Read SpecificationsforSupplyTestingandCommissioningof10.pdf text version

r-

DG:DD/TxD/10kW /2011/EV /

PRASAR BHARA TI . (Broadcasting Corporation of India)

(~ .. ..~.:c:''i....-t :~ .·......· Qlr~~.:c:'II<::-1<-t

Directora,te General Doordarshan

~-c..G~'i-1 ~, cnl'-l-c..I~Of""~

+=rf7"T,

Doordarshan Bhawan, Copernicus ~ rG.~1 - ~~ooo~ New Delhi - 110001

Marg

Specification No: DG:DD/TxD/HPT/EV-2011 Dated 31.05.2011

SPECIFICATIONS OF SUPPLY TESTING AND COMMISSIONING OF lOKW SOLID STATE VHFIUHF ANALOG TV TRANSMITTER SYSTEM TQ, BE INSTALLED AT 15 LOCATIONS

Page 1 of 88

DG:DD/TxD/l0kW /2011/EV /

SPECIFICATIONS OF SUPPLY TESTING AND COMMISSIONING OF 10KW SOLID STATE VHF/UHF ANALOG TV TRANSMITTER SYSTEM TO BE INSTALLED AT 15 LOCATIONS.

Table of Contents

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Introd uction The scope of the tender Essentia I el igi bi Iity crite ria fo r bidder. General Requirements for completing Del ivery Guara ntee Ma intenance support/spa res LocaI Representative/Dea ler ; ;; the offer ; ;;;;;.;.;.;;;.; ;; ;;; ; ; ; ;.;;; 5 6 6 7 10 10 11 12 12 13 13 ",'

",j"

,i

Tra ining at 0 EM' s Wo rks (Optio na I) Training at DD Sites Inspection Test·mg an dC 0 m m ISSIO n I ng a t'tSI e BOM (Unpriced) Local/remote Softwa re Input, Monitoring and Measuring Equipment Rack Monitoring and control Facility ~ ~

\;~,1"'1(;;,

11 .

12 . 13. 14.

;

.',

. 14 14 15 16 16 16 17

15.

16. 17.

Tra nsm itter System Exciter System Power Amplifier System Liquid Cooli ng system Upgradeability to DVB-T2 Transmitter System , .' ,................·. : ,

1 8. 19.

20. 21. 22. 23.

18 19 20 21 24 26 26 32

Technical Specifications for one 10 kW Analog TV Transmitter Com pliance Statement

ANN EXURE-IA BILL OF MATERIAL FOR 10KW VHF Band III TV TRANSMITIER SYSTEM & STATION ITEMS FOR ONE LOCATION AN NEXURE-IB

Page 2 of 88

DG:DD/TxD/10kW /2011/EV /

BILL OF MATERIAL FOR 10KW UHF Band IV/V TV TRANSMITIER SYSTEM & STATION ITEMS FOR ONE LOCATION

.

32 38 38 39

Ann ex ure 11-1 Specifications of 10 kW dummy load Ann exure 112 Specifications of 10kw Broadcast Power Monitor

39 41

Annexure 11-3 Specifications of Seven Port Patch Panel.; ' ,

41 42 42 43 43 Amplifier ~ , 43 44 ,.·....................................................................................... 46 46 46 47 Amplifier 8W 47 48 ~ 49 51 52 52 53 ' 53 57

An nexure 11-4 Specifications of Indoor Coaxial Feeder Cu Components Annexure 11-5

A. B.

C. D.

Specifications of Sta ndard 19" Rack Specifications of Video Equalizing Distribution Specifications of Video Audio Switcher Specifications of Audio Jackpanel-( N/C) 2x24 Specification of Video Jack Panels Audio Patch Cords (2ft) Video Patch Cords (2 ft) Specifications of Audio Stereo Monitoring Specifications of Audio Distribution Specifications for Audio Processor Specification of Am plispeaker

E. F. G.

H.

I.

J. K.

Am plifier

Annexure 11-6 Specifications of Colour Test Pattern & Tone Generator Annexure 11-7 Specifications of T.V. Demodulator Annexure 11-8 Specifications of Waveform Annexure 11-9 Specifications of VU Meter Annexure 11-10 , , '".", .., Mon itor

57 59 59 60 Page 3 of 88

_.

DG:DD/TxD/l0kW

/2011/EV /

Specifications of RF Ana Iyser Annexure 11-11 Specifications for Aud io Ana Iyser An nexu re 11-12 An nexure 11-13 Specifications of Computer With 600 VA UPS and Laserjet Printer Ann exure 11-14 Specifications of Professiona II RD for C-Band/Ku-Ba nd An nexu re 11-15 Specifications of 60 KVA Annexure 11-16 Specifications of 75 KVA AVR Fig. 1 Signa I Flow Diagram Fig. 2 System Diagra m Fig. 3 Details of 7 - Port Patch Panel

t ········································································································································

60 64 64 66 67 67 69 69 74 74 83 83 86 87 88

Page 4 of 88

DG:DD/TxD/10kW /2011/EV /

SPECIFICATIONS OF SUPPLY TESTING AND COMMISSIONING OF 10KW SOLID STATE VHF/UHF ANALOG TV TRANSMITTER SYSTEM TO BE INSTALLED AT 15 LOCATIONS.

1.

Introduction

(a) Doordarshan (DD) intends to install lOkW, VHF/UHF Analog TV Transmitters Digital upgradable to DVB- T2, at 15 Locations as given in Table 1. (b) These transmitters shall be based on latest technology and shall have provision for remote monitoring, remote operation/remote Control. (c) The TV transmitters are to be supplied as a complete system including input, monitoring and measuring equipment, cooling system, UPS,· isolation transformer, AVR, interconnecting cables etc. (d) "Transmitter System" includes Transmitter alongwith its associated equipment such as cooling system, dummy load, RF rigid lines, 7 Port Patch Panel, Input, monitoring and measuring Equipment. (e) A list of items/equipment which is treated essential for completeness of the system is provided with these specifications in Annexure-IA and lB. Any other item/equipment, which is essential for thecompl~t~ness of the systernshquld also be included in the offer. It should be ensured by the bidder that the system is complete in all respects. (t) Operating Channels for the 15 locations are given in Table 1 below:

Table 1

S. No. Station Operating Channel /Freq (PAL BIG)

12 (22}-230 MHz) 10 (209-216 MHz) 34 (406-414 MHz) 7 (188-195 MHz) 8 (195-202 MHz) 6 (181-188 MHz) 9 (202-209 MHz) 21(470-478

,

1. .. "Di~rug~rh ,,' Tura 2. Kolkata 3. Daltonganj 4. Bhawanipatna 5. 6. 7. 8. 9. 10.. Jaiselmer Agra Fazilka~

,

..

MHz)

Mau Vishakhapatnam 11. Anantpur 12. Jabalpur

21 (470-478 MHz) 7 (188-195MHz) 11 (216-223 MHz) 8 (195-202 MHz)

Page 5 of 88

\.l.

.;,

---------------------------------------~..i )

'~l I' ·

II

I\

DG:DD/TxD/10kW /2011/EV /

13. 14. 15.

Raipur Pune Bhuj

5 (174-181 MHz) 5 (174-181 MHz) 10 (209-216 MHz)

! '~l'

~

I (

2. The scope of the tender:

'1 '\

1

The scope of the present tender is to supply. the required. set .of.equipment,. acceptance testing & commissioning at sites, training etc. as specified in these specifications. The installation of the equipment at site will be done by Doordarshan departmentally. The main equipment includes the following:

"1 ·

"'t

(a) 10kW Analog Transmitter lB.

upgradeableto

DVB-T2. A BOM is given in Annexure IA and Suggestive'signal flow diagram in

(b) Input and monitoring equipment with'pre.:.wired'racks;1 Fig. 1 and BOM in Annexure IA and IB are enclosed.

(c) Power Supply System including UPS, isolation transformer, AVR etc. A suggestive System Diagram is given in Fig.2.

3.

Essential eligibility criteria for bidder

·.· 'ill-'I)I;"';

(a) (b)

The bidder should be the original equipment manufacturer (OEM) of TV Transmitter or their authorized representative/dealer. The OEM of the transmitter must have an experience of manufacturing and supplying TV transmitters at least for last 10 years. Documentary evidence to support this must be provided.

(c)

The bidder/the OEM should have entered into contract/contracts, for supplying, testing and commissioning, with reputed Broadcasters for similar quantity and power of transmitters. Copies of such contract/contracts with proof of satisfactory performance of such contract/contracts in the following format must be submitted with the offer, failing which the offer shall be rejected. Doordarshan reserves the rights to get performance feedback of the transmitters from any of the above broadcasters named by the bidder/the OEM. Order Transmitter Quantity Name of the Details* of performance No. with Type, Model broadcaster with certificates of the contract. date, and Power ' postal full reference of address to whom transmitter transmitter was supplied. (1) (2) (3) (4) (5)

Page 6 of 88

DG:DD/TxD/lOkW /2011/EV /

* Copies of actual performance

(d)

certificates are to be en,closed by the bidder.

In case the bidder is the authorized representative/dealer, it must be in the business of sales and supply of T.V. or Radio transmitter system for at least three years. Documentary evidence to support this must be provided. The bidder must have his local office/ authorized representative/dealer in India for after sales support. The local office/ authorized representative/dealer will be the nodal point for resolving issues related to testing and commissioning at site and after sales support. Any module of transmitter or other equipment requiring repairs will be handed over to local office/ authorized representative/dealer that will arrange· repairs locally or export the defective modules to OEM's factory and re-import after repairs. It is the responsibility of local office/ authorized representative/dealer to arrange the repair/replacement of faulty items. The cost of transportation, repairs etc. shall be borne by the bidder during the Guarantee period. The OEM of the TV Transmitter must have his own local office or its representatives/dealers in India for after sale support. After sales service support for the repairs/maintenance of transmitter system after the completion of guarantee period, shall also be provided by the respective OEMs of the transmitter and other allied equipment either directly or through their representatives/dealers in India. A certificate, on their letterhead, in this regard duly signed by the respective OEMs mustbe submitted with the offer.

(e)

(f)

4. General Requirements for completing the offer (a) The bidder will attach all relevant technical documents in English like "offered bill of materials with quantity, :'makeandmodel~',"\Technical pamphlets, manuals, data sheets, drawings, block diagrams, photographs etc. of all equipment offered with the transmitter system that are essential to evaluate the offer for technical suitability with reference to DO specifications. A copy of the Installation manual, Operation and maintenance manual must be enclosed with technical bid for assessing the Transmitter system. The transmitter shall be installed by DD engineers as per the instructions given in the installation manual. The installation manual and the operation & maintenance manual should include at least the details given in next two paras: . . (b) The installation manual must describe the following information: i. A suggestive floor equipment layout plan drawing with dimensions in meters for installation of the TV transmitter system in a transmitter hall with all allied equipment. H. Diagram showing the isometric view of TV Transmitter and allied equipment with dimensions in meters are to be provided. HI. All installation drawings with dimensions in respect of all supplied equipment are to be provided.

Page 7 of 88

.- ····

l ··.·· ;j

.;';j'"

" ·.·

;,:

.i...,

····. ',',;1;,.,' ,

.··.. , ··.··. '

;

,,-j: "'I.:

.

DG:DD/TxD/10kW /2011/EV /

All mechanical assembly drawings of the TV transmitter system with dimensions are to be provided. v. All the views, i.e. front, rear, top and side (open) of the TV Transmitters with dimensions are to be provided. VI. Detailed descriptions for installation of cooling system alongwith the diagrams showing the coolant flow to the transmitter and the outlet to heat exchanger system should be provided. V11. Typical installation drawings with dimensions of heat exchanger are to be provided. V111. The details of unpacking are to be provided."'" "", IX. A detailed write up in English regarding installation of TV Transmitter system along with its associated equipment items should be provided. x. The procedure of alignment and adjustment of various assemblies & subassemblies of TV Transmitter such as Exciter, PA, Control Circuit, output stage etc. should be described in detail with practical example in the installation manual. Xl. All Do's and Don 'tSl which ..are, .essentialli .ford safe ..installation of the Transmitter System should be described in the installation manual. XII. An inter-wiring diagram for all equipment installed in the input/monitoring rack must be provided in this manual.

IV.

(c) Operation and Maintenance Manual must describe in it the following information: i. General description of transmitter; transmitter block diagram/ Schematic drawings indicating the details of different blocks, modules and redundancy incorporated in transmitter and its subsystems. 11. General description and structural overview of the Transmitter racks and Pump Racks indicating the position of different modules, units, power distribution etc. front and rear, top, side (open) views of the transmitters rack with dimensions. 111. Colour Photographs of the Transmitters and various display screens showing monitorable and measurable Parameters. IV. A detailed description with all relevant circuit diagrams of the transmitter should be provided with details of test points: v. The details of all electrical circuits in various stages of the Transmitter used along with their write-ups are to be provided in this manual. VI. General description of RF signal flow diagram for complete RF chain from exciter to filter output with information about power level and frequency at input & output of each stage. V11. Description of Transmitter interlocks, protections under abnormal conditions and schematic drawing indicating interconnections to different transmitter units, external units and accessories like dummy load, changeover switches, reject

Page 8 of 88

DG:DD/TxD/10kW /2011/EV /

loads, 7 Port Patch Panel, cooling pumps etc. which are wired in Transmitter interlocks.' . Vlll. Details and Schematic drawings of liquid cooling system with description. IX. Details and schematic drawings of remote control & operation by telemetry system using Ethernet/ SNMP/web browser and broadband connection along with screen shots of the interface displays. The remotely monitorable and controllable parameters of the transmitter should be clearly indicated. x. General description of Transmitter Control System and schematic drawing for control signal distribution. Xl. A detailed description with all relevant circuit diagrams for the control circuit of the transmitter should be provided. Xu. General description of (1 + 1) exciter system, block schematic showing details of all sub units. Exciter Front and rear views indicating all inputs, outputs and interfaces. XUL General description and architecture of Power Amplifier's block schematic drawings, Front, open and rear views indicating all inputs, outputs and interfaces. XIV. Full detailed description and circuit analysis of Exciter system, PA, DC Power Supply Unit must be provided with circuit diagram. XV. Description of reserve power capacity and output power regulation mechanism of the Power Amplifiers and Transmitter with failure ofRF devices or PAs. XVI. Details of Splitter / Combiner system's schematic drawings used in the transmitter. XVII. The operating' 'manual 'should'havedescription regarding various interfaces, connectors, connecting cables and accessories required for the satisfactory function of the TV Transmitter.: :', XVlll. A complete list of all parts/transistors/ICs VLSI/ Components used in the transmitter must be provided in this manual. XIX. Technical data sheet of all high power RF devices/RF components used in the transmitter. XX. Details .of, MTBFAMean. Time -between Failures) "in respect of power semiconductor" & MTTR (Mean time to repairs) "in respect of Pallets/PCBs etc." used in the transmitter. XXI. All details of putting "ON" the transmitter, with the sequence of operation of the Transmitter. XXII. Procedure for changing the frequency of operation of the transmitters. XXUL Procedure for operating the transmitter on low power upto 6 dB below rated power. XXIV. The detailed procedure and' possibilities of By-passing PA's DC power supply unit and control circuit should be described with diagrams in this manual. XXV. The description of manual operation of control system and cooling system.

Page 9 of 88

. . . ··

': ~ ~~ ~"

"

!",'

'--,.'

-------------------------------------

.---------_.

, ji1

1

DG: DD/TxD/l0kW

/2011/EV /

XXVI. All Do's and Don'ts which are essential for safe Operation of the Transmitter should be. described in the Operation manual. ', ," \'

I '.

& Maintenance & Maintenance

,

XXVll. The various test and measuring equipment required and essential for the routine maint~nance and calibration' along . with . the procedure for taking such measurement should be provided in the manual. XXVllI. Various test fixtures and accessories required for the maintenance/ repair of the TV Transmitter should be clearly described in this manual. XXIX. The detailed procedure for trouble shooting of the TV Transmitter preferably up to component level should be'described in the manuaL'" xxx. The systematic trouble shooting/ fault tree and flow diagram should be provided for diagnosis 6fthe faults;withtheir.remedial measures in this manual. XXXI. The maintenance schedule for the transmitter should also be described in the manual. XXXll. General description of electrical power distribution and schematic drawing of power supply system used for the transmitter system.

5. Delivery

One complete set of the 'transmitter system' with all allied equipment is to be delivered in good condition at each of the 15 DD sites mentioned in Table 1. It will be the responsibility of the bidder to ensure safe delivery of all the equipment at each site.

6. Guarantee

(a) The respective manufacturers shall guarantee the satisfactory working of all the equipment of the Transmitter System, for twenty four months from the date of completion of acceptance test at site or for thirty months from the date of receipt of last accepted consignment at site whichever is earlier. Any defect/ failure of any component, module, assembly of any equipment and its non-performance during this period is to be set right by the bidder/ manufacturer(s) free of cost and deliver the repaired/replaced item(s) at the premises of the consIgnee. (b) A Guarantee certificate, as in Para 6(a),from the respective OEMs on their letter heads, for all third party bought equipment/items offered with the transmitter system, must also be attached with the offer. (c) Any Future upgrade of software or Software updates for all the equipment (such as Transmitter, all input, monitoring, measuring and allied equipment etc.) within twenty four months of commissioning of the Transmitter System or for thirty months from the date of

Page 10 of 88

~I

------------------------------------~---_._---~._---------

DG:DD/TxD/lOkW

/2011/EV /

receipt of last accepted consignment at site whichever is earlier shall be available free of cost to Doordarshan. Backward compatibility of the softw(lre must also be ensured for that equipment/item. (d) Any module/Assembly/Sub Assembly of the transmitter system or the power supply system failing during the guarantee period shall be repaired/replaced free of charge by the bidder at site. The transportation charges if any shall be borne by the bidder. Guarantee period of that module/ Assembly/ Sub Assembly would be extended corresponding to the outage period, if the repair/replacement of the failed item takes more than 30 days.

1.

DD will intimate the fault to the OEM or its authorised representative/dealer or local office/authorized representative/dealer of the bidder, who will deploy the staff at site within 3 days and attend the fault within a week. In case it is not possible to repair the defective unit/module at site, the above mentioned nodal office will provide the replacement to ensure the continuity of the service. In case the unit is to be sent to OEM for repairs, it has to be repaired and fitted back within 30 days of intimation of fault.

11.

111.

7. Maintenance support/spares

(a) The minimum recommended essential spares (like modules ofPA, Power Supply Modules or any other critical spares suggested by the OEM), required to maintain the continued service of transmitter in a reliable manner, shall be quoted separately by the supplier positively. (b) The minimum, recommended essential spares may be based on predicted rate of failure and requirement for three years. (c) The manufacturer shall also give a certificate attached with the offer to supply maintenance support and all spares during the lifetime of the TV Transmitter. The life of the TV transmitter should be certified, by' the manufacturer ..This is an essential requirement. The life of transmitter should be more than Ten years. (d) The bidder must also attach with the offer the certificates to supply all spares, installed softwares and software updates for providing maintenance support during the lifetime of all the input, monitoring and all other auxiliary items/equipment offered with the transmitter system. (e) The lifetime of all other major items such as measuring Equipment, UPS, AVR etc. must also be provided by the respective OEMs. (t) The maintenance support of each equipment/items/allied equipment supplied is to be ensured by the respective OEMs. Duly signed necessary certificates in this regard are to be provided by the respective OEMs only on their letter heads.

Page 11 of 88

, !\'!:

'

. DG:DD/TxD/10kW/2011/EV/

(g) In case the bidder quotes the optional items as "a set", the details of the components/items offered in the "set" must be spelt out clearly including their Model Nos. and quantity, failing which the tender is likely to be rejected. (h) The spares shall be treated as optional items, and the cost ,of spares ,shall not be taken into account while deciding the lowest bidder. (i) In addition, the bidder shall provide, in the following format, the address and contact information for after-sales-support of all· the equipment including all the third party bought out equipment that are to be supplied with the transmitter system as part of input, monitoring, measuring or allied equipment. of OEM Name Equipment with model No.

(1)

(2)

Authorization After sales & Name, by support office Telephone! Fax! the OEM for address Email of supply and after -concerned sales support of the personnel equipment (3) (4) (5)

.

8. Local Representative/Dealer

(a) Documentary evidence about local after sales and support arrangement as per Para 3(e & f) above for the transmitter system must,be. provided, with theoffer.'ITheaddress, contact details of local office/representative, details of technical staff, their qualification and experience etc. must be provided with the offer. (b) In case any item of transmitter system requires repairs at works/factory, the same would be handed over to local office /Representative/Dealer of OEM/bidder in India, who would arrange export of the item to works/factory and re-import in India after repairs. (c) After sales service and maintenance support of the transmitter should be available in India through the local office /RepresentativelDealer even after the guarantee period is over and throughout the life of the transmitter as certified by the OEM. (d) Copy of Agreement/ MoD signed in this regard between OEMs and their local representative/dealer must be submitted with the offer.

9. Training at OEM'sWorks (Optional)

(a) A proposal should be attached with the offer for training on operation & maintenance, installation and testing of the offered TV transmitter to six Doordarshan Engineers at Transmitter Manufacturer's works for 5 days. (b) The training programme will be structured so as to cover theory of operation Maintenance, Practical demonstrations of circuits, Maintenance demonstrations, Fault finding, Circuit Tracing exercises, Part Replacements, installation and testing of the offered TV Transmitters.

Page 12 of 88

DG :DD/TxD/IOkW /2011/EV /

(c) Two sets of training lecturers notes, schematic drawing, hand book etc. shall be supplied to DE (Transmitter Design), DO: DD also. (d) The offer shall include training fee only (To & Fro air fare, per diem, lodging, boarding charges etc. shall be borne be Doordarshan and are not to be quoted.) The cost of training shall be included in the optional items ofBOM.

10.Training at DD Sites

a.

A proposal for trainin'g for operation and maintenance of the transmitter equipment by the OEM expert, must be attached \\lith the offer for: . 1. 36 Doordarshan engineers (3 Engineers per VHF transmitter) in two batches, for one week each, at two DD sites. (The sites shall be decided by DD). 11. 12 Doordarshan engineers (4 Engineers per UHF transmitter) for a period of one week at one DD site. (The sites shall be decided by DD). b. The training shall cover theoretical concepts, demonstration of features, Software, Configuration of Transmitter units, operational & maintenance instructions, fault finding, circuit tracing, component/ module replacements, trouble shooting, preventive maintenance and other relevant topics etc. related to the transmitter. c. Training material in hard and soft copies are to be provided to each DD engineer undergoing the above training. d. Training at each site for operational staff: In addition, OEM(s)' representative(s) shall give ·one day training on operation and configuration of Transmitter System at each site after site acceptance test. e. Two sets of training lecturers notes, schematic drawing, hand book etc. shall be supplied to DE (Transmitter Design), DO: DD also. f. Training fee quoted by the bidder shall include all charges like training fee, travel, boarding, lodging and local transport charges for deputing the OEM expert(s). DD shall bear all touring expenses of DD engineers only deputed for training and the same is not to be included by the bidder in their offer. The training fee if any shall be included in the essential items of BOM for deciding lowest offer.

11.Inspection

(a) ATP: A copy of ATP (Acceptance Test Procedure) must be submitted by the bidder within one month of issue of Purchase order for approval by Doordarshan. ATP should describe the standard testing procedures and the details of test benches for carrying out measurement etc. for the offered transmitter, UPS and AVR. The test reports will not be treated as ATP. The respective OEMs only shall prepare the ATP for their product being offered. The ATP shall be approved by Doordarshan after necessary modifications if required. The approved ATP shall be sent back to the bidder and is to be used for inspection of transmitter, UPS and AVR by DD Engineer(s) at respeCtive OEM's works before dispatch of the equipment. 30% of the

Page 13 of 88

·

"".

i

;-, ····..· ,. _.,

j

,

·

i,

I,..

······.

'I

".,.

. ,'i ·· "

'.' , ..

,.

.

.

DG:DD/TxD/lOkW /2011/EV /

VHF and the UHF Transmitters will be randomly selected for inspection by two DD Engineers at OEM's works. (b) The bidder has to intimate DD for inspection and testing of the above equipment, at least six weeks in advance when the equipment are likely to be ready for inspection. Inspection period will be three days for each transmitter and three days each for UPS and AVR respectively. (c) The bidder shall quote inspection fees only in his offer excluding the expenditure for DD inspectors on To & fro airfare, per Diem allowances, lodging, boarding charges etc. which shall be borne by Doordarshan. The· inspection fee if any shall be included in the essential items ofBOM for deciding the lowest offer. (d) All other associated equipment, items and ..accessories,,,will be ,accepted on the basis of Original Equipment Manufacture's (OEM's) Test Certificates (as per DD Specification) duly signed and stamped on the letter head of the OEM, failing which Test Certificates will be considered incomplete and equipment offered by the firm is liable to be rejected.

12.Testing and Commissioning

at site: Site Acceptance Test (SAT)

(a) The transmitter system shall be installed by Doordarshan as per the instructions contained in the manufacturer's installation manual. DD will intimate the bidder when the installation of the transmitter system is completed, giving them three weeks time for completing travel formalities etc. The representative of Transmitter OEM shall visit each site for site acceptance test and commissioning. The testing and commissioning shall be completed within M 7 days at each site. (b) For this purpose complete SAT. Procedure will be prepared by the OEM/bidder in respect of transmitter system and the power supply system and shall be submitted for the approval by DD. The endurance test for each transmitter shall be part of SAT. The test procedure shall indicate full details of test set up and equipment required during the Acceptance Testing at the site. All the test equipment needed for site acceptance are to be arranged by the bidder. (c) The OEM's representative will examine transmitter installation for correctness. Thereafter, the 'First Power ON' at site of the entire system shall be done by the OEM's representative (s). However, if necessary, the OEM may include appropriate measure in the equipment to avoid any 'Power ON' before SAT. (d) The expenditure for OEM engineer(s), representative(s)on travel, lodging, boarding, daily allowances etc. for site acceptance testing shall be borne by the bidder.

13.80M (Unpriced)

(a) A detailed, complete Bill of material (BOM), exactly in the same format as in the price bid, shall be attached with the technical, bid leaving price column blank. (b) Make, model and quantity of each item must be mentioned clearly in the BOM. In case of 'set' complete details of all components that form part of set should be spelt out/clearly i.e. the details of the component/item offered in the set including their part no. and quantities must be mentioned clearly.

Page 14 of 88

~I

DG :DD/TxD/IOkW /2011/EV /

(c) The BOM is provided in Annexure IA for VHF Transmitter system and in Annexure 1B for UHF Transmitter system. ' (d) The bidder may quote for VHF/UHF or both systems. VHF and UHF Systems shall be ranked separately for deciding the lowest tender. (e) The offer without the complete BOM for quoted VHF/UHF transmitter system shall not be considered. (f) The bidder must quote all the items listed in "Essential items" as well as "Optional items" of the BOM.

14.

Local/remote

Monitoring and control Facility

(a) Each transmitter should have all provisions of local LCD display, keypad, panels etc. for local operation, monitoring/control. (b) All parameters and working status of modules specified in ParaU) (i to xxi) given below should be available for local monitoring. (c) Detailed information on the parameters and features available for local monitoring and Control of the transmitter is to be submitted with the offer. (d) The transmitter shall have Control/operation and monitoring of the parameters locally as well as at remote-location through web interface. (e) The Control/operation and monitoring Software would run on normal PC with Windows platform. (f) The transmitter should have a "WEB" GUIinterface using TCP/IP. Necessary Transmitter functions Control & monitoring shall be provided via the remote "WEB" GUI interface. (g) Full functional description alongwith diagrams, block schematics, flow charts, pictures of various screens etc. must be attached with the offer. This is a mandatory requirement. (h) Both the transmitters should be remotely as well as locally monitorable/operable individually. (i) Alarms and logging provision should also be available for logging events and faults for minimum 1000 logs. U) Remotely and Locally'Monitorable parameters': Following parameters of transmitter are to be made available for monitoring on the PC at the remote location as well as on local PC. Details about all the individual screens may.be provided with the offer. Forward vision RF power Reflected vision RF power Forward aural RF,P,QW~C!, ""., Reflected aural RF power Output Power of each PA Reflected power of each PA DC power supply voltages of each PA PA transistor/pallet currents for drivers

,',! ··

1. II. 111. IV.

v.

VI. Vll. VIl1.

.".* .... .-.

Page 15 of 88

-

------------------------------------

..

--------------

DG: DD/TxD/I0kW /2011/EV /

IX.

X. Xl.

XII. XlII. XIV.

XV.

XVI. XVII.

XV111.

XIX.

XX.

XXI.

PA transistor/pallet currents for intermediate stage PA transistor/pallet currents for final stage. PA heat sink temperature Status of exciter in circuit Exciter output power AGC level Coolant Temperature Status of pumps in circuit Status of heat exchanger Summary fault log Fault and interlock indication: exciter fault, High reflection/VSWR and indications. Alarms for PA's VSWR, Temperature, Exciter alarm Any other parameter which the manufacturer thinks essential for proper functioning of a remote Controlled/operated transmitter.

15.Software

(a) One set of Copies of all softwares used in the transmitter system should be provided in the form of CD besides being loaded in to the system. (b) All software licenses are to be provided to Doordarshan on perpetual license basis without specifying any time limit or without specifying any 'end of life' of any of the softwares supplied.

16.Input, Monitoring and Measuring Equipment Rack

(a) The equipment like IRD, 10x2 Audio-Video switcher, Waveform monitor, Colour Pattern Generator, and monitoring amplifier etc. should be installed in standard 19" wired rack(s). The TV Receivers need not be installed in Racks but should be provided with suitable stands. (b) An indicative Schematic is given in Fig.l.

17.Transmitter

System

The General features of transmitter system are as below: (a) The transmitters should be rugged, reliable, and stable in operation under Indian tropical conditions. The climate may vary from very cold to hot, humid and dusty. Specifications of the transmitters are given in this document. All equipment would be used for 24x7 continuous operations. (b) Transmitter output should be 3yg" EIA unflange copper. In case of Aluminium, suitable transfer coupler/rings to connect the output with the Copper rigid line should be supplied to avoid thermocouple effect. (c) The output of the 10 kW transmitter will be fed via 7 Port patch Panel either to duaI3yg"/4" Dia. R.F. Feeder Cable for 2x20kW Panel Type Antenna system or to dummy load.

Page 16 of 88

DG:DD/TxD/10kW /2011/EV /

(d) There should be provision of interlock between Transmitter and Antenna load/Dummy Load so that transmitter is switched ON only when either of the 'two loads is connected. (e) The offered Analog transmitters should have low level diplexing (Common Amplification). (f) There should be provision for setting the lower and upper limits for the Forward and Reflected Power. (g) A detailed block schematic diagram for the TV transmitter system with all its constituent items should be provided with the offer. (h) The power consumption of the VHF and the UHF Transmitters including the cooling system must be specified by the bidder. (i) The quoted transmitter system must conform to the latest international standards of safety and EMC or their equivalent standards. The conformation to such standards/equivalent standards (indicating Standard's name & Number) must be stated in compliance statement. Documentary evidence to establish the equivalence of the standards must also be provided with the offer. U) Environmental Regulation: In compliance of keeping green Environment, the Transmitter built with hazardous materials & use of Toxic substances will not be accepted. WEEE/ROHS (Waste Electrical & Electronic Equipment/Reduction of Hazardous substances) regulations shall be strictly adhered to.

18.Exciter System

(a) The Transmitter shall have its own synthesized exciter system in (1 + I) mode capable of operation in any channel (with off set facility) in the frequency range 174MHz to 230 MHz for YHF Transmitter and 470MHz to 862 MHz for UHF Transmitter. (b) The channel conversion within the band should be possible at site without any change of component except output Channel filter. (c) The exciter shall be modular, in design" 100% solid-state and self contained unit. (d) Each Exciter shall have its own DC power supply. (e) It shall have facility for correction of linear and non linear distortions added in the RF Path using Digital Signal Processing (DSP). (f) A detailed circuit diagram must be attached with the offer to confirm the availability of DSP in the exciter. ···,,,"·"''''''lJ '" ". . . (g) The methodology of correction of linear and non linear distortions shall also be explained in the technical manual of the exciter. (h) Exciters shall function in (1 + 1) configuration with necessary hardware and software control for auto changeover with suitable display system. (i) There should be provision for indication of alarms and warnings. U) The exciter must have provision for AGC for optimizing the output power In different operating conditions.

Page

17 of 88

.-

",

.,

· .' ·· ( ~, ·

· , f'

· , , t)

( .:I

r ' ··

.' .,~

I , , ·~ , ·

, ..·.

'

····

,

.

DG:DD/TxD/10kW /2011/EV /

(k) On reduction in output power of the transmitter the operation of exciter system should automatically change to MGC (manual gainsontro1)lnod~.to_ay'Qi.d ..overdriving of the PAs. (1) The Exciter shall be equipped with 101100 base T Ethernet interface and shall have remote control provision by SNMP or Web interface. 19. Power Amplifier System (a) The Power Amplifiers should be modular in design, low weight;. and power efficient and easily maintainable. (b) Each PA should have independent built-in SMPS (Switched Mode Power Supply) based power supply unit. The SMPS should have' adequate margins for satisfactory working under overloading. It should be able to handle the fluctuations in power supply voltage and frequency. (c) SMPS of the PA module shall also be protected against overload conditions, i.e., over temperature, over voltage, over current. (d) All PAs shall be fully broadband for operation in the frequency range 174MHz to 230 MHz for VHF Transmitter and 470MHz to 862 MHz for UHF Transmitter. (e) All PAs must be inter changeable to be 'usedat any position and to be used for any channel in the specified band of operation without change of any hardware/software in the transmitters of same make and model. (t) All PAs shall have protection against high SWR, Over current, Over voltage and Over temperature. Visual indication for above protections should be available in each power amplifier. (g) LOMaS/MaS devices of reputed manufacturers and based on latest technology shall be used in all power amplifiers. (h) Due to aging the bias current of the LDMOS/MOS transistors based on latest technology may drift away from the nominal level. Biasing circuit/LDMOS should take care of this drift. The Characteristic Datasheet of the LDMOS/MOS transistors based on latest technology from the manufacturer must be attached with the offer. (i) All PAs should be hot pluggable. Transmitter shall be capable to remain ON AIR with reduced power output without any break in service even if a PA/PAs have failed. Power reduction on failure of one PA and subsequently more than one PAs is to be specified by the OEM. ..' The RF pallets/RF Boards should be field replaceable without requiring major adjustments or alignment. (k) Even in the event of failure of some transistors of final stage of the PA, the PA module shall continue to operate at reduced power. (1) Each amplifiers path shall have its own variable gain RF corrector allowing individual adjustment of gain and phase or shall have provision of automatic gain and phase adjustment. (m) The PA shall employ linear and non linear corrections.

Page 18 of 88

U)

DG:DD/TxD/lOkW

/2011/EV /

The amplifiers path shall incorporate an automa~ic control circuit for automatic compensation for normal temperature verses gain variation of the amplifiers. (0) Each power amplifiers shall have its own circuit breaker to connect and disconnect it with the AC power line. (p) The cooling system of power amplifiers shall be designed such that the tubes and hoses connected with the pressure valves can be isolated, drained and removed without any waste of coolant. Preferably a manual valve should also be available besides automatic pressure valves. (q) There shall be provision for monitoring of Reflected power and Output power to assess the health and normal working of the PA Unit.

(n)

20. Liquid Cooling system

(a) The transmitter must have closed circuit liquid cooling system. Air cooled transmitter system is not acceptable. The cooling system must be provided by the OEM of the transmitter only. (b) The cooling system and heat exchangers must have adequate redundancy of pumps and fans with automatic changeover to make it fully reliable. Manual changeover should also be possible. (c) The detail of type of coolant used must be provided by the OEM of the transmitter. (d) Full required quantity of the spare coolant is also to be supplied with the system in addition to the filled up quantity for the transmitter. (e) A proper and professional coolant filling arrangement is also to be supplied with the cooling system. . (f) Particle filter, monitoring of temperature at inlet and outlet, flow sensors and pressure sensor should be provided. (g) All the essential tools required for installation and maintenance of cooling system must be supplied with the transmitter. (h) Tubes and Hoses on amplifiers etc. shall be of self locking type so that no liqu'id escapes during change over. (i) Outside temperatures:may vary from 0° C to +50° C. Heat exchanger and liquid coolant used must be compliant with these temperature variations. U) The dual pump system should be such that it should be possible to replace one of the two pumps while the transmitter is in operation. (k) Full detailed description of the system is to be provided with the offer. A typical diagram, showing details of liquid cooling system and heat balancing of transmitter system bringing out all special requirements, should be attached with the offer. (I) A typical layout showing the maximum permissible distance between the transmitter and the cooling system must also be provided with the offer. The necessary length of the pipes as per the maximum permissible distance must be supplied.

Page 19 of 88

-DG:DD/TxD/l0kW /2011/EV /

21. Upgradeability to DVB- T2 Transmitter

! '

i

(I';,'

:"

c'

J,

'

(a) The offered analog transmitter should be upgradeable to DTT (DVB- 1'2) (Digital terrestrial transmitter adopting DVB- 1'2 standards with all features as per ETSI document EN302755) Transmitter in future without change in the Power Amplifiers or Control Circuit. (b) Full technical details for upgradation of quoted analog transmitter as DTT (DVB- 1'2) transmitter along with the financial requirement for the upgradation must be furnished with the offer separately without which tender will be considered incomplete & is liable to be rejected. (c) This Up gradation cost will however not be counted for deciding the lowest bidder. Break up detail of the necessary items must be provided in the BOM as optional items. (d) The broad specifications of upgraded .analog transmitter to DVB- 1'2 DTT Transmitter are given below: Broad Specifications of DVB- T2 Transmitter: System Parameters Transmitter Power output To be specified by the OEM of the Transmitter 1. (after output BPF (DVB- (Should not be less than 6dB down the rated Analog Power) 1'2 critical mask)) Any assigned channel between 174 MHz to 230 MHz for Frequency Range 2. VHF Band III and 470 MHz to 862 MHz for UHF Band IVN) 7MHz/8 MHz Bandwidth 3. DVB-T2, compliant to EN 302 755 4. TV standard 5. Harmonic level (for all 60 dB below carrier level or better harmonics) 60 dB below carrier level or better Spurious emission 6. 7. Modulation Coded orthogonal frequency division multiplex (COFDM) having all modes of modulation and parameter options as per EN 302 755 Inter modulation products :S -35dB (with pre correction) at ± 4.2MHz W.r.t. Centre Frequency (before filter) 13 dB Max Crest Factor/PAPR --, MER at the input of ~33 dB critical mask Shoulder Level (before :S - 35 dB filter) (after According to DVB-T2 critical mask, as per ETSI/ITU Shoulder Level Standards. Necessary graph in support must be provided. critical filter)

Page 20 of 88

8. 9. 10. 11. 12.

22.

S. No. 1. 1.1 Parameter General Parameters A.C. input Power Supply Value

DG:DD/TxD/lOkW /2011/EV /

Technical Specifications for one 10 kW Analog TVTransmitter System

400 V ±100/0, 50Hz ± 2°1o three phase 4-wire / 230V single phase & power factor >0.9.

1.2

(a) Ambient Temperature For Parts of transmitters to be installed inside the Transmitter Hall. (b)F or Parts of transmitters to be installed outside. (c )For storage/transport. Relative Humidity

,

.,.,

5 to 45°C

o to 50°C o to 50°C

J

1.3 1.4 1.5 1.6

.....

"

, ~.! .' '

.· ~ · · .'.

,

1.7

1.8

Max Altitude TV Standard (a)Dimension of transmitter (L x B x H) (b) Dimension of Pump rack (L x B x H) (c) Dimension of Heat exchane;er (L x B x H) (a)Weight of transmitter (b) Weight of Pump rack (c)Weight of Heat exchanger Safety

Max 90% NC at 40°C . ',_. . ", ." .. , ... 1500M PAL: 625 lines, ITUR - B/G To be specified by the suppliers meters.

III

..

The be specified by the bidder in Kgs.

1.9

EMC

,.

,I

ti!'

'\"

'II

EN 60215/ EN 60950 or equivalent (with latest amendments) whichever is applicable. As per ETS 300447, EN 301489-1-14 or equivalent with latest amendments

i\

.,

\

2. 2.1

R.F. Parameters 1.0utput power Transmitter (Visual sync peak)

of

each

10 kW

Page 21 of 88

:\1'

DG:DD/TxD/lOkW /2011/EV /

At the output of band pass filter 2.Aural Power

2.2

Frequency Range of Transmitter -

2.3 2.4 2.5 2.6

Carrier frequency stability RF output impedance Harmonic level Spurious emission

2.7

Output Peak Power Stability (Black to white transition) Blanking Level Stability Incidental carner modulation (IMD) Inter modulation distortion for common amplification Type of Amplification Modulation phase

-FA}= Aural Power: -13dB, FA2= -20dB and -lOdB for Mono, W.r.t. Visual Carrier Power Any assigned channel of 7 MHz between 174MHz to 230 MHz for VHF and 8 MHz between 470MHz to 862 MHz for UHf<with facility of frequency offsefby ± 2/3 of line frequency ±150Hz over a period of three months 50 ohms with VSWR < 1.3 60 dB below carrier level 60 dB below carrier level and not exceeding 1 mW for VHF and 12 mW for UHF Transmitters Within± 2%.

\ t . .i,

1.1-1.L

__. __ .u.

Within ± 2.5%. Within ± 4° - 53 dB or better

2.8 2.9

2.10 2.11 3. 3.1 3.2 3.3 3.4 3.5

Common Amplification Video: Negative AM (C3F) with Colour PAL-B, Audio: FM (F3E) Sync 0.3V ± 6dB, video.0.7V 75 ohms unbalance (BNC) > 34 dB (Upto 5 MHz) As per Table 2

Video Parameters Video input Level Video input impedance Video input return loss Video Frequency response Random AM Noise (100kHz to 5MHz) RMS Value: Unweighted continuous Weighted continuous Periodic Noise/Hum

-52 dB (RMS) or better -60 dB (RMS) or better -46- dB (p-p)or better

Page 22 of 88

3.6 3.7

Waveform response:. 2T pulse Line Tilt Field tilt Filed T Non Linear Distortion at 4.43 MHz: Differential gain Differential phase Baseline distortion of 20T pulse Group delay without receiver precorrection and sound trap off (0 to 4.8 MHz) Audio Parameters Audio Input Level within 2.0% K-rating within 2.0% (1% K rating) within 2 % (1% K-rating) Within ±5% (at APL 50%) Within ±5° (at APL 50%) Less than 3% better than ± 50 nS

DG:DD/TxD/10kW /2011/EV /

3.8 3.9

4. 4.1 4.2 4.3 4.4 4.5 4.6 4.7

4.8 4.9

4.10

4.11

4.12 4.13

Audio Input & Impedance Audio Input Return Loss Audio Frequency Deviation (For 100% Mod.) Audio Modulation Capability Upto ±75kHz deviation Audio Carrier displacement at ± 50Hz (Max) 50 kHz deviation' AF Bandwidth With pre-emphasis 30Hz to 15KHz Without pre-emphasis 30Hz to 20KHz Audio Pre-emphasis 50 microsecond Amplitude Vs Freq. Response ± 0.5 dB between 30Hz for audio (with 50% modulation) Harmonic distortion (audio) ~ 0.5% within 30 Hz 100% modulation deviation. FM Noise (Unweighetd) Better than -60dB to 100% modulation (Weighted) -66dB or less AM Noise (without -45 dB or better ~ modulation) Synchronous AM Noise (with -40 dB or better 100% modulation) ...

"

-4dBm to + 1OdBm for ±50kHz deviation 2 Nos. & 600 Ohms balanced 30dB (between 30Hz to 15 kHz) ±50KHz nominal

to 15KHz

to 15KHz for l.e. 50KHz with respect

'.

';

,Ii

II

Page

23 of 88

l,:~

'1':

;t

"...--'-..

..

---------------------------_

_-~-~--

DG:DD/TxD/l0kW

/2011/EV /

Table 2 A mplI u d e V/ S f requency Response 0 fth e VISIOnt ransmi er: rt Freq. relative to carrier in :q~.i!~. (d,~) '" JA~!~,~J~t~t. :"11 . MHz maXImum Minimum -4.43 -30 -4.43 to -1.25 -20 -1.25 to -0.75 +0.5 -0.75 +0.5 -4.0 -0.5 +0.5 -1.5 o to 1.5 +0.5 -0.5 + 1.5 Reference +3.0 +0.5 -0.5 +4.43 +0.5 -0.5 +5.0 +0.5 -2.5 , -26, +5.5 -"

. ,."

."

,

, '1' ~ :..,.

i

23.Compliance Statement:

(a) The compliance statement for all the paras, sub-paras listed in these specifications, terms and conditions and all annexures is a mandatory and an essential requirement. (b) A Para by Para, compliance statement should be attached with the technical offer. The compliance for specifications of each item/equipment offered with the system must be provided by the respective OEMs only with all supporting documents and data sheets. (c) The compliance statements must be provided by respective OEMs only on their letter heads duly signed by the OEMs clearly indicating name & designation of the signatories. (d) The compliance statement should be countersigned by the bidder. (e) Any offer without proper compliance statement shall be rejected at the first instance without making any reference to the bidder. (D All the required technical literature/data sheets and other supporting documents to verify the parametric values shown in the compliance statement must be attached with offer. This is a mandatory requirement. (g) The compliance statement must be given in the following format only. Mere signing of DO Specs sheets shall not be treated as compliance statement.

Page 24 of 88

. items Para No. Of DD spec Quoted DD Spec. value & value and details, Details as per the data sheet of offered system. (2) (3) (1) The page· no. ,of the offer/Technical bid, where the informati on/ supporti ng document is available. (4)

DG:DD/TxD/lOkW

/2011/EV /

Compliance OR Deviation

Remarks

(5)

(6)

\

ti"! ,;

I '

\

\

\

\

\

\

\

\

\

Page 25 of 88

DG:DD/TxD/l0kW

/2011/EV /

ANNEXURE- fA

BILL OF MATERIAL FOR 10KW VHF Band ITEMS FOR ONE LOCATION

BILL OF MATERIAL FOR lOKW VHF Band III ANALOG TV TRANSMITTER

.,),\ ,-, .· co, · "

III TV TRANSMITTER

SYSTEM & STATION

SYSTEM & STATION

ITEMS

MAKE/MODEL

Qty

S. NO. DESCRIPTION ESSENTIAL ITEMS (FROM S.No. 1 to 18) (To be considered for determining the lowest Tender) 10 kW, YHF Band III Analog (common ISet amplification type) with 3'l8"EIA unflange complete output, upgradable to DYB· 1'2, Transmitter in all respect System as perDD specifications with all items required to complete the entire system, including: (a) Exciter system in (1 + 1) mode with control unit. (b) Liquid pump assembly including all pipes and accessories, alongwith spare coolant and coolant filling arrangement. (c) Heat exchanger unit. (d) Transmitter control unit with necessary software. (f) Power amplifiers with inbuilt power supply (g) Installation, Maintenance & Operational Manuals & test data (h) Extender module for PA. (i) Extender module for Exciter (j) Essential tools for installation and maintenance of cooling system (k) Any other item(s) to complete the transmitter

2. (a)

OUTPUT COAXIAL EQUIPMENT

(b)

DUMMY LOAD Forced air cooled, 10 kW RMS power, YHF Band III As per DD Specs Annexure II-I Broadcast Power Monitor, YHF Band III, with suitable line section and elements As per DD Specs Annexure II-2

INo

ISet

Page 26 of 88

(c) 7 Port Patch Panel with U Links, as per DD Specs Annexure I1-3 3.

DG:DD/TxD/10kW /2011/EV /

1 Set

INDOOR COAXIAL FEEDER COPPER COMPONENTS ONLY (AS PER THE ACTUAL INSTALLATION REQUIREMENT IN THE EQUIPMENT CONT AINER) as per DD Specifications given in Annexure 11-4 3 lis" EIA Straight Transmission Line Copper 3 Nos. Sections (VSWR<1.05) of length 6 M. 3 W' EIA 90 DEG. ELBOW UNFLANGED(VSWR<I.05) 15 Nos. Straight Coupling 3 ~" EIA (with inner and 30 Nos. outer conductor and two nos of hose clamps for each St coupling) (VSWR<1.05) Fixed Hanger Assembly 3~" EIA 10 No. 3 ~"EIA Flange to Non flange 2No. adopter(VSWR<I.05) INPUT & MONITORING EQUIPMENT (As per DD Specs Annexure NoII-S (A TO K) CONSISTING OF: 19" Standard Rack wired with ACB panel(Input 2Nos Rack and Monitoring) Video Equalizing.Amplifier. Gonsisting of: ... , ~ . Video equalizing amplifier with clamp 2Nos Mounting frame, looping inputs with and 2No extender card. Redundant power supply 2No lOX2 Audio, Video married switcher with redundant power supply and extender card consisting of: 10X2 Audio, Video married switcher, with I,' ISet redundant power supply, local Programmable Push Button and extender card Mounting tray for external power supply INo

,

(a) (b) (c)

(d) (e) 4. (a) (b)

I. 11.

111.

...

(c)

I.

II.

(d) (e) (t) (g)

AUDIO JACK P ANEL-(N/C) AUDIO PATCH CORD (2ft) VIDEOJAC,I(.p~~J?:!:-(~/<;:) 2X24 WITH 10 NOS (2ft) PATCH CORD Audio stereo Monitoring Amplifier 8 W with compatible loud speaker as per DD

2 Nos. IONos. ISet I Set

Page 27 of 88

-----------------------------------------------------------

.......

i·, Ii t-

P \!

_ ,1 '- _ ·· ,

DG:DD/TxD/l0kW

/2011/EV /

Specifications (h) Audio Distribution Amplifier housed in a suitable frame with redundant power supply & extender card Audio Processor Amplispeaker

. · _. ·· ~ ~ ~ ·. \ i..

j

2 Sets

.

~-

! i"-

~

~-

.--."

(i) (j)

INo INo INo 1 No. 2Nos 4Sets

5

(a) (b) (c) (d)

MEASURING & MONITORING

EQUIPMENT

Colour Test Pattern and Tone Generat,orAs per DD Specs Annexure No II-6 TV Demodulator As per DD Specs Annexure NoII-7 WAVEFORM MONITOR As per DD Specs Annexure No II-8 29" LCD TV Receiver with VHF IUHF PALBIG Tuner, AV input facility, Yagi antenna and twin RF cable for off Air RF Monitoring (Only Reputed Brand like Sony/Panasonic/Hitachi/Samsung/LG is to be quoted) VU Meter Assy, with Power Supply Unit etc complete As per DD Specs Annexure No II-9 R.F. Analyser As per DD Specs Annexure No II10 Audio Analyser As per DD Specs Annexure No II-II

MISC ITEMS FOR MON. & MAINTENANCE

(e) (1) (g) 6 (a) (b) (c) (d) (e) (1) (g) (h)

INo. I Set 1 No.

STEP ATTENUATOR (O-lOOdB) As per DD Specs Annexure No lI-l2A ATTENUATOR 3dB (N type) As per DD Specs Annexure No lI-l2B ATTENUATOR 6dB (N type) As per DD Specs Annexure No lI-l2B ATTENUATOR l2dB (N type) As per DD Specs Annexure No 11-12B REDUCER 3 1/8" unflanged to N Female As per DDS pees Annexure No 11-4 REDUCER 3 1/8" unflanged to 1 5/8" Female As per DD Specs Annexure No II-4 Connector N 'I' Male Connector N 'I' Female

lNo. lNo. lNo. lNo. 2Nos. ~Nos. 4 Nos. ~Nos.

Page 28 of 88

----

---"

---------------------.-----------

7 8 Additional PA Unit with Built in Power Supply

--

DG:DD/TxD/10kW /2011/EV /

1 No. 1 Set

9

(a) Computer with 600VA UPS and PrinterLaserjet as per DD Specifications given in Annexure 11-13 Fb) Rack mounted PC with foldable Display. 1. TECHNICAL MANUALS of all equipments provided as per BOM. (a) Two sets ofall.manuals per order for DGDD. (b) Two sets of all manuals for 5 Zonal Offices (NZ, SZ, EZ, WZ, NEZ) per order. (c) Two sets of all manuals for the station.

1 Set Total 36 Sets Per Order (VHF Tx system)

2.

Video DVD showing complete alignments, measurements, replacement of LDMOS etc. , a. Two sets for each station; b. Two sets for 5 Zonal Offices «NZ, SZ, EZ, WZ, NEZ) per order c. Two sets for the Dte.

Total 36 Sets Per Order (VHF Tx system)

10 11

12 (a) (b)

(c) (d) (e)

Professional IRD 'unit for (!) band/ 'Kif reception As per DD Specs Annexure II-14 ANY OTHER ITEM/ITEMS FOR ,.. _ COMPLETING THE TRANSMITTER SYSTEM UPS SYSTEM as per DD Specifications given in Annexure (See Note 2 Below BOM) UPS: 60 kVA, 3Ph, 415 V AC as perDD specifications Battery Bank: Set of 2 Volts MF VRLA Cells 't '" (20 year Float Life) ISMinute Back':up (Make Amara Raja/GNB/ Union/Exide) Interconnecting cables between UPS to Battery

! '..

2Nos ISet

11-15 Consisting of: 1 No. 1 set

1 t,

~ · I

. '\'

:'

I set 1 set 1 set

Page 29 of 88

Battery Racks, Interconnections and Accessories Operation & Maintenance Manual

....· j-!-'-iH'H-lf\-'-

.... - - ; '.'- .. -,.~._ ..i_-·-·-'-·DG:DD/TxD/l0kW/2011/EV/

(0

13

Input Isolation Transformer 75 KVA 75 kV A 3 Phase unbalanced AVR (with phase sequence reversal sensing and protection circuit) in Air cooled construction as per DD Specifications given in Annexure 11-16 Testing and commissioning (at site) of: Transmitter System with cooling system and remote/local monitoring and control system Input, Monitoring and measuring equipment Inspection (As per Para 11) of (a) Transmitter at OEM's Works and Factory Acceptance Test (b) UPS at OEM's Works and Factory Acceptance Test (c) AVR at OEM's Works and Factory Acceptance Test Test Jig for P A Module of VHF Transmitter I(Only for one site) Training at DD sites as per Para 10

..

1 No. 1 No.

..

_--- ~'-~~.~ ,~~~-,-_--..... ..... ..-

---

.' .

14

(a) (b)

15

1 Job

.

1 Job

...

- ....·

- ,-

- - -~ .

..

1 Lot

1 Lot 1 Lot

-- -".- - - .. - ..

16 17 18

-

..

- _-0-

1 No. 1 Lot

Any Other items to complete the commissioning (if any, breakup detail may be Igiven) OPTIONAL ITEMS (Not to be considered for Ranking) .

1

1 Job

......

.,.'

.. ,-- .

Hardware and Software for making the Transmitter operational as DVB- T2 Transmitter. Maintenance Spares for: a) PA module b) PA Power Supply module c) Exciter module d) Any other critical Spares as recommended by the Transmitter OEM e) Jigs for PA and Exciter Note: Please refer to Para 7 Training at Transmitter OEM's Works for six

.

1 Set * 1 Set *

2

3

1 Lot

Page 30 of 88

DG:DD/TxD/lOkW /2011/EV /

___

IEngineers for 5 Days.

*Notes:

1. In case the bidder quotes the optional items as "a set", the details of the components/items offered in the "set" must be'spelt out clearly indicating the make, model and quantity.

2. Item No. 12 (a to f) are to be supplied only at the following Locations:

S. No. 1. 2.

Station

Dibrugarh Tura Daltonganj Bhawanipatna Jaiselmer Vishakhapatnam Pune Bhuj

3.

4. 5. 6. 7. 8.

3.

Rest of the items of Essential Part of BOM are to be supplied at 12 VHF Locations.

Page 31 of 88

DG:DD/TxD/lOkW /2011/EV /

ANNEXURE-IB

BILL OF MATERIAL FOR 10KW UHF Band ITEMS FOR ONE LOCATION

BILL OF MATERIAL FOR lOKW UHF Band IVN ANALOG TV TRANSMITTER SYSTEM & STATION ITEMS

IV IV TV TRANSMITTER

SYSTEM & STATION

MAKE/MODEL

Qty

S. NO. DESCRIPTION.. " ESSENTIAL ITEMS (FROM S.No. 1 to 18) (To be considered for determining the lowest Tender) 10 kW, UHF Band IVIV Analog (common 1Set 1 amplification type) with 3lfs"EIA unflange complete in all respect output, upgradable to DVB- T2, Transmitter System as per DD specifications with all items required to complete the entire system, including: (a) Exciter system in (1 + 1) mode with control Unit. ,. "('(""1-",-,·" (b) Liquid pump assembly including all pipes and accessories, alongwith spare coolant and coolant filling arrangement. (c) Heat exchanger unit. (d) Transmitter control unit with necessary software. (f) Power amplifiers with inbuilt power supply' (g) Installation, Maintenance & Operational Manuals & test data (h) Extender module for PA. (i) Extender module for Exciter. 0) Essential tools for installation and maintenance of cooling system (k) Any other item(s) to complete the transmitter OUTllUT COAXIAL EQUIPMENT ...'. ... 2.

(a)

(b)

DUMMY LOAD Forced air cooled, 10 kW RMS power, UHF Band IVIV As per DD Specs Annexure II-I Broadcast Power Monitor, UHF Band IVIV, with suitable line section and elements As per DD Specs Annexure II-2

INo

ISet

.

Page 32 of 88

DG:DD/TxD/l0kW

/2011/EV /

(c)

7 Port Patch Panel with U Links, as per DD Specs Annexure II-3.

.

I Set

3.

INDOOR COAXIAL FEEDER COPPER COMPONENTS ONLY (AS PER THE ACTUAL INSTALLATION REQUIREMENT IN THE EQUIPMENT CONT AINER) as per DD Specifications given in Annexure 11-4

""

.

(a) (b) (c)

(d) (e) 4. (a) (b)

1. 11.

Ill.

...

(c)

1.

11.

3 lis" EIA Straight Transmission Line Copper 3 Nos. Sections (VSWR<1.05) of length 6 M. 3 1jg" EIA 90 DEG. ELBOW UNFLANGED(VSWR < 1.05) 15 Nos. Straight Coupling 3 1jg" EIA (with inner and 30 Nos. outer conductor and two nos of hose clamps for each St coupling) (VSWR<1.05) Fixed Hanger Assembly 3 1jg" EIA 10No. 3 1jg" EIA Flange to Non flange 2 No. adopter(VSWR<1.05) INPUT & MONITORING EQUIPMENT (As per DD Specs Annexure NoII-S A TO K) CONSISTING OF : 19" Standard Rack wired with ACB panel(Input 2Nos Rack and Monitoring) Video Equalizing Amplifier consisting of: Video equalizing amplifier with clamp 2Nos Mounting frame, looping inputs with and 2No extender card. Redundant power supply 2No lOX2 Audio, Video married switcher with redundant power supply and extender card consisting 'of: ,'", I ,"'" 1OX2 Audio, Video married switcher with lSet redundant power supply, locall~rogrammable, Push Button and extender card Mounting tray for external power supply lNo

"

.'.

,

I

(d) (e) (f) (g)

AUDIO JACK PANEL-(N/C) AUDIO PATCH CORD (2ft) . t , · , .. . '" , VIDEO JACK PANEL-(N/C) 2X24 WITH 10 NOS (2ft) PATCH CORD Audio stereo Monitoring Amplifier 8' W with' compatible loud speaker as per DD

2 Nos. 10Nos. lSet lSet

Page 33 of 88

_________________________________

c

_

i

i

i

1 (

DG:DD/TxD/10kW /2011/EV /

(h)

(i)

U)

5

(a) (b) (c) (d)

Specifications Audio Distribution Amplifier housed in a suitable frame with redundant power supply & extender card Audio Processor Amplispeaker

!,l I'

!

2 Sets

.

..

-

'"

-.-

--,-

-.-.-.--

INo INo INo I No. 2Nos

MEASURING

& MONITORING

EQUIPMENT

Colour Test Pattern and Tone Generator As per DD Specs Annexure No 11-6 TV Demodulator As per DD Specs Annexure NoII-7 WAVEFORM MONITOR As per DD Specs Annexure No II-8 29" LCD TV Receiver with VHFIUHF PALBIG Tuner, A V input facility, Vagi antenna and twin RF cable for off Air RF Monitoring (Only Reputed Brand like Sony/Panasonic/Hitachi/Samsung/LG is to be quoted) VU Meter Assy, with Power Supply Unit etc complete As per DD Specs Annexure No 11-9 R.F. Analyser As per DD Specs Annexure No II10 Audio Analyser As per DD Specs Annexure No II-II

._ I -,; " ~ ., .

,.

4Sets

(e) (f)

--

-.-

INo. I Set I No.

(g)

6 (a) (b) (c) (d) (e) (f)

MISC ITEMS FOR MON. & MAINTENANCE

(g)

(h)

STEP ATTENUATOR (O-100dB) As per DD Specs Annexure No 11-12A ATTENUATOR 3dB (N type) As per DD Specs Annexure No 11-12B ATTENUATOR 6dB (N type) As per DD Specs Annexure No 11-12B ATTENUATOR 12dB (N type) As per DD Specs Annexure No 11-12B REDUCER 3 1/8" unflanged to N Female As per DDS pees Annexure No 11-4 REDUCER 3 1/8" unflanged to 1 5/8" Female As per DD Specs Annexure No II-4 Connector N '1' Male Connector N 'I' Female

INo. INo. INo. INo.

"

2Nos. 2 Nos. 4 Nos. 4 Nos.

Page 34 of 88

7 8 Additional PA Unit with Built in Power Supply' Computerwith 600V A UPS and Printer-Laserjet as per DD Specifications given in Annexure 11-13 (b) Rack mounted PC with foldable dis la TECHNICALMANlJALSof aU equipments provided as per BOM. (a) Two sets of all manuals per order for DODD. (b) Two sets of all manuals for 2 Zonal Offices (NZ, EZ) per order. (c) Two sets of all manuals for each station. Video DVD showing ~omplete alignments, measurements, replacement of LDMOS etc. (a) Two sets for each station, .'. '. (b) Two sets for 2 Zonal Offices «NZ, EZ) per order (c) Two sets for the Dte. 10 11 12 (a) (b) ProfessionaIIRD'unitfodDbandl'Ku'reception' As er DD S ecs Annexure 11-14 ANY OTHER ITEM/ITEMS FOR. COMPLETING'THE SYSTEM UPS SYSTEM as per DD Specifications given in Annexure UPS: 60 kVA, 3Ph, 415 V AC as per DD s ecifications '" "'''.'!''.' .. ,'.'1."" Battery Bank: Set of 2 Volts MF VRLA Cells (20 year Float Life) 15 Minute Back-up (Make Amara Ra'a/GNB/ Union/Exide Interconnecting cables between UPS to Battery Battery Racks, Interconnections and Accessories Operation & Maintenance· Manual Input Isolation Transformer 75 KVA (a)

DG:DD/TxD/10kW /2011/EV /

1 No.

1 Set

1 Set otal 12 Scts Per Order (UHF Tx system)

9

otal 12 Scts Order (UHF system)

Pcr Tx

Nos ISet 1-15 Consisting of: 1 No, 1 set

(c) (d) (e)

(f)

1 set 1 set 1 set 1 No.

Page 35 of 88

'.:

F'~,\.:,:·:: .·......'"

'.

,

"

.... :..Ll~~Lui

;_

_

~

__

O<;i_:PP/TxD/l0kW /2011/EV /

13

14 (a) (b) 15

75 kV A 3 Phase unbalanced AVR (with phase sequence reversal sensing and protection circuit) in Air cooled construction as per DD Specifications e:iven in Annexure 11-16 Testing and co~missioning (at site) of: - .:.---Transmitter System with cooling system and remote/local monitoring and control system Input, Monitoring and measuring equipment

:

1 No.

---...,....

.

- ._._-~_ ----. ..·....----.-------....

--_.-

1 Job 1 Job 1 Lot

,-'-"

16

17 18

Inspection (As per Para 11) of (d) Transmitter at OEM's Works and - ._--._~>.- - - "--'--, ~~.-. _ _----__ Factory Acceptance Test -_. (e) UPS at OEM's Works and Factory Acceptance Test AVR at OEM's Works and Factory (f) Acceptance Test Test Jig for P A Module of UHF Transmitter (Only for one site) "---_ '.- -0Training at DD sites as per Para 10 ..

.. ....

.. --,--

-_

..

-~

1 Lot 1 Lot 1 No. against the order 1 Lot 1 Job

..

._

·.··

->- ·· _.,._---_.,.~

·······

O~

Any Other items to complete the commissioning (if any, breakup detail may be e:iven) OPTIONAL ITEMS (Not to be considered for Ranking) 1 Hardware and Software for making the Transmitter operational as DVB- T2 Transmitter. Maintenance Spares for: f) PA module g) PA Power Supply module h) Exciter module i) Any other critical Spares as recommended by the Transmitter OEM j) Jigs for PA and Exciter Note: Please refer to Para 7. Training at Transmitter OEM's Works for six Engineers for 5 Days.

-

1 Set * 1 Set *

2

---

3

1 Lot

Page 36 of 88

* Notes:

DG:DD/TxD/10kW /2011/EV /

1. In case the bidder quotes the optional items as "a set", the details of the components/items offered in the "set" must be spelt out clearly indicating the make, model and quantity. 2. All of the items of Essential Part of BOM are to be supplied at 3 UHF Locations.

"

Page 37 of 88

...

,.

1/

;l \

.·· ,

"'!

!

I

··

'I I 'I iI

,

i l'rH l"'l! DG:DD/TxD/10kW/2011/EV

/

Annexure 11-1

"':)

Specifications of 10 kW dummy load

.

1. Introduction: One numqer 10 kW air cooled Dummy Load of 50 Ohm is required. 1.1 Low maintenance and high reliability.' '. , 1.2 Fully shielded against the production of extraneous radiation. 1.3 Manual/Automatic fan modes. 2. Technical specifications: S.No. Description Power Rating Connector Frequency Range Technical Specification 10k W continuous RMS power 3ljg" EIA UnFlange 174MHz to 230 MHz for VHF Transmitter 470MHz to 862 MHz for UHF Transmitter :::;1.10:1 50 Ohm Nominal Forced Air cooled Single Phase, 230 volts ± 10%, 50 Hz± 2% O°Cto 50°C 5°C to 45°C Max 90% NC at 40°C To be provided by the bidder. To be provided by the bidder.

2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12

.

and

VSWR Impedance(N ominal) Type of Cooling AC Power Temperature of Storage Temperature of Operation Humidity Dimensions: (Length x Width x Depth) in mm. Weight (in kg)

Page 38 of 88

-------------------------------

..--

-'''.''-'-.

DG:DD/TxD/lOkW

/2011/EV /

Annexure 11-2 Specifications of 10kw Broadcast Power Monitor (Through Line Power Meter):

1. Introduction: 1.1 Broadcast Power Monitor, VHF Band III or UHF Band IV/V, with 3 lis" EIA un flanged line section and suitable elements for measurement of Maximum Forward power of 10 kW and reflected power of 1.0 kW, VSWR, Return Loss etc. 1.2 Ethernet & RS 232 enabled- Remote monitoring, control & instant alarm alert with 50 feet of cable to connect RS 232 and serial port between monitoring unit and line section, and serial interface cable. 1.3 Data logging capabilities - System trends and anomalies before failure. 1.4 Integral RF Test Port facility. 1.5 Frequency/Channel field configurable. Techn' Ica I speci'fi fIOns: Ica S,No, Description a. b. c. Accuracy Connector Frequency Range

Technical Specification ± 5% of reading 3yg" EIA UnFlange 174MHz to 230 MHz for VHF Transmitter and 470MHz to 862 MHz for UHF Transmitter < 1.10:1 ., '50 Ohm Nominal No/Low Forward power, High forward power, VSWR Single Phase, 230 volts ± 10%, 50 Hz± 2% O°Cto 50°C 5°C to 45°C Max 90% NC at 40°C 1500 Meter. Broadcast power

~

d. e. f.

VSWR Impedance(Nominal}' Alarms

g.

AC Power

h.

1.

Temperature of Storage Temperature Operation Humidity Max Altitude Display of

j.

k. 1.

...

Page 39 of 88

"'"

''-,-:''

)

'-';

-------------------------------------

-

---------

DG:DD/TxD/10kW /2011/EV /

m. n.

o.

Coupler Directivity Dimensions: (Length x Width Depth) Weight

monitor should display on screen Fwd Power, ref power, VSWR, Return Loss (as mentioned in 1.1 above) 28dB minimum To be specified by the x bidder in mm To be specified by the bidder in kg

Page 40 of 88

DG :DD/TxD/lOkW /2011/EV /

Annexure 11-3 Specifications of Seven Port Patch Panel

S.No. Parameter Specification 174MHz to 230 MHz for VHF Transmitter and 470MHz to 862 MHz for UHF Transmitter ~ lOkW/~ 20kW 3~" SOCto 4SoC

1.1

FREQUENCY

RANGE

1.2 1.3 1.4 1.S 1.6 1.7 1.8 1.10 1.11

INPUT /OUTPUT POWER INPUT / OUTPUT PORTS OPERATING TEMPERATURE

RANGE

Max Altitude

ISOLATION TO UNUSED PORT INPUTVSWR INSERTION LOSS Forward and reflect power monitoring Input, Output, U-Link, Inner Lines

1500 Meter.

~ 60dB ::; 1.05: 1 ::; 0.1 dB To be included in the offer 31Js" unflanged U links - (Cu Rigid Lines only)

system

Functions:

1. The 7 Port Patch Panel should accept the output of any VHF /UHF TV channel between frequency range 174MHz to 239 MHz for VHF Transmitter and 470MHz to 862 MHz for UHF Transmitter and routeth{power to the antenna or the dummy load. 2. It should provide transmitter interlocks for operational safety. 3. The schematic drawing shown in Fig. 3 must also be referred for details of U-Links, Power handling and the connections. 4. There should be provision for forward and reflected power monitoring for the transmitter. 1. The system should be compact in design, should be easy for installation and must require minimal maintenance. 2. The 7 port patch panel shallrbeverticallymountable on floor so as to occupy minimum space. 3. The U links provided should be easily removable and reconnectable requiring minimum efforts. They should have proper gripping, locking and unlocking facility.

Page 41 of 88

,I

DG:DD/TxD/10kW /2011/EV /

Annexure 11-4 Specifications of Indoor Coaxial Feeder Cu Components:

1. Introduction:

1.1 All the indoor coaxial feeder components must be of high quality copper, used for broadcasting system for a good transmission performance. 1.2 The VSWR of all coaxial feeder components must be less than 1.05. 1.3 There should be a firm grip between various coaxial feeder components. 1.4 All the components should be capable of handling the power supplied at the output of the transmitter. 1.5 Spacers must be used at a suitable length between inner and outer conductor.

Page 42 of 88

-.

Specifications of Input, Monitoring equipment and Racks:

DG:DD/TxD/I0kW

/2011/EV /

Annexure II-S

A. Specifications of Standard 19" Rack: i) The input and monitoring rack should be suitable for: Feeding video and stereo/mono audio programmes to TV transmitters & ii) Metering/monitoring of different programme input sources as well as signal at intermediate points in the audio/video chain and also demodulated signals.

Detailed specifications of rack and individual 1.0 GENERAL DETAILS:

equipment

are given below.

1.1 Complete equipment wiring and other details are to be worked out by the bidder. The details of equipment to be installed in this rack is to be provided by the bidder. 1.2 All audio/video lines from the Jacks & Equipments are to be connected to a terminal block to be located near the bottom of the rack for external feeding of cables by the indentor. All the equipment are to be properly earthed with the existing equipment earthing system in the transmitter hall. 1.3 RFI/EMI filter should be provided at mains input of the rack as per relevant provisions of FCC rules and regulations, or equivalent standards for effective rej ection of the interference from the high power transmitters operating in the premises. These racks will be used in High Power Transmitter halls/container i.e. the rack with full complement of equipment has to operate in a high RF field. As such all the specifications of the individual equipment as well as the full chain, are to remain valid in high RF fields. .

2.0

EQUIPMENT

RACK:

The standard 19" rack will have various equipment. The frame of the rack should be of high quality extruded aluminium or high grade steel material as per relevant material codes. The aluminium profiles should be either anodized or powder coated and the steel parts should be enamelled to give pleasing and aesthetic look ;and.superior\andJong..lasting ,paint finish. The rack is to be of sturdy design. The width should be suitable for mounting of standard 19" equipment. Doors should be provided on the rear side and should have louvers and exhaust fan to facilitate proper ventilation. The overall size of rack should be 2000 (H) x 545 (W) x 600 (D) mm. 2.1 Input/Output Isolation 90 dB 2.2 Input/Input Isolation 90 dB B. Specifications of Video Equalizing Distribution Amplifier: 1. The system should be high-performance, having high reliability of professional quality, analog video equalizing distribution amplifier. 2. It should have high quality'mounting frame for mounting it in standard 19" rack. 3. It should be capable of amplifying composite and component analog PAL signals, with or without sync and subcarrier signal. 4. The amplifier must have adjustable gain in the range ± 3dB.

Page 43 of 88

-----------------------------------.-----......--

\"

1/

;

DG:DD/TxD/10kW/2011/EV/

5. The amplifier should have at least 8 outputs and one differential input. 6. It should have redundant power supply. 7. Tcchnical ParametersSr. No. 1. 2. 3. 4. 5. 6. 7.

8.

9. 10. 13.

Description Power supply Operating Temperature Input level Input Impedance Input coupling CMRR Input Return loss Output Isolation Frequency Response Equalizing Response SIN ratio

\ ! 1I \.,' Parameters 230VAC±10%, 50Hz ± 2%. 5°C to 45°C 1 V p-p nominal 750 DC >65 >45dB >40dB ± 0.05dB (DC to 10MHz) ± 0.05dB (DC to 5MHz) >70dB

i'

I ,

c.

Specifications of Video Audio Switcher

1. The Video Audio switchers should c~~~ist,,9fa .v.i4~0 switching module & audio switching module with a Control logic board for audio to follow video operation with basic configuration of 10 inputs and 2 outputs (lOx2) with integrated redundant power supply. 2. Buttons per cross point Control lines should be available to permit Control from front panel through illuminating momentary push button. 3. Switching should be selectable between instantaneous (non vertical intervals) or as vertical interval reference. 4. The audio, video and power supply connection should be on the back side of the unit. The switcher should have following technical specifications. S. No. 1. Description Standard Video inputs No. Of inputs Input signal level Input impedance Rcturn loss Specification PAL colour standard 10 Nos. with loop through facility IV p-p nominal (CCVS) High impedance for loop through inputs, terminable into 75 Ohms through termination plug. Better than 40dB upto 5 MHz, across 75 Ohms

Page 44 of 88

2.0

2.1 2.2 2.3 2.4

DG:DD/TxD/l0kW

/2011/EV /

3.0

3.1 3.2 3.3 3.4

Video outputs No. of outputs

4.0

4.1 4.2

Output signal level Output 75 Ohms Unbalanced impedance Isolation Better than 35 dB between buffered output Video Performance Gain Unity, ± 1.0 dB adjustable(internally) Frequency ± O.ldB from DC to 5 MHz ± 0.5 dB from 5 MHz to 8 MHz response Differential Gain Differential Phase Line frequency tilt Field frequency tilt Signal to noise ratio Cross talk Connectors Audio inputs No. of inputs Inputs signal level Input impedance Input connector Audio outputs No. of outputs Output signal level Output impedance Better than 0.3% Better than 0.3 deg 0.5% 0.5% Better ··than :75: :dB· (weighted) at rated input & output levels Better than 60 dB referenced to 1Vp-p at 5 MHz BNC ( for inputs & outputs) ION os balanced +8dBm nominal, +20 dBm maximum at 600 Ohms

,., ,\.t

a)2 (Two)buffered output b) 2 for monitor bus IV p-p nominal (CCVS)

4.3 4.4 4.5 4.6 4.7 4.8 4.9

5.0

5.1 5.2 5.3 5.4

i.,

I!

\.

,l

!t

j

~ I...

" .

,

,.

...

,

600 ohms, Balanced XLR female 2 (Two) for program & 2 for monitor bus +8 dBm nominal 600 Ohms balanced

6.0

6.1 6.2 6.3

Page 45 of 88

DG:DD/TxD/10kW /2011/EV /

6.4 7.0 7.1 7.2 7.3 7.4 7.S 9.0 9.1 9.2 9.3 9.4 9.S 9.6

Output XLRmaie 1 \ ! ' connectors Audio Performance Gain Unity, ± I.SdB adjustable ± 0.1 dB (20Hz to 20KHz) Frequency response Cross talk Better than 70 dB (20 Hz to IS KHz) Signal to noise 90 dB referenced to +8dBm ratio Better than 0.1 % (20Hz to 20KHz at +20dBm) Harmonic .distortion General Operational on both 24 Vdc and 230 Vac +/- 10% , SO Power supply Hz±2% SOCTo 4SoC Operating temperature 0° to SOoC Storage I~.~ l t. t + (, i.,~' . temperature Max 90% at 40° C (non condensing) Relative humidity Height to be specified in RU for 19" rack Dimensions Push button Control on front panel Control

'II i \

! ~I

'

'

r

~

;

i

;1

. , \ , ~.

I 1

I

If"

'-,

; _1 t

'~~ ~

·....

'I'

I I \ ; ~ \.:

I',,'..

,~

.,.

D. Specifications

of Audio Jack Panel-eN/C) 2x24

The jack strips of 20 points each must be of high quality with positive contact and of twin type for stereo/mono signals. All the contacts should be silver plated. E. Specification of Video Jack Panels: The jack strips of 20 points each must be of high quality. All the contacts should be silver plated.

F. Audio Patch Cords (2ft)

10 nos. of stereo patch cords are to be provided for patching purposes. Their length is to be 2 ft. and should be of high quality, durable audio cable and jacks and should be matched with AF jack panel.

Page 46 of 88

------------------

..

_._----~ ----~---------------------

G. Video Patch Cords (2 ft) H. Specifications of Audio Stereo Monitoring Amplifier 8 W

1.0 TECHNICAL SPECIFICATIONS: The amplifier should essentially have the following features:

DG:DD/TxD/lOkW

/2011/EV /

10 nos. of video patch cords are to be provided for patching purposes. Their length is to be 2 ft. and should be of high quality, durable video cable and jacks and should be matched with video jack panel.

Protection against current over-loads: The amplifier output should get muted in case of overload and revert to normal functioning once overload ceases to exist.

1.1

1.2 Protection against thermal overload: Temperature of power pack and heat sinks of both channels should be monitored and the amplifier should get muted with a visual indication whenever temperature exceeds permissible limits. In case of excessive temperature of heat sinks, the amplifier should be protected. 1.3 Monitoring amplifier output should be continuously monitored for DC components or very low frequency components which might endanger speakers if present for longer durations. Amplifier output should get blocked in such an eventuality. 1.4 The amplifier should have protection frequencies and high RF fields. 1.5 against open circuit, full short circuit, ultrasonic

It should be switchable to stereo and dual mono operating modes.

1.6 Necessary function switches such as volume/gain control, low and high filters should be available on front panel. These controls should be rugged and reliable. S.No. TECHNICAL PARAMETER INPUT No. of input (stereo) Input level Input impedance CMRR (20 Hz-20 kHz) SPECIFICATION

i

1.1 1.2 1.3 1.4 1.5

i

'"il

.· "

,

!

,

t-.

,,1

,

·1

.

1 set (2 mono) .(XLR female connectors) -10 dBu to + 10 dBu for rated output. > 10k ohms (balanced) >60dB

Page 47

of 88

DG:DD/TxD/l0kW

/2011/EV /

i

I \l'

'i.

I

I

·

);.

ii'

2 2.1

Power Output Frequency Response With reference to 1 kHz over the entire range of 20 Hz to 20 kHz. Total Harmonic Distortion at 1 kHz. Signal -to-noise-ratio With input shorted and at rated output (unweighted nns) at .dBu input (22 Hz-22 kHz) Damping factor Power supply

8 W rms (40 W peak music power) per channel at 8 ohms nominal impedance at suitable terminals. ±0.5 dB

j

1: ~'. ( \'

" 1 1"

1

'

,!;

0" ·

,

!

2.2 2.3

.:~::Q:5% rated output at

85 dB or better.

!

,.;1

.' .....

',

': .1·"

,

:"

2.4 2.5 2.6 2.7 2.8 2.9

>75 into 8 ohms at < 1 kHz The amplifier shall work on 230V ± 10%, 50Hz ±2% sing'fe'phaseACsupplY.-''''''''

",'C"

Level difference between the Equal to or less than 0.5 dB channels Phase difference between the < 10°,20 Hz to 20 kHz channels Inter-channel X-Talk at 15 >75 dB at nominal level kHz Accessories: All necessary accessories like power cord and mating connectors shall be supplied along with the units. The standard accessories should be clearly mentioned in the quotation. Also, optional accessories if considered useful/recommended by the supplier should be quoted separately. MECHANICAL: The amplifier should be 19" rack mounting type for mounting in a rack.

I. Specifications

3.

of Audio

Distribution

Amplifier

with

Suitable

Frame

and

Redundant Power Supply and Extender Card 1. The system should be high-performance high reliability, analog audio distribution amplifier. 2. It should be of professional quality. 3. It should have flat frequency response, a controlled roll-off and very low distortion. 4. The Isolation between the modules must be better than 90dB for audio frequency band. 5. The amplifier should be configured to 8 outputs designated to one input. 6. It should have balanced input and output.

Page 48 of 88

erature Parameters 230YAC±1O%, 50Hz±2%. 5°C to 45°C 28dBu (Maximum) 660 25dBu (Minimum) >85dB >85dB isolation >70dB ±0.05dB (20Hz to 20KHz) -90 to 30dB in 0.5dB ste s >90dB

DG:DD/TxD/10kW /2011/EV /

onse

J. Specifications for Audio Processor

1. Introduction:

a. It should be a high quality stereo/dual mono audio processor for Analog television audio, but should have digital signal processing only. b. The equipment should be rugged, reliable and stable in operation under Indian tropical condition. The climate may vary from very cold to hot, humid & dusty. c. It should provide sound with good loudness control at it's output as well as preserve the frequency balance of original sound while controlling subjective loudness . d. It has to process audio available in the transmitter from a professional IRD (Satellite receiver) or a T.Y. studio. e. LCD/LED type meters on front panel for adjustment of parameters as well as for displaying required parameters for monitoring. f. It should be a stand alone unit with built in tone generator for standard audio test tones upto 15kHz. g. As the audio processor will be installed in very high R.F. field environment of 10kW UHF T.Y.Transmitters, it should have proper R.F. Shielding. h. It must have Stereo Enhancement, Equalization, and AGC with look-ahead peak limiting.

. . ". . . _ ··. '_ .", I..}\ ...·...

1.

It must have Stereo Enhancement, Equalization, and Multi-Band processing (at least 5 Band, including AGC) without look-ahead peak limiting.

J. The bypass test facility of the unit must be available. k. The detailed technical specifications are provided below:

-':.

Page

49 of 88

DG:DD/TxD/l0kW

/2011/EV /

2. Technical Specifications

of Audio Processor:

(a) Analog Audio Input

1.

Configuration:

Stereo / Dual-Mono.

11.

Impedance: > 10k .0 load impedance, electronically balanced. Nominal Input Lcvel: Software adjustable from -4.0 to + 13.0 dBu (VU). Maximum Input Lcvel: +27 dBu. Connectors: Two XLR-type, female, EMI-suppressed. Pin 1 chassis ground, Pins 2 (+) and 3 electronically balanced symmetrical. Processing: Digital Signal Processing (DSP). - . Filtering: RFI filtered. (b) Analog Audio Output

" ,~ '"' (, "t ':'-'

fl'

111.

IV.

v.

VI.

"I

V11.

1.

Configuration:

Stereo, Flat or pre-emphasized at 50 ~s. 600 .0, balanced or unbalanced. Adjustable from -6 dBu to +24 dBu peak, into 600

11.

Load Impedance:

111.

Output Level (100% peak modulation): ohm, software adjustable.

IV.

Signal to Noise Ratio: 2: 90 dB unweighted (Bypass mode de-emphasis ed, 20 Hz-IS kHz bandwidth, referenced to 100% modulation). L/R Crosstalk: ~ -70 dB, 20 Hz-IS kHz. Distortion: ~ 0.0 I% THD (Bypass mode, de-emphasised) 20 Hz-IS kHz bandwidth. Connectors: Two XLR -type, male, EMI-suppressed. Pin 1 chassis ground, Pins 2 (+) and 3 electronically balanced, floating and symmetrical. Filtering: RFI filtered.

Page SO of 88

v.

VI.

V11.

VIlI.

------------------------------------------------

.,-.

DG :DD/TxD/lOkW /2011/EV /

3. General Parameters

I.

Input Voltage: Single phase, 230Volt ± 10%, 50 Hz ±2%. Input Power Connector: IEC, EMI-suppressed. Detachable 3-wire power cord supplied.

¥.-,

11.

lll.

Grounding: Circuit ground should be independent of chassis ground, and can be isolated or connected. Safety Standards: As per latest international standards. Operating Temperature: 5°C to 45°C for all operating voltage ranges.

IV.

v.

VI.

Humidity: 90% (max) at 40% non-condensing: Mounting: 19" Rack mounting, height must be specified by bidder in RU. RFI/ EMI: According to latest International standards. Weight: Must be specified by bidder in Kg.

'i.

V11. Vlll.

IX.

~'! t ',t ..·.·..

I i I

\'

\;

(

t

\;

t I ,.:

K. Specification of Amplispeaker

1 2 3 4 The system should be high grade transducer of professional audio monitoring quality. Unit must have an ON/OFF switch with LED indication and a level control. Transducer components like Woofer and Tweeter must be magnetically shielded. Technical SpecificationsSr. No. 1. 2. 3. 4. 5. 6. 7. Description Power Supply Amplifier power without clipping SIN ratio Gain control range Volume control range CMRR Protection Parameters 230VAC±10%, 50Hz ±2%. LF-45W, HF-45W >90dB ±6dB >70dB >65dB Over current, Over heat, RFI, Switch On/Off transients.

Page 51 of 88

'Il."~'

otC

, ( · 1 ,", I

DG:DD/TxD/lOkW /2011/EV /

Annexure 11-6 Specifications of Colour Test Pattern & Tone Generator

\'11: '() \\

'1,'1'

ii!!!

1"

!'"

(~:'

I

'

1. Doordarshan requires broadcast quality I sol.<;'l;1,r. pattern, _sync signal generator and tone .~est generator with test signals for analog TV transmitters. 2. It should work for PAL/625 line system. 3. The unit should have SNMP remote control facility to integrate automated service. 4. Technical parametersDescription Parametric values S.No. 230VAC±10%, 50Hz ± 2% Power supply 4.1 Output Connector BNC/XLR 4.2 video/audio 5°C to 45°C Operating Temperature 4.3 Output Impedance 750/120 4.4 video/audio Video Output Return loss >30dB 4.5 75% & 100% colour bar, linearity, flat Video Test signals 4.6 field, Multiburst, sweep (upto 6 MHz), pulse & bar, CCIRLine 17,18,330,331, video sweep for 250kHz to 6 GHz etc. -48dBU to + 12dBU (Resolution IdB) Audio Level 4.7 o to 20 kHz Audio Frequency 4.8

Page 52 of 88

DG: DD/TxD/lOkW 12011/EV I

Annexure 11-7 Specifications of T.V. Demodulator

Scope: TV Demodulators are required for measurements and monitoring the quality of transmission of the VHF/UH~ TV Transmitter. The detailed technical specifications are given blow:

1

GENERAL

..

1.1

It should be capable of operation in TV band III or IV, V(frequency range 174MHz to 230 MHz for VHF Transmitter and 470MHz to 862 MHz for UHF Transmitter). (CCIR PAL BIG) Channel change should be possible by DIP switch / Hex switch or Electronically by push buttons. It should have zero reference pulse facility to measure visual modulation depth. It should have switch selected sound trap 'ON' & 'OFF' facility. It should have switch selected envelope detection & synchronous detection. It should have squelch for noise suppression in case of absence of sound carrier failure.

1.2

1.3

1.4 1.5 1.6

2.0

2.1 2.2

INPUTS

!(

.; 1 · -"

t " ~:. ~

.

,

RF Input, impedance RF Input voltage

BNC female connector, 50 Ohms

:

.

Two switches are required for selection of input voltage ranges for RF input (a) 300 mV to 3.0 V (sync. Peak) (b) 0.5 dBm to 20.0 dBm (rms black

Page S3 of 88

2.2.1

RF Input voltage selection range with30 dB attenuation

DG: DD/TxD/l0kW

/2011/EV /

picture)

: l 4 i; ~i

:

1-', )111

!)

I

j

-\

"j

ii :\..1 j ; ,- ·

2.2.2

RF Input voltage selection range with 15 dB attenuation

(a) 80 mV to 800 mV (sync. Peak) (b) -10 dBm to +8 dBm (rms black picture)

., i;

, .'

.,

.....· 1!1

J,\1)

,ll'f"{)'.,'·:

{ !

\f

,

I

2.3 2.4

RF Input Return loss Gain control facility OUTPUTS Video Output Connectors & ~~nl impedance

-

~15 dB Manual or Automatic: is to be specified

3.0

3.1

i-j;~n

(a) Two BNC female outputs are .required (b) 75 Ohms

3.2 3.3 3.4

Video Output level Video Output Return loss Sound Output Connectors

1 Volt peak to peak (adjustable ±1.5 dB) ~ 20 dB (from 0 to 5.0 MHz) Two outputs with 3 Pin XLR female connectors

.

3.5

Sound Output level (at 30 KHz deviation and F mod=500 Hz) Sound Output Source impedance

+6 dBm ±0.5 dBm across 600 Ohms (adjustable ±3 dB) ::;30 Ohms

3.6

.

.

'

.

....

.'

.."

.'

4.0

4.1 4.1.1

Display Indications On Front Panel A Bar graph/numeric value display is required for indications. RF level indications (i) Low (ii) Normal (iii) High or the Numeric value.

4.1.2

Frequency deviation

o to 50 KHz

(linear) ..

Page 54 of 88

------------------------------------

DG:DD/TxD/10kW /2011/EV /

(After de-emphasis). 5.0 5.1 5.1.1 Transmission Characteristics Specifications for Video Channel Amplitude V s frequency response (a) ± 0.5 dB from 100 KHz to 4.43 MHz (with sound trap) (b) ± 0.5 dB from 100 KHz to 5.0 MHz (without sound trap) 5.1.2 Group delay Vs frequency characteristics a) ± 20 ns upto 4.43 MHz (with sound trap) b) ± 15 ns upto 5.0 MHz (without sound trap) 5.1.3 5.1.4 5.1.5 5.1.6 5.1.7 5.1.8 Differential gain Differential phase Tilt at 50Hz

I, ~:\" :

::;3% ::; ± 2 deg

r!,-,;)i.

1',- ",

,I

::;2% ::;2% , ::;2% ::::55dB

Luminance bar amplitude error Base line distortion Signal to noise ratio (At an input level ofl0 dBm)

6.0

Sound Channel

6.1 6.2

Inter carrier frequency Frequency response

5.5 MHz

± 1.0 dB wrt 50

j.lS

de-emphasis from 50 to

15 KHz

Page

55 of 88

DG:DD/TxD/l0kW

/2011/EV /

6.3

Harmonic distortion (At 50 KHz deviation and F mod=500 Hz)

·f >,

:S 1%

,.

. 1 I

I'" I

'II

6.4

Inter-carrier SIN ratio (At 50KHz deviation) Power Supply Dimensions/Weight Mounting Temperature for operation Relative humidity Maximum altitude

2::55dB

7.0 7.1 7.2 7.3 7.4 7.5

230 V ±10%,50 Hz, single phase To be specified by the bidder 19" Rack mountable 5 degree to 45 degree centigrade 90% NC at 40 deg C. 1500 M

The TV demodulator must be supplied with Mounting Arrangement Hardware (19" Rack Mount Kit) and all other standard Cables and other accessories.

Page 56 of 88

DG:DD/TxD/l0kW

/2011/EV /

Annexure 11-8 Specifications of Waveform Monitor

1. Scope:

1.1 Doordarshan Requires 2 Input (A&B) Analog waveform monitors for its TV Transmitters. These waveform monitors wi!l be as per the technical specifications of Doordarshan. The waveform monitors should be rugged, reliable and stable in operation. 1.2 The Waveform monitors should be quoted with product's detailed specifications datasheet pamphlets & operation Manual. It will be the responsibility of the bidder to ensure that the equipment is complete in all respects. All connectors and cable etc required for taking measurements should be supplied with the equipment 1.3 The set of waveform monitors should be 19" rack mountable. 2. TECHNICAL SPECIFICATIONS of Waveform Monitor 2.1 The waveform monitor must offer the performance monitoring and measurement capabilities of Analog composite video formats. 2.2 The instrument shall have dual Input monitoring facilities. 2.3 It shall provide facilities for monitoring of single H pulse and dual H pulse and monitoring of VITS signals. 2.4 The instrument should have the facility for monitoring of link A or B and combined input with a comprehensive set of displays 'and status '"reporttools. 2.5 The monitor should be capable to maintain correct timing between links A & B. 2.6 The Technical Specifications are given below: S.No 2.6.1 2.6.2 2.6.3 2.6.4 2.6.5 2.6.6 2.6.7 2.6.8 2.6.9 2.6.10 2.6.11 Parameter ' Format Input Dynamic Range f;"'-. Return Loss;

j I." -,

'

',->

i,·~.

. . i:.' ,\ ,

Cross Talk Loop through Isolation Max operating amplitude VertiCal': 'i measurement' Accuracy Gain In the multiples of 1, 2, 5 & 10. Frequency Response (0 to ±l% 5.5MHz) Sweep Time Accuracy ±0.5% Sweep Linearity 0.2% of time displayed on screen.

j ': ' :

Required Performance PAL ±6dB 35dB (Power OFF) 40dB (Power ON) >60dB >70dB 1.8V to 2.2V, DC + peak AC ±'1% 'all' gain :settings

~

\,.'

..

,.:,.,

'-'

..

Page 57 of 88

DG:DD/TxD/l0kW

/2011/EV /

3G cncra lR

C(

3.1 3.2 3.3

3.4

3.5

3.6

mrcmcn t s: Test Certificate of the instrument shall accompany each instrument on delivery The Equipment should have minimum 1 No. USB 2.0 Port. USB port should support USB flash drives/ connection to PC. The Software for PC Communications should be provided to work between a Windows PC and the waveform monitor via USB. It should be able to Transfer and save ·settings" waveforms, measurements and screen Images. Matching cables must be supplied with each equipment. The Waveform monitor must have BNC (female) input connectors. It should also have the facility loop through of video signal to monitor it on the video monitors. The Oscilloscope shall work on 230V±10%, 50 Hz ± Power Supply 2% AC supply. The power supply unit of the equipment shall be protected against overload short circuit and over-voltage etc. Environmental The equipment shall be capable of performing satisfactorily in the temperature range from 5°C to 45°C and humid conditions of 90% at 40°C NonCondensing.

4 ACCESSORIES All the essential accessories also to be included in the offer.

Page 58 of 88

DG:DD/TxD/10kW /2011/EV /

Annexure 11-9 Specifications ofVU Meter

3. Specification for VU meter It should be a stand alone unit, simple to operate and 19" rack mount. It must be a professional level monitoring in broadcast systems. The unit should have at least two Analog input (XLR type). The input range must be at least± 1OdB. Unit should have the facility of internal speakers.

4.

T ec h'mca I S,peci'fi fIons: Ica S. No. Description 2.1 Input Impedance

Parametric 600 ohm. 20dBu.

value

2.2 2.3 2.4 2.5 2.6

Maximum Input level Frequency of operation Accuracy Distortion

:

I. ' \ ~ I'

20Hz to 20KHz. ±ldB. <0.1, %. ~80dB.

SIN Ratio

·

··

"

.· .,. ··

~ f

1 ·.

;,

,

,

'- _

it,,",

.

,j"

I

Page 59 of 88

, , !'

I

",

DG:DD/TxD/10kW /2011/EV /

Annexure 11-10 Specifications.of RF Analyser:

1. SCOPE The RF Antnena Analyzer should be a precision portable instrument, suitable for making direct measurement and analysis on transmission lines of a "T.V. Transmitting antenna system" installed at a T.V. tower, in proximity of high radiation. It should capable to perform coverage mapping, Spectrum Analysis, Field Strength measurement RF power monitoring and provide GPS co-ordinates information. It should be a stand-alone integrated unit, rugged in consutruction, light weight, battery operated, portable and tropicalised to be used in open to air space on T.V. tower platforms.

11·~ 11

II

1.

I. II. 111.

Features and Measurements

required:

IV.

v.

VI. VII.

V111. IX.

VSWR and Return Loss Cable Loss Gain, Loss or isolation of antenna and devices such as filters, attenuators, amplifiers, etc. Distance-to-Fault(DTF) using frequency domain refectometery, with facility of omparison of electrical length of two cables. Field Strength Measurements RF power measurement Spectrum Analysis GPS co-ordinate Phase Measurement 2. Technical Specifications:

3.1 Antenna Testing: i. Sweep Frequency Range: VHF Band III and UHF Band IVN Range II. Freq. Resolution: ~ 100KHz for the full frequency range so that the level corresponding to each TV channel can be measured. 111. Display Points: selectable from 150 to 2000 points (selectable) for accurate measurement of Distance to Fault. 3.2 Measurement Range: i. VSWR: 1.00 to 6.00(Resolutioll 0.01) or better

Sse-?

$

Page 60 of 88

DG:DD/TxD/10kW /2011/EV /

11. 111.

IV.

v.

VI.

V11. V11l. IX.

x.

Xl.

X11.

Xlll.

XIV.

xv.

Return Loss: 0.00 to 50.00 dB (Resolution O.OldB) or better Cable Loss:O.OOto 20.00dB (Resolution O.OldB) or 'better Distance to Fault Parameters: Horizontal Range: 0 to 1500 meters or better This instrument should have the facility to display "Smith Chart" for transmission lines. The fault detection in a transmission line/cable with air and foam as dielectric should be possible for minimum 600 meters over full frequency range. Dynamic Range:80dB or better Directivity(correctedforvector errors): 42dB or better Test port available on analyser: N-type; 50 ohms R.F. immunity: The analyser should be immune to strong R.F. field atleast upto + 15dBm or better The built-in signal source should allow measurement of loss, gain or isolation of devices such as filters, cables, attenuators, amplifiers and antennas. Maximum input level: +20dBm, ±50V dc or better Phase measurement: Instrumentshould be able to make 1 port phase measurement and display S Ii parameter on the instrument display.

3.3 Field Strength Measurement: 1. The unit should have built-in Field Strength measurement capability for television signals anq. shall. be. supplied with all the required accessories such as standard calibrated omni-directional dipole/log periodic antenna to cover both VHF and UHF frequency band, suitable tripod, pole, test port cable etc. Certificate of calibration for the Anfenna should be supplied along with the goods. Correction factor data should also be provided. 11. Frequency range: VHF Band III and UHF Band IV/V Range Frequency resolution: better than 10Hz 111. IV. High stability oscillator: frequency stability ±1 ppm or better V. Level resolution 1:,0.1dB VI. EMF voltage measurement: should be possible to measure the EMF Volage from 5dBIl V to + 120dBIl V or better

V11. V111. IX.

X.

Field Strength Measurement: should be possible to measure the field strength from -5 dBIlV/m to +120dBIlV/m or better. Detection systems: Max Peak, RMS Average/Average value. Detection Scale Units: dBIlV/m, dBm/m Antenna type: Half wave standard dipole or log Periodic or any other suitable standard antenna with tripod pole to have 10M height of receiving antenna and connecting cable of minimum 12 m should be offered.

l'j'

Xl.

Received Signal strength mapping: Instrument should be able to perform coverage mapping using software supplied with the unit.

Page 61 of 88

DG :DD/TxD/IOkW /2011/EV /

I':

;

tl.i

.

I'.

l- .··. l

i,

,',

I

.t.,t

XII.

It should be possible to make field/Signal strength measurement in the field stamped with GPS Coordinates and overlayed over the map captured in the unit from Google Ma using software supplied with the unit. It should be possible to save the mapped results and transfer to PC or Laptop using USB drive or LAN.

3.4 Spectrum Analysis and Power Measurement: 3.4.1 Frequency:

1. 11. 111.

IV. V.

VI. Vll. Vll1.

IX.

X.

Xl.

Frequency Range: 100KHz to 4GHz Frequency Tuning Resolution: 1Hz Frequency Reference: Aging:S ±lppm or better. Accuracy:S ± 2ppm or better. Frequency Span: 10Hz to 4GHz in 1-2-5 steps plus zero span mode. Resoultion Bandwidth: 10Hz to 3MHz in 1-3 steps, Accuracy ±5% Video Bandwidth: 1Hz t03MHz in 1-'3steps~'Acctirac:Y'±5%"'" , Selectivity(3dB): 10Hz (min) Level Resolution: O.ldB SSB Phase Noise at IGHz: better than :S-100dBc at 10KHz offset Spurious Response: :S-90dBm for frequencies ~ 10MHz. Sweep time ( full span): should be adjustable by the instrument automatically according to the RBW value selected and optimized according to the signal applied for measurement.

tl '

3.4.2 Amplitude

1.

11.

111.

IV.

v.

VI.

VII.

Vlll.

IX.

Measurement Range: -150dBm to +25dBm Protection against max. input level: The instrument should have internal protection against the maximum input level upto +35dBm(peak, continuous); ± 50V de. Average Noise Level: :::-150dBm (Frequency: >10MHz; RBW :10Hz, OdB attenuation. ) Total Level Accuracy: ±1.25dB, ±ldB(typical) (over full frequency range) Display Scale units: dBm,dBV,dBmV,dBflV,flV,mV,nW,flW,mW,and W. Display Range: 1 to 10dB/division, in 1dB steps, 10division display. Detection System: RMS average, Positive Peak, Negative Peak, Sample Mode, Quasi Peak Input Attenuator Range: 0 to +50dB. Channel Power Measurement: -120dBm to +25dBm at the coupled ports of the transmitter.

3.5 GPS Receiver The instrument should have built-in GPS receiver to provide the Longitude, Latitude in six figure co-ordinates and Altitude in meters. It should be possible to save the GPS information with trace in the internal memory. Suitable GPS antenna with min 5m cable should be offered.

jfl

Page 62 of 88

DG:DD/TxD/IOkW /2011/EV /

4 General Features and Specifications i. Weight: To be specified by the bidder 11. Temperature Range (for operation): 0 deg C to 45 deg C 111. Relative humidity (for operation) 90% NC at 40 deg C. IV. AMSL: 1500 M v. Power Supply: Operatable on 230V ± 10% AC, 50Hz mains and 12Volt dc/chargeable battery, with back up of at least 3 hours, should also have facility of charging from vehicle battery. vi. Display: The analyzer should have coloured LCD/TFT screen to display the measured traces. vii. The instrument should have multi-marker (min:6) displayed on the screen to see the return loss and VSWR at different frequencies simultaneously. viii. The segment limit lines feature should be available for pass-fail tests. ix. The instrument should have the spectral emission mask feature to confirm the transmissions within the approved limits. x. Instrument should have limit line feature to create mask for confirming measurements within threshold limits. If the applied signal exceeds the threshold limits, provision should be there to automatically save the event into the internal memory of the unit. It should be possible to recall the saved results from memory to analyse the events of violation oftheshold limits. xi. Instrument should be s'upplied with USB and LAN interface and the required software for easy transfer of saved data into PC/Laptop and vice-versa

5 Plotter/printer: a) The analyser should have RJ45 interface for printing on Deskjet/laser printers and PCs. b) Internal memory 'and Storage capacity: Minimum 2000 traces and 2000 sets of instrument configurations. 6 Accessories and Options: a) All accessories/options required for measurement ofVSWR, cable loss, return loss and Distance to Fault ofT.V~transmitting antenna and RF feeder cables, spectrum analysis, GPS and field strength measurement are required to be quoted with the

M~~~ . .,.

b) Standard acc'essories to be supplied with the unit should be clearly specified in the offer. c) Carrying case shall be offered for easy handling in the field and safer transportation and shall form part of the offer.

"j

Page 63 of 88

~' !,

i,;'

·

f

1 \

.! . I I ~~1

(

'1!

:

1,

i

I

1

, , ' \',

· - 1 f ~ ,-

I,

· . ·

DG:DD/TxD/10kW /2011/EV /

Annexure 11-11 Specifications for Audio Analyser

SCOPE: The Audio Analyzer should be a precision instrument, suitable for making direct Audio measurements of a "T.V. Transmitter system". It should be capable to monitor all the Audio parameters of a Analog TV Transmitter system. 2. Features and Measurements required: 2.1 Analog Audio measurement functions: Instrument must have the facility to measure the following Analog audio parameters of an Analog T¥ Transmitter-, \ i (i) Lcvel (ii) Cross talk (iii) Frequency (iv) Total Harmonic distortion (v) Noise (vi) Wow and Flutter (vii) Drift (viii) Intcr modulation Distortion (ix) Narrow band selective level (x) Spcctral FFT analysis 1.

".:'

;

l

i ,

I.

"

i ;

i

!

'-

I!,

i

>1

i

'

3.0

Technical Specifications:SL. NO. Parameters Standard General Data Operating Temperature Range Humidity Power Supply Audio Inputs/Outputs Connectors Frequency Range Values PAL B/G colour standard 5 to 45°C 90% (Non conditioning) at 40°C 230V ± 10%

.

.

1. 2.0 2.1 2.2 2.3 3.0

3.1 3.2

BNC, two channels simultaneously operating. 10 Hz to 80 KHz.

Page 64 of 88

DG :DD/TxD/I0kW

/2011/EV /

3.3

3.4 3.5

Frequency response from 20 Hz to 20 KHz. (Referenced to 1 KHz) Common Mode Rejection at 1 KHz Harmonic Distortion Fundamental Range Maximum Input Voltage

±0.05dB

::::75 dB 20 Hz to 20 KHz

3.6

33 Volt RMS

'1

'

Page 65 of 88

,

:,'

"

DG:DD/TxD/lOkW /2011/EV /

Annexure 11-12

A. SPECIFICATIONS OF RF STEP ATTENUATOR . S. No. Parameters Values .. Frequency Range DC-IGHz 1. (0-10 o dB)

.

.

.

2. 3. 4. 5. 6. 7. 8.

dB Value Connectors Impedance VSWR Accuracy Insertion Loss RF input Power Avg Peak Temperature

0-100 dB in 1dBIl OdB steps (F ine/Coarse steps) BNC SO Ohms

'. ; l

!

1.2:1 (DC-SOOMHz) 1.4: 1 (SOOMIiz.-: I,GHz) ± 0.2 dB (DC-SOOMHz) ± 0.3 dB (SOOMHz-IGHz)

0.5dB upto 1 GHz 2 Watt 1000W 0° C to SO° C

9.

B. SPECIFICATIONS S. No. Parameters

1.

OF RF FIXED ATTENUATOR Values

DC-IGHz 3dB, 6dB, 12dB (each one independently) N type SO Ohms 1.2: 1 (DC-SOOMHz) 1.4: 1 (SOOMHz-IGHz) ± 0.2 dB (DC-500MHz) ± 0.3 dB (SOOMHz-IGHz) O.SdB upto 1 GHz 1 Watt Rugged unibody 0° C to 50° C

3 dB, 6 dB, 12 dB (N type)

2. 3. 4. 5. 6.

Frequency dB Value Connectors Impedance VSWR Accuracy

Range

7.

8. 9.

10.

Insertion Loss RF Input Power Construction Temperature

Page 66 of 88

DG:DD/TxD/lOkW /2011/EV /

Annexure 11-13 Specifications of Computer With 600 VAUPSand Laserjet Printer:

1.0 Scope: Doordarshan (DD) intends to procure Computer system based on latest technology. The computers should be rugged, reliable, and stable in operation under very cold to hot, humid and dusty environmental conditions. Detailed specifications of the Computers are given in this document. The Computers wi,ll be supplied along with Uninterrupted Power Supply (UPS) and Laser printer. The computer manufacturer / bidder must have his local office / representative in India. 1. 1 Computer Configuration Specification S.N o. Description Intel Core is a. CPU Intel OEM Motherboard b. Chipset Integrated Graphics, 2 PCI, 1 PCI Express x 1 and c. Bus Architecture 1 PCI Express x 16 2 GB DDR3 RAM with 4GB Expandability Memory d. 500 GB 7200 rpm Serial AT A HDD Hard Disk Drive e. 17" LED Digital Colour Monitor f. Monitor 104 keys g. Keyboard Optical " h. Mouse 4 Nos. (2 Nos. 5.25 inches for Optical Media 1. Bays Drives and 2 Nos. 3.5 inches for Hard Disk , "'Drives)'

! ,: '. ; ': .

J.

k. 1.

m.

n. o.

6 USB Ports (with at least 2 in front), 1 Serial audio ports for microphone and headphone III front Cabinet Mini tower DVD ROMUrfve} .. 16X()r better DVD ROM Drive ··· Networking 10/100/1000 on board integrated Network Port facility ,., with remote booting' .facility remote system installation, remote wake up Modem Dial up 56.6 kbps. Operating System Windows Seven professional preloaded with Media and Documentation and Certificate of ; .. > ·· ,~ ." Authenticity': >'1 ,::" ~ ' ': Ports

,.\1:

p. q.

OS Certifications Power Management

Win Logo Seven professional OS Certification Screen Blanking, ,Hard, Disk and System Idle Mode in Power On, Set up Password, Power supply SMPS Surge protected Norton, McAfee, or equivalent Antivirus (Latest

Page 67 of 88

r.

Preloaded

'1'

"

DG: DD/TxD/lOkW /2011/EV /

___

I Software

I Version) with '365-days'l:-icense1andopen office'

Laser Printer S. No. Description a

b

i

Specification Black and White 600 x 600 dpi

lillli.... .'" ,jl'

Output Type Resolution Page per Minute(PPM) Papcr size Interface L~~~~ss~rycables & Utility Software t() be supplied.

.. '/

c

d

i

16A4 USB 2.0

e f

3.0 600 VA offline UPS S.N Description

0

Specification

-

a b c d e f g h

1

Capacity Output waveform Voltage on Mains Frequency(Input) Backup time Frequency( on Battery) Transfer Time Over Load Indication Charger Short circuit protection Protection Battery

J

k 1

600 VA Stepped approximation to a Sinewave 100 - 265VAC 47 - 53Hz 30 minutes 50Hz±1% <20 milli seconds 100% for 60 seconds, Indications Via LED & Audible alarm with 3 times restart Constant Power, 2 step charging Input voltage range 100 - 270V Multiple short circuit protection provided Overload, short circuit, .low battery Over charge, Main slow & High input voltage Sealed Maintenance free Cold Start, No-load AutoShutdown

Page 68 of 88

DG:DD/TxD/lOkW /2011/EV /

Annexure 11-14 Specifications

of Professional IRD for C-BandjKu-Band:

1.1. General: 1.1.1. The IRD should have a front panel display and one should be able to enter or edit all the parameters for a perfect reception of the signals. 1.1.2. There should be provision for observing the BER (Pre & Post correction) for DVB-S and CIN or PER (for DVll:S2)ofthe~ignaland signalleveLin the front panel. 1.1.3. IRD should be able to de scramble BISS mode 1 and BISS-E signals. 1.1.4. IRD should have at least 10 memory setups to store channels. 1.1.5. IRD should have CI slot so that by inserting the CAM module signals can be descrambled. 1.1.6. If IRD's output port are configurable then there should be minimum 3 ports, so that at any given point of time, at least one Analog, one SDI and one DVB-ASI output will be available by configuration.

1.2. RF Parameters: S. No. a. b. c. d. e. f. g. h.

1.

Parameter Input Frequency Range N6.ofInputs ,', ..

'I

Specification 950 - 1750 MHz '", f TNo. ' 125 kHz, maximum C- & Ku-Band, selectable 75 Ohms F-Type female -30,to -65 dBm per carrier >30 dB 7 dB, minimum .. 20 dB, maximum ± 5 MHz DVB-S QPSK, DVB-S2 8PSK demodulation 1.0 to 44.5 M symbol/Sec ( DVB-S) 1.5 to 30 M symbols/sec, minimum (DVB-S2)

'

','

"

:'

"

i.

k. 1.

m

Tuning Step Size Satellite Frequency Band Input Impedance Input Connector Input Power Range Image Rejection Input Return Loss, Noise Figure AFC Tuning Range De- Modulation Method Variable Symbol Rates

< ·· "

,

n. Convolution Inner FEC Rates selectable

,

,

R= Y2, 2/3, %,5/6, 7/8( DVB-S option) QPSK R= 2/5, Y2, 3/5, 2/3, %, 4/5,5/6,8/9,9110 (DVB-S2)

Page 69 of 88

"I

,

..~

'.?J

--!:

i", '! "....·

,j , 1~ "

t

'

__

.,\11

.·. 1 .·

;!1_

DG:DD/TxD/l0kW

/2011/EV /

o. IF Filter Bandwidth Note: ASI to SDI decompression Converter. 1.3 Audio and Video Decompression S. No. Parameter Video Resolution (all resolutions shall be capable of I, P & B frame decoding) Video Decompression Type Television Standard Audio Decompression Type

Automatic Selection (dependent on Symbol Rate) should take place directly, i.e., not through Analog to Digital

Parameters: Specification 720 x 576, 704 x 576, 544 x 576, 480 x -- 576, 352x576 (other standard resolutions should be selectable) [email protected] . PAL-B MPEG-l Layer-II audio (Stereol Musicam, i.e. Single Mono, Dual Mono, Stereo, and Joint Stereo) AC-3 Pass through

1.4 Transport

Stream O/P:

MPEG-2 DVB-ASI on BNC

1.5 Video Output Specifications:

1.5.1

Analog Video Output Specifications S. No. (a) (b)

1

Parameter Connector Type Quantity Level

Specification BNC (75 Ohms) 1 No. of analog composite PAL-B CCIR Standa.rd . 1.6V p-p ± 5%

Page 70 of 88

DG:DD/TxD/l0kW

/2011/EV /

1.5.2

Digital Video Output Specifications S. No. (a) (b) Parameter Connector Type Quantity Specification BNC (75 Ohms) 1 No. of DIGITAL output compliant to ITU-R BT.656 Standard 800m V p-pfor SDI SMPTE 272-1994,270 Mb/s (10 bit)

I (d) 1.5.3

Level' Serial Interface

.

Video Performance Specifications S. No. (a) (b) I (d) (e) (f) (g) (h) Parameter Frequency Response Chroma-Lurria Delay Field Time Distortion Line Time Distortion Short Time distortion Differential Gain Differential Phase Signal to Noise Ratio

I .~ i

Specification Within 2 dB down at 5 MHz , '±30 us, maximum <2% < 1% <2% <4% < 2° >55 dB (luminance weighted)

\ :.-

.

i-

;..

'"'

··

\,',;':'

1.5.4

VBI Signal Reinsertion Specifications: S. No. Parameter VBI Formats Supported Range of VB I lines Specification WST VITC Field 1 lines 7 to 22 (PAL) and corresponding lines of Field 2 Within ± 1 frame VBI data shall be reinserted on the original line number

..

Synchronisation with Video Preservation of line ' numbering 1.6 Audio Output

1.5.2 Analog Audio .' . ., " 1.5.2.1 Each analog audio output'shalfbe presented as a ste~ebpair. 1.5.2.2 In the event of "Mono" ~ransmi~s~ons, the same input c~annel will be output to both left and right connectors. '

~

----'

Page 71 of 88

·~

PG:DD/TxD/lOkW

/2011/EV /

1.5.2.3 In other modes ("Stereo", "Joint Stereo" and "Dual Mono"), the two input channels will be output as left and right. ·.: : 1.5.2.4 Means shall be provided to combine the left and right channels on the IRD output to produce a mono output from stereo transmissions to accommodate those sites not equipped for stereo transmission. 1.5.3 Analog Audio Output Specifications S. No. (a) (b) I Parameter Output Impedance Number of Outputs Connector Type

..

Specification

(, I, 6000 (balanced)"

"'I! ('

flrH~I, II/

4, configurable as Stereo, Joint Stereo, Single mono, Dual mono. XLR Male Socket or with suitable XLR Adopter (i.e., no terminal block)

1.5.4

Digital Audio Output Specifications

)i

S. No. (a) (b) I (d)

Parameter Output level Output Format Load Impedance Connector Type

Specification 2-7 Volts nominal· AES/EBU 110 Ohms XLR Male Socket or with suitable XLR Adopter (i.e., no terminal block) 2, Stereo Channels at 256 Kbps and sampling rate of 48 KHz Specification + 18 dBm into 6000 balanced S/W Selectable to be provided or any preset value between + I8dBu to +25 dBu .. " 48 KHz 40 Hz to 20 kHz ± 2 dB <0.3 % at 1 kHz 80 dB (ITU-R1Arm weighting) 60 dB, full scale (20 Hz to 20 kHz) 55 dB (min) at 0 dBm

Page 72 of 88

(e) 1.5.5

Number of Outputs Specifications

Audio Performance S. No. (a) (b)

Parameter Peak Output Level Clipping Level

I (d) (e)

(f)

(g) (h)

Sampling Rates Frequency Response THD Dynamic range Crosstalk at 1 kHz Signal to noise ratio

DG:DD/TxD/10kW /2011/EV /

1.5.6

LNB Power Supply &-Control S.No. (a) (b) I (d) Parameter LNB Voltage Power Consumption Over Current protection LNB Power Supply & Control

'". ,

Specification + 13 V (Vertical)/ 18 V (Horz) polarizations switching or 19 V fixed. 400 mA. -(Max.) Fold back current limiting. Receive Polarization Control by electrical Command Via LNB-IF feeder (High & Low band switching Pulse for Ku Band operation).

1.5.7

Size - Mount:

19" rack mountable.

,Y

~

-

~,_'<' \ :,

I

',;

\ Iii

t."~

·

Page 73 of 88

DG:DD/TxD/10kW /2011/EV /

Annexure 11-15

Specifications of 60 KVA 3 Phase Input 3 Phase Output UPS System

Alongwith Isolation Transformer

GENERAL:

for TV Transmitters

Doordarshan requires Uninterrupted Power Supply System (UPS System) for backup Power Supply for its YHF /UHF High Power TV Transmitters. The UPS should be reliable and stable in operation under Indian tropical conditions. This Specification describes a 60 KVA three-phase, True on-line double conversion continuous operation (defined as VFI in the IEC62040-3 UPS Specifications), solid-state Uninterruptible Power Supply. The UPS system shall be capable of running with 15 minutes back up time at full rated capacity. All connectors & cables etc. required for UPS System & its installation should be supplied with the 'equipment: The ,UPS System-quoted must conform to the latest international standards of safety and EMC. The conformance to such standards (indicating standard's name & number) must be stated in compliance statement. The UPS and battery manufacturer must be ISO 9001-2008 certified for manufacturing of UPS and battery (respectively). A copy of the valid ISO 9001-2008 certificate should be enclosed with the offer. The installation of batteries should be carried out within 15 days after receipt at site.

2. TECHNICAL SPECIFICATIONS OF UPS SYSTEM: 2.1 The UPS shall produce high quality sinusoidal output. The UPS shall be designed to operate as true on-line, double conversion type UPS strictly as per the definition of IEC 62040-3 as follows: 2.1.1 Normal Operation: The critical AC load should be continuously supplied by the UPS inverter. The rectifier & charger should take power from the AC input source, covert it into suitable DC and supply to the inverter as well as charge the Batteries on Automatic Floafcum Boost Mode." . '.. 2.1.2 Upon Mains Failure: Upon failure of AC input power, the critical AC load should continue to be supplied by the inverter, which should obtain power from the battery. There shall be no interruption in power to the critical load upon failure or restoration of the AC input source. 2.1.3 Upon Mains Restoration: Upon restoration of AC input power, the Rectifier/Charger should automatically restart walk-in and gradually take-over the supply to inverter and charging to the battery. . 2.1.4 Static Bypass: Each UPS Module should have in-built 100% rated static Bypass Line. 2.3 Static Transfer Switch:

Page 74 of 88

DG:DD/TxD/10kW /2011/EV /

Static Transfer Switch and bypass circuit shall be provided as an integral part of the UPS. The static switch shall be naturally commutated high-speed static (SCR Type) device rated to conduct upto 135% of full load current, continuously. The Overload withstanding capability of Static Bypass Path should be 1000% for 100 millisecond, 135% - 170% for 10 minutes. Maintenance Bypass Isolator: 2.4.1 General: A manually operated maintenance bypass isolator shall be incorporated into the each UPS cabinet to directly connect the critical load to the input AC power source, bypassing the rectifier/charger, inverter, and static transfer switch. 2.4.2 Maintenance Capability: With the critical load powered from the maintenance bypass circuit, it shall be possible to check out the operation of the rectifier/charger, inverter, battery, and static transfer switch. Technical Specifications: 2.5.1 System continuous rating 60 KVA, 54 KW at 0.9 power factor. 2.5.2 Battery Capacity: The UPS system must be capable of providing supply to the UPS Inverter/s on 60 KVA/48 KW load for, minimum 15 minutes of battery back-up time. The Battery Bank shall be MF-VRLA type (Make GNB/ Amara Raja/ HBL Nife) consisting of2 V cells installed in proper standard cabinets with proper connections and in factory charged condition. The batt~ry calculation is as follows: BATTERY SIZING CALCULATION GUIDELINE (FOR VRLA BATTERIES) Type of Battery : Maintenance Free Valve Regulated Year Design Life (Amara Raja/HBL Nife/GNB Make/Exide). Nominal DC Bus Voltage : X Volt DC Nominal Cell Voltage : 2 V per cell Thus, No. of Cells (N) : (X/2) End Cell Voltage (V) : 1.75Volts

. ·. ,_ ,. .. . '. ' (: \ i

Lead Acid With 20

I

',I. 1\

~ ".

J ·.·.·. 1 .; .. {

.i. ···.·

!1

t

ir

t': . ii',

\

tit

i·..! i·(

I)

'1"._ ,\

Load Duty Cycle (L) : 54 kW Continuous Inverter Efficiency E : (93%) Back up Time : 15 Minutes Maximum Current for the above Load (I dc) = Lxi OOO/(VxNxE) Amps. DC The Other Factors to be Considered: 1) Temperature Correct,ion Factor, (T). , 2) Capacity Factor (K) V to be s ecified b the OEM of batter .

'. ,'t, I,

. 1.0731 (400C) K factor at the end cell voltage of 1.75

Page 75 of 88

.~

---

DG:DD/TxD/l0kW

/2011/EV /

'')\1:

'f""

I ill)!

:

'"iil1lll11

;11

11)0°" I" i.:1

'11

Considering the above Factors the required Battery Capacity

= =

I dc x K x T AH must be provided

Calculation of the Battery Capacity, b the OEM.

as per the above formula,

2.5.3 Rectifier Input: 415 Volts, three-phase, 4-wire-plus-ground i J i!' <It rdll'd Bypass input: 415 Volts, three-phase, 4-wire-plus-ground. Output: 415 Volts, three phase, 4-wire-plus-ground. 2.5.4 Input Voltage range: 320 V to 460 V, (415 V nominal) for 100% load 2.5.5 Input Frequency: 50 Hz 2.5.6 Frequency Tolerance: 45 Hz-55 Hz 2.5.7 Power Walk in: 5 - 30 seconds (User programmable) 2.5.8. Input Power Factor 2:. .98 for all loads

! "1 ~ 1 1

j., \

In order to achieve this, the Rectifier must be IGBT based; Power Factor Corrected and DSP Controlled. ".... - - .-2.5.9 Input Current Harmonic Distortion: .:S 4% THD maximum at 100% load and ~3% THD at 75% load at nominal input voltage. 2.5.10 Output Voltage regulation: +/- 1% steady state for astatic 100% balanced load. +/- 2% steady state for a static 100% unbalanced load. +/- 5% for a 0 to 100% load step. 2.5.11 Output Frequency: 50 Hz +/- 0.1 Hz free running (battery/mains operation). 2.5.12 Output Power Factor Range: 0.9 leading to 0.9 lagging at rated KVA. 2.5.13 Output Harmonic Distortion: <2% THO maximum for a 100% linear load. <5% THO maximum for a 100% non-linear load. 2.5.14 Crest Factor: 3: 1 or better 2.5.15 Voltage Transient Response: +/- 3% for a 50% load step. +/- 5% for a 100% load step. 2.5.16 Voltage Transient Recovery Time: 20 milli-seconds. 2.5.17 Phase Displacement: 120 degrees +/- 1 degree for balanced load. 120 degrees +/- 1 degree for 50% unbalanced load. 120 degrees +/- 2 degree for 100% unbalanced load.

Page 76 of 88

DG:DD/TxD/l0kW

/2011/EV /

The system should be capable of supplying energy to load from commercial mains without any break, in case of phase reversal at the input. It should also generate aural and visual alarm in such a case. 2.5.18 Overload Capability: 110 % for 60 Mins. 125 % for 10 Mins. 150 % for 1 Mins. 1000% for 100 milliseconds & 135-170% for 10 Mins in bypass operation. 2.5.19 Short Circuit Withstand: The UPS must withstand a bolted fault short circuit on the output without damage to the UPS module. 2.5.20 Inverter efficiency: ~93% at 100% Non linear load, at nominal voltage with batteries fully charged. 2.5.21 Acoustical Noise: .:S 67 dB (A) of noise, typical, measured at 1 meter from the equipment surface. 2.5.22 Transient Voltage Surge Suppressor (TVSS) should be provided at the input & output of the UPS System. 2.5.23 Please specify UPS Cubical and Battery Rack dimensions LXBXH in meters. Floor layout plan with dimensions may be given. Environmental Condition: The UPS shall be able to withstand the following environmental conditions without damage or degradation of operating characteristics: 2.6.1 2.6.2 2.6.3 2.6.4 above Operating Ambient Storage/Transport Relative Humidity: Altitude Operating: Mean Sea Level. Temperature for UPS: O°Cto 45°C Ambient Temperature for UPS: -lOoC to +50°C <90% at 40°C ;TheUPS should be able to deliver the rated output up to 1500 meters

it':

I

2.6.5 Input Current Walk-In: The rectifier/charger shall contain a timed walk-in circuit that causes the unit to gradually assume the load over a 5 to 30 second (User Programmable) time interval after input voltage is applied. 2.6.6 DC Filter: The rectifier/charger shall have an output filter to minimize ripple voltage into the battery. The Ripple voltage should be less than 0.5%. The Ripple Current should be ::; 5% of battery AH capacity.

-/-

Page 77 of 88

'ji;

I

DG:DD/TxD/I0kW

/2011/EV /

Battery Recharge: In addition to supplying power for the inverter load, the rectifier/charger shall be capable of providing battery charging current to recharge the battery properly (up to 10% of battery AH capacity). Total Battery Management and monitoring should be available in the System. In addition to the above manual charging current control may also be provided:-2.6.8 Output Frequency The output frequency of the inverter shall be controlled by an oscillator. The Oscillator shall hold the inverter output frequency to ± 0.1 Hz for steady and transient conditions .

." I 1 ,

(1

I

<,'

I

,

1 :- ( \ ~ ,.;

2.6.9 Low Battery Voltage Protection: To prevent total discharge or damage to the battery, the UPS must transfer to standby operation _when the battery,voltage.reaches.a,minimum voltage level (programmable ). 2.6.10 Battery disconnect: An external MCCB is to be provided for protection and isolation of the battery bank from the rest of the system. 2.6.11 RF Shielding: The UPS must have RF (Radio Frequency) radiation shielding since it will be installed in strong RF field environment of 10 KW power. Any failure of electronics due to RF pickup must be taken care of by the manufacturer.-

3.0 3.1.

DISPLA Y AND CONTROLS:

Monitoring and Controls: The UPS shall be provided with a status display and control section designed for convenient and reliable user operation. A system power flow diagram, a percentage load and battery time remaining display shall be provided as part of the monitoring and controls sections which depict a single line diagram of the UPS. The monitoring functions such as metering, and alarms shall be displayed on a Graphic florescent backlit LCD. Language features of the monitoring system shall be in English. Minimum 250 Pieces Historic Event Record should be there. 3.2 Metering The following parameters shall be displayed: ... a) Input Voltage & Currents, Frequency, Power Factor b) Bypass: Phase Voltage, Line-Line Voltages, Frequency c) UPS Output: Phase Voltages, Currents, Line-Line Voltages, Power Factor, Frequency d) Local Load: Load of Each Phase Active Power (KW), Apparent Power (KV A) of each Phase, Load Crest Factor

_ Page 78 of 88

41/

DG:DD/TxD/10kW /2011/EV /

e)

Battery: Battery Bus voltage, Battery Charge & Discharg~ current, Forecasted Battery Back-up Time, Battery Temperature Battery Capacity (AH) f) Parallel Load (for Parallel Operation System): Apparent Power (KVA) of Each Phase, Active Power (KW) of Each Phase

3.3.

Warning, Protection

and Alarm Messages:

Input/Mains: Charger Fault, Input Fuse Fail, Control Power 1 Fail, Mains Phase Reversed, Mains Voltage Abnormal, Mains Under-Voltage, Main Frequency Abnormal generator connected, Input Disconnect Open/closed Rectifier/Input Inductor/DC Bus/Booster/Balancer: Input Inductor over Temperature, rectifier Fault, rectifier over-current, Soft Start Full, Rectifier Comm. Fail, Rectifier in setting, Rectifier Over Temperature, DC Bus Abnormal, DC Bus OverVoltage, Balancer Fault, Balancer Over-Current, Balancer Over-Temperature c) Battery: Battery Over-Temperature, Battery Fault, Battery replaced, Battery Low pre-warning, Battery end of Discharge, Battery contactor Fail, Converter Over-Current, Battery Capacity Testing, Battery Maintenance Testing, Battery .Fus~ Fail, Battery Contactor Open/Closed, Battery Reverse, No Battery, Battery Float Charging, Battery Boost Charging. d) Inverter: Inverter Over-Current, Inverter Asynchronous, Inverter Fault, Inverter inductor overtemperature, Inverter Over-Temperature, Inverter communication Fail, Inverter STS Fail, Inverter DC Offset, Inverter in Setting. e) Bypass: Bypass STS Fail, Bypass unable to 'trace, 'Bypass Abnonnal, Maintenance Disconnect Open/Closed, Bypass disconnect open/closed, Bypass Abnormal Shutdown, Bypass Phase Reversed, Bypass overcurrent f) Paralleling: Parallel Board Fault, System Transfer, Parallel Communication Fail, Parallel Connect Fault g) Module's Common: Normal Mode, Battery Mode, Bypass Mode, Ambient Over-Temperature, Fan Fault, System Overload, Manual Turn-ON/OFF, Unit overload time-out, Operation Invalid, Output Fuse Fail, Control Power 2 Fail, Unit overload, Joint Mode, UPS Shutdown, Output disabled, Transfer confirm/cancel, Unit OFF confirm, System OFF' confirm, .Fault Reset, Alarm Silence, Output Disconnect Open/Closed, Turn-ON Fail, Output Over-Voltage (reserved), Alarm resent, Load impact Transfer, Transfer Time-Out, Load Sharing Fault, Parallel ID Error, EPO, Setting Save Error, Mains neutral Lost, UPS System testing, protocol version Clash.

"

-

'~

-ij

..

'"''''

.

----

Page 79 of 88

DG:DD/TxD/10kW /2011/EV /

1-;' 1

f ;

I \ I)

3.4

Power Status Diagram: 1. A mimic panel shall be provided to depict a single line diagram of the UPS. Illuminating lights shall be integrated within the single line diagram to illustrate the status of the UPS. The three LEDs shall indicate the following status. 2. Bypass voltage OK > 3. Load on bypass 4. Load on inverter

,it ."

Controls: The following controls have to be accomplished with the display unit: 1. Silence an audible alarm. 2. Set the alphanumeric display language to English or the alternate language. 3. Display or program the time and date. 4. Enable or disable the automatic restart feature. 5. Transfer to or from static bypass operation. 6. Transfer to or from forced battery operation. 7. Program the unit for economy operation. 8. Program the battery charger. 9. Calculate battery back-up time. 10. Test battery condition on demand. 11. Program the unit to periodically test battery condition. 12. Program voltage and frequency windows. 13. Calibrate metered parameters. 14. Enable or disable adaptive slew rate. Set maximum slew rate. 15. Adjust set points for different alarms. 16. Program the remote shutdown contact (enable/disable remote shutdown, polarity display). 17. Set the delay of the common fault contact. 18.Program the unit for soft start for use with a generator. 3.5 Communication Features: 1. RS-232 / RS485 interface ports as standard feature 2. SNMP/HTTP Network Interface. 3. MODEM Card. 3.6 Remote UPS Monitoring Kits: Remote UPS monitoring must be possible via either RS-232 or contact closure of the UPS.

Page 80 of 88

DG :DD/TxD/IOkW /2011/EV /

SNMP adapter:

.

A Web-Enabled SNMP adapter.for,one or more network management systems (NMS) to monitor and manage the UPS in TCP/IP network environments should be available. The management information base (MIB) must be provided. The SNMP interface adapter has to be connected to the UPS via the RS232 serial port.

3.8

UPS On And Off Switches:

Momentary UPS on and off Switches must be provided in a user accessible area. Upon activation of the Switches, the UPS must_ automatically connect the UPS. output to the critical load. Upon deactivation of the Switches, the UPS must remove power from the critical load.

3.9

Integral Maintenance

Bypass:

The Integral maintenance bypass has to supply the load from the bypass source while the UPS is isolated for maintenance. UPS input, output, static bypass and Maintenance Bypass Switch must be housed in the same cabinet. Each switch must be monitored and controlled by the UPS.

3.10

Battery charger temperature

compensation:

charger temperature compensator has to monitor the

For units with external batteries, the battery temperature in one battery cabinet.

4.

ISOLATION

TRANSFORMER

The isolation transformer should be three phase, naturally cooled type, housed in one steel cubical provided with unidirectional cast iron wheels at bottom and lifting hooks at the top. The cubical enclosing the isolation transformer should have doors on front and rear side, bolted side covers and removable top cover. S. No. a.

b.

c. d. e.

hase to neutral)

f. <4%

h. More than 500 Mega Ohms at 500Y

Page 81 of 88

------------------------------------

.. ----------

.. -

DG:DD/TxD/10kW /2011/EV /

1.

J. k. 1. m.

Terminals Cable entry Efficiency Insulation Class ENVIRONMENTAL CONDITION: I.Operating Ambient Temperature 2.Storage/Transport Temperature 3.Relative Humidity

Studs on fiber glass plate at rear Bottom .~97% Class F SaC to 4SoC OOCto SOOC

. _ .. ...

--

--

-. -.

~-

upto 90% at 40°C (Non-Condensing)

Page 82 of 88

DG:DD/TxD/10kW /2011/EV /

Annexure 11-16 Specifications of 75 KVAAVR:

INTRODUCTION: 1. Servo Controlled Automatic Voltage Regulator (AVR) is to be used in TV Transmitters and with other transmission equipment so that the sensitive equipment are protected from low voltage / high voltage C;lnd power supply fluctuations and surges. 11. The AVR should be rugged, reliable and stable for continuous operation. 111. It should be naturally air cool type housed in one steel cubicle and hook at the top for lifting. IV. It should be from reputed manufacturer who are ISO 9001/ ISO 14001 certified. TECHNICAL SPECIFICATIONS: Value S.N. Parameter 2 Inputs 400 V, 3 Phase Nominal voltage 2.1 300V to 440V Range 2.2 48 to 52 Hz Frequency 2.3 Sinusoidal Waveform 2.4 3 Outputs 400 R.M.S. ±1.0%, 3 Phase Nominal voltagePhase 3.1 400 V to 410 V R.M.S. Settability 3.2 ± 1.0% Load regulation 3.3 ± 1.0% Line regulation 3.4 75 KVA Capacity 3.5 Sinusoidal Waveform 3.5 > 95% at full load, unity power 4 Efficiency and at mmllTIUm input factor voltage > 30 V/Second. Phase to phase. Correction speed 5 Switch on delay with timer and o to 60 seconds. 5.1 contactor 6 Protections 25% for half an hour. Overload capacity 6.1 Disconnecting the load 380V 6.2 Output under voltage through a contactor with alarm bell. the load 430 V, . Disconnecting 6.3 Over voltage through a contactor with alarm bell. Disconnecting the load through a 6.4 Over load tripping l ,' i contactor with alarm bell. Power factor effect Nil 6.5

~· · i

I

I

Page 83 of 88

DG:DD/TxD/10kW /2011/EV /

6.6 6.7

Waveform distortion Line noise suppression (for control circuit only) Metering

.

7

--.-.---.--

8

Indications

~_.-

9

Controls

_.___ __0.-_"._,"

10

Input/ Output terminations

11

12

Weight & Dimensions (LxBxH) Environmental specifications Ambient temperature range Storage temperature range Relative Humidity

Less than 1% at full load Line noise to be suppressed by at least 30dB"foc frequency range 10 MHz to 250 MHz (a)Digital voltmeter to be provided to \ read! ,input,! &\-~output R.M.S; Voltages of each phase or Phase-toPhase selected by selector switch. (b)Digital Ammeter to be provided to read current of, each phase selected by selector switch.· (a) LEDs for indicating (i) Input on. (ii) Out put ,on. '. (b) LED for indication of input power (i) LED for indicating low input. (ii) LED for indicating of input OK. (iii) LED for indication of high input. (a) Output On-Off through MCCB. (b) Auto- Manual switch selection. (c) Raise/lower the output voltage in manual mode. (d) Provision of AVR By pass III case of Malfunction. output & input (a) Suitable terminations should be provided. These terminals along with other distribution board output terminals shall be provided with acrylic sheet, so that these terminals are not accessible inadvertently. is to be terminal (b)Earthing provided. To be specified. by the. bidder

' ,t ··

12.1 12.2 12.3

5° C to + 45° C (operative) O°C to + 50°C. Max 90% NC at +40° C.

Page 84 of 88

DG:DD/TxD/10kW /2011/EV /

12.4 12.5 13 13.1 13.2 13.3 13.4

13.5 13.6

13.7

Maximum Altitude 1500 M T e of coolin Natural air Goolin Notes: Derating factor (adequate) should be applied to critical components while desi nin to im rove life ex ectanc . All the transformers and chokes must be varnish im re nated. All the com onents used should be of re uted make. PCB should be of glass epoxy material and heavy components & high power dissipating components like transformers, chokes, high power transformers should not be mounted directl on the PCB. AVR should be subjected to 100 hrs. Heat Run Test at max. load under normal ambient tern erature condition. AVR should be compatible & according to latest National and International standards on safety & EMC. Standards followed should be stated. Past supply record of manufacturer in supplying similar capacity AVR to other or anization may be attached .

.

·

.,

"I

,

: '.

1j (

!'..

I:

i

I;

· , '.'

.~ r

i \ '

··

,

,

··

I

,

'

~ ~.

I"

t ··· ,-.

.,'"

Page 85 of 88

DG:DD/TxD/IOkW /2011/EV /

Fig. 1 Signal Flow Diagram

_IR_D_I

C8lmd

VEA-l a:: &&J :I: _ '-'---1>~:1:

DVBSlS2DIL

g ,-.~

>

<I) ..( -(}-ON

~IR_D ~~o-o-j VEA-2

Audio inputs from IROs Video and audio test Inputs

VDAand ADA

-0

10kW TransmillB" wi1h(1+1)

o

-0-0~

X

VDAand ADA

Exciter

RF

monitoringPort

~:m-I l

AIItndOf

I-·--J-:..... f~

~

To Video Patch Panel To Audio Patch Panel

~

ILW~I

Page 86 of 88

DG: DD/TxD/l0kW

/2011/EV /

Fig. 2 System Diagram

3 Plus.. 4MVAC

75kVA

bobtioon

x-r

,J::j ~ ---L=S-~-7L

,i-~~~;;:'~-l ,

~_~~. i

,',

Input, Mioniborinl!' & M"""urinl!' sysn-

. IIkWT"

G!J-Power Metering

.

, I

Page 87 of 88

DG: DD/TxD/10kW /2011/EV /

Fig. 3 Details of 7 - Port Patch Panel

11

C:~)

To Dummy Load

Page 88 of 88

Information