Fabricated Steel FEMA 361 Grille Chevron Blade

Application and Design

FSG-801 is a severe duty fabricated steel grille designed to protect exterior wall penetrations on FEMA 320 or 361 compliant storm shelters or safe rooms. Most frequently FSG-801 is installed in front of wall louvers, but may be installed in front of any exterior wall penetration that requires protection. Design incorporates inverted V style blades which lend high free area and very little airflow resistance while providing maximum protection against extremely high wind loads and wind-borne debris. FSG-801 withstands wind loads up to 248 PSF and complies with FEMA 320 and 361 storm shelter and safe room standards (ICC 500) for debris impact, which simulates a 15 lb. 2 x 4 traveling at 100 MPH. Model FSG-801 is a UL Listed wind-storm rated assembly allowing the design professional to select and apply with confidence.

Shown as head & sill mount configuration

Standard Construction

Mounting . . . . . .Cantilever style Frame . . . . . . . .8 in. x 0.25 in. hot rolled steel, frame flanges located at top and bottom or sides · Single section assembly customer specify flange configuration · Multiple section wide assembly flanges located at top and bottom only · Multiple section high assembly flanges located at sides only Blades . . . . . . . .Inverted V Style, 0.25 in. hot rolled steel Construction . . .Welded Screen . . . . . . . .½ in. x 18 gauge expanded stainless steel Finish . . . . . . . . .Liquid urethane paint, 24 standard colors available, (1 yr. finish warranty) Minimum Size . .12 in. W x 12 in. H Maximum Single Section Size . . . . . . . . . . . . . .96 in. W x 76 in. H or 76 in. W x 120 in. H Maximum Overall Width . . . . . . . . . . . . . .Unlimited, may only be 1 section high Maximum Overall Height . . . . . . . . . . . . . . Unlimited, may only be 1 section wide Approx. wt. . . . .40 lbs./sq. ft. (removeable lifting lugs provided)

Options (at additional cost)

· Flush/recessed mounting configuration · Deep sleeve · Liquid urethane finish (one-year warranty) · Powder paint (no warranty)

*Width and height dimensions furnished actual size. Actual size does not include top and bottom flanges or side flanges.

Shown as jamb mount configuration

PERFORMANCE DATA

Free Area Chart (Sq. ft.)

Louver Height Inches 12 18 24 30 36 42 48 54 60 66 72 76 84 90 96 102 108 116 120 Louver Width Inches 12 0.36 0.52 0.77 1.02 1.27 1.52 1.68 1.93 2.18 2.43 2.67 2.84 3.09 3.33 3.58 3.83 4.08 4.33 4.49 24 0.81 1.19 1.75 2.31 2.87 3.43 3.80 4.37 4.93 5.49 6.05 6.42 6.98 7.55 8.11 8.67 9.23 9.79 10.17 30 1.04 1.52 2.23 2.95 3.67 4.39 4.87 5.58 6.30 7.02 7.74 8.22 8.93 9.65 10.37 11.09 11.81 12.52 13.00 36 1.26 1.85 2.72 3.60 4.47 5.35 5.93 6.80 7.68 8.55 9.43 10.01 10.88 11.76 12.63 13.51 14.38 15.26 15.84 42 1.49 2.18 3.21 4.24 5.27 6.30 6.99 8.02 9.05 10.08 11.11 11.80 12.83 13.86 14.90 15.93 16.96 17.99 18.68 48 1.72 2.51 3.70 4.88 6.07 7.26 8.05 9.24 10.43 11.61 12.80 13.59 14.78 15.97 17.16 18.35 19.53 20.72 21.51 54 1.94 2.84 4.18 5.53 6.87 8.22 9.11 10.46 11.80 13.15 14.49 15.39 16.73 18.08 19.42 20.76 22.11 23.45 24.35 60 2.17 3.17 4.67 6.17 7.67 9.17 10.18 11.68 13.18 14.68 16.18 17.18 18.68 20.18 21.68 23.18 24.68 26.19 27.19 66 2.40 3.50 5.16 6.82 8.47 10.13 11.24 12.89 14.55 16.21 17.87 18.97 20.63 22.29 23.95 25.60 27.26 28.92 30.02 72 2.62 3.83 5.65 7.46 9.27 11.09 12.30 14.11 15.93 17.74 19.56 20.77 22.58 24.39 26.21 28.02 29.84 31.65 32.86 76 2.77 4.05 5.97 7.89 9.81 11.73 13.01 14.93 16.84 18.76 20.68 21.96 23.88 25.80 27.72 29.63 31.55 33.47 34.75 84 3.08 4.49 6.62 8.75 10.88 13.00 14.42 16.55 18.68 20.80 22.93 24.35 90 3.30 4.82 7.11 9.39 11.68 13.96 15.48 17.77 20.05 22.34 24.62 26.14

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

96 3.53 5.16 7.60 10.04 12.48 14.92 16.55 18.99 21.43 23.87 26.31 27.94

102 3.75 5.49 8.08 10.68 13.28 15.88 17.61 20.20 22.80 25.40 28.00 29.73

108 3.98 5.82 8.57 11.33 14.08 16.83 18.67 21.42 24.18 26.93 29.69 31.52

116 4.28 6.26 9.22 12.18 15.15 18.11 20.08 23.05 26.01 28.97 31.94 33.91

120 4.43 6.48 9.55 12.61 15.68 18.75 20.79 23.86 26.93 29.99 33.06 35.11

Airflow Resistance

(Standard Air - .075 lb/ft3)

Model FSG-801 resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size.

INSTALLATION DETAILS JAMB MOUNT

Maximum Size and Installation Information

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

Maximum single section size for model FSG-801 is 96 in. W x 76 in. H or 76 in W x 120 in H when applying the jamb mount configuration. Larger opening sizes may be constructed of multiple FSG-801 panels high. When installed in accordance with the methods shown within the attached submittal data sheets model FSG-801 will withstand wind-loads up to 248 PSF and will comply with FEMA 320 and 361 storm shelter and safe room standards for debris impact (ICC 500).

PRODUCT DETAILS JAMB MOUNT

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

Anchor/Fastener Requirements-Jamb Mount

Substrate Type Concrete (min. 3000 psi) CMU (grout-filled, min. 1500 psi) Steel (min. Fy 65,000 psi) Anchor/ Fastener Type 1/2 in. Red Head SS LDT 1/2 in. Red Head SS LDT 1/2 in. SS Bolt (tap or nut) Min. Edge Min. Distance Embedment 3.25 in. 3.25 in. 1.00 in. 2.5 in. 2.5 in. 0.25 in.

· Anchors or fasteners into building substrate are not supplied by Greenheck. · Anchors or fasteners into building substrate are to be located on 12 in. centers or 9 in. centers if panels width exceds 84 in.

INSTALLATION DETAILS HEAD & SILL MOUNT

Maximum Size and Installation Information

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

Maximum single section size for model FSG-801 is 96 in W x 76 in. H or 76 in W x 120 in H when applying the head and sill mount configuration. Larger opening sizes may be constructed of multiple FSG-801 panels wide. When installed in accordance with the methods shown within the attached submittal data sheets model FSG-801 will withstand wind-loads up to 248 PSF and will comply with FEMA 320 and 361 storm shelter and safe room standards for debris impact (ICC 500).

PRODUCT DETAILS HEAD & SILL MOUNT

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

Anchor/Fastener Requirements-Head & Sill Mount

Substrate Type Concrete (min. 3000 psi) CMU (grout-filled, min. 1500 psi) Steel (min. Fy 65,000 psi) Anchor/ Fastener Type 3/4 in. SS Thread Rod in Red Head C6 Epoxy 3/4 in. SS Thru Bolt & Plate Washer 1/2 in. SS Bolt (tap or nut) Min. Edge Distance 3.25 in. 3.25 in. 1.00 in. Min. Embedment 6.75 in. All 0.25 in.

· Anchors or fasteners into building substrate are not supplied by Greenheck. · Anchors or fasteners into building substrate are to be located on 24 in. centers or 18 in. centers if both width is greater than 60 in. AND height is greater than 76 in.

OPTIONAL FLUSH/RECESSED MOUNT

Size Restrictions and Installation Details

FEMA 361 Grille Chevron Blade Fabricated Steel

FSG-801

Greenheck can also offer the FSG-801 grille in a recessed/flush mounting configuration should the standard cantilever style mount configuration not be suitable. The size restrictions and/or installation details referenced herein that pertain to the cantilever mounting configuration(s) are applicable for the recessed/flush mounting configuration. If desired, Greenheck can also factory install nearly any Greenheck louver model within the flush/recessed mount optional deep sleeve.

®

FSG-801 November 2010, Rev. 3 Copyright © 2010 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.