound In accordance with BS 7655 Section 2.6 type SW4

GSWB PBWB LSF -

Materials

1.Letter: Insulation B R

2.Letter: Bedding/ Sheath

3.Letter: Braid/ Armour

4.Letter: Outher Sheath

Mica/EPR- insulation EPR- insulation EPR- based bedding Galvanized Steel Wire Braid Phosphor bronze wire LSF

F C P U U

Additional abbreviation for instrumentation cables: Collective screen cable............................ (c) Individual pair/triple screened cable........... (i)

37

Marine, Oil & Gas

Other catalogues available on request: NEK606 Offshore Cables

RFOU 0.6/1kv BFOU 0.6/1kv RFOU 6/10(12)kv RFOU 8.7/15kv RFOU 12/20(24)kv RFOU(C) & RFOU(I) 250v BFOU(C) & BFOU(I) 250v UX Earth RU 0.6/1kv BU 0.6/1kv QFCI Fire Resistant Armoured Fibre Optics

Bostrig Type P IEEE Rig Cables

Power Control Signal Armoured & Unarmoured Marine Fibre Optics VFD Type P

Bostmarine Cables

Power Control Signal

Shipline Marine Cables

TI 0.6/1kv TI(C) 0.6/1kv TXOI 0.6/1kv TXOI 250v BI 0.6/1kv BI(C) 250v BI(I) 250v BXOI 0.6/1kv BXOI 250v BXOI(I) 250v TFOI 6/10(12)kv

Shipline Plus Marine Cables

HUSK--TFXI 0.6/1kv HUSO--TIOI 0.6/1kv HUCOM TIOI(C) 250v

Suite 112, First Floor, Naroon Bldg. 395 Dr Bahonar (Niavaran) ave. After Kamranieh Intersection Tehran - IRAN Tel: +98 (21) 2610 4196, 7 Fax: + 98 (21) 2610 4041 Web: www.almascable.com email: [email protected]

BS/UKOOA CAT 07/2008

Information

41 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

712715


You might also be interested in

BETA
14FZ.fm.save
DIVIDERS - SESCO (Page 26)
Anixter Wire & Cable Technical Information Handbook
britStand.set