Read ImmunoassaySurvey2010.pdf text version

www.clpmag.com

Immunoassay Analyzers Survey '10

1) What is the name of your company's immunoassay analyzer product or product line?

Alere

Jared Sousa [email protected] (877) 441-7440 www.alere.com

Alere

Michelle Fradette [email protected] alere.com (781) 647-3900 www.alere.com

Alere

Michelle Fradette [email protected] alere.com (781) 647-3900 www.alere.com

Ortho Clinical Diagnostics Inc

Mark Steelman [email protected] (800) 828-6316 www.orthoclinical.com

AIMS® System with AtheNA Multi-Lyte® Test System

DS2TM ELISA Processing SystemDS2®

DSX® Automated System

VITROS® 3600 Immunodiagnostic System

2) What does this product detect?

A multiplexed, fluorescent, beadbased system to simultaneously perform multiple immunoassays, for Infectious and autoimmune disease from a single sample, in one well

An open system, the DS2 is ideal for virtually any ELISA application, including autoimmune, infectious, and enteric assays from Alere.

The DSX is a fully automated four-plate processing system capable of performing multiple assays per plate including autoimmune, infectious disease, and enteric assays from Alere. a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

High-capacity immunoassay system that provides labs with a solution to address their quality, labor, and cost challenges.

3) This product is used in:

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

4) Intended volume use:

5) What is the throughput, under ideal conditions?

Two full, 96-microwell plates can be processed with full walk-away automation in approximately 5 hours. A maximum of four AtheNA Multi-Lyte assays can be performed per the two microwell plates.

Assay dependent. With Alere, two full plates in less than 4 hours.

Assay dependent. With Alere, four full plates in less than 8 hours.

Up to 189 tests per hour

6) Are there any automation options?

AIMS is an integrated System providing full walk-away automation for sample handling.

Full automation including sample dilution and distribution, reading with auto-data reduction QC and more.

Full automation including sample dilution and distribution, incubation, washing, and reagent dispensing.

Yes

7) Does this product include an integrated chemistry analyzer?

Yes

No

No

No

8) What is the price range?

List price is $149,900. Financing options such as reagent rental and lease are available.

List price is $48,200

List price is $77,930

Contact company

9) What differentiates this product from others on the market?

AtheNA utilizes Intra-Well Calibration Technology® for result confidence by generating a patient-specific, multipoint calibration curve. SAVe Diluent® reduces pipetting errors, through color change.

Broad menu of ELISA reagents designed in same format for ease of use that supports increased automation with SAVe diluent, a unique sample identifier that ensures sample pipetting accuracy (and more).

ELISA reagents are designed in the same format, providing increased ease of use to support further automation. Reagents can be combined to same plate increasing throughput, with flexible incubation.

Uses proprietary Intellicheck® technology to perform, monitor, document, and verify diagnostic checks throughout sample and assay processing to reduce the potential for misreported results.

14

November 2010 | clpmag.com

www.clpmag.com

Immunoassay Analyzers Survey '10

1) What is the name of your company's immunoassay analyzer product or product line?

Ortho Clinical Diagnostics

Mark Steelman [email protected] (800) 828-6316 www.orthoclinical.com

Siemens Healthcare Diagnostics

Louise Loughran [email protected] siemens.com (847) 267-5300 www.usa.siemens.com/ diagnostics

Siemens Healthcare Diagnostics

Louise Loughran [email protected] siemens.com (847) 267-5300 www.usa.siemens.com/ diagnostics

ADVIA Centaur XP

Siemens Healthcare Diagnostics

Martu Richards [email protected] siemens.com (914) 524-3828 www.siemens.com/ diagnostics

VITROS® ECiQ Immunodiagnostic System

ADVIA Centaur CP

IMMULITE 2000 XPi Immunoassay System* (*pending FDA approval, not available for sale in the US) 80+ assays covering 15 disease states such as repro endo, bone metabolism, anemia, and infectious disease, including 230+ specific allergens. Analysis methodology is enzyme-enhanced chemiluminescence a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

2) What does this product detect?

Routine and specialty immunodiagnostic testing.

The ADVIA Centaur CP is a fully automated immunoassay platform with a comprehensive, disease-focused menu.

The ADVIA Centaur XP is a fully automated immunoassay platform with a comprehensive, diseasefocused menu.

3) This product is used in:

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

4) Intended volume use:

5) What is the throughput, under ideal conditions?

Up to 90 reportable patient results per hour

Up to 180 tests per hour

Up to 240 tests per hour

Up 2O0 tests per hour for the IMMULITE 2000 XPi* (*pending FDA approval, not available for sale in the US)

6) Are there any automation options?

No

None

Connectivity with the following: VersaCell, ADVIA Automation, and StreamLAB

Yes, connects to Siemens automation solutions only via VersaCell (sample management system)

7) Does this product include an integrated chemistry analyzer?

No

No

No

No

8) What is the price range?

Contact company

Varies, depends on contract

Varies, depends on contract

Not available (system pending FDA approval, not available for sale in the US)

9) What differentiates this product from others on the market?

Uses proprietary Intellicheck® technology to perform, monitor, document, and verify diagnostic checks throughout sample and assay processing to reduce the potential of misreported results.

Broad 63 assay menu: routine, cardiac including BNP/TnI-Ultra, full hepatitis, oncology, and reproductive tests; 15 reagents onboard; throughput up to 180 tests per hour; Benchtop platform, STAT capability.

Broad 67-assay menu: routine, cardiac including BNP/TnI Ultra, full hepatitis/HIV, oncology, and reproductive tests; 30 onboard reagents; high throughput, up to 240 tests per hour; STAT capability.

IMMULITE 2000 XPi has comprehensive IA menu; 90-day reagent onboard stability; reagent and consumables onboard capacity up to 5 hours walkaway time; automation ready; solid instrument reliability.

16

November 2010 | clpmag.com

Siemens Healthcare Diagnostics

Martu Richards [email protected] siemens.com (914) 524-3828 www.siemens.com/ diagnostics

IMMULITE 1000 Immunoassay System

Thermo Fisher Scientific

Tosoh Bioscience Inc

Kathy Ruzich [email protected] thermofisher.com (800) 232-3342 www.thermo.com/ diagnostics

Thermo Scientific MGC 240TM benchtop analyzer

Michael McHugh [email protected] (800) 248-6764 www.diagnostics.us. tosohbioscience.com

Tosoh Bioscience Inc

Michael Mchugh [email protected] (800) 248-6764 www.diagnostics.us. tosohbioscience.com

Tosoh Bioscience Inc

Michael Mchugh [email protected] (800) 248-6764 www.diagnostics.us. tosohbioscience.com

AIA-2000 Automated Immunoassay Analyzer

AIA-600 II Automated Immunoassay Analyzer

AIA-600 II Automated Immunoassay Analyzer

80+ assays covering 15 disease states such as repro endo, bone metabolism, anemia, and infectious disease, including 230+ specific allergens. Analysis methodology is enzyme-enhanced chemiluminescence. a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

Drugs-of-abuse testing and therapeutic drug management. Used for drugs-of-abuse screens, therapeutic drug monitoring, immunosuppressive diagnostics assays, and specimen validity tests.

TSH, FT4, FT3, T4, T3, TU, bHCG, E2, FSH, LH, Prog, PRL, Tes, AFP, CEA, PSA, CA125, 27.29, CA 19.9, BMG, C-Pep, Cort, HGH, IgE, IRI, PAP, CKMB, Myo, cTnI2, Fer, iPTH (CystatinC & HbA1c available 01/2011). a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

TSH, FT4, FT3, T4, T3, TU, bHCG, E2, FSH, LH, Prog, PRL, Tes, AFP, CEA, PSA, CA125, 27.29, CA 19.9, BMG, C-Pep, Cort, HGH, IgE, IRI, PAP, CKMB, Myo, cTnI2, Fer, iPTH (CystatinC & HbA1c available 01/2011). a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

TSH, FT4, FT3, T4, T3, TU, bHCG, E2, FSH, LH, Prog, PRL, Tes, AFP, CEA, PSA, CA125, 27.29, CA 19.9, BMG, C-Pep, Cort, HGH, IgE, IRI, PAP, CKMB, Myo, cTnI2, Fer, iPTH (CystatinC & HbA1c available 01/2011). a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

a hospital or other large laboratory a physician's office at the point of care other high volume intermediate or variable low volume

Up 120 tests per hour for the IMMULITE 1000

Capable of running 240 tests per hour and handling up to 24, tworeagent immunoassays per run. It provides a 24-hour cooling system so reagents can be left in place on the instrument.

200 tests per hour, first result in 18 minutes for most assays

60 tests per hour, first STAT result in 18 minutes for most assays (<1500 tests/month)

60 tests per hour, first STAT result in 18 minutes for most assays (<1500 tests/month)

Yes, a stand-alone system with no connectivity to Siemens line automation solutions.

Adapts to various primary tubes and sample cups and has an automatic cuvette QC. It features auto rerun, auto dilution, and sample predilution, including auto alarms for washing and waste containers.

Automated daily maintenance, record keeping, inventory management and pretreatment.

Random access; daily maintenance, sample level sensing, dilution/pretreatment, bar code reader.

Random access; daily maintenance, sample level sensing, dilution/pretreatment, bar code reader.

No

No

No

No

No

List Price IMMULITE 1000 System = $75,000 each

Contact company

List price of $175,000, various acquisition options available

List price of $70,000, various acquisition options available

List price of $70,000, various acquisition options available

IMMULITE 1000 has comprehensive test menu of routine, specialty, and esoteric assays; compact footprint and solid reliability.

This small and compact benchtop analyzer performs like the larger instruments in supporting all testing requirements. It features a unique design and easy maintenance with bar coding capabilities.

Same throughput of 200 tests per hour for any combination of ST assays; uses unit dose test cup, dry reagents, hence no waste and better stability; 90-day calibration curve stability on most assays.

Compact benchtop analyzer with proven reliability; dual clot detection, unit dose test cup dry reagent format provides better stability, no waste; 90-day calibration stability for most assays.

Compact benchtop analyzer with proven reliability; dual clot detection, unit dose test cup dry reagent format provides better stability, no waste; 90-day calibration stability for most assays.