Read Catalog Cover 2008 Setup.qxp text version

About SJE-Rhombus®

For over 30 years, SJE-Rhombus® has worked hard to become one of the most trusted names in the water, wastewater and embedded control industries by bringing you products that offer reliability and performance that you can depend on. Located just outside of Detroit Lakes, Minnesota (the heart of the lakes region in West Central Minnesota), SJE-Rhombus® occupies over 65,000 square feet of manufacturing and warehouse facilities.

Top: Since 1975, SJE-Rhombus has grown to over 65,000 sq. ft. of manufacturing and warehouse facilities. Right: Products endure extensive in-house testing before entering the field. Bottom Right: Service does not stop with the sale of a product contact our friendly staff for questions. Recently honored as one of the 50 Best Small/Medium Companies to Work for in America, SJE-Rhombus employee-owners take great pride in the quality products and service that SJE-Rhombus offers. Because SJERhombus is 100% employee-owned, each employee has a personal stake in making the best possible product in the industry. After all, our success is measured by your satisfaction. SJE-Rhombus offers a wide variety of control products for residential, commercial, municipal, and industrial markets. From control panels utilizing embedded circuit board technology, to complete control/monitoring systems designed and built to individual specifications, SJE-Rhombus represents the most reliable integration of engineering and manufacturing capabilities in the industry. New product designs endure extensive in-house and field testing before submittal to recognized independent laboratories for safety testing and approval. This commitment to quality ensures you a dependable, trouble-free product. SJE-Rhombus offers a three-year limited warranty on all standard catalog products. SJE-Rhombus offers the best oneon-one customer service in the industry. We have an experienced, knowledgeable, and friendly team committed to providing you exceptional product support. If you have product questions or need troubleshooting assistance, please contact Customer Service toll free at:

1-888-DIAL-SJE (1-888-342-5753) 1-800-RHOMBUS (1-800-746-6287)

www.sjerhombus.com

Don't Stress! Use Panel Express! SJE-Rhombus offers expedited shipping on most Build-A-PanelTM products. Visit www.sjerhombus.com or contact Customer Service to learn more about getting your panel as fast as the next day.

New Training CD on SJE-Rhombus Products!

Get your FREE copy of the NEW SJE-Rhombus Introductory Product Training CD!

Pop this new informational CD into your computer and watch how float switches, alarms systems and control panels function. Learn the basics of each product and what features SJE-Rhombus offers. Call Customer Service today for your FREE copy! Toll Free: 1-888-DIAL-SJE (342-5753) Or visit www.sjerhombus.com to view with a high speed internet connection!

Table of Contents

CONTROL PANELS

Installer Friendly SeriesTM

IFS IFS IFS IFS IFS IFS Single Phase Simplex (Demand/TD) Single Phase Duplex (Demand/TD) Three Phase Simplex Three Phase Duplex Single Phase Simplex Capacitor Start/Run Single Phase Duplex Capacitor Start/Run 3 5 7 9 11 13 Tank Alert® ABW Tank Alert® I Tank Alert® XT Tank Alert® Duo Tank Alert® 4X 63 65 67 69 71

PUMP SWITCHES

SJE PumpMaster® SJE PumpMaster® Plus SJE PumpMaster® Plus SPDT Double Float® Master SJE AmpMaster® SJE VerticalMaster® SJE MicroMaster® AC/DC Junior Super Single® Super Single® Double Float® 73 75 77 79 81 83 85 87 89 91

Single Phase Simplex

Model 111 Model 115 Model 112 15 17 19

Single Phase Duplex

Model 122 21

Three Phase Simplex

Model 312 23

CONTROL SWITCHES

SJE SignalMaster® SJE SignalMaster® SPDT SJE MilliAmpMasterTM Sensor Float® Sensor Float® Mini 93 95 97 99 101

Three Phase Duplex

Model 322 25

Capacitor Start/Run

Model SGS Model 113 Model 123 27 29 31

ACCESSORIES

Junction Box Junction Box Price Worksheet Accessories

Cable Weight, Hub Assembly, Float Brackets, Cable Connectors, Cord Seal, Cable Clamp Assembly, Pressure Transducers, Anchor, Chain, & Vertical Reed Switch

103 105 107

Intrinsically Safe

Model Model Model Model 114 124 314 324 33 35 37 39

Home Protection Products

Auto Dialer & Home Temperature Monitor

109

INSTALLATION INSTRUCTIONS

JB Plugger 111 Tank Alert® AB 113 115 Tank Alert® ABP Tank Alert® ABW 117 Tank Alert® I 121 123 Tank Alert® XT Tank Alert® XT Terminal Block Option 125 Tank Alert® Duo 127 Tank Alert® 4X 129 Pump Switches 131 Double Float® Master/Double Float® 133 SJE VerticalMaster® 135 Control Switches 137 SJE MilliAmpMasterTM/SJE MicroMaster® AC/DC 139 Junction Box 141 Accessories 143 Vertical Reed Switch 145

Timed Dosing

Model TD Model DTD Model PS 41 43 45

Drip Irrigation

IFS Drip Model DP 47 49

Plugger Products

Model RP JB Plugger PS PatrolTM 51 53 55

Water Well

Model 126 57

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 · 1-218-847-4617 Fax email: [email protected]

LIQUID LEVEL ALARMS

Tank Alert® AB Tank Alert® ABP 59 61

www.sjerhombus.com

1

Ordering Information

To assist us in delivering the exact product you want, please order by the seven digit part number or panel model number. If you require special features, such as additional cable length or special packaging, please call your customer service representative at 1-888-DIAL-SJE (1-888-342-5753). SJE-Rhombus® also manufactures Engineered Custom control panels. Please contact SJE-Rhombus customer service to request a custom panel quote at 1-800-RHOMBUS (1-800-746-6287) or 1-888-DIAL-SJE (1-888-342-5753). For additional information on our Blanket Agreement Program, Freight Paid Program, Return Policy or Payment Terms, please refer to the back side of your multiplier sheet, contact your factory representative or contact SJE-Rhombus customer service at 1-888-DIAL-SJE (1-888-342-5753).

SHIPPING YOUR ORDER

Standard catalog items, depending on volume and options, are shipped within four (4) business days from receipt of order. SJE-Rhombus ships in-stock items same day when requested. SJE-Rhombus Build-A-PanelTM control panels ordered with multiple options and orders exceeding $10,000 may require up to ten (10) business days to ship. Large stocking panel orders or custom panel orders may require additional lead time of more than ten (10) business days. Next Day Air, Second Day Air and Three Day UPS Ground services are available. To receive these services you must place your order before 1:00 p.m. Central Time. SJE-Rhombus reserves the right to increase prices if transportation rates increase. SJE-Rhombus offers a Panel Express Program for expedited delivery on most control panels found in this catalog. Contact Customer Service for more information.

PRODUCT RETURN

Returned Materials Authorization (RMA) numbers must be assigned to products being returned for warranty claim. Control panel models SGS, 113, 123, 114, 124, 314, panels including the option "10A", panels with any non-catalog options, obsolete panels, and panels more than one year from date of manufacture cannot be returned to SJE-Rhombus for restocking credit. Contact your customer service representative for instructions on returning a product for warranty.

PRICING SUBJECT TO CHANGE WITHOUT NOTICE.

Three-Year Limited Warranty*

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus. THE THREE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJERHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. This warranty does not apply to: (a) damage due to lightning or conditions beyond the control of SJE-Rhombus; (b) defects or malfunctions resulting from units not installed, operated, or maintained in accordance with instructions provided, applicable local codes, ordinances, or accepted trade practices; (c) failures resulting from abuse, misuse, accident, or negligence; or (d) units repaired and/or modified without prior authorization from SJE-Rhombus. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-Rhombus, or such place as designated by SJE-Rhombus. Contact customer service at 1-888-DIAL-SJE (1-888-342-5753) for a Return Materials Authorization number (RMA) on any product being returned for a warranty claim. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS SHALL NOT, IN ANY MATTER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. *Engineered Custom panels carry a two-year limited warranty or as quoted.

2

Cat Page PN 1016795F © SJE-Rhombus Printed in USA 10/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Single Phase Simplex (Demand/TD)

Single phase, simplex demand dose or timed dose, float controlled system for pump control and system monitoring. The IFS simplex control panel is designed to control one 120, 208, 240 VAC single phase pump in water and sewage installations. The IFS control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation. The panel configuration can be easily converted in the field to either a timed dose or demand dose by a simple jumper change, and by adding a display board (timed dose only) for programming pump ON/OFF times.

G C D A B

F E

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons control pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pump Run Indicator will illuminate when pump is called to run. Seven-Segment LED Display shows mode, pump elapsed time (hh:mm), events (cycles), alarm counter, timed dose override counter, and ON/OFF times. (Display is standard on timed dose and optional on demand dose.) Next Push Button when pressed toggles display through: mode, elapsed time meter, cycle counter, and alarm counter. Timed dose mode also provides override counter and pump ON/OFF times. Repeat Cycle Timer Display Push Buttons when pressed sets pump ON/OFF times (timed dose only).

J

H

I

Model Shown IFS11W904X8AC (Inner door view)

1 2

7 3

5

9 11

8

6

I.

4 10

J.

Model Shown IFS11W904X8AC (Inside view)

Reg. Cdn Pat. & TM Off

Note: LED display will turn off after one minute of not being used.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes: Demand Dose - three 20' Sensor Float® control switches Timed Dose - two 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PANEL COMPONENTS

1. Enclosure base measures 10 X 8 X 4 inches (25.4 X 20.32 X 10.16 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options, voltage, and amp range selected may change enclosure size and component layout. Red Alarm Beacon provides 360° visual check of alarm condition. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Circuit Breaker (optional) provides pump disconnect and branch circuit protection. Power Relay controls pump by switching electrical line(s). Definite purpose contactors used when pump full load amps are above 15. Float Connection Terminal Block Large Incoming Power/Pump Connection Terminal Block Terminal Block Installation Labels

2. 3.

4. 5. 6. 7. 8. 9.

10. Ground Lug 11. Alarm Activation Relay NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

3

CONTROL PANELS

IFS MODEL IFS

MODEL TYPE

1

W

1 = SPLX TIMED DOSE (includes option 8AC standard) ........................................................................... $725.00 2 = SPLX DEMAND DOSE ........................................................................................................................ $650.00

________

ALARM PACKAGE

1 = alarm package (includes test/normal/silence switch, fuse, red light & horn) ............................................ Base

ENCLOSURE RATING

W = NEMA 4X ................................................................................................................................................. Base

STARTING DEVICE

1 = 120/208/240 VAC .................................................................................................................................... Base 9 = 120 VAC .................................................................................................................................................. Base

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................... Base 1 = 7-15 FLA ................................................................................................................................................. Base 2 = 15-20 FLA ............................................................................................................................................ $80.00 ________

PUMP DISCONNECTS

0 = no pump disconnect ................................................................................................................................ Base 4 = circuit breaker 120 VAC (must select starting device option 9) ................................................................................... $35.00 120/208/240 VAC (must select starting device option 1) ..................................................................... $70.00

________

SWITCH APPLICATIONS

H = floats (Timed dose = low level and alarm / Demand dose = stop, start, and alarm) ................................. Base X = no float timed dose .......................................................................................................................................... -$50.00 demand Dose ..................................................................................................................................... -$75.00 Note: Pump down applications only.

________

OPTIONS Listed below

Total Options TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

3A Alarm flasher .............................................................. $50.00 3B Manual reset alarm .................................................... $25.00 4A Redundant off .............................................................. $0.00 (select option 4D if floats are required) 4D Redundant off float - 20 ft. Sensor Float® ................ $25.00 6A Auxiliary alarm contacts, form C ............................... $40.00 8AC Display board includes: ETM counter, events (cycles) counter, alarm counter, and override counter (timed dose only). Display board also required for changing a demand dose panel to timed dose panel. Demand Dose .......................................................... $100.00 Timed Dose (included as standard) .......................... $0.00 10E Lockable latch - NEMA 4X ......................................... $40.00 10F Lightning arrestor (control and alarm power combined) .................... $160.00

10K Anti-condensation heater .................................... $100.00 11C NEMA 1 remote alarm panel (must select option 6A) ......................................... $65.00 11D NEMA 4X remote alarm panel (must select option 6A) ....................................... $170.00 15A Control / Alarm circuit breaker ............................... $35.00 16A 10' cord in lieu of 20' (per float) .............................. -$2.00 16B 15' cord in lieu of 20' (per float) .............................. -$1.00 16C 30' cord in lieu of 20' (per float) ............................... $5.00 16D 40' cord in lieu of 20' (per float) ............................. $15.00 17C Sensor Float® / internally weighted (per float) ... $5.00 17D Sensor Float® / externally weighted (per float) .. $7.00 17G MilliAmpMasterTM/ pipe clamp (per float) .............. $0.00 17H MilliAmpMasterTM/ externally weighted (per float) $7.00 18A Timer override option with float (timed dose only) $25.00

Mechanically-activated V Mercury-activated

SAMPLE

MODEL IFS 1 1 W 9 1 4 H 8AC 10E

LIST PRICE Model Type Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnects Switch Application Options: Display, Lockable Latch IFS1 .......... $725.00 1 ............... Base W ............... Base 9 ............... Base 1 ............... Base 4 ............ $35.00 H ............... Base 8AC .............. $0.00 10E ............ $40.00 $800.00

TOTAL LIST PRICE

4

Cat Page PN 1016769G © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Single Phase Duplex (Demand/TD)

Single phase, duplex demand dose or timed dose, float controlled system for pump control and system monitoring.

The IFS duplex control panel is designed to control two (alternating) 120, 208, 240 VAC single phase pumps in water and sewage installations. The IFS control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation. The panel configuration can be easily converted in the field to either a timed dose or demand dose by a simple jumper change, and by adding a display board (timed dose only) for programming pump ON/OFF times.

F F E G H I J K G C D E A B

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. I. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons controls pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pump Run Indicators will illuminate when pump(s) is called to run. Lead/Lag Selector (with display board only) toggles pump operation, alternate, 1-2 and 2-1 operation. Seven-Segment LED Display shows mode, pumps elapsed time (hh:mm:ss), events (cycles), alarm counter, timed dose override counter, and ON/OFF times. (Display is standard on timed dose and optional on demand dose.) Next Push Button when pressed toggles display through: mode, elapsed time meters, lead/lad selector, cycle counters, and alarm counter. Timed dose mode also provides override counter and pump ON/OFF times. Repeat Cycle Timer Display Push Buttons when pressed sets pump ON/OFF times (timed dose only).

Model Shown IFS31W904X8AC (Inner door view)

1 2

7 3

5

9 11

8

6

4 10

J.

Model Shown IFS31W904X8AC (Inside view)

Reg. Cdn Pat. & TM Off

K.

Note: LED display will turn off after one minute of not being used.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes: Demand Dose - three 20' Sensor Float® control switches Timed Dose - two 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PANEL COMPONENTS

1. Enclosure base measures 12 X 10 X 6 inches (30.48 X 25.4 X 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options, voltage, and amp range selected may change enclosure size and component layout. Red Alarm Beacon provides 360° visual check of alarm condition. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Circuit Breakers (optional) provide pump disconnect and branch circuit protection. Power Relays control pump by switching electrical line(s). Definite purpose contactors used when full load amps are above 15. Float Connection Terminal Block Large Incoming Power/Pump Connection Terminal Block Terminal Block Installation Labels

2. 3.

4. 5. 6. 7. 8. 9.

10. Ground Lugs 11. Alarm Activation Relay NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

5

CONTROL PANELS

IFS MODEL IFS

MODEL TYPE

1

W

3 = DPLX TIMED DOSE (includes option 8AC standard) ........................................................................... $879.00 4 = DPLX DEMAND DOSE ......................................................................................................................... $804.00

________

ALARM PACKAGE

1 = alarm package (includes test/normal/silence switch, fuse, red light & horn) ............................................ Base

ENCLOSURE RATING

W = NEMA 4X ................................................................................................................................................. Base

STARTING DEVICE

1 = 120/208/240 VAC .................................................................................................................................... Base 9 = 120 VAC .................................................................................................................................................. Base

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................... Base 1 = 7-15 FLA ................................................................................................................................................. Base 2 = 15-20 FLA .......................................................................................................................................... $105.00 ________

PUMP DISCONNECTS

0 = no pump disconnect ................................................................................................................................ Base 4 = circuit breaker(s) 120 VAC (must select starting device option 9) ................................................................................... $70.00 120/208/240 VAC (must select starting device option 1) ................................................................... $140.00

________

SWITCH APPLICATIONS

H = floats (Timed dose = low level and alarm / Demand dose = stop, start, and lag/alarm) ............................ Base X = no float timed dose .......................................................................................................................................... -$50.00 demand Dose ..................................................................................................................................... -$75.00 Note: Pump down applications only.

________

OPTIONS Listed below

Total Options TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

3A Alarm flasher .............................................................. $50.00 3B Manual reset alarm .................................................... $25.00 4A Redundant off .............................................................. $0.00 (select option 4D if floats are required) 4D Redundant off float - 20 ft. Sensor Float® ................ $25.00 6A Auxiliary alarm contacts, form C ............................... $40.00 8AC Display board includes: ETM counters, events (cycles) counter, alarm counter, override counter (timed dose only), and lead/lag selector switch. Display board also required for changing a demand dose panel to timed dose panel. Demand Dose .......................................................... $100.00 Timed Dose (included as standard) .......................... $0.00 10E Lockable latch - NEMA 4X ......................................... $40.00 10F Lightning arrestor (pump breakers required, control and alarm power combined) .......................................... $160.00

10K Anti-condensation heater ..................................... $100.00 11C NEMA 1 remote alarm panel (must select option 6A) .......................................... $65.00 11D NEMA 4X remote alarm panel (must select option 6A) ........................................ $170.00 15A Control / Alarm circuit breaker ................................ $35.00 16A 10' cord in lieu of 20' (per float) ............................... -$2.00 16B 15' cord in lieu of 20' (per float) ............................... -$1.00 16C 30' cord in lieu of 20' (per float) ................................ $5.00 16D 40' cord in lieu of 20' (per float) .............................. $15.00 17C Sensor Float® / internally weighted (per float) .... $5.00 17D Sensor Float® / externally weighted (per float) ... $7.00 17G MilliAmpMasterTM/ pipe clamp (per float) ............... $0.00 17H MilliAmpMasterTM/ externally weighted (per float) $7.00 18A Timer override option with float (timed dose only) $25.00 19F Fourth float to separate alarm function from lag (demand dose only) ................................................. $25.00

Mechanically-activated V Mercury-activated

SAMPLE

MODEL IFS 3 1 W 9 1 4 H 8AC 10E

LIST PRICE Model Type Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnects Switch Application Options: Display, Lockable Latch IFS3 .......... $879.00 1 ............... Base W ............... Base 9 ............... Base 1 ............... Base 4 ............ $70.00 H ............... Base 8AC .............. $0.00 10E ............ $40.00 $989.00

TOTAL LIST PRICE

6

Cat Page PN 1016770G © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Three Phase Simplex

Three phase, simplex demand dose, float controlled system for pump control and system monitoring. The IFS three phase simplex control panel is designed to control one 208, 240, or 480 VAC three phase pump in water and sewage installations. The IFS three phase simplex control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation.

C D A B

F E G H

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. I. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons control pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pump Run Indicator will illuminate when pump is called to run. Seven-Segment LED Display shows mode, pump elapsed time (hh:mm), events (cycles), alarm counter and pump fail counter. (Display is optional.) Next Push Button when pressed toggles display through: mode, elapsed time meter, cycle counter, alarm counter, and pump fail counter.

9 6 12 4 1 2

I

Model Shown IFS51W001X8AC (Inner door view)

5

3 11

Note: LED display will turn off after one minute of not being used.

PANEL COMPONENTS

1. Enclosure measures 12 x 10 x 6 inches (30.48 x 25.40 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Red Alarm Beacon provides 360° visual check of alarm condition. IEC Motor Contactor controls pump by switching electrical lines. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/ alarm voltage. Motor Protective Switch provides adjustable overload, branch circuit protection and pump disconnect. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Float Connection Terminal Block Large Incoming Power Connection Terminal Block

7 8 10

Model Shown IFS51W001X8AC (Inside view)

Reg. Cdn Pat. & TM Off

2. 3. 4. 5. 6.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

7. 8. 9.

10. Terminal Block Installation Label 11. Ground Lug 12. Alarm Activation Relay NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

7

CONTROL PANELS

IFS5

W

MODEL IFS5 .......................................................................................................................................... $1313.00

ALARM PACKAGE

1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) .................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $45.00 13.0-18.0 FLA ................................................................................................................................... $45.00 17.0-23.0 FLA ................................................................................................................................... $55.00 20.0-25.0 FLA ................................................................................................................................... $55.00

________

FLOAT SWITCH APPLICATION

H = pump down ............................................................................................................................................... Base X = no floats .............................................................................................................................................. -$75.00

OPTIONS Listed below

Total Options TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

3A Alarm flasher ........................................................... $50.00 5A Thermal cutout/heat sensor auto reset ................. $40.00 (for pumps w/thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) ......... $160.00 6A Auxiliary alarm contacts, form C ............................ $40.00 8AC Display board includes: ETM counter, events (cycles) counter, alarm counter. ........................................ $100.00 10E Lockable latch - NEMA 4X ...................................... $40.00 10G Lightning arrestor ................................................. $160.00 10K Anti-condensation heater .................................... $100.00 11C NEMA 1 remote alarm panel (must select option 6A) ......................................... $65.00

11D NEMA 4X remote alarm panel (must select option 6A) ................................................ $170.00 16A 10' cord in lieu of 20' (per float) ....................................... -$2.00 16B 15' cord in lieu of 20' (per float) ....................................... -$1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17G SJE MilliAmpMasterTM/ pipe clamp (per float) ................ $0.00 17H SJE MilliAmpMasterTM/ externally weighted (per float) . $7.00

Mechanically-activated V Mercury-activated

SAMPLE

MODEL IFS 5 1 W 001 H 8AC 10E

LIST PRICE Model Type Alarm Package Enclosure Rating Pump Full Load Amps Switch Application Options: Display, Lockable Latch IFS5 ........ $1313.00 1 ............... Base W ............... Base 001 ............... Base H ............... Base 8AC .......... $100.00 10E ............ $40.00 $1453.00

TOTAL LIST PRICE

8

Cat Page PN 1018599D © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Three Phase Duplex

Three phase, duplex demand dose, float controlled system for pump control and system monitoring. The IFS three phase duplex control panel is designed to alternately control two 208, 240, or 480 VAC three phase pumps in water and sewage installations. The IFS three phase duplex control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation.

LAG

C D

A B

F

F E

ALARM

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. I. J. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons control pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pumps Run Indicators will illuminate when pumps are called to run. Select Push Button (with display board only) toggles pump operation, alternate 1-2 and 2-1 operation. Seven-Segment LED Display shows mode, pump elapsed time (hh:mm), events (cycles), alarm counter and pump fail. (Display is optional.) Next Push Button (with display board only) when pressed toggles display through: mode, elapsed time meter, lead/lag, cycle counters, alarm counter, and pump fail counter. Program Push Button (with display board only) when pressed puts panel in program mode.

4 9 12 6 1 G

LEAD

STOP

G H K

I J

Model Shown IFS61W001X8AC (Inner door view)

2

5

3 11

7 8 10

K.

Note: LED display will turn off after one minute of not being used.

Model Shown IFS61W001X8AC (Inside view)

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Red Alarm Beacon provides 360° visual check of alarm condition. IEC Motor Contactors controls pump by switching electrical lines. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/ alarm voltage. Motor Protective Switches provides adjustable overload, branch circuit protection and pump disconnect. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Float Connection Terminal Block Large Incoming Power Connection Terminal Block

Reg. Cdn Pat. & TM Off

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

2. 3. 4. 5. 6.

7. 8. 9.

10. Terminal Block Installation Label 11. Ground Lugs 12. Alarm Activation Relay NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

9

CONTROL PANELS

IFS6

W

MODEL IFS6 .......................................................................................................................................... $1733.00

ALARM PACKAGE

1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) .................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $60.00 13.0-18.0 FLA ................................................................................................................................... $60.00 17.0-23.0 FLA ................................................................................................................................... $80.00 20.0-25.0 FLA ................................................................................................................................... $80.00

________

FLOAT SWITCH APPLICATION

H = pump down ............................................................................................................................................... Base X = no floats .............................................................................................................................................. -$75.00

OPTIONS Listed below

ENCLOSURE UPSIZE - If you selected one or more of the options, add a one-time $50.00 list enclosure upsize

Total Options

________ ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION

LIST PRICE

CODE DESCRIPTION

Enclosure Upsize TOTAL LIST PRICE

LIST PRICE

3A Alarm flasher ........................................................... $50.00 5A Thermal cutout/heat sensor auto reset ................. $80.00 (for pumps w/thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) ......... $315.00 6A Auxiliary alarm contacts, form C ............................ $40.00 8AC Display board includes: ETM counter, events (cycles) counter, alarm counter and lead/lag selector switch. .................................................................. $100.00 10E Lockable latch - NEMA 4X ...................................... $40.00 10G Lightning arrestor ................................................. $160.00 10K Anti-condensation heater .................................... $100.00 11C NEMA 1 remote alarm panel (must select option 6A) ......................................... $65.00

11D NEMA 4X remote alarm panel (must select option 6A) ................................................ $170.00 16A 10' cord in lieu of 20' (per float) ....................................... -$2.00 16B 15' cord in lieu of 20' (per float) ....................................... -$1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17G SJE MilliAmpMasterTM/ pipe clamp (per float) ................ $0.00 17H SJE MilliAmpMasterTM/ externally weighted (per float) . $7.00 19F Fourth float to separate alarm function from lag ........... $25.00

Mechanically-activated V Mercury-activated

SAMPLE

MODEL IFS 6 1 W 001 H 8AC 10E

LIST PRICE Model Type Alarm Package Enclosure Rating Pump Full Load Amps Switch Application Options: Display, Lockable Latch IFS6 ........ $1733.00 1 ............... Base W ............... Base 001 ............... Base H ............... Base 8AC .......... $100.00 10E ............ $40.00 $1873.00

TOTAL LIST PRICE

10

Cat Page PN 1018980D © SJE-Rhombus Controls Printed in USA 11/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Single Phase Simplex Capacitor (Start/Run)

Single phase, simplex demand dose, float controlled system for pump control and system monitoring. The IFS single phase simplex capacitor (start/run) control panel is designed to control one 120, 208, or 240 VAC single phase pump in water and sewage installations. The IFS single phase simplex capacitor (start/run) control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation.

F E G H C D A B

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. I. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons control pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pump Run Indicator will illuminate when pump is called to run. Seven-Segment LED Display shows mode, pump elapsed time (hh:mm), events (cycles), alarm counter and pump fail counter. (Display is optional.) Next Push Button when pressed toggles display through: mode, elapsed time meter, cycle counter, alarm counter, and pump fail counter.

I

Model Shown IFS71W114X912A8AC (Inner door view)

1 10 12 2 3

7 4 11

Note: LED display will turn off after one minute of not being used.

5

8 9

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Red Alarm Beacon provides 360° visual check of alarm condition. IEC Motor Contactor controls pump by switching electrical lines. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Float Connection Terminal Block Large Incoming Power Connection Terminal Block Terminal Block Installation Label Ground Lugs

6

Model Shown IFS71W114X912A8AC (Inside view)

Reg. Cdn Pat. & TM Off

2. 3. 4.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

5. 6. 7. 8. 9.

10. Alarm Activation Relay 11. Capacitor Start Module - start/run capacitor kits must be ordered separately. 12. Circuit Breaker (optional) provides pump disconnect and branch circuit protection. NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

11

CONTROL PANELS

IFS7

W

1

MODEL IFS7 .......................................................................................................................................... $1050.00

ALARM PACKAGE

1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) .................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

STARTING DEVICE

1 = IEC motor contactor 120/208/240V .......................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA ........................................................................................................................................... $80.00 = 20-30 FLA ........................................................................................................................................... $90.00 = 30-40 FLA ......................................................................................................................................... $115.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker .................................................................................................................................. $ 70.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................ - $75.00

OPTIONS Listed below

Start/run capacitor kits must be ordered separately (see option 12 below or call factory)

Total Options

________ ________

................................................................................................................................. TOTAL LIST PRICE

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION

LIST PRICE

CODE

DESCRIPTION

LIST PRICE

3A Alarm flasher ................................................. $50.00 5A Thermal cutout/heat sensor auto reset ........ $40.00 (for pumps with thermal switch leads) 5E Seal fail circuit and indicator ....................... $160.00 6A Auxiliary alarm contact, form C .................... $40.00 8AC Display board includes: ETM counter, events (cycles) counter, alarm counter. ................ $100.00 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-30 FLA ........................................................ $60.00 30-40 FLA .................................................... $100.00 10E Lockable latch ................................................ $40.00 10F Lightning arrester ........................................ $160.00 10K Anti-condensation heater ........................... $100.00 11C NEMA 1 alarm panel ...................................... $65.00 (must select option 6A)

11D NEMA 4X alarm panel must select option 6A .............. $170.00 12B Customer supplied motor start components, mounted in enclosure by SJE-Rhombus .......................................... $110.00 12C Motor start component, mounted and supplied by SJE-Rhombus ........................................................... Call Factory 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ................. $5.00 17D Sensor Float® / externally weighted (per float) ............... $7.00 17G SJE MilliAmpMasterTM / pipe clamp (per float) .................... $0.00 17H SJE MilliAmpMaster TM / externally weighted (per float) ... $7.00

SAMPLE

MODEL IFS7 1 W 1 1 4 H 912A 12B

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Pump Overload, Motor Start Components Supplied by Customer

LIST PRICE IFS7 ...... $1050.00 1 ............. Base W ............. Base 1 ............. Base 1 ............. Base 4 .......... $70.00 H ............. Base 912A .......... $60.00 12B ........ $110.00 TOTAL LIST PRICE $1290.00

12

Cat Page PN 1019700C © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

INSTALLER FRIENDLY SERIESTM - IFS Single Phase Duplex Capacitor (Start/Run)

Single phase, duplex demand dose, float controlled system for pump control and system monitoring. The IFS single phase duplex capacitor (start/run) control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage installations. The IFS single phase duplex capacitor (start/run) control panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring pump and float operation

LAG

C D

A B

F

F E

ALARM

LEAD

TOUCH PAD FEATURES

A. B. C. D. E. F. G. H. I. J. Control Power Indicator/Fuse. Indicator light will illuminate if control power is present in panel. Control Fuse Replace Indicator will illuminate if control fuse is blown. Alarm will activate if control fuse is blown. Alarm Power Indicator/Fuse. Indicator light will illuminate if alarm power is present in panel. Alarm Fuse Replace Indicator will illuminate if alarm fuse is blown. Float Indicators will illuminate when floats are activated. Alarm will activate if a float operates out of sequence and the appropriate float indicator will flash. HOA (Hand-Off-Automatic) Buttons control pump mode with indication. Hand mode defaults to Automatic when stop level is reached. Pumps Run Indicators will illuminate when pumps are called to run. Select Push Button (with display board only) toggles pump operation, alternate 1-2 and 2-1 operation. Seven-Segment LED Display shows mode, pump elapsed time (hh:mm), events (cycles), alarm counter and pump fail. (Display is optional.) Next Push Button (with display board only) when pressed toggles display through: mode, elapsed time meter, lead/lag, cycle counters, alarm counter, and pump fail counter. Program Push Button (with display board only) when pressed puts panel in program mode.

G

STOP

G H K

I J

Model Shown IFS81W114X912A8AC (Inner door view)

1 3 10 7 11 4 8 5 6 9 2 12

K.

Note: LED display will turn off after one minute of not being used.

Model Shown IFS81W114X912A8AC (Inside view)

Reg. Cdn Pat. & TM Off

PANEL COMPONENTS

1. Enclosure measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Red Alarm Beacon provides 360° visual check of alarm condition. IEC Motor Contactors control pump by switching electrical lines. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Float Connection Terminal Block Large Incoming Power and Pump Connection Terminal Block Terminal Block Installation Label Ground Lugs

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

2. 3. 4.

5. 6. 7. 8. 9.

10. Alarm Activation Relay 11. Capacitor Start Modules - start/run capacitor kits must be ordered separately. 12. Circuit Breakers (optional) provide pump disconnect and branch circuit protection. NOTE: Schematic/Wiring Diagram and Pump Specification Label are located inside the panel on enclosure cover PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

13

CONTROL PANELS

IFS8

ALARM PACKAGE

W

1

MODEL IFS8 .......................................................................................................................................... $1470.00

1 = alarm package (includes test/normal/silence switch, fuse, red light, horn) .............................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

STARTING DEVICE

1 = IEC motor contactor 120/208/240V .......................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA ......................................................................................................................................... $105.00 = 20-30 FLA ......................................................................................................................................... $125.00 = 30-40 FLA ......................................................................................................................................... $150.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker ................................................................................................................................. $140.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats ............................................................................................................................................... -$75.00

OPTIONS Listed below

Start/run capacitor kits must be ordered separately (see option 12 below or call factory). ............................................ Total Options

........................................................................................................................................................................ ENCLOSURE UPSIZE - If one or more of the options are selected,

________ ________ ________

add a one-time $130.00 list enclosure upsize ................................................................................................................................. TOTAL LIST PRICE

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

Enclosure Upsize

CODE DESCRIPTION

LIST PRICE

CODE

DESCRIPTION

LIST PRICE

3A Alarm flasher ................................................. $50.00 5A Thermal cutout/heat sensor auto reset ........ $80.00 (for pumps with thermal switch leads) 5 E Seal fail circuit and indicator ....................... $315.00 6A Auxiliary alarm contact, form C .................... $40.00 8AC Display board includes: ETM counter, events (cycles) counter, alarm counter. ................ $100.00 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-30 FLA ...................................................... $120.00 30-40 FLA .................................................... $200.00 10E Lockable latch ................................................ $40.00 10F Lightning arrester ........................................ $160.00 10K Anti-condensation heater ........................... $100.00 11C NEMA 1 alarm panel ...................................... $65.00 (must select option 6A)

11D NEMA 4X alarm panel (must select option 6A) ............ $170.00 12B Customer supplied motor start components, mounted in enclosure by SJE-Rhombus .......................................... $110.00 12C Motor start component, mounted and supplied by SJE-Rhombus ........................................................... Call Factory 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ................. $5.00 17D Sensor Float® / externally weighted (per float) ............... $7.00 17G SJE MilliAmpMasterTM / pipe clamp (per float) .................... $0.00 17H SJE MilliAmpMasterTM / externally weighted (per float) ... $7.00 19F Fourth float to separate alarm from lag .......................... $25.00

SAMPLE

MODEL IFS8 1 W 1 1 4 H 912A 12B

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Pump Overload, Motor Start Components Supplied by Customer

LIST PRICE IFS8 ...... $1470.00 1 ............. Base W ............. Base 1 ............. Base 1 ............. Base 4 ........ $140.00 H ............. Base 912A ........ $120.00 12B ........ $110.00 TOTAL LIST PRICE $1840.00

14

Cat Page PN 1019701C © SJE-Rhombus Controls Printed in USA 11/07

CONTROL PANELS

MODEL 111 Control Panel

Single phase, simplex motor contactor or pump switch control. The Model 111 control panel provides a reliable means of controlling one 120, 208, or 240 VAC single phase pump in water and wastewater installations. The motor contactor version utilizes two control switches that activate a magnetic motor contactor to turn the pump on and off. A pump float switch can also be utilized as the pump starting device. Common applications include pump chambers, sump pump basins, irrigation systems, and lift stations.

PANEL COMPONENTS

1. Enclosure measures 6 x 6 x 4 inches (15.24 x 15.24 x 10.16 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). HOA Switch for manual pump control. Green Pump Run Indicator Light Terminal Block Ground Lug Magnetic Motor Contactor controls pump by switching electrical lines. (* models only) Control Fuse

5 6 1 3 2 7 4

2. 3. 4. 5. 6. 7.

Model Shown 1110W910X Motor Contactor Control

PRICING/ORDERING INFORMATION

Model Number 1110W900H* 1110W910H* 1110W920H* VAC 120V 120V 120V FLA 0-7 7-15 15-20 NEMA RTG 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 1 1 1 1 1 1 1 1 1 1 1 Pump and Control Switch Information Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches 20' SJE PumpMaster® Plus pump switch 20' 120 VAC Double Float® pump switch 20' 240 VAC Double Float® pump switch 20' Super Single® pump switch No pump switch Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches Two 20' Sensor Float® control switches 20' SJE PumpMaster® Plus pump switch 20' 120 VAC Double Float® pump switch 20' 240 VAC Double Float® pump switch 20' Super Single® pump switch No pump switch List Price $295.00 $295.00 $295.00 $300.00 $300.00 $300.00 $245.00 $275.00 $275.00 $255.00 $210.00 $255.00 $255.00 $255.00 $260.00 $260.00 $260.00 $205.00 $235.00 $235.00 $215.00 $170.00 Shipping Weight 5 lbs. 5 lbs. 5 lbs. 5 5 lbs. 5 lbs. 5 lbs. 5 lbs. 5 lbs. 5 lbs. 5 lbs. 5 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 4 2 1 3

1110W100H* 120/208/240V 0-7 1110W110H* 120/208/240V 7-15 1110W120H* 120/208/240V 15-20 1110W200H 120/208/240V 0-15 1110W300H 1110W400H 1110W500H 120V 208/240V 0-15 0-12

Model Shown 1110W600X Pump Switch Control

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes float switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

120V 0-15 208/240V 0-12 1110W600X 120/208/240V 0-15 1110I900H* 1110I910H* 1110I920H* 120V 120V 120V 0-7 7-15 15-20

1110I100H* 120/208/240V 0-7 1110I110H* 120/208/240V 7-15 1110I120H* 120/208/240V 15-20 1110I200H 120/208/240V 0-15 1110I300H 1110I400H 1110I500H 120V 208/240V 0-15 0-12

120V 0-15 208/240V 0-12 1110I600X 120/208/240V 0-15

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

15

CONTROL PANELS

111

0

0

MODEL 111 ............................................................................................................................................... $295.00

ALARM PACKAGE

0 = select options or no alarm package .......................................................................................................... Base

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ..................................................................................................................... - $40.00 W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base ________

STARTING DEVICE

1 2 3 4 5 6 9 = magnetic motor contactor 120/208/240V ............................................................................................... $ 5.00 = SJE PumpMaster® Plus pump switch (0-15 FLA) ............................................................................... - $50.00 = 120 VAC Double Float® pump switch (0-15 FLA) ............................................................................... - $20.00 = 240 VAC Double Float® pump switch (0-12 FLA) ............................................................................... - $20.00 = Super Single® pump switch (120V = 0-15 FLA) (208/240V = 0-12 FLA) ............................................ - $40.00 = no pump switch ................................................................................................................................ - $85.00 = magnetic motor contactor 120V only ....................................................................................................... Base

________

PUMP FULL LOAD AMPS

0 = 0-7 FLA .................................................................................................................................................. Base 1 = 7-15 FLA ................................................................................................................................................ Base 2 = 15-20 FLA (for magnetic motor contactor only - select options "1" or "9" under "starting device") ......... Base

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats with motor contactor (starting device options "1" or "9") ..................................................... - $ 50.00 X = no floats (starting device option "6") ......................................................................................................... Base ________

OPTIONS Listed below

Total Options ................................................................................................................................. TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

Options 17A, 17B, 17C, 17D, 17E, & 17F may only be selected if a contactor is chosen as the starting device.

CODE DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

10E Lockable latch - NEMA 4X ................................. $20.00 10E Lockable latch - NEMA 1 .................................... $30.00 16A 10' cord in lieu of 20' (per float) ....................... - $2.00 (Does not apply for Double Float® pump switch) 16B 15' cord in lieu of 20' (per float) ...................... - $1.00 16C 30' cord in lieu of 20' (per float) .......................... $5.00 16D 40' cord in lieu of 20' (per float) ........................ $15.00

17A SJE SignalMaster® / mounting strap O (per float) ............ - $2.00 17B SJE SignalMaster® / externally weighted O (per float) ....... $5.00 17C Sensor Float® / internally weighted (per float) ................ $5.00 17D Sensor Float® / externally weighted (per float) ............... $7.00 17E Sensor Float® Mini / pipe clamp (per float) ..................... - $2.00 17F Sensor Float® Mini / externally weighted (per float) ....... $5.00 19X Door mounted pump run indicator ....................................... $30.00 Mechanically-activated Mercury-activated

SAMPLE

MODEL 111 0 I 9 1 0 H 10E

LIST PRICE Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Lockable Latch 111 ........ $295.00 0 ............. Base I ......... - $40.00 9 ............. Base 1 ............. Base 0 ............. Base H ............. Base 10E ......... $ 30.00 TOTAL LIST PRICE $285.00

Cat Page PN 1011947J © SJE-Rhombus Printed in USA 11/07

16

CONTROL PANELS

MODEL 115 Control Panel

Single phase, simplex pump switch control. The Model 115 control panel provides customers with a reliable means of controlling one 120, 208, or 240 VAC single phase pump in water and wastewater installations. A pump float switch turns the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems, and lift stations.

PANEL COMPONENTS

1. Enclosure measures 8 x 6 x 4 inches (20.32 X 15.24 X 10.16 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). HOA Switch for manual pump control. Green Pump Run Indicator Light Pump Circuit Terminal Block Alarm Circuit Terminal Block (mounted on circuit board). Alarm Fuse (mounted on circuit board). Alarm Power Indicator (mounted on circuit board). Ground Lug Red Alarm Beacon provides 360° visual check of alarm condition Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon.

3 2 4 5 10 11 12 6 9 1 7

2. 3. 4. 5. 6. 7. 8. 9.

STANDARD ALARM PACKAGE

10. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating) Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of a horn. 11. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 12. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

8

Model Shown 1151W600X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards

List Ship Price Weight

$426.00 $414.00 $466.00 $466.00 $361.00 $376.00 $364.00 $416.00 $416.00 $311.00 5 lbs 5 lbs. 5 lbs. 5 lbs. 5 lbs. 10 lbs. 10 lbs. 10 lbs. 10 lbs. 10 lbs.

PRICING/ORDERING INFORMATION

Model Number

1151W500H

VAC

FLA

0-15 0-12 0-15 0-15

NEMA RTG

4X 4X 4X 4X 4X 1 1 1 1 1

Pump and Control Switch

20' Super Single® 20' Sensor Float® 20' SJE PumpMaster® Plus 20' SJE SignalMaster® 20' 120 VAC Double Float® 20' Sensor Float® 20' 240 VAC Double Float® 20' Sensor Float® None 20' Super Single® 20' Sensor Float® 20' SJE PumpMaster® Plus 20' SJE SignalMaster® 20' 120 VAC Double Float® 20' Sensor Float® 20' 240 VAC Double Float® 20' Sensor Float® None

Q Dual safety certification for the United States and Canada Q Standard package includes float switches Q Complete, step-by-step installation instructions Q Three-year limited warranty

120V 208/240V 1151W200H17A 120/208/ 240V 1151W300H 120V 1151W400H 1151W600X

208/240V 0-12 0-15 0-15 0-12 0-15 0-15

120/208/ 240V 1151I500H 120V 208/240V 1151I200H17A 120/208/ 240V 1151I300H 120V 1151I400H 1151I600X

208/240V 0-12 120/208/ 0-15 240V

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

17

CONTROL PANELS

115 MODEL 115 .......................................................................................................................................................... $426.00

ALARM PACKAGE

0 = select options or no alarm package ................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) ................................ Base ________

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ..................................................................................................................... - $50.00 W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................. Base ________

STARTING DEVICE

2 3 4 5 6 = SJE PumpMaster® Plus pump switch (0-15 FLA) ............................................................................... - $10.00 = 120 VAC Double Float® pump switch (0-15 FLA) ................................................................................ $40.00 = 240 VAC Double Float® pump switch (0-12 FLA) ................................................................................ $40.00 = Super Single® pump switch (120V = 0-15 FLA) (208/240V = 0-12 FLA) ................................................ Base = No pump switch ................................................................................................................................ - $40.00

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................. Base 1 = 7-15 FLA ............................................................................................................................................... Base

PUMP DISCONNECTS

0 = no pump disconnect .............................................................................................................................. Base 4 = circuit breaker ..................................................................................................................................... $70.00

FLOAT SWITCH APPLICATION

H or L= pump down or pump up ..................................................................................................................... Base X = no floats ........................................................................................................................................... - $25.00 ________

OPTIONS Listed below

Total Options TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

CODE

DESCRIPTION

LIST PRICE

1A Red beacon only / no audio ............................... $15.00 (must select 1E if floats included) 1C Horn only / no visual .......................................... $15.00 (must select 1E if floats included) 1E Alarm float .......................................................... $25.00 3A Alarm flasher ...................................................... $45.00 3B Manual alarm reset ............................................. $90.00 6A Auxiliary alarm contact, form C ......................... $15.00 8A Elapsed time meter (120V) ................................ $85.00 8B Elapsed time meter (240V) .............................. $140.00 10E Lockable latch - NEMA 4X ................................. $20.00 10E Lockable latch - NEMA 1 .................................... $30.00

11C NEMA 1 alarm panel (must select option 6A) ................ $65.00 11D NEMA 4X alarm panel (must select option 6A) ........... $170.00 16A 10' cord in lieu of 20' (per float) .................................... - $2.00 (Does not apply for Double Float® pump switch) 16B 15' cord in lieu of 20' (per float) ................................... - $1.00 16C 30' cord in lieu of 20' (per float) .................................... $5.00 16D 40' cord in lieu of 20' (per float) .................................... $15.00 17A SJE SignalMaster® / pipe clamp (alarm float only) .......... - $2.00 17E Sensor Float® Mini / pipe clamp (alarm float only) ........ - $2.00 19U HOA (Hand/Off Automatic) switch and pump run light through door mounted ................................................................... $60.00 19X Door mounted pump run indicator ................................... $30.00

Mechanically-activated

Mercury-activated

SAMPLE

MODEL 115 1 W 6 0 0 X 8A

LIST PRICE Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Elapsed time meter 115 ........ $426.00 1 ............. Base W ............. Base 6 ........ - $40.00 0 ............. Base 0 ............. Base X ......... -$25.00 8A .......... $85.00 $ 446.00

TOTAL LIST PRICE

18

Cat Page PN 1011948J © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 112 Control Panel

Single phase, simplex motor contactor control. The Model 112 control panel provides a reliable means of controlling one 120, 208, or 240 VAC single phase pump in pump chambers, sump pump basins, irrigation systems and lift stations. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system.

9 2 6 10 7 4 3 13

12 1 5 11 8

PANEL COMPONENTS

1. Enclosure measures 8 x 8 x 4 inches (20.32 X 20.32 X 10.16 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). * Options selected may increase enclosure size and change component layout. 2. 3. 4. 5. 6. 7. 8. 9. Magnetic Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control (mounted on circuit board). Green Pump Run Indicator Light (mounted on circuit board). Float Switch Terminal Block (mounted on circuit board). Alarm and Control Fuses (mounted on circuit board). Alarm and Control Power Indicators (mounted on circuit board). Ground Lug Circuit Breaker (optional) provides pump disconnect and branch circuit protection.

Model Shown 1121W914X

STANDARD ALARM PACKAGE

10. Red Alarm Beacon provides 360° visual check of alarm condition. Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon. 11. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 12. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition has been cleared. 13. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number

1121W900H 1121W910H 1121W920H 1121W904H 1121W914H 1121W924H 1121W100H 1121W110H 1121W120H 1121W104H 1121W114H 1121W124H 1121I900H 1121I910H 1121I920H 1121I904H 1121I914H 1121I924H 1121I100H 1121I110H 1121I120H 1121I104H 1121I114H 1121I124H

VAC

120V 120V 120V 120V 120V 120V

FLA

0-7 7-15 15-20 0-7 7-15 15-20

Circuit NEMA List Breaker Rating Price

No No No Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 1 1 1 1 1 1 1 1 1 1 1 1 $511.00 $511.00 $511.00 $546.00 $546.00 $546.00 $516.00 $516.00 $516.00 $586.00 $586.00 $586.00 $461.00 $461.00 $461.00 $496.00 $496.00 $496.00 $466.00 $466.00 $466.00 $536.00 $536.00 $536.00

Ship Weight

16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 16 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

120/208/240V 0-7 120/208/240V 7-15 120/208/240V 15-20 120/208/240V 0-7 120/208/240V 7-15 120/208/240V 15-20 120V 120V 120V 120V 120V 120V 0-7 7-15 15-20 0-7 7-15 15-20

120/208/240V 0-7 120/208/240V 7-15 120/208/240V 15-20 120/208/240V 0-7 120/208/240V 7-15 120/208/240V 15-20

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

19

CONTROL PANELS

112 MODEL 112 ............................................................................................................................................... $511.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ................................... Base ________

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ..................................................................................................................... - $50.00 W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base ________

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ................................................................................................ $5.00 9 = magnetic motor contactor 120V only ....................................................................................................... Base ________

PUMP FULL LOAD AMPS

0 1 2 3 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA ......................................................................................................................................... $115.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) ....................................................... $35.00 120/208/240V (select STARTING DEVICE option 1 above) ......................................... $70.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................ - $75.00 WITHOUT alarm package ..................................................................................................................... - $50.00

________

OPTIONS Listed below

+

ENCLOSURE UPSIZE - If you selected 3 or more of the options, or one option , add a one-time $50.00 list enclosure upsize

Total Options Enclosure Upsize TOTAL LIST PRICE

________ ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION

LIST PRICE

1A Red beacon only / no audio .............................. $15.00 (must select 1E if floats included) 1C Horn only / no visual ........................................... $15.00 (must select 1E if floats included) 1E Alarm float ........................................................... $25.00 3A Alarm flasher ........................................................ $45.00 3B Manual alarm reset ............................................. $90.00 4A Low level cutout .................................................. $55.00 (select option 4D if floats included) 4B Red low-level indicator & alarm ........................ $60.00 (must select 4A also) 4D Low-level float ..................................................... $25.00 5A Thermal cutout/heat sensor auto ....................... $40.00 reset (for pumps w/thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) ..... $280.00 6A Auxiliary alarm contact, form C ......................... $15.00 8A Elapsed time meter ............................................. $75.00 8C Event (cycle) counter .......................................... $65.00 9_A ................................................................ Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-25 FLA ........................................................... $245.00 25-30 FLA ......................................................... $310.00 10E Lockable latch - NEMA 4X ................................. $20.00 10E Lockable latch - NEMA 1 .................................... $30.00 10F Lightning arrester .............................................. $160.00 10K Anti-condensation heater ................................. $100.00

SAMPLE

MODEL 112 1 W 9 1 4

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Flasher, Elapsed Time Meter

11C NEMA 1 alarm panel must select option 6A ..................... $65.00 11D NEMA 4X alarm panel must select option 6A ................ $170.00 14B Main disconnect (rotary style, mounted through door) non-fused 0-20 FLA ............................................................................. $400.00 20-30 FLA ........................................................................... $430.00 15A Control / alarm circuit breaker ............................................ $85.00 Does not include the circuit board as in standard. 16A 10' cord in lieu of 20' (per float) ......................................... - $2.00 16B 15' cord in lieu of 20' (per float) ........................................ - $1.00 16C 30' cord in lieu of 20' (per float) ........................................... $5.00 16D 40' cord in lieu of 20' (per float) ......................................... $15.00 17A SJE SignalMaster® / mounting strap (per float) ........... - $2.00 17B SJE SignalMaster® / externally weighted (per float) ...... $5.00 17C Sensor Float ® / internally weighted (per float) ................ $5.00 17D Sensor Float® / externally weighted (per float) ............... $7.00 17E Sensor Float® Mini / pipe clamp (per float) ................... - $2.00 17F Sensor Float ® Mini / externally weighted (per float) ..... $5.00 19T TOA (Test/Off/Automatic) switch and pump run light through door mounted ....................................................................... $75.00 19U HOA (Hand/Off/Automatic) switch and pump run light through door mounted ....................................................................... $60.00 19X Door mounted pump run indicator ..................................... $30.00 21A SJE PumpMaster® in lieu of on/off switches ............... - $10.00 21B SJE PumpMaster® Plus in lieu of on/off switches ......... $16.00 21C Super Single® in lieu of on/off switches ........................ $16.00 21D Double Float® in lieu of on/off switches ........................ $30.00 Mechanically-activated Mercury-activated

LIST PRICE

H

3A 8A

112 ........ $511.00 1 ............. Base W ............. Base 9 ............. Base 1 ............. Base 4 .......... $35.00 H ............. Base 3A .......... $45.00 8A .......... $75.00 $666.00

TOTAL LIST PRICE

20

Cat Page PN 1019119D © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 122 Control Panel

Single phase, duplex alternating pump control with override. The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems and lift stations.

3 1 5 4 8 2

panel cover

14 10

9 11 6

PANEL COMPONENTS

1. Enclosure measures 10 X 10 X 6 inches (25.4 X 25.4 X 15.24 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options selected may increase enclosure size and change component layout. Magnetic Motor Contactors control pumps by switching electrical lines. HOA Switches for manual pump control (mounted on circuit board). Control Circuit Board provides pump control and alternation. Green pump Run Indicator Lights (mounted on circuit board). Circuit Breakers (optional) provide pump disconnect and branch circuit protection. Ground Lugs Float Status Indicator Lights (mounted on circuit board). Control and Alarm Power Indicator Lights (mounted on circuit board)

7

13 12

2. 3. 4. 5. 6. 7. 8. 9.

7

Model Shown 1221W114X6A

STANDARD ALARM PACKAGE

11. Red Alarm Beacon provides 360° visual check of alarm condition. Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon. 12. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 13. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 14. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

10. Auxiliary Alarm Contact, form C (mounted on circuit board). NOTE: Schematic is located inside the panel on enclosure cover.

PRICING/ORDERING INFORMATION

Model Number

1221W900H6A 1221W910H6A 1221W920H6A 1221W904H6A 1221W914H6A 1221W924H6A 1221W100H6A 1221W110H6A 1221W120H6A 1221W104H6A 1221W114H6A 1221W124H6A 1221I900H6A 1221I910H6A 1221I920H6A 1221I904H6A 1221I914H6A 1221I924H6A 1221I100H6A 1221I110H6A 1221I120H6A 1221I104H6A 1221I114H6A 1221I124H6A

VAC

120V 120V 120V 120V 120V 120V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120V 120V 120V 120V 120V 120V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120/208/240V

Circuit NEMA FLA Breaker Rating

0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 0-7 7-15 15-20 No No No Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 4X 1 1 1 1 1 1 1 1 1 1 1 1

List Price

$788.00 $788.00 $788.00 $858.00 $858.00 $858.00 $788.00 $788.00 $788.00 $928.00 $928.00 $928.00 $713.00 $713.00 $713.00 $783.00 $783.00 $783.00 $713.00 $713.00 $713.00 $853.00 $853.00 $853.00

Shipping Weight

20 20 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 25 25 25 25 25 25 lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs. lbs.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

21

CONTROL PANELS

122

ALARM PACKAGE

6A

MODEL 122 .............................................................................................................................................. $788.00

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ........................................... Base ________

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ..................................................................................................................... - $75.00 W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base ________

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ................................................................................................. Base 9 = magnetic motor contactor 120V only ....................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA ........................................................................................................................................... $10.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) ....................................................... $70.00 120/208/240V (select STARTING DEVICE option 1 above) ........................................ $140.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats ............................................................................................................................................. - $75.00 ________

OPTIONS Listed below

+

ENCLOSURE UPSIZE If you selected one or more of the + options, or two ++ options, add a one-time $65.00 for NEMA 4X, $100 for NEMA 1 list enclosure upsize

Total Options

________ ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

V

Enclosure Upsize TOTAL LIST PRICE

1A Red beacon only / no audio .............................. $20.00 (must select "0" for alarm package) 1C Horn only / no visual ........................................... $20.00 (must select "0" for alarm package) ++ 3A Alarm flasher ....................................................... $35.00 + 3B Manual alarm reset ........................................... $135.00 + 4A Low level cutout .................................................. $40.00 (select Option 4D if floats included) 4B Red low-level indicator & alarm ........................ $60.00 (must select Option 4A also) 4D Redundant off float switch ................................. $25.00 + 5A Thermal cutout/heat sensor auto reset ............. $80.00 (for pumps w/thermal switch leads) + 5E Seal failure circuit & red indicator (2 wire) .... $395.00 6A Auxiliary alarm contact, form C (included as standard) .......................................... $0.00 + 8A Elapsed time meter .......................................... $110.00 + 8C Event (cycle) counter .......................................... $90.00 + 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. + 0-25 FLA ............................................................ $370.00 + 25-30 FLA .......................................................... $500.00 10E Lockable latch - NEMA 4X ................................. $30.00 10E Lockable latch - NEMA 1 .................................... $30.00

SAMPLE

MODEL 122 1 W 9 0

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Auxiliary alarm contact, form C, Elapsed time meter, event (cycle) counter,

10F Lightning arrestor ............................................................. $160.00 (must select circuit breaker) ++ 10K Anti-condensation heater ................................................ $100.00 11C NEMA 1 alarm panel ......................................................... $65.00 11D NEMA 4X alarm panel .................................................... $170.00 + 14B Main disconnect (rotary style, mounted through door, non-fused) (must select circuit breaker) + 0-20 FLA (total of both pumps) ....................................... $320.00 + 20-60 FLA (total of both pumps) ..................................... $360.00 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 16B 15' cord in lieu of 20' (per float) .................................... - $1.00 16C 30' cord in lieu of 20' (per float) ..................................... $5.00 16D 40' cord in lieu of 20' (per float) ..................................... $15.00 17A SJE SignalMaster® / pipe clamp (per float) ................. - $2.00 17B SJE SignalMaster ® / externally weighted (per float) ...... $5.00 17C Sensor Float® / internally weighted V (per float) ............. $5.00 17D Sensor Float ® / externally weighted V (per float) ............. $7.00 17E Sensor Float ® Mini / pipe clamp V (per float) ............. - $2.00 17F Sensor Float® Mini / externally weighted V (per float) .... $5.00 19B Lead lag selector switch .................................................... $15.00 19F Fourth float to separate alarm function from lag ............ $25.00 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted ..................................................... $160.00 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted ..................................................... $150.00 19X Door mounted pump run indicator ................................... $40.00 Mechanically-activated V Mercury-activated

+

4

H

6A 8AC

LIST PRICE

122 ........ $788.00 1 ............. Base W ............. Base 9 ............. Base 0 ............. Base 4 .......... $70.00 H ............. Base 6A ............ $0.00 8A ........ $110.00 8C .......... $90.00 Enclosure upsize .......... $65.00 $1123.00

TOTAL LIST PRICE

22

Cat Page PN 1017379E © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 312 Control Panel

Three phase, simplex motor contactor control. The Model 312 control panel provides industrial and commerical customers with a reliable means of controlling one three phase pump in water and sewage installations. Two control switches activate a IEC motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, irrigation systems, and lift stations.

PANEL COMPONENTS

1. Enclosure measures 12 x 10 x 6 inches (30.48 x 25.40 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). IEC Motor Contactor controls pump by switching electrical lines. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/ alarm voltage. Motor Protective Switch provides adjustable overload, branch circuit protection and pump disconnect. HOA Switch for manual pump control (mounted on circuit board). Green Pump Run Indicator Light mounted on circuit board. Alarm Fuse (mounted on circuit board). Control Fuse (mounted on circuit board). Alarm and Control Power Indicators (mounted on circuit board).

3 13 11 1

2. 3. 4. 5. 6. 7. 8. 9.

16

15 5 6 9 8 7 9 14 10 12

4

2

10. Float Switch Terminal Block (mounted on circuit board). 11. Input Power Terminal Block 12. Ground Lugs NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

Model Shown 3121W511X

STANDARD ALARM PACKAGE

13. Red Alarm Beacon provides 360° visual check of alarm condition. 14. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 15. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 16. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PRICING/ORDERING INFORMATION

Model Number

3121W001H 3121W101H 3121W201H 3121W301H 3121W401H 3121W511H 3121W611H 3121W621H 3121W701H

AC Voltage

208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC

FLA

1.0-1.6 1.6-2.5 2.5-4.0 4.0-6.3 6.0-10.0 9.0-14.0 13.0-18.0 17.0-23.0 20.0-25.0

List Price

$1136.00 $1136.00 $1136.00 $1136.00 $1136.00 $1181.00 $1181.00 $1191.00 $1191.00

Shipping Weight

23 lbs. 23 lbs. 23 lbs. 23 lbs. 23 lbs. 23 lbs. 23 lbs. 23 lbs. 23 lbs.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

23

CONTROL PANELS

312

W

MODEL 312 ............................................................................................................................................ $1136.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) .................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $45.00 13.0-18.0 FLA ................................................................................................................................... $45.00 17.0-23.0 FLA ................................................................................................................................... $55.00 20.0-25.0 FLA ................................................................................................................................... $55.00

________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................ - $75.00 WITHOUT alarm package ..................................................................................................................... - $50.00

________

OPTIONS Listed below

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION

Total Options TOTAL LIST PRICE

________ ________

LIST PRICE

1A Red beacon only / no audio .......................... $15.00 (must select 1E if floats included) 1C Horn only / no visual ...................................... $15.00 (must select 1E if floats included) 1E Alarm float ...................................................... $25.00 3A Alarm flasher ................................................. $45.00 3B Manual alarm reset ........................................ $90.00 4A Low level cutout ............................................ $55.00 (select option 4D if floats included) 4B Red low-level indicator & alarm .................... $60.00 activation (must select 4A also) 4D Low-level float ............................................... $25.00 5A Thermal cutout/heat sensor auto .................. $40.00 reset (for pumps w/thermal switch leads) 5 E Seal failure circuit & red indicator .............. $160.00 (2 wire) 6A Auxiliary alarm contact, form C .................... $15.00 8A Elapsed time meter ........................................ $75.00 8C Event (cycle) counter .................................... $65.00 *10A Clear inner swing-out door w/dead front .. $170.00 (lights and switches mounted on inner door) *Panels ordered with this option cannot be returned. 10E Lockable latch - NEMA 4X ............................ $30.00 10G Lightning arrester ........................................ $150.00

10K 11C 11D 14B 16A 16B 16C 16D 17A 17B 17C 17D 17E 17F 19T 19U 19X 21A 21B 21C 21D

Anti-condensation heater .............................................. $125.00 NEMA 1 alarm panel must select option 6A ................... $65.00 NEMA 4X alarm panel must select option 6A .............. $170.00 Main Disconnect (14X12 enclosure upgrade) ............. $290.00 (rotary style, mounted through door) non-fused 10' cord in lieu of 20' (per float) ...................................... - $2.00 15' cord in lieu of 20' (per float) ..................................... - $1.00 30' cord in lieu of 20' (per float) ........................................ $5.00 40' cord in lieu of 20' (per float) ...................................... $15.00 SJE SignalMaster® / mounting strap (per float) ......... - $2.00 SJE SignalMaster® / externally weighted (per float) ... $5.00 Sensor Float® / internally weighted (per float) ............ $5.00 Sensor Float® / externally weighted (per float) ........... $7.00 Sensor Float® Mini / pipe clamp (per float) ................. - $2.00 Sensor Float® Mini / externally weighted (per float) ... $5.00 TOA (Test/Off/Automatic) switch and pump run light through . door mounted ................................................................... $75.00 HOA (Hand/Off/Automatic) switch and pump run light through door mounted ................................................................... $60.00 Door mounted pump run indicator ................................... $30.00 SJE PumpMaster® in lieu of on/off switches ............ - $10.00 SJE PumpMaster® Plus in lieu of on/off switches ...... $16.00 Super Single® in lieu of on/off switches .................... $16.00 Double Float® in lieu of on/off switches ..................... $30.00 Mechanically-activated Mercury-activated

SAMPLE

MODEL 312 1 W 401 H 3A 8A

LIST PRICE Alarm Package Enclosure Rating Pump Full Load Amps Float Switch Application Options: Flasher, Elapsed Time Meter 312 ...... $1136.00 1 ............. Base W ............. Base 401 ............. Base H ............. Base 3A .......... $45.00 8A .......... $75.00

TOTAL LIST PRICE $1256.00

24

Cat Page PN 1012506H © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 322 Control Panel

Three phase, duplex alternating pump control with override. The Model 322 control panel is designed to alternately control two three phase pumps in industrial and commercial water and sewage systems. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, the alarm switch activates the audio/visual alarm system. Common applications include lift stations, pump chambers, and irrigation systems.

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). IEC Motor Contactors control pumps by switching electrical lines. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control voltage. Motor Protective Switches provide adjustable overload, branch circuit protection and pump disconnect. Alternating Circuit Board provides pump control and alternation (U.S. Patent # 5,909,532). Green Pump Run Indicator Lights (mounted on circuit board). Alarm/Control Fuse (mounted on circuit board). Float Status Indicator Lights (mounted on circuit board). Float Switch Terminal Block (mounted on circuit board).

15 6 9 11 17 5 3 14 10 1

2. 3. 4. 5. 6. 7. 8. 9.

8 7 16 13 12

4

2

10. Input Power Terminal Block 11. Ground Lugs 12. HOA Switches for manual pump control (mounted on circuit board). 13. Control ON/OFF Switch (mounted on circuit board). NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

Model Shown 3221W511X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/ or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

STANDARD ALARM PACKAGE

14. Red Alarm Beacon provides 360° visual check of alarm condition. 15. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 16. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 17. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number

3221W001H 3221W101H 3221W201H 3221W301H 3221W401H 3221W511H 3221W611H 3221W621H 3221W701H

AC Voltage

208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC

FLA

1.0-1.6 1.6-2.5 2.5-4.0 4.0-6.3 6.0-10.0 9.0-14.0 13.0-18.0 17.0-23.0 20.0-25.0

List Price

$1613.00 $1613.00 $1613.00 $1613.00 $1613.00 $1673.00 $1673.00 $1693.00 $1693.00

Shipping Weight

26 lbs. 26 lbs. 26 lbs. 26 lbs. 26 lbs. 26 lbs. 26 lbs. 26 lbs. 26 lbs. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

25

CONTROL PANELS

322

W

MODEL 322 ............................................................................................................................................ $1613.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ........................................... Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $60.00 13.0-18.0 FLA ................................................................................................................................... $60.00 17.0-23.0 FLA ................................................................................................................................... $80.00 20.0-25.0 FLA ................................................................................................................................... $80.00

________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats .............................................................................................................................................. - $75.00 ________

OPTIONS Listed below

ENCLOSURE UPSIZE - If you selected one or more of the options, add a one-time $50.00 list enclosure upsize

Total Options Enclosure Upsize TOTAL LIST PRICE

________ ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

1A 1C 3A 3B 4A 4B 4D 5A 5E 6A 8A 8C *10A

10E 10G 10K 11C

Red beacon only / no audio .......................... $20.00 Horn only / no visual ...................................... $20.00 Alarm flasher ................................................. $35.00 Manual alarm reset ........................................ $90.00 Low level cutout ............................................ $40.00 (select option 4D if floats included) Red low-level indicator & alarm .................... $60.00 (must select 4A also) Redundant off float switch ........................... $25.00 Thermal cutout/heat sensor auto .................. $80.00 reset (for pumps w/thermal switch leads) Seal failure circuit & red indicator .............. $315.00 (2 wire) Auxiliary alarm contact, form C .................... $15.00 Elapsed time meter ...................................... $110.00 Event (cycle) counter .................................... $90.00 Clear inner swing-out door w/dead ........... $190.00 front (lights and switches mounted on inner door) *Panels ordered with this option cannot be returned. Lockable latch ................................................ $30.00 Lightning arrestor ........................................ $150.00 Anti-condensation heater ........................... $125.00 NEMA 1 alarm panel (select option 6A) ....... $65.00

11D NEMA 4X alarm panel (select option 6A) ..................... $170.00 14B Main disconnect (rotary style, mounted through door, non-fused) 0-10 FLA (total of both pumps) ..................................... $285.00 10-20 FLA (total of both pumps) ................................... $325.00 20-50 FLA (total of both pumps) ................................... $680.00 16A 10' cord in lieu of 20' (per float) ...................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17A SJE SignalMaster® / pipe clamp (per float) ................ - $2.00 17B SJE SignalMaster® / externally weighted (per float) ... $5.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17E Sensor Float® Mini / pipe clamp (per float) ................. - $2.00 17F Sensor Float® Mini / externally weighted (per float) ... $5.00 19B Lead lag selector switch ................................................. $15.00 19F Fourth float to separate alarm function from lag ........... $25.00 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted ................................................... $160.00 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted .................................................. $150.00 19X Door mounted pump run indicator ................................... $40.00 O Mechanically-activated Mercury-activated

SAMPLE

MODEL 322 1 W 401 H 8AC

Alarm Package Enclosure Rating Pump Full Load Amps Float Switch Application Options: Elapsed Time Meter, Event (cycle) Counter

322 ........ $1613.00 1 ............... Base W ............... Base 401 ............... Base H ............... Base 8A .......... $110.00 8C ............ $90.00 Enclosure Upsize ............ $50.00 TOTAL LIST PRICE $1863.00

Cat Page PN 1012507H © SJE-Rhombus Printed in USA 11/07

LIST PRICE

26

CONTROL PANELS

MODEL SGS Control Panel

Single phase, simplex sewage grinder motor contactor control. The Model SGS (sewage grinder system) control panel provides a reliable means of controlling one single phase pump. This panel, designed for water and sewage applications, controls pumps of 2 HP or less requiring external starting components.

PANEL COMPONENTS

1. Enclosure measures 12 x 10 x 6 inches (30.48 x 25.40 x 15.24 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). IEC Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control (mounted on circuit board). Green Pump Run Indicator Light (mounted on circuit board). Float Switch Terminal Block (mounted on circuit board). Alarm / Control Fuses (mounted on circuit board). Alarm and Control Power Indicators (mounted on circuit board). Pump Connection Terminal Block Ground Lug

1 2 10 11 17 18 5 3 4 7 6 16 13 14 8 9 12 15

2. 3. 4. 5. 6. 7. 8. 9.

10. Overload Relay (optional) provides pump overload protection. 11. Circuit Breaker provides pump disconnect and branch circuit protection. 12. *Run Capacitor 13. *Start Relay 14. *Start Capacitor *Start/Run components supplied for certain pump models, please call factory to verify your pump model at 1-888-DIAL-SJE (1-888-342-5753).

Model Shown SGS1W114X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty. This express warranty does not apply to motor start kit component. SJE-Rhombus makes no warranties of any type with respect to the motor start kit.

STANDARD ALARM PACKAGE

15. Red Alarm Beacon provides 360° visual check of alarm condition. NOTE: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon. 16. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). NOTE: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 17. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 18. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number Horsepower/ AC Voltage Full Load Amps

7-15 FLA

List Price

*$755.00

Shipping Weight

20 lbs.

SGS1W114H 2HP120/208/240 VAC

*Includes motor capacitor start/run components for certain pump models. Call factory at 1-800-RHOMBUS (1-800-746-6287) to verify your pump model prior to quoting. *Model SGS control panels cannot be returned. Please refer to the Product Return section on page 2. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

27

CONTROL PANELS

SGS

1

4

MODEL SGS ............................................................................................................................................ $755.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $55.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ................................... Base ________

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ....................................................................................................................... -$50.00 W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base ________

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ................................................................................................. Base

PUMP FULL LOAD AMPS

0 = 0-7 FLA .................................................................................................................................................. Base 1 = 7-15 FLA ................................................................................................................................................ Base 2 = 15-20 FLA .............................................................................................................................................. Base

PUMP DISCONNECTS

4 = circuit breaker ...................................................................................................................................... Base ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................. -$75.00

WITHOUT alarm package ......................................................................................................... -$50.00

OPTIONS Listed below

.................................................................................................................................................................................

Total Options

________ ________

...................................................................................................................................................................... TOTAL LIST PRICE

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

1A Red beacon only / no audio .................................. $10.00 (must select 1E if floats included) 1C Horn only / no visual .............................................. $15.00 (must select 1E if floats included) 1E Alarm float .............................................................. $25.00 5A Thermal cutout/heat sensor auto reset ................ $10.00 (for pumps with thermal switch leads) 5Y Seal leak indicator (two wire probe) ................... $35.00 5Z Seal leak indicator (single wire probe) ................ $30.00 6A Auxiliary alarm contact, form C ............................ $15.00 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-16 FLA ................................................................ $40.00 16-20 FLA .............................................................. $50.00 10E Lockable latch ........................................................ $30.00 11C NEMA 1 alarm panel (must select option 6A) ...... $65.00 11D NEMA 4X alarm panel (must select option 6A) . $170.00

12C Motor start components mounted and supplied by SJE-Rhombus .............................................. Call for option code 16A 10' cord in lieu of 20' (per float) ...................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17A SJE SignalMaster® / mounting strap (per float) ......... - $2.00 17B SJE SignalMaster® / externally weighted (per float) ... $5.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17E Sensor Float® Mini / pipe clamp (per float) ................. - $2.00 17F Sensor Float® Mini / externally weighted (per float) ... $5.00 19X Door mounted pump run indicator ................................... $30.00 21A SJE PumpMaster® in lieu of on/off switches ............ - $10.00 21B SJE PumpMaster® Plus in lieu of on/off switches ...... $16.00 21C Super Single® in lieu of on/off switches .................... $16.00 21D Double Float® in lieu of on/off switches ..................... $30.00 Mechanically-activated Mercury-activated

SAMPLE

MODEL SGS 0 W 1 1 4 X 1A 5A 912A 10E

LIST PRICE SGS ............ $755.00 0 ............ -$55.00 W ................. Base 1 ................. Base 1 ................. Base 4 ................. Base X ............ -$75.00 1A .............. $10.00 5A .............. $10.00 912A .............. $40.00 10E .............. $10.00 TOTAL LIST PRICE $695.00

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Beacon Only, Thermal Cutout, Pump Overload, Lockable Latch

28

Cat Page PN 1011954J © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 113 Control Panel

Single phase, simplex capacitor start/run pump control. Model 113 control panels provide a reliable means of controlling one 120, 208, or 240 VAC single phase pump requiring external starting components in water and sewage installations. Two control switches activate an IEC motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers and lift stations.

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 X 30.48 X 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). * Options selected may increase enclosure size and change component layout. 2. 3. 4. 5. 6. 7. 8. 9. IEC Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control (mounted on circuit board). Green Pump Run Indicator Light (mounted on circuit board). Float Switch Terminal Block (mounted on circuit board). Alarm and Control Fuses (mounted on circuit board). Alarm and Control Power Indicators (mounted on circuit board). Pump Input Power and Pump Connection Terminal Block Ground Lugs

1 2 10 4 7 14 3 6 15 5 9 13 8 11 12

10. Circuit Breaker (optional) provides pump disconnect and branch circuit protection. 11. Capacitor Start Module - start/run capacitor kit must be ordered separately.

Model Shown 1131W124X

STANDARD ALARM PACKAGE

12. Red Alarm Beacon provides 360° visual check of alarm condition. 13. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 14. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 15. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PRICING/ORDERING INFORMATION

Model Number

1131W110H12B 1131W114H12B 1131W134H12B 1131W144H12B

AC Voltage

120/208/240 VAC 120/208/240 VAC 120/208/240 VAC 120/208/240 VAC

FLA

7-15 7-15 20-30 30-40

List Price

$780.00 $850.00 $880.00 $900.00

Shipping Weight

20 lbs. 20 lbs. 20 lbs. 20 lbs.

*Model 113 control panels cannot be returned. Please refer to the Product Return section on page 2.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

29

CONTROL PANELS

113

W

1

MODEL 113 ............................................................................................................................................... $670.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ................................... Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

STARTING DEVICE

1 = IEC motor contactor 120/208/240V .......................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA ........................................................................................................................................... $30.00 = 30-40 FLA ........................................................................................................................................... $50.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker .................................................................................................................................. $ 70.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................ - $75.00 WITHOUT alarm package ..................................................................................................................... - $50.00

________

OPTIONS Listed below

Start/run capacitor kits must be ordered separately (see option 12 below or call factory)

Total Options

________ ________

................................................................................................................................. TOTAL LIST PRICE

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

SAMPLE

MODEL

1A Red beacon only / no audio .......................... $15.00 (must select 1E if floats included) 1C Horn only / no visual ...................................... $15.00 (must select 1E if floats included) 1E Alarm float ...................................................... $25.00 3A Alarm flasher ................................................. $45.00 3B Manual alarm reset ........................................ $90.00 4A Low level cutout ............................................ $55.00 (select option 4D if floats included) 4B Red low-level indicator & alarm .................... $60.00 (must select 4A also) 4D Low-level float ............................................... $25.00 5A Thermal cutout/heat sensor auto reset ........ $40.00 (for pumps with thermal switch leads) 5 E Seal fail circuit and indicator (2 wire) ........ $160.00 6A Auxiliary alarm contact, form C .................... $15.00 8A Elapsed time meter ........................................ $75.00 8C Event (cycle) counter .................................... $65.00 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-30 FLA ........................................................ $60.00 30-40 FLA .................................................... $100.00 10E Lockable latch ................................................ $30.00 10F Lightning arrester ........................................ $160.00 10K Anti-condensation heater ........................... $100.00 11C NEMA 1 alarm panel ...................................... $65.00 (must select option 6A)

11D NEMA 4X alarm panel must select option 6A .............. $170.00 12B Customer supplied motor start components, mounted in enclosure by SJE-Rhombus .......................................... $110.00 12C Motor start component, mounted and supplied by SJE-Rhombus ........................................................... Call Factory 14B Main disconnect (rotary style, mounted through door, non-fused) 0-20 FLA ........................................................................ $450.00 20-40 FLA ....................................................................... $480.00 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17A SJE SignalMaster® / mounting strap (per float) ......... - $2.00 17B SJE SignalMaster® / externally weighted (per float) ... $5.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17E Sensor Float® Mini / pipe clamp (per float) ................. - $2.00 17F Sensor Float® Mini / externally weighted (per float) ... $5.00 19T TOA (Test/Off/Automatic) switch and pump run light through door mounted ..................................................... $75.00 19U HOA (Hand/Off/Automatic) switch and pump run light through door mounted ..................................................... $60.00 19X Door mounted pump run indicator ................................... $30.00 21A SJE PumpMaster® in lieu of on/off switches ............ - $10.00 21B SJE PumpMaster® Plus in lieu of on/off switches ...... $16.00 21C Super Single® in lieu of on/off switches .................... $16.00 21D Double Float® in lieu of on/off switches ..................... $30.00 Mechanically-activated Mercury-activated

113

1

W

1

1

4

H

912A 12B

LIST PRICE

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Pump Overload, Motor Start Components Supplied by Customer

113 ........ $670.00 1 ............. Base W ............. Base 1 ............. Base 1 ............. Base 4 .......... $70.00 H ............. Base 912A .......... $60.00 12B ........ $110.00 $910.00

TOTAL LIST PRICE

30

Cat Page PN 1012510H © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 123 Control Panel

Single phase, duplex capacitor start/run pump control with override. Model 123 control panels are designed to alternately control two 120, 208, or 240 VAC single phase pumps requiring external starting components in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, these systems provide override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers and lift stations.

PANEL COMPONENTS

1. Enclosure measures 16 X 14 X 6 inches (40.64 X 35.56 X 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options selected may increase enclosure size and change component layout. IEC Motor Contactors control pumps by switching electrical lines. HOA Switches for manual pump control (mounted on circuit board). Alternating Circuit Board provides pump control and alternation (U.S. Patent 5,909,352). Green pump Run Indicator Lights (mounted on circuit board). Incoming Pump Power Terminal Block / Pump Terminal Block Circuit Breakers (optional) provide pump disconnect and branch circuit protection. Control ON/OFF Switch (mounted on circuit board). Ground Lugs

16 10 15 8 5 3 4 14 12 1 13 2

7

2. 3. 4. 5. 6. 7. 8. 9.

6 11 9

10. Float Status Indicator Lights (mounted on circuit board). 11. Control / Alarm Power Indicator Light (mounted on circuit board). 12. Capacitor Start Modules - start/run capacitor kits must be ordered separately. NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

Model Shown 1231W124X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/ or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

STANDARD ALARM PACKAGE

13. Red Alarm Beacon provides 360° visual check of alarm condition. 14. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 15. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 16. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number

1231W110H12B 1231W114H12B 1231W134H12B 1231W144H12B

AC Voltage

120/208/240 VAC 120/208/240 VAC 120/208/240 VAC 120/208/240 VAC

Full Load Amps

7-15 FLA 7-15 FLA 20-30 FLA 30-40 FLA

List Price

$1121.00 $1261.00 $1341.00 $1381.00

Shipping Weight

24 lbs. 24 lbs. 24 lbs. 24 lbs. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

*Model 123 control panels cannot be returned. Please refer to the Product Return section on page 2. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

31

CONTROL PANELS

123

W

1

MODEL 123 ............................................................................................................................................ $1011.00

ALARM PACKAGE

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn) .............................................. Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

STARTING DEVICE

1 = IEC motor contactor 120/208/240V .......................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA ........................................................................................................................................... $80.00 = 30-40 FLA ......................................................................................................................................... $120.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker ................................................................................................................................. $140.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats ............................................................................................................................................... -$75.00

OPTIONS Listed below

Start/run capacitor kits must be ordered separately (see option 12 below or call factory). ............................................ Total Options

________ ________ ________

........................................................................................................................................................................ ENCLOSURE UPSIZE - If one or more of the options are selected,

Enclosure Upsize

add a one-time $130.00 list enclosure upsize ................................................................................................................................. TOTAL LIST PRICE

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

1A 1C 3A 3B 4A 4B 4D 5A 5E 6A 8A 8C 9_A

10E 10F 10K 11C

Red beacon only / no audio ..................... $20.00 Horn only / no visual ................................. $20.00 Alarm flasher ............................................ $35.00 Manual alarm reset ................................... $90.00 Low level cutout ....................................... $40.00 (select option 4D if floats included) Red low-level indicator & alarm ............... $60.00 (must select 4A also) Low-level float .......................................... $25.00 Thermal cutout/heat sensor auto reset ... $80.00 (for pumps with thermal switch leads) Seal fail circuit and indicator (2 wire) .. $315.00 Auxiliary alarm contact, form C ............... $15.00 Elapsed time meter ................................ $110.00 Event (cycle) counter ............................... $90.00 Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. 0-30 FLA ................................................ $120.00 30-40 FLA .............................................. $200.00 Lockable latch ........................................... $30.00 Lightning arrester .................................. $160.00 (must select pump circuit breakers) Anti-condensation heater ..................... $100.00 NEMA 1 alarm panel ................................. $65.00 (must select option 6A)

SAMPLE

MODEL 123 1 W 1 1 4

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Thermal Cutout, Pump Overload, Motor Start Components Supplied by Customer

11D NEMA 4X alarm panel (must select option 6A) .............. $170.00 12B Customer supplied motor start components, mounted in enclosure by SJE-Rhombus $110.00 12C Motor start component, mounted and supplied by SJE-Rhombus .............................................................. Call Factory 14B Main disconnect (rotary style, mounted through door, non-fused) (must select pump circuit breakers) 0-20 FLA ....................................................................... $320.00 20-80 FLA ..................................................................... $360.00 16A 10' cord in lieu of 20' (per float) ........................................ - $2.00 16B 15' cord in lieu of 20' (per float) ....................................... - $1.00 16C 30' cord in lieu of 20' (per float) .......................................... $5.00 16D 40' cord in lieu of 20' (per float) ........................................ $15.00 17A SJE SignalMaster® / pipe clamp (per float) .................. - $2.00 17B SJE SignalMaster® / externally weighted (per float) ...... $5.00 17C Sensor Float® / internally weighted (per float) ............... $5.00 17D Sensor Float® / externally weighted (per float) .............. $7.00 17E Sensor Float® Mini / pipe clamp (per float) .................... - $2.00 17F Sensor Float® Mini / externally weighted (per float) ..... $5.00 19B Lead lag selector switch ................................................... $15.00 19F Fourth float to separate alarm from lag ............................. $25.00 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted ...................................................... $160.00 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted ...................................................... $150.00 19X Door mounted pump run indicator ...................................... $40.00 Mechanically-activated Mercury-activated LIST PRICE 123 ......... $1011.00 1 ................ Base W ................ Base 1 ................ Base 1 ................ Base 4 ........... $140.00 H ................ Base 5A ............. $80.00 912A ........... $120.00 12B ........... $110.00 Enclosure Upsize ........... $130.00 TOTAL LIST PRICE $1591.00

H

5A 912A 12B

32

Cat Page PN 1011956K © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 114 Control Panel

Single phase, simplex pump control with intrinsically safe circuits. The Model 114 control panel is designed for applications requiring intrinsically safe float circuits or other circuit extensions. This panel will control one 120, 208, or 240 VAC single phase pump. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, lift stations, or other installations classified as hazardous locations requiring intrinsically safe circuits.

PANEL COMPONENTS

7 10 8 9 6 5 15 18 1 13 11 4 14 12

1.

Enclosure measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Intrinsically Safe Module limits the amount of energy to switches preventing ignition of flammable gases. Intrinsically Safe Partition isolates the intriniscally safe wiring. IEC Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control (mounted on circuit board). Green Pump Run Indicator Light (mounted on circuit board). Alarm Fuse (mounted on circuit board). Control Fuse (mounted on circuit board). Control Power Indicator Light (mounted on circuit board).

17 16 2

2. 3. 4. 5. 6. 7. 8. 9.

3

Model Shown 1141W114X

STANDARD ALARM PACKAGE

15. Red Alarm Beacon provides 360° visual check of alarm condition. 16. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 17. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 18. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

10. Alarm Power Indicator Light (mounted on circuit board). 11. Input Power Terminal Block 12. Ground Lugs 13. Circuit Breaker (optional) provides pump disconnect and branch circuit protection. 14. Overload Relay (optional) provides thermal overload protection for pump. NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

PRICING/ORDERING INFORMATION

Model Number

1141W914H 1141W924H 1141W934H 1141W944H 1141W110H 1141W114H

FEATURES

AC Voltage

120V 120V 120V 120V 120/208/240V 120/208/240V

Circuit Full Load Breaker Amps

Yes Yes Yes Yes No Yes No Yes No Yes No Yes 7-15 15-20 20-30 30-40 7-15 7-15 15-20 15-20 20-30 20-30 30-40 30-40

List Price

$1381.00 $1381.00 $1411.00 $1431.00 $1346.00 $1416.00 $1346.00 $1416.00 $1376.00 $1446.00 $1396.00 $1466.00

Shipping Weight

24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs. 24 lbs.

Q Industrial control panel is UL Listed relating to hazardous locations with intrinsically safe circuit extenstions Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

1141W120H 120/208/240V 1141W124H 120/208/240V 1141W130H 120/208/240V 1141W134H 120/208/240V 1141W140H 120/208/240V 1141W144H 120/208/240V

Panels include three 20' Sensor Float® normally open control switches. *Model 114 control panels cannot be returned. Please refer to the Product Return section on page 2.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

33

CONTROL PANELS

114

432109876543210987654321 1 43210987654321098765432 432109876543210987654321 432109876543210987654321 432109876543210987654321

W

............................................................................................................................................................................. $1346.00 MODEL 114 ALARM PACKAGE

________ 0 = select options or no alarm package ..................................................................................................... -$35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ................................... Base

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic)

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ................................................................................................. Base 9 = magnetic motor contactor 120V only ........................................................................................................ Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = = = = = 0-7 FLA ................................................................................................................................................ Base 7-15 FLA .............................................................................................................................................. Base 15-20 FLA ............................................................................................................................................. Base 20-30 FLA .......................................................................................................................................... $30.00 30-40 FLA .......................................................................................................................................... $50.00

________

PUMP DISCONNECTS

0 = no pump disconnect ................................................................................................................................ Base 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) ...................................................... $35.00 120/208/240V (select STARTING DEVICE option 1 above) ...................................... $70.00

________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................. -$75.00 WITHOUT alarm package ...................................................................................................................... -$50.00

________

OPTIONS Listed below

................................................................................................................................................................................. Total Options If additional features are required, call the factory for a quote on an Engineered Custom control panel. ................................................................................................................................. TOTAL LIST PRICE

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION

________ ________

LIST PRICE

1A Red beacon only / no audio ............................ $15.00 (must select 1E if floats included) 1C Horn only / no visual ........................................ $15.00 (must select 1E if floats included) 1E Alarm float ........................................................ $25.00 3A Alarm flasher ................................................... $45.00 3B Manual alarm reset .......................................... $90.00 3C Red high / low indicator light ......................... $300.00 & alarm activation (4A not needed) 3D Float for low indicator ..................................... $25.00 (must select option 3C) 4A Low-level cutout ............................................. $55.00 (select option 4D if floats included, 3C not needed) 4B Red low-level indicator & alarm .................... $240.00 (must select 4A also) 4D Low-level float ................................................. $25.00 5A Thermal cutout/heat sensor auto reset .......... $40.00 (for pumps with thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) .. $160.00 5M Seal fail alarm activation ................................. $40.00 (must selection option 5E) 6A Auxiliary alarm contact, form C ...................... $15.00 6G Auxiliary contact, dry, seal fail, ...................... $40.00 normally open (must select option 5E) 8A Elapsed time meter .......................................... $75.00 8C Event (cycle) counter ...................................... $65.00 9_A Overload protection specify amperage after number 9

followed by letter "A" (Ex. 912A = 12 amp pump)

10A 10E 10F 10K 11C 11D 12B 12C 14B

16A 16B 16C 16D 17C 17D 17G 17H 19T 19U 19X

0-25 FLA .......................................................................... $60.00 25-40 FLA ...................................................................... $100.00 Clear inner swing-out door w/dead front .................... $170.00 (lights and switches mounted on inner door) Lockable latch .................................................................. $30.00 Lightning arrester .......................................................... $160.00 Anti-condensation heater .............................................. $100.00 NEMA 1 alarm panel (must select option 6A) ................ $65.00 NEMA 4X alarm panel (must select option 6A) ............ $170.00 Motor start components supplied by customer, mounted by SJE-Rhombus (18 x 16 enclosure upgrade) ........ $170.00 Motor start components mounted and supplied by SJE-Rhombus (18 x 16 enclosure upgrade) ........ Call Factory Disconnect (rotary style, mounted through door, non-fused 0-20 FLA ........................................................................ $285.00 20-40 FLA ...................................................................... $325.00 10' cord in lieu of 20' (per float) ...................................... - $2.00 15' cord in lieu of 20' (per float) ..................................... - $1.00 30' cord in lieu of 20' (per float) ........................................ $5.00 40' cord in lieu of 20' (per float) ...................................... $15.00 Sensor Float® / internally weighted (per float) ............ $5.00 Sensor Float® / externally weighted (per float) ........... $7.00 MilliAmpMasterTM/ pipe clamp (per float) ....................... $0.00 MilliAmpMasterTM/ externally weighted (per float) ........ $7.00 TOA (Test/Off/Automatic) switch and pump run light through door mounted ..................................................... $75.00 HOA (Hand/Off/Automatic) switch and pump run light through door mounted ..................................................... $60.00 Door mounted pump run indicator ................................... $30.00

Mechanically-activated

Mercury-activated 114 ....... $1346.00 1 .............. Base W .............. Base 9 .............. Base 1 .............. Base 4 ........... $35.00 H .............. Base 912A ........... $60.00

SAMPLE

MODEL 114 1 W 9 1 4 H 912A

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Pump Overloads

LIST PRICE

TOTAL LIST PRICE $1441.00

Cat Page PN 1012512H © SJE-Rhombus Printed in USA 11/07

34

CONTROL PANELS

MODEL 124 Control Panel

Single phase, duplex alternating pump control with intrinsically safe circuits. The Model 124 control panel is designed for applications requiring intrinsically safe float circuits or other circuit extensions. This panel will alternately control two 120/208/240 VAC single phase pumps. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers, lift stations, or other installations classified as hazardous locations requiring intrinsically safe circuits.

PANEL COMPONENTS

1. Enclosure measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options selected may increase enclosure size and change component layout. Intrinsically Safe Module limits the amount of energy to switches preventing ignition of flammable gasses. Intrinsically Safe Partition isolates intrinsically safe wiring. IEC Motor Contactors control pumps by switching electrical lines. HOA Switches for manual pump control (mounted on circuit board). Alternating Control Circuit Board provides pump control and alternation. (U.S. patent 5,909,352). Green Pump Run Indicator Lights (mounted on circuit board). Float Status Indicator Lights (mounted on circuit board). Input Power Terminal Block

5 7 17 4 16 2 3 9 14 10 12 11 6 15 8 18 1 13

2. 3. 4. 5. 6. 7. 8. 9.

Model Shown 1241W114X

STANDARD ALARM PACKAGE

15. Red Alarm Beacon provides 360° visual check of alarm condition. 16. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 17. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 18. Horn Silence Relay (mounted on circuit board). NOTE: other options available.

10. Ground Lugs 11. Control ON/OFF Switch (mounted on circuit board). 12. Control/Alarm Power Indicator Light (mounted on circuit board). 13. Circuit Breakers (optional) provide pump disconnect and branch circuit protection. 14. Adjustable Overloads (optional) provide thermal overload protection for pump. NOTE: Schematic/Wiring diagram is located inside the panel on enclosure cover.

PRICING/ORDERING INFORMATION

Model Number

1241W914H 1241W924H 1241W934H 1241W944H

AC Voltage

120V 120V 120V 120V

Circuit Breaker

Yes Yes Yes Yes No Yes No Yes No Yes No Yes

®

Full Load Amps

7-15 FLA 15-20 FLA 20-30 FLA 30-40 FLA 7-15 FLA 7-15 FLA 15-20 FLA 15-20 FLA 20-30 FLA 20-30 FLA 30-40 FLA 30-40 FLA

List Price

$1876.00 $1876.00 $1956.00 $1996.00 $1806.00 $1946.00 $1806.00 $1946.00 $1886.00 $2026.00 $1926.00 $2066.00

Shipping Weight

25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs.

FEATURES

Q Industrial control panel is UL Listed relating to hazardous locations with intrinsically safe circuit extensions Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

1241W110H 120/208/240V 1241W114H 120/208/240V 1241W120H 120/208/240V 1241W124H 120/208/240V 1241W130H 120/208/240V 1241W134H 120/208/240V 1241W140H 120/208/240V 1241W144H 120/208/240V

Panels include three 20' Sensor Float normally open control switches. *Model 124 control panels cannot be returned. Please refer to the Product Return section on page 2.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

35

CONTROL PANELS

124 W ooo MODEL 124 ..................................................................................................................................................... $1806.00

ALARM PACKAGE

0 = select options or no alarm package .............................................................................................................................. - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ........................................... Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base ________

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ................................................................................................. Base 9 = magnetic motor contactor 120V only ....................................................................................................... Base

PUMP FULL LOAD AMPS

0 1 2 3 4 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA .......................................................................................................................................... $ 80.00 = 30-40 FLA .......................................................................................................................................... $120.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) ...................................................... $ 70.00 120/208/240V (select STARTING DEVICE option 1 above) ........................................ $140.00 ________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats ............................................................................................................................................. - $75.00 ________

OPTIONS Listed below

................................................................................................................................................................................. ENCLOSURE UPSIZE - If one or more of the options are selected,

Total Options ................................................................................................................................... Enclosure Upsize add a one-time $150.00 list enclosure upsize ................................................................................................................................. TOTAL LIST PRICE If additional features are required, call factory for quote on an Engineered Custom control panel.

________ ________ ________

CODE

DESCRIPTION

LIST PRICE

CODE

DESCRIPTION

LIST PRICE

1A Red beacon only / no audio ............................. $20.00 (must select "0" for alarm package) 1C Horn only / no visual ........................................ $20.00 (must select "0" for alarm package) 3A Alarm flasher .................................................... $35.00 3B Manual alarm reset ........................................... $90.00 3C Red high / low indicator lights ....................... $220.00 & alarm activation (4A not needed) 3D Float for low indicator ...................................... $25.00 (must select option 3C) 4A Low level cutout .............................................. $55.00 (select Option 4D if floats included, 3C not needed) 4B Red low-level indicator & alarm ....................... $70.00 (must select Option 4A also) 4D Redundant off float switch ............................. $25.00 5A Thermal cutout/heat sensor auto reset .......... $80.00 (for pumps with thermal switch leads) 5 E Seal fail circuit and indicator (2 wire) ........... $315.00 5M Seal fail alarm activation .................................. $60.00 (must select option 5E) 6A Auxiliary alarm contact, form C ....................... $15.00 6G Auxiliary contact, seal fail, normally open (must select option 5E) ................................... $40.00 8A Elapsed time meter ......................................... $110.00 8C Event (cycle) counter ...................................... $90.00 9__A Overload protection specify amperage after number

9 followed by letter "A'' (ex. 912A = 12 amp pump)

0-25 FLA ......................................................... $120.00 25-40 FLA ....................................................... $200.00

SAMPLE

MODEL 124 1 W 9 1 4

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Pump Overloads

10A Clear inner swing-out door w/dead front ...................... $190.00 (lights and switches mounted on inner door) 10E Lockable latch .................................................................... $30.00 10F Lightning arrestor (must select circuit breaker) .......... $160.00 10K Anti-condensation heater ............................................... $100.00 11C NEMA 1 alarm panel (must select option 6A) ................ $65.00 11D NEMA 4X alarm panel (must select option 6A) ............. $170.00 12B Motor start components .................................................. $455.00 (supplied by customer, mounted by SJE-Rhombus) 12C Motor start components ............................................ Call Factory (supplied and mounted by SJE-Rhombus) 14B Main disconnect (rotary style, mounted through door, non-fused) (must select circuit breaker) 0-20 FLA (total of both pumps) ................................. $305.00 20-80 FLA (total of both pumps) ............................... $345.00 16A 10' cord in lieu of 20' (per float) ..................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ...................................... $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17G MilliAmpMasterTM/ pipe clamp (per float) ......................... $0.00 17H MilliAmpMasterTM/ externally weighted (per float) ......... $7.00 19B Lead lag selector switch ................................................. $15.00 19F Fourth float to separate alarm function from lag ........... $175.00 19G Panel wired to accept fourth control switch ................ $150.00 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted .................................................... $160.00 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted ................................................... $150.00 19X Door mounted pump run indicator .................................... $40.00 Mechanically-activated Mercury-activated

H

912A

LIST PRICE

124 ....... $1806.00 1 .............. Base W .............. Base 9 .............. Base 1 .............. Base 4 ........... $70.00 H .............. Base 912A ......... $120.00

TOTAL LIST PRICE $1996.00

Cat Page PN 1011958K © SJE-Rhombus Printed in USA 11/07

36

CONTROL PANELS

MODEL 314 Control Panel

Three phase, simplex pump control with intrinsically safe circuits. The Model 314 control panel is designed for applications requiring intrinsically safe float circuits or other circuit extensions. This panel will control one 208/240/480 VAC three phase pump. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, lift stations, or other installations classified as hazardous locations requiring intrinsically safe circuits.

PANEL COMPONENTS

10 14 8 6 15 18 1 7

1.

Enclosure measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable flanges for outdoor or indoor use). Intrinsically Safe Module limit the amount of energy to switches preventing ignition of flammable gases. Intrinsically Safe Partition isolates intrinsically safe wiring. Motor Protective Switch provides adjustable overload, branch circuit protection and pump disconnect. IEC Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control (mounted on circuit board). Multi-tap Transformer (208/240/480 VAC primary) provides 120V control/alarm voltage. Green Pump Run Indicator Light (mounted on circuit board). Alarm Fuse (mounted on circuit board).

13 9 17 16 2 3

2. 3. 4. 5. 6. 7. 8. 9.

4 11 5 12

Model Shown 3141W511X

STANDARD ALARM PACKAGE

15. Red Alarm Beacon provides 360° visual check of alarm condition. 16. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 17. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 18. Horn Silence Relay (mounted on circuit board). NOTE: (other options available)

10. Control Fuse (mounted on circuit board). 11. Input Power Terminal Block 12. Ground Lugs 13. Control Power Indicator Light (mounted on circuit board). 14. Alarm Power Indicator Light (mounted on circuit board). NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

PRICING/ORDERING INFORMATION

Model Number

3141W001H 3141W101H 3141W201H 3141W301H 3141W401H 3141W511H 3141W611H 3141W621H 3141W701H

FEATURES

Shipping Weight

25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs.

AC Voltage

208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC

Full Load Amps

1.0-1.6 1.6-2.5 2.5-4.0 4.0-6.3 6.0-10.0 9.0-14.0 13.0-18.0 17.0-23.0 20.0-25.0

®

List Price

$1965.00 $1965.00 $1965.00 $1965.00 $1965.00 $2010.00 $2010.00 $2020.00 $2020.00

Q Industrial control panel is UL Listed relating to hazardous locations with intrinsically safe circuit extensions Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

Panels include three 20' Sensor Float normally open control switches. *Model 314 control panels cannot be returned. Please refer to the Product Return section on page 2. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

37

CONTROL PANELS

314

ALARM PACKAGE

W

Model 1 MODEL 314 ....................................................................................................................................................... $1965.00

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ................................... Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $45.00 13.0-18.0 FLA ................................................................................................................................... $45.00 17.0-23.0 FLA ................................................................................................................................... $55.00 20.0-25.0 FLA ................................................................................................................................... $55.00

________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats WITH alarm package ............................................................................................................................ - $75.00 WITHOUT alarm package ..................................................................................................................... - $50.00

________

OPTIONS Listed below

.................................................................................................................................................................................

Total Options ................................................................................................................................. TOTAL LIST PRICE

________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

1A Red beacon only / no audio .................................. $15.00 (must select 1E if floats included) 1C Horn only / no visual .............................................. $15.00 (must select 1E if floats included) 1E Alarm float .............................................................. $25.00 3A Alarm flasher ......................................................... $45.00 3B Manual reset alarm ................................................ $90.00 3C Red high / low indicator light & ........................... $300.00 alarm activation (4A not needed) 3D Float for low indicator ........................................... $25.00 (must select option 3C) 3E Float for high indicator .......................................... $25.00 (not required if panel contains high alarm) 4A Low-level cutout ................................................... $55.00 (select option 4D if floats included, 3C not needed) 4B Red low-level indicator & alarm .......................... $220.00 (must select 4A also) 4D Low-level float ....................................................... $25.00 5A Thermal cutout/heat sensor auto reset ................ $40.00 (for pumps w/thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) ........ $160.00 5M Seal fail alarm activation ....................................... $60.00 (must selection option 5E) 6A Auxiliary alarm contact, form C ............................ $15.00 6G Auxiliary contact, dry, seal fail, normally open ... $40.00 (must select option 5E)

8A Elapsed time meter ........................................................... $75.00 8C Event (cycle) counter ...................................................... $65.00 10A Clear inner swing-out door w/dead front .................... $170.00 (lights and switches mounted on inner door) 10E Lockable latch .................................................................. $30.00 10G Lightning arrester .......................................................... $150.00 10K Anti-condensation heater .............................................. $100.00 11C NEMA 1 alarm panel (must select option 6A) ................ $65.00 11D NEMA 4X alarm panel (must select option 6A) ............ $170.00 14B Main disconnect (rotary style, mounted through door) non-fused 0-20 FLA ........................................................................ $285.00 20-25 FLA ...................................................................... $325.00 16A 10' cord in lieu of 20' (per float) ...................................... - $2.00 16B 15' cord in lieu of 20' (per float) ..................................... - $1.00 16C 30' cord in lieu of 20' (per float) ........................................ $5.00 16D 40' cord in lieu of 20' (per float) ...................................... $15.00 17C Sensor Float® / internally weighted (per float) ............ $5.00 17D Sensor Float® / externally weighted (per float) ........... $7.00 17G MilliAmpMasterTM/ pipe clamp (per float) ....................... $0.00 17H MilliAmpMasterTM/ externally weighted (per float) ........ $7.00 19T TOA (Test/Off/Automatic) switch and pump run light through door mounted ..................................................... $75.00 19U HOA (Hand/Off/Automatic) switch and pump run light through door mounted ..................................................... $60.00 19X Door mounted pump run indicator ................................... $30.00

Mechanically-activated

Mercury-activated

SAMPLE

MODEL 314 1 W 401 H 3A 8A

Alarm Package Enclosure Rating Pump Full Load Amps Float Switch Application Options: Flasher, Elapsed Time Meter

LIST PRICE

314 ...... $1965.00 1 ............. Base W ............. Base 401 ............. Base H ............. Base 3A .......... $45.00 8A .......... $75.00 TOTAL LIST PRICE $2085.00

38

Cat Page PN 1012508H © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 324 Control Panel

Three phase, duplex alternating pump control with intrinsically safe circuits. The Model 324 control panel is designed for applications requiring intrinsically safe float circuits or other circuit extensions. This panel will alternately control two 208/240/480 VAC three phase pumps. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, lift stations, or other installations classified as hazardous locations requiring intrinsically safe circuits.

PANEL COMPONENTS

1. Enclosure measures 16 x 14 x 6 inches (40.64 x 35.56 x 15.24 cm) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Intrinsically Safe Module limits the amount of energy to switches preventing ignition of flammable gases. Intrinsically Safe Partition isolates intrinsically safe wiring. Motor Protective Switches provide adjustable overload, branch circuit protection and pump disconnect. IEC Motor Contactors control pumps by switching electrical lines. HOA Switches for manual pump control (mounted on circuit board). Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/alarm voltage. Alternating Circuit Board provides pump control and alternation of pumps (U.S. Patent # 5,909,352). Green Pump Run Indicator Lights (mounted on circuit board). Control/Alarm Fuse (mounted on circuit board). Float Status Indicator Lights (mounted on circuit board). Input Power Terminal Block Ground Lugs Control/Alarm Power Indicator Light (mounted on circuit board). Control ON/OFF Switch (mounted on circuit board).

6 9 8 18 17 2 3 11 4 12 5 13 14 15 10 16 19 1 7

2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15.

Model Shown 3241W511X

STANDARD ALARM PACKAGE

16. Red Alarm Beacon provides 360° visual check of alarm condition. 17. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 18. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 19. Horn Silence Relay (mounted circuit board). NOTE: other options available.

NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover.

PRICING/ORDERING INFORMATION

Model Number

3241W001H 3241W101H 3241W201H 3241W301H 3241W401H 3241W511H 3241W611H 3241W621H 3241W701H

FEATURES

Shipping Weight

28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs.

AC Voltage

208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC 208/240/480 VAC

Full Load Amps

1.0-1.6 1.6-2.5 2.5-4.0 4.0-6.3 6.0-10.0 9.0-14.0 13.0-18.0 17.0-23.0 20.0-25.0

List Price

$2316.00 $2316.00 $2316.00 $2316.00 $2316.00 $2376.00 $2376.00 $2396.00 $2396.00

Q Industrial control panel is UL Listed relating to hazardous locations with intrinsically safe circuit extensions Q Standard package includes three 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

Panels include three 20' Sensor Floats® normally open control switches. *Model 324 control panels cannot be returned. Please refer to the Product Return section on page 2. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

39

CONTROL PANELS

324

ALARM PACKAGE

W

MODEL 324 ............................................................................................................................................ $2316.00

0 = select options or no alarm package .................................................................................................... - $35.00 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ........................................... Base ________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

PUMP FULL LOAD AMPS

001 = 101 = 201 = 301 = 401 = 511 = 611 = 621 = 701 = 1.0-1.6 FLA .......................................................................................................................................... Base 1.6-2.5 FLA .......................................................................................................................................... Base 2.5-4.0 FLA .......................................................................................................................................... Base 4.0-6.3 FLA .......................................................................................................................................... Base 6.0-10.0 FLA ........................................................................................................................................ Base 9.0-14.0 FLA ..................................................................................................................................... $60.00 13.0-18.0 FLA ................................................................................................................................... $60.00 17.0-23.0 FLA ................................................................................................................................... $80.00 20.0-25.0 FLA ................................................................................................................................... $80.00

________

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ...................................................................................................................... Base X = no floats .............................................................................................................................................. - $75.00 ________

OPTIONS Listed below

................................................................................................................................................................................. ENCLOSURE UPSIZE - If you selected one or more of the options,

Total Options add a one-time $160.00 list enclosure upsize .................................................................................................................................. Enclosure Upsize TOTAL LIST PRICE

________ ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE DESCRIPTION LIST PRICE CODE DESCRIPTION LIST PRICE

1A 1C 3A 3B 3C 3D 4A 4B 4D 5A 5E 5M 6A 6G 8A 8C

Red beacon only / no audio ........................ $20.00 Horn only / no visual .................................... $20.00 Alarm flasher ............................................... $35.00 Manual reset alarm ...................................... $90.00 Red high/low indicator light ....................... $300.00 and alarm activation (4A not needed) Float for low indicator ................................. $25.00 (must select option 3C) Low-level cutout ......................................... $55.00 (select option 4D if floats included, 3C not needed) Red low-level indicator & alarm .................. $70.00 (must select 4A also) Redundant off float switch ......................... $25.00 Thermal cutout/heat sensor auto ................ $80.00 reset (for pumps w/thermal switch leads) Seal failure circuit & red indicator ............ $315.00 (2 wire) Seal failure alarm activation ........................ $60.00 (must select option 5E) Auxiliary alarm contact, form C .................. $15.00 Auxiliary contact, seal fail, ......................... $40.00 normally open (must select option 5E) Elapsed time meter... ................................ .$110.00 Event (cycle) counter .................................. $90.00

10A Clear inner swing-out door w/dead front ................... $190.00 (lights and switches mounted on inner door) 10E Lockable latch ................................................................. $30.00 10G Lightning arrestor ......................................................... $150.00 10K Anti-condensation heater ............................................ $100.00 11C NEMA 1 alarm panel (must select option 6A) ............... $65.00 11D NEMA 4X alarm panel (must select option 6A) .......... $170.00 14B Main disconnect (rotary style, mounted through door, non-fused) 0-20 FLA (total of both pumps) ...................... $285.00 20-50 FLA (total of both pumps) .................... $325.00 16A 10' cord in lieu of 20' (per float) .................................... - $2.00 16B 15' cord in lieu of 20' (per float) ................................... - $1.00 16C 30' cord in lieu of 20' (per float) ...................................... $5.00 16D 40' cord in lieu of 20' (per float) .................................... $15.00 17C Sensor Float® / internally weighted (per float) ........... $5.00 17D Sensor Float® / externally weighted (per float) ......... $7.00 17G MilliAmpMasterTM/ pipe clamp (per float) ...................... $0.00 17H MilliAmpMasterTM/ externally weighted (per float) ....... $7.00 19B Lead lag selector switch ............................................... $15.00 19F Fourth float to separate alarm function from lag ........ $175.00 19G Panel wired to accept fourth control switch ............. $150.00 19T TOA (Test/Off/Automatic) switches and pump run light through door mounted .................................................. $160.00 19U HOA (Hand/Off/Automatic) switches and pump run light through door mounted .................................................. $150.00 19X Door mounted pump run indicator .................................. $40.00 Mechanically-activated Mercury-activated 324 ...... $2316.00 1 ............. Base W ............. Base 401 ............. Base H ............. Base 8A ........ $110.00 8C .......... $90.00 Enclosure Upsize ........ $160.00 TOTAL LIST PRICE $2676.00 LIST PRICE

SAMPLE

MODEL 324 1 W 401 H 8AC

Alarm Package Enclosure Rating Pump Full Load Amps Float Switch Application Options: Elapsed Time Meter, Event (cycle) Counter

40

Cat Page PN 1012509H © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL TD Control Panel

Single phase, simplex timed dosing pump control. The Model TD control panel provides a reliable means of controlling one single phase pump in onsite septic installations. A programmable timer activates a magnetic motor contactor to turn the pump on and off. A low level cutout float overrides the timer to prevent the pump from running dry. An alarm float activates the audio/visual alarm system indicating a high liquid level. Common applications include sand filter systems, pressure distribution systems, mound systems, or any application requiring a timed dose.

PANEL COMPONENTS

1. Enclosure measures 10 x 8 x 4 inches (25.40 x 20.32 x 10.16 cm) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Magnetic Motor Contactor controls pump by switching electrical lines. HOA Switch for manual pump control. Control Fuse Alarm Fuse Float Switch Terminal Block Incoming Power Terminal Block Programmable Timer with separate variable controls allows for setting the on and off times from .05 seconds to 30 hours. Circuit Breaker provides pump disconnect and branch circuit protection.

12 6 11 8 2 7 1 13 9 4 5 3 16 10 15 14 14

2. 3. 4. 5. 6. 7. 8. 9.

10. Spare Fuse 11. Backplate Label includes diagram of float, pump, and power connections. 12. Ground Lug NOTE: Timer Installation Label and Pump/Float Switch Installation Specification Label are located inside the panel on enclosure cover.

Model Shown TD1W914X

STANDARD ALARM PACKAGE

13. Red Alarm Beacon provides 360° visual check of alarm condition. 14. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 15. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 16. Horn Silence Relay (mounted under bracket). NOTE: other options available.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/ or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes one 20' SJE PumpMaster® pump switch and one 20' Sensor Float® Mini control switch Q Complete with step-by-step installation instructions Q Three-year limited warranty

PRICING/ORDERING INFORMATION

Model Number

TD1W904H TD1W914H TD1W924H TD1W104H TD1W114H TD1W124H

Horsepower/ AC Voltage

1 HP/120 VAC 1 HP/120 VAC 1 HP/120 VAC 2 HP/120/208/240 VAC 2 HP/120/208/240 VAC 2 HP/120/208/240 VAC

Full Load Amp

0-7 FLA 7-15 FLA 15-20 FLA 0-7 FLA 7-15 FLA 15-20 FLA

List Price

$670.00 $670.00 $670.00 $730.00 $730.00 $730.00

Shipping Weight

19 lbs. 19 lbs. 19 lbs. 19 lbs. 19 lbs. 19 lbs. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

41

CONTROL PANELS

TD

W

4

$670.00

MODEL TD ...............................................................................................................................................

ALARM PACKAGE

0 = select option (If you select "0", you must select option1F) ................................................................. - $ 20.00 1 = alarm package (includes test/normal/silence switch, red beacon, horn) ................................................. Base

_________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................ Base

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ............................................................................................. $ 60.00 9 = magnetic motor contactor 120V only ....................................................................................................... Base _________

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................... Base 1 = 7-15 FLA ................................................................................................................................................. Base 2 = 15-20 FLA ............................................................................................................................................... Base

PUMP DISCONNECTS

4 = circuit breaker ......................................................................................................................................... Base

FLOAT SWITCH APPLICATION

H = 20' low level cutout (20' SJE PumpMaster®, gray), high level alarm floats (20' Sensor Float® Mini, black) Base X = no floats ............................................................................................................................................ - $ 60.00 _________

OPTIONS

Listed below _________ _________

...................................................................................................................................... Total Options ............................................................................................................................. TOTAL LIST PRICE

..............................................................................................................................................................................................................

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

1F Door mounted alarm indicator with horn .... $30.00 and test/normal/silence switch (must select "0" as an alarm package) 4B Redundant off, alarm activation, red indicator light ......................................... $55.00 (must select option "4D" if floats included) 4D Redundant off float ...................................... $25.00 (20' Sensor Float® Mini) 4E Redundant off float, alarm activation .......... $40.00 (20' SJE PumpMaster® SPDT) 6A Normally open dry auxiliary alarm contacts $40.00 8A Elapsed time meter ..................................... $55.00 8C Event (cycle) counter .................................... $55.00

10E 10K 16A 16B 16C 16D 18A

Lockable latch .......................................... $20.00 Anti-condensation heater ......................... $60.00 10' cord in lieu of 20' (per float) ............... - $2.00 15' cord in lieu of 20' (per float) ............... - $1.00 30' cord in lieu of 20' (per float) .................. $5.00 40' cord in lieu of 20' (per float) ................ $15.00 Timer override float (20' SJE PumpMaster®) ............................ $40.00 19X Externally mounted pump run indicator ... $30.00 21E SJE PumpMaster® in lieu of Sensor Float® Mini (per float) ..................... $5.00

SAMPLE

MODEL TD 1 W 9 1 4 H 4E 18A

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Option: Redundant off float, Timer override float LIST PRICE TD ........ $670.00 1 ............. Base W ............. Base 9 ............. Base 1 ............. Base 4 ............. Base H ............. Base 4E .......... $40.00 18A .......... $40.00 TOTAL LIST PRICE $750.00

Cat Page PN 1011953H © SJE-Rhombus Printed in USA 11/07

42

CONTROL PANELS

MODEL DTD Control Panel

Single phase, duplex timed dosing pump control. The Model DTD control panel provides a reliable means of controlling two single phase 120, 208, or 240 VAC pumps in onsite septic installations. A programmable timer, in conjuction with an alternating circuit board, alternately activates the magnetic contactors to turn the pumps on and off and equalize pump wear. A low level cutout float overrides the timer to prevent the pump from running dry. An alarm float activates the audio/visual alarm system indicating a high liquid level. Common applications include sand filter systems, pressure distribution systems, mound systems, or any application requiring timed dose control.

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). 2. Magnetic Motor Contactors control pumps by switching electrical lines. 3. HOA Switches for manual pump control. 4. Control/Alarm Fuse 5. Float Switch Terminal Block 6. Incoming Power Terminal Block 7. Programmable Timer with separate variable controls allows for setting the on and off times from .05 seconds to 30 hours. 8. Pump Circuit Breakers provide pump disconnects and branch circuit protection. 9. Alternating Circuit Board provides pump control and alternation (U.S. Patent 5,909,352). 10. Spare Fuse 11. Ground Lugs NOTE: Timer Installation Label, Field Wiring Diagram and Pump/Float Switch Installation Specification Label are located inside the panel on enclosure cover.

1 12

7 4 9 8 3 10 14 2 11 15 13 6 5

Model Shown DTD1W104X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/ or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes one 20' SJE PumpMaster® pump switch and one 20' Sensor Float® control switch Q Complete with step-by-step installation instructions

STANDARD ALARM PACKAGE

12. Red Alarm Beacon provides 360° visual check of alarm condition. 13. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 14. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 15. Horn Silence Relay (mounted under bracket). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number

DTD1W904H DTD1W124H

Q Three-year limited warranty

Horsepower/ AC Voltage

1HP/120 VAC 2HP/120/208/240 VAC

Full Load Amps

0-7 FLA 15-20 FLA

List Price

$1340.00 $1400.00

Shipping Weight

20 lbs. 20 lbs.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected] SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

43

CONTROL PANELS

DTD

W

4

$1340.00

MODEL DTD .........................................................................................................................................

ALARM PACKAGE

0 = select option (If you select "0", you must select option1F) .................................................................. - $20.00 1 = alarm package (includes test/normal/silence switch, red beacon, horn) ................................................. Base

_________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................ Base

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ............................................................................................. $ 60.00 9 = magnetic motor contactor 120V only ....................................................................................................... Base _________

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................... Base 1 = 7-15 FLA ................................................................................................................................................. Base 2 = 15-20 FLA ............................................................................................................................................... Base 3 = 20-30 FLA ........................................................................................................................................... $ 50.00

_________

PUMP DISCONNECTS

4 = circuit breaker ......................................................................................................................................... Base

FLOAT SWITCH APPLICATION

H = 20' low level cutout (20' SJE PumpMaster®, gray), high level alarm float (20' Sensor Float®, black) ........ Base X = no floats ............................................................................................................................................. - $60.00 _________

OPTIONS

Listed below _________ _________

...................................................................................................................................... Total Options ............................................................................................................................. TOTAL LIST PRICE

..............................................................................................................................................................................................................

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

1F Door mounted alarm indicator with horn .... $30.00 and test/normal/silence switch (must select "0" for alarm package) 4B Redundant off, alarm activation, red ........... $90.00 indicator (must select option 4D if floats included) 4D Redundant off float (20' Sensor Float®) ...... $25.00 4E Redundant off float, alarm activation .......... $40.00 (20' SJE PumpMaster® SPDT) 6A Normally open dry auxiliary alarm contacts $50.00 8A Elapsed time meters ................................ $110.00 8C Event (cycle) counters .................................. $90.00

10E 10K 16A 16B 16C 16D 18A

Lockable latches ......................................... $30.00 Anti-condensation heater ........................ $100.00 10' cord in lieu of 20' (per float) ................. - $2.00 15' cord in lieu of 20' (per float) .................... - 1.00 30' cord in lieu of 20' (per float) ................... $ 5.00 40' cord in lieu of 20' (per float) .................. $15.00 Timer override float ..................................... $40.00 (20' SJE PumpMaster®) 19X Externally mounted pump run indicators ... $40.00 21E SJE PumpMaster® in lieu of Sensor Float® (per float) .............................. $5.00

SAMPLE

MODEL DTD 1 W 9 1 4 H 4E 18A

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Option: Redundant off float, Timer override float

LIST PRICE

DTD ...... $1340.00 1 ............. Base W ............. Base 9 ............. Base 1 ............. Base 4 ............. Base H ............. Base 4E .......... $40.00 18A .......... $40.00

TOTAL LIST PRICE $1420.00

Cat Page PN 1011951H © SJE-Rhombus Printed in USA 11/07

44

CONTROL PANELS

MODEL PS Control Panel

Single phase, duplex motor contactor control/programmable timed dosing control panel. The PS series control panel provide a reliable means of controlling both pump chamber and sand filter pumps in an onsite septic installation.

PANEL COMPONENTS

1. Enclosure measures 14 x 12 x 6 inches (35.56 x 30.48 x 15.24 cm); NEMA 4X (ultraviolet stabilized thermoplastic) with removable mounting feet for indoor or outdoor use. 2. Pump Chamber Magnetic Motor Contactor controls pump chamber pump by switching electrical lines. 3. Sand Filter Magnetic Motor Contactor controls pump chamber pump by switching electrical lines. 4. Alarm/Control Fuse 5. Float Switch Terminal Block 6. Control/Pump Power Terminal Block 7. Programmable Timer features separate variable controls to allow for pump chamber pump on/off time settings from .05 seconds to 30 hours. 8. Pump Chamber Circuit Breaker provides pump chamber disconnect and provides branch circuit protection. 9. Sand Filter Circuit Breaker provides sand filter pump disconnect and provides branch circuit protection. 10. HOA Switches provide manual pump control. 11. Ground Lugs 12. Spare Fuse NOTE: Wiring Diagram, Pump Specification Label and Timer Installation Label are located inside the panel on enclosure cover.

1 6 13

7 4

8 9

10 12 15

2 3 11

14 16 5

Model Shown PS1W104X

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes two 20' SJE PumpMaster® pump switches, one 20' SJE PumpMaster® SPDT pump switch and one 20' Sensor Float® control switch Q Complete with step-by-step installation instructions

STANDARD ALARM PACKAGE

13. Red Alarm Beacon provides 360o visual check of alarm condition. 14. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 15. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 16. Horn Silence Relay (mounted under bracket). NOTE: other options available.

PRICING/ORDERING INFORMATION

Model Number

PS1W904H PS1W914H PS1W924H PS1W104H PS1W114H PS1W124H

AC Voltage

120 VAC 120 VAC 120 VAC 120/208/240 VAC 120/208/240 VAC 120/208/240 VAC

Full Load Amp

0-7 FLA 7-15 FLA 15-20 FLA 0-7 FLA 7-15 FLA 15-20 FLA

List Price

$1215.00 $1215.00 $1215.00 $1275.00 $1275.00 $1275.00

Shipping Weight

20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs.

Q Three-year limited warranty

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

45

CONTROL PANELS

PS

ALARM PACKAGE

W

4

$1215.00

MODEL PS .............................................................................................................................................

0 = no alarm (If you select "0", you must select option 1F) ....................................................................... - $20.00 1 = alarm package (includes test/normal/silence switch, red beacon, horn) ................................................. Base

_________

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................ Base

STARTING DEVICE

1 = magnetic motor contactor 120/208/240V ............................................................................................. $ 60.00 9 = magnetic motor contactor 120V only ....................................................................................................... Base _________

PUMP FULL LOAD AMPS

0 = 0-7 FLA ................................................................................................................................................... Base 1 = 7-15 FLA ................................................................................................................................................. Base 2 = 15-20 FLA ............................................................................................................................................... Base

PUMP DISCONNECTS

4 = circuit breaker ......................................................................................................................................... Base

FLOAT SWITCH APPLICATION

H = Two 20' SJE PumpMasters® (gray) - low level cutout (pump chamber) and on/off (sand filter) one 20' SJE PumpMaster® SPDT (gray) - high alarm (sand filter) and pump chamber cutoff one 20' Sensor Float® (black) - high alarm (pump chamber) ................................................................... Base X = no floats ........................................................................................................................................... - $130.00

_________

OPTIONS

Listed below _________ _________

...................................................................................................................................... Total Options ............................................................................................................................. TOTAL LIST PRICE

..............................................................................................................................................................................................................

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

CODE DESCRIPTION

LIST PRICE

1F Door mounted alarm indicator with horn ...... $30.00 and test/normal/silence switch (must select "0" for alarm package) 3F High level indicators ...................................... $65.00 4B Redundant off, alarm activation, red ............. $90.00 indicators (must select option "4D" if floats included) 4D Redundant off float (two 20' Sensor Floats®) ....... $50.00 4E Redundant off, alarm activation .................... $40.00 must select 4D if floats included 6A Normally open dry auxiliary alarm contacts .. $50.00 8A Elapsed time meters ................................... $110.00 8C Event (cycle) counters .................................... $90.00

10E 10K 16A 16B 16C 16D 18A

Lockable latches ......................................$30.00 Anti-condensation heater ...................... $100.00 10' cord in lieu of 20' (per float) ............... - $2.00 15' cord in lieu of 20' (per float) ............... - $1.00 30' cord in lieu of 20' (per float) ................. $ 5.00 40' cord in lieu of 20' (per float) ................ $15.00 Timer override float .................................. $40.00 (20' SJE PumpMaster®) 19X Externally mounted pump run indicators $40.00 21E SJE PumpMaster® in lieu of Sensor Float® (per float) ............................ $5.00

SAMPLE

MODEL PS 1 W 9 1 4 H 4DE 18A

Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Option: Redundant off float, Timer override float, Alarm activation

LIST PRICE PS ...... $1215.00 1 ............. Base W ............. Base 9 ............. Base 1 ............. Base 4 ............. Base H ............. Base 4D .......... $50.00 4E .......... $40.00 18A .......... $40.00 TOTAL LIST PRICE $1345.00

Cat Page PN 1011952H © SJE-Rhombus Printed in USA 11/07

46

CONTROL PANELS

Installer Friendly SeriesTM Drip Control Panel

Single phase, simplex subsurface drip irrigation panel for pump control and system monitoring. The Installer Friendly SeriesTM Drip irrigation control panel is designed to control one 120V or 230V single phase pump for subsurface irrigation systems. The IFS Drip panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring system operation: rest for standard time, rest for peak enable time, spin filter flush time, dose time, field flush time, field drain time, and low alarm activation.

A B D F G I H J N L M O 2 K C

E

TOUCH PAD FEATURES

A. B. C. Alarm Power Indicator/Fuse. LED indicator light illuminates if alarm power is present in panel. Alarm Power Replace Indicator illuminates if alarm fuse is blown. Control Power Indicator/Fuse. LED indicator light illuminates if control power is present in panel. HOA (Hand/Off/Automatic) Indicators/Buttons control pump mode with LED indication. Float Status Indicators illuminate when floats are activated. Alarm will activate and indicator will flash if a float operates out of sequence. Pump Run Indicator illuminates when pump is called to run. Cycle Status Indicators allows user to see which cycle (dose, flush, or drain) is activated. Advance and Pause Buttons allow user to cycle though system functions for testing. Rest Time Indicator illuminates in between cycles. Count Indicator illuminates when viewing panel data. Program Indicator illuminates when programming panel. Flush Valve Indicator illuminates when flush valve is called to energize. Seven-Segment LED Display shows high water alarm count, float status sequence error count, low level cutout float open low alarm count, standard dose count, power-fail count, pump on/off cycle count, pump run times (hh:mm), and peak does count. 7. 8. 9.

1 10

NOTE: If control power is not present panel will go into alarm mode. D. E. F. G. H. I. J. K. L. N.

3 5 6 7 4 8 11 9

Float Connections Valve Connections Magnetic Motor Contactor controls pump by switching electrical lines.

M. Spin Valve Indicator illuminates when spin valve is called to energize.

10. Large Incoming Power/Pump Connection Terminal Block 11. Ground Lugs NOTE: Schematic/Wiring Diagram, Pump Specification Label, Input Display Code Label, and Counter Display Code Label are on inside cover for viewing/programming digital display.

O. Next, Up, Select Buttons are used to navigate through the display. NOTE: LED display will turn off after one minute of not being used.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes four control switches Q Optional pressure switch for aerobic applications Q Complete, easy step-by-step installation instructions Q Three-year limited warranty

PANEL COMPONENTS

1. NEMA 4X enclosure ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use measures 12 x 10 x 6 inches (30.48 x 25.40 x 15.24 cm). Red Alarm Beacon provides 360o visual check of alarm condition. Exterior Alarm Test/Normal/Silence Switch allows horn and beacon to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Circuit Breaker provides pump disconnect and branch circuit protection. Circuit Board provides power to main circuit board and contains terminal blocks for float and valve connections.

2. 3.

4. 5. 6.

PRICING/ORDERING INFORMATION

Part Number 1018134 1021573 1021563 Description IFS Drip Panel IFS Drip w/PS IFS Drip w/PS VAC 120/208/240V 120V 120/208/240V FLA 7-15 7-15 7-15 List Price $1260.00 $1325.00 $1360.00

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

47

CONTROL PANELS

Installer Friendly SeriesTM Drip Control Panel

IFS Drip Control Panel Operation:

Four (4) float switches (low level, timer on/off, peak enable, and high alarm floats) control the operation. Timers internal to the PCB control the pump dosing cycles. When the liquid level activates the timer on float, the following operations occur: 1. 2. 3. 4. 5. 6. Rest time The pump turns on and the spin filter valve opens for the user-programmed length of time. The spin filter valve closes and the pump continues to run for the user-programmed dose time. The pump continues to run and the flush valve opens for the user-programmed length of time. The pump turns off and the flush valve remains open for the user-programmed drain time. The flush valve closes for the user-programmed off time.

Vent

Vent

Drip Line Flush Manifold Drip Line Drip Line Spin Filter Spin Valve Supply Manifold

Flush Valve

Supply High Alarm Peak Enable On / Off Low Level Cutout Pump Pre-Treatment Tank Dose Tank

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753) Fax 218-847-4617

48

www.sjerhombus.com [email protected]

©SJE-Rhombus CatPage PN 1018316E Printed in USA 11/07

CONTROL PANELS

MODEL DP Control Panel

Subsurface drip panel controllers for irrigation systems. The Model DP control panels are PLC-based (Programmable Logic Controller) subsurface drip panels which control one single phase (120V or 230V) pump and two valves (flush and spin valves) for irrigation systems. The PLC can be programmed to contain all timer settings and monitoring information for the system via a touch pad and screen displays. Each panel features these PLC log functions:

13 4 10 11 5 3 8 16 1 7 6 2 15 14 9

Q Pump Elapsed Time Meter Q Pump Cycle Counter Q Pump Fail Counter Q High Alarm Counter Q Override Float Counter

Model DP1

13 4 11 5 12 3 16 10 1 7 6 15 2 14 8

PANEL COMPONENTS

1. NEMA 4X enclosure (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) for Model DP1 measures 14" x 12" x 6"; Model DP2 measures 16" x 14" x 6". Magnetic Motor Contactor controls pump by switching electrical lines. HOA (Hand/Off/Automatic) Switch for manual pump control. Programmable Logic Controller HOA (Hand/Off/Automatic) Switch Flush Valve Incoming Power Terminal Block/Pump/Control/Alarm Circuit Breaker provides pump disconnect and branch circuit protection. Float/Valves Terminal Block Ground Lugs

2. 3. 4. 5. 6. 7. 8. 9.

Model DP2

9

STANDARD ALARM PACKAGE

13. Red Alarm Beacon provides 360o visual check of alarm condition. 14. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). 15. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in alarm condition. Alarm automatically resets once alarm condition is cleared. 16. Horn Silence Relay

10. Fuses 11. HOA (Hand/Off/Automatic) Spin Filter 12. HOA (Hand/Off/Automatic) Switch Zone Valves

PANEL OPERATION

Four (4) float switches (low level float, timer on float, override float, and high level float) control the operation. Timers internal to the PLC control the pump dosing cycles. When the liquid level reaches the timer on float, the following operations occur: 1. 2. 3. 4. 5. The pump will turn on and the spin filter valve will be activated for the user-programmed length of time. The spin filter valve will then close and the pump will continue to run for the user-programmed timer on or override timer on time. The pump will continue to run and the flush valve will be activated for the user-programmed length of time. The pump will then be turned off and the flush valve will remain on for the user-programmed drain time. The flush valve will then close for the user-programmed off time.

FEATURES

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes four 20' Sensor Float® control switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

After the user-programmed number of cycles, the flush valve will remain activated during a dose for each zone. This will occur until each zone has been fully activated.

PRICING/ORDERING INFORMATION

Model Number Description DP1 DP2

Operates with a hydraulically-controlled ratcheting valve for zone control (valve not included). Operates up to 4 independent electro-mechanical valves for zone control (valve not included).

VAC 120/230V 120/230V

FLA 7-15 7-15

List Price $1512.00 $1958.00

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

49

CONTROL PANELS

NOTES:

22650 County Highway 6 Q PO Box 1708 Q Detroit Lakes, MN 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q Email: [email protected] www.sjerhombus.com 50

©SJE-Rhombus CatPage PN 1017232E Printed in USA 11/07

CONTROL PANELS

MODEL RP Control Panel

Single phase, simplex plug-in pump switch control. The Model RP control panel provides customers with a reliable means of controlling one 120, 208, or 240 VAC single phase pump in water and wastewater installations. A pump float switch turns the pump on and off. If an alarm condition occurs, an additional alarm float activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems, and lift stations.

PANEL COMPONENTS

1. Enclosure measures 8 x 6 x 4 inch (20.32 x 15.24 x 10.16 cm) with removable mounting feet, NEMA 4X rated, ultraviolet stabilized thermoplastic for indoor and outdoor use. Alarm Fuse Terminal Block Red Alarm Beacon provides 360° visual check of alarm condition. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Note: To place alarm system back into the normal mode after silencing the alarm, the switch must be manually placed into normal mode. Receptacle for use with piggy-back pump switch. Ground Lug (behind terminal block).

11 7 8 3 6 4 1 2

2. 3. 4. 5. 6.

7. 8.

5

NOTE: Schematic/Wiring Diagram is located inside the panel on enclosure cover. Indoor/Outdoor

PRICING/ORDERING INFORMATION

Model Number Horsepower/ AC Voltage Full Load Amps

0-15 FLA 0-12 FLA

FEATURES

Shipping Weight

10 lbs. 10 lbs.

List Price

$318.00 $330.00

RP11W510H 1HP/120 VAC RP21W510H 2HP/208/240 VAC

Q Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Standard package includes float switches Q Complete with step-by-step installation instructions Q Three-year limited warranty

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

51

CONTROL PANELS

RP__

1

W

1

0

MODEL RP1 OR RP2

MODEL RP1 - 120 VAC ............................................................................................................................ $ 318.00 MODEL RP2 - 208/240 VAC ..................................................................................................................... $ 330.00

________

ALARM PACKAGE

1 = Alarm package (includes test/normal/silence switch, red light, horn and float) ......................................... Base

ENCLOSURE RATING

W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................... Base

STARTING DEVICE

2 3 4 5 6 = SJE PumpMaster® Plus pump switch (0-15 FLA) ................................................................................. - $10.00 = 120 VAC Double Float® pump switch (0-15 FLA) .................................................................................. $ 30.00 = 240 VAC Double Float® pump switch (0-12 FLA) ................................................................................. $ 30.00 = Super Single® pump switch (120V = 0-15 FLA) (208/240V = 0-12 FLA) .................................................. Base = No pump switch ................................................................................................................................... - $50.00

________

PUMP FULL LOAD AMPS

1 = 0-15 FLA ................................................................................................................................................. Base

PUMP DISCONNECTS

0 = no pump disconnect ................................................................................................................................ Base

FLOAT SWITCH APPLICATION

H or L = pump down or pump up ..................................................................................................................... Base X = no floats ............................................................................................................................................... - $25.00 ________

OPTIONS Listed below

Total Options TOTAL LIST PRICE __________ __________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

3A Alarm flasher ...................................................................... $45.00 10E Lockable latch ..................................................................... $20.00 16A 10' cord in lieu of 20' (per float) ......................................... -$2.00 (Does not apply for Double Float® pump switch) 16B 15' cord in lieu of 20' (per float) ........................................ -$1.00 16C 30' cord in lieu of 20' (per float) .......................................... $5.00 16D 40' cord in lieu of 20' (per float) ........................................ $15.00 17A SJE SignalMaster® in lieu of Sensor Float® ......................... -$2.00 (alarm float only) 17E Sensor Float® Mini in lieu of Sensor Float® ......................... -$2.00 (alarm float only)

SAMPLE

MODEL RP1 1 W 5 1 0 H 3A

LIST PRICE Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Flasher RP1 ........ $318.00 1 ............. Base W ............. Base 5 ............. Base 1 ............. Base 0 ............. Base H ............. Base 3A .......... $45.00 TOTAL LIST PRICE $363.00

Cat Page PN 1011961J © SJE-Rhombus Printed in USA 11/07

52

JB PLUGGER System

Easy to install junction box provides convenient wiring connection for use with one single phase pump in effluent and sewage chambers. This junction box provides a convenient location to connect all wiring required for a typical pumping station installation. The junction box employs a receptacle to accept a 120 VAC or 230 VAC piggy-back plug and a pump plug. The JB Plugger also features an easy-to-use terminal strip which can be used for connecting an alarm system in the junction box. The JB Plugger package ensures a liquid-tight seal and strain relief for the cable entering the junction box from the pumping station.

CONTROL PANELS

FEATURES

NEMA 4X enclosure with hinged door. Separate alarm and pump control circuit. Receptacle for pump and pump switch (120V or 230V). Tank Alert® AB alarm system provides high or low level alarm (optional). Pump float provides pump control (optional). Control float provides alarm activation (optional). Riser extension coupling and washers. Custom engineered liquid-tight cable seal. Strain relief for pump and float cords provided by cord seal. Electrical conduit hub. Terminal strip for use with alarm system. Entire control system (panel and switches) is UL and cUL Listed to meet and/or exceed industry safety standards. Three-year limited warranty.

SPECIFICATIONS

VOLTAGE: 120 VAC or 230 VAC ENCLOSURE: 6 x 6 x 4 inch (15.24 x 15.24 x 10.16 cm), NEMA 4X weatherproof thermoplastic RECEPTACLE: 120 VAC NEMA type 5-15; 230 VAC NEMA type 6-15 CORD SEAL: Liquid-tight cord seal with strain relief

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

53

CONTROL PANELS

JB Plugger System

Easy to install junction box provides convenient wiring connection for use with one single phase pump in effluent and sewage chambers.

120 VAC

Part #

1007936 1012344 1012341 1011645

Description

JBP No alarm or floats JBP Tank Alert AB & 15' Sensor Float Mini JBP Tank Alert® AB, 15' Junior Super Single® & 15' Sensor Float® Mini JBP Tank Alert AB, 15' Double Float & 15' Sensor Float Mini

® ® ® ® ®

List Price

$173.00 $277.00 $331.00 $387.00

Shipping Weight

3.5 lbs. 9.6 lbs. 9.5 lbs. 11.4 lbs.

230 VAC

Part #

1007937 1012345 1012342 1012343

Description

JBP No alarm or floats JBP Tank Alert AB & 15' Sensor Float Mini JBP Tank Alert® AB, 15' Junior Super Single® & 15' Sensor Float® Mini JBP Tank Alert AB, 15' Double Float & 15' Sensor Float Mini

® ® ® ® ®

List Price

$180.00 $284.00 $338.00 $396.00

Shipping Weight

3.6 lbs. 9.7 lbs. 9.6 lbs. 11.5 lbs.

SPECIFICATIONS

VOLTAGE: 120 VAC or 230 VAC ENCLOSURE 6 x 6 x 4 inch (15.24 x 15.24 x 10.16 cm) NEMA 4X weatherproof thermoplastic with hinged door. SEPARATE ALARM AND PUMP CONTROL SWITCH RECEPTACLE FOR PUMP AND PUMP CIRCUIT 120V or 230V RISER EXTENSION COUPLING AND WASHERS CORD SEAL Custom engineered to provide liquid tight seal and provide strain relief for pump and float cords. ELECTRICAL CONDUIT HUB

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

54

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012511G © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

PS PATROLTM System

Provides convenient wiring connection and system monitoring for pump station applications. The PS PatrolTM system features a built-in high water alarm and provides a convenient location to connect all wiring required for a pumping station installation. The PS PatrolTM system also employs a receptacle to accept either a 120 VAC or 230 VAC pump and/or piggy-back style pump switch. Three PS PatrolTM system models are available; a 120V, a 230V and a 9 VDC model.

STANDARD FEATURES

Q Q Q Q Q Q Q Q Q Q Q Q Q Q

Pedestal rated for outdoor use. Built-in high water alarm (except in PSAB model). Pull out assembly for easy wiring. Control switch provides alarm activation. Convenient test/normal/silence switch mounted externally for easy operation (except in PSAB model). 360o audio/visual check of alarm condition (except in PSAB model). PSAB model includes Tank Alert® AB alarm system (no built-in alarm). Complete step-by-step installation instructions. Separate 120V alarm and pump circuits. Receptacle for 120V or 230V pump and/or pump switch. Vent holes on side of post to help prevent moisture condensation inside. No external cords (except in PSAB model). CSA Certified. Three-year limited warranty.

U.S. Patent No. 7,218,511

120V or 230V SPECIFICATIONS

ALARM VOLTAGE: 120 VAC, 50/60 Hz PUMP VOLTAGE: 120 VAC or 230 VAC, 50/60 Hz ENCLOSURE SIZE: 5" X 5" X 4' (12.7 x 12.7 x 121.9 cm) RECEPTACLE: 120 VAC - NEMA type 5-15 or 230 VAC - NEMA type 6-15 ALARM FLOAT: Sensor Float® control switch with mounting clamp ALARM HORN: 83 to 85 decibel rating

9 VDC SPECIFICATIONS

VOLTAGE: 120 VAC, 50/60 Hz ENCLOSURE SIZE: 5" X 5" X 4' (12.7 x 12.7 x 121.9 cm) ALARM VOLTAGE: 9 VDC RECEPTACLE: 120 VAC - NEMA type 5-15 CORD SEAL: Liquid-tight cord seal with strain relief ALARM FLOAT: Sensor Float® control switch with mounting clamp ALARM HORN: 83 to 85 decibel rating

9 VDC MODEL

Q Requires only one incoming power for pump and alarm. If power failure occurs during an alarm condition, horn will operate on 9 volt DC battery back-up system. Q Liquid-tight cord seal for pump and pump switch. Q Strain relief for pump and pump switch cords provided by cord seal.

OPTIONS

Q Mercury or mechanical pump switches. Q Various cord lengths. Q Assembly kit for 120V or 230V models only. Q Pump circuit breaker. (120V models only)

PSAB ALARM SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) Secondary: 9 VDC BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inch (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic. ALARM HORN: 87 decibels at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power. (Voltage across terminals is 8-9 VDC). FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp

PRICING/ORDERING INFORMATION

Part #

1018430 1018438 1018903 1019021

Model Number

PSP120V6H PSP120V6H22F PSP120V6H150P PSP120V6H151P

Description

List Ship FLA Price Weight*

13 lbs. 13 lbs. 13 lbs. 13 lbs. 13 lbs. 13 lbs. 14 lbs. 13 lbs. 13 lbs. 16 lbs. 14 lbs. 10 lbs.

1019300 PSP120V6H150P22F 1019301 PSP120V3H150P22F 1018429 1018426 1018444 1018434 PSP120V1H PSP9V6H PSP230V6H PSAB6H16B17A

PSP 120V, 120V alarm, 0-15 $245.00 no pump switch PSP 120V, 120V alarm, no 0-15 $300.00 pump switch, assembly kit PSP 120V, 120V alarm, no 0-7 $305.00 pump switch, 15A circuit bkr PSP 120V, 120V alarm, no 7-15 $305.00 pump switch, 20A circuit bkr PSP 120V, 120V alm, no 0-7 $360.00 pump sw, 15A cb, assy kit PSP 120V, 120V alm, 20' DF 0-7 $452.00 pump sw, 15A cb, assy kit PSP 120V, 120V alarm, 20' SJE PumpMaster® PSP 120V, 9 VDC alarm, no pump switch PSP 230V, 120V alarm, no pump switch PSP, 120V TAAB alarm, 15' SJE SignalMaster® PSP, 120V, 120V alarm, JSS pump switch, 15A circuit bkr Riser Extension Coupling and Washers 0-13 $290.00 0-15 $245.00 0-15 $280.00 0-15 $218.00 0-7 $359.73 $55.00

SEE BACKSIDE FOR PRICING/ ORDERING INFORMATION.

1020081 PSP120V6H150P16B 1011551 Assembly Kit

PS PatrolTM system includes one 20' Sensor Float® normally open control switch. *Due to enclosure size, shipping rate is calculated at 30 lbs. when ordering one (1) PS PatrolTM system.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

55

CONTROL PANELS

PSP MODEL PSP ................................................................................................................................................................. $245.00

MODEL

120V ............................................................................................................................................................... Base 230V ............................................................................................................................................................ $35.00 9V ................................................................................................................................................................... Base AB ............................................................................................................................................................... -$24.00

________

STARTING DEVICE

1 2 3 4 5 6 = SJE PumpMaster® pump switch (0-13 FLA) ........................................................................................... $45.00 = SJE PumpMaster® Plus pump switch (0-15 FLA) ................................................................................... $60.00 = 120 VAC Double Float® pump switch (0-15 FLA) .................................................................................. $95.00 = 230 VAC Double Float® pump switch (0-12 FLA) ................................................................................... $95.00 = Super Single® pump switch (120V = 0-15 FLA) (208/230V = 0-12 FLA) ............................................... $77.00 = No pump switch ........................................................................................................................................ Base

________

FLOAT SWITCH APPLICATION

H = pump down ............................................................................................................................................... Base X = no floats ................................................................................................................................................ -$25.00 ________

OPTIONS Listed below

Total Options TOTAL LIST PRICE _________ _________

CODE DESCRIPTION

LIST PRICE

16A 10' cord in lieu of 20' (per float) ......................................... -$2.00 (Does not apply for Double Float® pump switch) 16B 15' cord in lieu of 20' (per float) ......................................... -$1.00 16C 30' cord in lieu of 20' (per float) .......................................... $5.00 16D 40' cord in lieu of 20' (per float) .......................................... $7.00 15_P Pump breaker (120V only) ................................................. $60.00

specify 0 or 1 after number 15 followed by letter "P"

0 = 15 amp breaker (0-7 FLA) 1 = 20 amp breaker (7-15 FLA)

(Ex. 151P = 20 amp breaker, 7-15 FLA)

17A SJE SignalMaster® / mounting strap / in lieu of Sensor Float ® (alarm float) ................................................. -$2.00 22F PSP Assembly Kit (120V or 230V only) ............................ $55.00

SAMPLE

MODEL PSP 120V 2 H 16C

LIST PRICE 120V Alarm Model Starting Device Float Switch Application Options: 30' Cord in lieu of 20' PSP ........ $245.00 120V ............. Base 2 .......... $60.00 H ............. Base 16C .......... $10.00 TOTAL LIST PRICE $315.00

56

Cat Page PN 1012520J © SJE-Rhombus Printed in USA 11/07

CONTROL PANELS

MODEL 126 Control Panel

Single phase, duplex alternating pump control with override. The Model 126 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water well installations. The alternating action provides alternation between two wells. In addition to the alternating pump control, this system provides override control to maintain system pressure upon high demand or should either pump fail.

PANEL COMPONENTS

1. Enclosure Model 1260I000X: measures 10 x 8 x 4 inches (25.4 x 20.32 x 10.16 cm). Choice of NEMA 1 (steel for indoor use) or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for indoor/outdoor use). Model 1260I120X: measures 12 x 10 x 6 inches (30.48 x 25.4 x 15.24 cm). Choice of NEMA 1 (steel for indoor use) or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for indoor/outdoor use). 2. 3. 4. 5. 6. 7. 8. 9. Magnetic Motor Contactors (Model: 1260I120X) control pumps by switching electrical lines. HOA Switches for manual pump control. Alternating Circuit Board provides pump control and alternation (patented). Green Pump Run Indicator Lights Field Wiring Label Incoming Pump Power/Control Power Terminal Block Pressure Switch Terminal Block Control Power/Pressure Switch Terminal Block

3 5 6 12 9 1 4 10 11

Model Shown 1260I000X

(without contactors)

1

11 10

4

10. Control Fuse 11. Control Relay provides lag function. 12. Ground Lugs

3

5

6

8

7

2

12

Model Shown 1260I120X

(with contactors)

PRICING/ORDERING INFORMATION

Model Number

1260I000X 1260I100X 1260I110X 1260I120X 1260I130X 1260W000X 1260W100X 1260W110X 1260W120X 1260W130X

FEATURES

Shipping Weight

20 lbs. 25 lbs. 25 lbs. 25 lbs. 25 lbs. 15 lbs. 20 lbs. 20 lbs. 20 lbs. 20 lbs. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

VAC

120V 120/208/240V 120/208/240V 120/208/240V 120/208/240V 120V 120/208/240V 120/208/240V 120/208/240V 120/208/240V

FLA

0 0-7 7-15 15-20 20-30 0 0-7 7-15 15-20 20-30

NEMA Rating

1 1 1 1 1 4X 4X 4X 4X 4X

List Price

$477.00 $557.00 $557.00 $557.00 $575.00 $527.00 $607.00 $607.00 $607.00 $625.00

Q Entire control system is UL Listed to meet and/or exceed industry safety standards Q Dual safety certification for the United States and Canada Q Complete with step-by-step installation instructions Q Three-year limited warranty

SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.

www.sjerhombus.com

57

CONTROL PANELS

126

0

0

X

MODEL 126 ............................................................................................................................... $477.00

ALARM PACKAGE

0 = no alarm package .................................................................................................................................... Base

ENCLOSURE RATING

I = Indoor, NEMA 1 (metal) ........................................................................................................................... Base W = Weatherproof, NEMA 4X (engineered thermoplastic) ............................................................................ $50.00 ________

STARTING DEVICE

0 = no starting device - control only (must select "0" for pump full load amps) ............................................. Base 1 = magnetic motor contactor 120/208/240V ............................................................................................. $80.00

PUMP FULL LOAD AMPS

0 1 2 3 = 0-7 FLA .................................................................................................................................................. Base = 7-15 FLA ................................................................................................................................................ Base = 15-20 FLA .............................................................................................................................................. Base = 20-30 FLA ........................................................................................................................................... $18.00

________

PUMP DISCONNECTS

0 = no pump disconnect ............................................................................................................................... Base

SWITCH APPLICATION

X = no pressure switches ............................................................................................................................... Base

OPTIONS Listed below

Total Options TOTAL LIST PRICE ________ ________

If additional features are required, call the factory for a quote on an Engineered Custom control panel.

CODE

DESCRIPTION

LIST PRICE

6T Normally open non-powered chemical feed pump contacts ............................. $60.00 10E Lockable latch - NEMA 4X ................... $30.00 10E Lockable latch - NEMA 1 ...................... $50.00 Motor saver protection ............... Call for quote

SAMPLE

MODEL 126 0 I 1 1 0 X 6T 10E

LIST PRICE Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Switch Application Options: Normally Open Non-Powered Chemical Feed Pump Contacts, Lockable Latch 126 ........ $477.00 0 ............. Base I ............... Base 1 ............. Base 1 ............. Base 0 ............. Base X ............. Base 6T .......... $60.00 10E .......... $50.00 $587.00

TOTAL LIST PRICE

58

Cat Page PN 1011944H © SJE-Rhombus Printed in USA 11/07

TANK ALERT® AB Alarm System

Easy-to-install liquid level alarm system with auto-reset and battery backup features for indoor use. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert® AB alarm system can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset.

ALARM SYSTEMS

A green "Power On" light indicates 120 VAC primary power to the alarm. Low battery chirp feature indicates when battery should be replaced.

FEATURES

Q NEMA 1 enclosure, designed for ease of installation, rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch. Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q Can be used with any UL Listed / Recognized switching mechanism rated to include 1 amp, 9 VDC load. Q If primary power fails, the alarm system continues to work due to battery backup feature. (Battery not included.) Q Complete package includes standard SJE SignalMaster® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. SJE SignalMaster® control switch passes NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Low battery chirp. Q Easy access battery compartment. Q External terminal block for easy float switch installation. Q CSA Certified. Q UL Listed. Q Three-year limited warranty.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) Secondary: 9 VDC BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inch (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic. ALARM HORN: 87 decibels at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power. (Voltage across terminals is 8-9 VDC). FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp Cable: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, waterresistant (CPE) Float: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 140oF (60oC) AUXILIARY ALARM CONTACTS (OPTIONAL):

(CSA certified only unit)

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q auxiliary dry normally open and normally closed contacts. (Tank Alert® AB with auxiliary contacts included is CSA certified only.) Q splice kit.

Voltage: 120 VAC Current: 5 amps maximum N/O 3 amps maximum N/C

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

59

TANK ALERT® AB Alarm System

Easy-to-install liquid level alarm system with auto-reset and battery backup features for indoor use.

PRICING/ORDERING INFORMATION 120 VAC

Part #

1011421 1011422 1011423 1011424

Description

TA AB-01H (120 VAC w/15' SJE SignalMaster High) TA AB-01H (120 VAC w/15' Sensor Float High) TA AB-01X (120 VAC no float) TA AB-01L (120 VAC w/15' SJE SignalMaster Low)

® ® ®

Suggested List Price

$94.50 $97.65 $68.25 $94.50

Shipping Weight

2.73 lbs. 2.81 lbs. 1.44 lbs. 2.73 lbs.

OPTIONS

CONTROL SWITCH OPTIONS The Tank Alert® AB alarm system comes standard with a 15ft SJE SignalMaster® control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with "no float" to the price of the float switch.

ALARM SYSTEMS

H = High Level L = Low Level X = No Float

MASTER CARTON holds 16 boxed units.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 50/60 Hz, 2.4 watts max. (alarm condition) Secondary: 9 VDC BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inches (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic ALARM HORN: 87 decibles at 10 feet (3 meters) AUXILIARY ALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max N/O, 3 amp max N/C (CSA certified only unit) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: for float switch connection only (voltage across terminals is 8-9 VDC) FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 140oF (60oC)

OTHER INFORMATION

Option Description

AUX Auxiliary Alarm Contacts (CSA certified only unit)

Price

$15.75

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

60

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012194G © SJE-Rhombus Printed in USA 11/07

TANK ALERT® ABP Alarm Panel

Easy-to-install liquid level alarm panel with auto-reset , battery backup, and 120 VAC pump receptacle for indoor use. The Tank Alert® ABP indoor alarm panel monitors and controls liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. Two switches, one for the pump and one for the high water alarm, are spliced together for easy installation. The alarm panel also features a 120 VAC receptacle on the bottom to plug in the pump power cord. The Tank Alert® ABP alarm panel horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. A green "Power On/Pump Run" light indicates 120 VAC primary power to the alarm panel and also flashes to indicate the pump run status. Low battery chirp feature indicates when battery should be replaced.

Patent Pending

ALARM SYSTEMS SYSTEMS ALARM

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 60 Hz, 2.4 watts max. Secondary: 9 VDC BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inch (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic. ALARM HORN: 87 decibels at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power (voltage across terminals is 8-9 VDC). CONTROL SWITCHES: two-factory spliced SJE MilliAmpMasterTM control switches with mounting clamps Cable: 10 feet (3 meters), flexible 18 gauge, 3 conductor (UL) SJOW, waterresistant (CPE) Floats: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 140oF (60oC) PUMP CONTROL: Voltage: 120 VAC, 60 Hz, 13.8 amp max. NEMA 5-15R receptacle

FEATURES

Q NEMA 1 enclosure, designed for ease of installation, rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on/pump run" light, alarm "test" switch, horn "silence" switch. Q Manual pump run operation. Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q 6 foot (1.8 meter) power cord. Q If primary power fails, the alarm system continues to work due to battery backup feature. (Battery not included.) Q Complete package includes two factory-spliced SJE MilliAmpMasterTM control switches with 10 feet (3.05 meters) of cable and mounting clamps. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q 120V receptacle on bottom to plug in pump power cord. Q Low battery chirp. Q Easy access battery compartment. Q External terminal block for easy float switch installation. Q UL/CUL Listed. Q Three-year limited warranty.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

61

TANK ALERT® ABP Alarm Panel

Easy-to-install liquid level alarm panel with auto-reset , battery backup, and 120 VAC pump receptacle for indoor use.

PRICING/ORDERING INFORMATION

Suggested List Price

$215.25

Part #

1017385

Description

TAABP-01H (120 VAC w/10' factory-spliced SJE MilliAmpMasterTMcontrol switches)

Shipping Weight

3.66 lbs.

H = High Level

ALARM SYSTEMS SYSTEMS ALARM

MASTER CARTON holds 12 boxed units.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 50/60 Hz, 2.4 watts max. Secondary: 9 VDC BATTERY BACKUP POWER: 9 VDC ALARM PANEL ENCLOSURE: 6 x 4 x 2.25 inches (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic ALARM HORN: 87 decibles at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: for float switch connection only (voltage across terminals is 8-9 VDC) CONTROL SWITCHES: two factory-spliced SJE MilliAmpMasterTM control switches with mounting clamps CABLE: 10 feet (3 meters), flexible 18 gauge, 3 conductor (UL) SJOW, water resistant (CPE) FLOATS: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 140oF (60oC) PUMP CONTROL: 120 VAC, 60 Hz, 13.8 amp max. NEMA 5-15R receptacle

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

62

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1017738F © SJE-Rhombus Printed in USA 11/07

TANK ALERT® ABW Alarm System

Easy-to-install wireless liquid level alarm system with auto-reset and battery backup features. The Tank Alert® ABW alarm system features a battery operated wireless transmitter that is placed in a tank (up to 150 feet away from the indoor alarm). When the high water alarm float switch activates, the transmitter sends a signal and sounds the indoor alarm warning of a potentially threatening liquid level condition. The horn can be silenced, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. The Tank Alert® ABW alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, effluent filters, and other water applications.

Shown with optional mounting bracket.

ALARM SYSTEMS

TANK ALERT ABW ALARM FEATURES

Q NEMA 1 enclosure rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch. Q 6 foot (1.8 meter) power cord. Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q If primary power fails, the alarm system continues to work due to battery backup feature. Battery Backup Power: 9 VDC. (Battery not included.) Q Package includes standard internally weighted Sensor Float® control switch with 10 feet (3.04 meters) of cable with transmitter. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Low battery chirp. Q Loss of signal alarm. After 3 hours and 15 minutes without a signal, an alarm sounds and the red light blinks. Q External terminal block for an optional local alarm float. Q Three-year limited warranty.

®

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inch (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic. ALARM HORN: 87 decibels at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) OPTIONALFLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power (voltage across terminals is 8-9 VDC). FCC ID #: SCP TAABW01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

TANK ALERT® ABW TRANSMITTER FEATURES

Q Wireless transmitter with up to 150 foot range. Q Meets all FCC requirements. Q Long life lithium battery (recommended replacement 2 years). Q Transmitter transmits once per hour or when the float position is changed.

Q This device may not cause harmful interference. Q This device must accept any interference received, including interference that may cause undesired operation.

OPTIONS

Q Mounting bracket Q Alternate float switch models and configurations Q Valve box Q UL Listed component model available

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

63

TANK ALERT® ABW Alarm System

Easy-to-install wireless liquid level alarm system with auto-reset and battery backup features.

PRICING/ORDERING INFORMATION STANDARD MODELS WITHOUT MOUNTING BRACKET

Part #

1017085 1016123 1016124

Description

TA ABW-01H (120 VAC High w/10ft SJE MilliAmpMasterTM pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float internal weight N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® cable weight N.O)

® ®

Suggested List Price

$311.85 $315.00 $315.00 $315.00

Shipping Weight

4 lbs. 4 lbs. 4 lbs. 4 lbs.

ALARM SYSTEMS

1016125

STANDARD MODELS WITH MOUNTING BRACKET

Part #

1017797 1016316 1016317 1017796

Description

TA ABW-01H (120 VAC High w/10ft SJE MilliAmpMasterTM pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float internal weight N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® pipe clamp N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float® cable weight N.O.)

®

Suggested List Price

$343.35 $346.50 $346.50 $346.50

Shipping Weight

5 lbs. 5 lbs. 5 lbs. 5 lbs.

STANDARD MODELS WITH VALVE BOX

Part #

1018345 1018344

Description

TA ABW-01H (120 VAC High w/10ft SJE MilliAmpMasterTM cable weight N.O.) TA ABW-01H (120 VAC High w/10ft Sensor Float internal weight N.O.)

®

Suggested List Price

$343.35 $346.50

Shipping Weight

5 lbs. 5 lbs.

UL Listed component version, Vertical Reed Switch version, and normally closed versions also available. Please contact an SJE-Rhombus® Customer Service Representative for details. H = High Level

MASTER CARTON holds 5 boxed units. Part #

1016291

Description

Replacement 3.6V Lithium Battery

Suggested List Price

$18.90

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) BATTERY BACKUP POWER: 9 VDC ALARM ENCLOSURE: 6 x 4 x 2.25 inches (15.24 x 10.16 x 5.71 cm), NEMA 1 plastic ALARM HORN: 87 decibles at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) OPTIONAL FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only (voltage across terminals is 8-9 VDC)

FCC ID #: SCP TAABW01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

Q This device may not cause harmful interference. Q This device must accept any interference received, including interference that may cause undesired operation.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

64

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1016523G © SJE-Rhombus Printed in USA 11/07

TANK ALERT® I Alarm System

Easy-to-install liquid level alarm system for indoor use. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® I alarm system can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the warning light remains on until the condition is remedied. A green "power on" light indicates power to the alarm panel.

ALARM SYSTEMS

FEATURES

Q NEMA 1 enclosure, designed for ease of installation, rated for indoor use. Q Red "alarm" light, green "power on" light, alarm "test" switch, and horn "silence" switch. Q Alarm horn sounds at 86 decibels at 10 feet (3 meters). Q Can be used with any UL Listed / Recognized switching mechanism rated to include 1 amp, 12 VAC load. Q Alarm system (when installed on separate circuit) operates even if the pump circuit fails. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q UL Listed. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 50/60 Hz, 5 watts max. (alarm condition) Secondary: 12 VAC VOLTAGE FOR 230 VAC MODEL: (not UL Listed or CSA Certified) Primary: 230 VAC, 50/60 Hz, 5 watts max. (alarm condition) Secondary: 12 VAC ALARM ENCLOSURE: 6 x 4 x 2.5 inch (15.24 x 10.16 x 6.35 cm), NEMA 1 metal ALARM HORN: 86 decibels at 10 feet (3 meters) POWER CORD: 6 foot (1.8 meter) FLOAT SWITCH CONNECTION TERMINAL: For float switch connection only. Do not apply power. (Voltage across terminals is 12 VAC. Maximum line impedance for initiating device: 5 ohms). FLOAT SWITCH: Sensor Float® control switch with mounting clamp Cable: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) Switch: hermetically sealed steel capsule features mercury-to-mercury contacts

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q 120 VAC primary voltage or 230 VAC primary voltage (230 VAC model is not UL Listed or CSA Certified).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

65

TANK ALERT® I Alarm System

Easy-to-install liquid level alarm system for indoor use.

PRICING/ORDERING INFORMATION 120 VAC

Part #

1003104 1003365 1002235

Description

101-01H (120 VAC high level) 101-01L (120 VAC low level) 101-01X (120 VAC no float) 101-01H (120 VAC SJE SignalMaster high level) 101-01HSPKT (120 VAC high level with splice kit)

®

Suggested List Price

$115.32 $115.32 $80.54 $111.59 $117.73

Shipping Weight

3.58 lbs. 3.58 lbs. 2.14 lbs. 3.58 lbs. 3.58 lbs.

OPTIONS

CONTROL SWITCH OPTIONS The Tank Alert® I alarm system comes standard with a 15 foot Sensor Float® control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with "no float" to the price of the float switch.

UL Listed for Water & Sewage

ALARM SYSTEMS

1007457 1009207

230 VAC

Part #

1003364 1005420 1005419 1008009

Description

101-02H (230 VAC high level) 101-02L (230 VAC low level) 101-02X (230 VAC no float) 101-02H(230 VAC SJE SignalMaster® high level)

Suggested List Price

$159.98 $159.98 $125.19 $156.24

Shipping Weight

3.58 lbs. 3.58 lbs. 2.14 lbs. 3.58 lbs.

H = High Level L = Low Level X = No Float SPKT = Splice Kit

MASTER CARTON holds 16 boxed units.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: Primary: 120 VAC, 50/60 Hz, 5 watts max. (alarm condition) Secondary: 12 VAC VOLTAGE FOR 230 VAC MODEL: (not UL Listed or CSA Certified) Primary: 230 VAC, 50/60 Hz, 5 watts max. (alarm condition) Secondary: 12 VAC ALARM ENCLOSURE: 6 x 4 x 2.5 inches (15.24 x 10.16 x 6.35 cm), NEMA 1 metal ALARM HORN: 86 decibels at 10 feet (3 meters) POWER CORD: 6 feet (1.8 meters) FLOAT SWITCH CONNECTION TERMINAL: for float switch connection only. Do not apply power. Voltage across terminals is 12 VAC FLOAT SWITCH: Sensor Float® control switch with mounting clamp CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water resistant (CPE) FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) SWITCH: hermetically sealed steel capsule features mercury-tomercury contacts

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

66

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012517G © SJE-Rhombus Printed in USA 11/07

TANK ALERT® XT Alarm System

Versatile, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs. A "power on" light on the switch indicates power to the alarm panel.

ALARM SYSTEMS

FEATURES

Q Enclosure meets Type 3R water-tight standard. Q Automatic alarm reset, horn silence switch, and alarm test switch. Q Alarm horn sounds at 85 decibels at 10 feet (3 meters). Q Alarm system (when installed on separate circuit) operates even if pump circuit fails. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q UL Listed for indoor or outdoor use. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

VOLTAGE: 120 VAC, 50/60 Hz, 8.5 watts max. (alarm condition) ALARM ENCLOSURE: 6.5 x 4.5 x 3.0 inch (16.51 x 11.43 x 7.62 cm), indooroutdoor, weatherproof, thermoplastic meets Type 3R water-tight standard ALARM HORN: 85 decibels at 10 feet (3 meters), meets Type 3R water-tight standard as installed by factory ALARM BEACON: meets Type 3R water-tight standard as installed by factory TEST/SILENCE SWITCH: certified to IP66 and IP68 standards AUXILIARY ALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max., 50/60 Hz PRE-MOUNTED TERMINAL BLOCK (OPTIONAL): 20 amps, 120/230 VAC

OPTIONS

When ordered with the alarm, the system is available with:

POWER CORD (OPTIONAL): 6 foot (1.8 meter) cord with 120 VAC plug FLOAT SWITCH: Sensor Float® control switch with mounting clamp Cable: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, waterresistant (CPE) Float: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) Switch: hermetically sealed steel capsule features mercury-to-mercury contacts. Maximum line impedance for initiating device: 100 ohms

Q alternate float switch models for high or low liquid level warning. Q auxiliary dry normally open contacts for easy attachment of remote devices. Q premounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump power. Meets NEC standard for junction boxes. Q 6 foot (1.8 meter) power cord and liquid-tight connectors.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

67

TANK ALERT® XT Alarm System

Versatile indoor or outdoor liquid level alarm system.

PRICING/ORDERING INFORMATION STANDARD ALARM (120 VAC)

Part #

1004442 1005140 1005141

Description

TAXT-01H (120 VAC High Level) TAXT-01L (120 VAC Low Level) TAXT-01X (120 VAC no float) TAXT-01H (120 VAC High level w/15' SJE SignalMaster ) TAXT- 01L (120 VAC Low level w/15' SJE SignalMaster®)

®

Suggested List Price

$168.64 $168.64 $132.55 $164.69 $164.69

Shipping Weight

3.00 lbs. 3.00 lbs. 1.50 lbs. 3.00 lbs. 3.00 lbs.

OPTIONS

CONTROL SWITCH OPTIONS The Tank Alert® XT alarm system comes standard with a 15 foot Sensor Float® control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with "no float" to the price of the float switch.

UL Listed for Water & Sewage

ALARM SYSTEMS

1009923 1010251

STANDARD ALARM (120 VAC) with terminal block

Part #

1005481 1005835 1005836 1009214 1012416

Description

TAXT-01HTB (120 VAC High Level TB) TAXT-01LTB (120 VAC Low Level TB) TAXT-01XTB (120 VAC no float TB) TAXT-01HAUXTB (120 VAC High Level Auxiliary Contacts TB) TAXT-01HAUXTB (120 VAC High Level Auxiliary Contacts TB w/15' SJE SignalMaster®)

Suggested List Price

$173.46 $173.46 $137.35 $215.46 $211.49

Shipping Weight

3.50 lbs. 3.50 lbs. 2.00 lbs. 3.50 lbs. 3.50 lbs.

STANDARD ALARM (120 VAC) with options

Part #

1006850 1006690

Description

TAXT-01HAUX (120 VAC High Level Auxiliary Contacts) TAXT-01HPC (120 VAC High Level Power Cord)

Suggested List Price

$210.64 $191.74

Shipping Weight

3.50 lbs. 3.50 lbs.

H = High Level L = Low Level X = No Float TB = Includes Terminal Block PC = Power Cord AUX = Auxiliary Contacts

MASTER CARTON holds 12 boxed units.

SPECIFICATIONS

VOLTAGE: 120 VAC, 50/60 Hz, 8.5 watts max. (alarm condition) ALARM ENCLOSURE: 6.5 x 4.5 x 3 inches (16.51 x 11.43 x 7.62 cm), indooroutdoor, weatherproof, thermoplastic, meets Type 3R water-tight standard ALARM HORN: 85 decibles at 10 feet (3 meters), meets Type 3R water-tight standard as installed by factory ALARM BEACON: meets Type 3R standard as installed by factory TEST/SILENCE SWITCH: certified to IP66 and IP68 standards AUXILIARY ALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max., 50/60 HZ PRE-MOUNTED TERMINAL BLOCK (OPTIONAL): 20 amps, 120/230 VAC POWER CORD: (optional) 6 foot (1.8 meters) cord with 120 VAC plug FLOAT SWITCH: Sensor Float® control switch with mounting clamp CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water resistant (CPE) FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) SWITCH: hermetically sealed steel capsule features mercury-to-mercury contacts

OTHER INFORMATION

Option Description Price

A UX PC

Auxiliary Alarm Contacts (installed) 6 foot power cord with two RCC8 1/2 inch liquid-tight connectors

$42.00 $23.10

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

68

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1016796F © SJE-Rhombus Printed in USA 11/07

TANK ALERT® DUO Alarm System

Versatile, indoor or outdoor dual liquid level alarm system. This alarm system monitors two liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® Duo indoor/outdoor alarm monitors two alarm conditions. The alarm horn and red beacon activate in "flashing" mode when a high water condition occurs. The alarm horn and red beacon activate in "constant on" mode for alarm 2.

ALARM SYSTEMS SYSTEMS ALARM

FEATURES

Q Enclosure meets Type 3R water-tight standard. Q Manual alarm reset, horn silence switch, and alarm test switch. Q Alarm horn sounds at 82 decibels at 10 feet (3 meters). Q High water alarm float included. Q High water alarm operates in "flashing" mode when high water condition occurs. Q Alarm 2 input for optional float. (This activates "constant on" alarm mode. Q Alarm system (when installed on separate circuit) operates even if pump circuit fails. Q Complete package includes standard SJE SignalMaster® control switch (high water alarm float) with 15 feet (4.57 meters) of cable and mounting clamp. Q CSA certified. Q Three-year limited warranty.

SPECIFICATIONS

VOLTAGE: 120 VAC, 50/60 Hz, 7 watts max. (alarm condition) ALARM ENCLOSURE: 6.5 x 4.5 x 3.0 inch (16.51 x 11.43 x 7.62 cm), indoor-outdoor, weatherproof, thermoplastic meets Type 3R water-tight standard ALARM HORN: 82 decibels at 10 feet (3 meters), meets Type 3R water-tight standard as installed by factory ALARM BEACON: meets Type 3R water-tight standard as installed by factory TEST/SILENCE SWITCH: water shedding FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp Cable: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, waterresistant (CPE) Float: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and non-potable water up to 140oF (60oC) Maximum Water Depth: 30 feet (9 meters), 13 psi Electrical: 5 amps, 125 VAC/250 VAC, 50/60 Hz

ALARM 2 FLOAT AVAILABLE OPTIONS

Q Vertical Reed Switch Q SJE SignalMaster® control switch Q Sensor Float® control switch Q Sensor Float® Mini control switch Q Call factory for switch compatibility

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

69

TANK ALERT® DUO Alarm System

Versatile, indoor or outdoor dual liquid level alarm system.

PRICING/ORDERING INFORMATION

Suggested List Price

$162.00

Part #

1019947

Description

TADUO-01H (120 VAC w/15ft SJE SignalMaster® control switch)

Shipping Weight

3.66 lbs.

H = High Level

ALARM SYSTEMS SYSTEMS ALARM

MASTER CARTON holds 12 boxed units.

ALARM 2 FLOAT AVAILABLE OPTIONS

Q Vertical Reed Switch Q SJE SignalMaster® control switch Q Sensor Float® control switch Q Sensor Float® Mini control switch Q Call factory for switch compatibility

SPECIFICATIONS

VOLTAGE: 120 VAC, 50/60 Hz, 7 watts max. (alarm condition) ALARM ENCLOSURE: 6.5 x 4.5 x 3.0 inch (16.51 x 11.43 x 7.62 cm), indooroutdoor, weatherproof, thermoplastic meets Type 3R water-tight standard ALARM HORN: 82 decibels at 10 feet (3 meters), meets Type 3R water-tight standard as installed by factory ALARM BEACON: meets Type 3R water-tight standard as installed by factory TEST/SILENCE SWITCH: water shedding FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high impact, corrosion resistant polypropylene housing for use in sewage and non-potable water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 5 amps, 125 VAC/250 VAC, 50/60 Hz

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

70

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1021767B © SJE-Rhombus Printed in USA 11/07

TANK ALERT® 4X Alarm System

Easy-to-install liquid level alarm system which has a NEMA 4X enclosure for indoor or outdoor use. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® 4X alarm system can serve as a high or low level alarm depending on the float switch model used. The stainless steel alarm horn sounds and red beacon illuminates when a potentially threatening liquid level condition occurs.

ALARM SYSTEMS

FEATURES

Q NEMA 4X enclosure rated for indoor or outdoor use. Q Automatic alarm reset and alarm test/normal/silence switch. Q Alarm system (when installed on separate circuit) operates even if the pump circuit fails. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q UL/CUL Listed. Q Three-year limited warranty.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: 120 VAC, 50/60 Hz ALARM ENCLOSURE: 6.4 x 5.3 x 5 inch (16.2 x 13.5 x 13.34 cm), NEMA 4X, indoor-outdoor, weatherproof, UV stabilized thermoplastic ALARM HORN: 88 decibels at 10 feet (3 meters) ALARM BEACON: meets Type 3R standard as installed by factory AUXILIARY ALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max., 50/60 Hz FLOAT SWITCH: Sensor Float® control switch with mounting clamp Cable: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, waterresistant (CPE) Float: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) Switch: hermetically sealed steel capsule features mercury-to-mercury contacts

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q auxiliary dry contacts (normally open and normally closed) for easy attachment of remote devices.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

71

TANK ALERT® 4X Alarm System

Easy-to-install liquid level alarm system which has a NEMA 4X enclosure for indoor or outdoor use.

PRICING/ORDERING INFORMATION 120 VAC

Part #

1008023 1008025 1008027 1008024 1008026

Description

4X-01H (120 VAC High) 4X-01L (120 VAC Low) 4X-01X (120 VAC no float) 4X-01HSGM (120 VAC w/15' SJE SignalMaster High) 4X-01LSGM (120 VAC w/15' SJE SignalMaster Low)

® ®

Suggested List Price

$279.26 $279.26 $246.76 $276.86 $276.86

Shipping Weight

3.65 lbs. 3.65 lbs. 2.1 lbs. 3.4 lbs. 3.4 lbs.

OPTIONS

CONTROL SWITCH OPTIONS The Tank Alert® 4X alarm system comes standard with a 15 foot Sensor Float® control switch with mounting clamp. Other float switches are available. See control switch section of the catalog. To determine the price of alarm with an alternate float, add the price of the part number with "no float" to the price of the float switch.

UL Listed for Water & Sewage

ALARM SYSTEMS

H = High Level L = Low Level X = No Float

MASTER CARTON holds 5 boxed units.

SPECIFICATIONS

VOLTAGE FOR 120 VAC MODEL: 120 VAC, 50/60 Hz ALARM ENCLOSURE: 6.4 x 5.3 x 5 inches (16.2 x 13.5 x 13.34 cm), NEMA 4X, indoor-outdoor, weatherproof, UV stabilized thermoplastic ALARM HORN: 88 decibles at 10 feet (3 meters) ALARM BEACON: meets Type 3R standard as installed by factory AUXILIARY ALARM CONTACTS (OPTIONAL): 120 VAC, 5 amps max., 50/60 HZ FLOAT SWITCH: Sensor Float® control switch with mounting clamp CABLE: 15 feet (4.57 meters), flexible 18 gauge, 2 conductor (UL) SJOW, water resistant (CPE) FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) SWITCH: hermetically sealed steel capsule features mercury-tomercury contacts

OTHER INFORMATION

Option Description

AUX

Price

Auxiliary Alarm Contacts $15.75

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

72

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011939G © SJE-Rhombus Printed in USA 11/07

SJE PUMPMASTER® Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. This mechanically-activated, wide-angle pump switch provides automatic control of pumps in: Q potable water Q water Q sewage applications The SJE PumpMaster® pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications.

U.S. Patent Nos. 5,087,801 & 5,142,108

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Heavy-duty contacts. Q Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. Q Adjustable pumping range of 7 to 36 inches (18 to 91 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 x 9.04 cm) high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 1/2 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 1 HP or less Note: This switch must be used with pumps that provide integral thermal overload protection.

PUMP SWITCHES

(MECHANICAL)

Pump Down / ON position

contacts CLOSED

Pump Down / OFF position

contacts OPEN

on/off ramp

steel ball

steel ball

on/off ramp

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring in 120 VAC or 230 VAC applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

73

SJE PUMPMASTER® Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1002630 1002714 1002712 1002715 1002717 1002719 1002727 1002729 1002731 1002739 1002741 1002743

(MECHANICAL)

PUMP UP

Part #

1002707 1002709 1002706 1002721 1002723 1002725 1002733 1002735 1002737 1002745 1002747 1002749

Description

10PMD1WP 10PMD2WP 10PMDWOP 15PMD1WP 15PMD2WP 15PMDWOP 20PMD1WP 20PMD2WP 20PMDWOP 30PMD1WP 30PMD2WP 30PMDWOP

Description

10PMU1WP 10PMU2WP 10PMUWOP 15PMU1WP 15PMU2WP 15PMUWOP 20PMU1WP 20PMU2WP 20PMUWOP 30PMU1WP 30PMU2WP 30PMUWOP

Suggested List Price

$51.41 $53.20 $45.14 $54.17 $55.98 $47.90 $57.07 $58.75 $50.68 $62.96 $64.75 $56.70

Shipping Weight

1.64 lbs. 1.68 lbs. 1.56 lbs. 1.89 lbs. 1.93 lbs. 1.82 lbs. 2.28 lbs. 2.32 lbs. 2.20 lbs. 2.94 lbs. 2.99 lbs. 2.86 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. CABLE WEIGHT MOUNTING Is also available. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

PUMP SWITCHES

D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

LR54245

SPECIFICATIONS

PUMPING RANGE: 7 to 36 inches (18 cm to 91 cm) CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 cm x 9.04 cm), high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying in potable water, water, and sewage applications. PUMP UP is normally closed contacts for filling in potable water, water, and sewage applications. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

13 amps 13 amps

85 amps 85 amps

1/2 HP or less 1 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

74

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011927H © SJE-Rhombus Printed in USA 11/07

SJE PUMPMASTER® PLUS Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC. This mechanically-activated, wide-angle pump switch provides automatic control of pumps in: Q potable water Q water Q sewage applications The SJE PumpMaster® Plus pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications.

U.S. Patent Nos. 5,087,801 & 5,142,108

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Heavy-duty contacts. Q Controls pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC. Q Adjustable pumping range of 7 to 36 inches (18 to 91 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 x 9.04 cm) high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 15 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 3/4 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 15 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 2 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection.

PUMP SWITCHES

(MECHANICAL)

Pump Down / ON position

contacts CLOSED

Pump Down / OFF position

contacts OPEN

on/off ramp

steel ball

steel ball

on/off ramp

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring in 120 VAC or 230 VAC applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

75

SJE PUMPMASTER® PLUS Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1003232 1003233 1003235 1003243 1003245 1003247 1003255 1003257 1003259 1003267 1003269 1003271

(MECHANICAL)

PUMP UP

Part #

1003237 1003239 1003241 1003249 1003251 1003253 1003261 1003263 1003265 1003273 1003275 1003277

Description

10PMPD1WP 10PMPD2WP 10PMPDWOP 15PMPD1WP 15PMPD2WP 15PMPDWOP 20PMPD1WP 20PMPD2WP 20PMPDWOP 30PMPD1WP 30PMPD2WP 30PMPDWOP

Description

10PMPU1WP 10PMPU2WP 10PMPUWOP 15PMPU1WP 15PMPU2WP 15PMPUWOP 20PMPU1WP 20PMPU2WP 20PMPUWOP 30PMPU1WP 30PMPU2WP 30PMPUWOP

Suggested List Price

$69.22 $71.02 $62.96 $72.22 $74.04 $65.97 $75.24 $77.04 $68.99 $81.85 $83.66 $75.60

Shipping Weight

1.88 lbs. 1.92 lbs. 1.73 lbs. 2.23 lbs. 2.23 lbs. 2.13 lbs. 2.57 lbs. 2.61 lbs. 2.49 lbs. 3.38 lbs. 3.41 lbs. 3.30 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. CABLE WEIGHT MOUNTING Is also available. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

PUMP SWITCHES

D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

LR54245

SPECIFICATIONS

PUMPING RANGE: 7 to 36 inches (18 cm to 91 cm) CABLE: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 cm x 9.04 cm), high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying in potable water, water, or sewage applications. PUMP UP is normally closed contacts for filling in potable water, water, or sewage applications. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

15 amps 15 amps

85 amps 85 amps

3/4 HP or less 2 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

76

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011928H © SJE-Rhombus Printed in USA 11/07

SJE PUMPMASTER® SPDT Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. This mechanically-activated, wide-angle pump switch provides automatic control of pumps in: Q potable water Q water Q sewage applications It can be wired to work in either pump down (normally open) or pump up (normally closed) applications. The SJE PumpMaster® SPDT pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications.

U.S. Patent Nos. 5,087,801 & 5,142,108

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Can be wired to work in either pump down (normally open) or pump up (normally closed) applications (Single Pole, Double Throw). Q Heavy-duty contacts. Q Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. Q For direct wiring in 120 or 230 VAC applications. Q Adjustable pumping range of 7 to 36 inches (18 to 91 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 16 gauge, 3 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 x 9.04 cm) high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 1/2 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 85 amps Recommended Pump HP: 1 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection.

PUMP SWITCHES

(MECHANICAL)

Pump Down / ON position

contacts CLOSED

Pump Down / OFF position

contacts OPEN

on/off ramp

steel ball

steel ball

on/off ramp

OPTIONS

This switch is available:

Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

77

SJE PUMPMASTER® SPDT Pump Switch

Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN OR PUMP UP

Part Number

1004834 1004835 1004836 1004837 1004838 1004839 1004840 1004841 without plug only

Description

10PMSPDTPC 10PMSPDTWE 15PMSPDTPC 15PMSPDTWE 20PMSPDTPC 20PMSPDTWE 30PMSPDTPC 30PMSPDTWE

Suggested List Price

$50.07 $56.70 $53.21 $59.70 $56.09 $62.72 $59.10 $69.50

Shipping Weight

1.81 lbs. 3.65 lbs. 2.21 lbs. 4.05 lbs. 2.61 lbs. 4.45 lbs. 3.41 lbs. 5.25 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. Cable weight mounting is also available. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

PUMP SWITCHES

PC = Pipe Clamp WE = Weighted Externally Can be wired to work in either pump down (normally open) or pump up (normally closed) applications (Single Pole, Double Throw). NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

(MECHANICAL)

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

LR54245

SPECIFICATIONS

PUMPING RANGE: 7 to 36 inches (18 cm to 91 cm) CABLE: flexible 16 gauge, 3 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 cm x 9.04 cm), high impact, corrosion resistant, PVC housing for use in sewage and water up to 140oF (60oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying in potable water, water or sewage applications. PUMP UP is normally closed contacts for filling in potable water, water or sewage applications. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

13 amps 13 amps

85 amps 85 amps

1/2 HP or less 1 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

78

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011929H © SJE-Rhombus Printed in USA 11/07

DOUBLE FLOAT MASTER Pump Switch

®

Mechanically activated, wide-angle switch designed to control pumps up to 13 FLA, 78 LRA, 120 VAC or 240 VAC. This mechanically activated, wide-angle pump switch provides automatic control of pumps in non-potable water and sewage applications. It is well-suited for confined applications requiring an accurate pumping range. It is not sensitive to rotation or turbulence. This switch is voltage sensitive - use with correct voltage. The Double Float® Master pump switch consists of two mechanical floats and a splice tube. The splice tube contains a holding relay which enables the floats to function in series. The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float® Master pump switch to operate relay control panels for larger pump applications.

Patent Pending

FEATURES

Q Controls pumps up to 13 FLA, 78 LRA, 120 VAC or 240 VAC. Q Adjustable pumping range of 10 to 56 inches (25.4 to 142.2 cm) with increased pumping range up to 6 feet (1.8 meters) available. Q Includes standard mounting clamps and boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

Cable attached to float housing: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) Cable above splice: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, waterresistant, thermoplastic FLOATS: 2.74 inch diameter x 4.83 inch long (7.0 x 12.3 cm) high impact, corrosion resistant, PP housing for use in sewage and non-potable water up to 140oF (60oC) ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current (FLA): 13 amps Maximum Pump Starting Current (LRA): 78 amps

4"

PUMP SWITCHES

(MECHANICAL)

Pump Down Schematic

4"

240 VAC 50/60Hz Single Phase: Maximum Pump Running Current (FLA): 13 amps Maximum Pump Starting Current (LRA): 78 amps

deactivation point (approximately 4 inches below mounting)

NOTE: This switch must be used with pumps that provide integral thermal overload protection.

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 240 VAC piggy-back plug. Q without a plug for direct wiring (120 VAC units can only be used with 120 VAC applications within specified amp ratings. 240 VAC units can only be used with 240 VAC applications within specified amp ratings). Q in standard cable lengths of 15, 20, or 30 feet and 5 or 10 meters (longer lengths available).

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

Double Float® pump switch is a registered trademark of SJE-Rhombus® Controls.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

79

DOUBLE FLOAT MASTER Pump Switch

®

Mechanically activated, wide-angle switch designed to control pumps up to 13 FLA, 78 LRA, 120 VAC or 240 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1016864 1017657 1017658 1017659 1017660 1017661 1017662 1017663

PUMP UP

Part #

1017668 1017669 1017670 1017671 1017672 1017673 1017674 1017675

Description

15DFMMD1WP 15DFMMD2WP 15DFMMD1WOP 15DFMMD2WOP 20DFMMD1WP 20DFMMD2WP 20DFMMD1WOP 20DFMMD2WOP

Description

15DFMMU1WP 15DFMMU2WP 15DFMMU1WOP 15DFMMU2WOP 20DFMMU1WP 20DFMMU2WP 20DFMMU1WOP 20DFMMU2WOP

Suggested List Price

$112.78 $115.82 $106.11 $108.34 $116.99 $120.03 $110.32 $112.55

Shipping Weight

3.63 lbs. 3.64 lbs. 3.55 lbs. 3.51 lbs. 4.04 lbs. 4.08 lbs. 3.97 lbs. 4.01 lbs.

OPTIONS

PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

1017664 1017665 1017666 1017667

30DFMMD1WP 30DFMMD2WP 30DFMMD1WOP 30DFMMD2WOP

1017676 1017677 1017678 1017679

30DFMMU1WP 30DFMMU2WP 30DFMMU1WOP 30DFMMU2WOP

$125.98 $129.02 $119.44 $121.54

4.95 lbs. 4.99 lbs. 4.86 lbs. 4.87 lbs.

PUMP SWITCHES

LR54245

(MECHANICAL)

D = Pump Down U = Pump Up 1 = 120 VAC 2 = 240 VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30).

SPECIFICATIONS

PUMPING RANGE: 10 to 56 inches (25.4 cm to 142.2 cm), increased pumping range available. Call factory for quote. CABLE ATTACHED TO FLOAT HOUSING: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) CABLE ABOVE SPLICE: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, water-resistant thermoplastic FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant, PP housing for use in sewage and non-potable water up to 140oF (60oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. PUMP UP is normally closed contacts for filling. DIRECT WIRING 120 VAC units used for direct wiring (without plug) can only be used with 120 VAC applications within specified amp ratings. 240 VAC units used for direct wiring (without plug) can only be used with 240 VAC applications within specified amp ratings.

120 VAC 240 VAC

13 amps 13 amps

78 amps 78 amps

NOTE:

This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

80

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1017737G © SJE-Rhombus Printed in USA 11/07

SJE AMPMASTER® Pump Switch

Mechanically-activated, wide-angle, 20 amp rated switch designed for direct control of pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC.

This mechanically-activated, wide-angle, 20 amp rated pump switch provides automatic control of grinder and high head sewage pumps in grinder and lift station applications, as well as septic tank effluent pump (STEP) systems. The SJE AmpMaster® pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. It is available for pump down applications only.

U.S. Patent Nos. 5,087,801 & 5,142,108

FEATURES

Q Maximum pump running current of 20 amps. Q Heavy-duty contacts mounted on high-conductivity copper substrates. Q Controls pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC. Q Second set of non-conductive contacts enhance switch activation. Q For direct wiring in 125 VAC or 250 VAC applications (piggy-back plug model not available). Q Adjustable pumping range of 9 to 24 inches (23 to 61 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 12 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 x 9.04 cm) high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 120oF (50oC) ELECTRICAL: 125 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 20 amps Maximum Pump Starting Current: 120 amps Recommended Pump HP: 1 1/2 HP or less 250 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 20 amps Maximum Pump Starting Current: 120 amps Recommended Pump HP: 3 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection. Certain pump applications may require the use of an external capacitor start kit.

PUMP SWITCHES

(MECHANICAL)

Pump Down / ON position

active contacts CLOSED non-conductive contacts

Pump Down / OFF position

active contacts OPEN non-conductive contacts

on/off ramp steel ball steel ball on/off ramp

OPTIONS

This switch is available:

Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

81

SJE AMPMASTER® Pump Switch

Mechanically-activated, wide-angle, 20 amp rated switch designed for direct control of pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN ONLY

Part Number

1006310 1006311 1006312 1006313 without plug only

Description

10AMDWOP 15AMDWOP 20AMDWOP 30AMDWOP

Suggested List Price

$90.28 $94.49 $98.70 $107.74

Shipping Weight

1.79 lbs. 2.27 lbs. 2.72 lbs. 3.12 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 90¢ per foot (list price).

D = Pump Down WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

PUMP SWITCHES

(MECHANICAL)

UL Recognized for Water & Sewage

LR54245

SPECIFICATIONS

PUMPING RANGE: 9 to 24 inches (23 cm to 61 cm) CABLE: flexible 12 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.05 inch diameter x 3.56 inch long (7.75 cm x 9.04 cm), high impact, corrosion resistant, PVC housing for use in sewage and nonpotable water up to 120oF (50oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. Available in pump down version only. DIRECT WIRING Units may be used with either 125 VAC or 250 VAC applications within specified amp ratings.

125 VAC 250 VAC

20 amps 20 amps

120 amps 120 amps

1 1/2 HP or less 3 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection. Certain pump applications may require the use of an external capacitor start kit.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

82

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011932J © SJE-Rhombus Printed in USA 11/07

SJE VERTICALMASTER® Pump Switch

Mechanically-activated switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. This mechanically-activated pump switch is designed to operate in non-potable water and sewage applications with limited space. It works well in small sump chambers, effluent applications, and laundry trays, as well as in large tanks. The SJE VerticalMaster® pump switch is not sensitive to turbulence. It is available for pump down applications only.

U.S. Patent No. 5,155,311 Canadian Patent No. 2,060,748

FEATURES

Q Heavy-duty contacts. Q Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. Q Adjustable pumping range of .75 to 6.5 inches (2 to 17 cm). Q Includes standard boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW or SJTOW, water-resistant (CPE) MOUNTING BRACKET & HOSE CLAMP: stainless steel LIFT ROD: injection molded acetal plastic FLOAT STOP: neoprene SWITCH AND FLOAT HOUSING: high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 125oF (52oC)

(MECHANICAL)

PUMP SWITCHES

Pump Down / ON position

Pump Down / OFF position

overall dimensions: 12 inch high x 5 inch x 3 inch wide (30.5 cm high x 12.7 cm x 7.6 cm wide) switch housing dimensions (excluding cable entrance): 2 inch high x 2.8 inch wide (5 cm high x 7.1 cm wide) float housing dimensions: 2.3 inch high x 2.7 inch wide (5.8 cm high x 6.9 cm wide)

contacts closed

yoke

contacts open

yoke

ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 60 amps Recommended Pump HP: 1/2 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 12 amps Maximum Pump Starting Current: 60 amps Recommended Pump HP: 1 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection.

OPTIONS

This switch is available:

Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring in 120 VAC or 230 VAC applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

83

SJE VERTICALMASTER® Pump Switch

Mechanically-activated pump switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN ONLY

Part Number

1003590 1003772 1003776 1003769 1003773 1003777 1003770 1003774 1003778 1003771 1003775

Description

10VM1WP 10VM2WP 10VMWOP 15VM1WP 15VM2WP 15VMWOP 20VM1WP 20VM2WP 20VMWOP 30VM1WP 30VM2WP 30VMWOP

Suggested List Price

$53.09 $54.89 $46.83 $55.85 $57.67 $49.59 $58.62 $60.43 $49.59 $64.64 $66.44 $58.39

Shipping Weight

1.73 lbs. 1.77 lbs. 1.65 lbs. 2.08 lbs. 2.12 lbs. 2.00 lbs. 2.43 lbs. 2.47 lbs. 2.35 lbs. 3.13 lbs. 3.17 lbs. 3.05 lbs.

OPTIONS

MOUNTING BRACKET AND HOSE CLAMP are standard. PACKAGING Boxed - Standard. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recongnized for Water & Sewage

PUMP SWITCHES

1003779

(MECHANICAL)

LR54245

1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

SPECIFICATIONS

PUMPING RANGE: 0.75 to 6.5 inches (2 cm to 17 cm) CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW or SJTOW, water-resistant (CPE). MOUNTING BRACKET AND CLAMP: stainless steel LIFT ROD: injection molded acetal plastic FLOAT STOP: neoprene SWITCH AND FLOAT HOUSING: high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 125oF (52oC)

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

Q Overall dimensions: 12 inch high x 5 inch x 3 inch wide (30.5 cm x 12.7 cm x 7.6 cm) Q Switch housing dimensions: 2 inch high x 2.8 inch diameter (5 cm x 7.1 cm) Q Float housing dimensions: 2.3 inch high x 2.8 inch diameter (5.8 cm x 6.9 cm)

ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

120 VAC 230 VAC

13 amps 12 amps

60 amps 60 amps

1/2 HP or less 1 HP or less

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

84

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011923K © SJE-Rhombus Printed in USA 11/07

SJE MICROMASTER® AC/DC Pump Switch

Mechanically-activated, wide-angle switch designed for performance and dependability. This mechanically-activated, wide-angle pump switch provides automatic control of pumps in: Q Potable water Q Water Q Sewage applications This SJE MicroMaster® AC/DC pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications.

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Mechanically-activated, snap action contacts. Q High impact, corrosion resistant, polypropylene float housing. Q Adjustable pump range of 8 to 36 inches (20 to 91 cm). Q UL Recognized for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant, (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant, polypropylene housing for use in water up to 140oF (60oC) MAXIMUM WATER DEPTH: 33 feet (10 meters) or 13 psi (90 kPa)

PUMP SWITCHES

ELECTRICAL: 12 VDC: Maximum Pump Running Current: 10 amps Maximum Pump Starting Current: 100 amps 125 VAC 50/60Hz Single Phase: Maximum Pump Run Current: 10 amps Maximum Pump Starting Current: 60 amps

(MECHANICAL)

OPTIONS

This switch is available:

Q for pump down or pump applications applications as specified by part number. Q without a plug for direct wiring. Q in standard cable length of 15 feet.

250 VAC 50/60Hz Single Phase: Maximum Pump Run Current: 8 amps Maximum Pump Starting Current: 60 amps NOTE: This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads NOTE: This switch must be used with pumps that provide integral thermal overload protection.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

85

SJE MICROMASTER® AC/DC Pump Switch

Mechanically-activated, wide-angle switch designed for performance and dependability.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1009813

PUMP UP

Part #

1012543

Description

15MMDCDWOP

Description

15MMDCUWOP

Suggested List Price

$41.79

Shipping Weight

3.63 lbs.

OPTIONS

MOUNTING CLAMP is standard. PACKAGING Bulk - Standard

PUMP SWITCHES

(MECHANICAL)

SPECIFICATIONS

PUMPING RANGE: 8 to 36 inches (20 cm to 91 cm). CABLE : flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant, polypropylene housing for use in water up to 140oF (60oC) MAXIMUM WATER DEPTH: 33 feet (10 meters) or 13 psi (90 kPa) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying in potable water, water or sewage applications. PUMP UP is normally closed contacts for filling in potable water, water or sewage applications. DIRECT WIRING Units used for direct wiring (without plug) may be used in 12 VDC, 125 VAC or 250 VAC applications within specified amp ratings.

12 VDC 125 VAC 250 VAC

10 amps 10 amps 8 amps

100 amps 60 amps 60 amps

NOTE: This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads NOTE: This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

86

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011934C © SJE-Rhombus Printed in USA 11/07

JUNIOR SUPER SINGLE® Pump Switch

Mercury activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. This mercury activated, wide-angle pump switch provides automatic control of smaller pumps in non-potable water and sewage applications. Although this switch is not sensitive to rotation, it is affected by turbulence and should be mounted in a non-turbulent location. The Junior Super Single® pump switch is not recommended for use with motor contactors or relays because the motor contactor or relay may experience chattering. A Super Single® or Double Float® pump switch would operate more efficiently in these installations.

U.S. Patent Nos. 4,529,854 & 4,572,934

FEATURES

Q Controls pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC. Q Adjustable pumping range of 6.5 to 19 inches (16.5 to 48 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 2.81 inch diameter x 3.42 inch long (7.14 cm x 8.68 cm), high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MERCURY SWITCH: mercury-to-metal contacts, hermetically sealed in a steel capsule ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 13 amps Maximum Pump Starting Current: 40 amps Recommended Pump HP: 1/2 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 8 amps Maximum Pump Starting Current: 20 amps Recommended Pump HP: 1 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection.

PUMP SWITCHES

(MERCURY)

Pump Down / ON position

contacts CLOSED

Pump Down / OFF position

contacts OPEN

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring in 120 VAC or 230 VAC applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

87

JUNIOR SUPER SINGLE® Pump Switch

Mercury activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1001896 1001914 1001916 1001817 1001926 1001928 1001898 1001937 1001939 1001900 1001948

PUMP UP

Part #

1001918 1001921 1001923 1001930 1001932 1001934 1001941 1001943 1001945 1001952 1001954 1001956

Description

10JSD1WP 10JSD2WP 10JSDWOP 15JSD1WP 15JSD2WP 15JSDWOP 20JSD1WP 20JSD2WP 20JSDWOP 30JSD1WP 30JSD2WP 30JSDWOP

Description

10JSU1WP 10JSU2WP 10JSUWOP 15JSU1WP 15JSU2WP 15JSUWOP 20JSU1WP 20JSU2WP 20JSUWOP 30JSU1WP 30JSU2WP 30JSUWOP

Suggested List Price

$52.97 $54.77 $46.47 $55.73 $57.67 $49.35 $58.62 $60.54 $52.25 $64.89 $66.70 $58.39

Shipping Weight

1.45 lbs. 1.48 lbs. 1.37lbs. 1.77 lbs. 1.81 lbs. 1.68 lbs. 2.11 lbs. 2.14 lbs. 2.03 lbs. 2.82 lbs. 2.86 lbs. 2.74 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

PUMP SWITCHES

1001950

(MERCURY)

D = Pump Down U = Pump Up 1 = 120 VAC 2 = 230 VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

LR54245

SPECIFICATIONS

PUMPING RANGE: 6.5 to 19 inches (16.5 cm to 48 cm) CABLE: flexible 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 2.81 inch diameter x 3.42 inch long (7.14cm x 8.68 cm), high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MERCURY SWITCH: mercury-to-metal contacts, hermetically sealed in a steel capsule ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. PUMP UP is normally closed contacts for filling. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

13 amps 8 amps

40 amps 20 amps

1/2 HP or less 1 HP or less

NOTE: This switch must be used with pumps that provide integral thermal overload protection. This switch is not designed to be directly wired to relays or motor contactors.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753) Fax 218-847-4617

88

www.sjerhombus.com [email protected]

Cat Page PN 1012513G © SJE-Rhombus Printed in USA 11/07

SUPER SINGLE® Pump Switch

Mercury activated, wide-angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. This mercury activated, wide-angle pump switch provides automatic control of pumps in non-potable water and sewage applications. This switch is not sensitive to rotation or turbulence. The Super Single® pump switch is suitable for use with intrinsically safe circuits. Contact SJE-Rhombus regarding specific intrinsically safe applications.

U.S. Patent No. 4,302,641

FEATURES

Q Patented tumbler assembly gives positive pump on or pump off. Q Controls pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. Q Adjustable pumping range of 6.5 to 13.5 inches (17 to 34 cm). Q Includes standard mounting clamp and boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.38 inch diameter x 4.25 inch long (8.58 x 10.80 cm) high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MERCURY SWITCH: mercury-to-mercury contacts, hermetically sealed in a steel capsule

(MERCURY)

PUMP SWITCHES

Pump Down / ON position

contacts CLOSED

Pump Down / OFF position

contacts OPEN

ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 15 amps Maximum Pump Starting Current: 55 amps Recommended Pump HP: 1 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 12 amps Maximum Pump Starting Current: 35 amps Recommended Pump HP: 2 HP or less NOTE: This switch must be used with pumps that provide integral thermal overload protection.

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring in 120 VAC or 230 VAC applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

89

SUPER SINGLE® Pump Switch

Mercury activated, wide-angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1001958 1001961 1001963 1001971 1001973 1001975 1001983 1001985 1001987 1001988 1001996 1001998

(MERCURY)

PUMP UP

Part #

1001965 1001967 1001969 1001977 1001979 1001981 1001989 1001991 1001993 1002000 1002002 1002004

Description

10SSD1WP 10SSD2WP 10SSDWOP 15SSD1WP 15SSD2WP 15SSDWOP 20SSD1WP 20SSD2WP 20SSDWOP 30SSD1WP 30SSD2WP 30SSDWOP

Description

10SSU1WP 10SSU2WP 10SSUWOP 15SSU1WP 15SSU2WP 15SSUWOP 20SSU1WP 20SSU2WP 20SSUWOP 30SSU1WP 30SSU2WP 30SSUWOP

Suggested List Price

$92.09 $94.02 $85.70 $95.21 $97.02 $88.71 $98.11 $99.91 $91.61 $104.85 $106.77 $98.47

Shipping Weight

1.75 lbs. 1.76 lbs. 1.65 lbs. 2.15 lbs. 2.18 lbs. 2.08 lbs. 2.67 lbs. 2.71 lbs. 2.59 lbs. 3.35 lbs. 3.39 lbs. 3.27 lbs.

OPTIONS

MOUNTING CLAMP If mounting clamp is not required, specify and deduct 60¢ from list price. PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot.

PUMP SWITCHES

UL Recognized for Water & Sewage

D = Pump Down U = Pump Up 1 = 120 VAC 2 = 230 VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

LR54245

SPECIFICATIONS

PUMPING RANGE: 6.5 to 13.5 inches (17 cm to 34 cm) CABLE: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 3.38 inch diameter x 4.25 inch long (8.58 cm x 10.80 cm), high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MERCURY SWITCH: mercury-to-mercury contacts, hermetically sealed in a steel capsule ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. PUMP UP is normally closed contacts for filling. DIRECT WIRING Units used for direct wiring (without plug) may be used in either 120 VAC or 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

15 amps 12 amps

55 amps 35 amps

1 HP or less 2 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection. Suitable for use with intrinsically safe circuits. Contact SJE-Rhombus regarding specific intrinsically safe applications.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

90

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012514G © SJE-Rhombus Printed in USA 11/07

DOUBLE FLOAT Pump Switch

®

Mercury activated, wide-angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. This mercury activated, wide-angle pump switch provides automatic control of pumps in nonpotable water and sewage applications. It is well-suited for confined applications requiring an accurate pumping range. It is not sensitive to rotation or turbulence. This switch is voltage sensitive - use with correct voltage. The Double Float® pump switch consists of two floats and a splice tube. Each float contains a heavy-duty mercury switch. The splice tube contains a holding relay which enables the floats to function in series. The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float® pump switch to operate relay control panels for larger pump applications.

Patent Pending

FEATURES

Q Controls pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC. Q Adjustable pumping range of 1.75 to 48 inches (4.45 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available. Q Includes standard mounting clamps and boxed packaging. Q UL Recognized for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

Cable attached to float housing: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) Cable above splice: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, waterresistant, thermoplastic FLOATS: 3.38 inch diameter x 4.55 inch long (8.58 x 11.56 cm) high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MERCURY SWITCH: mercury-to-mercury contacts, hermetically sealed in a steel capsule ELECTRICAL: 120 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 15 amps Maximum Pump Starting Current: 55 amps Recommended Pump HP: 1 HP or less 230 VAC 50/60Hz Single Phase: Maximum Pump Running Current: 12 amps Maximum Pump Starting Current: 35 amps Recommended Pump HP: 2 HP or less

PUMP SWITCHES

(MERCURY)

Pump Down Schematic

OPTIONS

This switch is available:

Q for pump down or pump up applications as specified by part number. Q with a 120 VAC or 230 VAC piggy-back plug. Q without a plug for direct wiring (120 VAC units can only be used with 120 VAC applications within specified amp ratings. 230 VAC units can only be used with 230 VAC applications within specified amp ratings). Q in standard cable lengths of 15, 20, or 30 feet and 5 or 10 meters (longer lengths available).

NOTE: This switch must be used with pumps that provide integral thermal overload protection.

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

Double Float® pump switch is a registered trademark of SJE-Rhombus® Controls.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

91

DOUBLE FLOAT Pump Switch

®

Mercury activated, wide-angle switch designed to control pumps up to 1 HP at 120 VAC and 2 HP at 230 VAC.

PRICING/ORDERING INFORMATION PUMP DOWN

Part #

1002022 1002024 1002026 1002028 1002038 1002040 1002042 1002044

PUMP UP

Part #

1002030 1002032 1002034 1002036 1002046 1002048 1002050 1002052

Description

15DFD1WP 15DFD2WP 15DFD1WOP 15DFD2WOP 20DFD1WP 20DFD2WP 20DFD1WOP 20DFD2WOP

Description

15DFU1WP 15DFU2WP 15DFU1WOP 15DFU2WOP 20DFU1WP 20DFU2WP 20DFU1WOP 20DFU2WOP

Suggested List Price

$116.16 $119.29 $109.29 $111.59 $120.50 $123.63 $113.64 $115.92

Shipping Weight

3.63 lbs. 3.64 lbs. 3.55 lbs. 3.51 lbs. 4.04 lbs. 4.08 lbs. 3.97 lbs. 4.01 lbs.

OPTIONS

PACKAGING Boxed - Standard Bagged - Specify and deduct 40¢ from list price. Bulk - Specify and deduct 60¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Recognized for Water & Sewage

1002054 1002056 1002058 1002060

30DFD1WP 30DFD2WP 30DFD1WOP 30DFD2WOP

1002062 1002064 1002066 1002068

30DFU1WP 30DFU2WP 30DFU1WOP 30DFU2WOP

$129.77 $132.89 $123.02 $125.19

4.95 lbs. 4.99 lbs. 4.86 lbs. 4.87 lbs.

PUMP SWITCHES

LR54245

(MERCURY)

D = Pump Down U = Pump Up 1 = 120 VAC 2 = 230 VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30).

SPECIFICATIONS

PUMPING RANGE: 1.75 to 48 inches (4.45 cm to 122 cm), increased pumping range available. Call factory for quote. CABLE ATTACHED TO FLOAT HOUSING: flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) CABLE ABOVE SPLICE: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, water-resistant thermoplastic FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.5 cm), high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) ELECTRICAL:

Voltage 50Hz/60Hz Single Phase Max. Pump Run Current Max. Pump Start Current Recommended Pump HP

OTHER INFORMATION

PUMP DOWN is normally open contacts for emptying. PUMP UP is normally closed contacts for filling. DIRECT WIRING 120 VAC units used for direct wiring (without plug) can only be used with 120 VAC applications within specified amp ratings. 230 VAC units used for direct wiring (without plug) can only be used with 230 VAC applications within specified amp ratings.

120 VAC 230 VAC

15 amps 12 amps

55 amps 35 amps

1 HP or less 2 HP or less

NOTE:

This switch must be used with pumps that provide integral thermal overload protection.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

92

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012515H © SJE-Rhombus Printed in USA 11/07

SJE SIGNALMASTER® Control Switch

Mechanically-activated, narrow-angle float switch designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in: Q potable water Q water Q sewage applications The SJE SignalMaster® control switch is not sensitive to rotation. Normally Open Model (high level) The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level, and turns off (opens) when the float drops slightly below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the float tips slightly below horizontal signaling a low level, and turns off (opens) when the float tips slightly above horizontal.

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Mechanically-activated, snap action contacts. Q High impact, corrosion resistant, polypropylene float housing. Q Not sensitive to rotation. Q Control differential of 1.5 inches (4 cm) above or below horizontal. Q UL Listed for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 x 12.3 cm) high impact, corrosion resistant, polypropylene housing for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi (90 kPa) ELECTRICAL: 5 amp, 125/250 VAC, 50/60 Hz NOTE: This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads

CONTROL SWITCHES

OPTIONS

(MECHANICAL)

This switch is available:

Q CE certified unit available upon request. Q for normally open (high level) applications or normally closed (low level) applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available) Q with two mounting options that allow for flexibility in installation:

Mounting Clamp: for applications where the switch can be attached to a discharge pipe or similar mounting device. Externally Weighted: for applications where the switch can be suspended from above.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

93

SJE SIGNALMASTER® Control Switch

Mechanically-activated, narrow-angle float switch designed to activate pump control panels and alarms.

PRICING/ORDERING INFORMATION Normally Open

Part #

1006042 1006050 1006043 1006051 1006044 1006052 1006045 1006053

Normally Closed

Part #

1006046 1006054 1006047 1006055 1006048 1006056 1006049 1006057

Description

10SGMPCNO 10SGMWENO 15SGMPCNO 15SGMWENO 20SGMPCNO 20SGMWENO 30SGMPCNO 30SGMWENO

Description

10SGMPCNC 10SGMWENC 15SGMPCNC 15SGMWENC 20SGMPCNC 20SGMWENC 30SGMPCNC 30SGMWENC

Suggested List Price

$29.37 $35.99 $32.14 $38.76 $34.90 $41.54 $40.93 $47.54

Shipping Weight

1.04 lbs. 2.73 lbs. 1.37 lbs. 3.05 lbs. 1.69 lbs. 3.30 lbs. 2.34 lbs. 4.03 lbs.

OPTIONS

MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60¢ from list price. PACKAGING Bagged - Standard. Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20¢ from list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price)

UL Listed for Water & Sewage

PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30)

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

SPECIFICATIONS

CONTROL SWITCHES

CABLE: flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE)

(MECHANICAL)

OTHER INFORMATION

NORMALLY OPEN (high level) OPERATION The control switch closes (turns on) when the float tips slightly above horizontal signaling a high level, and opens (turns off) when the float drops slightly below horizontal in potable water, water or sewage applications. NORMALLY CLOSED (low level) OPERATION The control switch closes (turns on) when the float tips slightly below horizontal signaling a low level, and opens (turns off) when the float tips slightly above horizontal in potable water, water or sewage applications.

FLOAT: 2.74 inch diameter x 4.83 inch long (7 x 12.3 cm), high impact, corrosion resistant polypropylene for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 5 amp, 125/250 VAC, 50/60 Hz This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

94

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011937G © SJE-Rhombus Printed in USA 11/07

SJE SIGNALMASTER® SPDT Control Switch

Mechanically-activated, narrow-angle float switch designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in: Q potable water Q water Q sewage applications The SJE SignalMaster® SPDT control switch can be wired to work in either normally open or normally closed applications. It is not sensitive to rotation. When wired as Normally Open (high level) The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level, and turns off (opens) when the float drops slightly below horizontal. When wired as Normally Closed (low level) The control switch turns on (closes) when the float tips slightly below horizontal signaling a low level, and turns off (opens) when the float tips slightly above horizontal.

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Can be wired to work in either normally open or normally closed applications (Single Pole, Double Throw). Q Mechanically-activated, snap action contacts. Q High impact, corrosion resistant, polypropylene float housing. Q Not sensitive to rotation. Q Control differential of 1.5 inches (4 cm) above or below horizontal. Q UL Listed for use in water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 18 gauge, 3 conductor (UL) SJOW, water-resistant (CPE) FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 x 12.3 cm) high impact, corrosion resistant, polypropylene housing for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi (90 kPa) ELECTRICAL: 5 amp, 125/250 VAC, 50/60 Hz NOTE: This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads

CONTROL SWITCHES

(MECHANICAL)

OPTIONS

This switch is available:

Q CE certified switch available upon request Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available) Q with two mounting options that allow for flexibility in installation:

Mounting Clamp: for applications where the switch can be attached to a discharge pipe or similar mounting device. Externally Weighted: for applications where the switch can be suspended from above.

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

95

SJE SIGNALMASTER® SPDT Control Switch

Mechanically-activated, narrow-angle float switch designed to activate pump control panels and alarms.

PRICING/ORDERING INFORMATION Normally Open or Normally Closed

Part Number

1006094 1006098 1006095 1006099 1006096 1006100 1006097 1006101 PC = Pipe Clamp

Description

10SGMSPDTPC 10SGMSPDTWE 15SGMSPDTPC 15SGMSPDTWE 20SGMSPDTPC 20SGMSPDTWE 30SGMSPDTPC 30SGMSPDTWE

Suggested List Price

$33.59 $40.20 $36.59 $43.22 $39.62 $46.22 $46.22 $52.85

Shipping Weight

1.20 lbs. 2.89 lbs. 1.61 lbs. 3.29 lbs. 2.01 lbs. 3.70 lbs. 2.82 lbs. 4.51 lbs.

OPTIONS

PACKAGING Bagged - Standard. Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20¢ from list price. FOR NO MOUNTING deduct 60¢ from the mounting clamp list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Listed for Water & Sewage

WE = Weighted Externally

Can be wired to work in either pump down (normally open) or pump up (normally closed) applications. NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

SPECIFICATIONS

CABLE: flexible 18 gauge, 3 conductor (UL) SJOW, water-resistant (CPE)

OTHER INFORMATION

NORMALLY OPEN (high level) OPERATION The control switch closes (turns on) when the float tips slightly above horizontal signaling a high level, and opens (turns off) when the float drops slightly below horizontal in potable water, water or sewage applications. NORMALLY CLOSED (low level) OPERATION The control switch closes (turns on) when the float tips slightly below horizontal signaling a low level, and opens (turns off) when the float tips slightly above horizontal in potable water, water or sewage applications.

CONTROL SWITCHES

(MECHANICAL)

FLOAT: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high impact, corrosion resistant polypropylene for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 5 amp, 125/250 VAC, 50/60 Hz This switch is not recommended for controlling: Q electric loads less than 100 milliamps, 12 VAC Q non-arcing electric loads

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

96

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011938G © SJE-Rhombus Printed in USA 11/07

SJE MILLIAMPMASTERTM Control Switch

Mechanically-activated control switch designed to activate low current control panels and alarms. This wide-angle or narrow-angle control switch offers reliable low current control for AC and DC applications in potable water, wastewater, and sewage. The internal switching mechanism has sealed gold cross-point contacts for reliable low current operation. Common applications include PLC (programmable logic controller) panels, IS panels with intrinsically safe barriers, low current solar applications, and other low current control panels and alarms applications. The wide-angle version activates/deactivates approximately 4" above and below horizontal with a 3.5" tether. The narrow angle version activates/deactivates at approximately 1.5" above and below horizontal with a 3.5" tether. Normally Open Model (high level) The control switch turns on (closes) when the float tips above horizontal signaling a high level, and turns off (opens) when the float drops below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the float drops below horizontal signaling a low level, and turns off (opens) when the float tips above horizontal.

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL,CSA) SJOW, water-resistant (CPE) jacket FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high-impact, corrosion resistant, polypropylene housing for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 125 VAC Maximum Electrical Load: 0.1 amps Minimum Electrical Load: 0.160 milliamps 30 VDC Maximum Electrical Load: 0.1 amps Minimum Electrical Load: 0.160 milliamps 5 VDC Minimum Electrical Load: 1 milliamps

FEATURES

Q Passed NSF Standard 61 protocol by an approved Water Quality Association laboratory. Q Low current, non-arching applications down to 0.160 mA at 125 VAC. Q Mechanically-activated, snap action contacts. Q High impact, corrosion resistant polypropylene float housing. Q Not sensitive to rotation. Q UL Listed for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

CONTROL SWITCHES

(MECHANICAL)

OPTIONS

This switch is available:

Q for normally open (high level) applications or normally closed (low level) applications. Q with narrow or wide-angle pumping ranges. Q in standard cable lengths of 10, 15, 20, or 30 feet. Q with two mounting options that allow for flexibility in installation:

Mounting Clamp: for applications where the switch can be attached to a discharge pipe or similar mounting device. Externally Weighted: for applications where the switch can be suspended from above. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

97

SJE MILLIAMPMASTERTM Control Switch

Mechanically-activated control switch designed to activate low current control panels and alarms.

PRICING/ORDERING INFORMATION Narrow-Angle Versions Normally Open Normally Closed

Part #

1018838 1018840 1018842 1018844 1018846 1018848 1018850 1018852

OPTIONS

Suggested List Price

$32.83 $38.96 $35.40 $41.52 $37.96 $44.08 $43.52 $49.64

Description

10MANPCNO 10MANWENO 15MANPCNO 15MANWENO 20MANPCNO 20MANWENO 30MANPCNO 30MANWENO

Part #

1018839 1018841 1018843 1018845 1018847 1018849 1018851 1018853

Description

10MANPCNC 10MANWENC 15MANPCNC 15MANWENC 20MANPCNC 20MANWENC 30MANPCNC 30MANWENC

Shipping Weight

1.04 lbs. 2.73 lbs. 1.37 lbs. 3.05 lbs. 1.69 lbs. 3.30 lbs. 2.34 lbs. 4.03 lbs.

PACKAGING Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20¢ from list price. No Mounting deduct 60¢ from mounting clamp list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Listed for Water & Sewage

Wide-Angle Versions Normally Open Normally Closed

Part #

1015725 1016181 1016184 1016186 1016211 1016213 1016215 1016217

Description

10MAPCNO 10MAWENO 15MAPCNO 15MAWENO 20MAPCNO 20MAWENO 30MAPCNO 30MAWENO

Part #

1016180 1016182 1016185 1016187 1016212 1016214 1016216 1016218

Description

10MAPCNC 10MAWENC 15MAPCNC 15MAWENC 20MAPCNC 20MAWENC 30MAPCNC 30MAWENC

Suggested List Price

$32.83 $38.96 $35.40 $41.52 $37.96 $44.08 $43.52 $49.64

Shipping Weight

1.04 lbs. 2.73 lbs. 1.37 lbs. 3.05 lbs. 1.69 lbs. 3.30 lbs. 2.34 lbs. 4.03 lbs.

Passed NSF standard 61 protocol by an approved Water Quality Association laboratory.

CONTROL SWITCHES

PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30)

(MECHANICAL)

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) jacket FLOAT: 2.74 inch diameter x 4.83 inch long (7.0 cm x 12.3 cm), high impact, corrosion resistant, polypropyline housing for use in sewage and water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi ELECTRICAL: 125 VAC Maximum Electrical Load: 0.1 amps Minimum Electrical Load: 0.160 milliamps 30 VDC Maximum Electrical Load: 0.1 amps Minimum Electrical Load: 0.160 milliamps 5 VDC Minimum Electrical Load: 1 milliamps

OTHER INFORMATION

NORMALLY OPEN (HIGH LEVEL) OPERATION The control switch closes (turns on) when the float tips above horizontal signaling a high level, and opens (turns off) when the float drops below normal. NORMALLY CLOSED (LOW LEVEL) OPERATION The control switch closes (turns on) when the float drops below horizontal signaling a low level, and opens (turns off) when the float tips above horizontal.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

98

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1016221G © SJE-Rhombus Printed in USA 11/07

SENSOR FLOAT® Control Switch

Mercury-activated, narrow-angle float switch designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in sewage and nonpotable water applications. The Sensor Float® control switch is not sensitive to rotation and is suitable for use with intrinsically safe circuits. Contact SJE-Rhombus regarding specific intrinsically safe applications. Normally Open Model (high level) The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level, and turns off (opens) when the float drops slightly below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the float drops slightly below horizontal signaling a low level, and turns off (opens) when the float tips slightly above horizontal.

FEATURES

Q Suitable for use with intrinsically safe circuits. Q Not sensitive to rotation. Q Control differential of .5 inches (1 cm) above or below horizontal. Q UL Listed for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL,CSA) SJOW, water-resistant (CPE) jacket FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high-impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi

OPTIONS

This switch is available:

Q for normally open (high level) applications or normally closed (low level) applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters. Q with three mounting options that allow for flexibility in installation:

Mounting Clamp: for applications where the switch can be attached to a discharge pipe or similar mounting device. Internally Weighted: for applications where the switch can be suspended from above. Externally Weighted: for applications where the switch can be suspended from above.

MERCURY TILT SWITCH: single pole, single throw, mercury-to-mercury contacts, hermetically sealed in a steel capsule and epoxy sealed in the float housing ELECTRICAL: 5 amp, 120/230 VAC, 50/60 Hz

CONTROL SWITCHES

(MERCURY)

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

99

SENSOR FLOAT® Control Switch

Mercury-activated, narrow-angle float switch designed to activate pump control panels and alarms.

PRICING/ORDERING INFORMATION Normally Open

Part #

1002108 1002072 1002143 1002117 1002080 1002152 1002125 1002089 1002161 1002134 1002098 1002170

Normally Closed

Part #

1002111 1002075 1002146 1002120 1002083 1002155 1002128 1002092 1002164 1002137 1002101 1002173

Description

10PCNO 10SWINO 10SWENO 15PCNO 15SWINO 15SWENO 20PCNO 20SWINO 20SWENO 30PCNO 30SWINO 30SWENO

Description

10PCNC 10SWINC 10SWENC 15PCNC 15SWINC 15SWENC 20PCNC 20SWINC 20SWENC 30PCNC 30SWINC 30SWENC

Suggested List Price

$33.12 $35.76 $39.72 $35.87 $38.52 $42.49 $38.64 $41.30 $45.26 $44.67 $47.31 $51.29

Shipping Weight

1.29 lbs. 1.85 lbs. 3.26 lbs. 1.64 lbs. 2.22 lbs. 3.50 lbs. 1.99 lbs. 2.59 lbs. 3.87 lbs. 2.13 lbs. 3.28 lbs. 4.48 lbs.

OPTIONS

PACKAGING Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20¢ from list price. No Mounting deduct 60¢ from mounting clamp list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Listed for Water & Sewage

PC = Pipe Clamp WI = Weighted Internally WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30).

SPECIFICATIONS

CONTROL SWITCHES

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) jacket FLOAT: 3.38 inch diameter x 4.55 inch long (8.58 cm x 11.56 cm), high impact, corrosion resistant, PVC housing for use in sewage and non-potable water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi MERCURY SWITCH: single pole, single throw, mercury-to-mercury contacts, hermetically sealed in a steel capsule and epoxy sealed in the float housing ELECTRICAL: 5 amp 120-/230 VAC, 50/60 Hz NOTE: Suitable for use with intrinsically safe circuits Contact SJE-Rhombus regarding specific intrinsically safe applications.

OTHER INFORMATION

NORMALLY OPEN (HIGH LEVEL) OPERATION The control switch closes (turns on) when the float tips slightly above horizontal signaling a high level, and opens (turns off) when the float drops slightly below normal. NORMALLY CLOSED (LOW LEVEL) OPERATION The control switch closes (turns on) when the float drops slightly below horizontal signaling a low level, and opens (turns off) when the float tips slightly above horizontal.

(MERCURY)

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

100

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011935G © SJE-Rhombus Printed in USA 11/07

SENSOR FLOAT® MINI Control Switch

Mercury activated, narrow-angle float switch designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in confined sewage and non-potable water applications. The Sensor Float® Mini control switch is not sensitive to rotation. Normally Open Model (high level) The control switch turns on (closes) when the float tips slightly above horizontal signaling a high level, and turns off (opens) when the float drops slightly below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the float drops slightly below horizontal signaling a low level, and turns off (opens) when the float tips slightly above horizontal. Contact SJE-Rhombus regarding intrinsically safe applications.

FEATURES

Q Designed for use in confined spaces. Q Not sensitive to rotation. Q Control differential of .5 inches (1 cm) above or below horizontal. Q UL Listed for use in non-potable water and sewage. Q CSA Certified. Q Three-year limited warranty.

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) jacket FLOAT: 2.81 inch diameter x 3.42 inch long (7.14 cm x 8.68 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC) MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi

OPTIONS

This switch is available:

Q for normally open (high level) applications or normally closed (low level) applications. Q in standard cable lengths of 10, 15, 20, or 30 feet and 3, 5, 6, or 10 meters (longer lengths available). Q with two mounting options that allow for flexibility in installation:

Mounting Clamp: for applications where the switch can be attached to a discharge pipe or similar mounting device. Externally Weighted: for applications where the switch can be suspended from above.

MERCURY TILT SWITCH: single pole, single throw, mercury-to-metal contacts, hermetically sealed in a steel capsule and epoxy sealed in the float housing ELECTRICAL: 5 amp, 120/230 VAC, 50/60 Hz This switch is not recommended for controlling:

(MERCURY)

CONTROL SWITCHES

Q electric loads less than 30 milliamps, 12 VAC Q non-arcing electric loads (intrinsically safe applications)

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

101

SENSOR FLOAT® Mini Control Switch

Mercury activated, narrow-angle float switch designed to activate pump control panels and alarms.

PRICING/ORDERING INFORMATION Normally Open

Part #

1002181 1002206

Normally Closed

Part #

1002184 1002209

Description

10MPCNO 10MWENO

Description

10MPCNC 10MWENC

Suggested List Price

$30.22 $37.08

Shipping Weight

1.20 lbs. 3.18 lbs.

OPTIONS

PACKAGING Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20¢ from list price. No Mounting - deduct 60¢ from mounting clamp list price. ADDITIONAL CABLE Additional cable length over 30 feet is available at 80¢ per foot (list price).

UL Listed for Water & Sewage

1002187 1002212

15MPCNO 15MWENO

1002190 1002215

15MPCNC 15MWENC

$33.12 $39.96

1.57 lbs. 3.41 lbs.

1002193 1002218

20MPCNO 20MWENO

1002196 1002221

20MPCNC 20MWENC

$35.99 $42.74

1.90 lbs. 3.74 lbs.

1002199 1002224

30MPCNO 30MWENO

1002202 1002227

30MPCNC 30MWENC

$42.13 $48.99

2.68 lbs. 4.56 lbs.

PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (10, 15, 20, 30)

SPECIFICATIONS

CABLE: flexible 18 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE) jacket

OTHER INFORMATION

NORMALLY OPEN (HIGH LEVEL) OPERATION The control switch closes (turns on) when the float tips slightly above horizontal signaling a high level, and opens (turns off) when the float drops slightly below horizontal. NORMALLY CLOSED (LOW LEVEL) OPERATION The control switch closes (turns on) when the float drops slightly below horizontal signaling a low level, and opens (turns off) when the float tips slightly above horizontal.

CONTROL SWITCHES

FLOAT: 2.81 inch diameter x 3.42 inch long (7.14 cm x 8.68 cm), high impact, corrosion resistant PVC housing for use in sewage and non-potable water up to 140oF (60oC)

(MERCURY)

MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi MERCURY TILT SWITCH: single pole, single throw, mercury-to-metal contacts, hermetically sealed in a steel capsule and epoxy sealed in the float housing ELECTRICAL: 5 amp 120/230 VAC, 50/60 Hz This switch in not recommended for controlling:

Q electric loads less than 30 milliamps, 12 VAC Q non-arcing electric loads

NOTE: Contact SJE-Rhombus regarding intrinsically safe applications.

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

102

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012516J © SJE-Rhombus Printed in USA 11/07

JUNCTION BOXES

Seals electrical connections from moisture and other elements. These junction boxes provide a convenient location to connect all wiring required for a typical pumping station, on-site system or other electrical installation.

FEATURES

NEMA 4X enclosure rated for outdoor use. External mounting feet included. Three-year limited warranty.

SPECIFICATIONS

LID AND BOX: UL Listed and CSA Certified made from high impact, corrosion resistant, weatherproof thermoplastic GASKET: flexible PVC or neoprene SCREWS: brass or stainless steel

OPTIONS

Junction Boxes are available with: 1/2", 3/4" or 1" UL Listed, CSA Certified round cable liquid-tight strain relief connectors (installed). 1/2" or 3/4" UL Listed, CSA Certified flat UF cable liquid-tight strain relief connectors (installed). 1", 1 1/2", or 2" terminal adapter hub (installed). Custom connector configurations available.

INTERNAL VOLUME: 4" x 4" x 4" is 50.65 cubic inches (830 cubic cm) 6" x 6" x 4" is 125 cubic inches (2048 cubic cm) 8" x 8" x 4" is 261.14 cubic inches (4280 cubic cm) EXTERNAL ENCLOSURE SIZE: 4 x 4 x 4 inches (10.16 x 10.16 x 11.43 cm) 6 x 6 x 4 inches (15.24 x 15.24 x 11.43 cm) 8 x 8 x 4 inches (20.32 x 20.32 x 11.43 cm)

ACCESSORIES

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

103

JUNCTION BOXES

Seals electrical connections from moisture and other elements.

Part #

1008546 1008872 1008547 1008548 1008549 1008550 1008551 1008552 1008553 JB444-1.5H-3R8 Simplex JB444-1.5H-4R8 Simplex

Description

JB444 (no connectors or hub installed)

List Price

$44.29 $71.98 $78.56 $52.24 $86.51 $95.36 $90.72 $103.80 $93.11

Ship Weight

2 lbs. 3 lbs. 3 lbs. 3 lbs. 4 lbs. 4 lbs. 4 lbs. 5 lbs. 5 lbs.

JB664 (no connectors or hub installed) JB664-1.5H-4R8 Simplex (small HP pump) JB664-2H-5R8 Duplex (small HP pump) JB664-1.5H-3R8-1R12 Simplex (large HP pump) JB664-2H-3R8-2R12 Duplex (large HP pump) JB884 (no connectors or hub installed)

NOTE: Descriptions grouped by enclosure size. All enclosure dimensions are in inches. Number before R8 or R12 equals the number of connectors of that size installed. 444 = 4 x 4 x 4, 664 = 6 x 6 x 4, 884 = 8 x 8 x 4. 1.5H = 1 1/2" HUB, 2H = 2" HUB. R8 = RCC8, R12 = RCC12. Small HP pump = Pump cable 18/2 to 14/3 gauge. Large HP pump = Pump cable 14/4 to 10/3 gauge.

SPECIFICATIONS

LID AND BOX: UL Listed and CSA Certified high impact, corrosion resistant, weatherproof thermoplastic GASKET: flexible PVC or neoprene SCREWS: brass or stainless steel VOLUME: 4" x 4" x 4" is 50.65 cubic inches (830 cubic cm), 6" x 6" x 4" is 125 cubic inches (2048 cubic cm), 8" x 8" x 4" is 261.14 cubic inches (4280 cubic cm) ENCLOSURE: 4" x 4" x 4" (10.16 x 10.16 x 11.43 cm), 6" x 6" x 4" (15.24 x 5.24 x 11.43 cm), 8" x 8" x 4" (20.32 x 20.32 x 11.43 cm)

FEATURES

External mounting feet included NEMA 4X, UL Listed, CSA Certified enclosure Flexible PVC or neoprene Gasket UL Listed and CSA Certified Hub for incoming power/control wires through conduit 1" hub available 1.5" standard with simplex version 2" standard with duplex version UL Listed, CSA Certified cable connectors provide strain relief and a liquid tight seal (RCC8, RCC12, RCC16, UFCC8, UFCC12)

SIDE VIEW

1 1/2"

4 X 4 X 4 SIMPLEX P/N 1008547 MODEL: JB444-1.5H-4R8

OTHER INFORMATION

CUSTOM CONNECTOR PLACEMENT Contact your customer service representative for custom connector placement and pricing.

ACCESSORIES

TOP VIEW

1 1/2"

6 X 6 X 4 SIMPLEX P/N 1008549 MODEL: JB664-1.5H-4R8

TOP VIEW

2"

6 X 6 X 4 DUPLEX P/N 1008550 MODEL: JB664-2H-5R8

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

104

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011969H © SJE-Rhombus Printed in USA 11/07

JUNCTION BOX PRICE WORKSHEET

COMPANY NAME: ______________ CONTACT: _________________________ PO #: ____________________ PHONE: ______________ FAX: _______________ EMAIL: _____________________ DATE: EXAMPLE: PRODUCT

Junction Box* Connectors Hub

______________

DESCRIPTION

JB664 RCC8 2"

LIST PRICE

$52.24 $6.58 $10.22

QUANTITY

1 6 1 SUBTOTAL X QUANTITY TOTAL DUE

TOTAL

$52.24 $39.48 10.22 $101.94 X2 $203.88

*Please choose only one junction box size.

YOUR WORKSHEET (LIMIT ONE CONFIGURATION PER WORKSHEET): PRODUCT

Junction Box* Junction Box* Junction Box* Connectors Connectors Connectors Connectors Connectors Hub Hub Hub

DESCRIPTION

JB444 JB664 JB884 RCC8 RCC12 RCC16 UFCC8 UFCC12 1" 1.5" 2"

LIST PRICE

$44.29 $52.24 $93.11 $6.58 $10.79 $13.63 $15.90 $18.17 $7.95 $7.95 $10.22

QUANTITY

TOTAL

*Please choose only one junction box size.

SUBTOTAL X QUANTITY TOTAL DUE XXXXXXXXX

ACCESSORIES

NOTE: If you need assistance in completing this worksheet, please call SJE-Rhombus Customer Service for assistance at 1-888-DIAL-SJE (1-888-342-5753).

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

www.sjerhombus.com

105

JUNCTION BOX CONNECTOR FORM

Please use this form when ordering junction boxes with special connector placements. This is a special order made specifically for SJE-Rhombus® customers. Special order products cannot be returned. COMPANY NAME: ______________ CONTACT: _________________________ PO #: ____________________ PHONE: ______________ FAX: _______________ EMAIL: _____________________ DATE: JUNCTION BOX INFORMATION - PLEASE CHECK BOX SIZE ______________

CONNECTORS AVAILABLE

4" X 4" X 4"

y RCC - 8 (1/2") y RCC - 12 (3/4") y RCC - 16 (1") authorized

placements only shown by C1

y UFCC - 8 (1/2") y UFCC - 12 (3/4") y 1" HUB y 1.5" HUB y 2" HUB

NOTE: Available with a 1" or 1.5" hub. Hub is always placed in the center of selected side. No other connectors can be installed on the same side as the hub.

NOTE: For 6" x 6" x 4" junction box, connectors at locations C4, C5, A4 and A5 may make mounting feet difficult to access.

6" X 6" X 4" 8" X 8" X 4"

LOCATION CONNECTOR 1 2 3 4 5 6 7 8

HUB

ACCESSORIES

NOTE: Available with a 1", 1.5", or 2" hub. Hub is always placed in the center of selected side. No other connectors can be installed on the same side as the hub. 2" hub can't be mounted on the D side (hinge side) of the 8" x 8" x 4" junction box. FOR SJE-RHOMBUS INTERNAL USE ONLY ORDER# ________________ CONFIGURATION#: __________________

NOTE: If you need assistance in completing this form, please call SJE-Rhombus Customer Service.

9 10

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

106

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1021765B © SJE-Rhombus Printed in USA 11/07

ACCESSORIES

Cable Weight, Hub Assembly, Float Bracket, Cable Connectors, Cord Seal, Cable Clamp Assembly, Pressure Transducers, Anchor, Chain, and Vertical Reed Switch.

CABLE WEIGHT

Provides an accurate pivot point for suspended float switches. Q Gripper teeth on clip and weight channel securely

Q

lock float cable into place Cable Weight can be adjusted without the use of tools

CABLE CONNECTORS

Provides strain relief and a liquid-tight seal. Q UL Listed and CSA Certified

VDE Approved

U.S. Patent 5,306,885

ROUND CABLE SPECIFICATIONS

MATERIAL: polymid flame-resisting, self-extinguishing plastic O RING: neoprene plastic HOLE REQUIREMENT: NPT threaded OR clearance holes (jam nutincluded)

HOUSING: 1 pound, 12 ounce (0.8 kgs.), 2.8 inch diameter x 3.3 inch long (7.1 cm diameter x 8.4 cm), impact resistant, non-corrosive, PVC housing for use in liquids up to 140oF (60oC) CLIP: injection molded acetal plastic WIRE/CABLE ACCOMMODATED: SJOW, SJTW, 18/2, 18/3, 16/2, 16/3, 14/2 and 14/3

Part Number Description

1002230 Cable Weight

List Price

$8.86

HUB ASSEMBLY

Provides liquid-tight conduit attachment location.

Q Q

Available in 1, 1.5 and 2 inch sizes. UL Listed and CSA Certified terminal adapter

TERMINAL ADAPTER (HUB): PVC GASKET: neoprene LOCK NUT: metal

RCC-8 nut NPT Hub: .5 inch (1.27cm) O ring Maximum Diameter: .480 inch (1.22 cm) jam nut Minimum Diameter: .270 inch (.68 cm) Wire/Cable (AWG) Accommodated: 18/2, 18/3, 18/4, 16/2, 16/3, 16/4, 14/2, and 14/3 RCC-12 NPT Hub: .75 inch (1.90 cm) Maximum Diameter: .709 inch (1.80 cm) Minimum Diameter: .545 inch (1.38 cm) Wire/Cable (AWG) Accommodated: 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, and 10/3 RCC-16 NPT Hub: 1.0 inch (2.54 cm) Maximum Diameter: .98 inch (2.49 cm) Minimum Diameter: .71 inch (1.80 cm) Wire/Cable (AWG) Accommodated: Round cable with outside diameter within range indentified above.

sealing

Part Number Description

1009305 1 inch Hub Assembly 1008848 1.5 inch Hub Assembly 1008849 2 inch Hub Assembly

List Price

$7.95 $7.95 $10.22

Part Number Description

1002574 1/2 inch Round Cable Connector (RCC-8) 1002575 3/4 inch Round Cable Connector (RCC-12) 1009868 1 inch Round Cable Connector (RCC-16)

List Price

$6.58 $10.79 $13.63

FLOAT BRACKET

Provides convenient installation of float switches.

FLAT UF CABLE SPECIFICATIONS

MATERIAL: weather-stabilized thermo plastic O RING: neoprene plastic HOLE REQUIREMENT: NPT threaded OR clearance holes (jam nut included)

Q Q Q Q Q

Six Float Bracket supports 1-6 floats Four Float Bracket supports 1-4 floats Can be directly mounted to wall or used with wall mounting device Provides convenient location to stow excess float cord Supplied with UL Recognized cord strain relief connectors

sealing nut

METAL COMPONENTS: all metal components are made of 300 series stainless steel STRAIN RELIEF CONNECTORS: which accommodate 18/2, 18/3, 16/ 2, 16/3 SJOW and SJTW cords

UFCC-8 O ring NPT Hub: .50 inch (1.27 cm) jam nut Maximum: .26 x .56 inch slot Wire/Cable (AWG) Accommodated: 14/2, 12/2, 10/2 UFCC-12 NPT Hub: .75 inch (1.90 cm) Maximum: .26 x .60 inch slot Wire/Cable (AWG) Accommodated: 14/3, 12/3

ACCESSORIES

Part Number Description

1009432 1009433 1009434 1009435 1009436 4 Float Bracket With Mounting Device 4 Float Bracket Without Mounting Device 6 Float Bracket With Mounting Device 6 Float Bracket Without Mounting Device Float Bracket Mounting Device

List Price

$54.51 $47.69 $61.32 $54.51 $13.63

Part Number Description

1002576 1/2 inch Flat UF Cable Connector (UFCC-8) 1002577 3/4 inch Flat UF Cable Connector (UFCC-12)

List Price

$15.90 $18.17

PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]

PRODUCTS CONTINUED ON NEXT PAGE.

www.sjerhombus.com 107

ACCESSORIES

Cable Weight, Hub Assembly, Float Bracket, Cable Connectors, Cord Seal, Cable Clamp Assembly, Pressure Transducers, Anchor, Chain, and Vertical Reed Switch.

CORD SEAL

Provides strain relief and a liquid-tight seal.

MODEL 700 TRANSDUCER

Provides reliable liquid level measurement and control for well monitoring, pump control, lift stations, level control, ground water/surface water monitoring applications.

Q Q Q

Seals 1-3 cables in 2" terminal adapters 2 PVC plugs included (for unused cable positions) Ground wire

SEAL: neoprene WASHERS: stainless steel NUT AND BOLT: stainless steel WIRE/CABLE ACCOMMODATED: SJOW, SJTW, 18/2, 18/3, 16/2, 16/3,14/2 and 14/3

Q Q Q Q Q Q Q Q

Part Number Description

1008517 Cord Seal

List Price

$29.53

Construction: welded 316 stainless steel Open faced nose cap Excitation voltage: 9-30 VDC Analog output: 4-20mA 0-10 PSI 40' molded polyurethane 4 conductor vented cable with vent filter to prevent moisture in cable tube Static accuracy: +/- .01 Zero offset: +/- 0.20mA

CABLE CLAMP ASSEMBLY

Provides cable anchor point and strain relief. Secures cable in vertical direction.

**Call Factory for quote.

MODEL 710 TRANSDUCER

Provides reliable liquid level measurement and control for well monitoring, pump control, lift stations, level control, ground water/surface water monitoring applications.

Q Q Q

For use with 18/16 gauge, 14 gauge, & 12 gauge cable Mounting clamp: ABS Nylon blend Hose clamp: highly corrosion resistant stainless steel

Part Number Description

1008569 18 & 16 Gauge Cable Clamp Assembly 1008574 14 Gauge Cable Clamp Assembly 1008575 12 Gauge Cable Clamp Assembly

List Price

$3.26 $3.26 $3.26

Q Q Q Q Q Q Q Q

ANCHOR

Q Q

10 lb. weight Yellow, vinyl coated, mushroom style

Construction: welded 316 stainless steel Open faced nose cap Excitation voltage: 9-30 VDC Analog output: 4-20mA 0-10 PSI 40' molded polyurethane 4 conductor vented cable with vent filter to prevent moisture in cable tube Static accuracy: +/- .05 Zero offset: +/- 0.20mA

**Call Factory for quote.

VERTICAL REED SWITCH

Part Number Description

1018687 10 lb. Mushroom Anchor

List Price

$42.00

Q Q Q Q

ACCESSORIES

CHAIN

Q Q Q

1/8" thickness 316 grade stainless steel Available in one foot increments

Control differential: .375 inch (1 cm) Maximum angle from vertical: 5° Electrical: 250 mAmps, 12-25 VAC, 50/60 Hz 500 mAmps, 6-12 VDC, 50/60 Hz Housing and Float: 1.60 inch diameter x 6.7 inch long (4.06 cm X 17.01 cm), high impact, corrosion resistant PVC for use in sewage and non-potable water up to 120°F (50°C)

Part Number Description

1011027 10ft VRS 120V Bulk 1016561 15ft VRS 120V Bulk

List Price

$58.75 $62.42

Part Number Description

1018823 1/8 inch Chain

List Price

$8.61 per foot

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

108

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1011968K © SJE-Rhombus Printed in USA 11/07

HOME PROTECTION PRODUCTS

Easy-to-install home monitoring products that provide notification of conditions such as threatening liquid level and low temperature. The Auto Dialer is a single channel voice dialer that can be used with any device that can provide a normally open or normally closed contact. The Auto Dialer can be programmed to store up to four numbers to dial, including standard (voice) telephones, most cellular telephones, and pagers. The Auto Dialer will deliver a recorded message for up to 16 seconds. Note: The Auto Dialer AVD-45b will attempt to deliver the outgoing message twice with a maximum of 10 attempts for each telephone number. The Home Temperature Monitor switch provides a means to monitor environmental temperature. When used with the Auto Dialer, the system will notify of potentially threatening freezing conditions. This can be used to help eliminate costly damage of freezing water pipes. Home Temperature Monitor

Auto Dialer

AUTO DIALER FEATURES

Non volatile (EEPROM) memory for voice message and telephone numbers. Calls up to four telephone numbers, any combination of telephone or pagers. Sends up to 16 second voice message to telephones or numeric code to pagers. Record your own message in any language. Easily change message and telephone numbers without a programmer. Voice chip technology (no tape required). Ability to program up to 10 (2-second) pauses and pound (#) for pager dialing. Dials each outgoing telephone number a maximum of 10 times. 2x16 character LCD window. Internal playback speaker for voice message. Programmable Exit and Entry delay. Internal 9V battery backup. Works with PBX or regular telephone system. Tone or Pulse dialing (not intended for digital telephone lines). NC, NO, momentary, continuous or voltage activation. Internal protection against transient overload conditions. Three-year limited warranty.

AUTO DIALER SPECIFICATIONS

ENCLOSURE: 6.0 x 4.0 x 1.5 inch, indoor VOLTAGE: 9-18 VDC (12 VDC plug in power supply included) BATTERY BACKUP POWER: 9 VDC ACTIVATION: NO or NC, momentary or continuous dry contact activation Voltage activation: 0 to +V (NC operation) or +V to 0 (NO operation) Note: +V limited from 5-28 VDC PHONE NUMBERS STORED: Up to 4 MAXIMUM DIGITS/PHONE NUMBER: 28 (including pauses) PROGRAMMABLE PAUSES: 10 max.

HOME TEMPERATURE MONITOR SPECIFICATIONS

ENCLOSURE: 2.25 x 2.5 x 1.0 inch, indoor VOLTAGE: Contacts: 24 VDC, 120 mA maximum Switch opens at 40°F ± 5°F Switch closes at 55°F ± 5°F

ACCESSORIES

OPTIONS

Auto Dialer is available with: Home Temperature Monitor switch.

HOME TEMPERATURE MONITOR FEATURES

Provides an enclosed preset thermal switch and screw terminals for easy connection. The switch is normally closed when the temperature is above 40°F. When the temperature drops below 40°F the switch opens. The switch remains open until the temperature rises above 55°F at which point the switch closes again. One-year limited warranty. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE · 1-218-847-1317 1-218-847-4617 Fax email: [email protected]us.com

SEE BACKSIDE FOR PRICING/ORDERING INFORMATION.

www.sjerhombus.com

109

HOME PROTECTION PRODUCTS

Easy-to-install home monitoring products that provide notification of conditions such as threatening liquid level and low temperature.

PRICING/ORDERING INFORMATION

Part #

1012019 1012052 1012103 Auto Dialer Home Temperature Monitor

Description

List Price

$435.00 $43.00 $477.00

Ship Weight

1.25 lbs. .01 lbs. 1.26 lbs.

Auto Dialer w/Home Temperature Monitor

AUTO DIALER SPECIFICATIONS

ENCLOSURE: 6.0 x 4.0 x 1.5 inch, indoor VOLTAGE: 9-18 VDC (12 VDC plug in power supply included) BATTERY BACKUP POWER: 9 VDC ACTIVATION: NO or NC, momentary or continuous dry contact activation Voltage activation: 0 to +V (NC operation) or +V to 0 (NO operation) Note: +V limited from 5-28 VDC PHONE NUMBERS STORED: Up to 4 MAXIMUM DIGITS/PHONE NUMBER: 28 (including pauses) PROGRAMMABLE PAUSES: 10 max.

HOME TEMPERATURE MONITOR SPECIFICATIONS

ENCLOSURE: 2.25 x 2.5 x 1.0 inch, indoor VOLTAGE: Contacts: 24 VDC, 120 mA maximum Switch opens at 40°F ± 5°F Switch closes at 55°F ± 5°F

ACCESSORIES

Call or fax your order!

1-888-DIAL-SJE (1-888-342-5753)

110

Fax 218-847-4617

www.sjerhombus.com [email protected]

Cat Page PN 1012180G © SJE-Rhombus Printed in USA 11/07

JB Plugger Junction Box Installation Instructions

This junction box provides a convenient location to connect all wiring required for a typical pumping station installation. The junction box employs a receptacle to accept a 120 VAC or 230 VAC piggy-back plug and a pump plug. The JB Plugger also features an easy-to-use terminal strip which can be used for connecting an alarm system in the junction box. The JB Plugger package ensures a liquid-tight seal and strain relief for the cable entering the junction box from the pumping station.

JB PLUGGER JUNCTION BOX

Q NEMA 4X enclosure rated for outdoor use. Q Hinged cover for convenience. Q Receptacle for pump & pump switch (120V or 230V). Q Custom engineered liquid-tight cord seal. Q Strain relief for pump and float cords provided by cord seal. Q Terminal strip for use with alarm system. Q Separate alarm and pump control circuitry provided by terminal strip. Q Dual safety certification for the United States and Canada. Q Three-year limited warranty.

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the floats are free to move and operate the pump and alarm. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

111

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

INSTALLING THE JB PLUGGER JUNCTION BOX

1. Determine where the junction box will be mounted on the riser. Mount the junction box so the base of the enclosure will be at grade once backfilled as shown in Figure A. NOTE: Bottom mounting to the 3/4" terminal adapter may be preferred in some instances as shown in Figure B. 2. Access the riser by providing a 2 3/8" access hole through the riser. 3. Place the 6" threaded conduit into the terminal adapter that is already installed in the junction box. Slip one PVC washer over the conduit and slide the conduit through the riser wall as shown in Figure C. 4. After installation through the riser, slip the 1/2" gasket and the second PVC washer over the conduit. Determine if the threads provided will be adequate to tighten the assembly to the riser. If threading is not adequate, remove the assembly and shorten the conduit until threading is adequate as shown in Figure C. NOTE: The 1/2" gasket should compress approximately 1/4" when lock nut is tightened. 5. Repeat steps 3 and 4 until desired length is achieved. With PVC solvent, weld the conduit into the terminal adapter. 6. Mount the 3/4" terminal adapter to the bottom of the junction box with the Oring and lock nut provided. A 1 1/16" hole should be provided for the adapter. 7. Mount the assembly through the riser as described in steps 3 and 4. Using the 2" lock nut, compress the gasket and riser to secure the junction box. 8. Remove the backplate assembly from the enclosure. Bring the wiring for the pump power and alarm junction through the 3/4" terminal adapter. Connect the conductors for the pump to the terminal block; connect N (neutral) to position 1, and L1 (line) to position 2. Connect L2 to position 1 for 230 VAC installations. NOTE: Overload protection, branch circuit protection and main disconnect provided by others. Connect the conductors for the alarm circuit to positions 3 and 4 as shown in Figures C and D. Place the backplate assembly back into the enclosure. NOTE: If an alarm system is not used, plug the third open position in the cord seal with the PVC plug provided. 9. Pass the piggy-back plug, pump plug and alarm float cables through the 2" conduit. 10. With the three position cord seal, route the three cables through the seal, leaving approximately 8" of cable to work with. Insert the cord seal into the panel terminal adapter and tighten the hex nut until adequate strain relief is achieved. 11. Gather all ground wires, including grounding conductor on the cord seal, and washer. Route and secure to ground terminal as shown in Figures C and D. 12. Connect the conductors from the alarm float switch to positions 3 and 4. Coil remaining cable into the junction box as shown in Figures C and D. 13. Seal the 3/4" terminal adapter with a conduit sealing compound. 14. Plug the piggy-back plug and pump plug into the receptacle as shown in Figure D. 15. Secure the junction box cover using the two preinstalled screws. 16. Turn on power. 17. Check the installation by manually tipping the floats on the pump and then the alarm float. 18. Test the unit periodically to insure proper operation.

Figure C

torque to 45 in-lbs ground pump power pump float switch receptacle 12 3 4 N L1 torque to 7 in-lbs to alarm panel alarm float

cord seal

terminal adapter riser wall

PVC washer

gasket PVC washer

lock nut

Figure D

pump plug

Figure A

riser PVC washer gasket PVC washer pump & switch cables JB Plugger

Figure B

JB Plugger

3" 2 1/16"

cable coiling detail to alarm panel alarm float switch

riser

grade level

3/4" adapter location grade level conduit for electrical (not included) LB conduit box (not included) spacer for lip on riser lid (not included)

lock nut

terminal adapter

3/4" terminal adapter conduit for electrical (not included)

pump & switch cables

piggyback plug

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

112

Instl. Instr. PN 1011983G ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® AB Alarm Installation Instructions

This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert® AB indoor alarm system can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the alarm light remains on until the condition is remedied. Once the condition is cleared the alarm will automatically reset. A green "Power On" light indicates 120 VAC primary power to the alarm. Low battery chirp feature indicates when battery should be replaced.

TANK ALERT® AB ALARM

Q 120 VAC Model Voltage - (circuits not supervised) Primary: 120 VAC, 60 Hz, 2.4 watts maximum (alarm condition) Operating Voltage: 9 VDC Double insulation Q NEMA 1 enclosure rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch. Q 6 foot (1.8 meter) power cord. Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q Can be used with any UL Listed switching mechanism rated to include 1 amp, 9 VDC load. Q Maximum line impedance for initiating device: 5 ohms. Q If primary power fails, the alarm system continues to work due to battery backup feature. Battery Backup Power - (circuit not supervised) 9 VDC Q Complete package includes standard SJE SignalMaster® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Low battery chirp. Q External terminal block for easy float switch installation. Q Three-year limited warranty.

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q splice kit.

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. 113

INSTALL INSTRUCTIONS

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web site at www.sjerhombus.com.

INSTALLING THE ALARM & FLOAT SWITCH

1. Determine indoor mounting location for alarm. 2. Insert screw (supplied) at desired wall location. Note: Screw is to be located over wall stud or used with a wall anchor sized for a #8 x 1.25" self tapping screw. 3. Hang alarm using keyhole on back of enclosure. Install second screw in mounting flange located on bottom of alarm. 4. Make sure power to alarm is disconnected. 5. Place the float switch cord into the clamp as shown in Figure A. 6. Locate the clamp at the desired activation level and secure the clamp to the discharge pipe as shown in Figure A. Note: Do not install cord under hose clamp. 7. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements. 8. Bring cable leads back to alarm and wire according to Figure B. Note: When used with a pump application, connect alarm to a circuit separate from the pump circuit. This allows the alarm to operate if the pump circuit fails. 9. Open battery door and install 9 VDC alkaline battery (not included). Battery must be installed for backup alarm to function. Note: The green power on light does not come on when unit is on battery power. 10. Plug the alarm in to apply primary power. Verify that the green "power on" light illuminates. 11. Check installation by manually tipping the float. The horn will sound and the "alarm" light should come on. 12. Press "silence" button to silence the horn. The horn will silence while the red "alarm" light stays on. 13. Tip float back down and press "test" button. The "alarm" light and horn will activate. 14. Test unit once a week. Replace battery every 12 months and after each alarm condition to ensure proper operation. If battery is low, low battery chirp feature will cause the horn to chirp approximately once per minute. Replace battery when this happens. 15. Using the provided cable clasp, secure cord to outlet as shown in Figure C. Use existing receptacle faceplate screw and supplied washer. 16. Test unit once per week to insure proper operation.

Figure A

3.5 inch (9 cm) tether length

Figure B

Figure C

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

114

Instl. Instr. PN 1012188F ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® ABP alarm panel Installation Instructions

The Tank Alert® ABP indoor alarm panel provides a reliable means of controlling a 120 VAC single phase pump in water and wastewater installations. Two switches, one for the pump and one for the high water alarm, are spliced together for easy installation. The Tank Alert® ABP alarm panel horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the alarm light remains on until the condition is remedied. Once the condition is cleared the alarm panel will automatically reset. A green "Power On/Pump Run" light indicates 120 VAC primary power to the alarm, and also flashes to indicate the pump run status. Low battery chirp feature indicates when battery should be replaced.

TANK ALERT® ABP ALARM PANEL

Q 120 VAC Model Voltage - (circuits not supervised) Primary: 120 VAC, 60 Hz, 2.4 watts maximum Operating Voltage: 9 VDC Q NEMA 1 enclosure rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on/pump run" light, alarm "test" switch, and horn "silence" switch. Q 6 foot (1.8 meter) power cord Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q Manual pump run operation. Q If primary power fails, the alarm panel continues to work due to battery backup feature. Battery Backup Power - (circuit not supervised) 9 VDC Q Complete package includes two factory-spliced SJE MilliAmpMasterTM control switches with 10 feet (3.05 meters) of cable and mounting clamp. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Receptacle on bottom to plug in pump power cord. Q Low battery chirp. Q External terminal block for easy float switch installation. Q Three-year limited warranty.

Patent Pending

· · · · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the floats are free to move and operate the switches. Use only SJE-Rhombus® replacement parts. For indoor use only. Pump must have integral thermal overload protection.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

115

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web site at www.sjerhombus.com.

INSTALLING THE ALARM PANEL & FLOAT SWITCHES

1. Determine indoor mounting location for alarm panel. 2. Insert screw (supplied) at desired wall location. Note: Screw is to be located over wall stud or used with a wall anchor sized for a #8 x 1.25" self tapping screw. 3. Hang alarm panel using keyhole on back of enclosure. Install second screw in mounting flange located on bottom of alarm panel. 4. Make sure power to alarm panel is disconnected. 5. Use only with factory-spliced float switches provided. Place the float switch cords into the clamps as shown in Figure A. 6. Locate the floats at the desired activation level and secure the clamps to the discharge pipe as shown in Figure A. Note: Do not install cord under hose clamp. 7. Tighten the hose clamps using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cables are not allowed to touch the excess hose clamp band during operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus ® supplier for replacements. 8. Along with pump power cord, bring cable leads back to alarm panel and wire according to Figure B. 9. Inspect installation and cords before continuing. 10. Open battery door and install 9 VDC alkaline battery (not included). Battery must be installed for backup alarm to function. Note: The green power on light does not come on when unit is on battery power. 11. Plug the alarm panel in to apply primary power. Verify that the green "power on" light illuminates. Note: Must use GFI protected receptacle. 12. Check installation by manually tipping the floats. The horn will sound and the "alarm" light should come on. The pump will energize and the "pump run" light will blink when the pump float is tipped. 13. Press "silence" button to silence the horn. The horn will silence while the red "alarm" light stays on. 14. Tip floats back down and press "test" button. The "alarm" light and horn will activate. Press the "test" and "silence" buttons together. The pump will energize and the "pump run" light will blink. 15. Test unit once a week. Replace battery every 12 months and after each alarm condition to ensure proper operation. If battery is low, low battery chirp feature will cause the horn to chirp approximately once every four minutes. Replace battery when this happens. 16. Using the provided cable clasp, secure cord to outlet as shown in Figure C. Use existing receptacle faceplate screw and supplied washer. 17. For pump power cable strain relief, use the supplied tie strap to bundle float, pump power, and alarm panel power cables 6 inches below alarm panel.

Figure A

tether length

tether length

(inches)

3.5 min. 8

6 11

9 15

12 21

15 28

18 31

22 36

pumping range

(inches)

Figure B

Figure C

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

116

Instl. Instr. PN 1017097E ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® ABW (Wireless) Alarm Installation Instructions

The Tank Alert® ABW alarm system features a battery operated wireless transmitter that is placed in a tank (up to 150 feet away from the indoor alarm). When the high water alarm float switch activates, the transmitter sends a signal and sounds the indoor alarm warning of a potentially threatening liquid level condition. The horn can be silenced, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. The Tank Alert® ABW alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, effluent filters, and other water applications.

TANK ALERT® ABW ALARM FEATURES

Q 120 VAC Voltage - Primary: 120 VAC, 60 Hz, 2.4 watts maximum (alarm condition); Operating Voltage: 9 VDC. Q NEMA 1 enclosure rated for indoor use. Q Automatic alarm reset. Q Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch. Q 6 foot (1.8 meter) power cord. Q Alarm horn sounds at 87 decibels at 10 feet (3 meters). Q If primary power fails, the alarm system continues to work due to battery backup feature. Battery Backup Power: 9 VDC (Battery not included.) Q Package includes standard internally weighted Sensor Float® control switch with 10 feet (3.04 meters) of cable with transmitter. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Low battery chirp. Q Loss of signal alarm. After 3 hours and 15 minutes without a signal, an alarm sounds and the red light blinks.

Shown with optional mounting bracket.

Q External terminal block for an optional local alarm float. Q Q

TANK ALERT® ABW TRANSMITTER FEATURES

Q Wireless transmitter with up to 150 foot range Q Long life 3.6V lithium battery (recommended replacement 2 years)

Meets all FCC requirements Transmitter transmits once per hour or when the float position is changed

OPTIONS

Q Mounting bracket

Alternate float switch models:

Q Q

UL Listed component model available SJE MilliAmpMasterTM control switch (N.C.)

Q Sensor Float® control switch (N.C.) Q SJE MilliAmpMasterTM control switch (N.O.)

· · · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the preformance of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Replace batteries as specified in instructions. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

INSTALL INSTRUCTIONS

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. 117

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web site at www.sjerhombus.com.

INSTALLATION REQUIREMENTS

1. Please note the following requirements when determining a location for installation: Q Do not mount the transmitter more than 2" below ground. The further below ground the unit is installed, the shorter the range becomes. Q Do not use a metal riser cover. It will severely limit the range of the unit. Q Note what is between the receiver and transmitter. An RV, pole shed, or any large metal object may cause transmission problems. Individual vehicles such as cars and SUV's will not be a concern. Q The transmitter and receiver operate on a line-ofsight basis; where the signal goes straight to the receiver. Steep inclines may cause there to be no clear line of site between the receiver and the transmitter. (See Figure G on back page.) Q Metal buildings and buildings with aluminum siding may cause the unit to have a shorter range. In some cases, it may be better to mount the receiver unit on a wall perpendicular to the transmitter. Q AC power tools used continuously in excess of 3 hours may cause loss of transmission alarm. 1.

INSTALLING THE RECEIVER (ALARM)

Determine the location of the receiver (alarm) unit. Please note the following requirements when determining a location for mounting the receiver: Q Do not install receiver (alarm) in a basement. Q Do not install receiver (alarm) near a computer or radio. These items may limit receiver's ability to pick up a signal. Q Mount receiver (alarm) as close to transmitter (float) as possible. (Do not exceed 150 feet.) Q Mount receiver and plug it into a 120 VAC wall outlet. Insert screw (supplied) at desired wall location. Note: Screw is to be located over wall stud or used with a wall anchor sized for a #8 x 1.25" self tapping screw. Hang alarm using keyhole on back of enclosure. Install second screw in mounting flange located on bottom of alarm. Make sure power to alarm is disconnected. Bring optional alarm float cable leads back to receiver unit and wire according to Figure A. Note: When used with a pump application, install optional 9 VDC battery This allows the receiver to operate if the pump circuit fails. To install backup alarm battery (optional), open battery door and install 9 VDC alkaline battery (not included). Do not use heavy duty/non-alkaline batteries. Battery must be installed for backup alarm to function. Note: The green power on light does not illuminate when unit is on battery power. Plug the alarm in to apply primary power. Verify the green "power on" light illuminates. Install 3.6 VDC lithium battery in transmitter. The negative terminal on the battery connects to the spring side of the battery holder. Check operation by manually tipping float up. After a 10 second delay, the horn will sound and the "alarm" light will come on. Press "silence" button to silence the horn. The horn will silence while the red "alarm" light stays on. Tip float back down. After a 10 second delay the alarm light will turn off. Press "test" button. The "alarm" light and horn will activate. Reset the alarm by removing all 120V and 9 VDC power. Remove the 3.6 VDC battery from transmitter. Reapply power to the receiver unit. Do not insert transmitter battery at this time. Replace 9 VDC battery every 12 months and after each alarm condition to ensure proper operation. If battery is low, the low battery chirp feature will cause the horn to chirp approximately once per minute. Replace battery if this occurs. Note: Non-alkaline batteries may cause a low battery chirp even when they are new. Using the provided cable clasp, secure cord to outlet as shown in Figure B. Use existing receptacle faceplate screw and supplied washer. Test unit once per week to insure proper operation.

2.

3.

4. 5.

6.

Figure A

7. 8.

9.

10. 11.

Figure B

12.

12.

INSTALL INSTRUCTIONS

13.

14.

118

INSTALLING THE TRANSMITTER (FLOAT)

NOTE: DO NOT CUT FLOAT CABLE. 1. To monitor high level conditions determine the correct activation level for the float. 2. Suspend switch at desired activation level as shown in Figures C & D. Note: Switch remains partially submerged during "on" tipping action. 3. Coil any excess cord. Secure extra cord with zip ties provided. 4. When using optional mounting bracket, line up the arrows on top of transmitter with those on mounting bracket and receiver. If mounting bracket is not used, arrow alignment is not needed. This bracket can be used when mounting the transmitter in a standard riser as shown in Figure E. If the unit is being mounted in a 4 or 6 inch PVC pipe, drill a 1 3/ 8 inch hole in the top of the PVC cap and mount transmitter through the cap as shown in Figure F. 5. Place battery in correct polarity and replace battery holder back inside unit. Negative terminal on battery connects to spring side of battery holder. 6. Apply thread compound that is suitable for PVC to threads of holder. Do not use teflon tape. 7. Replace grey cap. Wait at least three minutes. Once battery is installed, the transmitter will wait three minutes to transmit a signal. During the 3 minute wait, drop the float into place and replace all tank covers. 8. After three minutes have elapsed, press and hold "test" and "silence" buttons on receiver. A flashing green light signifies a good installation. A flashing red light signifies either the unit did not receive any signal or the signal was not strong enough for reliable operation. Move receiver to a different location. Note: A change in location as minor as moving it up vertical one foot could allow it to operate reliably. 9. Replace battery every 2 years.

Figure C - Internally weighted float

7 inches (18 cm) approximate activation level

Figure D - Tethered float

3.5 inch tether length

approximate activation level of 4 inches above or below horizontal

Figure E - Standard Riser Installation

ALARM LIGHT KEY

Solid Red: Remote Alarm Remote (wireless) alarm has been triggered. Check location of transmitter unit to determine if an alarm condition is occurring. Fast Blink Red: Local Alarm Local alarm (float connected to terminal block) has been triggered. Check chamber in which local alarm float is used. Slow Blink Red: No Signal The receiver is not communicating with the transmitter. Check transmitter battery voltage (3.6V) and/or the area between transmitter and receiver for obstructions such as large vehicles or RV. Slow-Fast Blink Red: Multiple Alarms Several alarms are triggered. 1. Check local alarm float (if used). 2. Check level in the tank with a remote alarm. 3. Check transmitter battery. Solid Green: Primary Power 120 VAC power present. Green Light Off: Unit is no longer operating off of 120 VAC power and is operating off of 9 VDC battery backup (if battery is installed). Horn Chirp: Low battery or non-alkaline battery was used. Replace 9 VDC backup battery with a new alkaline battery.

Figure F - PVC Pipe Installation

INSTALL INSTRUCTIONS

119

FCC INFORMATION

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Q Reorient or relocate receiving antenna. Q Increase separation between equipment and receiver. Q Connect equipment into an outlet on a circuit different from that to which the receiver is connected. Q Consult dealer or an experienced radio/TV technician for help.

This equipment has been certified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user's authority to operate this equipment.

FCC ID #: SCP TAABW01 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

Q This device may not cause harmful interference. Q This device must accept any interference received, including interference that may cause undesired operation.

Figure G - Line-Of-Sight Illustration

acceptable lines of sight

acceptable line of sight

unacceptable line of sight

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

120

Instl. Instr. PN 1016028E ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® I Alarm Installation Instructions

This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® I indoor alarm system can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be turned off, but the warning light remains on until the condition is remedied. A green "power on" light indicates power to the alarm panel.

TANK ALERT® I ALARM

Q 120 VAC Model Voltage - (circuits not supervised) Primary: 120 VAC, 50/60 Hz, 5 watts maximum (alarm condition) Secondary: 12 VAC 230 VAC Model Voltage - (circuits not supervised) Primary: 230 VAC, 50/60 Hz, 5 watts maximum (alarm condition) Secondary: 12 VAC Q NEMA 1 enclosure rated for indoor use. Q Red warning light, green "power on" light, alarm test switch, and horn silence switch. Q Alarm horn sounds at 86 decibels at 10 feet (3 meters). Q 6 foot (1.8 meter) power cord. Q Can be used with any switching mechanism rated to include 1 amp, 12 VAC load. Q Maximum line impedance for initiating device: 5 ohms. Q Alarm system (when installed on separate circuit) operates even if the pump circuit fails. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Q Three-year limited warranty.

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q 120 VAC primary voltage or 230 VAC primary voltage. Q splice kit.

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

INSTALL INSTRUCTIONS

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. 121

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

INSTALLING THE ALARM & FLOAT SWITCH

1. Determine indoor mounting location for alarm panel. 2. Insert screw (supplied) at desired wall location. Note: Screw is to be located over wall stud or used with a wall anchor sized for a #8 x 1.25 self tapping screw. 3. Make sure power to alarm panel is disconnected. 4. Hang alarm panel using keyhole on panel back. Install second screw between tabs located on bottom of panel. 5. Mount the cord by placing the cord into the clamp as shown in Figure A. 6. Locate the clamp at the desired activation level and secure the clamp to the discharge pipe as shown in Figure A. Note: Do not install cord under hose clamp. 7. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. 8. Bring cable leads back to alarm device and wire according to Figure B. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements. Note: When used with a pump application, connect alarm to a circuit separate from the pump circuit. This allows the alarm to operate if the pump circuit fails. 9. Plug the panel in to apply power. The green "power on" light should come on. 10. Check installation by manually tipping the float. The horn and warning light should come on. 11. Move the horn silence switch to silence, the horn should silence while the red light stays on. 12. You must manually reset alarm after activation. Push horn button back to horn position and press "push to test" button. The light and horn should activate. 13. Test unit once per week to ensure proper operation. 14. Using the provided cable clasp, secure cord to outlet as shown in Figure C. Use existing receptacle faceplate screw and supplied washer.

Figure A

3.5 inch (9 cm) tether length

Figure B

low voltage screw terminals

(for connection to contacts with no external power source)

do NOT apply power power cord mounting tabs attach float switch here

Figure C

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

122

Instl. Instr. PN 1011978F ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® XT Alarm Installation Instructions

This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs. A "power on" light on the switch indicates power to the alarm panel.

TANK ALERT® XT ALARM

Q Voltage: 120 VAC, 50/60 Hz, 8.5 watts maximum (alarm condition) (circuit not supervised) Q Enclosure meets Type 3R water-tight standard. Q Automatic alarm reset, horn silence switch, and alarm test switch. Q Alarm horn sounds at 85 decibels at 10 feet (3 meters). Q Alarm system (when installed on separate circuit) operates even if pump circuit fails. Q Maximum line impedance for initiating device: 100 ohms. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q Three-year limited warranty.

OPTIONS

When ordered with the alarm, the system is available with:

Q alternate float switch models for high or low liquid level warning. Q auxiliary alarm contacts for easy attachment of remote devices: (circuit not supervised) 120 VAC, 5 amps max., 50/60 Hz Q premounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump power. Meets NEC standard for junction boxes. 20 amps, 120/230 VAC. Q 6 foot (1.8 meter) power cord with 120 VAC plug and liquid-tight connectors.

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

· · ·

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

INSTALL INSTRUCTIONS

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

123

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

INSTALLING THE FLOAT SWITCH

1. 2. Place the cord into the clamp as shown in Figure A. Locate the clamp at the desired activation level and secure the clamp to the discharge pipe as shown in see Figure A. Note: Do not install cord under hose clamp. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Wire cable leads directly into control device as shown in Figure B. Check installation. Allow system to cycle to insure proper operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

Figure A

3.

4. 5.

Figure B

INSTALLING THE ALARM

1. Mount alarm box using existing holes in back of box. To ensure water-tight seal, use screws and sealing washers included with alarm. Note: Screws are to be located over wall stud or used with a wall anchor sized for a #8 x 1.25 self tapping screw. 2. Determine "conduit-in" locations on alarm as shown in Figure B. Note: When used with a pump application, connect alarm to a circuit separate from the pump circuit. This allows alarm to continue to operate if the pump circuit fails. 3. Drill holes for conduit entry, taking care not to damage bosses inside alarm box. 4. Attach conduit.

If alarm includes premounted terminal block option, refer now to the Terminal Block Option Wiring Instructions.

5. Bring float switch cable through conduit and wire to terminal block positions 1 and 2 as shown in Figure B. 6. Wire power conductors to terminal block positions 3 and 4 and ground wire to ground termination post as shown in Figure B. Note: If terminal block option is used, attach ground wire as shown in Figure A of Terminal Block Option Wiring Instructions. 7. If remote device is used, connect wires as shown in Figure B using supplied wire nuts. 8. Attach alarm box cover using the four pre-installed screws. 9. Turn on power. Light on switch should come on. 10. Check installation by manually tipping the float. The horn and beacon should turn on. 11. Push silence switch to test silence feature. 12. Test unit once per week to insure proper operation.

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

124

Instl. Instr. PN 1016543F ©SJE-Rhombus Printed in USA 10/07

TANK ALERT® Duo Alarm Installation Instructions

This alarm system monitors two liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® Duo indoor/outdoor alarm monitors two alarm conditions. The alarm horn and red beacon activate in "flashing" mode when a high water condition occurs. The alarm horn and red beacon activate in "constant on" mode for alarm 2.

TANK ALERT® DUO ALARM

Q Voltage: 120 VAC, 50/60 Hz, 7 watts maximum (alarm condition) Q Enclosure meets Type 3R water-tight standard. Q Enclosure specifications: 6.5 x 4.5 x 3.0 inch (16.51 x 11.43 x 7.62 cm), indoor/ outdoor, weatherproof, thermoplastic Q Manual alarm reset, horn silence switch, and alarm test switch. Q Alarm horn sounds at 82 decibels at 10 feet (3 meters). Q High water alarm (flashes) float included. Q Alarm 2 input (constant on) float optional. Q Complete package includes standard SJE SignalMaster® control switch with 15 feet (4.57 meters) of cable and mounting clamp (high water alarm float). Q Three-year limited warranty.

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

127

INSTALLING THE FLOAT SWITCH

1. Determine desired activation level as shown in Figure A. Position float to activate prior to a threatening liquid level condition. To adust activation level, move mounting clamp up or down on discharge pipe. Place the cord into the clamp as shown in Figure B. Secure the clamp to the discharge pipe as shown in see Figure B. Note: Do not install cord under hose clamp. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

Figure A

2. 3.

4.

Figure B

INSTALL ALARM AND CONTROL SWITCH

1. 2. Determine mounting location for alarm panel. Mount alarm box using existing holes in back of box. To ensure a watertight seal, use screws and sealing washers included with alarm. Determine "conduit-in" locations on alarm (see Figure C). Drill holes for conduit entry, taking care not to damage bosses inside alarm box. Attach conduit. Use liquid-tight connectors if installing outdoors. Bring alarm 2 float wires through conduit and attach to terminal positions TB1-4 and TB1-5 as shown in Figure D. Bring high water alarm float wires through conduit and attach to terminal positions TB1-6 and TB1-7 as shown in Figure E. Note: If using VRS switch, do not connect to Alarm 1. Connect VRS to Alarm 2 input only. Bring alarm power wires through conduit and attach to terminal positions TB1-2 and TB1-3 as shown in Figure F. Attach ground to terminal position TB1-1 as shown in Figure F. Turn on power.

3. 4. 5. 6. 7.

FIGURE C

8.

9.

FIGURE D

FIGURE E

FIGURE F

TEST SYSTEM

1. Check installation by moving high alarm float upward. The system should indicate a flashing alarm condition. 2. Push test/normal/silence switch to "silence" horn (beacon should remain illuminated). 3. Lower high alarm float. 4. Place test/normal/silence switch to "normal" position. 5. Raise alarm 2 float switch. The system should indicate an alarm (solid) condition. 6. Lower alarm 2 float switch, the alarm should turn off.

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

128

©SJE-Rhombus Printed in USA 11/07 Instl. Instr. PN 1019950C

TANK ALERT® 4X Alarm Installation Instructions

This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other non-potable water applications. The Tank Alert® 4X indoor/outdoor alarm system can serve as a high or low level alarm depending on the float switch model used. The stainless steel alarm horn sounds and red beacon illuminates when a potentially threatening liquid level condition occurs.

TANK ALERT® 4X ALARM

Q Voltage: 120 VAC, 50/60 Hz Q NEMA 4X enclosure rated for indoor or outdoor use. Q Automatic alarm reset and alarm test/normal/silence switch. Q Alarm horn sounds at 88 decibels at 10 feet (3 meters). Q Alarm system (when installed on separate circuit) operates even if the pump circuit fails. Q Complete package includes standard Sensor Float® control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp. Q Three-year limited warranty.

OPTIONS

When ordered with the alarm, this system is available with:

Q alternate float switch models for high or low level warning. Q auxiliary alarm contacts (NO/NC) for easy attachment of remote devices: 120 VAC, 5 amps max., 50/60 Hz

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

129

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

INSTALLING THE FLOAT SWITCH*

1. 2. Place the float switch cord into the clamp as shown in Figure A. Locate the clamp at the desired activation level and secure the clamp to the discharge pipe as shown in Figure A. Note: Do not install cord under hose clamp. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Bring cable leads back to control device and wire according to Figure B. Check installation. Allow system to cycle to ensure proper operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

INSTALLING THE ALARM

1. 2. Determine mounting location for alarm panel. Determine "power-in" and "conduit-in" location on alarm panel. Note: When used with a pump application connect the alarm to a circuit separate from pump circuit. This allows the alarm to operate even if the pump circuit fails. Drill holes for power and control conduit entry. Mount panel using flange kit. Bring alarm float cable (or auxiliary contact wires**) through conduit and wire to terminal strip contacts labeled "alarm float" as shown in Figure B. Wire "power-in" conductors to terminal strip contacts marked L1 & N. If remote device is used, connect to terminal strip as shown on schematic located in plastic envelope inside alarm panel. Check installation by turning on power and manually tipping the alarm float. The alarm light and horn should indicate an alarm condition. Test unit periodically to ensure proper operation.

3.

3. 4. 5.

4. 5.

6. 7.

8.

Figure A

9.

Figure B

** The main control monitoring the alarm must have normally open dry auxiliary contacts available to operate this auxiliary alarm. NOTE: If this alarm is used as an auxiliary alarm device, power must be on at both the main control and this auxiliary alarm. Tipping the alarm float that runs to the main panel should activate this alarm.

*If this alarm is used as an auxiliary alarm, disregard the float switch mounting detail.

** Float or auxiliary contact wires

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

130

Instl. Instr. PN 1011977G ©SJE-Rhombus Printed in USA 10/07

Pump Switch Installation Instructions

SJE-Rhombus® wide angle pump switches are designed to provide automatic control of pumps in non-potable water and sewage applications. The SJE PumpMaster®, SJE PumpMaster® Plus and SJE PumpMaster® SPDT pump switches passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water applications.

SJE PUMPMASTER®

Mechanically activated pump switch for direct control of pumps in:

SJE PUMPMASTER® PLUS

Mechanically activated pump switch for direct control of pumps in:

SJE PUMPMASTER® SPDT

Mechanically activated pump switch for direct control of pumps in:

Q Sewage Q Non-potable Water Q Potable Water

U.S. Patent Nos. 5,087,801 & 5,142,108

Q Sewage Q Non-potable Water Q Potable Water

U.S. Patent Nos. 5,087,801 & 5,142,108

Q Sewage Q Non-potable Water Q Potable Water

U.S. Patent Nos. 5,087,801 & 5,142,108

tether length pumping range

3.5 6 10 14 18 22 24

min.

tether length pumping range

3.5 6 10 14 18 22 24

min.

tether length pumping range

3.5 6 10 14 18 22 24

min.

7 10 16 22 28 33 36

7 10 16 22 28 33 36

7 10 16 22 28 33 36

JUNIOR SUPER SINGLE®

Mercury activated pump switch for direct control of pumps in:

SUPER SINGLE®

Mercury activated pump and control switch for:

SJE AMPMASTER®

Mechanically activated pump switch for direct control of pumps in:

Q Sewage Q Non-potable Water Q Non-turbulent applications

U.S. Patent Nos. 4,429,854 & 4,572,934

Q Sewage Q Non-potable Water

Q Sewage Q Non-potable Water

U.S. Patent No. 4,302,641

U.S. Patent Nos. 5,087,801 & 5,142,108

tether length pumping range

3.5 6

min.

8 10 12 15 17

tether length pumping range

3.5 5

min.

7

9 13 15

tether length pumping range

min.

5 9

10 14 18 13 17 21

22

max.

6.5 8.5 11 13 14 17 19

6.5 7.5 8.5 11 12.513.5

24

· · · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts. The Junior Super Single® and Super Single® pump switches contain mercury and MUST be recycled or disposed of according to local, state, and federal codes.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

INSTALL INSTRUCTIONS

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

131

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

MOUNTING THE SWITCH

1. Determine the required cord tether length according to product specifications on the front page and as shown in Figure A. Place the cord into the clamp as shown in Figure B. Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown in Figure B. Note: Do not install cord under hose clamp. Tighten the hose clamp using screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Follow direct wire or piggy-back instructions for futher installation.

PIGGY-BACK PLUG INSTALL

Q Electrical outlet must not be located in pump chamber. Q Electrical outlet voltage, piggyback plug voltage, and pump voltage must match.

1. Follow steps 1 through 4 of "Mounting The Switch." 2. Insert switch's piggy-back plug into outlet. 3. Plug pump into piggy-back plug as shown in Figure A. 4. Check installation. Allow system to cycle to insure proper operation.

DIRECT WIRE INSTALL

1. 2. 3. Follow steps 1 through 4 of "Mounting The Switch." Wire switch as shown below. Check installation. Allow system to cycle to insure proper operation.

2. 3.

Figure B

4.

!

Normally Open and Normally Closed Normally Closed

WARNING: Tethering switches below minimum tether length can effect switch operation and will reduce the fatigue life of the cable.

5.

SJE PumpMaster® SPDT Only

Normally Open

Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

Figure A

switch plug pump plug

In 230 VAC installations, one side of the line going to the load is always HOT. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits. On SPDT Models, insulate unused red or black wires with wire nut. Wire can become electrically hot. Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down cable and entering the switch. Failure to guard against this may affect switch performance.

tether length

pumping range

Due to weight of cable, pumping range above horizontal is NOT equal to pumping range below horizontal. Use values published on front page as a guide. Pumping ranges are based on testing in non-turbulent conditions. Range may vary due to water temperature and cord shape. Note: As the tether length increases, so does the variance of the pumping range.

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

132

Instl. Instr. PN 1011973H ©SJE-Rhombus Printed in USA 10/07

Double Float® Master Pump Switch and Double Float® Pump Switch Installation Instructions

These mercury and mechanically activated, wide angle pump switches provide automatic control of pumps in non-potable water and sewage applications. They are well-suited for confined applications requiring a large pumping range. They are not sensitive to rotation or turbulence. The Double Float® and Double Float® Master pump switches consist of two floats. Each float contains a heavy-duty mercury or mechanical switch. The float assembly contains a holding relay which enables the floats to function in series. The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float® and Double Float® Master pump switches to operate relay control panels for larger pump applications.

DOUBLE FLOAT® MASTER PUMP SWITCH

Q Mechanically activated switch. Q Adjustable pumping range of 10 to 56 inches (25.4 to 142.2 cm) with increased pumping range up to 6 feet (1.8 meters) available. Q Three-year limited warranty.

DOUBLE FLOAT® PUMP SWITCH

Q Mercury activated switch. Q Adjustable pumping range of 1.75 to 48 inches (4.45 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available. Q Three-year limited warranty.

Patent Pending

Patent Pending

· · · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts. The Double Float® pump switch contains mercury and MUST be recycled or disposed of according to local, state, and Federal codes.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

Double Float® pump switch is a registered trademark of SJE-Rhombus® Controls.

133

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

MOUNTING THE SWITCHES

Failure to mount floats as outlined below may inhibit switch operation. 1. Determine pumping range for installation as shown in Figures B & C. 2. If floats are mounted less than 16 inches (40.6 cm) apart, mount floats at a 90o angle from each other as shown in Figure B. 3. Place cord into clamp as shown in Figures A and B. 4. Locate the clamp at the desired activation level and secure to discharge pipe as shown in Figure A. NOTE: Top and bottom floats are labeled. Ensure they are mounted per Figures B & C. 5. Tighten the hose clamp using a screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. 6. Mount the top float in a similar manner. Stow excess cable away from float operation. 7. Check installation. Allow system to cycle to insure proper operation. NOTE: All hose clamp components are made of 18-8 stainless steel. See your SJE-Rhombus supplier for replacements.

PIGGY-BACK PLUG INSTALL

Q Electrical outlet must not be located in pump chamber. Q Electrical outlet voltage, piggyback plug voltage, and pump voltage must match.

1. 2. Follow steps 1 through 6 of "Mounting The Switches." Insert 120 VAC piggy-back plug into 120 VAC outlet or 230 VAC piggy-back plug into 230 VAC outlet. Plug pump into piggy-back plug as shown in Figure B. Check installation. Allow system to cycle to insure proper operation.

DIRECT WIRE INSTALL

1. 2. Follow steps 1 through 6 of "Mounting The Switches." Wire switch as shown below. NOTE: Switch voltage and supply voltage must match to ensure proper operation of switches. Check installation. Allow system to cycle to insure proper operation.

3.

Figure C - Double Float® Master

3. 4.

Figure B - Double Float®

4"

4"

deactivation point (approximately 4 inches below mounting)

120 VAC

Figure A

If floats are mounted less than 16 inches (40.6 cm) apart, mount floats at a 90o angle from each other

230 VAC

INSTALL INSTRUCTIONS

In 230 VAC installations, one side of the line going to the load is always HOT. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits.

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

134

Instl. Instr. PN 1017691E ©SJE-Rhombus Printed in USA 10/07

SJE VerticalMaster® Pump Switch Installation Instructions

This mechanically activated pump switch is designed for direct control of pumps in non-potable water and sewage applications. It works well in applications with limited space such as: small sump chambers, effluent applications, and laundry trays, as well as in large tanks. The SJE VerticalMaster® pump switch is not sensitive to turbulence. It is available for pump down applications only.

SJE VERTICALMASTER® PUMP SWITCH

Q Mechanically activated. Q Heavy-duty contacts. Q Adjustable pumping range of .75 to 6.5 inches (2 to 17 cm). Q Three-year limited warranty. Q Maximum operating temperature 125oF.

U.S. Patent No. 5,155,311 Canadian Patent No. 2,060,748

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float and rod are free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

135

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

MOUNTING THE SWITCH

Warning: Do not install switch in direct line of incoming liquid. 1. Determine desired activation level and pumping range as shown in Figure A. Pumping range can be adjusted by moving the float stop up or down the rod. Insert hose clamp through slots in mounting bracket as shown in Figure B. Position hose clamp around discharge pipe with bracket gripping tabs against pipe. Cable should remain outside of hose clamp. Tighten the hose clamp securely. Secure pump cable and switch cable to discharge pipe as shown in Figure A.

PIGGY-BACK PLUG INSTALL

Q Electrical outlet must not be located in pump chamber. Q Electrical outlet voltage, piggyback plug voltage, and pump voltage must match.

1. 2. 3. 4. Follow steps 1 through 5 of "Mounting The Switch." Insert the switch's piggy-back plug into outlet. Plug pump into piggy-back plug as shown in Figure A. Check installation. Allow system to cycle to ensure proper operation.

DIRECT WIRE INSTALL

1. 2. 3. Follow steps 1 through 5 of "Mounting The Switch." Wire switch as shown below. Check installation. Allow system to cycle to insure proper operation.

2.

3.

4. 5.

Figure B

tighten hose clamp

insert hose clamp through mounting bracket slots In 230 VAC installations, one side of the line going to the load is always HOT. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits. Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down cable and entering the switch. Failure to guard against this may affect switch performance.

Figure A

switch plug pump plug keep switch cable outside hose clamp

Figure C

secure cables to discharge pipe

activation level pumping range

mounting bracket hose clamp

float guard lift rod stop pin lift rod float float stop

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

136

Instl. Instr. PN 1011981G ©SJE-Rhombus Printed in USA 10/07

Control Switch Installation Instructions

SJE-Rhombus® narrow angle control switches accurately monitor liquid levels in sewage, and non-potable water applications. These switches are designed to activate pump control panels and alarms. The SJE SignalMaster® and SJE SignalMaster® SPDT control switches passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water applications.

SJE SIGNALMASTER®

Q Mechanically activated. Q Control differential of 1.5 inches above or below horizontal. Q Not sensitive to rotation. Q Mounting options: mounting clamp or cable weight.

SJE SIGNALMASTER® SPDT

Q Mechanically activated. Q Control differential of 1.5 inches above or below horizontal. Q Not sensitive to rotation. Q Mounting options: mounting clamp or cable weight.

SENSOR FLOAT®

Q Mercury activated. Q Suitable for use with an intrinsically safe circuit.** Q Not sensitive to rotation. Q Mounting options: mounting clamp, internal or cable weight.

**Contact SJE-Rhombus for specific intrinsically safe applications.

SENSOR FLOAT® MINI

Q Q Q Q Q

Mercury activated. Narrow angle float switch in a small float housing. Suitable for use with an intrinsically safe circuit.** Not sensitive to rotation. Mounting options: mounting clamp or cable weight.

**Contact SJE-Rhombus for specific intrinsically safe applications.

· · · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts. The Sensor Float® and Sensor Float® Mini control switches contain mercury and MUST be recycled or disposed of according to local, state, and federal codes.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

137

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

MOUNTING THE SWITCH

WARNING: Do not install switch in direct line of incoming liquid. 1. Place the cord into the clamp as shown in Figure C. 2. Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown in Figures A and B. Note: Do not install cord under hose clamp. 3. Tighten the hose clamp using screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. 4. Wire switch as shown in Figure D. 5. Check installation. Allow system to cycle to insure proper operation. Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

CABLE WEIGHT

1. Determine desired activation level. 2. Suspend switch and cable weight at desired activation level as shown in Figure E. 3. Wire switch as shown in Figure D. 4. Check installation. Allow system to cycle to insure proper operation. To adjust cable weight tether length: 1. Release clip. 2. Adjust cable weight to desired position. 3. Lay switch cable in weight channel. 4. Align clip with weight channel and slide towards switch cable as shown in Figure E. 5. Snap clip snugly up to cable, moving clip to tightest possible position.

INTERNAL WEIGHT

SENSOR FLOAT® CONTROL SWITCH ONLY 1. Determine desired activation level as shown in Figures A & B. 2. Suspend switch 7 inches below desired activation level as shown in Figure F. Switch remains partially submerged during the "on" tipping action. Switch can be totally submerged and still continue to operate properly. 3. Wire switch as shown in Figure D. 4. Check installation. Allow system to cycle to insure proper operation.

Figure C

Figure B

Sensor Float® and Sensor Float® Mini

Figure A

SJE SignalMaster® and SJE Signal Master® SPDT

Figure E

Figure D

Normally Open and Normally Closed

SJE SignalMaster® SPDT Only

Normally Closed Normally Open

Figure F

In 230 VAC installations, one side of the line going to the load is always HOT. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits. On SPDT Models, insulate unused red or black wires with wire nut. Wire can become electrically hot. Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down cable and entering the switch. Failure to guard against this may affect switch performance.

7 inches (18 cm)

INSTALL INSTRUCTIONS

approximate activation level

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

138

Instl. Instr. PN 1011974H ©SJE-Rhombus Printed in USA 10/07

SJE MilliAmpMasterTM Control Switch and SJE MicroMaster® AC/DC Pump Switch Installation Instructions

These mechanically activated switches provide automatic control for AC and DC applications in potable water, water, and sewage applications. The SJE MilliAmpMasterTM control switch and SJE MicroMaster® AC/DC pump switch passed NSF Standard 61 protocol by an approved Water Quality Association laboratory for use in potable water applications.

SJE MILLIAMPMASTERTM (narrow angle version)

Mechanically activated control switch for:

SJE MILLIAMPMASTERTM (wide angle version)

Mechanically activated control switch for:

Q Q Q Q Q

Low current, non-arcing applications down to 0.160 mA at 125 VAC Potable Water Water Sewage application Control differential of 1.5 inches above or below horizontal with 3.5 inch tether.

Q Q Q Q

Low current, non-arcing applications down to 0.160 mA at 125 VAC Potable Water Water Sewage application

tether length

(inches)

3.5

min.

6 11

9 15

12 21

15 28

18 31

22 36

SJE MICROMASTER® AC/DC

Mechanically activated pump and control switch for:

pumping range

(inches)

8

Q Q Q Q Q

tether length

(inches)

Battery backup pumps Arcing loads Potable Water Water Sewage applications

3.5

min.

6 11

9 15

12 21

15 28

18 31

22 36

pumping range

(inches)

8

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS ® ; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

INSTALL INSTRUCTIONS

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJERHOMBUS ® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

139

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

MOUNTING THE SWITCH

1. Determine the required cord tether length according to product specifications on the front page and as shown in Figure A, B & C. Place the cord into the clamp as shown as shown in Figure D. Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown in Figure D. Note: Do not install cord under hose clamp. Tighten the hose clamp using screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Wire switch as shown in the Wiring Diagrams. Check installation. Allow system to cycle to insure proper operation.

Figure B

Battery Backup Installation

DC Wiring Diagram Normally Open and Normally Closed

2. 3.

4.

Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down cable and entering the switch. Failure to guard against this may affect switch performance.

5. 6.

Figure C

SJE MilliAmpMasterTM (narrow angle version)

AC Wiring Diagram Normally Open and Normally Closed

Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

Figure A

tether length

In 230 VAC installations, one side of the line going to the load is always HOT. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits. Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down cable and entering the switch. Failure to guard against this may affect switch performance.

Figure D

pumping range

INSTALL INSTRUCTIONS

Due to weight of cable, pumping range above horizontal is NOT equal to pumping range below horizontal. Use values published on front page as a guide. Pumping ranges are based on testing in non-turbulent conditions. Range may vary due to water temperature and cord shape. Note: As the tether length increases, so does the variance of the pumping range.

!

WARNING: Tethering switches below minimum tether length can affect switch operation and will reduce the fatigue life of the cable.

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

140

Instl. Instr. PN 1011976J ©SJE-Rhombus Printed in USA 10/07

Junction Box Installation Instructions

These junction boxes provide a convenient location to connect all wiring required for a typical pumping station, on-site system or other electrical installation.

JUNCTION BOXES

Q NEMA 4X enclosure rated for outdoor use. Q External mounting feet included. Q Three-year limited warranty.

· ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable(s) has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

141

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

INSTALLING THE JUNCTION BOX

1. 2. 3. 4. 5. Mount junction box in desired location. Caution: Junction boxes are not meant to be installed in the riser where flooding may occur. Install wiring. See Figure A and B for potential cord placement for simplex and duplex systems. Seal the hub as required by local and national electrical code to prevent moisture from entering junction box. Verify cover gasket is in place. Install cover.

Potential cord entry locations for Simplex and Duplex systems Figure A

Pump Power Cord

Figure B

Pump 1 Power Cord Pump 2 Power Cord

Alarm Float

Lag/Alarm Float

Start Float

SIMPLEX SYSTEM

Lead Float

DUPLEX SYSTEM

Stop Float

Stop Float

1 1/2"

Wiring to Control Panel

2"

Wiring to Control Panel

INSTALL INSTRUCTIONS

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

142

Instl. Instr. PN 1011984H ©SJE-Rhombus Printed in USA 10/07

Accessories Installation Instructions

Cord Seal, Cable Weight, Cable Clamp Assembly, and Float Bracket.

CORD SEAL

Provides strain relief and a liquid-tight seal.

CABLE WEIGHT

Provides an accurate pivot point for suspended float switches.

Q Seals 1-3 cables in 2" terminal adapters Q 2 PVC plugs included (for unused cable positions) Q Ground wire

U.S. Patent 5,306,885

Q Gripper teeth on clip and weight channel securely lock float cable into place Q Cable Weight can be adjusted without the use of tools

CABLE CLAMP ASSEMBLY

Provides cable anchor point and strain relief. Secures cable in vertical direction.

FLOAT BRACKET

Provides convenient installation of float switches.

Q

For use with 18/16 gauge, 14 gauge, & 12 gauge cable Q Mounting clamp: ABS Nylon blend Q Hose clamp: highly corrosion resistant stainless steel

Q Six Float Bracket supports 1-6 floats Q Four Float Bracket supports 1-4 floats Q Can be directly mounted to wall or used with wall mounting device Q Provides convenient location to stow excess float cord Q Supplied with cord strain relief connectors

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float is free to move and operate the pump or alarm. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®.

INSTALL INSTRUCTIONS

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

143

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.

For detailed specifications on this product, or for the complete line of SJE-Rhombus® panel, alarm, and switch products, visit our web-site at www.sjerhombus.com.

CORD SEAL INSTALL

1. Pass the cables through the 2" terminal adaptor. 2. With the three position cord seal, route cables through the seal, leaving adequate cable to work with. NOTE: If three cords are not used, plug open position(s) in the cord seal with the PVC plug(s) provided. 3. Insert the cord seal into the terminal adaptor and tighten hex nut until adequate strain relief is achieved. 4. Gather all ground wires, including ground conductor on the cord seal and secure to ground terminal.

FLOAT BRACKET INSTALL

1. 2. Drill holes in mounting surface 1-5/16 inches apart. Install float bracket mounting device as shown in Figure E. NOTE: Use stainless steel fasteners appropriate for the mounting surface. Determine float switch cord length to hang into tank to achieve proper activation level. Install float switch cords to float bracket using strain relief connectors as shown in Figure F. Install float bracket into float bracket mounting device while stowing excess cable as shown in Figure F.

Figure C

float switch cable weight tether length*

3. 4. 5.

*Control Switches: Recommended tether length is 4 inches (10 cm) *Pump Switches: Minimum recommended tether length is 3.5 inches (9 cm)

CABLE WEIGHT INSTALL

1. Lay cable in weight as shown in Figure B. 2. Align clip with weight groove and slide clip towards cable as shown in Figure B. Snap clip snugly up to cable and manually force clip to tightest possible position. 3. See Figure C for proper tether length.

Figure D

Figure A

CABLE CLAMP INSTALL

1. 2. 3. Determine the required cord tether length according to product specifications. Place the cord into the clamp as shown as shown in Figure D. Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown in Figure D. Note: Do not install cord under hose clamp. Tighten the hose clamp using screwdriver. Over tightening may result in damage to the plastic clamp. Make sure the float cable is not allowed to touch the excess hose clamp band during operation. Wire switch as shown in the Wiring Diagrams. Check installation. Allow system to cycle to insure proper operation.

Figure 3 Figure E

Figure B

4.

Figure F

5. 6.

strain relief connector

INSTALL INSTRUCTIONS

Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

144

Instl. Instr. PN 1011985H ©SJE-Rhombus Printed in USA 10/07

Vertical Reed Switch Installation Instructions

ELECTRICAL SHOCK HAZARD

Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.

EXPLOSION OR FIRE HAZARD

Do not use this product with flammable liquids. Do not install in hazardous locations as defined by National Electrical Code, ANSI/NFPA 70.

Failure to follow these precautions could result in serious injury or death. Keep these instructions with warranty after installation.

Q Install in accordance with National Electric Code, ANSI/NFPA 70 to prevent moisture from entering or accumulating within boxes, conduit

bodies, fittings, float housing, or cable.

ALARM INSTALL

1. Mount alarm according to the installation instructions provided with the alarm.

Figure A

control switch

MOUNTING THE SWITCH

Warning: Do not install switch in direct line of incoming liquid. 1. 2. Place the clamp into the switch housing as shown in Figure A. Locate clamp at desired activation level and secure the clamp to the discharge pipe as shown in Figure A. Note: Do not install cord under hose clamp. Tighten the hose clamp using screwdriver. Over tightening may result in damage to the switch housing. Check installation. Allow system to cycle to insure proper operation. alarm activation level

3. 4.

Note: All hose clamp components are made of 18-8 stainless steel material. See your SJE-Rhombus® supplier for replacements.

· · ·

PREVENTATIVE MAINTENANCE

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected. Periodically check to see that the float and rod are free to move and operate the switch. Use only SJE-Rhombus® replacement parts.

SJE-RHOMBUS® THREE-YEAR LIMITED WARRANTY

SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for three years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-RHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. THIS EXPRESS WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENT. SJE-RHOMBUS® MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO THE MOTOR START KIT. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJE-RHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/ or modified without prior authorization from SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

INSTALL INSTRUCTIONS

145

NOTES: _______________________________________________________________________________________________

_______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________ _______________________________________________________________________________________________________

INSTALL INSTRUCTIONS

_______________________________________________________________________________________________________

22650 County Highway 6 Q P.O. Box 1708 Q Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) Q Phone: 218-847-1317 Q Fax: 218-847-4617 Q E-mail: [email protected]

146

©SJE-Rhombus Printed in USA Rev 10/07 Inst. Instr. PN1019436B

Engineered Custom Systems

SJE-Rhombus® designs and builds custom solutions for your control, pumping and monitoring systems. Built to your individual specifications, our services encompass functional specification development, design and configuration, thorough documentation, system assembly, and exceptional customer support. We have a strong team of dedicated engineers and technicians that will prepare comprehensive quotes and detailed submittal packages tailored to your requirements. From panels utilizing inventoried components to deliver competitive quotes and lead times, to complex system integration, SJE-Rhombus has the knowledge, versatility and expertise to deliver what you need, when you need it.

Typical Applications Lift Stations Grinder Stations Recirculation Systems Pressure Booster Systems Hydropneumatic Systems Aerobic Treatment Well Pump Control

Leachate Pump Control Condensate Return Irrigation Systems Process Control Storm Water Dewatering

Available Features Variable Frequency Drives (VFDs) Telemetry/SCADA Reduced Voltage Starters Service Entrance Rating (UL) Programmable Logic Controllers (PLCs) Battery-Backed Alarm Systems Multiple Pump Control Applications User Specified Components SJE-Rhombus is a UL Listed panel shop. UL 508A Listing for industrial control panels or UL 698A Listing for enclosed industrial control panels with circuit extensions to a Class I, Division I, Group C, D hazardous location.

See what SJE-Rhombus can do for you! Get a free copy of the Engineered Custom Controls Brochure or download it free in PDF format at www.sjerhombus.com. 1-800-RHOMBUS (1-800-746-6287)

Proud to be a member of these industry associations:

22650 County Highway 6, PO Box 1708 Detroit Lakes, MN 56502-1708 USA 1-888-DIAL-SJE (1-888-342-5753) Ph: 218-847-1317 Fax: 218-847-4617

www.sjerhombus.com

P/N 1011989G ©SJE-Rhombus Printed in USA 09/07

Information

Catalog Cover 2008 Setup.qxp

148 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

8120