Read American Spec Sheets 2008 new temp.indd text version

Residential Gas PowerFlex® Power Direct Vent

The industry's first flammable vapor ignition resistant (FVIR) approved power vented gas water heater is better than ever. These highly efficient water heaters have a .66 Energy Factor, with a smaller footprint allowing installation in an approved drain pan.

· Direct Vent

Takes all combustion air from outside the home and vents all exhaust gases outside the home. Works great for homes with negative pressure or high efficiency homes with tight construction.

6-Year Limited Tank/Parts Warranty*

· Power Venting Made Simple

Thru-the-Wall or Thru-the-Roof power venting using either 2" or 3" PVC, ABS or CPVC vent pipe.

· Self-Diagnostic Control System

Microprocessor control provides diagnostic codes in case of system malfunction, and directs burner ignition to extend the ignitor's life.

· Quiet and Efficient Blower

Factory installed 6-foot power cord with standard 3-prong male connector provided. Electrical requirements; 110/120 VAC power source, less than 5 amp draw.

· Aluminized Steel Multiport Burner

For even flame distribution, quiet operation and high-efficiency combustion. Low NOx certified.

· Combination Thermostat/ECO

Utilizes an intermittent ignition gas valve (no standing pilot) with thermistor temperature sensor and built-in high temperature cut off.

· Other Features

- 3/4" Water Connections - Factory Installed T&P Valve - 1/2" Gas Connections - Fused Ceramic Shield Tank Lining - Heavy-Duty Anode Rod - 2" Non-CFC Foam Insulation - Child-Resistant Drain Valve - High Temperature Dip Tube - Factory-Installed Heat Traps - Condensate Coupler Included - Side Space Heating Connections on 50T60 Models

· Code Approvals

CSA International certified, CEC and 1987 NAECA current requirements. All models are certified at 300 PSI test pressure and 150 PSI working pressure. Meets California and Texas Code Approvals for Low NOx emissions.

*For complete warranty information consult the written warranty of American Water Heaters found at www.americanwaterheater.com, or call (800) 999-9515.

Copyright© by American® Water Heaters 2008. All rights reserved. Copyright© by American® Water Heaters 2008. All rights reserved.

NRGSS00508

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.

Residential Gas PowerFlex® Power Direct Vent

BLOWER

AIR INLET

40-GAL. = 26" 50-GAL. = 27" EXHAUST OUTLET

INPUT BTU PER HR. MODEL NUMBER PDVG62-40T42-NV PDVG62-50T42-NV PDVG62-50T60-NV GAL. CAP. 40 50 50 NAT. 42,000 42,000 60,000 LP 42,000 42,000 50,000

GPH RECOVERY 90° RISE NAT. 42.6 42.6 60.8 LP 42.6 42.6 50.7 VENT DIAM. 2 or 3 2 or 3 3 E.F. 0.66 0.66 0.66

HEIGHT JACKET DIAM. A 20 22 22 TOP OF VENT B 66-7/8 65-5/8 65-5/8 TOP OF HEATER C 58-5/8 57-7/16 57-7/16 SIDE T&P D 51-1/2 51 51 APPROX. SHIP WEIGHT 170 207 207

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Dimensions on all charts shown in inches. Top inlet and outlet are on 8" centers. 50T60 model includes side located space heating water connections. For propane, substitute "P" for "N" in the model number.

Specification

Sealed Combustion power vent gas water heater(s) model _____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ____-year tank warranty and a ____-year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of _____gallons and shall have a rated input of __________BTU's, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 & CSA 4.1 standard. Heaters must be flammable vapor ignition resistant approved. Heaters shall meet or exceed the requirement of the Federal "National Appliance Energy Conservation Act of 1987" -- current requirements and shall comply with ASHRAE Standard 90.1-1999. The interior of the storage tank shall be lined with a Fused Ceramic Shield Lining, fused to the tank at 1600°F, forming a corrosion-resistant lining, polymer linings are not acceptable. Each tank shall be furnished with an internal anode for cathodic protection. The unit must be equipped with a combination gas control thermostat (utilizing a thermistor sensor) and non-reset type ECO. A corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted and insulated with a non-CFC foam to reduce standby heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure. Power vent blower must be 120 VAC. Unit must be capable of venting _________feet using PVC, ABS or CPVC pipe.

Distributed By:

Order Entry and Sales 500 Princeton Road (FEDEX, UPS) Johnson City, TN 37601-2030 P.O. Box 4808 (Mailing) Johnson City, TN 37602-4808 (800) 937-1037 FAX (800) 581-7224

NRGSS00508

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.

Warranty and Service 500 Princeton Road (FEDEX, UPS) Johnson City, TN 37601-2030 P.O. Box 1597 (Mailing) Johnson City, TN 37605-1597 (800) 999-9515 FAX (800) 999-5210

Information

American Spec Sheets 2008 new temp.indd

2 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

149598