Read PR24-PR26.pdf text version

PR24

A C C E P T O R ® S E R I E S · P L U G S A N D R E C E P TA C L E S UGR/UGP INTERCHANGEABLE BLADE STYLE

UGMG

Class I, Div. 1 & 2, Groups BM,C,D Class I, Zones 1 & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F,G Class III NEMA 3, 7 (B,C,D), 9 (F,G)

Listed File No. E91049 and/or E53660

Plug

Certified File No. LR14667

F E AT U R E S - S P E C I F I C AT I O N S · Flour and Feed Mills · Indoor or Outdoor Locations The ACCEPTOR® UGP/UGR Plug and Receptacle system, with its unique, patented design, is interchangeableM with other NEMA bladed type explosion-proof and dust ignition proof devices. The series has been tested and classified for use with CrouseHinds® Ark-Gard®2 and Appleton® ULine® plugs and receptacles in hazardous locations. Now available in GFCI version. See page PR27. How The Acceptor System Works ACCEPTOR receptacles contain an integral switch which must be closed to energize the circuit. The design permits only an approved plug to be energized. To actuate the switch, the plug must be inserted and rotated clockwise approximately 45o. The plug will lock into this position preventing accidental disengagement. To remove, simply push in then turn the plug counterclockwise and pull straight out. Plugs and receptacles may be used where interchangeable bladed devices are needed in locations made hazardous by the presence of flammable gases or vapors, combustible dusts or easily ignitable fibers and flyings. Plug can serve to provide power for portable equipment used in both hazardous and non-hazardous areas. Applications · Petroleum Refineries · Chemical Plants · Wet/Damp Areas · Corrosive Environments · Petroleum Plants · Grain Elevators Features · All external hardware is 316 stainless steel to provide low maintenance and long life · Factory sealed chamber in UGR receptacle contains switch's arcing components · No additional external seals are required, except in Group B applications

MExact models classified for interchangeability are listed in the information sheet provided with the products. Ark-Gard® is a registered trademark of Crouse-Hinds®. U-Line® is a registered trademark of Appleton Electric Company®.

· Receptacles are U.L. Listed as raintight. Proper sealing against moisture is assured · Spring loaded receptacle cover closes when plug is removed to provide protection when not in use · Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion · Electrostatically applied and baked powder epoxy/polyester finish

PLUG ACCEPTOR® plugs conform to NEMA configurations and can be used with standard receptacles in non-hazardous areas to maximize equipment utilization. The system's "turn to engage" feature

NEMA VOLTAGE CONFIGURATION CATALOG NUMBER 15 AMP PLUG

locks in plug and can be used to prevent accidental disengagement of critical equipment. Plugs for use with type S, SO, ST or STO heavy duty cord.

CATALOG NUMBER 20 AMP PLUG 20 AMP PLUG W/MESH GRIP

NEMA 15 AMP PLUG CONFIGURATION W/MESH GRIP

G

G

125VAC

W

UGP-15231

UGP-15231MG

W

UGP-20231

UGP-20231MG

5-15P

G

5-20P

G

250VAC

W

UGP-15232

UGP-15232MG

W

UGP-20232

UGP-20232MG

6-15P

NPlugs Rated Group B when used with properly rated & installed receptacles. See next page.

6-20P

1.51" 2.55"

1.69"

Plugs with mesh grips (page PR26) are shipped as component plug and grip.

A C C E P T O R ® S E R I E S · P L U G S A N D R E C E P TA C L E S UGR INTERCHANGEABLE BLADE STYLE

PR25

SWB-1, 2, 3

R E C E P TA C L E S A N D A S S E M B L I E S P NEMA RATING & CONFIGURATION

SWB-4, 5, 6

Single Gang

Double Gang

ENCLOSURE STYLE RECEPTACLE ONLY DEAD END

HUB SIZE -- 1/2" 3/4" 1" 1/2"

SINGLE GANGOP GROUPS C, D, F, & G UGRO-20231 UGR1-20231 UGR2-20231 UGR3-20231 UGR4-20231 UGR5-20231 UGR6-20231 UGROC-15231 UGR1C-15231 UGR2C-15231 UGR3C-15231 UGR4C-15231 UGR5C-15231 UGR6C-15231 UGRO-20232 UGR1-20232 UGR2-20232 UGR3-20232 UGR4-20232 UGR5-20232 UGR6-20232 UGROC-15232 UGR1C-15232 UGR2C-15232 UGR3C-15232 UGR4C-15232 UGR5C-15232 UGR6C-15232

DOUBLE GANGOP GROUPS C D, F, & G UGRO-20231 UGR7-20231 UGR8-20231 UGR9-20231 UGR10-20231 UGR11-20231 UGR12-20231 UGROC-15231 UGR7C-15231 UGR8C-15231 UGR9C-15231 UGR10C-15231 UGR11C-15231 UGR12C-15231 UGRO-20232 UGR7-20232 UGR8-20232 UGR9-20232 UGR10-20232 UGR11-20232 UGR12-20232 UGROC-15232 UGR7C-15232 UGR8C-15232 UGR9C-15232 UGR10C-15232 UGR11C-15232 UGR12C-15232

SINGLE GANGMN GROUPS B , C, D, F & G -- UGRB1-20231 UGRB2-20231 UGRB3-20231 UGRB4-20231 UGRB5-20231 UGRB6-20231 -- UGRB1C-15231 UGRB2C-15231 UGRB3C-15231 UGRB4C-15231 UGRB5C-15231 UGRB6C-15231 -- UGRB1-20232 UGRB2-20232 UGRB3-20232 UGRB4-20232 UGRB5-20232 UGRB6-20232 -- UGRB1C-15232 UGRB2C-15232 UGRB3C-15232 UGRB4C-15232 UGRB5C-15232 UGRB6C-15232

20 Amp 125 Volt

2 POLE 3 WIRE R

FEED-THRU RECEPTACLE ONLY DEAD END

3/4" 1" -- 1/2" 3/4" 1" 1/2"

5-20R 15 Amp 125 Volt

2 POLE 3 WIRE Q FEED-THRU RECEPTACLE ONLY DEAD END 2 POLE 3 WIRE R FEED-THRU RECEPTACLE ONLY DEAD END 2 POLE 3 WIRE Q FEED-THRU

PR

3/4" 1" -- 1/2" 3/4" 1" 1/2" 3/4" 1" -- 1/2" 3/4" 1" 1/2" 3/4" 1"

5-15R 20 Amp 250 Volt

6-20R 15 Amp 250 Volt

6-15R

MItems in this column are suitable for Class I, Group B in addition to Class I, Groups C, D. Also suitable for Class I, Zone 1, Groups IIB+H2, IIA. NSeals must be installed within 6 inches of conduit opening. OItems in this column may also be used in Class I, Zone 1, Groups IIB, IIA. Assembly numbers not rated for Group B are shipped as receptacle & back box components. PRefer to Killark Product Catalog page C29 for additional SWB Series Back Box configurations. QCanada only configuration RCanadian Codes now allow "T" combination slots for 15A or 20A plugs. Check breaker and wire feed size for proper application ratings. NOTE: For replacement receptacle cover and hinge, order KIT-173.

PR25A

^ ` ` b m q l o ® p b o f b p · m i r d p ^ k a o b ` b m q^ ` i b p rdo` `lkkb`qlop

Class I, Div. 1 & 2, Groups B,C,D Class I, Zones 1 & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F,G Class III NEMA 3, 4X*

Connector with Breech-Lock Cap

"3rd Hand" Plug Operation

Certified File No. LR14667

c b ^q r o b p J p m b ` f c f ` ^q f l k p Industrial Applications · Petroleum Refineries · Chemical/Petrochemical Plants · Oil Rigs & Platforms · Wet/Corrosive Environments · Grain Elevators Dimensions

8.25

CONNECTORS The ACCEPTOR® UGRC Connector complements UGP/UGR Plugs and Receptacles, as well as Ground Fault Protected UGFI and UGRGF Models. Used with Acceptor plugs, connectors can extend the reach for hazardous location rated portable equipment such as hand lamps. Connectors eliminate the need for user created corded box mounted receptacles. UGRC Connectors are interchangeable and classified for use with other NEMA bladed type explosion-proof and dust ignition proof plugs, including Crouse-Hinds® Ark-Gard®2 and Appleton® ULine®. Features · Available with the exclusive Breech-Lock Cap (see PR3 for more info) - patented notch provides "3rd hand" plug operation (holds lid open while one hand operates plug, and other holds connector). · Factory Sealed Construction · Suitable for 14 or 12 gauge SOOW or similar cable · Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion · Electrostatically applied and baked powder epoxy/polyester finish · Dead Front Construction with integral switch - requires Hazardous Rated NEMA Bladed plug for operation

Ark-Gard® is a registered trademark of Crouse-Hinds® U-Line® is a registered trademark of Appleton Electric Company®

3.69

2.88

UGRC Connector Breech cap model shown, Flip cap model dimensions are similar

Connector shown with Acceptor UGRP receptacle mounted in explosion proof Quantum® enclosure

Flip Cap

UGP Plug NEMA CONFIGURATION

20 Amp 125 Volt 2 POLE 3 WIRE

125V CONNECTOR CAP STYLE

CATALOG NUMBER

WEATHER RATING

Breech-Lock with Notch Flip Type Killark 125V Plugs 20 Amp 15 Amp

250V CONNECTOR CAP STYLE

UGRC-20231B UGRC-20231F UGP-20231 UGP-15231 UGRC-20232B UGRC-20232F UGP-20232 UGP-15232

N4X* N3**

5-20R with T-slots

20 Amp 250 Volt 2 POLE 3 WIRE

6-20R with T-slots

Breech-Lock with Notch Flip Type Killark 250V Plugs 20 Amp 15 Amp

N4X* N3**

G_êÉÉÅÜ Å~é ãçÇÉäë kQu ïáíÜ äáÇ ÅäçëÉÇ ~åÇ íìêåÉÇI kP tÜÉå mäìÖ áåëÉêíÉÇ eáåÖÉ ré GGcäáé iáÇ ãçÇÉäë kP ïáíÜ ÜáåÖÉ áå rm éçëáíáçå ïáíÜ çê ïáíÜçìí éäìÖ oÉéä~ÅÉãÉåí `~é ~åÇ eáåÖÉ háíëW _êÉÉÅÜ hfqJNTP_I cäáé hfqJNTP `p^ ÅÉêíáÑáÉÇ Ñçê `~å~åÇ~ ~åÇLçê çíÜÉê àìêáëÇáíáçåë ~ÅÅÉéíáåÖ `p^K

^ ` ` b m q l o ® p b o f b p · m i r d p ^ k a o b ` b m q^ ` i b p r d o m m^ k b i j l r k q o b ` b m q^ ` i b p

PR25B

Class I, Div. 1 & 2, Groups B,C,D Class I, Zones 1 & 2, Groups IIB+H2, IIA Class II, Div. 1 & 2, Groups F,G Class III NEMA 3, 4X*

Breech Cap Model

Typical Installation

C

US Certified File No. LR14667

c b ^q r o b p J p m b ` f c f ` ^q f l k p Industrial Applications · Petroleum Refineries · Chemical/Petrochemical Plants · Oil Rigs & Platforms · Wet/Corrosive Environments · Grain Elevators * UGRP Receptacles are available "Factory Installed" in the following series: Enclosures - Series EXB, B7E Distribution Equipment -Series D2L, B7L Lighting Panelboards * Contact factory for ordering information

Flip Lids

PANEL RECEPTACLES The ACCEPTOR® UGRP Panel Receptacle complements UGP/UGR Plugs and Receptacles, as well as Ground Fault Protected UGFI and UGRGF Models. Used with Acceptor plugs, panel receptacles provide local power for hazardous location rated portable equipment such as hand lamps. Units are suitable for Class I Div. 1 or Class I Div.2 depending on the enclosure type used . UGRP Panel Receptacles are interchangeable and classified for use with other NEMA bladed type explosion-proof and dust ignition proof plugs, including Crouse-Hinds® Ark-Gard®2 and Appleton® ULine®. Features · Available with the exclusive Breech-Lock Cap (see PR3 for more info) - patented notch provides "3rd hand" plug operation (holds lid open while one hand operates plug, and other holds connector). · Factory Sealed Construction · Copper-free aluminum (less than 4/10 of 1%) alloy resists corrosion · Electrostatically applied and baked powder epoxy/polyester finish · Dead Front Construction with integral switch - requires Hazardous Rated NEMA Bladed plug for operation

Ark-Gard® is a registered trademark of Crouse-Hinds® U-Line® is a registered trademark of Appleton Electric Company®

Breech Caps

Typical CLI Div. I application

Typical CLI Div. 2 application

Dimensions

4.50

3.69 2.94

Breech Lid

NEMA CONFIGURATION

Flip Cap

125V PANEL RECEPTACLE CAP STYLE

Breech Cap model shown. Flip Cap model dimensions are similar CATALOG NUMBER WEATHER RATING

20 Amp 125 Volt 2 POLE 3 WIRE

Breech-Lock with Notch Flip Type Killark 125V Plugs*** 20 Amp 15 Amp

250V PANEL RECEPTACLE CAP STYLE

UGRP-20231B URGP-20231F UGP-20231 UGP-15231 UGRP-20232B UGRP-20232F UGP-20232 UGP-15232

N4X* N3**

5-20R with T-slots

Breech-Lock with Notch 20 Amp Flip Type 250 Volt Killark 250V Plugs*** 2 POLE 20 Amp 3 WIRE 15 Amp 6-20R with T-slots

N4X* N3**

G_êÉÉÅÜ Å~é ãçÇÉäë kQu ïáíÜ äáÇ ÅäçëÉÇ ~åÇ íìêåÉÇI kP tÜÉå mäìÖ áåëÉêíÉÇ eáåÖÉ ré GGcäáé iáÇ ãçÇÉäë kP ïáíÜ ÜáåÖÉ áå rm éçëáíáçå ïáíÜ çê ïáíÜçìí éäìÖ GGGpÉÉ moOQ Ñçê mäìÖ kbj^ aá~Öê~ã ~åÇ aáãÉåëáçåë oÉéä~ÅÉãÉåí `~é ~åÇ eáåÖÉ háíëW _êÉÉÅÜ hfqJNTP_I cäáé hfqJNTP `ä~ëë f aáîK f _I`Ia áå ÉåÅäçëìêÉë ÅÉêíáÑáÉÇ íç POR ÉñéäçëáîÉ mpfK `ä~ëë f aáîK O áå ëí~åÇ~êÇ äçÅ~íáçå ÉåÅäçëìêÉë ìëáåÖ çåäó åçåJ~êÅáåÖ ÅçãéçåÉåíëK Å`p^ìë `ÉêíáÑáÉÇ Ñçê råáíÉÇ pí~íÉëI `~å~Ç~I ~åÇ çíÜÉê àìêáëÇáÅíáçåë ~ÅÅÉéíáåÖ íÜÉ ã~êâK

PR26

A C C E P T O R ® S E R I E S · P L U G S A N D R E C E P TA C L E S ADAPTER AND ACCESSORIES

UGMG

UGRA

XHL

XHLF

UGRGF

F E AT U R E S - S P E C I F I C AT I O N S UNIVERSAL ADAPTER KIT ACCEPTOR® receptacles are available with an adapter kit for mounting to Crouse-Hinds® EDS Series or Appleton® EFD Series back boxes. ACCEPTOR receptacles properly installed with these adapter kits are U.L. Listed for use in Class I, Div. 2, Groups B,C,D hazardous locations and Zone II, Groups IIB + H2, IIA. Kit contains one ACCEPTOR® receptacle plus adapter plate and mounting bolts.

UGRA ADAPTER KIT NEMA RATING & CONFIGURATION ADAPTER KIT CATALOG NUMBER

XHL SERIES HAND LAMPS A handy accessory to the ACCEPTOR® Series, these hand lamps can be used as an illumination source where flammable materials are present, such as processed finish goods, storage vats, or handling areas. See page L16 for detailed information and features.

XHL INCANDESCENT CATALOG NUMBER XHL-100 XHL-GL XHLG XHLS DESCRIPTION Handlamp Replacement globe Replacement guard Replacement socket

20 Amp 125 Volt

2 POLE 3 WIRE UGRA-20231

XHL Incandescent Class I, Div. 1 & 2, Groups C,D Class l, Zones 1 & 2, Groups llB,llA

Listed File No. E97760 Certified File No. LR10019

5-20R 20 Amp 250 Volt

2 POLE 3 WIRE UGRA-20232

GFI PROTECTED RECEPTACLE Utilizes FXS GFI and ACCEPTOR® receptacle to interrupt a circuit, when a ground fault is detected on equipment which may be handled by personnel in hazardous locations. Features · Test and Reset push buttons are provided on cover assembly, with optional pilot light availableM Unit should be tested monthly · Includes new GFCI to meet latest UL943 GFCI standards revisions · Exterior gasket provides NEMA 3 weatherproof protection · Ground boss for grounding in the splice box · Color coded wiring and stainless steelcover bolts · Receptacle used is UGRO-20231. See page PR25

NEMA RATING & ENCLOSURE HUB CONFIGURATION STYLE SIZE 1/2" Dead End 3/4" Dead End 20A, 125V, 2P, 3W Dead End 1" 1/2" Feed Thru 3/4" Feed Thru 1" Feed Thru CATALOG NUMBER UGRGF107 UGRGF108 UGRGF109 UGRGF110 UGRGF111 UGRGF112

XHLF FLUORESCENT

CATALOG NUMBER DESCRIPTION Fluorescent hand lamp Fluorescent hand lamp with 50' of 16/3 SOW cord and 15A Acceptor plug XHLF26 XHLF26-50KP

6-20R

Listed File No. E91049 Certified LR14667

OPTIONAL STRAIN RELIEF GRIP FOR UGP PLUGS Stainless steel grips for cable strain relief or bend control.

CATALOG NUMBER UGMG DESCRIPTION Mesh grip

XHLF Fluorescent Class I, Div. 1 & 2, Groups C,D Class l, Zones 1 & 2, Groups llB,llA Class lI, Div. 1 & 2, Groups E,F,G

c

Electrical Rating GFI units are rated at 20A, 120 VAC, 60Hz. Class A. 4-6 miliamp trip setting Trip Time-UL Curve Class I, Div. 1 & 2, Groups C,D Class l, Zones 1 & 2, Groups llB,llA Class lI, Div. 1 & 2, Groups E,F,G Class III NEMA 3, 7(C,D) 9(E,F,G)

Certified LR11714 See files for details or call Killark. M For LED pilot light indica tor of live circuit, add "PL" for Red or "PLG" for green. Example - UGRGF107-PL.

Listed File No. E97760

Information

PR24-PR26.pdf

5 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

1337650