HeATing inpuT: 60,000­100,000 bTu/H

Two-STAge, VAriAble SpeeD gAS FurnACe 80% AFue

AMVC8/ADVC8

Standard Features

· MillionAir® stainless-steel, dualdiameter tubular heat exchanger · Two-stage gas valve operates on twostage or single-stage thermostats · ComfortNetTM Communications System compatible · Efficientandquietvariable-speedECM circulator motor gently ramps up or down according to heating or cooling demand · SureStart® Silicon Nitride igniter designed for long igniter life · Furnace control board with self-diagnostics and provisions forelectronicaircleanerand120-voltor24-volthumidifiers · Low constant fan speed circulates air throughout the home · Quiet, two-speed induced draft blower · California Low NOx emissions-compliant models available

Cabinet Features

· Fully insulated, heavy-gauge steel cabinet withdurablebaked-enamelfinish · Designed for multi-position installation: upflow,horizontalleftorright · Removable bottom for side- or bottom-return applications · Convenient left or right connection for gas/electric service · Coilandfurnacefitflushformostinstallations

Contents

Nomenclature ....................................... 2 ProductSpecifications .......................... 3 Dimensions ........................................... 4 AirflowData .......................................... 6 Wiring Diagram ...................................11 Accessories .......................................... 12

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Unit Replacement Limited Warranty and Lifetime Heat Exchanger Limited Warranty (in both cases, good for as long as you own your home) plus the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

SS-AMVC8

www.amana-hac.com

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

7/12

Supersedes 2/12

Product SPecificationS

noMenClATure

A 1 M 2 V 3 C 4 8 5 060 6,7,8 4 9 C 10 * 11 * 12 * 13

Brand A Amana® Brand

Revisions Major and Minor Revisions NOx N X Natural Gas Low NOx Cabinet Width A 14" B 17½" C 21" D 24½" Maximum CFM @ 0.5" ESP 3 1200 4 1600 5 2000 MBTU/h

Airflow Direc5on C Downflow/Horizontal D Dedicated Downflow H High Airflow K Dedicated Upflow M Upflow/Horizontal Descrip5on/Motor V Two-Stage/Variable-speed H Two-Stage/MulS-speed S Single-Stage/MulS-speed E Two-Stage/High-Efficiency SystemType C ComfortNetTM CommunicaSng System AFUE 95 95% 9 90%+ 040: 40,000 060: 60,000 080: 80,000

8 80%

100: 100,000 120: 120,000

2

www.amana-hac.com

SS-AMVC8

Product SPecificationS

SpeCiFiCATionS

AMVC8 0604B*B Heating Capacity High Fire Input (BTU/h)¹ High Fire Output (BTU/h)¹ (below) Natuarl Gas LP Gas Low Fire Input (BTU/h)¹ Low Fire Output (BTU/h)¹ (below) Natuarl Gas LP Gas AFUE2 Available AC @ 0.5" ESP Temperature Rise Range (° F) Circulator Blower Size (D x W) Horsepower - RPM Speed Vent Diameter² No. of Burners Disposable Filter Size (in²) Electrical Data Min. Circuit Ampacity³ Max. Overcurrent Device (amps) Ship Weight (lbs)

1

AMVC8 0805C*B 80,000 64,000 64,000 56,000 44,800 44,800 80 2.0 - 5.0 20 - 50 10" x 10" ¾ Variable 4" 4 813 11.7 15 178

AMVC8 1005C*B 100,000 80,000 80,000 70,000 56,000 56,000 80 2.0 - 5.0 25 - 55 10" x 10" ¾ Variable 4" 5 1,016 11.7 15 194

ADVC8 0603B*B 60,000 48,000 48,000 42,000 33,600 33,600 80 1.5 - 3.0 30-60 10" x 8" ¾ Variable 4" 3 474 12.1 15 155

ADVC8 0805C*B 80,000 64,000 64,000 56,000 44,800 44,800 80 2.0 - 5.0 35 - 65 10" x 10" ¾ Variable 4" 4 569 12.1 15 177

ADVC8 1005C*B 100,000 80,000 80,000 70,000 56,000 56,000 80 2.0 - 5.0 35-65 10" x 10" ¾ Variable 4" 5 711 12.1 15 193

60,000 48,000 48,000 42,000 33,600 33,600 80 1.5 - 4.0 20 - 50 10" x 8" ¾ Variable 4" 3 610 11.7 15 152

2 3

4

Natural Gas BTU/h; for altitudes above from 0' to 4,500' above sea level, reduce input rating 4% for each 1,000' above 4,500' altitude. Low-fire rate is 70% of high-fire rate. DOE AFUE based upon Isolated Combustion System (ICS) Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes · All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. · Gas Service Connection ½" FPT · Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

SS-AMVC8

www.amana-hac.com

3

Product SPecificationS

AMVC8 PRODUCT DIMENSIONS DiMenSionS

Alt. Gas Inlet Alt. Gas Inlet

AMVC8/GMVC8_____X*

1/

19½

19½

33³/ 27/ High-Voltage Inlet High Voltage Inlet

Low Voltage Low-Voltage Inlet

Gas Inlet Alt. Gas Inlet

20 13¼

23/

Alt. High Voltage High Voltage

Alt. LowVoltage Low Voltage

23¾ 28

DiMenSionS

Model AMVC80604B*B AMVC80805C*B AMVC81005C*B A 17½" 21" 21" B 16"

MODELS A B

19½" AMVC80704BX** GMVC80704BX** 19½"

AMVC80905CX** AMVC81155CX** GMVC80905CX** GMVC81155CX**

17-1/2

16

21

19-1/2

MiniMuM CleArAnCeS To CoMbuSTible MATeriAlS

Sides 1 Rear 0 Front ¹ 3

All dimensions are in inches.

Vent ² SW 6 B 1

Top 1

Approved for line contact in the horizontal position. ¹ 24" clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements.

8

4

www.amana-hac.com

SS-AMVC8

Product SPecificationS

ADVC8 DiMenSionS

DiMenSionS

Model ADVC80603B*B ADVC80805C*B ADVC81005C*B A 17½" 21" 21" B 16" 19½" 19½"

MiniMuM CleArAnCeS To CoMbuSTible MATeriAlS

Sides 1 Rear 0 Front ¹ 3 Vent ² SW 6 B 1 Top 1

Approved for line contact in the horizontal position. ¹ 24" clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the venting tables outlined in the Installation Manual for additional venting requirements.

AuTo-CoMForT MoDe

During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then ramps to 85% of the full coolingdemandairflowandoperatesthereforapproximately7½minutes.Themotorthenstepsuptothefulldemandairflow.This modespendsahalfminuteat50%airflowOFFdelay.

OFF

85% CFM 50% CFM ½min ½min

100% CFM

50% CFM

OFF

½min

Cooling Demand

SS-AMVC8

www.amana-hac.com

5

Product SPecificationS

AMVC8 AirFlow DATA

AMVC80604B*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% A Normal Plus 5% Plus 10% Minus 10% Minus 5% B Normal Plus 5% Plus 10% Minus 10% Minus 5% C Normal Plus 5% Plus 10% Minus 10% Minus 5% D Normal Plus 5% Plus 10% High-Stage CFM 540 570 600 630 660 720 760 800 840 880 990 1,045 1,100 1,155 1,210 1,260 1,330 1,400 1,470 1,540 Low-Stage CFM 351 371 390 410 429 468 494 520 546 572 644 679 715 751 787 819 865 910 956 1,001 D C B A Tap AMVC80604B*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20° - 50°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 1,125 1,188 1250 1,313 1,375 1,215 1,283 1,350 1,418 1,485 1,305 1,378 1,450 1,523 1,595 1,395 1,473 1,550 1,628 1,705 Low-Stage CFM 788 831 875 919 963 851 898 945 992 1,040 914 964 1,015 1,066 1,117 977 1,031 1,085 1,139 1,194 Rise 46 43 41 39 38 43 40 38 36 35 40 38 36 34 33 37 35 33 31 30

AMVC80805C*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% A Normal Plus 5% Plus 10% Minus 10% Minus 5% B Normal Plus 5% Plus 10% Minus 10% Minus 5% C Normal Plus 5% Plus 10% Minus 10% Minus 5% D Normal Plus 5% Plus 10% See Notes on following page. High-Stage CFM 720 760 800 840 880 990 1,045 1,100 1,155 1,210 1,260 1,330 1,400 1,470 1,540 1,620 1,710 1,800 1,890 1,980 Low-Stage CFM 468 494 520 546 572 644 679 715 751 787 819 865 910 956 1,001 1,053 1,112 1,170 1,229 1,287 D C B A Tap

AMVC80805C*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 20° - 50°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 1,350 1,425 1,500 1,575 1,650 1,440 1,520 1,600 1,680 1,760 1,530 1,615 1,700 1,785 1,870 1,620 1,710 1,800 1,890 1,980 Low-Stage CFM 945 998 1,050 1,103 1,155 1,008 1,064 1,120 1,176 1,232 1,071 1,131 1,190 1,250 1,309 1,134 1,197 1,260 1,323 1,386 Rise 49 46 44 42 40 46 44 42 40 38 44 41 39 37 36 41 39 37 35 34

6

www.amana-hac.com

SS-AMVC8

Product SPecificationS

AMVC8 AirFlow DATA (ConT.)

AMVC81005C*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 720 760 800 840 880 990 1,045 1,100 1,155 1,210 1,260 1,330 1,400 1,470 1,540 1,620 1,710 1,800 1,890 1,980 Low-Stage CFM 468 494 520 546 572 644 679 715 751 787 819 865 910 956 1,001 1,053 1,112 1,170 1,229 1,287 Tap AMVC81005C*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 25° - 55°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 1,553 1,639 1,725 1,811 1,898 1,575 1,663 1,750 1,838 1,925 1,598 1,686 1,775 1,864 1,953 1,620 1,710 1,800 1,890 1,980 Low-Stage CFM 1,089 1,150 1,210 1,271 1,331 1,103 1,164 1,225 1,286 1,348 1,121 1,183 1,245 1,307 1,370 1,134 1,197 1,260 1,323 1,386 Rise 55 52 49 47 45 54 51 49 46 44 53 50 48 46 44 53 50 47 45 43

A

A

B

B

C

C

D

D

Notes · These charts are for furnaces installed at 0' - 4,500'. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. · The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. · Do not operate above .5" w.c. ESP in heating mode. · Propane gas installations will have a high-stage rise approximately 4°F lower than shown in the tables.

SS-AMVC8

www.amana-hac.com

7

Product SPecificationS

ADVC8 AirFlow DATA

ADVC80603B*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% A Normal Plus 5% Plus 10% Minus 10% Minus 5% B Normal Plus 5% Plus 10% Minus 10% Minus 5% C Normal Plus 5% Plus 10% Minus 10% Minus 5% D Normal Plus 5% Plus 10% High-Stage CFM 540 570 600 627 660 720 760 800 836 880 900 950 1,000 1,045 1,100 1,080 1,140 1,200 1,254 1,320 Low-Stage CFM 351 371 390 408 429 468 494 520 543 572 585 618 650 679 715 702 741 780 815 858 D C B A Tap ADVC80603B*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 30° - 60°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 945 998 1,050 1,097 1,155 1,035 1,093 1,150 1,202 1,265 1,125 1,188 1,250 1,306 1,375 1,215 1,283 1,350 1,411 1,485 Low-Stage CFM 660 698 735 770 810 725 765 805 841 885 790 831 875 912 960 850 898 945 988 1,040 Rise (°F) 55 52 49 47 45 50 47 45 43 41 46 43 41 39 38 43 40 38 36 35

ADVC80805C*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% A Normal Plus 5% Plus 10% Minus 10% Minus 5% B Normal Plus 5% Plus 10% Minus 10% Minus 5% C Normal Plus 5% Plus 10% Minus 10% Minus 5% D Normal Plus 5% Plus 10% See Notes on following page. High-Stage CFM 720 760 800 836 880 990 1,045 1,100 1,150 1,210 1,260 1,330 1,400 1,463 1,540 1,620 1,710 1,800 1,881 1,980 Low-Stage CFM 468 494 520 543 572 644 679 715 748 787 819 865 910 951 1,001 1,053 1,112 1,170 1,223 1,287 D C B A Tap

ADVC80805C*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 35° - 65°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 1,215 1,283 1,350 1,411 1,485 1,305 1,378 1,450 1,515 1,595 1,395 1,473 1,550 1,620 1,705 1,485 1,568 1,650 1,724 1,815 Low-Stage CFM 850 898 945 988 1,040 915 964 1,015 1,059 1,115 975 1,031 1,085 1,135 1,195 1,040 1,097 1,155 1,207 1,270 Rise (°F) 55 52 49 47 45 51 48 46 44 42 48 45 43 41 39 45 42 40 38 37

8

www.amana-hac.com

SS-AMVC8

Product SPecificationS

ADVC8 AirFlow DATA (ConT.)

ADVC81005C*B Cooling Speeds (@ .1" - .8" w.c. ESP) Tap Adjust Minus 10% Minus 5% A Normal Plus 5% Plus 10% Minus 10% Minus 5% B Normal Plus 5% Plus 10% Minus 10% Minus 5% C Normal Plus 5% Plus 10% Minus 10% Minus 5% D Normal Plus 5% Plus 10% High-Stage CFM 765 808 850 888 935 1,035 1,093 1,150 1,202 1,265 1,305 1,378 1,450 1,515 1,595 1,665 1,758 1,850 1,900 2000 Low-Stage CFM 497 525 553 578 608 673 711 748 781 822 848 896 943 985 1,037 1,082 1,143 1,203 1,257 1,323 D C B A Tap ADVC81005C*B Heating Speeds (@ .1" - .5" w.c. ESP; Rise Range: 35° - 65°F) Adjust Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% Minus 10% Minus 5% Normal Plus 5% Plus 10% High-Stage CFM 1,395 1,473 1,550 1,620 1,705 1,485 1,568 1,650 1,188 1,815 1,575 1,188 1,750 1,188 1,925 1,620 1,188 1,800 1,188 1,980 Low-Stage CFM 975 1,031 1,085 1,135 1,195 1,040 1,188 1,155 1,188 1,270 1,105 1,188 1,225 1,188 1,350 1,135 1,188 1,260 1,188 1,385 Rise (°F) 61 58 55 52 50 57 54 52 49 47 54 51 49 46 44 53 50 47 45 43

Notes · These charts are for furnaces installed at 0' - 4,500'. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower. · The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate. · Do not operate above .5" w.c. ESP in heating mode. · Propane gas installations will have a high-stage rise approximately 4°F lower than shown in the tables.

SS-AMVC8

www.amana-hac.com

9

Product SPecificationS

TeMperATure riSe rAnge CHArT

TEMPERATURERise Temperature RISE

10

BTU OUTPUT vs TEMPERATURE Rise Chart BTU Output Vs. Temperature RISE CHART

100

600 CFM 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM

90

80

70

60

50

www.amana-hac.com

40

30

Formulas FORMULAS

BTU OUTPUT ==CFMxx1.08 x Rise BTU/h Output CFM 1.08 x RISE BTU OUTPUT RISE = = BTU/H Output ÷ CFM Rise 1.08

CFM x 1.08

20

10 50 60 70 80 90 100 OUTPUT BTU/h x 1,000 Output BTU/HR x 1000 110 120 130 140 150

30

40

SS-AMVC8

Product SPecificationS

wiring DiAgrAM

GND ID BLOWER TWO-STAGE PRESSURE SWITCH ASSEMBLY HOT SURFACE IGNITER

2 1

L

TO 115 VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE

YL

YL BR

JUNCTION BOX

RD

WH

LOW FIRE PRESSURE

YL

C NO

24V HUM.

C NO

BK WH

DISCONNECT N

SWITCH 2 CIRCUIT CONNECTOR TWO STAGE GAS VALVE (HONEY WELL)

WARNING:DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.

BL

YL

HIGH FIRE PRESSURE SWITCH

TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE

SENSOR

C HI PM

3 2 1

BL

BR AUTO RESET PRIMARY LIMIT CONTROL

DISCONNECT

MANUAL RESET ROLLOUT LIMIT CONTROLS

PU

PU

RD

DOOR SWITCH JUNCTION BOX INDUCTOR COIL 70kBTU,90kBTU, 115kBTU MODELS ONLY

PU

3 2 1

WH RD BK GND

INDUCED DRAFT BLOWER

INDOOR AIR CIRCULATOR BLWR GND SEE NOTE 6 HUMIDIFIER HUMIDIFIER ELECTRONIC AIR CLEANER NEUTRAL NEUTRAL NEUTRAL

HUM-IN LINE

BURNER COMPARTMENT BLOWER COMPARTMENT

AUTO RESET AUXILIARY LIMIT CONTROL

PU

HUM-OUT HUM EAC IND HI

NEUTRAL

5

4 3 2 1

ID BLWR IGN IND LO HOT SURFACE IGNITER

NEUTRAL NEUTRAL

FS

LINE

FS

LINE

4 CIRCUIT MOTOR CONNECTOR

FLAME SENSOR 115 VAC

NEUTRAL 40 VA TRANSFORMER

COOL AF

4 3 2 1

TRIM % COOL PRFL HEAT AF

DIP SWITCHES

BL RD

24V THERMOSTAT CONNECTIONS

FUSE 3 A

R TO +VDC Y1

TH (4)

24 VAC AUTO RESET AUXILIARY LIMIT CONTROLS HLO (10)

AUTO RESET PRIMARY LIMIT CONTROL

BK

13 10 7

14 11 8 5 2

15 12 9 6 3

DEHUM ENABLE TRIM ENABLE CONT FAN HEAT OFF DLY T-STAT SEE NOTE 5

24 VAC 115 VAC

PSO (7)

W1

PS1 (2)

24V HUM.

C

LOW FIRE PRESS. SWITCH

NO

PS2 (12)

1

DIAGNOSTIC LED'S

DEHUM

TRANSFORMER

40 VA

Y2 G O

DEHUM

TO MICRO

NO C

MANUAL RESET ROLLOUT LIMIT CONTROLS

HIGH FIRE PRESS. SWTICH

FUSE

24 V THERMOSTAT CONNECTIONS

MVL (13) MVH (14)

PM HI C

GAS VALVE

MVC (8) GND (5)

ECM MTR HARNESS

RD

BL GY BK

5 4 3 2 1

BK GR PK

BK WH

GND

BK

BK

TO R BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN)

2

3

TR (11) GND (4) + VDC (1) RX (2) TO MICRO TX (3) AUX

INTEGRATED CONTROL MODULE

GND

INDOOR AIR CIRCULATOR BLWR

CIRCULATOR BLOWER

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF

INDUCTOR COIL 70kBTU,90kBTU, 115kBTU MODELS ONLY

HUMIDIFIER

AT LEAST 105 $ C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)

6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING HEAT CALL (COMMUNICATING OR LEGACY MODES). USE HUM-IN AND HUM-OUT TERMINALS TO RUN HUMIDIFIER DURING HEAT CALL ( COMMUNICATING MODE OR LEGACY MODE) OR INDEPENDENTLY FROM HEAT CALL (COMMUNICATING MODE ONLY - SETUP IS DONE WITHIN COMMUNICATING THERMOSTAT)

COLOR CODES: PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK

LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION

EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE

0140F01168-A

SS-AMVC8

www.amana-hac.com

Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.

WH

C

1

4

11

24 V 3A

WH

HLI (1)

Warning

4

W2

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

WH

INTEGRATED CONTROL MODULE

BK WH

YL

FLAME

WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.

L

GND

N

CHASSIS GROUND

INTEGRATED CONTROL MODULE

OR

GN

BK RD WH

HUMOUT EAC

HUMIN

HUM

5 CIRCUIT CONNECTOR

BK

BK

OR

BL YL WH

GN

BL BR RD YL RD RD YL

TWO-STAGE INTEGRATED CONTROL MODULE

PU

1

W2

W1

Y2

Y1

C

G

R

2

O

24V HUM.

Product SPecificationS

ACCeSSorieS

Model LPM-06 AFE18-60A ASAS AMU

¹

Description LP Conversion Kit (Springs & Orifice) ¹ Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat) Electronic Air Cleaners (* = -10, -11, -12 or -18) Media Air Cleaners (* = 1620, 2020, 1625 or 2025)

White-Rodgers and Honeywell valves

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2013 · Goodman Company, L.P. · Houston, Texas · Printed in the USA.

12

www.amana-hac.com

SS-AMVC8