Read EMC CLARiiON Software Installation Guide text version

EMC CLARiiON Software

Installation Guide

P/N 300-001-504 REV A03 January 17, 2005

This guide describes how to use the Software Installation Wizard (also know as the Smart Installation Wizard) to install the following software on an EMC® CX-Series storage system:

FLARETM OE 02.07.xxx.5.yyy or higher bundle Navisphere® Manager Enabler Access LogixTM Enabler Analyzer Enabler MirrorViewTM Enabler (synchronous MirrorView) MirrorView/A Enabler (asynchronous MirrorView) SAN CopyTM Enabler SnapViewTM Enabler

It also describes how to install Navisphere Management Server and Navisphere UIs for Microsoft Windows® hosts. Read this document completely before installing any of this software.

For information on installing CLARiiON server software or the FC4700 storage-system software, see Finding Current Information on page 24.

Topics in this document include

Storage-System and Server Requirements.........................................2 Supported Software Installation Revisions .......................................4 CX-Series Software Media....................................................................6 Configuration Prerequisites ...............................................................10 Installing Software on a CX-Series Storage System........................14 Installing and Uninstalling .exe Files on a Windows Server.........20 Adding a CX200 Storage System to a Domain................................23 Using Enabled Software .....................................................................24 Finding Current Information.............................................................24

1

Storage-System and Server Requirements

Storage-System and Server Requirements

If the storage-system requirements below are met, you can use the Software Installation Wizard to install the software listed in Table 1 on page 4 on any CX-Series storage system except a CX200LC. If any of these conditions are not met, an authorized service provider must install the software.

To view the software that is running on your storage system, open Navisphere Manager or Manager Base. Right-click the storage-system icon and click Properties. Select the Software tab to view the Active software files that are loaded on the storage system.

CX200 Storage-System Requirements The storage system is not part of a Celerra® configuration. FLARE OE version 2.16 or higher is installed on the storage system or FLARE OE version 2.05, 2.06, or 2.07 is installed on the storage system and the storage system does not contain a DAE2 with ATA drives. CX300 Storage-System Requirements The storage system is not part of a CLARiiON® Data Library or Celerra® configuration. FLARE OE version 2.16 or higher is installed on the storage system or FLARE OE version 2.06 or 2.07 is installed on the storage system, the storage system does not contain a DAE2 with ATA drives, and SnapViewTM software is not installed on the storage system. CX400 or CX600 Storage-System Requirements The storage system is not part of a Celerra® configuration. FLARE OE version 2.16 or higher is installed on the storage system or FLARE OE version 2.07 is installed on the storage system, the storage system does not contain a DAE2 with ATA drives, and none of the following software is enabled on the storage system: SnapView, MirrorView, MirrorView/A, SAN Copy.

2

EMC CLARiiON Software Installation Guide

Storage-System and Server Requirements

CX500 or CX700 Storage-System Requirements The storage system is not part of a CLARiiON® Data Library or Celerra® configuration FLARE OE version 2.16 or higher is installed on the storage system or FLARE OE version 2.07 is installed on the storage system, the storage system does not contain a DAE2 with ATA drives, and none of the following software is enabled on the storage system: SnapView, MirrorView, MirrorView/A, SAN Copy software. Connected Server Requirements Failover software, such as PowerPath® software, must be running on each server. CLARalert® Remote Service software is not installed on the server.

Microsoft Windows 2000 servers could be susceptible to data loss during a LUN expansion operation unless Windows 2000 Service Pack 4 is installed. For this reason, we strongly recommend that you upgrade all Windows 2000 servers with Windows 2000 Service Pack 4 before you install FLARE OE software. For additional details on the Windows 2000 issue, see EMC Solution ID emc73538 and Microsoft Knowledge Base Article 327020.

EMC CLARiiON Software Installation Guide

3

Supported Software Installation Revisions

Supported Software Installation Revisions

You can install the software listed in Table 1 on a CX-Series storage system that meets the requirement listed in Storage-System and Server Requirements on page 2

Table 1

Software Revisions You Can Install Enablers

Storage System FLARE OE CX200 CX300 CX400 CX500 CX600 CX700

Access Logix

Navisphere Managera 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy

MirrorView N/A N/A 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy

MirrorView/A N/A N/A 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy

SAN Copy N/A N/A 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy

SnapView N/A 01.xx.yyy 01.01.yyy 01.01.yyy 01.01.yyy 01.01.yyy

Analyzer 01.xx.yyy 01.xx.yyy 01.xx.yyy 01.xx.yyy 01.xx.yyy 01.xx.yyy

02.16.200.5.yyy 01.01.yyy 02.16.300.5.yyy 01.01.yyy 02.16.400.5.yyy 01.01.yyy 02.16.500.5.yyy 01.01.yyy 02.16.600.5.yyy 01.01.yyy 02.16.700.5.yyy 01.01.yyy

a. Manage and Manager Base use the same enabler.

All CX-Series storage systems ship from the factory with a version of FLARE OE installed. Some CX-Series storage systems ship from the factory with some enablers installed, as listed in Table 2.

Table 2

Enablers for CX-Series Storage Systems

Enablers Installed on Storage System Prior to Shipment from Factory Storage System Access Logix Manager MirrorView MirrorView/A SAN Copy SnapView CX200 CX300 CX400 CX500 CX600 CX700 No Yes No Yes No Yes No Yes No Yes No Yes N/A N/A No No No No N/A N/A No No No No N/A N/A No No No No N/A No No No No No

Analyzer No No No No No No

4

EMC CLARiiON Software Installation Guide

Supported Software Installation Revisions

If you upgrade the FLARE OE on a storage system with any enablers installed, you do not need to reinstall the enablers. The MirrorView, MirrorView/A, SAN Copy, and SnapView enablers require that the Access Logix and Manager enablers are installed. You should install the Access Logix and Manager enablers at the same time that you install the MirrorView, MirrorView/A, SAN Copy, and/or SnapView enablers. The Analyzer enabler requires that the Manager enabler is installed. You can install the Manager and Analyzer enablers at the same time.

When to Upgrade from Manager Base to Manager

You must upgrade to EMC Navisphere Manager, if you want to do any of the following tasks with CX200 storage systems:

Manage other storage systems, including CX-Series, FC4700-Series, and legacy systems Manage storage systems remotely (from another subnet) Manage multiple CX200 storage systems Use centralized user account management with multiple CX200 storage systems Manage CX200 storage systems with HP OpenViewTM, Tivoli® Netview®, and CA-Unicenter® TNG software Monitor storage-system performance with Navisphere Analyzer

EMC CLARiiON Software Installation Guide

5

CX-Series Software Media

CX-Series Software Media

The CDs that ship that with FLARE OE upgrade and the Manager, Manager Base, Access Logix, MirrorView, MirrorView/A, SAN Copy, and SnapView, and Analyzer kits, along with the files you will need on these CDs are listed in Table 3. The FLARE OE upgrade CDs also contain a standalone version of the Software Installation Wizard.

Table 3

CX-Series Software Media Files Files You Need to Know About on CDb File to Install FLARE OE CX200-02.16.200.5.yyy.lst File to Start the Software Installation Wizard index.html Installed On Storage system

CD Title and Part Numbera

EMC CX200 FLARE OE Upgrade Version 02.16.200.5.yyy FLARE OE P/N 053-001-354

On host on same LAN as storage-system management port Storage system

EMC CX300 FLARE OE Upgrade Version 02.16.300.5.yyy FLARE OE P/N 053-001-351

File to Install FLARE OE CX300-02.16.200.5.yyy.lst File to Start the Software Installation Wizard iindex.html

On host on same LAN as storage-system management port Storage system

EMC CX400 FLARE OE Upgrade Version 02.16.400.5.yyy FLARE OE P/N 053-001-353

File to Install FLARE OE CX400-02.16.200.5.yyy.lst File to Start the Software Installation Wizard index.html

On host on same LAN as storage-system management port Storage system

EMC CX500 FLARE OE Upgrade Version 02.16.500.5.yyy FLARE OE P/N 053-001-350

File to Install FLARE OE CX500-02.16.500.5.yyy.lst File to Start the Software Installation Wizard index.html

On host on same LAN as storage-system management port Storage system

EMC CX600 FLARE OE Upgrade Version 02.16.600.5.yyy FLARE OE P/N 053-001-352

File to Install FLARE OE CX600-02.16.200.5.yyy.lst File to Start the Software Installation Wizard index.html

On host on same LAN as storage-system management port Storage system

EMC CX700 FLARE OE Upgrade Version 02.16.700.5.yyy FLARE OE P/N 053-001-349

File to Install FLARE OE CX700-02.16.500.5.yyy.lst File to Start the Software Installation Wizard index.html

On host on same LAN as storage-system management port

a. In the CD titles, x and y are numbers that vary with the specific version you have. b. In the filenames, w, x, y, and z are numbers that vary depending on your version.

6

EMC CLARiiON Software Installation Guide

CX-Series Software Media

Table 3

CX-Series Software Media Files (continued) Important Files on the CDb Enabler File AccessLogixEnabler-01.xx.5.yyy.ena Enabler File NavisphereManagerEnabler_01.xx.5.yyy.ena exe Files for Optional Window Hostc · Windows_ManagementServer_6.w.x.y.z.exe · Windows_UIs_6.w.x.y.z.exe Note: These executables are optional and should be installed only if you have storage systems without the Storage Management Server software installed and you want to manage these systems using Navisphere Manager. Files installed as part of the Windows server installation are protected by ACLs (under NTFS). ACLs are not supported on FAT file systems, so the files that normally would be protected under NTFS are not protected. Installed On Storage system

CD Title and Part Numbera

Access Logix Enabler v01.xx PN 053-001-160 Navisphere Manager Enabler v01.xx.5.yyy PN 053-001-224 Navisphere Manager Accessories v02.xx P/N 053-001-223

Storage system

Microsoft Windows ServerTM 2003, Windows® 2000, or Windows XP server Important: The executable files require a Java plug-in, which you can install on the server prior to launching Manager for the first time or when the application prompts you to install it. For a list of supported Java plug-ins, refer to the Manager Release Notes.

MirrorView Enabler v01.xx.5.yyy PN 053-001-224 MirrorView/A Enabler v01.xx.5.yyy PN 053-001-229 EMC SAN Copy Enabler v01.xx P/N 053-001-219 EMC SnapView Enable v01.xx P/N 300-001-221

Enabler File MirrorViewEnabler_01.xx.5.yyy.ena Enabler File MVAEnabler_01.xx.5.yyy.ena Enabler File SANCopyEnabler-01.xx.5.yyy.ena Enabler File SnapViewEnabler-01.xx.5.yyy.ena

Storage system

Storage system

Storage system

Storage system

a. In the CD titles, x and y are numbers that vary with the specific version you have. b. In the filenames, w, x, y, and z are numbers that vary depending on your version. c. You should install these files only if you want to use a Windows PC or server as a portal.

EMC CLARiiON Software Installation Guide

7

CX-Series Software Media

Table 3

CX-Series Software Media Files (continued) Files You Need on the CDb Enabler File AnalyzerEnabler_01.xx.5.yyy.ena .exe File for Optional Windows Hostc · Windows_AnalyzerProvider_6.w.x.y.z.exe Note: This executable is optional and should be installed only if · You have storage systems without the Storage Management Server software installed. · You want to manage these systems using Navisphere Manager. · You want to analyze the performance of these storage systems with Analyzer. This file also requires that the following files from the Navisphere Manager Accessories v02.xx CD (P/N 053-001-223) be installed on the host: · Windows_ManagementServer_6.w.x.y.z.exe · Windows_UIs_6.w.x.y.z.exe Files installed as part of the Windows server installation are protected by ACLs (under NTFS). ACLs are not supported on FAT file systems, so the files that normally would be protected under NTFS are not protected. Installed On Storage system

CD Title and Part Numbera

EMC Analyzer Enabler v01.xx.5.yyy PN 053-001-226 EMC Navisphere Analyzer Accessories v02.xx P/N 053-001-227

Microsoft Windows ServerTM 2003, Windows® 2000, or Windows XP server

a. In the CD titles, x and y are numbers that vary with the specific version you have. b. In the filenames, w, x, y, and z are numbers that vary depending on your version. c. You should install these files only if you want to use a Windows PC or server as a portal.

8

EMC CLARiiON Software Installation Guide

CX-Series Software Media

The FLARE OE upgrade software is also available on the EMC Powerlink website: http://powerlink.emc.com/support/sw_downloads/. The .zip files listed in Table 4 contain the FLARE OE software and a standalone version of the Software Installation Wizard. The enabler files are not available on this website.

Table 4

FLARE OE .zip Files File in .zip File to Install FLARE OE CX200--02.16.200.5.yyy.lst CX200--02.16.300.5.yyy.lst CX200--02.16.400.5.yyy.lst CX200--02.16.500.5.yyy.lst CX200--02.16.600.5.yyy.lst CX200--02.16.700.5.yyy.lst File in .zip File to Start Wizard index.html index.html index.html index.html index.html index.html

Storage System CX200 CX300 CX400 CX500 CX600 CX700

FLARE OE .zip File CX200-Bundle-02.16.200.5.yyy CX300-Bundle-02.16.300.5.yyy CX400-Bundle-02.16.400.5.yyy CX500-Bundle-02.16.500.5.yyy CX600-Bundle-02.16.600.5.yyy CX700-Bundle-02.16.700.5.yyy

EMC CLARiiON Software Installation Guide

9

Configuration Prerequisites

Configuration Prerequisites

This section describes the configuration requirements for using the following software:

MirrorView and MirrorView/A SnapView

MirrorView and MirrorView/A Configuration Requirements

MirrorView and MirrorView/A require the following:

One server, connected to one of the storage systems (a second server, connected to the other storage system, is optional). Both storage systems must be in the same Navisphere domain. A Fibre Channel connection between the two storage systems (direct, switch, or IP connection, shown on the following pages)

Cable Connections Between SPs at the MirrorView or MirrorView/A Sites MirrorView or MirrorView/A use a front-end port on each storage processor (SP) as a communication channel between the storage systems in a remote mirror configuration. This port is called the mirror port in this document. The mirror ports for the different storage systems are

Port 3 for a CX600 or CX700 SP Port 1 for a CX400 or CX500 SP

Although MirrorView and MirrorView/A can use the same SP ports, for performance reasons, we strongly recommend that they do not use the same SP ports.

!

CAUTION Currently, MirrorView and SAN Copy software cannot share the same SP port. Before installing the MirrorView Enabler, you must deselect any MirrorView ports that a SAN Copy session is using. Otherwise, any SAN Copy sessions using the MirrorView port will fail.

10

EMC CLARiiON Software Installation Guide

Configuration Prerequisites

For MirrorView or MirrorView/A to work correctly, the SP A mirror port at one site must be connected to the SP A mirror port on the other site and the SP B mirror port at one site must be connected to the SP B mirror port at the other site. The connections can be either direct or through a switch fabric. Either type of connection can be Fibre Channel (FC) or Fibre Channel over IP using FC-to-IP devices. Direct Remote Mirror Connections A direct mirror configuration consists of one primary storage system and one secondary storage system. The remote mirror connections must be between

SP A mirror ports on the primary and secondary storage systems SP B mirror ports on the primary and secondary storage systems

Figure 1 shows a sample direct remote mirror configuration.

Server H B A H B A Server H B A H B A

Dedicated Point-to-Point Connection

Optional Extenders 0 1 2 3 0 1 2 3 0 SP A 1 0 SP B 1

SP A

SP B

Primary Storage System CX600 or CX700

Figure 1

Secondary Storage System CX400 or CX500

EMC2226a

Sample Direct Remote Mirror Configuration

EMC CLARiiON Software Installation Guide

11

Configuration Prerequisites

Fabric Remote Mirror Connections A fabric mirror configuration consists of one primary storage system and up to four secondary storage systems. The fabric connections must be as follows:

SP A mirror port on the primary storage system must be connected to the same switch fabric as the SP A mirror port on the secondary storage system. SP B mirror port on the primary storage system must be connected to the same switch fabric as the SP B mirror port on the secondary storage system.

The fabric to which SP A mirror ports are connected can be the same fabric or a different fabric than the one to which the SP B mirror ports are connected.

You must zone the mirror port switch connections as follows:

A separate zone for the SP A mirror port on the primary storage system and the SP A mirror port on each secondary storage system. A separate zone for the SP B mirror port on the primary storage system and the SP B mirror port on each secondary storage system.

For example, if you have primary storage system 1 and secondary storage systems 2 and 3, you need the following two zones:

Zone 1 - SP A mirror port on storage system 1 and SP A mirror ports on storage systems 2 and 3. Zone 2 - SP B mirror port on storage system 1 and SP B mirror ports on storage systems 2 and 3.

Mirror ports can also receive host (server) I/O. If you want to use a mirror port for host I/O you will need a separate zone for each server HBA port and each mirror port with which you want the server to communicate. Figure 2 shows a sample remote mirror fabric configuration.

12

EMC CLARiiON Software Installation Guide

Configuration Prerequisites

Server H B A H B A

Server H B A H B A

Server H B A H B A

Server H B A H B A

Fabric Optional Extenders

Fabric

0

1

2

3

0

1

2

3

0 SP A

1

0 SP B

1

SP A

SP B

Primary Storage System CX600 or CX700 Zone 1 Zone 2

Figure 2

Secondary Storage System CX400 or CX500

EMC2227a

Sample Remote Mirror Connection Through a Fabric

SnapView Configuration Requirements

SnapView requires two servers, each connected to the storage system.

SAN Copy Configuration Requirements

SAN Copy has zoning requirements for the storage systems involved in SAN Copy sessions. These requirements are detailed in the SAN Copy administrator's guide and SAN Copy CLI reference. For information of finding these documents, refer to Finding Current Information on page 24.

EMC CLARiiON Software Installation Guide

13

Installing Software on a CX-Series Storage System

Installing Software on a CX-Series Storage System

The Software Installation Wizard that you use to install software on a storage system is available as part of Navisphere Manager or Navisphere Manager Base version 6.16 or higher user interface or as a standalone version. The standalone version is

On the FLARE OE bundle, version 02.16 or higher, CD in the FLARE OE upgrade kits In the FLARE OE version 02.16 .zip file on the Software Downloads section of the EMC Powerlink website: http://powerlink.emc.com/support/sw_downloads/

EMC recommends that you use the standalone version because it may contain newer features than the version in Navisphere Manager or Navisphere Manager Base. You can run the standalone version in an Internet Explorer, Netscape, of Mozilla browser. For the supported versions of these browsers, refer to the Navisphere Manager release note in the Release Notes section of the Document Library on the EMC Powerlink website. The steps you must follow to install storage-system software are

Checking the storage-system configuration Loading the software files that you want to install and the standalone Software Installation Wizard files, if you are using it, on the host from which you will run the wizard. Using the wizard to install the storage-system software.

To Check the Storage-System Configuration

For the installation of software on a storage system to succeed, the conditions (rules) in Table 5 must be met. The Software Installation Wizard will check that these rules are met. If any of them are not met and the wizard cannot fix the condition, the software is not installed. To ensure successful installation of the software, we strongly recommend that before starting the Software Installation Wizard, you verify that as many of these rules are met as you can.

14

EMC CLARiiON Software Installation Guide

Installing Software on a CX-Series Storage System

Table 5

Storage-System Configuration Checks Description The wizard is compatible with storage system software. Verifies that the wizard is compatible with storage system software. If this check fails, the wizard will not perform any other validation check. · All servers are running failover software · All servers have at least one working path to each storage processor (SP). · You have stopped I/O to all attached VMWare and AIX hosts. Storage processors (SPs) are available. For dual SP storage systems, where one SP is not operating normally, Navisphere displays an error icon and prevents the installation until the problem is fixed. If the storage system only has one SP, a warning icon is displayed. No LUNs are trespassed on the storage system. If LUNs are trespassed, a warning icon displays. No RAID Groups are expanding, no LUNs are binding or expanding, and no disks are equalizing or rebuilding on the storage system. No faults exist on the storage system. The only fault that is acceptable is a charging SPS. No ATA drives are installed on the storage system. If ATA drives are present, a service provider must perform the software installation. All packages installed on the storage system are committed. The wizard provides a fix if this rule is not met. No active SAN Copy, Incremental SAN Copy, or MirrorView/Asynchronous sessions are running. You must stop any sessions before performing the software installation. None of the enablers for the following applications are installed on the storage system: MirrorView, MirrorView/A, SAN Copy, SnapView, Analyzer. If the storage system is running the FLARE operating environment, version.02.07.x.y.z or earlier, and any of these enablers are installed, a service provider must perform the software installation. The SP utilization must be less than or equal to the maximum of 50%. If this rule fails, you must wait until the storage system is not as busy before starting the installation.

Rule Version Compatibility Special Conditions Warning

Redundant SPs

No Trespassed LUNs No Transitions No System Faults No ATA Drives All Packages Committed No Active Sessions No Layered Applications

Acceptable Processor Utilization

EMC CLARiiON Software Installation Guide

15

Installing Software on a CX-Series Storage System

To Load the Storage-System Software and Wizard on the Server

1. On the host with the browser that you will use to run the standalone Software Installation Wizard or Navisphere Manager, create a directory (referred to as the installation directory) for the software the storage-system. 2. If you are using the FLARE OE upgrade CD: a. Insert the upgrade CD into a CD drive on the host with the installation directory. b. Copy the contents of the upgrade CD to the installation directory. 3. If you are using a FLARE OE .zip file from the EMC Powerlink website (http://powerlink.emc.com/support/sw_downloads/): a. Download the CXxxx-Bundle-02.16.xxx.5.yyy.zip file from the Software Downloads section of this site to the installation directory. The .zip files contains both the FLARE OE and Software Installation Wizard files. b. Unzip the CXxxx-Bundle-02.16.xxx.5.yyy.zip file to the installation directory. 4. If you are installing a new enabler:

If an enabler is already installed, you do not need to re-install it, even if you are installing a new version of FLARE OE.

a. Locate the appropriate enabler CDs. For a list of the enabler CDs, refer to Table 3 on page 6. b. Copy the enabler (.ena) file for each new enabler that you want to install from the enabler CD to the installation directory. For a list of the enabler files, refer to Table 3 on page 6.

16

EMC CLARiiON Software Installation Guide

Installing Software on a CX-Series Storage System

To Use the Software Installation Wizard

WARNING Under no circumstances, pull an SP out while the software installation is in progress. Doing so could permanently disable the SP and cause it to be unusable. 1. Start either the standalone or Manager version of the Software Installation Wizard: To start the standalone version a. In the installation directory on the host, double-click the index.html file. b. Enter the IP address of an SP in the storage system. c. Enter the user and password for the storage system. To start the Manager version a. Open a browser and enter the IP address of an SP in the storage system that has Navisphere 6.X installed, preferably the most current version. b. Right-click the storage-system icon on which you want to install the software and click Software Operations > Software Installation Wizard.

The Wizard lets you install software on only one storage system at a time. Do not select multiple storage systems.

2. Follow the wizard screens, using the Wizard online help, if necessary, to install any desired software (FLARE OE and/or enablers) being sure to select all the software (.lst file and/or .ena files) that you want to install.

SnapView sessions running in persistence mode will continue to run while the Software Installation Wizard is installing software.

3. When the installation is complete, close the wizard.

EMC CLARiiON Software Installation Guide

17

Installing Software on a CX-Series Storage System

If an open browser is pointing to the storage system to which you downloaded the software, you must close that browser and open a new one in order to view the new UI content. Clear the browser cache and the JRE cache.

To Re-enable Statistics Logging

The Software Installation Wizard disables statistics logging. After the installation is complete, you should re-enable it. 1. Start Navisphere Manager: a. From a host on the same LAN as the storage system, open a browser. b. Enter the IP address of an SP in the storage system. c. Log in to Navisphere Manager by entering your username and password. 2. In the Enterprise Storage dialog box, right-click the icon for the storage system and click Properties. 3. In the General tab, under Configuration, select Statistics Logging. This turns statistics logging on for any SPs in the storage system.

Click Help in the dialog box to display descriptions of each property in the dialog box.

To Commit (Finalizing) the Newly Installed Software

New features in the software you installed are not available until you commit the software. When you are ready to use the software in a production environment, you must commit the software to finalize the installation. The write cache is flushed as part of the commit operation. This can be a time consuming operation, and Navisphere Manager may time out waiting for a response from the storage system. If this happens, Navisphere Manager displays one or both SPs as unmanaged. However, even though the SPs are unmanaged, they are still

18

EMC CLARiiON Software Installation Guide

Installing Software on a CX-Series Storage System

servicing I/O in this state. Once the commit is complete, Manager displays the state of the SPs as normal.

!

CAUTION You cannot create any new RAID Groups, or bind any new LUNs until you commit the FLARE Operating Environment software package. New features are not available until the commit is competed. Once you commit a software package, you cannot revert it (return to the previous version).

To Commit Software

1. Start Navisphere Manager: a. Open a browser on the any host on the same LAN as the management port of a storage system with Navisphere Manager 6.x installed. b. Enter the IP address of an SP in the storage system. c. Log in to Navisphere Manager by entering your username and password. 2. In the Enterprise Storage dialog box, right-click the icon for the storage system with the software package you want to commit, and then click Properties. 3. Click the Software tab. 4. Select the software package that you want to commit, and click Commit. These packages have an Active (commit required) status.

Click Help in the dialog box to display descriptions of each property in the dialog box.

EMC CLARiiON Software Installation Guide

19

Installing and Uninstalling .exe Files on a Windows Server

Installing and Uninstalling .exe Files on a Windows Server

Installing the .exe files on a Windows server is optional.

If you want to use a Windows PC or server as a portal in your Navisphere domain, you must install the Windows Management Server and Windows UI executables on the portal. These executables are provided on the Navisphere Manager Accessories CD (see Table 3 on page 6). To install these executables, follow the instructions in the InstallShield Wizard and select the Manager UI, and the UIs for any other software installed on storage systems in the same domain as the Windows server.

You can also use these executables on a Windows host to provide additional security for interactions between the browser and the storage system, over and above the security provided by Navisphere Manager. For more information, refer to the network configurations information in the EMC Navisphere Security Administrator's Guide (P/N 069001124).

Specifying Communication Ports and Initializing Security

You must specify the server communication ports for the Windows server on which you installed the Navisphere UIs and Management Server executables. EMC strongly recommends that you also initialize security for this server. To Specify the Server Communication Ports 1. From the server where you installed the Navisphere UIs and Management Server executables, open a new Internet browser window and enter the appropriate url as shown below. · If a web server such as IIS is running on the server, there is a conflict with using standard ports to access Navisphere Manager. You must specify the Navisphere defined ports by entering the following url: http://localhost:2162/setup · If you do not have a web server running, enter the following url: http://localhost/setup

20

EMC CLARiiON Software Installation Guide

Installing and Uninstalling .exe Files on a Windows Server

The Management Server Networking Configuration dialog box opens. 2. Verify the following: · IP to listen on lists the IP address(es) of the server.

If you have multiple LAN cards or ports, select one of the IP addresses from the pull-down menu or use the default IP address.

· Management Ports lists the ports of the server that are available for communication. 3. Click Apply Settings.

You must click Apply Settings for the Management Server to recognize the IP address.

To Initialize Security for the Server 1. From the Internet browser window, type the IP address of the server (the same IP address listed in the IP to listen on from step 2 of the Management Server Settings section). The Confirm: Navisphere Security dialog box opens.

You may see a screen indicating that you must download the Java plug-in. Once you have downloaded this plug-in, install it on the server and repeat step 1.

2. Click Yes to set the security. The Create Global Administrator dialog box opens. 3. Type a username and password. Click OK. 4. Click Yes in the Confirm:Add User? dialog box to add the new user. 5. Click OK in the Success: Initialize Security dialog box. 6. From Navisphere, log in as the Global Administrator (File > Login).

EMC CLARiiON Software Installation Guide

21

Installing and Uninstalling .exe Files on a Windows Server

To Use the Windows Server Once you have installed the Navisphere UIs and Management Server executables on the Windows server, specified the communication ports for this server, and initialized security, you can configure this server as a portal. A portal lets you manage storage systems that do not have the Storage Management Server software installed (legacy storage systems), and it lets you centrally monitor storage-system events via a Host Agent. For example, use this server as a portal when

you do not have a storage system with Storage Management Server software installed that can be used as a portal, and you want to manage legacy storage systems and centrally monitor storage system events, or you do have a storage system with Storage Management Server software installed, but you do not want to use this storage system as the portal.

When uninstalling the Navisphere UIs and Management Server executables from the Windows server (portal), you must first remove the node from any domain in which it is participating. If the software is reinstalled later on the same server, you can add the node back into the domain.

What Next?

For information on adding this server to an existing domain and setting up security see the EMC Navisphere Security Administrator's Guide (P/N 069001124). If you want to use this server to manage legacy storage systems and NAS systems, refer to the EMC Navisphere Manager Administrator's Guide (P/N 069001125).

22

EMC CLARiiON Software Installation Guide

Adding a CX200 Storage System to a Domain

Adding a CX200 Storage System to a Domain

If you upgrade from Manager Base to Manager, you can add the upgraded CX200 storage system to a new or existing domain. 1. In a web browser, enter the IP address for SP A's setup page. For example, if the IP address for SP A is 10.11.12.13, enter http://10.11.12.13/setup in the web browser. This opens the setup page for SP A. 2. In SP A's setup page, click Destroy Security and Domain Information. 3. Select Yes to confirm the reset operation, and then select Submit. This removes all previously configured users and destroys the domain. 4. For a dual-SP CX200, repeat all steps for SP B.

EMC CLARiiON Software Installation Guide

23

Using Enabled Software

Using Enabled Software

For information on using enabled software, refer to one of the following documents for the software:

Administrator's guide - describes the graphical user interface for the software, which is integrated into Navisphere Manager. Command line interface (CLI) reference - a reference of the commands for using the software

Access Logix is the software that provides the Storage Group functionality for connecting multiple servers to a storage system. Unlike the other enabled software, Access Logix does not have it own administrator's guide. Instead, its use is covered in the Navisphere Manager Administrator's Guide and the Navisphere CLI Reference.

The administrator's guides and CLI references are in the Document Library on the Support section of the EMC Powerlink website and on the EMC CX-Series Hardware and Software Documentation CD that ships with CX-Series storage systems. For information on accessing Powerlink, go to the next section, Finding Current Information.

Finding Current Information

Documents on using the CX-Series software are available on the EMC CX-Series Hardware and Software Documentation CD that ships with CX-Series storage systems. The most up-to-date versions of these documents and other information about CX-Series software, including software release notes, are posted on the EMC Powerlink website. We recommend that you download the latest information before you use the software. If you purchased this product from an EMC reseller and you cannot access Powerlink, the latest product information should be available from your reseller. Information on Installing CLARiiON Server Software Refer to the CX-Series Server Software Installation Guide for your operating system on the Powerlink website or on the EMC CX-Series Hardware and Software Documentation CD.

24

EMC CLARiiON Software Installation Guide

Finding Current Information

Information on Installing FC4700 Software Refer to the entry listed below for the appropriate document on the EMC Powerlink website.

Software Access Logix Navisphere Manager MirrorView (synchronous) SAN Copy SnapView Analyzer Document on Powerlink Access Logix for CX-Series Storage Systems Installation Guide Navisphere Manager Installation Guide EMC MirrorView Installation Guide SAN Copy Installation Guide SnapView Installation Guide Navisphere Analyzer 6.X Installation Guide Document Entry FLARE 02.07.xxx.5.yyy Version 6.6.0 Version 1.70.0x Version 2.0 Version 2.3 Version 6.6.0

To access documents on Powerlink Use the following link: http://powerlink.emc.com After you log in, select Support > Document Library. You can view these documents with a PDF viewer, such as the latest version of Adobe Acrobat Reader. You can download a free copy of this reader from http://www.adobe.com/products/acrobat/.

EMC CLARiiON Software Installation Guide

25

Finding Current Information

Copyright © 2004-2005 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.

Trademark Information

EMC2, EMC, CLARalert, CLARiiON, Navisphere, and PowerPath are registered trademarks and Access Logix, FLARE, MirrorView, SAN Copy, and SnapView are trademarks of EMC Corporation. All other trademarks mentioned herein are the property of their respective owners.

26

EMC CLARiiON Software Installation Guide

Information

EMC CLARiiON Software Installation Guide

26 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate