Read NEMA-HP4-TYPE-K.pdf text version

NEMA HP-4 Type K

For internal wiring of meters, panels and electronic equipment . Formerly "Mil-W-16878/11."

Extruded PTFE Insulation Silver Plated Copper Stranded

Electronic Hookup Wire

· Exruded Polytetrafluoroethylene (PTFE) Insulation · Nominal .010" Wall · -65ºC to +200ºC · 600 Volts. R.M.S. (working)

Meets UL Style 1226, 1227, 1371, 1538 80ºC & 105º except where noted.

Military Voltage Rating Dielectric Voltage Withstand Sine-wave Spark-Test Voltage Impulse Spark Test Voltage Insulation Breakdown Voltage IR: Insulation Resistance, wet Nominal Dielectric Constant value Flame Properties Fungus

600 volts. 2000 Volts 4600 VAC. 6500 V pulse-peak, or 5700 V @3 kHz > 7000 volts, peak. > 30000 megohm/100 mtr, metal to water bath at +20oC 2.06 Self extinguishing. Meets UL VW-1 Fungus resistant

GAUGE (AWG)

PART NO.

NEMA HP-4 SPEC NEMA PART NO.

GAUGE OF STRANDS (AWG)

GAUGE OF STRANDS (AWG

NOM. DIAM. OF STRANDED CONDUCTOR IN. mm

NOM. FIN. WIRE DIAM. IN. mm

MAX. RESISTANCE (dc at 20º C) /per 1000-ft Km

NOM. WT. LBS per 1000-ft Kg/Km

32 32 30 30 28 28 26 26 26 24 24 24 22 22 22 20 20 20 18 18 18 16 16 14 14 12 10

NK132U NK740U NK130U NK738U NK128U NK736U NK126U NK734U NK1938U NK124U NK732U NK1936U NK122U NK730U NK1934U NK120U NK728U NK1932U NK118U NK726U NK1930U NK116U NK1929U NK114U NK1927U NK1925U NK3726U

HP4-K-BAAx HP4-K-BABx HP4-K-BBAx HP4-K-BBBx HP4-K-BCAx HP4-K-BCBx HP4-K-BDAx HP4-K-BDBx HP4-K-BDEx HP4-K-EABx HP4-K-BEBx HP4-K-BEEx HP4-K-BFAx HP4-K-BFBx HP4-K-BFEx HP4-K-BGAx HP4-K-BGBx HP4-K-BGEx HP4-K-BHAx HP4-K-BHBx HP4-K-BHEx HP4-K-BJAx HP4-K-BJEx HP4-K-BKAx HP4-K-BKEx HP4-K-BLEx HP4-K-BMGx

1 7 1 7 1 7 1 7 19 1 7 19 1 7 19 1 7 19 1 7 19 1 19 1 19 19 37

32 40 30 38 28 36 26 34 38 24 32 36 22 30 34 20 28 32 18 26 30 16 29 14 27 25 26

.0089 .0100 .0100 .0120 .0126 .0150 .0159 .0190 .0200 .0201 .0240 .0250 .0254 .0300 .0320 .0320 .0380 .0400 .0403 .480 .0500 .0508 .0570 .0641 .0720 .0910 .1110

.226 .254 .254 .305 .320 .381 .404 .483 .508 .511 .610 .635 .654 .762 .813 .813 .965 1.02 1.02 1.22 1.27 1.29 1.45 1.63 1.83 2.31 2.82

.028 .030 .030 .032 .033 .035 .036 .039 .039 .040 .044 .044 .045 .050 .050 .052 .058 .058 .061 .069 .069 .079 .080 .087 .095 .114 .134

.711 .762 .762 .813 .838 .889 .914 .991 .991 1.02 1.12 1.12 1.14 1.27 1.27 1.32 1.47 1.47 1.55 1.75 1.75 1.88 2.03 2.21 2.41 2.91 3.40

169.000 173.000 108.000 100.700 68.000 63.800 42.700 40.500 38.400 26.800 25.200 24.300 17.000 15.900 15.100 10.500 10.000 9.190 6.600 6.280 5.790 4.200 4.520 2.580 2.880 1.810 1.190

555 568 354 330 223 209 140 133 126 88 83 80 56 52 50 35 33 30 22 21 19 14 15 9 9 6 4

.92 .96 1.10 1.20 1.40 1.50 1.80 2.00 2.10 2.50 2.70 2.80 3.40 3.70 3.80 4.80 5.30 5.60 7.00 7.90 8.30 10.54 11.00 14.40 16.00 24.10 35.20

1.37 1.43 1.64 1.79 2.08 2.23 2.68 2.98 3.13 3.72 4.02 4.17 5.06 5.51 5.65 7.14 7.89 8.33 10.4 11.8 12.4 15.6 16.4 21.4 23.8 35.9 52.4

Standard basic insulation color numbers are: Black: 0, Brown: 1, Red: 2, Orange: 3, Yellow: 4, Green: 5, Blue: 6, Violet: 7, Gray: 8, White: 9. The insulation color code number, per MIL-STD-681, may be 1, 2 or 3 digits depending on the number or absence of stripes. The 1st number is color of Insulation, 2nd number is color of first stripe; 3rd number is color of the second stripe. Example: White wire(9) + Red stripe(2) + Black stripe(0) makes a color code number of "920". That color number, "920" is appended to the part number. Sample part number might be "xxxxxx-xxx-920" Not U.L. Recognized

1-19

NATIONAL WIRE & CABLE custom cable manufacturing & molding · www.nationalwire.com

Order Desk 323-225-5611

Information