Electric Motors

Technical catalogue

Low-voltage squirrel-cage motors

3.1e

2002

All technical data, outputs, dimensions and weights stated in this catalogue are subject to change without prior notice. The illustrations are not binding.

C. . . .t . . . o.n.t.e.n . .s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

Standards and regulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Conditions of installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Permissible temperature rises . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Mechanical design Degrees of protection . . Mounting arrangements Terminal boxes . . . . . . . Bearings . . . . . . . . . . . . Belt drive . . . . . . . . . . . Cooling. . . . . . . . . . . . . Vibration. . . . . . . . . . . . Noise . . . . . . . . . . . . . . Brake motors. . . . . . . . . Single-phase motors . . . Spare parts . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

10 11 12 13 14 15 15 16 17 18 19

Electrical design Rated voltage . . . . . . . . . . . . . Rated frequency . . . . . . . . . . . Rated current . . . . . . . . . . . . . Rated torque . . . . . . . . . . . . . . Output . . . . . . . . . . . . . . . . . . Overload . . . . . . . . . . . . . . . . . Brake motors. . . . . . . . . . . . . . Connection diagrams. . . . . . . . Insulation and temperature rise Starting rate . . . . . . . . . . . . . . Thermal protection . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

. . . . . . . . . . .

22 22 22 23 23 23 23 24 26 27 28

Order data Motors for normal duty and conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Special service duties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

3

4

S .a . . a . d . .. . .. . u.. ... . . . .t . .n.d. . r . . s. .a n.d. .r e.g . . l a.t i o.n.s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

CSA Approval Canadien Standards Association

5

The motors comply with the relevant standards and regulations, especially:

Títle IEC Electrical General stipulations for electrical machines Rotating electrical machines: methods for determining losses and efficiency using tests Terminal markings and direction of rotation of rotating electrical machines Starting performance Standard voltages Insulating materials Mechanical Dimensions and output ratings Mounting dimensions and re- 60072 lationship frame sizes-output ratings, IM B3 Mounting dimensions and re- 60072 lationship frame sizes-output ratings, IM B5 Mounting dimensions and re- 60072 lationship frame sizes-output ratings, IM B14 Cylindrical shaft ends for electric motors Degrees of protection Methods of cooling Mounting arrangements Noise limits Mechanical vibration Mounting flanges Tolerances of mounting and shaft extensions Classification of environmental conditions Mechanical vibration; balancing ISO 8821 DIN ISO 8821 600721-2-1 60034-5 60034-6 60034-7 60034-9 60034-14 EN 60034-5 EN 60034-6 EN 60034-7 EN 60034-9 DIN IEC60034-5 DIN EN 60034-6 DIN EN 60034-7 DIN EN 60034-9 DIN 42948 DIN 42955 CEI EN 60034-5 CEI EN 60034-6 CEI EN 60034-7 CEI EN 60034-9 UNEL 13501 UNEL 13501/ 13502 DIN IEC 60721-2-1 CEI 75-1 4999-20 EN60034-5 20111-5 4999-21 4999-22 51-117 4999-51 51-119 EN 60034-6 EN 60034-7 EN 60034-9 EN 60034-14 60072 HD 231 DIN 784-3 UNEL 13502 4999-10 51-111 HD 231 DIN 42677-1 UNEL 13118 4999-10 51-105 51-110 51-104 20106-2-IC-80 HD 231 DIN 42677-1 UNEL 13117 20106-2-74 HD 231 DIN 42673-1 UNEL 13113 4999-10 51-105 51-110 51-104 20106-1/26 1980 60072 UNEL 13113 60034-12 60038 60085 EN 60034-12 DIN EN 60034-12 CEI EN 60034-12 4999-112 HD 472 S1 DIN IEC 60038 DIN IEC 60085 CEI 8-6 CEI 15-26 UNE EN 60034-12 60034-8 HD 53 8 S4 DIN VDE 0530-8 CEI 2-8 4999-3 51-118 20113-8-96 60034-2 HD 53 2 DIN EN 60034-2 CEI EN 60034-2 60034-1 EN 60034-1 DIN EN 60034-1 CEI EN 60034-1 4999-1 51-200 UNE EN 60034-1 UNE EN 60034-2 4999-69 51-111 4999-34 51-112 EU CENELEC D DIN/VDE I CEI/UNEL GB BS F NFC E UNE

EN60034-14 DIN EN 60034-14 CEI EN 60034-14 4999-50 51-111

6

C. . . . . o.n.d.i.t.i.o.n . . .o.f. .i.n.s t . .l l a.t.i o.n. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .s . . .. a ... .. .

The motors are designed for operation at altitudes 1000 m above sea-level and at ambient temperatures of up to 40° C. Exceptions are indicated on the rating plate.

Permissible temperature rises to various standards

Standard/Regulation Temperature of coolant °C VDE 0530 part 1 International IEC 34-1 Britain BS 2613 Canada CSA USA NEMA and ANSI Italy CEI Sweden SEN Norway NEK Belgium NBN France NF Switzerland SEV India IS Germanischer Lloyd 1) American Bureau of Shipping 1) Bureau Veritas 1) Norske Veritas

1)

Permissible temperature rise in K (measured by resistance method) Temperature class B F H 80 80 80 80 80 80 80 80 80 80 80 80 75 70 70 70 70 70 70 75 105 105 105 105 105 105 105 105 105 105 105 90 95 100 90 2) 90 90 90 95 125 125

40 40 40 40 40 40 40 40 40 40 40 40 45 50 45 45 45

1)

on request

Lloyds Register 1) Registro Italiano Navale Korean Register

1)

45 50 45

China Classification Society 1)

1)

Classification societies for marine motors Only with special approval

2)

7

The motors conform to degree of protection IP 55 to IEC 60034-5. Higher protection on request. The standard design for horizontal mounting is suitable for indoor and protected outdoor installation, climate group MODERATE (see page 15) (temperature of coolant -20° to +40° C). For unprotected outdoor installation or severe climatic conditions (moisture category wet, climate group WORLDWIDE, extremely dusty site conditions, aggressive industrial atmosphere, danger of storm rain and coastal climate, danger of attack by termites, etc.), as well as vertical mounting, special protective measures are recommended, such as: · · · · · · Protective cowl (for vertical shaft-down motors) For vertical shaft-up motors additional bearing seal and flange drainage Special paint finish Treatment of winding with protective moisture-proof varnish Anti-condensation heating (possibly winding heating) Condensation drain holes

The special measures to be applied have to be agreed with the factory once the conditions of installation have been settled.

The corresponding conditions of installation have to be clearly indicated in the order.

8

Tolerances

For industrial motors to EN 60034-1, certain tolerances must be allowed on guaranteed values, taking into consideration the necessary tolerances for the manufacture of such motors and the materials used. The standard includes the following remarks: 1. It is not intended that guarantees necessarily have to be given for all or any of the items involved. Quotations including guaranteed values subject to tolerances should say so, and the tolerances should be in accordance with the table. 2. Attention is drawn to the different interpretation of the term guarantee. In some countries a distinction is made between guaranteed values and typical or declared values. 3. Where a tolerance is stated in only one direction, the value is not limited in the other direction. Values for Efficiency () (by indirect determination) Power factor (cos ) Slip (s) (at rated load and at working temperature) Breakaway starting current (IA) (in the starting circuit envisaged) Breakaway torque (MA) Pull-up torque (MS) Pull-out torque (MK) Moment of inertia (J) Tolerance - 0.15 (1 - ) at PN 50 kW - 0.1 (1 - ) at PN > 50 kW 1 - cos 6 , minimum 0.02, maximum 0.07

± 20 % of the guaranteed slip at PN 1 kW ± 30 % of the guaranteed slip at PN < 1 kW + 20 % of the guaranteed starting current (no lower limit) - 15 % and + 25 % of the guaranteed breakaway torque (+ 25 % may be exceeded by agreement) - 15 % of the guaranteed value - 10 % of the guaranteed value (after allowing for this tolerance, MK/MN not less than 1.6) ± 10 % of the guaranteed value

9

M . c . .n .. a . . . .. . . . .e . .h.a . .i c. . l . d.e.s.i g.n. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Degrees of protection

Degrees of protection for mechanical machines are designated in accordance with IEC 60034-5 by the letters IP and two characteristic numerals.

First numeral: Protection against contact and ingress of foreign bodies IP 0 1 Description No special protection Protection against solid foreign bodies larger than 50 mm (Example: inadvertent contact with the hand) Protection against solid foreign bodies larger than 12 mm (Example: inadvertent contact with the fingers) Protection against solid foreign bodies larger than 2.5 mm (Example: Wires, tools) Protection against solid foreign bodies larger than 1 mm (Example: Wires, bands) Protection against dust (harmful deposits of dust)

Second numeral: Protection against ingress of water IP 0 1 Description No special protection Protection against vertically falling water drops (condensation)

2

2

Protection against dropping water when inclined by up to 15°

3

3

Protection against waterspray at up to 60° from vertical

4

4

Protection against water splashed from any direction

5

5

Protection against water projected by a nozzle from any direction Protection against heavy seas or water projected in powerful jets

6

Complete protection against dust. Is not described for electrical machines to IEC 34-5.

6

7

Protection when submerged between 0.15 and 1 m

8

Protection when continuously submerged in water at conditions agreed between the manufacturer and the user.

10

Mounting arrangements

Mounting arrangements for rotating electrical machines are designated according to IEC 60034-7, Code I (in brackets Code II). Our motors are available with the mounting arrangements listed below, depending on design and frame size. Motors with aluminium frame are equipped with removable feet that allow easy change of mounting arrangement.

Foot mounting

IM B3 (IM 1001)

Flange mounting

IM B5 (IM 3001) Flange type A to DIN 42 948 at drive end

Motors without endshield

IM B9 (IM 9101) without endshield and without ball bearings on drive end

IM B6 (IM 1051)

IM V1 (IM 3011)

Flange type A to DIN 42 948 at drive end

IM V8 (IM 9111)

without endshield and without ball bearings on drive end

IM B7 (IM 1061)

IM V3 (IM 3031)

Flange type A to DIN 42 948 at drive end

IM V9 (IM 9131)

without endshield and without ball bearings on drive end

IM B8 (IM 1071)

IM B35 (IM 2001)

Flange type A to DIN 42 948 at drive end

IM B15 (IM 1201)

without endshield and without ball bearings on drive end

IM V5 (IM 1011)

IM B14 (IM 3601)

Flange type C to DIN 42 948 at drive end

IM V6 (IM 1031)

IM V18 (IM 3611)

Flange type C to DIN 42 948 at drive end

IM B34 (IM 2101)

Flange type C to DIN 42 948 at drive end

IM V19 (IM 3631)

Flange type C to DIN 42 948 at drive end

It is essential to state the desired mounting arrangement when ordering, as the constructive design depends partly on the mounting arrangement.

11

Terminal boxes

The location of the terminal box in standard design is on top; on the right or on the left are possible. Direction of cable entries For motors with mountings IM B6, IM B7, IM B8, IM V5, IM V6 the location of the terminal box is related to an IM B3 mounting. The position of the entry openings can be adjusted to suit the existing connection facilities by turning through 90°. Should special accessories be used (temperature detectors, anti-condensation heating, etc.) please enquire. For motors in standard design, the cable gland does not belong to our scope of delivery. For plastic terminal boxes, only plastic glands may be used (shock protection). When using screened leads, a metal terminal box is required.

Frame size

Degree of protection

Thread for cable entry 1) Pg 2 x Pg 11 1 x Pg 13.5 / 1 x Pg 16 1 x Pg 13.5 / 1 x Pg 16 2 x Pg 21 Metric 2) 1 x M20 1 x M25 1 x M25 2 x M32

56 - 71 80 - 100 112 132

IP IP IP IP

55 55 55 55

Connection for Max. cable temperature section detector Pg Metric mm 2 2,5 2,5 4 4 -

Terminal thread

Max. external cable diam. mm 12 16 16 20

M4 M4 M5 M5

1) 2)

Pg thread to DIN 40 430 Pitch 1.5

12

Bearings

Classification of bearings (standard design) Ball bearings to ISO15 (DIN 625) Frame size Drive end Non-drive end

56 63 71 80 90 100 112 132

6201-2Z 6202-2Z 6202-2Z 6204-2Z 6205-2Z 6206-2Z 6206-2Z 6208-2Z C3

6201-2Z 6202-2Z 6202-2Z 6204-2Z 6205-2Z 6206-2Z 6206-2Z 6208-2Z C3

Bearing arrangement

Frame size 56 - 132 Bearing drive end Non-locating bearing Bearing non-drive end Non-locating bearing Spring-loaded Non-drive end

Maximum permissible axial forces without additional radial forces *

Frame size 3000 min -1 kN 0.16 0.19 0.23 0.32 0.34 0.48 0.48 0.6 Horizontal shaft 1500 1000 min -1 min -1 kN kN 0.21 0.26 0.33 0.44 0.48 0.68 0.68 0.9 0.33 0.46 0.49 0.70 0.70 1.1 750 min -1 kN 0.37 0.50 0.54 0.77 0.77 1.3 Vertical shaft - force upwards 3000 1500 1000 750 min -1 min -1 min -1 min -1 kN kN kN kN 0.18 0.21 0.26 0.34 0.38 0.54 0.56 1.0 0.22 0.28 0.35 0.47 0.47 0.74 0.75 1.3 0.36 0.48 0.53 0.76 0.77 1.5 0.39 0.53 0.58 0.83 0.84 1.9 Vertical shaft - force downwards 3000 1500 1000 750 min -1 min -1 min -1 min -1 kN kN kN kN 0.15 0.17 0.21 0.29 0.31 0.43 0.40 0.5 0.19 0.24 0.30 0.41 0.44 0.62 0.60 0.75 0.31 0.43 0.46 0.64 0.62 0.75 0.34 0.47 0.51 0.71 0.69 1.05

56 63 71 80 90 100 112 132

Values for 50 Hz. For service on 60 Hz, reduce values by 10% * Consult according to direction of force

13

Permissible radial forces

without additional axial force (Ball bearings)

Nominal life = 20.000 h (Lh10)

3.0 kN 2.6

75 01 /m in

132

FR = permissible radial force in kN X = Distance between point of application of force and shaft shoulder (e.g. half pulley width)

Size FR in N when 2p=

2 56 63 71 80 90S/L 100L 112M 340 385 463 590 675 925 930 4 428 485 583 830 940 1295 1300 6 668 860 975 1335 1340 8

2.2

10 00 15 00

1.8

735 945 1070 1470 1476

FR

300 0

1.4

1.0 0 40 x 80 mm 120

Belt drive

The data apply only to the normal drive end shaft extension of IM B3 motors with one speed. Calculation of belt drive: FR = 19120 · P ·k D1 · n FR P n D1 k = = = = = Radial shaft load in N Output in kW Speed in min-1 Pulley diameter in m Belt tension factor, varying with the type of belt, assumed to be approximately: 3-4 for normal flat belt without idler pulley 2-2.5 for normal flat belt with idler pulley 2.2-2.5 for V-belt For exact data apply to the belt manufacturer.

14

Cooling

Surface cooling, independent of the direction of rotation. Motors type T available without internal fan, e.g. for installation in a directed air stream (outputs on request).

Vibration

The amplitude of vibration in electric motors is governed by EN 60034-14 Mechanical vibration of rotating electrical machines with shaft heights 56 and larger - methods of measurement and limits. Standard motors are designed to vibration class N (normal). Vibration class R (reduced) and vibration class S (special) are available at extra cost. Pole-changing motors in Dahlander connection can only be supplied in vibration class N. Rotors are at present dynamically balanced with half key fitted as per DIN ISO 8821. Other balancing only on request. The motors are identified as follows: "H" or "blank" means balanced with half key "F" means balanced with full key "N" means no key

Position and dimensions of key

b

l2 l3

t

h

d

l1

Frame size 56 63 71 80 90 100 112 132

d x l1 9 x 20 11 x 23 14 x 30 19 x 40 24 x 50 28 x 60 28 x 60 38 x 80

bxh 3x3 4x4 5x5 6x6 8x7 8x7 8x7 10 x 8

l2 15 15 20 30 40 50 50 70

l3 2.5 4 5 6 6 6 6 5

t 10.2 12.5 16 21.5 27 31 31 41

Dimensions in mm For larger shafts in special design the dimensions l2 and l3 are maintained.

15

Noise

The noise level of an electrical machine is determined by measuring the sound pressure level in accordance with curve A of the sound level meter to EN 60651 and is indicated in dB (A). The permitted noise levels of electrical machines are fixed in EN 60034-9 (IEC 34-9). The noise level of our motors is well below these limit values. Air-borne sound measurements are carried out in an anechoic testing chamber to EN 21680. Speed corresponding to a mains frequency of 50 Hz and the number of poles.

Measures for noise reduction

With special measures noise level can be reduced (special fan, noise reducing hood, etc.).

Noise levels

The noise values listed below refer to 50 Hz at rated voltage with a tolerance of up to + 3 dB(A). Values for pole-changing motors on request. For 60 Hz supply values are 3-5 dB(A) higher.

Sound pressure level LpA and sound power level LWA for three-phase squirrelcage motors Frame size 56 63 71 80 90 100 112 132 2 pole LWA LpA 57 58 61 70 72 76 79 77 48 49 52 61 63 67 70 67 4 pole LWA LpA 47 47 51 54 60 63 65 68 38 38 42 45 51 54 56 58 6 pole LWA LpA 8 pole LWA LpA

49 49 55 60 65 67

40 40 46 51 56 57

44 51 54 54 68

35 42 46 46 58

16

Brake motors

The induction brake is very often the part of the motor that has to bear most of the electrical and mechanical load, since it is affected by the transient dynamics of the brake's mechanical starts and stops. Therefore it is easy to understand why our brake motors are subject to the strictest quality control. Overall dimensions of our brake motors do not differ from series to series. This allows assembly of an AC or DC supplied brake, with the same performance standards. Depending on the type of end use, our brake motors are divided into two main groups:

Series FA-FC-FBA-FBC

These series are especially recommended for high braking torque requirements and other heavy-duty applications such as lifting, traversing and transmission in general. In their standard version the FA and FBA motors are available with three-phase AC coils, while the FC-FBC-FMC-FME motors are equipped with DC coils. DC brake supply is an ideal choice for applications where a very silent braking is required. This option, combined with the other main specifications of our different brake motors, allows for a large range of application possibilities.

Series FS

These are brake motors with reduced braking torque, especially indicated for machines that require controlled, but not necessarily precision braking (CE Directive Machines 89/392 CEE and Low voltage 93/68). They are suitable for small to medium capacity crane traversing and, using a special brake, in low moment inertia automation.

Protection

The standard mechanical protection of all brake motor series is IP 54. On request, higher degrees of protection can be supplied.

17

SERIES

Supply, speed and poles Three-phase single-speed 2, 4, 6, 8, poles Three-phase pole-changing 2/4, 4/8, 4/6, 6/8, 2/8 poles Three-phase single-speed 2, 4, 6, 8 poles Three-phase pole-changing 2/4, 4/8, 4/6, 6/8, 2/8 poles Single-phase single-speed 4 poles Single-phase single-speed 4 poles Three-phase single-speed 2,4 poles

Frame size

Rated output range 0.12-7.5

Braking range

Brake coils

Supply motor-brake 3~/3~

FA

63-132

7.5-100

AC

FBA

63-132

0.037-7.5

7.5-100

AC

3~/3~

FC

63-132

0.12-7.5

7.5-100

DC

3~/1~

FBC

63-132

0.037-7.5

7.5-100

DC

3~/1~

FMC

63-100

0.12-2.20

7.5-45

DC

1~/1~

FME

63-100

0.12-2.20

7.5-45

DC

1~/1~

FS

63-132

0.12-7.5

2.5-25

DC

3~/1~

Single-phase motors

Series M and ME

Series M are standard single-phase motors and series ME single-phase motors with high starting torque. The series ME with high starting torque is electrically and mechanically equivalent to series M, but additionally to the starting and running capacitor, these motors are equipped with an electronic timer. For easy handling and mounting of the motor, these three elements are located all together in one single component.

18

S.p.a . .e . p a.r.t s. .f.o.r. .t h r e.e.-.p . . a.s e. .m . . t . . r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .r . ... .. . ..... . .h . .. .. o . o. s

Series T and BP

9 10

47 46 44 43 32 31 29 28 27 24 22 21

11 21 7 16 17

6

5

4

3

52

51

50 2 48 46 49 1

Part description

1 2 3 4 5 6 7 9 10 11 16 17 21 22 23 Shaft protection Drive end dust seal Drive end endshield fixing screw Drive end endshield Stator Stator frame Terminal box gasket Terminal box fixing screw Terminal box Cable gland Terminal board fixing screw Terminal board Drive end bearing Motor shaft Hub key 24 27 28 29 31 32 43 44 46 47 48 49 50 51 52 Rotor assembly Non-drive end bearing Non-drive end pre-load washer Non-drive end shim ring Non-drive end endshield Non-drive end endshield fixing screw Fan Fan hose clamp Fan cowl Fan cowl fixing screw Feet Feet fixing bolt Flange B5 Seal ring Flange B14

In enquires and orders for spare parts please state always: Designation of spare part, motor type, mounting arrangement, motor serial number (Product No. when available) Enquires and orders cannot be handled without these data.

19

S.p.a . .e . p a.r.t s. .f.o.r. .b.r a.k . . .m. . . .o . .s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .r . ... .. . . .. .e .. ot . r .

Series FA, FC, FBA, FBC

44 12 41 39 38 47 46 43 42 40 37 35 34 32 31 30 27 26 24 22 21 20 19 52 51 50 6 5 4 3 23 18 25 36 14 15 16 17 13 8

7

2 48 48 49 1

Part description

1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Shaft protection Drive end dust seal Drive end endshield fixing screw Drive end endshield Stator Stator frame Terminal box gasket Terminal box lid fixing screw Terminal box lid Terminal box lid gasket Rectifier Brake terminal board Terminal board fixing screw Terminal board Terminal box bases Drive end shim ring Non-drive end pre-load washer Drive end bearing Motor shaft Hub key Rotor assembly Brake end hub key 26 27 30 31 32 34 35 36 37 38 39 40 41 42 43 44 46 47 48 49 50 51 52 Seeger ring endshield end Non-drive end bearing Seeger ring for motor shaft Non-drive end endshield Non-drive end endshield fixing screw Counter-disc Brake disc Hub Bushing Seeger ring shaft end Counter-brake coil Brake spring Brake coil Brake screw Fan Fan hose clamp Fan cowl Fan cowl fixing screw Feet Feet fixing bolt Flange B5 Seal ring Flange B14

In enquires and orders for spare parts please state always: Designation of spare part, motor type, mounting arrangement, motor serial number (Product No. when available) Enquires and orders cannot be handled without these data.

20

S.p.a . .e . p a.r.t s. .f.o.r. .b.r a.k . . .m. . . .o . .s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .r . ... .. . . .. .e .. ot . r .

Series FS

12 45 13 39 41 47 46 44 43 40 33 32 31 30 27 26 24 22 21 20 19 6 5 4 3 7 23 17 18 25 15 16 14 8

42

52 51 50

2 48 48 49 1

Part description

1 2 3 4 5 6 7 8 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Shaft protection Drive end dust seal Drive end endshield fixing screw Drive end endshield Stator Stator frame Terminal box gasket Terminal box lid fixing screw Terminal box lid Terminal box lid gasket Rectifier Brake terminal board Terminal board fixing screw Terminal board Terminal box bases Drive end shim ring Non-drive end pre-load washer Drive end bearing Motor shaft Hub key Rotor assembly Brake end hub key 26 27 30 31 32 33 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Seeger ring endshield end Non-drive end bearing Seeger ring for motor shaft Non-drive end endshield Non-drive end endshield fixing screw Thrust spring Counter-brake coil Brake spring Brake coil Brake screw Fan Fan hose clamp Locknut Fan cowl Fan cowl fixing screw Feet Feet fixing bolt Flange B5 Seal ring Flange B14

In enquires and orders for spare parts please state always: Designation of spare part, motor type, mounting arrangement, motor serial number (Product No. when available) Enquires and orders cannot be handled without these data.

21

E . .r . . e . i .n . .l.e.c.t . .i.c.a.l. .d . . s. .g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rated voltage

For the rated voltage of the motors, EN 60 034-1 allows a tolerance of ± 5 %. According to IEC 60038, the mains voltages may have a tolerance of ± 10 %. Therefore the motors are designed for the following rated voltage ranges (exceptions are shown in the data tables):

Mains voltage to DIN IEC 38 230 V ± 10% 400 V ± 10% 690 V ± 10%

Rated voltage range of motor 218-242 V ± 5% 380-420 V ± 5% 655-725 V ± 5%

Within the rated motor voltage range, the permissible maximum temperature is not exceeded. When the motors are operated at the limits of the voltage tolerance, the permissible overtemperature of the stator winding may be exceeded by 10 K. For frame sizes 56 to 132 nameplates are marked with the maximum rated currents within the stated voltage ranges.

Rated frequency

50 Hz motors can also be operated on 60 Hz mains, provided the mains voltage increases proportionally to the frequency. The relative values for starting and breakaway torque remain nearly unchanged and slightly increase for the starting current. The rated speed increases by the factor 1.2 and output by factor 1.15. Should a motor designed for 50 Hz be operated at 60 Hz without the voltage being increased, the rated output of the motor cannot be increased. Under these operating conditions, rated speed increases by factor 1.2. The relative values for starting and breakaway torque are reduced by factor 0.82 and for starting current by factor 0.9.

Rated current

The rated currents listed in the data tables apply to an operating voltage of 400 V. The conversion to other operating voltages, with output and frequency remaining unchanged, is to be made as follows: Nominal voltage (V) Conversion factor x lN 230 1.74 380 1.05 400 1.0 440 0.91 500 0.80 660 0.61 690 0.58

22

Rated torque

Rated torque in Nm = 9550 x Rated voltage in kW Rated speed in min-1

Output

The outputs stated in this catalogue are for constant load in continuous running duty S1 according to EN 60034-1, based on an ambient temperature of 40° C and installation at altitudes up to 1000 m above sea level. For severe operating conditions, e.g. high switching rate, long run-up time or electric braking, a thermal reserve is necessary, which could call for higher thermal class or the use of a motor with a higher rating. In these cases we recommend to enquire with detailed information on the operating conditions.

Overload

At operating temperature three-phase motors are capable of withstanding an overload for 15 seconds at 1.5 times the rated torque at rated voltage. This overload is according to EN 60034-1 and will not result in excessive heating. Utilizing thermal class F, motors can be operated continuously with an overload of 12 %. Nevertheless this is not valid for motors which to catalogue are utilized to thermal class F.

Brake motors

Except for brake motors for special applications, all motors are according to thermal class F. Supply voltage corresponds to Eurovoltage (230-400 V and 400/692 V, 50 Hz). On request, brake motors with special voltage, special duty and for special applications are available. The windings of the brake coil are adapted to the motor voltage. The three- and single-phase coils are designed for continuous duty with running motor. Motors with DC brake coil are equipped with the corresponding rectifier. The brake is connected in the terminal box of the motor.

23

Connection diagrams

Windings of standard three-phase motors can be connected either in star or delta connection.

U1 W2 U2 V2

Star connection A star connection is obtained by connecting W2, U2, V2 terminals to eachother and the U1, V1, W1 terminals to the mains. The phase current and voltage are: Iph = In ; Uph = Un /

3

U1 W1 V1

V1

W1

L1

L2

L3

where In is the line current and Vn the line voltage referred to the star connection.

V2

U1 W2 U2

Delta connection A delta connection is obtained by connecting the end of a phase to the beginning of the next phase. The phase current Iph and the phase voltage Uph are:

U1

V1

W1

W1

V1

L1

L2

L3

Iph = In /

3;

Uph = Un

where In and Un are referred to the delta connection. Star-delta starting Star-delta starting allows a peak current reduction, ensuring however that the peak torque obtained is bigger than the resistant torque. Actually, it should be noted that the torque of an induction squirrel-cage motor is directly proportional to the square of the voltage. Motors whose rated voltage with delta connection corresponds to the mains voltage, can be started with the star-delta method. All motors can be supplied with windings designed for star-delta starting (for example: 400 V / 690 V Y). Pole-changing motors Standard pole-changing motors are designed for single voltage and direct-on-line starting (special design for Y--connection on request). When the ratio between the two speeds is from 1 to 2, the standard motors have one single winding (Dahlander connection). For the other speeds, the motors have two separate windings.

BP - two separate windings Y / Y

L1 L2 L3 L1 L2

BP ­ Dahlander connection YY /

L3

2U 2U 2V 2W

1U 2U 2V 2W 2U 2U 2V 2W 2V 1U 1V 1W 1W 1V 2W 1U 1V 1W 1W 1U 1W 2V 1V 1U 1V 1W

1U 2U 2W 1U 2U 1V 1V 1W 2V 2W

2W

2V

High speed

Low speed

L1 L2 L3

High speed

Low speed

L1 L2 L3

24

Brake motors

SERIES FA MOTOR

U1 W2 U2 V2

U2 V1 L2

BRAKE

W1 V2

MOTOR

U1

L3

BRAKE

U1 W2 U2 V2

U2 V1 L2 W2 W1 V2 L3

U1

W2

U1

U1 W1 V1

V1

W1 W1 V1

U1

L1

V1

W1 W1 V1

U1

W1

V1

L1

L2

L3

L1

L2

L3

SERIES FBA DAHLANDER MOTOR

W2

L1 L2 L3 U1

V2

BRAKE

W1

MOTOR

U1 U1

L3

BRAKE

W1 V2

2W

2U

2V

U2 V1

2W V2 W2 1U

2U

2V

U2 V1

L2

W2

L1

V2

U2

W1

U2

V1 L1 L2 L3

High speed

Low speed

SERIES FBC DUAL-WOUND MOTOR

L1 L2 L3 W2 W2 U2 V2

U2 V1

BRAKE

W1

MOTOR

U1 W2

L3

BRAKE

W1 V2

U1

V2

U2

V2

U1

U2

L2

V1

U1 V2 U2

V1

W1

W2 U1

U1 W1 V1

V1

W1

W2 U1

W1

V1

L1

W1 L1 L2 L3

V1

High speed

Low speed

SERIES FC

RECTIFIER

U1 RECTIFIER BRAKE W2 U2 V2 RED W2 U2 V2 RED U1

RECTIFIER

BRAKE

W1

V1 BLACK

U1 W1 V1

V1

W1

BLACK

RECTIFIER

U1

V1

W1

L1

L2

L3

BRAKE

L1

L2

L3

SERIES FBC DAHLANDER

L N L N

W2

L1

L2

L3

RECTIFIER

2W 2U 2V BLACK RED V2

U1 2W W2 1U 1V 1W 2U 2V BLACK

RECTIFIER

RED

1U

1V

1W

V2

U2

BRAKE

W1

U2

V1 L1 L2 L3

BRAKE

High speed

Low speed

SERIES FBC DUAL-WOUND

L L1 L2 L3 N L N

W2 W2 U2 V2 BLACK

RECTIFIER

RED

U1 W2 U2 V2 BLACK

RECTIFIER

RED

U1 V2 U2

V1

W1

U1

V1

W1

BRAKE

W1

V1

BRAKE

L1 L2 L3

High speed

Low speed

BRAKE

25

L1

L2

L3

L1

W1

V1

U1

1U

1V

1W

1V

1W W1 V1

W2

U1

L2

L3

L1

Single-phase motors

Single-phase motors are designed for a single rated voltage. The windings (running and starting winding) are connected to the capacitor supplied with the motor. The direction of rotation can be reversed by inverting the winding ends.

SERIES M

SERIES ME

LI

RUNNING CAPACITOR SExx

LA

RUNNING CAPACITOR

RUNNING

STARTING CAPACITOR

STARTING

N

SExx - Electronic device for connection of starting capacitor

RUNNING

STARTING CAPACITOR

N

Insulation and temperature rise

Class F insulation to EN 60034-1 is used throughout. In standard design motors are intended for operation at 40° C ambient temperature with class B temperature rise only, with an overtemperature limit of 80 K. This also applies for the rated voltage range to IEC 60038. Exceptions are shown on the data tables.

Temperature rise (T*) and maximum temperatures at the hottest points of the winding (Tmax) according to the temperature classes of EN 60034-1. T* Class B Class F Class H

*Measurement by resistance method

Tmax 125° C 155° C 180° C

80 K 105 K 125 K

Output reduction at ambient temperatures over 40° C

45° C Ambient temperature Reduction of nominal output to approx. 95 % 50° C 90 % 55° C 85 % 60° C 80 %

When a winding is utilized to temperature class F (105K), no output reduction is required up to an ambient temperature of 60° C. This does not apply to motors which in their standard design are already utilized to thermal class F.

26

Installation at altitudes of more than 1000 m above sea level (see also EN 60034-1)

Altitude of installation At 40°C ambient temperature and thermal class B Rated output reduced to approx. At 40°C ambient temperature and thermal class F Rated output reduced to approx. Full nominal output to data tables with thermal class B and ambient temperature of Full nominal output to data tables with thermal class F and ambient temperature of 2000 m 92 % 89 % 32° C 30° C 3000 m 84 % 79 % 24° C 19° C 4000 m 76 % 68 % 16° C 9° C

Starting rate

The permissible number of starts per hour can be taken as given in the table below, provided the following conditions are met: Additional moment of inertia moment of inertia of the rotor: load torque rising with the square of the speed up to nominal torque; starts at even intervals.

Shaft height

Permissible No. of starts per hour for 2p =2 =4 250 140 60 6 350 160 80

56 - 71 80 - 100 112 - 132

100 60 30

27

Thermal protection

The decision on a particular type of thermal protection should be taken according to the actual operating conditions. Motors may be protected by means of current-dependent thermal protection switches, overcurrent relays and temperature detectors.

Thermal protection is possible as follows: · Thermal protection switch with bimetal release · Thermistor protection with semiconductor temperature detectors (PTC) in the stator winding in connection with release (if required, with additional motor protection switch). · Bimetal temperature detector as N/C or N/O in the stator winding (if required, with additional motor protection switch). · Resistance thermometer for monitoring winding and bearing temperature.

Should protection of the motor be required, we install protection switch with bimetal release up to frame size 112 and semiconductor temperature detectors in motors 132.

Although there are motors available from stock with built-in semiconductor temperature detector, a special remark has to be made in the enquiry or order when motor protection is required.

Operating specifications Thermal cut-out

NORMALLY OPEN

N/O TYPE Ti = Activation temperature Tr = Reset temperature

1

0

Tr

Ti

K

Operating specifications of the thermistors

NORMALLY CLOSED

N/C TYPE Ti = Activation temperature Tr = Reset temperature

PTC TYPE Ti = Activation temperature

OHM

1

Resistance 0

0

Tr

Ti

K

Ti

K

28

Examples of connection

Protection method

Protection

Motor protection switch with thermal and electromagnetic overcurrent release

against: · Overload in continuous service · Locked rotor

Contactor with overcurrent relay Thermistor protection and fuse

in service against: · Overload in continous service · Long starting and braking periods · High switching rate in case of fault against: · Obstruction of cooling · Increased ambient temperature · Single-phase operation · Frequency fluctuations · Switching against locked rotor

Semiconductor temperature detector with release

in service against: · Overload in continous service · Long starting and braking periods · High switching rate in case of fault against: · Obstruction of cooling · Increased ambient temperature · Single-phase operation · Frequency fluctuations · Switching against locked rotor

29

Or . e . d . . . . . .d . .r . . . a.t.a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Motors for normal continuous duty (S1) and normal operating conditions

Quotation (if submitted) Quantity Designation Output (for pole-changing motors, outputs referred to speeds) Speed (for pole-changing motors, outputs referred to outputs) Direction of rotation (viewed on shaft extension) Mounting arrangement (to IEC 60034-7) Degree of protection, motor/terminal box (to IEC 60034-5) Mains voltage Mains frequency Method of starting (direct-on-line or Y-) Location of terminal box Machine to be driven V Hz No./Date Units Type

kW

min-1

Dimensions of cables, if these differ from those allocated by VDE 0100, referred to an ambient temperature of 40° C, or when aluminium conductors are used. It should be stated when parallel connected conductors are used.

30

Additional information for special duties and difficult operating conditions

S 2: ... min (short-time duty) S 3: ... % - ... min (intermittent duty) S 4: ... % - JM ... kgm2 - Jext ... kgm2 (intermittent duty with starting) S 5: ... % - JM ... kgm2 - Jext ... kgm2 (intermittent duty with electric braking) S 6: ... % - min (continuous-operation periodic duty with intermittent load) S 7: .JM ... kgm2 - Jext ... kgm2 (continuous-operation periodic duty with electric braking) S 8: .JM ... kgm2 - Jext ... kgm2 (continuous-operation periodic duty with speed changes) S 9: ... kW equ (continuous duty with non-periodic load and speed variations). For this duty type suitable full load values should be taken as the overload concept. S10: p/t .... r .... TL (Duty with discrete constant loads). Starting conditions (no-load or loaded starting) Shock loads Load torque curve during run-up (characteristic) Moment of inertia (Jext) referred to the motor shaft Description of the type of drive (direct coupling, flat or V-belt, straight or helical gears, sprocket, crank, eccentric cam, etc.) Radial force (or diameter of drive element) N kgm2

Direction of force and point of application (distance from shaft shoulder or width of drive element) mm Axial force and direction of application (pull/thrust) N

Ambient conditions (e.g. increased humidity, dust accumulation, corrosive gases or vapours, increased or extremely low ambient temperature, outdoor installation, installation at altitudes over 1000 m above sea level, extraneous vibration, etc.)

31

Three-phase squirrel cage motors 230-400 V - 50 Hz Protection IP 55

Series T

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

3000 min-1 (2 poles)

56 B2 63 A2 63 B2 71 A2 71 B2 80 A2 80 B2 90S A2 90L B2 100L A2 112M A2 132S A2 132M B2 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 2720 2740 2770 2820 2820 2830 2840 2850 2860 2850 2910 2910 2930 0.40 0.60 0.70 1.15 1.60 1.90 2.60 3.40 5.00 6.20 8.20 12.00 14.80 56 56 66 68 71 76 77 79 80 81 85 83 86 0.77 0.78 0.78 0.69 0.70 0.75 0.79 0.81 0.79 0.86 0.83 0.80 0.85 0.42 0.63 0.86 1.25 1.86 2.53 3.70 5.03 7.34 10.00 13.13 18.04 24.40 2.7 2.7 3.2 3.6 3.6 3.6 3.7 2.7 3.9 2.8 2.9 2.9 3.2 3 3 3 3.7 3.5 3.6 3.8 3.1 4 3.1 3 3.3 3.4 3 3.5 4.5 4.6 4.7 5.7 6.5 5.8 6.9 6.2 7.8 6.5 7 0.09 0.13 0.19 0.36 0.46 0.77 0.91 1.15 1.80 3.25 6.20 13.10 17.50 3.5 4.1 4.6 5.7 6.3 9.0 10.5 13.0 15.0 19.6 36.0 45.0 50.0

32

Three-phase squirrel cage motors 230-400 V - 50 Hz Protection IP 55

Series T

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500 min-1 (4 poles)

56 B4 63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 90L C4 100L A4 100L B4 112M A4 132S A4 132M B4 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 3.00 4.00 5.50 7.50 1360 1350 1350 1370 1380 1380 1390 1410 1410 1410 1410 1410 1430 1450 1450 0.41 0.46 0.70 0.69 1.18 1.38 2.00 2.60 3.60 4.50 5.10 7.10 9.00 11.90 16.00 53 54 53 67 68 72 72 79 79 79 80 80 84 87 87 0.60 0.69 0.70 0.77 0.67 0.80 0.75 0.77 0.76 0.73 0.78 0.80 0.76 0.77 0.78 0.63 0.85 1.27 1.74 2.56 3.80 5.15 7.45 10.16 12.20 14.90 18.04 26.40 36.20 49.40 2.6 2 2 2 2.2 1.9 2.6 2.3 2.4 3.1 2.4 2.9 3.1 2.3 2.8 2.7 2 2 2.1 2.3 2.2 2.2 2.6 2.6 3.1 2.6 3.3 3.6 2.6 3 2.4 2.4 2.3 3.4 4 3.9 3.9 4.6 4.8 5.2 4.8 6.5 6.6 5.4 6.3 0.14 0.25 0.31 0.54 0.76 1.47 1.90 2.75 3.20 3.72 4.93 5.97 10.56 19.40 28.60 3.4 4.1 4.6 5.1 6.3 9.0 9.9 11.8 14.3 15.5 18.7 21.0 36.0 45.0 55.0

33

Three-phase squirrel cage motors 230-400 V - 50 Hz Protection IP 55

Series T

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1000 min-1 (6 poles)

56 B6 63 A6 63 B6 71 A6 71 B6 80 A6 80 B6 90S A6 90L B6 100L A6 100L B6 112M A6 132S A6 132M B6 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 3.00 5.50 780 890 870 850 870 880 900 910 900 935 935 945 960 950 0.33 0.67 0.70 0.70 1.00 1.35 1.74 2.20 3.30 4.10 4.90 6.30 7.70 12.97 40 40 45 51 53 56 65 68 69 75 76 79 84 85 0.65 0.49 0.55 0.73 0.68 0.71 0.70 0.72 0.70 0.70 0.70 0.64 0.67 0.72 0.73 0.96 1.32 2.00 2.74 4.00 5.83 7.87 11.67 15.30 18.40 22.23 29.84 55.30 1.3 2.5 1.3 1.4 2.2 2.2 2 2.2 1.9 2.1 2.3 2.7 2.5 2.1 1.8 2.5 2 2.1 2.1 2.1 2.1 2.1 2 2.5 2.5 2.7 2.4 3.1 1.3 1.7 1.8 2.1 2.7 2.7 3 3.7 3.1 4.2 4.4 4.6 5.4 5.8 0.23 0.30 0.40 0.60 0.90 1.32 1.78 2.80 3.50 6.40 7.90 11.00 20.00 35.00 3.5 4.1 4.6 5.7 6.3 8.8 10.5 13.0 16.5 21.0 30.2 40.0 45.0 60.0

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway torque Mn (Nm)

Breakaway torque ratio MA/MN

Pull-up torque ratio MM/MN

Starting current ratio IA/IN

Moment of inertia

Weight

kW

min-1

100%

cos

10-3 kgm2

kg

750 min-1 (8 poles)

63 B8 71 B8 80 A8 80 B8 90S A8 90L B8 100L A8 100L B8 112M B8 132S A8 132M B8 0.08 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 630 670 670 680 670 670 690 690 710 710 705 0.48 0.69 0.92 1.28 1.40 2.20 2.50 3.90 4.50 6.80 7.70 45 49 47 50 61 62 67 68 76 73 80 0.53 0.51 0.60 0.56 0.62 0.58 0.65 0.60 0.63 0.64 0.70 1.21 1.71 2.56 3.50 5.30 7.84 10.40 15.20 20.20 29.60 40.60 1.3 2.5 1.8 1.9 1.7 1.6 1.7 1.8 1.7 1.6 1.5 1.8 2.9 2 2.1 2.2 2.1 1.9 2 2.4 2 2.2 1.3 2.4 2.1 2.3 2.5 2.5 2.9 2.9 3.9 4.5 5.2 0.40 0.90 1.32 1.78 2.80 3.50 6.40 7.90 11.00 20.00 35.00 4.6 6.3 9.0 9.5 13.0 15.3 20.0 22.3 36.0 45.0 55.0

34

Pole-changing three-phase motors 400 V - 50 Hz Protection IP 54

Series BP

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

3000/1500 min-1 (2/4 poles) - Dahlander connection

63 A2/4 63 B2/4 71 A2/4 71 B2/4 80 A2/4 80 B2/4 90S A2/4 90L B2/4 100L A2/4 100L B2/4 112M A2/4 132S A2/4 132M B2/4 0.16 0.11 0.22 0.15 0.30 0.20 0.45 0.30 0.60 0.45 0.80 0.60 1.40 1.00 1.80 1.25 2.50 1.80 3.30 2.60 4.40 3.30 5.50 4.50 7.50 6.00 2700 1270 2710 1280 2750 1330 2780 1350 2800 1380 2820 1390 2830 1400 2830 1390 2860 1410 2880 1400 2900 1410 2910 1400 2920 1405 0.56 0.46 0.70 0.58 0.90 0.72 1.30 1.06 1.78 1.49 2.22 1.74 3.66 2.86 4.57 3.38 5.95 4.74 7.74 6.86 10.08 8.14 12.57 11.14 16.32 14.83 57 58 60 63 64 65 68 71 73 75 75 77 78 53 55 57 59 67 70 70 73 74 77 79 81 80 0.72 0.65 0.78 0.68 0.80 0.70 0.79 0.69 0.76 0.65 0.80 0.71 0.81 0.72 0.80 0.73 0.83 0.74 0.82 0.71 0.84 0.74 0.82 0.72 0.85 0.73 0.55 0.83 0.77 1.12 1.04 1.43 1.54 2.12 2.05 3.11 2.71 4.12 4.73 6.82 6.07 8.58 8.35 12.19 10.94 17.73 14.48 22.35 18.05 30.69 24.53 40.78 1.3 1.6 2.2 2.5 2.2 2.0 2.1 2.4 2.3 2.5 2.5 2.6 2.4 2.3 2.3 2.2 2.4 2.2 2.1 2.3 2.2 2.3 2.4 2.5 2.2 2.5 1.7 1.4 2.5 3.0 2.4 2.9 2.3 2.7 2.2 2.4 2.6 2.8 2.7 2.9 2.7 2.8 2.6 2.5 2.7 2.6 2.8 2.5 2.6 2.4 2.8 2.6 2.4 2.6 3.3 3.5 3.1 3.3 3.4 3.3 3.2 3.4 3.4 3.6 3.5 3.6 3.5 3.4 4.3 4.2 4.5 4.4 5.6 5.5 6.3 6.5 6.5 7.0 0.25 0.31 0.54 0.76 1.47 1.90 2.75 3.72 4.93 5.97 10.56 19.40 28.60 4.1 4.6 5.1 6.3 9.0 9.9 11.8 15.5 18.7 21.0 36.0 45.0 55.0

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway torque Mn (Nm)

Breakaway torque ratio MA/MN

Pull-up torque ratio MM/MN

Starting current ratio IA/IN

Moment of inertia

Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500/750 min-1 (4/8 poles) - Dahlander connection

63 A4/8 71 B4/8 80 A4/8 80 B4/8 90S A4/8 90L B4/8 100L A4/8 100L B4/8 112M A4/8 112M A4/8 132S A4/8 132M B4/8 0.09 0.04 0.15 0.09 0.37 0.20 0.55 0.30 0.75 0.37 0.90 0.50 1.40 0.70 1.60 0.90 1.70 1.00 2.20 1.30 3.70 2.20 4.70 2.80 1280 620 1305 610 1320 630 1350 650 1380 670 1400 680 1405 685 1410 690 1420 700 1410 690 1430 690 1445 710 0.32 0.24 0.52 0.53 1.20 1.09 1.69 1.50 2.10 1.53 2.39 1.89 3.50 2.59 3.80 2.98 4.03 3.26 5.29 4.25 8.89 7.08 10.34 8.77 54 56 59 60 65 68 73 75 77 78 77 80 40 40 42 45 53 56 60 64 67 69 66 72 0.76 0.60 0.75 0.61 0.76 0.63 0.78 0.64 0.79 0.66 0.80 0.68 0.79 0.65 0.81 0.68 0.79 0.66 0.77 0.64 0.78 0.68 0.82 0.64 0.67 0.62 1.09 1.40 2.67 3.03 3.89 4.41 5.19 5.27 6.14 7.02 9.52 9.76 10.84 12.46 11.43 13.64 14.90 18.00 24.70 30.45 31.06 37.66 1.3 1.6 2.2 2.5 2.2 2.0 2.1 2.4 2.3 2.5 2.5 2.6 2.4 2.3 2.3 2.2 2.4 2.2 2.1 2.3 2.2 2.3 2.4 2.5 1.7 1.4 2.5 3.0 2.4 2.9 2.3 2.7 2.2 2.4 2.6 2.8 2.7 2.9 2.7 2.8 2.6 2.5 2.7 2.6 2.8 2.5 2.6 2.4 2.1 2.0 2.4 2.6 2.6 2.7 2.7 2.5 3.0 3.2 3.0 3.3 3.5 3.6 3.5 3.4 3.9 3.6 4.6 4.0 5.0 4.2 5.2 4.4 0.31 0.54 1.47 1.90 2.75 3.72 6.40 7.90 11.00 13.54 20.10 35.00 4.6 5.1 9.0 9.9 11.8 15.5 18.7 21.0 36.0 39.0 45.0 55.0

35

Pole-changing three-phase motors 230/400 V - 50 Hz Protection IP 54

Series BP

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500/1000 min-1 (4/6 poles) - Separate windings

63 A4/6 71 B4/6 80 A4/6 80 B4/6 90S A4/6 90L B4/6 100L A4/6 112M A4/6 112M B4/6 132S A4/6 132M B4/6 0.18 0.04 0.22 0.15 0.37 0.26 0.55 0.45 0.75 0.50 1.10 0.75 1.50 0.90 1.80 1.30 2.60 1.80 4.00 2.60 5.50 3.70 1320 840 1360 860 1380 870 1380 880 1400 905 1410 910 1405 900 1420 910 1430 915 1425 920 1435 930 0.68 0.17 0.69 0.61 1.05 0.98 1.50 1.56 1.90 1.70 2.65 2.44 3.56 2.73 4.00 3.73 5.86 5.09 9.02 7.36 11.95 10.49 54 63 67 69 73 75 77 80 81 80 82 52 55 60 63 65 67 71 74 74 75 76 0.70 0.64 0.73 0.65 0.76 0.64 0.77 0.66 0.78 0.65 0.80 0.66 0.79 0.67 0.81 0.68 0.79 0.69 0.80 0.68 0.81 0.67 1.30 0.45 1.54 1.66 2.56 2.85 3.80 4.88 5.12 5.27 7.45 7.87 10.19 9.54 12.10 13.64 17.36 18.78 26.80 26.98 36.60 37.99 2.4 1.5 2.3 1.6 2.4 1.7 2.5 1.7 2.6 1.7 2.5 1.6 2.7 1.7 2.9 1.8 3.0 2.0 3.2 2.2 3.1 2.1 2.3 1.6 2.2 1.5 2.5 1.7 2.6 1.8 2.7 2.0 2.8 2.2 2.6 2.3 2.8 2.5 3.0 2.6 3.1 2.7 3.2 2.8 2.1 1.8 2.3 1.9 2.4 2.0 3.2 2.8 3.4 3.0 3.7 3.2 4.1 3.8 4.4 4.0 5.5 4.4 5.7 4.8 5.6 4.4 0.31 0.76 1.47 1.90 2.75 3.72 7.90 11.00 13.54 20.00 35.00 4.6 5.1 9.0 9.9 11.8 15.5 18.7 36.0 39.0 45.0 55.0

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway torque Mn (Nm)

Breakaway torque ratio MA/MN

Pull-up torque ratio MM/MN

Starting current ratio IA/IN

Moment of inertia

Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500/750 min-1 (4/8 poles) - Separate windings

63 A6/8 71 B6/8 80 A6/8 90S A6/8 90L B6/8 100L B6/8 112M B6/8 132S A6/8 132M B6/8 0.07 0.037 0.18 0.09 0.25 0.18 0.37 0.25 0.55 0.37 0.75 0.55 1.10 0.75 1.50 1.10 2.20 1.50 840 600 845 620 860 640 870 660 890 680 900 670 905 690 910 700 920 700 0.30 0.21 0.74 0.48 0.94 0.89 1.26 1.15 1.77 1.65 2.25 2.21 3.07 2.88 3.92 3.72 5.51 4.71 52 54 58 63 67 73 76 79 80 46 48 53 56 59 63 67 70 73 0.64 0.55 0.65 0.56 0.66 0.55 0.67 0.56 0.67 0.55 0.66 0.57 0.68 0.56 0.70 0.61 0.72 0.63 0.79 0.59 2.03 1.38 2.77 2.68 4.06 3.62 5.90 5.20 7.96 7.84 11.60 10.38 15.74 15.00 22.84 20.46 2.0 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.8 2.6 1.9 2.4 2.0 2.6 2.3 2.4 2.1 1.4 1.3 1.6 1.5 1.7 1.8 2.2 .2.1 2.1 1.8 2.3 1.9 2.7 2.5 3.2 2.8 3.5 3.1 3.8 3.3 4.6 4.2 5.5 4.4 5.5 4.6 0.31 0.76 1.90 2.75 3.72 7.90 11.00 20.00 35.00 4.6 5.1 9.0 11.8 15.5 18.7 36.0 45.0 55.0

2.3 2.1 2.5 2.2 2.3 2.5 3.0 2.8 3.1 2.7

36

Pole-changing three-phase motors 230/400 V - 50 Hz Protection IP 54

Series BP

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

3000/750 min-1 (2/8 poles) - Separate windings

63 A2/8 71 B2/8 80 A2/8 90S A2/8 90L B2/8 100L A2/8 100L B2/8 112M A2/8 132S A2/8 132M B2/8 0.18 0.06 0.30 0.09 0.55 0.12 0.75 0.18 1.10 0.30 1.50 0.37 1.80 0.45 2.20 0.55 3.00 0.75 4.00 1.10 2760 600 2770 620 2800 640 2810 675 2810 680 2815 690 2810 680 2820 700 2825 710 2830 715 0.59 0.36 0.92 0.48 1.53 0.59 1.89 0.76 2.62 1.26 3.30 1.33 3.91 1.59 4.66 1.77 6.06 2.31 8.18 3.25 56 59 64 69 74 78 80 83 84 84 40 43 47 54 56 63 65 70 71 73 0.78 0.60 0.80 0.63 0.81 0.62 0.83 0.63 0.82 0.61 0.84 0.64 0.83 0.63 0.82 0.64 0.85 0.66 0.84 0.67 0.62 0.95 1.03 1.39 1.87 1.79 2.55 2.54 3.74 4.21 5.08 5.12 6.12 6.32 7.45 7.50 10.14 10.09 13.50 14.69 2.4 1.5 2.3 1.6 2.4 1.7 2.5 1.7 2.6 1.7 2.5 1.6 2.7 1.7 2.9 1.8 3.0 2.0 3.2 2.2 2.3 1.6 2.2 1.5 2.5 1.7 2.6 1.8 2.7 2.0 2.8 2.2 2.6 2.3 2.8 2.5 3.0 2.6 3.1 2.7 2.1 1.8 2.3 1.9 2.4 2.0 3.2 2.8 3.4 3.0 3.7 3.2 4.1 3.8 4.4 4.0 5.5 4.4 5.7 4.8 0.31 0.76 1.90 2.75 3.72 4.93 5.97 10.56 19.40 28.60 4.6 5.1 9.0 11.8 15.5 18.7 21.0 36.0 45.0 55.0

37

Single-phase motors with running capacitor 230 V - 50 Hz Protection IP 54

Series M

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Running capacitor C (µF) Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

3000 min-1 (2 poles)

56 B2 63 A2 63 B2 71 A2 71 B2 80 A2 80 B2 90S A2 90L B2 100L B2 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.85 2.20 2600 2710 2730 2720 2740 2790 2800 2860 2880 2910 1.23 1.47 1.85 2.56 3.75 5.10 7.35 9.60 11.78 13.43 47 55.5 64.6 64.4 65.8 70.6 72.6 74 75 77.2 0.90 0.97 0.91 0.98 0.97 0.90 0.89 0.92 0.91 0.93 1.14 0.63 0.88 1.40 1.92 2.56 3.78 5.13 6.13 7.32 1.3 1.2 1.0 0.8 0.7 0.7 0.8 0.9 0.8 0.6 1.8 1.4 1.3 1.6 1.7 2.0 2.0 2.1 2.4 2.1 1.3 2.7 3.0 2.9 2.7 3.3 3.5 3.5 3.8 5.9 6.3 8.0 10.0 16.0 20.0 20.0 30.0 45.0 50.0 60.0 0.09 0.13 0.19 0.36 0.46 0.77 0.91 1.15 1.80 3.25 3.0 4.1 4.6 5.7 7.0 9.0 9.9 13.0 15.3 21.0

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway torque Mn (Nm)

Breakaway torque ratio MA/MN

Pull-up torque ratio MM/MN

Starting current ratio IA/IN

Running capacitor C (µF)

Moment of inertia

Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500 min-1 (4 poles)

56 B4 63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 100L A4 100L B4 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 1100 1370 1290 1340 1370 1370 1390 1353 1380 1380 1410 0.95 1.32 2.00 2.26 3.00 3.70 5.40 7.23 10.10 11.74 15.16 45 46 47.4 53.4 60.4 65.9 67.4 67.2 68 71.2 72.6 0.91 0.85 0.85 0.90 0.87 0.97 0.89 0.95 0.95 0.95 0.88 0.76 0.84 1.33 1.78 2.57 3.82 5.14 7.59 10.44 12.60 15.24 0.7 1.3 0.8 0.7 0.8 0.8 0.7 0.7 0.9 0.7 0.6 1.2 1.4 1.2 1.5 1.6 1.4 1.7 1.6 1.7 1.8 2.1 1.5 2.0 1.8 2.2 2.7 3.1 3.2 3.0 2.7 3.2 3.2 8.0 8.0 8.0 16.0 16.0 20.0 25.0 35.0 40.0 50.0 60.0 0.14 0.25 0.31 0.54 0.76 1.47 1.90 2.75 3.20 4.93 5.97 3.5 4.1 4.1 5.5 6.3 9.0 10.3 13.0 15.5 23.0 24.0

38

Single-phase motors with running capacitor 230 V - 50 Hz Protection IP 54

Series M

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Running capacitor C (µF) Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1000 min-1 (6 poles)

71 B6 80 A6 80 B6 90S A6 90L B6 100L A6 100L B6 0.18 0.30 0.37 0.55 0.75 1.10 1.50 840 850 870 890 890 900 910 1.87 2.49 3.23 3.87 5.12 7.09 10.15 48 54 56 65 67 71 73 0.87 0.97 0.89 0.95 0.95 0.95 0.88 2.04 3.37 4.06 5.90 8.05 11.67 15.74 0.8 0.8 0.7 0.7 0.9 0.7 0.6 1.6 1.4 1.7 1.6 1.7 1.8 2.1 2.7 3.1 3.2 3.0 2.7 3.2 3.2 16.0 20.0 25.0 35.0 60.0 60.0 60.0 0.90 1.32 1.78 2.80 3.50 6.40 7.90 6.3 8.8 10.5 13.0 16.5 21.0 30.2

39

Single-phase motors with high starting torque with starting and running capacitor 230 V - 50 Hz Protection IP 54

Series ME

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Starting current ratio IA/IN Running capacitor C (µF) Starting capacitor Moment of inertia Weight

kW

min-1

100%

cos

C (µF-0+20%) 10-3 kgm2

kg

3000 min-1 (2 poles)

63 A2 63 B2 71 A2 71 B2 80 A2 80 B2 90S A2 90L B2 100L B2 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.85 2.20 2710 2730 2720 2740 2790 2800 2860 2880 2910 1.47 1.85 2.56 3.75 5.10 7.35 9.60 11.78 13.43 55.5 64.6 64.4 65.8 70.6 72.6 74 75 77.2 0.97 0.91 0.98 0.97 0.90 0.89 0.92 0.91 0.93 0.63 0.88 1.40 1.92 2.56 3.78 5.13 6.13 7.32 1.9 2.5 2.3 2.3 2.5 2.3 2.5 2.3 2.1 1.4 1.3 1.6 1.7 2.0 2.0 2.1 2.4 2.1 2.2 3.0 2.8 3.2 3.4 3.5 3.9 3.9 5.9 8.0 8.0 16.0 20.0 20.0 25.0 35.0 35.0 50.0 20.0 20.0 25.0 45.0 45.0 60.0 70.0 200.0 250.0 0.13 0.19 0.36 0.46 0.77 0.91 1.15 1.80 3.25 4.1 4.6 5.7 7.0 9.0 9.9 13.0 15.3 21.0

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN

Pull-up torque ratio MM/MN

Starting current ratio IA/IN

Running capacitor C (µF)

Starting capacitor

Moment of inertia

Weight

kW

min-1

100%

cos

C (µF-0+20%) 10-3 kgm2

kg

1500 min-1 (4 poles)

63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 100L A4 100L B4 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 1370 1290 1340 1370 1370 1390 1353 1380 1380 1410 1.32 2.00 2.26 3.00 3.70 5.40 7.23 10.10 11.74 15.16 46 47.4 53.4 60.4 65.9 67.4 67.2 68 71.2 72.6 0.85 0.85 0.90 0.87 0.97 0.89 0.95 0.95 0.95 0.88 0.84 1.33 1.78 2.57 3.82 5.14 7.59 10.44 12.60 15.24 3.0 2.6 2.3 2.5 2.5 2.5 2.5 2.2 2.2 2.5 1.4 1.2 1.5 1.6 1.4 1.7 1.6 1.7 1.8 2.1 2.5 2.0 2.2 2.7 3.2 3.4 3.1 2.7 4.5 3.7 8.0 8.0 8.0 16.0 20.0 25.0 35.0 35.0 50.0 50.0 20.0 20.0 20.0 25.0 45.0 60.0 70.0 200.0 100.0 200.0 0.25 0.31 0.54 0.76 1.47 1.90 2.75 3.20 4.93 5.97 4.1 4.1 5.5 6.3 9.0 10.3 13.0 15.5 23.0 24.0

40

Three-phase brake motors 230/400 V Protection IP 54

Series FA-FC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

3000 min-1 (2 poles)

63 A2 63 B2 71 A2 71 B2 80 A2 80 B2 90S A2 90L B2 100L A2 112M A2 132S A2 132M B2 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 2740 2770 2820 2820 2830 2840 2850 2860 2850 2910 2910 2930 0.60 0.70 1.15 1.60 1.90 2.60 3.40 5.00 6.20 8.20 12.00 14.80 56 66 68 71 76 77 79 80 81 85 83 86 0.78 0.78 0.69 0.70 0.75 0.79 0.81 0.79 0.86 0.83 0.80 0.85 0.63 0.86 1.25 1.86 2.53 3.70 5.03 7.34 10.00 13.13 18.04 24.40 2.7 3.2 3.6 3.6 3.6 3.7 2.7 3.9 2.8 2.9 2.9 3.2 3 3 3.7 3.5 3.6 3.8 3.1 4 3.1 3 3.3 3.4 7.5 7.5 7.5 7.5 15 15 25 25 45 60 100 100 3.5 4.5 4.6 4.7 5.7 6.5 5.8 6.9 6.2 7.8 6.5 7 0.20 0.23 0.54 0.69 1.15 1.37 1.73 2.70 4.87 9.30 19.65 26.25 3000 3000 2900 2300 1500 1400 1200 1100 950 820 500 470 5.1 5.6 7.3 7.9 11.7 13.2 17.0 19.0 23.6 41.2 52.0 57.0

* Number of starts per hour permitted under no load

41

Three-phase brake motors 230/400 V - 50 Hz Protection IP 54

Series FA-FC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

1500 min-1 (4 poles)

63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 90L C4 100L A4 100L B4 112M A4 132S A4 132M B4 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 3.00 4.00 5.50 7.50 1350 1350 1370 1380 1380 1390 1410 1410 1410 1410 1410 1430 1450 1450 0.46 0.70 0.69 1.18 1.38 2.00 2.60 3.60 4.50 5.10 7.10 9.00 11.90 16.00 54 53 67 68 72 72 79 79 79 80 80 84 87 87 0.69 0.70 0.77 0.67 0.80 0.75 0.77 0.76 0.73 0.78 0.80 0.76 0.77 0.78 0.85 1.27 1.74 2.56 3.80 5.15 7.45 10.16 12.20 14.90 18.04 26.40 36.20 49.40 2 2 2 2.2 1.9 2.6 2.3 2.4 3.1 2.4 2.9 3.1 2.3 2.8 2 2 2.1 2.3 2.2 2.2 2.6 2.6 3.1 2.6 3.3 3.6 2.6 3 7.5 7.5 7.5 7.5 15 15 25 25 25 45 45 60 100 100 2.4 2.3 3.4 4 3.9 3.9 4.6 4.8 5.2 4.8 6.5 6.6 5.4 6.3 0.38 0.47 0.81 1.14 3.35 3.68 4.13 4.80 5.58 7.40 8.85 15.85 39.10 42.90 5500 5500 5000 5000 4700 4500 3900 3800 3700 2500 2400 1800 1200 1000 5.1 5.6 6.7 6.9 11.7 12.6 15.8 18.3 19.5 23.9 28.0 43.0 52.0 62.0

* Number of starts per hour permitted under no load

42

Three-phase brake motors 230/400 V - 50 Hz Protection IP 54

Series FA-FC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

1000 min-1 (6 poles)

63 A6 63 B6 71 A6 71 B6 80 A6 80 B6 90S A6 90L B6 100L A6 100L B6 112M A6 132S A6 132M C6 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 3.00 5.50 890 870 850 870 880 900 910 900 935 935 945 960 950 0.67 0.70 0.70 1.00 1.35 1.74 2.20 3.30 4.10 4.90 6.30 7.70 12.97 40 45 51 53 56 65 68 69 75 76 79 84 85 0.49 0.55 0.73 0.68 0.71 0.70 0.72 0.70 0.70 0.70 0.64 0.67 0.72 0.96 1.32 2.00 2.74 4.00 5.83 7.87 11.67 15.30 18.40 22.23 29.84 55.30 2.5 1.3 1.4 2.2 2.2 2 2.2 1.9 2.1 2.3 2.7 2.5 2.1 2.5 2 2.1 2.1 2.1 2.1 2.1 2 2.5 2.5 2.7 2.4 3.1 7.5 7.5 7.5 7.5 15 15 25 25 45 45 60 100 100 1.7 1.8 2.1 2.7 2.7 3 3.7 3.1 4.2 4.4 4.6 5.4 5.8 0.45 0.60 0.90 1.40 1.98 2.67 4.20 5.25 9.60 11.85 16.50 41.13 52.50 5700 5500 5500 5000 4700 4300 3800 3600 2600 2500 1700 1200 800 4.1 4.6 5.7 6.3 8.8 10.5 13.0 16.5 21.0 30.2 40.0 45.0 60.0

* Number of starts per hour permitted under no load

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN

Pull-up torque ratio MM/MN

Max. braking torque Mf max (Nm)

Starting current ratio IA/IN

Moment of inertia

Starts/h

Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

750 min-1 (8 poles)

63 B8 71 B8 80 A8 80 B8 90S A8 90L B8 100L A8 100L B8 112M B8 132S A8 132M B8 0.08 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 630 670 670 680 670 670 690 690 710 710 705 0.48 0.69 0.92 1.28 1.40 2.20 2.50 3.90 4.50 6.80 7.70 45 49 47 50 61 62 67 68 76 73 80 0.53 0.51 0.60 0.56 0.62 0.58 0.65 0.60 0.63 0.64 0.70 1.21 1.71 2.56 3.50 5.30 7.84 10.40 15.20 20.20 29.60 40.60 1.3 2.5 1.8 1.9 1.7 1.6 1.7 1.8 1.7 1.6 1.5 1.8 2.9 2 2.1 2.2 2.1 1.9 2 2.4 2 2.2 7.5 7.5 15 15 25 25 45 45 60 100 100 1.3 2.4 2.1 2.3 2.5 2.5 2.9 2.9 3.9 3.7 3.5 0.60 1.35 1.98 2.67 4.20 5.25 9.60 11.85 16.50 41.13 52.50 6000 5700 5500 5500 5000 5000 4700 4500 3900 3800 3700 5.6 7.9 11.7 12.2 17.0 19.3 27.4 30.2 40.0 45.0 60.0

* Number of starts per hour permitted under no load

43

Pole-changing brake motors 400 V - 50 Hz Protection IP 54

Series FBA-FBC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

3000/1500 min-1 (2/4 poles) - Dahlander connection

63 A2/4 63 B2/4 71 A2/4 71 B2/4 80 A2/4 80 B2/4 90S A2/4 90L B2/4 0.16 0.11 2700 1270 0.22 0.15 2710 1280 0.30 0.20 2750 1330 0.45 0.30 2780 1350 0.60 0.45 2800 1380 0.80 0.60 2820 1390 1.40 1.00 2830 1400 1.80 1.25 2830 1390 0.56 0.46 0.70 0.58 0.90 0.72 1.30 1.06 1.78 1.49 2.22 1.74 3.66 2.86 4.57 3.38 5.95 4.74 7.74 6.86 10.08 8.14 12.57 11.14 16.32 14.83 57 53 58 55 60 57 63 59 64 67 65 70 68 70 71 73 73 74 75 77 75 79 77 81 78 80 0.72 0.65 0.78 0.68 0.80 0.70 0.79 0.69 0.76 0.65 0.80 0.71 0.81 0.72 0.80 0.73 0.83 0.74 0.82 0.71 0.84 0.74 0.82 0.72 0.85 0.73 0.55 0.83 0.77 1.12 1.04 1.43 1.54 2.12 2.05 3.11 2.71 4.12 4.73 6.82 6.07 8.58 8.35 12.19 10.94 17.73 14.48 22.35 18.05 30.69 24.53 40.78 1.3 1.6 2.2 2.5 2.2 2.0 2.1 2.4 2.3 2.5 2.5 2.6 2.4 2.3 2.3 2.2 2.4 2.2 2.1 2.3 2.2 2.3 2.4 2.5 2.2 2.5 1.7 1.4 2.5 3.0 2.4 2.9 2.3 2.7 2.2 2.4 2.6 2.8 2.7 2.9 2.7 2.8 2.6 2.5 2.7 2.6 2.8 2.5 2.6 2.4 2.8 2.6 7.5 7.5 7.5 7.5 15 15 25 25 45 45 60 100 100 2.4 2.6 3.3 3.5 3.1 3.3 3.4 3.3 3.2 3.4 3.4 3.6 3.5 3.6 3.5 3.4 4.3 4.2 4.5 4.4 5.6 5.5 6.3 6.5 6.5 7.0 0.38 0.47 0.81 1.14 3.35 3.68 4.13 5.58 7.40 8.85 15.85 39.10 42.90 3000 3000 2900 2300 1500 1400 1200 1100 950 820 500 470 400 5.1 5.1 6.7 6.9 11.7 12.6 15.8 19.5 22.7 25.0 41.2 52.0 62.0

100L A2/4 2.50 1.80 2860 1410 100L B2/4 3.30 2.60 2880 1400 112M A2/4 4.40 3.30 2900 1410 132S A2/4 5.50 4.50 2910 1400 132M B2/4 7.50 6.00 2920 1405

* Number of starts per hour permitted under no load

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN

Pull-up torque ratio MM/MN

Max. braking torque Mf max (Nm)

Starting current ratio IA/IN

Moment of inertia

Starts/h

Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

1500/750 min-1 (4/8 poles) - Dahlander connection

63 A4/8 71 B4/8 80 A4/8 80 B4/8 90S A4/8 90L B4/8 0.09 0.04 1280 620 0.15 0.09 1305 610 0.37 0.20 1320 630 0.55 0.30 1350 650 0.75 0.37 1380 670 0.90 0.50 1400 680 0.32 0.24 0.52 0.53 1.20 1.09 1.69 1.50 2.10 1.53 2.39 1.89 3.50 2.59 3.80 2.98 4.03 3.26 5.29 4.25 8.89 7.08 10.34 8.77 54 40 56 40 59 42 60 45 65 53 68 56 73 60 75 64 77 67 78 69 77 66 80 72 0.76 0.60 0.75 0.61 0.76 0.63 0.78 0.64 0.79 0.66 0.80 0.68 0.79 0.65 0.81 0.68 0.79 0.66 0.77 0.64 0.78 0.68 0.82 0.64 0.67 0.62 1.09 1.40 2.67 3.03 3.89 4.41 5.19 5.27 6.14 7.02 9.52 9.76 10.84 12.46 11.43 13.64 14.90 18.00 24.70 30.45 31.06 37.66 1.3 1.6 2.2 2.5 2.2 2.0 2.1 2.4 2.3 2.5 2.5 2.6 2.4 2.3 2.3 2.2 2.4 2.2 2.1 2.3 2.2 2.3 2.4 2.5 1.7 1.4 2.5 3.0 2.4 2.9 2.3 2.7 2.2 2.4 2.6 2.8 2.7 2.9 2.7 2.8 2.6 2.5 2.7 2.6 2.8 2.5 2.6 2.4 7.5 7.5 15 15 25 25 45 45 60 60 100 100 2.1 2.0 2.4 2.6 2.6 2.7 2.7 2.5 3.0 3.2 3.0 3.3 3.5 3.6 3.5 3.4 3.9 3.6 4.6 4.0 5.0 4.2 5.2 4.4 0.47 1.14 3.35 3.68 4.13 4.80 5.58 9.60 11.85 16.50 41.13 52.50 5500 5000 4700 4500 3900 3800 2500 2400 1800 1200 1200 1000 5.6 6.9 11.7 12.6 15.8 18.3 23.9 28.0 43.0 47.0 52.0 62.0

100L A4/8 1.40 0.70 1405 685 100L B4/8 1.60 0.90 1410 690 112M A4/8 1.70 1.00 1420 700 112M A4/8 2.20 1.30 1410 690 132S A4/8 3.70 2.20 1430 690 132M B4/8 4.70 2.80 1445 710

* Number of starts per hour permitted under no load

44

Pole-changing brake motors 230/400 V - 50 Hz Protection IP 54

Series FBA-FBC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

1500/1000 min-1 (4/6 poles) - Separate windings

63 A4/6 71 B4/6 80 A4/6 80 B4/6 90S A4/6 90L B4/6 0.18 0.04 1320 840 0.22 0.15 1360 860 0.37 0.26 1380 870 0.55 0.45 1380 880 0.75 0.50 1400 905 1.10 0.75 1410 910 0.68 0.17 0.69 0.61 1.05 0.98 1.50 1.56 1.90 1.70 2.65 2.44 3.56 2.73 4.00 3.73 5.86 5.09 9.02 7.36 11.95 10.49 54 53 63 55 67 60 69 63 73 65 75 67 77 71 80 74 81 74 80 75 82 76 0.70 0.64 0.73 0.65 0.76 0.64 0.77 0.66 0.78 0.65 0.80 0.66 0.79 0.67 0.81 0.68 0.79 0.69 0.80 0.68 0.81 0.67 1.30 0.45 1.54 1.66 2.56 2.85 3.80 4.88 5.12 5.27 7.45 7.87 10.19 9.54 12.10 13.64 17.36 18.78 26.80 26.98 36.60 37.99 2.4 1.5 2.3 1.6 2.4 1.7 2.5 1.7 2.6 1.7 2.5 1.6 2.7 1.7 2.9 1.8 3.0 2.0 3.2 2.2 3.1 2.1 2.3 1.6 2.2 1.5 2.5 1.7 2.6 1.8 2.7 2.0 2.8 2.2 2.6 2.3 2.8 2.5 3.0 2.6 3.1 2.7 3.2 2.8 7.5 7.5 15 15 25 25 45 60 60 100 100 2.1 1.8 2.3 1.9 2.4 2.0 3.2 2.8 3.4 3.0 3.7 3.2 4.1 3.8 4.4 4.0 5.5 4.4 5.7 4.8 5.6 4.4 0.47 1.14 3.35 3.68 4.20 5.25 11.85 16.50 19.50 41.13 52.50 5500 5000 4700 4500 3900 3800 2400 1800 1200 1200 1000 5.6 6.9 11.7 12.6 15.8 18.3 28.0 43.0 47.0 52.0 62.0

100L A4/6 1.50 0.90 1405 900 112M A4/6 1.80 1.30 1420 910 112M B4/6 2.60 1.80 1430 915 132S A4/6 4.00 2.60 1425 920 132M B4/6 5.50 3.70 1435 930

* Number of starts per hour permitted under no load

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN

Pull-up torque ratio MM/MN

Max. braking torque Mf max (Nm)

Starting current ratio IA/IN

Moment of inertia

Starts/h

Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

1000/750 min-1 (6/8 poles) - Separate windings

63 A6/8 71 B6/8 80 A6/8 90S A6/8 90L B6/8 0.07 0.037 840 600 0.18 0.09 0.25 0.18 0.37 0.25 0.55 0.37 845 620 860 640 870 660 890 680 900 670 905 690 910 700 920 700 0.30 0.21 0.74 0.48 0.94 0.89 1.26 1.15 1.77 1.65 2.25 2.21 3.07 2.88 3.92 3.72 5.51 4.71 52 46 54 48 58 53 63 56 67 59 73 63 76 67 79 70 80 73 0.64 0.55 0.65 0.56 0.66 0.55 0.67 0.56 0.67 0.55 0.66 0.57 0.68 0.56 0.70 0.61 0.72 0.63 0.79 0.59 2.03 1.38 2.77 2.68 4.06 3.62 5.90 5.20 7.96 7.84 11.60 10.38 15.74 15.00 22.84 20.46 2.0 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.8 2.6 1.9 2.4 2.0 2.6 2.3 2.4 2.1 1.4 1.3 1.6 1.5 1.7 1.8 2.2 2.1 2.3 2.1 2.5 2.2 2.3 2.5 3.0 2.8 3.1 2.7 7.5 7.5 15 25 25 45 60 100 100 2.1 1.8 2.3 1.9 2.7 2.5 3.2 2.8 3.5 3.1 3.8 3.3 4.6 4.2 5.5 4.4 5.5 4.6 0.47 1.14 3.68 4.20 5.25 11.85 16.50 41.13 52.50 5500 5000 4300 3800 3600 2500 1700 1200 800 4.6 6.3 10.5 13.0 16.5 30.2 40.0 45.0 60.0

100L B6/8 0.75 0.55 112M B6/8 1.10 0.75 132S A6/8 1.50 1.10 132M B6/8 2.20 1.50

* Number of starts per hour permitted under no load

45

Pole-changing brake motors 400 V - 50 Hz Protection IP 54

Series FBA-FBC

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n* 1/h

kg

3000/750 min-1 (2/8 poles) - Separate windings

63 A2/8 71 B2/8 80 A2/8 90S A2/8 90L B2/8 100L A2/8 100L B2/8 112M A2/8 132S A2/8 132M B2/8 0.18 0.06 2760 600 0.30 0.09 2770 620 0.55 0.12 2800 640 0.75 0.18 2810 675 1.10 0.30 2810 680 1.50 0.37 2815 690 1.80 0.45 2810 680 2.20 0.55 2820 700 3.00 0.75 2825 710 4.00 1.10 2830 715 0.59 0.36 0.92 0.48 1.53 0.59 1.89 0.76 2.62 1.26 3.30 1.33 3.91 1.59 4.66 1.77 6.06 2.31 8.18 3.25 56 40 59 43 64 47 69 54 74 56 78 63 80 65 83 70 84 71 84 73 0.78 0.60 0.80 0.63 0.81 0.62 0.83 0.63 0.82 0.61 0.84 0.64 0.83 0.63 0.82 0.64 0.85 0.66 0.84 0.67 0.62 0.95 1.03 1.39 1.87 1.79 2.55 2.54 3.74 4.21 5.08 5.12 6.12 6.32 7.45 7.50 10.14 10.09 13.50 14.69 2.4 1.5 2.3 1.6 2.4 1.7 2.5 1.7 2.6 1.7 2.5 1.6 2.7 1.7 2.9 1.8 3.0 2.0 3.2 2.2 2.3 1.6 2.2 1.5 2.5 1.7 2.6 1.8 2.7 2.0 2.8 2.2 2.6 2.3 2.8 2.5 3.0 2.6 3.1 2.7 7.5 7.5 15 25 25 45 45 60 100 100 2.1 1.8 2.3 1.9 2.4 2.0 3.2 2.8 3.4 3.0 3.7 3.2 4.1 3.8 4.4 4.0 5.5 4.4 5.7 4.8 0.47 1.14 3.68 3.35 3.68 7.40 8.85 15.58 39.10 42.90 5500 5000 4300 3800 3600 2600 2500 1700 1200 800 4.6 6.3 10.5 13.0 16.5 21.0 30.2 40.0 45.0 60.0

* Number of starts per hour permitted under no load

46

Smaller-sized brake motors 230/400 V - 50 Hz Protection IP 54

Series FS

Type Rated output Rated speed Rated current at IN 400V(A) Efficiency Power factor Breakaway torque Mn (Nm) Breakaway torque ratio MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Moment of inertia Weight

kW

min-1

100%

cos

10-3 kgm2

kg

3000 min-1 (2 poles)

63 A2 63 B2 71 A2 71 B2 80 A2 80 B2 90S A2 90L B2 100L A2 112M A2 132M A2 132M B2 0.18 0.25 0.37 0.55 0.75 1.10 1.50 2.20 3.00 4.00 5.50 7.50 2740 2770 2820 2820 2830 2840 2850 2860 2850 2910 2910 2930 0.60 0.70 1.15 1.60 1.90 2.60 3.40 5.00 6.20 8.20 12.00 14.80 56 66 68 71 76 77 79 80 81 85 83 86 0.78 0.78 0.69 0.70 0.75 0.79 0.81 0.79 0.86 0.83 0.80 0.85 0.63 0.86 1.25 1.86 2.53 3.70 5.03 7.34 10.00 13.13 18.04 24.40 2.7 3.2 3.6 3.6 3.6 3.7 2.7 3.9 2.8 2.9 2.9 3.2 3 3 3.7 3.5 3.6 3.8 3.1 4 3.1 3 3.3 3.4 2.50 2.50 5.50 5.50 9.00 9.00 9.50 9.50 12.00 12.50 17.00 17.00 3.5 4.5 4.6 4.7 5.7 6.5 5.8 6.9 6.2 7.8 6.5 7 0.18 0.21 0.48 0.59 1.02 1.16 1.54 2.43 4.12 8.57 18.40 22.45 5.1 5.6 7.0 7.6 11.2 12.7 15.2 17.2 24.1 39.7 49.5 54.5

Type

Rated output

Rated speed

Rated current at IN 400V(A)

Efficiency

Power factor

Breakaway torque Mn (Nm)

Breakaway torque ratio MA/MN

Pull-up torque ratio MM/MN

Max. braking torque Mf max (Nm)

Starting current ratio IA/IN

Moment of inertia

Weight

kW

min-1

100%

cos

10-3 kgm2

kg

1500 min-1 (4 poles)

63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 90L C4 100L A4 100L B4 112M A4 132S A4 132M B4 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 3.00 4.00 5.50 7.50 1350 1350 1370 1380 1380 1390 1410 1410 1410 1410 1410 1430 1450 1450 0.46 0.70 0.69 1.18 1.38 2.00 2.60 3.60 4.50 5.10 7.10 9.00 11.90 16.00 54 53 67 68 72 72 79 79 79 80 80 84 86 87 0.69 0.70 0.77 0.67 0.80 0.75 0.77 0.76 0.73 0.78 0.80 0.76 0.77 0.78 0.85 1.27 1.74 2.56 3.80 5.15 7.45 10.16 12.20 14.90 18.04 26.40 36.20 49.40 2 2 2 2.2 1.9 2.6 2.3 2.4 3.1 2.4 2.9 3.1 2.3 2.8 2 2 2.1 2.3 2.2 2.2 2.6 2.6 3.1 2.6 3.3 3.6 2.6 3 2.50 2.50 4.00 4.00 9.00 9.00 9.50 9.50 9.50 12.00 12.00 12.50 17.00 17.00 2.4 2.3 3.4 4 3.9 3.9 4.6 4.8 5.2 4.8 6.5 6.6 5.4 6.3 0.27 0.36 0.75 0.98 2.90 3.35 3.87 4.60 5.23 6.88 8.34 14.56 33.20 40.40 5.1 5.6 6.4 7.6 11.2 12.1 14.0 16.5 17.7 22.2 24.5 40.7 52.0 62.0

47

Single-phase motors with high starting torque with starting and running capacitor 230 V - 50 Hz Protection IP 54

Series FME

Typ Rated output Rated speed Rated current IN 400V(A) Efficiency Power factor Breakaway Breakaway Pull-up torque torque torque ratio ratio Mn (Nm) MA/MN MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Running Starting Moment capacitor capacitor of inertia C (µF) C Start (µF) Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n 1/h

kg

3000 min-1 (2 poles)

63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 100L A4 100L B4 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 1370 1290 1340 1370 1370 1390 1353 1380 1380 1410 1.32 2.00 2.26 3.00 3.70 5.40 7.23 10.10 11.74 15.16 46 47.4 53.4 60.4 65.9 67.4 67.2 68 71.2 72.6 0.85 0.85 0.90 0.87 0.97 0.89 0.95 0.95 0.95 0.88 0.84 1.33 1.78 2.57 3.82 5.14 7.59 10.44 12.60 15.24 3.0 2.6 2.3 2.5 2.5 2.5 2.5 2.2 2.2 2.5 1.4 1.2 1.5 1.6 1.4 1.7 1.6 1.7 1.8 2.1 7.5 7.5 7.5 7.5 15 15 25 25 45 45 2.0 1.8 2.2 2.7 3.1 3.2 3.0 2.7 3.2 3.2 8.0 8.0 16.0 16.0 20.0 25.0 35.0 60.0 50.0 60.0 20.0 20.0 20.0 25.0 45.0 60.0 70.0 70.0 100.0 180.0 0.38 0.47 0.81 1.14 3.35 3.68 4.13 5.58 7.40 8.85 5500 5200 4200 4100 3600 3300 2500 2300 1800 1800 5.1 5.1 7.1 7.9 11.7 13.0 17.0 19.5 27.0 28.0

Single-phase brake motors with running capacitor 230 V - 50 Hz Protection IP 54

Series FMC

Typ Rated output Rated speed Rated current IN 400V(A) Efficiency Power factor Breakaway Breakaway torque torque ratio Mn (Nm) MA/MN Pull-up torque ratio MM/MN Max. braking torque Mf max (Nm) Starting current ratio IA/IN Running capacitor C (µF) Moment of inertia Starts/h Weight

kW

min-1

100%

cos

10-3 kgm2

n 1/h

kg

1500 min-1 (4 poles)

63 A4 63 B4 71 A4 71 B4 80 A4 80 B4 90S A4 90L B4 100L A4 100L B4 0.12 0.18 0.25 0.37 0.55 0.75 1.10 1.50 1.80 2.20 1370 1290 1340 1370 1370 1390 1353 1380 1380 1410 1.32 2.00 2.26 3.00 3.70 5.40 7.23 10.10 11.74 15.16 46 47.4 53.4 60.4 65.9 67.4 67.2 68 71.2 72.6 0.85 0.85 0.90 0.87 0.97 0.89 0.95 0.95 0.95 0.88 0.84 1.33 1.78 2.57 3.82 5.14 7.59 10.44 12.60 15.24 1.3 0.8 0.7 0.8 0.8 0.7 0.7 0.9 0.7 0.6 1.4 1.2 1.5 1.6 1.4 1.7 1.6 1.7 1.8 2.1 7.5 7.5 7.5 7.5 15 15 25 25 45 45 2.0 1.8 2.2 2.7 3.1 3.2 3.0 2.7 3.2 3.2 8.0 8.0 16.0 16.0 20.0 25.0 35.0 60.0 50.0 60.0 0.38 0.47 0.81 1.14 3.35 3.68 4.13 5.58 7.40 8.85 5500 5200 4200 4100 3600 3300 2500 2300 1800 1800 5.1 5.1 7.1 7.9 11.7 13.0 17.0 19.5 27.0 28.0

48

Forced ventilated motors

L

HD

LB

Series TSV

Electrical data

TYPE Fan W V A MC/h dB/A Hz

Dimensions

TYPE L LB

71 80 90 S/L 90 S/L 100 L 100 L 112 M 132 S/M

A2S 107 A2S 130 A2E 170 A2D 170 A2E 170 A2D 170 A2D 200 A2D 200

20 40 50 50 50 50 60 60

230* 230* 230* 230/400 230* 230/400 230/400 230/400

0.12 0.18 0.22 0.2/0.12 0.22 0.2/0.12 0.26/0.15 0.26/0.15

160 360 500 500 500 500 600 600

42 49 59 59 59 59 67 67

50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60

71 80 90 S 90 L 100 L 112 M 132 S 132 M

305 350 392 416 452 476 539 577

275 310 342 366 392 416 459 497

* single-phase supply

Note Data omitted are identical to those of the corresponding version (T) *F: Dimensions of forced ventilated motors, see page 50

49

Dimensions Three-phase and single-phase motors Series T-BP-M-ME-FS

LC L AL AF E AD

Mounting IM B3

GA

EA

F

DB

AC

HD

AD

DA

BB C B LB CA

HA

K

BA

H

GD

D

AA A AB

K1

Note: Sectioning refers to capacitors of series M and ME

Type H A B C K AB BB CA AD HD AC HC HA K1 L LB LC AL AF* BA AA D DA E EA F GD GA DB

56 63 71 80 90 S 90 L 100 L 112M 132S 132M

56

90

71 80 90

36 40 45 50 56 56 63 70 89 89

6 7 7 9 9 9 12 12 12 12

107

90

65 72 86 85 98 98 105 118 143 143

94 150 98 161 107 178 122 202 129 219 129 219 140 240 160 272 177 309 177 309

110 124 137 156 176 176 195 219 258 258

114 126 143 162 182 182 200 225 261 261

8 10 12 13 14 14 14 15 16 16

12 12 17 18 18 18 20 21 21 21

188 168 211 191 247 217 275 235 302 252 326 276 366 306 385 325 449 369 487 407

212 238 281 315 354 378 429 448 532 570

62 66 76 85 86 86 96 97 117 117

70 70 70 84 84 84 84 84 92 92

22 26 22 31 32 32 40 38 44 44

22 26 30 32 39 39 42 42 58 58

9 11 14 19 24 24 28 28 38 38

20 23 30 40 50 50 60 60 80 80

HC

3 4 5 6 8 8 8 8 10 10

3 10.2 4 12.5 5 16

M4 M4 M5 M6 M8 M8

63 100 71 112

126 105 144 109 155 130 184 130 184 154 200 176 220 176 260 178 260 216

80 125 100 90 140 100 90 140 125 100 160 140 112 190 140 132 216 140 132 216 178

6 21.5 7 7 7 7 27 27

31 M10 31 M10

8 41.5 M12 8 41.5 M12

Note Series BP frame sizes 63 to 132 Single-phase motors series M frame sizes 56 to 100L Single-phase motors series ME frame sizes 63 to 100L Brake motors series FS frame sizes 63 to 132M *AF: Dimensions for brake motors series FS see page 53

50

Dimensions Three-phase and single-phase motors Series T-BP-M-ME-FS

L AL AF T

Mounting IM B5, IM B35

LC

GA

DB

E

EA

AC

F

S

N

D

P

GD

LA E LB

DA

HD

C

B

CA

HA

K

H

K1 A

Note: Sectioning refers to capacitors of series M and ME

Type M N P T LA S H A B C K CA HD AC HA K1 L LB LC AL AF* D DA E EA F GD GA DB

56 63 71 80 90S 90L 100L 112M 132S 132M

100 115

80 120 95 140

2.5 3.0 3.5 3.5 3.5 3.5 4.0 4.0 4.0 4.0

5.5 10 10 12 12 12 14 14 14 14

7.0 9.5 9.5 11.5 11.5 11.5

56 63 71 80 90 90

90 100 112 125 140 140 160 190 216 216

71 80 90 100 100 125 140 140 140 178

36 40 45 50 56 56 63 70 89 89

6 7 7 9 9 9 12 12 12 12

65 150 72 161 86 178 85 202 98 219 98 219 105 240 118 272 143 309 143 309

110 124 137 156 176 176 195 219 258 258

8 10 12 13 14 14 14 15 16 16

12 12 17 18 18 18 20 21 21 21

188 211 247 275 302 326 366 385 449 487

168 212 191 238 217 281 235 315 252 354 276 378 306 429 325 448 369 532 407 570

62 66 76 85 86 86 96 97 117 117

70 70 70 84 84 84 84 84 92 92

9 11 14 19 24 24 28 28 38 38

M

20 23 30 40 50 50 60 60 80 80

3 4 5 6 8 8 8 8 8 8

3 4 5 6 8 8 8 8 10 10

10.2 12.5 16 21.5 27 27

M4 M4 M5 M6 M8 M8

130 110 160 165 130 200 165 130 200 165 130 200 215 180 250 215 180 250 265 230 300 265 230 300

14.0 100 14.0 112 14.0 132 14.0 132

31 M10 31 M10 41.5 M12 41.5 M12

Note Series BP frame sizes 63 to 132 Single-phase motors series M frame sizes 56 to 100L Single-phase motors series ME frame sizes 63 to 100L Brake motors series FS frame sizes 63 to 132M *AF: Dimensions for brake motors series FS see page 53

51

Dimensions Three-phase and single-phase motors Series T-BP-M-ME-FS

L AL AF T

Mounting IM B14, IM B34

LC

DB

F

P

N

D

GD

DA

AC

S

GA

EA

M E LB

HD K C B CA H

HA

K1 A

Note: Sectioning refers to capacitors of series M and ME

Type M N P T S H A B C K CA HD AC HA K1 L LB LC AL AF* D DA E EA F GD GA DB

56 63 71 80 90 S 90 L 100 L 112 M 132 S 132 M

65 75 85 100 115 115 130 130 165 165

50 60 70 80 95 95 110 110 130 130

80 90 105 120 140 140 160 160 200 200

2.5 2.5 2.5 3.0 3.0 3.0 3.5 3.5

M5 M5 M6 M6 M8 M8

56 63 71 80 90 90

90 100 112 125 140 140 160 190 216 216

71 80 90 100 100 125 140 140 140 178

36 40 45 50 56 56 63 70 89 89

6 7 7 9 9 9 12 12 12 12

65 72 86 85 98 98 105 118 143 143

150 161 178 202 219 219 240 272 309 309

110 124 137 156 176 176 195 219 258 258

8 10 12 13 14 14 14 15 16 16

12 12 17 18 18 18 20 21 21 21

188 211 247 275 302 326 366 385 449 487

168 191 217 235 252 276 306 325 369 407

212 238 281 315 354 378 429 448

62 66 76 85 86 86 96 97

70 70 70 84 84 84 84 84 92 92

9 11 14 19 24 24 28 28 38 38

20 23 30 40 50 50 60 60 80 80

3 4 5 6 8 8 8 8 8 8

3 4 5 6 8 8 8 8 10 10

10.2 12.5 16 21.5 27 27 31 31 41.5 41.5

M4 M4 M5 M6 M8 M8 M10 M10 M12 M12

M8 100 M8 112

4.0 M10 132 4.0 M10 132

532 117 570 117

Note Series BP frame sizes 63 to 132 Single-phase motors series M frame sizes 56 to 100L Single-phase motors series ME frame sizes 63 to 100L Brake motors series FS frame sizes 63 to 132M *AF: Dimensions for brake motors series FS see page 53

52

Dimensions Brake motors Series FA-FC-FBA-FBC-FMC-FME

Mounting IM B3

LC L AL AF E AD

GA

EA

DB

AC

HD

F

AD

BB C B LB CA

HA

K

BA

H

GD

DA

AA A AB

K1

Type

H

A

B

C

K

AB

BB

CA

AD

HD

AC

HC

HA

K1

L

LB

LC

AL

AF

BA

AA

D DA

E EA

HC

D

F

GD

GA

DB

63 71 80 90S 90L 100L 112M 132S 132M

63 71 80 90 90 100 112 132 132

100 112

80 90

40 45 50 56 56 63 70 89 89

7 7 9 9 9 12 12 12 12

126 105 144 109 155 130 184 130 184 154 200 176 220 176 260 178 260 216

127 140 160 186 185 189 206 230 230

98 107 122 129 129 140 160 177 177

161 178 202 219 219 240 272 309 309

124 137 156 176 176 195 219 258 258

126 143 162 182 182 200 225 261 261

10 12 13 14 14 14 15 16 16

12 17 18 18 18 20 21 21 21

270 305 350 392 416 452 476 539 577

247 295 275 337 310 392 342 444 366 468 392 515 416 539 459 622 497 660

66 76 85 86 86 96 97 117 117

137 152 152 152 152 152 152 123 123

26 22 31 32 32 40 38 44 44

26 30 32 39 39 42 42 58 58

11 14 19 24 24 28 28 38 38

23 30 40 50 50 60 60 80 80

4 5 6 8 8 8 8 10 10

4 5 6 7 7 7 7 8 8

12.5 16 21.5 27 27 31 31

M4 M5 M6 M8 M8 M10 M10

125 100 140 100 140 125 160 140 190 140 216 140 216 178

41.5 M12 41.5 M12

Note Series FMC frame sizes 56 to 100L Series FME frame sizes 63 to 100L Series FBA-FBC frame sizes 63 to 132M

53

Dimensions Brake motors Series FA-FC-FBA-FBC-FMC-FME

LC L AL T

Mounting IM B5, IM B35

GA F DB N D P

E

EA AC

S

GD

LA E LB

DA

HD

C

B

CA

HA

K

H

K1 A

Type

M

N

P

T

LA

S

H

A

B

C

K

CA

HD

AC

HA

K1

L

LB

LC

AL

AF DA

D EA

M

E

F

GD

GA

DB

63 71 80 90S 90L 100L 112M 132S 132M

115

95

140 160 200 200 200 250 250 300 300

3.0 3.5 3.5 3.5 3.5 4.0 4.0 4.0 4.0

10 10 12 12 12 14 14 14 14

9.5 9.5 11.5 11.5 11.5

63 71 80 90 90

100 112 125 140 140 160 190 216 216

80 90 100 100 125 140 140 140 178

40 45 50 56 56 63 70 89 89

7 7 9 9 9 12 12 12 12

127 140 160 186 185 189 206 230 230

161 178 202 219 219 240 272 309 309

124 137 156 176 176 195 219 258 258

10 12 13 14 14 14 15 16 16

12 17 18 18 18 20 21 21 21

270 305 350 392 416 452 476 539 577

247 275 310 342 366 392 416 459 497

295 337 392 444 468 515 539

66 76 85 86 86 96 97

137 152 152 152 152 152 152 123 123

11 14 19 24 24 28 28 38 38

23 30 40 50 50 60 60 80 80

4 5 6 8 8 8 8 8 8

4 5 6 8 8 8 8 10 10

12.5 16 21.5 27 27 31 31

M4 M5 M6 M8 M8 M10 M10

130 110 165 130 165 130 165 130 215 180 215 180 265 230 265 230

14.0 100 14.0 112 14.0 132 14.0 132

622 117 660 117

41.5 M12 41.5 M12

Note Series FMC frame sizes 56 to 100L Series FME frame sizes 63 to 100L Series FBA-FBC frame sizes 63 to 132M

54

Dimensions Brake motors Series FA-FC-FBA-FBC-FMC-FME

LC L AL AF T

Mounting IM B14, IM B34

F DB

GD

DA

AC

P

N

D

S

GA

EA

M E LB

HD K C B CA H

HA

K1 A

Type

M

N

P

T

S

H

A

B

C

K

CA

HD

AC

HA

K1

L

LB

LC

AL

AF

D DA

E EA

F

GD

GA

DB

63 71 80 90S 90L 100L 112M 132S 132M

75 85 100 115 115 130 130 165 165

60 70 80 95 95 110 110 130 130

90 105 120 140 140 160 160 200 200

2.5 2.5 3.0 3.0 3.0 3.5 3.5

M5 M6 M6 M8 M8 M8 M8

63 71 80 90 90 100 112 132 132

100 112 125 140 140 160 190 216 216

80 90 100 100 125 140 140 140 178

40 45 50 56 56 63 70 89 89

7 7 9 9 9 12 12 12 12

127 140 160 186 185 189 206 230 230

161 178 202 219 219 240 272 309 309

124 137 156 176 176 195 219 258 258

10 12 13 14 14 14 15 16 16

12 17 18 18 18 20 21 21 21

270 305 350 392 416 452 476 539 577

247 275 310 342 366 392 416 459 497

295 337 392 444 468 515 539 622 660

66 76 85 86 86 96 97 117 117

137 137 152 152 152 152 152 123 123

11 14 19 24 24 28 28 38 38

23 30 40 50 50 60 60 80 80

4 5 6 8 8 8 8 8 8

4 5 6 8 8 8 8 10 10

12.5 16 21.5 27 27 31 31

M4 M5 M6 M8 M8 M10 M10

4.0 M10 4.0 M10

41.5 M12 41.5 M12

Note Series FMC frame sizes 56 to 100L Series FME frame sizes 63 to 100L Series FBA-FBC frame sizes 63 to 132M

55

56

No. e . . . . . t. . s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

57

58

59

Factory ICME S.p.A. Via S. Barbara, 143 I - 48010 Fusignano (Ravenna) ­ Italy Tel. + 39/0545 52 802 Fax + 39/0545 52 403 e-mail: [email protected]

Headquarters Lafert S.p.A. Via J.F. Kennedy, 43 I ­ 30027 San Donà di Piave (Venezia) ­ Italy Tel. +39/0421-229 611 Fax +39/0421-220 655 e-mail: [email protected]

05/2002

stampa Grafiche Morandi, Fusignano

www.lafert.com

Information

60 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

158717


You might also be interested in

BETA
untitled
ENGLISH_TRIF_21e_100105
untitled