ProCash 2150xe

Short installation manual

SPECIFIKATIONS

Physical Security

This ATM meets the following Security standards EN 60950, UL60950 and meets the attack test per UL 291-15, CSA C22.2-60950, IEC 60950. The safe door has a relocking feature. The controlling of safe door is by keys, combination lock with keys or optional electronic lock.

ProCash 2150xe

SPECIFIKATIONS

Dimensions and Weight of Unit with installation frame

Height Recommended Installation Height Width Depth Depth with fascia frame (Wodden Support Table)

ProCash 2150xe

1391 mm (54.76 ") NA 790 mm (31.1") 1213 mm (47.76") NA UL 291 Business NA NA NA NA NA NA UL 291 907 kg (1999.94 lb) CEN III CEN IV

Alarm Protection

The UL - listed safe is equipped with a basic alarm sensor package. The package includes a safe cabinet door open switch. Optional seismic sensor.

Power Requirements

This ATM meets the following EMC standards EN 55 022 class B, EN55024, EN 50082-1, EN 50082-2, EN61000-3-2, EN61000-3-3, FCC CFR 47, part 15 subpart B class A, ICES-003 (CSA 108.8) and BSMIStandard CNS 13438 class B. The CE symbol indicates that the product complies with the following EU directives. EMC 89/336/ECC, 91/263/ECC, 92/31/ECC and 93/68/ECC and on Low voltage directive / security 73/23/ECC and 93/68/ECC. The ATM requires a single-phase three-wire unswitched power outlet. Wiring to the ATM must use a third-wired earth ground (conduit ground is not acceptable). The power supplied must be as specified below: 110 - 120 / 220 - 240 VAC (- 10 to + 6 %) at 50/60 Hz (+/- 1%), single phase

with Safe

Weight Surface Load Foot print / TN Operation and Maintenance Area (Front Load) Operation and Maintenance Area (Rear Load) Fan capacity

1087 kg (2396.84 lb) 1057 kg (2330.69 lb)

15.8kN/m²(2.3lb/in²) 20.1kN/m²(3.0lb/in²) 19.6kN/m²(2.9lb/in²) 0,6 m² (6.46 ft²) NA 2.3 m² (24.75 ft²) 0,6 m² (6.46 ft²) NA 2.3 m² (24.75 ft²) 0,6 m² (6.46 ft²) NA 2.3 m² (24.75 ft²)

Network structure

Each ATM must have a dedicated outlet/circuit. Power to the ATM may be a branch or dedicated service and must be protected by a safety quick-disconnect device the break line voltage (such a circuit breaker at the electrical service panel). The quick disconnect device (or circuit breaker) must turn off the line voltage at the amperage specified below. Fuse for the Device 110-120 VAC service, disconnect at 10 amps or Fuse 220-240- VAC service, disconnect at 10 amps Degree of Protection (EN 60529) Outdoors / Indoors Other electronic devices sharing power on a common branch circuit must conform to the same conducted interference standards as the ATM.

60m³/h(2118.6 ft³/h) 60m³/h(2118.6 ft³/h) 60m³/h(2118.6 ft³/h)

Fore more Details regarding Installation not covered in this document we refer to Reference Installation Guide with order no.: 01750058423

IP 54 / IP 20

GENERAL SPECIFIKATIONS

Single Cable Run Constrains

Power Usage for ATM without UPS

Rated Current Consumption (Maximum Operation) 110-120 VAC / 220-240 VAC Apparent Power Consumption (Maximum Operation) 110-120 VAC / 220-240 VAC Real Output 110-120 VAC / 220-240 VAC Power factor 110-120 VAC / 220-240 VAC Protection Class Leakage Current (Maximum) 110-120 VAC / 220-240 VAC Apparent Power Consumption open circuit 3.2 / 1.65 A 340 / 320 VA 1010 / 970 BTU/h 0.93 / 0.88 I 1.2 / 1.2 mA NA 4.2 / 2.6 A 455 / 435 VA 1365 / 1314 BTU/h NA I 6.4 / 6.4 mA NA 4.5 / 2.2 A 545 / 500 VA 1860 / 1707 BTU/h 3.2 / 1.65 A 340 / 320 VA 296 / 284 W 0.93 / 0.88 I 1.2 / 1.2 mA NA 4.2 / 2.6 A 455 / 435 VA 400 / 385 W NA I 6.4 / 6.4 mA NA 4.5 / 2.2 A 545 / 500 VA 545 / 500 W

The following chart sitemizes the physical spacing requirements of the signal cable run with respect to order power and electrical equipment cable run. Type of electrical run Fluorescent, neon incandescent lighting fixture Unshielded power line or electrical equipment Unshielded power line or electrical equipment with signal cables enclosed in grounded conduit Power line in grounded conduit with signal cables in grounded conduit Below 2 kVA 127 mm (5") 127 mm (5") 64 mm (2 1/2") 30 mm (1 3/16")

Power of electrical run Between 2-5 kVA 127 mm (5") 305 mm (12") 152 mm (6") 76 mm (3") Above 5 kVA 127 mm (5") 610 mm (2"- 0") 305 mm (12") 152 mm (6")

Power Usage for ATM with UPS

Rated Current Consumption (Maximum Operation) 110-120 / 220-240 VAC Apparent Power Consumption (Maximum Operation) 110-120 / 220/240 VAC Real Output 110-120 VAC / 220-240 VAC Power factor Protection Class Leakage Current (Maximum) 110-120 VAC / 220-240 VAC Standby Power Consumption (no transaction)

Single Cable Installation Constrains

Relative care is required when installing signal cables in conduits. Unlike power and lightening cables, signal cables have small conductors and light isolations and will not withstand as much strain in installation. The following chart summarizessome common conduit parameters. The sum of crosssectional areas of cables being installed in conduit should not exceed 40% of the area of the conduit. Conduit size (inches) Internal diameter (inches) Area square inches 100% 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 0,622 0,824 1,049 1,38 1,61 2,067 0,3 0,53 0,86 1,5 2,04 3,36 40% 0,12 0,21 0,34 0,6 0,81 1,34 33% 0,099 0,175 0,283 0,495 0,679 1,109 25% 0,075 0,132 0,215 0,375 0,51 0,84

Heating (without device)

Rated current consumption 110-120 VAC / 220-240 VAC Apparent power consumption 110-120 VAC / 220-240 VAC Active power 110-120 VAC / 220-240 VAC

Finish

Fascia painted standard WN Grey (option any NCS or RAL color or stainless steel) Housing (Top Cover) painted standard WN Grey (option any NCS or RAL color) Safe painted standard Grey (option any NCS or RAL color)

Operating Environment (DIN EN 60721(IEC 721))

Temperature, Safe location Class 3K3 (Inside) + 5 to + 35 °C (41 to 95 F) Relative Humidity (Non Condensing) (Inside) 10 to 75 % Temperature, Fascia location (Outside with heating) -40 to + 50 °C ( -40 to 122 F) Relative Humidity (Non Condensing) (Outside) 10 to 75 % Temperature, Limited range of Operation (inside, only a short time of Operation Class 3K3) +5 to +40 °C (41 to 104 F) Relative Humidity, Limited range of Operation (inside, only a short time of Operation Class 3K3) 5 to 85 % Transport Class 2K2, Temperature -25 to + 60 C (-13 to 140 F) Transport Class 2K2, Relative Humidity 15 to 98 % Storage Class 1K2, Temperature + 5 to + 40 °C (41 to 104 F) Storage Class 1K2, Relative Humidity 5 to 85 %

Mechanical Environment (DIN EN 60721(DIN IEC 721))

Operation Standalone Unit Class 3M2 Operation Desktop Unit Class 3M3 Transport (In Original packing, on Vehicle, trailer, boat, train, and Air) Class 2M2 Storage (In Original Packing) Class 1M3 NA

Environmental Protection (Recycling)

Noise emission in accordance with DIN EN 27779 / Noise rating according to ISO 9296

Sound power level LWAd Standby / Operation Work place specific Sound pressure level LpAm Standby / Operation 6.1 B / 6.9 B 44 dB / 51 dB

ProCash 2150xe Version 0.8

Environmental Protection (SN3230 / 1/ )

For conduit runs 15.25 meters to 30.5 meters ( 50 to 100 feet), not more than 33 % of conduit area should be used. Each 90 degree conduit bend may be estimated as equal to the friction of a 9.15 meters (30 foot) length straight level conduit. If more than two 90 degree bends are used in conduit run, insert a pull box. Electro static discharge Static electricity charges are built up as a result of contact with certain floor covering and furniture. A discharge of this build up can discomfort to people and possible interference with electronic devices. The following precautions should be taken whenever possible to reduce the chance of static discharge problems. Avoid relative humidity values less than 40 %. Treat floor covering around electronic equipment with static reducing agents commercially available.

External cabling Please refer to the appropriate ATM Installation Guide for details for terminal cable access. Junction boxes, conduit, etc, are the responsibility of the customer. Local codes will dictate location and material to be used in electrical connections. Negativ pressure constraints To prevent cold weather operating problems due to induction of outside air and accompanying incursion of dirt, ATM should be housed in a positive pressure environment, however negative (vacuum) not exceeding (.05") H2O is acceptable. Tall buildings are especially prone to having negative pressure values greater than (.05") special engineering will be required if this specified pressure is exceeded

ProCash 2150xe

tunnel width 35 mm - 1.38" Short installation manual

View of Device without illuminated signage

230 (9.06")

Additional operation and maintenance space when a

Minimum Service Area

1190 (46.85") 395 (15.55") (700 - 27.56" **) 95 (3.74")

Wall hole

m (m a x a x . 36 .1 0 4.1 7

Vertical view of wall installation

")

Additional operation and maintenance space if a CCDM is used or additional installation space

880 (34.65") 700 (27.56")

max. 360 (max. 14.17")

1580 (62.2")

1750 (68.9")

830 (32.68")

950 (37.4")

1391 (54.76")

750 (29.53")

** Width of safe

2

1750 (68.9")

506 (19.92")

885 (34.84")

790* (31.1")

848 (33.39")

* Width of device head

0 6 5 5 9 ") 5. (2

628 (24.72")

683 (26.89")

658 (25.91")

2

1

2

700 (27.56")

72/43* (2.83"/1.69"*)

Additional operation and maintenance space, right or left

848 (33.39") 1213 (47.76") 1248 (49.13")

* Standard lock: 43 mm (1.69") Customer-specific lock: 72 mm (2.83")

15 (0.59")

1 Wall

Operation and maintenance space

x2

1

3 (1 5 .38 "

x1

50 (1.97")

50 (1.97")

)

5 4 3

15 (0.59")

28 6( 73 75 ") .95 (2

1 Outside wall

Drawings is not drawn to scale. All Demissions in Milimeter and (Inches). Weight in Kilo and (Pound). All Dimensions, Weight and Design, is subject to change without notice. Fore optional installation the inside floor level and the outside floor level has to be the same, if not adjustment has to be done according to the height difference.

7 5 ") .95 (2 ") .98

2 Inside wall (device side)

600 (23.62")

790 (31.1")

736 (28.98")

Ventilation space

850 (33.46")

770 (30.31")

1 Device 2 Wall 3 Floor inside 4 Floor outside 5 Possible variants see down here

350 (13.78")

800 (31.5")

350 (13.78")

Mounting structure with UL safe

3 2

1

25 (0.98")

Installation rack

Installation Frame 25mm (0.98")

Installation Frame 222mm (8.74")

1

2

3

9

5

6

I:

II:

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 469 (18.46") 179 8 (7.05") 5 1 4 2 637 (25.08") 687 (27.05") 737 (29.02") A 3 B

III:

229 (9.02") 149 (5.87") 97 (3.82") 72 (2.83")

7

X1

4 8

5

6

7

min. 125 (min. 4.92") 180* (7.09"*)

688 (27.09") 550 (21.65") 500 (19.69") 466 (18.35") 188 (7.4") 138 8 (5.43") 208 (8.19") 158 (6.22")

94 (3.7")

(min. 4.92")

192 (7.56")

min. 125

97 (3.82")

72 (2.83")

122 (4.8")

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 481 (18.94") 471 (18.54") 237 (9.33") 179 (7.05")

X3

X2

min. 40 (min. 1,57")

8

1 4 2 3

5

x5

x2

4

I:

II:

588 (23.15") 638 (25.12")

842 (33.15") 724 (28.5") 687 (27.05") 644 (25.35")

A

B

min. 40 (min. 1.57")

842 (33.15")

2 3 A B

6

6

6

7

6

6

6

7

836 (32.91")

3 1

2

3 C C 3 1 2 5

368 (14.49")

D 1 2 5

max.360 (14.17")

6

C D 3 2

D

222 (8.74")

880 (34.65") 950* (37.4"*)

11

368 (14.49")

1

10

4

5

6

9

max.360 (14.17")

46 (1.81") 10

installation frame 8 Installation rack

7 Top surface of finished floor 9 Installation frame 25mm (0.98")

10 Installation frame 222mm (8.74")

359 (14.13")

329 (12.95")

650 (25.59") 359 (14.13") 329 (12.95")

* This distance depends on the screed height. The threaded rod included

ProCash 2150xe Version 0.8

Puplished by Wincor Nixdorf International GmbH Banking Division Marketing Heinz-Nixdorf-Ring 1 D-33106 Paderborn Germany Phone +49(0)5251/693 33 01 Fax +49(0)5251/693 59 18 [email protected] http://www.wincor-nixdorf.com c Wincor Nixdorf International GmbH All Rights, including rights created by patent grant or registration of a utility model or design, are reserved. Delivery subject to availability, subject to change for technical reasons.

1 Safe 2 Mounting set for safe 3 Tear-off sensor 5 Concrete 6 Mounting set for 4 Screed

9

7

50 (1.97") 10

11

min. 125 (min. 4.92") 180* (7.09"*)

11

max.360 (14.17")

11

650 (25.59") 359 (14.13") 329 (12.95")

min. 40 (min. 1.57")

9 11

10

III :

11

371 (14.61")

650 (25.59")

700 (27.56")

1333 (52.48")

1398 (55.04")

ProCash 2150xe

tunnel width 35 mm - 1.38" Short installation manual

View of Device with illuminated signage

40 (1.57") 586 (23.07") 230 (9.06")

Additional operation and maintenance space when a Additional operation and maintenance space if a CCDM is used or additional installation space

Minimum Service Area

1190 (46.85") 395 (15.55") (700 - 27.56" **) 95 (3.74")

Wall hole

m (m a x a x . 36 .1 0 4.1 7

Vertical view of wall installation

")

880 (34.65") 700 (27.56")

max. 360 (max. 14.17")

1580 (62.2")

830 (32.68")

950 (37.4")

750 (29.53")

** Width of safe

2

1750 (68.9")

1750 (68.9")

506 (19.92")

1391 (54.76")

1333 (52.48")

683 (26.89")

628 (24.72")

790* (31.1")

848 (33.39")

* Width of device head

0 6 5 5 9 ") 5. (2

885 (34.84")

658 (25.91")

2

1

2

700 (27.56")

* Standard lock: 43 mm (1.69") Customer-specific lock: 72 mm (2.83")

72/43* (2.83"/1.69"*)

Additional operation and maintenance space, right or left

Operation and maintenance space

848 (33.39") 1213 (47.76") 1248 (49.13")

15 (0.59")

1 Wall

x2

40 (1.57")

1

3 (1 5 .38 "

x1

50 (1.97")

50 (1.97")

)

5 4 3

15 (0.59")

All Dimensions, Weight and Design, is subject to change without notice. Fore optional installation the inside floor level and the outside floor level has to be the same, if not adjustment has to be done according to the height difference.

(2

7 5 ") .95

73

2 6(

8 8.9

")

1 Outside wall

Drawings is not drawn to scale. All Demissions in Milimeter and (Inches). Weight in Kilo and (Pound).

75 ") .95 (2

2 Inside wall (device side)

600 (23.62")

736 (28.98")

Ventilation space

850 (33.46")

790 (31.1")

987 (38.86")

1 Device 2 Wall 3 Floor inside 4 Floor outside 5 Possible variants see down here

350 (13.78")

800 (31.5")

350 (13.78")

Mounting structure with UL safe

3 2

1

25 (0.98")

Installation rack

Installation Frame 25mm (0.98")

Installation Frame 222mm (8.74")

1

2

3

9

5

6

I:

II:

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 469 (18.46") 179 8 (7.05") 5 1 4 2 637 (25.08") 687 (27.05") 737 (29.02") A 3 B

III:

229 (9.02") 149 (5.87") 97 (3.82") 72 (2.83")

7

X1

4 8

5

6

7

min. 125 (min. 4.92") 180* (7.09"*)

688 (27.09") 550 (21.65") 500 (19.69") 466 (18.35") 188 (7.4") 138 8 (5.43") 208 (8.19") 158 (6.22")

94 (3.7")

(min. 4.92")

192 (7.56")

min. 125

97 (3.82")

72 (2.83")

122 (4.8")

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 481 (18.94") 471 (18.54") 237 (9.33") 179 (7.05")

X3

X2

min. 40 (min. 1,57")

8

1 4 2 3

5

x5

x2

4

I:

II:

588 (23.15") 638 (25.12")

842 (33.15") 724 (28.5") 687 (27.05") 644 (25.35")

A

B

min. 40 (min. 1.57")

842 (33.15")

2 3 A B

6

6

6

7

6

6

6

7

836 (32.91")

3 1

2

3 C C 3 1 2 5

368 (14.49")

D 1 2 5

max.360 (14.17")

6

C D 3 2

D

222 (8.74")

880 (34.65") 950* (37.4"*)

11

368 (14.49")

1

10

4

5

6

9

max.360 (14.17")

46 (1.81") 10

installation frame 8 Installation rack

7 Top surface of finished floor 9 Installation frame 25mm (0.98")

10 Installation frame 222mm (8.74")

359 (14.13")

329 (12.95")

650 (25.59") 359 (14.13") 329 (12.95")

* This distance depends on the screed height. The threaded rod included

ProCash 2150xe Version 0.8

Puplished by Wincor Nixdorf International GmbH Banking Division Marketing Heinz-Nixdorf-Ring 1 D-33106 Paderborn Germany Phone +49(0)5251/693 33 01 Fax +49(0)5251/693 59 18 [email protected] http://www.wincor-nixdorf.com c Wincor Nixdorf International GmbH All Rights, including rights created by patent grant or registration of a utility model or design, are reserved. Delivery subject to availability, subject to change for technical reasons.

1 Safe 2 Mounting set for safe 3 Tear-off sensor 5 Concrete 6 Mounting set for 4 Screed

9

7

50 (1.97") 10

11

min. 125 (min. 4.92") 180* (7.09"*)

11

max.360 (14.17")

11

650 (25.59") 359 (14.13") 329 (12.95")

min. 40 (min. 1.57")

9 11

10

III :

11

371 (14.61")

650 (25.59")

700 (27.56")

1615 (63.58")

ProCash 2150xe

tunnel width 60 mm - 2.36" Short installation manual

View of Device without illuminated signage

230 (9.06")

Additional operation and maintenance space when a Additional operation and maintenance space if a CCDM is used or additional installation space

Minimum Service Area

1190 (46.85") 395 (15.55") (700 - 27.56" **) 95 (3.74")

Wall hole

m (m a x a x . 33 .1 5 3.1 9

Vertical view of wall installation

")

880 (34.65") 700 (27.56")

max. 335 (max. 13.19")

1580 (62.2")

950 (37.4")

1750 (68.9")

750 (29.53")

** Width of safe

830 (32.68")

2

1750 (68.9")

506 (19.92")

1333 (52.48")

790* (31.1")

848 (33.39")

* Width of device head

885 (34.84")

0 6 5 5 9 ") 5. (2

628 (24.72")

683 (26.89")

658 (25.91")

2

1

2

700 (27.56")

72/43* (2.83"/1.69"*)

* Standard lock: 43 mm (1.69") Customer-specific lock: 72 mm (2.83")

Additional operation and maintenance space, right or left

848 (33.39") 1188 (46.77") 1248 (49.13")

15 (0.59")

1 Wall

Operation and maintenance space

73

.8 (2

6 (2 0 .36 "

x2

1

7"

)

x1

50 (1.97")

50 (1.97")

5 4 3

15 (0.59")

)

73

1 Outside wall

Drawings is not drawn to scale. All Demissions in Milimeter and (Inches). Weight in Kilo and (Pound). All Dimensions, Weight and Design, is subject to change without notice. Fore optional installation the inside floor level and the outside floor level has to be the same, if not adjustment has to be done according to the height difference.

.8 2 28 2(

")

2 Inside wall (device side)

600 (23.62")

732 (28.82")

790 (31.1")

Ventilation space

875 (34.45")

781 (30.75")

1 Device 2 Wall 3 Floor inside 4 Floor outside 5 Possible variants see down here

350 (13.78")

800 (31.5")

350 (13.78")

Mounting structure with UL safe

3 2

1

25 (0.98")

Installation rack

Installation Frame 25mm (0.98")

Installation Frame 222mm (8.74")

1

2

3

9

5

6

I:

II:

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 469 (18.46") 179 8 (7.05") 5 1 4 2 637 (25.08") 687 (27.05") 737 (29.02") A 3 B

III:

229 (9.02") 149 (5.87") 97 (3.82") 72 (2.83")

7

X1

4 8

5

6

7

min. 125 (min. 4.92") 180* (7.09"*)

688 (27.09") 550 (21.65") 500 (19.69") 466 (18.35") 188 (7.4") 138 8 (5.43") 208 (8.19") 158 (6.22")

94 (3.7")

(min. 4.92")

192 (7.56")

min. 125

97 (3.82")

72 (2.83")

122 (4.8")

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 481 (18.94") 471 (18.54") 237 (9.33") 179 (7.05")

X3

X2

min. 40 (min. 1,57")

8

1 4 2 3

5

x5

x2

4

I:

II:

588 (23.15") 638 (25.12")

842 (33.15") 724 (28.5") 687 (27.05") 644 (25.35")

A

B

min. 40 (min. 1.57")

842 (33.15")

2 3 A B

6

6

6

7

6

6

6

7

836 (32.91")

3 1

2

3 C C 3 1 2 5

343 (13.5")

D 1 2 5 343 (13.5") 46 (1.81") 10

max.335 (13.19")

6

C D 3 2

D

222 (8.74")

10

4

5

6

9

max.335 (13.19")

installation frame 8 Installation rack

7 Top surface of finished floor 9 Installation frame 25mm (0.98")

10 Installation frame 222mm (8.74")

359 (14.13")

329 (12.95")

650 (25.59") 359 (14.13") 329 (12.95")

* This distance depends on the screed height. The threaded rod included

ProCash 2150xe Version 0.8

Puplished by Wincor Nixdorf International GmbH Banking Division Marketing Heinz-Nixdorf-Ring 1 D-33106 Paderborn Germany Phone +49(0)5251/693 33 01 Fax +49(0)5251/693 59 18 [email protected] http://www.wincor-nixdorf.com c Wincor Nixdorf International GmbH All Rights, including rights created by patent grant or registration of a utility model or design, are reserved. Delivery subject to availability, subject to change for technical reasons.

1 Safe 2 Mounting set for safe 3 Tear-off sensor 5 Concrete 6 Mounting set for 4 Screed

9

7

50 (1.97") 10

11

11

min. 125 (min. 4.92") 180* (7.09"*)

11

max.335 (13.19")

11

650 (25.59") 359 (14.13") 329 (12.95")

min. 40 (min. 1.57")

9 11

10

III :

11

346 (13.62")

650 (25.59")

880 (34.65") 950* (37.4"*)

1

700 (27.56")

1391 (54.76")

1409 (55.47")

ProCash 2150xe

tunnel width 60 mm - 2.36" Short installation manual

View of Device with illuminated signage

40 (1.57") 586 (23.07") 230 (9.06") 75 (2.95")

Additional operation and maintenance space when a

Minimum Service Area

1190 (46.85") 395 (15.55") (700 - 27.56" **) 95 (3.74")

Wall hole

m (m a x a x . 33 .1 5 3.1 9

Vertical view of wall installation

")

Additional operation and maintenance space if a CCDM is used or additional installation space

880 (34.65") 700 (27.56")

max. 335 (max. 13.19")

1580 (62.2")

950 (37.4")

750 (29.53")

** Width of safe

830 (32.68")

2

1750 (68.9")

506 (19.92")

1391 (54.76")

1333 (52.48")

683 (26.89")

628 (24.72")

790* (31.1")

848 (33.39")

* Width of device head

0 6 5 5 9 ") 5. (2

885 (34.84")

658 (25.91")

2

1

2

Additional operation and maintenance space, right or left

(2.83"/1.69")*

* Standard lock: 43 mm (1.69") Customer-specific lock: 72 mm (2.83")

700 (27.56")

72/43*

40 (1.57")

Operation and maintenance space

73

")

x2

848 (33.39") 1188 (46.77") 1248 (49.13")

15 (0.59")

1 Wall

1

.8 (2

) 7"

75

(2

.95

x1

50 (1.97")

50 (1.97")

5 4 3

All Dimensions, Weight and Design, is subject to change without notice. Fore optional installation the inside floor level and the outside floor level has to be the same, if not adjustment has to be done according to the height difference.

73

2 2(

2 8.8

")

1 Outside wall

Drawings is not drawn to scale. All Demissions in Milimeter and (Inches). Weight in Kilo and (Pound).

6 (2 0 .36

")

2 Inside wall (device side)

15 (0.59")

Ventilation space

600 (23.62")

732 (28.82")

790 (31.1")

875 (34.45")

962 (37.87")

1 Device 2 Wall 3 Floor inside 4 Floor outside 5 Possible variants see down here

350 (13.78")

800 (31.5")

350 (13.78")

Mounting structure with UL safe

3 2

1

25 (0.98")

Installation rack

Installation Frame 25mm (0.98")

Installation Frame 222mm (8.74")

1

2

3

9

5

6

I:

II:

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 469 (18.46") 179 8 (7.05") 5 1 4 2 637 (25.08") 687 (27.05") 737 (29.02") A 3 B

III:

229 (9.02") 149 (5.87") 97 (3.82") 72 (2.83")

7

X1

4 8

5

6

7

min. 125 (min. 4.92") 180* (7.09"*)

688 (27.09") 550 (21.65") 500 (19.69") 466 (18.35") 188 (7.4") 138 8 (5.43") 208 (8.19") 158 (6.22")

94 (3.7")

(min. 4.92")

192 (7.56")

min. 125

97 (3.82")

72 (2.83")

122 (4.8")

694 (27.32") 630 (24.8") 584 (22.99") 539 (21.22") 481 (18.94") 471 (18.54") 237 (9.33") 179 (7.05")

X3

X2

min. 40 (min. 1,57")

8

1 4 2 3

5

x5

x2

4

I:

II:

588 (23.15") 638 (25.12")

842 (33.15") 724 (28.5") 687 (27.05") 644 (25.35")

A

B

min. 40 (min. 1.57")

842 (33.15")

2 3 A B

6

6

6

7

6

6

6

7

836 (32.91")

3 1

2

3 C C 3 1 2 5

343 (13.5")

D 1 2 5 343 (13.5") 46 (1.81") 10

max.335 (13.19")

6

C D 3 2

D

222 (8.74")

10

4

5

6

9

max.335 (13.19")

installation frame 8 Installation rack

7 Top surface of finished floor 9 Installation frame 25mm (0.98")

10 Installation frame 222mm (8.74")

359 (14.13")

329 (12.95")

650 (25.59") 359 (14.13") 329 (12.95")

* This distance depends on the screed height. The threaded rod included

ProCash 2150xe Version 0.8

Puplished by Wincor Nixdorf International GmbH Banking Division Marketing Heinz-Nixdorf-Ring 1 D-33106 Paderborn Germany Phone +49(0)5251/693 33 01 Fax +49(0)5251/693 59 18 [email protected] http://www.wincor-nixdorf.com c Wincor Nixdorf International GmbH All Rights, including rights created by patent grant or registration of a utility model or design, are reserved. Delivery subject to availability, subject to change for technical reasons.

1 Safe 2 Mounting set for safe 3 Tear-off sensor 5 Concrete 6 Mounting set for 4 Screed

9

7

50 (1.97") 10

11

11

min. 125 (min. 4.92") 180* (7.09"*)

11

max.335 (13.19")

11

650 (25.59") 359 (14.13") 329 (12.95")

min. 40 (min. 1.57")

9 11

10

III :

11

346 (13.62")

650 (25.59")

880 (34.65") 950* (37.4"*)

1

700 (27.56")

1750 (68.9")

1630 (64.17")

Information

Grafik1

5 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

302753


You might also be interested in

BETA
AC Induction Motors Installation, Operation and Maintenance Manual
14FZ.fm.save
4727REVNApds.fm
britStand.set