Read Eaton_MEM_MCCB_Panelboard_Distribution_System_Technical.pdf text version

MCCB Panelboard Distribution System

Product Focus

2005 Catalogue

Features and Benefits

G

250A, 400A, 630A & 800A panelboard versions available. 3 to 18 outgoing ways. Outgoing MCCBs up to 400A. KEMA certified. IP3X construction. Form 3B segregation (with terminal shields fitted). Tin - plated busbar systems throughout the range. Transient voltage surge (TVSS ) protection.

G

Metering options. Reliable & safe operation assured through KEMA testing & certification. Optional side extension modules provide improved access for larger cables. Versatile solution, accommodating different size outgoing MCCBs to best match application needs. Enhanced safety through fully shrouded incoming devices, to protect against contact with live parts. Blanking plates finger protect unused outgoing ways.

G G

G

G

G

G

G

G

G

G

G

G

Contents

Panelboard Selection Factory Built Assemblies Panelboards up to 400A Panelboards 400A to 630A

Page

2 3 4 6 Panelboards 800A TVSS Dimensions Circuit BreakerTechnical Data 8 10 11 12

2

3

1

4

5

1 2

Lift off hinged door. Form 3B segregation (with terminal shields fitted). Removable top and bottom gland plates.

4 5

RAL 7004 epoxy polyester finish. Neutral and earth arrangements: G Split neutral & earth. G Additional terminal capacity provided for multiple single pole MCCB outgoers.

3

1

Panelboard Selection

Type 1 Panelboard ­ 125A Busbar

Incoming device; 125A horizontally mounted G Outgoing devices; 3 x 16 ­ 125A TP or 9 SP MCCBs See page 4

G

Type 4 Panelboard ­ 400A Busbar

Incoming device; 250A ­ 400A G Direct connection lugs G Outgoing devices; up to 2 x 63A ­ 250A TP MCCBs + up to 16 x 16A - 125A TP or 54 SP MCCBs See page 6

G

Type 2 Panelboard ­ 250A Busbar

Incoming device; 160A ­ 250A G Outgoing devices; up to 12 x 16A ­ 125A TP or 36 SP MCCBs See page 4

G

Type 5 Panelboard ­ 630A Busbar

Incoming device; 400A ­ 630A G Direct connection lugs G Outgoing devices; up to 4 x 63A ­ 250A TP MCCBs + up to 14 x 16A 125A TP or 42 SP MCCBs See page 6

G

Type 3 Panelboard ­ 400A Busbar

G

Type 6 Panelboard ­ 800A Busbar

G G G

Incoming device; 250A ­ 400A Direct connection lugs Outgoing devices; up to 12 x 16A ­ 125A TP or 36 SP MCCBs

Incoming device; 800A Direct connection lugs Outgoing devices; up to 2 x 250A ­ 400A TP MCCBs +up to 4 x 63A ­ 250A TP MCCBs + up to 6 x 16A ­ 125A TP or 18 SP MCCBs

G

G

See page 4

See page 8

2

Options and Accessories

Choice of MCCB, circuit breaker switch or direct connection incomer.

Side cable boxes and top / bottom cable extension boxes.

Analogue and digital meter packs.

Door locking option.

Factory Built Assemblies

Complete factory built assemblies can be specified for individual projects, on which the factory will be pleased to advise.

Simple derivatives include:G

The fitment of side extension boxes, dual incomers and metering options etc.

Through a modular Panelboard system, more custom solutions can be accommodated to include:G G

4 pole switching options. Fused combination switches for both incomers and outgoing ways. Form 4 type 2 solutions.

G

For more details on these services please contact our customer support team on 08700 545 333.

3

Type 1, 2 & 3 Panelboard Selection - 125A, 250A, and 400A Busbar

G G G G

IEC60439 ­ 1 Tin-plated busbars Outgoing devices; 16A ­ 125A TP & SP IP3X construction (Type 2 & 3)

G

Busbar system KEMA certified PBEG325 ­ 25kA Icc PBEG625/825/1225 ­ 40kA Icc PBEG640/1240 ­ 30kA Icw for 1s

1 - Panelboard

Description Type 1 ­ 125A Type 2 ­ 250A No of Ways 3 6 8 12 Type 3 ­ 400A 6 12 List No PBEG325 PBEG625 PBEG825 PBEG1225 PBEG640 PBEG1240 GL - Frame GJ - Frame Associated Incoming Device GE - Frame

2 - Incoming Device MCCB

Description 100A 18kA 125A 18kA 125A 25kA 160A 40kA 200A 40kA 250A 40kA 250A 50kA 320A 50kA 400A 50kA GE - Frame List No GEB3100FFG GEB3125FFG GEE3125FFG GJS3160AAG GJS3200AAG GJS3250AAG GLS3250AAM GLS3320AAM GLS3400AAM GJ - Frame List No GL - Frame List No

Circuit Breaker Switch Incomer

Description 100A 25kA 125A 25kA 160A 40kA 200A 40kA 250A 40kA 250A 50kA 320A 50kA 400A 50kA GE - Frame List No GEK3100KSG GEK3125KSG GJK3160KSG GJK3200KSG GJK3250KSG GLK3250KSM GLK3320KSM GLK3400KSM GJ - Frame List No GL - Frame List No

3 - Incomer Connection Kits

Description Type 1 Type 2 Type 3 Incomer GE - Frame GJ - Frame GJ - Frame GL - Frame GL - Frame Direct connection lugs kit Direct connection lugs kit

4

Connection Kit List No Not required Not required PBEGJG25M PBEGLG40 PBEGLG40M PBEGL40 PBEGL40M Metering version - includes CT`s* Metering version - includes CT`s* Incoming device must be used Incoming device must be used Metering version - includes CT`s*

* Meter pack must be ordered seperately.

4 - Outgoing Devices GE - Frame MCCBs

Frame size Current rating, (A) 16A 20A 32A 40A 50A 63A 80A 100A 125A 18kA TP List No GEB3016FFG GEB3020FFG GEB3032FFG GEB3040FFG GEB3050FFG GEB3063FFG GEB3080FFG GEB3100FFG GEB3125FFG SP List No GEB1016FFG GEB1020FFG GEB1032FFG GEB1040FFG GEB1050FFG GEB1063FFG GEB1080FFG GEB1100FFG GEB1125FFG 25kA TP List No GEE3016FFG GEE3020FFG GEE3032FFG GEE3040FFG GEE3050FFG GEE3063FFG GEE3080FFG GEE3100FFG GEE3125FFG SP List No GEE1016FFG GEE1020FFG GEE1032FFG GEE1040FFG GEE1050FFG GEE1063FFG GEE1080FFG GEE1100FFG GEE1125FFG

5 - Accessories

Description SP blanking module GE - Frame (1 pole per pack) Panel door lock with key MCCB accessory termination block for connection of shunt trips, UVR's, etc. List No PBEGB1 PBDLK2 PBTB1

PBEGB3

Extension Boxes

Side Cable Boxes Description To fit Panelboard PBEG625 To fit Panelboard PBEG640 & PBEG825 To fit Panelboard PBEG1225 To fit Panelboard PBEG1240 Top / Bottom Cable Extension Boxes Description 250mm high Corner Filler Box For use where top/ bottom / meter boxes are fitted in conjunction with side cable boxes PBEGSX250 List No PBEGEX250 List No PBEGSX900 PBEGSX1050 PBEGSX1150 PBEGSX1300

Meter Packs

Incoming connection kit: Metering version required Description Analogue Meter Packs Analogue voltmeter & selector switch. Analogue ammeter & selector switch. Phase indication lamps List No 6, 8, 12 way GJ - Frame incomer 6, 12 way GL - Frame incomer Digital Meter Packs kW/hr, phase Amps, phase Volts, line Volts, per phase PF, per phase kW, 3 phase PF, 3 phase kW, frequency, import kWh (ie; pulsed output) GJ/GL - Frame incomer PBEGMPD PBEGMPD PBEGMPA25 PBEGMPA40 List No 250A 400A

Meter packs include the meter and housing, cable loom and fuses. Where a meter pack is used with a GL incomer a cable extension box ; PBEGEX250, will also be required to provide additional space for incoming cables. This will need to be ordered separately.

5

Type 4 & 5 Panelboard Selection - 400A & 630A Busbar

G G G

IEC 60439 ­ 1 Tin-plated busbars Outgoing devices; these panelboards utilise two frame sizes of MCCB: 63A ­ 250A TP and 16A ­ 125A TP & SP

G G

IP3X construction Busbar system KEMA certified Type 4 ­ 35kA Icw for 1s Type 5 ­ 50kA Icw for 1s

1 - Panelboard

Description Type 4 ­ 400A No of Ways 6 (2 x 250A + 4 x 125A) 12 (2 x 250A + 10 x 125A) 18 (2 x 250A + 16 x 125A) Type 5 ­ 630A 8 (4 x 250A + 4 x 125A) 12 (4 x 250A + 8 x 125A) 18 (4 x 250A + 14 x 125A) List No PBJG640 PBJG1240 PBJG1840 PBJG863 PBJG1263 PBJG1863

2 - Incoming Device - Connection kit required MCCB

Description 250A 40kA 250A 50kA 320A 50kA 400A 50kA 400A 70kA 630A 50kA 630A 70kA 630A electronic LSI Type 4 List No GJS3250AAG GLS3250AAM GLS3320AAM GLS3400AAM GLH3400AAM GLS3250AAM GLS3320AAM GLS3400AAM GLH3400AAM GLS3630AAM GLH3630AAM GLH363032M Type 5 List No

Circuit Breaker Switch Incomer

Description 250A 40kA 250A 50kA 320A 50kA 400A 50kA 630A 50kA Type 4 List No GJK3250KSG GLK3250KSM GLK3320KSM GLK3400KSM GLK3250KSM GLK3320KSM GLK3400KSM GLK3630KSM Type 5 List No

3 - Incomer Connection Kits

Description Type 4 Incomer GJ Frame 250A GJ Frame 250A GL Frame 400A GL Frame 400A Lugs Connection 400A Lugs Connection 400A Type 5 GL Frame 630A GL Frame 630A Lugs Connection 630A Lugs Connection 630A * Meter pack must be ordered separately List No PBJGJG25 PBJGJG25M PBJGLG40 PBJGLG40M PBJGL40 PBJGL40M PBJGLG63 PBJGLG63M PBJGL63 PBJGL63M Metering version - includes CT`s* Metering version - includes CT`s* Metering version - includes CT`s* Metering version - includes CT`s* Metering version - includes CT`s*

4 - Outgoing Devices GJ - Frame MCCBs

Up to 2 for size 4 Panelboards, up to 4 for size 5 Panelboards Frame size Current rating, (A) 80A 100A 125A 160A 200A 250A

6

40kA TP List No GJS3080AAG GJS3100AAG GJS3125AAG GJS3160AAG GJS3200AAG GJS3250AAG

Outgoing Devices GE - Frame MCCBs

Frame size 18kA SP List No GEB1016FFG GEB1020FFG GEB1032FFG GEB1040FFG GEB1050FFG GEB1063FFG GEB1080FFG GEB1100FFG GEB1125FFG List No 16A 20A 32A 40A 50A 63A 80A 100A 125A GEB3016FFG GEB3020FFG GEB3032FFG GEB3040FFG GEB3050FFG GEB3063FFG GEB3080FFG GEB3100FFG GEB3125FFG 25kA TP List No GEE3016FFG GEE3020FFG GEE3032FFG GEE3040FFG GEE3050FFG GEE3063FFG GEE3080FFG GEE3100FFG GEE3125FFG SP List No GEE1016FFG GEE1020FFG GEE1032FFG GEE1040FFG GEE1050FFG GEE1063FFG GEE1080FFG GEE1100FFG GEE1125FFG Current rating, (A) TP

5 - Accessories

Description TP blanking module GJ - Frame Panel door lock with key MCCB accessory termination block for connection of shunt trips, UVR's, etc. PBJGB3 List No PBJGB3 PBDLK2 PBTB1

SP blanking module GE - Frame (1 pole per pack) PBEGB1

Extension Boxes

Side Cable Boxes Description To fit panelboard PBJG640 & PBJG863 To fit panelboard PBJG1240 & PBJG1263 To fit panelboard PBJG1840 & PBJG1863 Top / Bottom Cable Extension Boxes Description 250mm high Corner Filler Box For use where top / bottom / meter boxes are fitted in conjunction with side cable boxes PBSX250 List No PBEX250 List No PBJGSX1400 PBSX1600 PBSX1800

Meter Packs

Incoming connection kit: Metering version required Description Analogue Meter Packs Analogue voltmeter & selector switch. Analogue ammeter & selector switch. Phase indication lamps List No Type 4 Type 5 Digital Meter Packs kW/hr, phase Amps, phase Volts, line Volts, per phase PF, per phase kW, 3 phase PF, 3 phase kW, frequency, import kWh (ie; pulsed output) Type 4/5 PBJGMPD PBJGMPD PBJGMPD PBJGMPA25 List No PBJGMPA40 PBJGMPA63 List No 250A 400A 630A

Meter packs include the meter and housing, cable loom and fuses. Where a meter pack is used with a GL incomer a cable extension box; PBEX250, will also be required to provide additional space for incoming cables.

7

Type 6 Panelboard Selection - 800A Busbar

G G G

IEC 60439 ­ 1 Tin-plated busbars Outgoing devices; these panelboards utilise three frame sizes of MCCB: 250A ­ 400A TP 63A ­ 250A , TP 16A ­ 125A TP & SP ,

G G

IP3X construction Busbar system KEMA certified; 50kA Icw for 1s

1 - Panelboard

Description Type 6 ­ 800A No of Ways 8 (2 x 400A + 2 x 250A + 4 x 125A) List No PBLG880

12 (2 x 400A + 4 x 250A + 6 x 125A) PBLG1280

2 - Incoming Device - Connection kit required

MCCB / Circuit Breaker Switch Description 800A 50kA MCCB 800A 50kA CBS List No GLW3800T32W GLK3800KSW

3 - Incomer Connection Kits

Description Type 6 Incomer 800A MCCB or CBS Direct connection lugs kit 800A MCCB or CBS 800A Direct connection lugs kit List No PBLGLW80 PBJGL63 PBLGLW80M Metering version - includes CT`s PBJGL63M Metering version - includes CT`s

4 - Outgoing Devices GL - Frame MCCBs

Up to 2 per panelboard Side cable box (es) required when fitting GL MCCB (s). 630A Frame size Current rating, (A) 250A 320A 400A 50kA TP List No GLS3250AAG GLS3320AAG GLS3400AAG

Outgoing Devices GJ - Frame MCCBs

Up to 2 for PBLG880, up to 4 for PBLG1280 250A Frame size Current rating, (A) 80A 100A 125A 160A 200A 250A

8

40kA TP List No GJS3080AAG GJS3100AAG GJS3125AAG GJS3160AAG GJS3200AAG GJS3250AAG

Outgoing Devices GE - Frame MCCBs

125A Frame size 18kA SP List No GEB1016FFG GEB1020FFG GEB1032FFG GEB1040FFG GEB1050FFG GEB1063FFG GEB1080FFG GEB1100FFG GEB1125FFG List No 16A 20A 32A 40A 50A 63A 80A 100A 125A GEB3016FFG GEB3020FFG GEB3032FFG GEB3040FFG GEB3050FFG GEB3063FFG GEB3080FFG GEB3100FFG GEB3125FFG 25kA TP List No GEE3016FFG GEE3020FFG GEE3032FFG GEE3040FFG GEE3050FFG GEE3063FFG GEE3080FFG GEE3100FFG GEE3125FFG SP List No GEE1016FFG GEE1020FFG GEE1032FFG GEE1040FFG GEE1050FFG GEE1063FFG GEE1080FFG GEE1100FFG GEE1125FFG Current rating, (A) TP

5 - Accessories

Description SP blanking module GE - Frame (1 pole per pack) TP blanking module GJ - Frame TP blanking module GL - Frame Panel door lock with key MCCB accessory termination block for PBLGB3 connection of shunt trips, UVR's, etc. PBJGB3 PBLGB3 PBDLK2 PBTB1 List No PBEGB1

Extension Boxes

Side Cable Boxes Description 800A (2 + 2 + 4 way) 800A (2 + 4 + 6 way) Top / Bottom Extension Boxes Description 250mm high Corner Filler Box For use where top / bottom / meter boxes are fitted in conjunction with side cable boxes PBSX250 List No PBEX250 List No PBSX1600 PBSX1800

Meter Packs Meter Packs Incoming connection kit: Metering version required

Description Analogue Meter Packs Analogue voltmeter & selector switch. Analogue ammeter & selector switch. Phase indication lamps List No PBLGMPA63 Digital Meter Packs kW/hr, phase Amps, phase Volts, line Volts, per phase PF, per phase kW, 3 phase PF, 3 phase kW, frequency, import kWh (ie; pulsed output) List No PBJGMPD

Meter packs include the meter and housing, cable loom and fuses. Where a meter pack is used, a cable extension box; PBEX250, will also be required to provide additional space for incoming cables.

800A busbar

9

TVSS Kits for MCCB Panelboards

A Surge Protective Device has been developed specifically for application with MCCB panelboards ensuring outstanding product performance for all sensitive, mission critical and general purpose loads. The UL1449 Second Edition and UL1283 listed devices provide high peak surge current ratings and exceptionally low real-world measured limiting (letthrough) voltage values, together with outstanding durability, assuring a lifetime of effective, maintenance free protection for all electrical and electronic systems. Protection: Active Response Network (ARN) provides optimum suppression of internal switching generated transients. Threshold Response Network (TRN) provides maximum suppression of high energy impulse generated transients. This assures excellent protection of sensitive electronic, electro-mechanical and micro-processor based equipment. LED status indication is provided. Volt free relay allows remote status indication.

General Specifications: Description: Application: Warranty: Unit listings: Quality: Parallel configured, hard wire connected, 80kA per phase peak surge current Transient Voltage Surge Suppressor. Location Categories B and A, medium and low exposure level. General purpose, sensitive, and mission critical loads. Small AC power service entrances ( 630amps), MCCB panelboards. 10-Year Free Replacement. UL1449 Second Edition, UL1283 Filter. ISO 9001: 1994 Quality System Certification BSI FM 30833.

Mechanical Specifications: TVSS Enclosure: Mounting: Connection: Shipping weight: IP23 rated steel enclosure. Conduit fitting and multi-point mounting feet. Standard products include approx. 450mm factory fitted stranded cable #10 AWG ( 6mm2). Flush mounting plate available, order list number ZPLATE-4 2.2kg.

TVSS MODULES Each TVSS module is supplied complete with the following:

G G G G

TVSS unit as detailed above 32A TP MCCB Fittings to attach TVSS unit to panelboard Full instructions Description TVSS Module Kit LIST No. M2SSK3EG

For full details of TVSS products refer to the Transient Voltage Surge Suppression catalogue available on request.

10

Panelboard Dimensions

Panelboard Cable Space

PANELBOARD TYPES 1 & 2

250A FRAME SIZE INCOMER

630A/800A FRAME SIZE INCOMER

LUG INCOMER

TYPES 3, 4 & 5

TYPE 6

11

The First True Global Circuit Breaker Family

Eaton Series G Moulded Case Circuit Breakers (MCCBs) provide unmatched performance in a dramatically more compact package than standard circuit breakers or comparable fusible devices. Eaton MCCBs can be configured in cascade rated systems, allowing the use of lower interruption circuit breakers downstream, which leads to lower system cost. While meeting IEC 60947-2 service and interrupting ratings, these breakers provide unmatched flexibility by employing a wide variety of trip units including fixed thermal-magnetic, adjustable-thermal adjustablemagnetic, and electronic options. Eaton MCCBs are available in five frame sizes in ratings from 16 to 2500 amperes and in interrupting capacities up to 100 kA at 415V AC. Standard calibration is at 40°C with optional 50°C factory calibration available for applications where higher ambient temperatures are encountered. Eaton MCCBs use patented contact conductor designs featuring high-speed "blow-open" action that results in superior performance when high level fault currents produce extraordinary electromechanical forces.

Operating Mechanisms

In standard configuration, Eaton use a toggle handle operating mechanism which also serves as a switching position indicator. The toggle handle indicates ON, OFF and TRIPPED positions.

World Class Breakers

Advanced design, superior manufacturing and unmatched ruggedness combine to set the standard in world-class moulded case circuit breakers.

Assured Reliability Through In-plant Testing

The quality, dependability, and reliability of every Eaton MCCB is assured by a thorough program of in-plant testing. A minimum of two calibration tests are conducted on every pole of every circuit breaker to verify the trip mechanism, operating mechanism, continuity, and accuracy.

High Service Levels

The Eaton business has strategically located manufacturing plants world-wide that assemble moulded case circuit breakers. These plants employ a flexible manufacturing strategy that allows for rapid and efficient order fulfillment.

Global Certification Current Limiting Characteristics

In accordance with BSEN60947-2 / IEC 60947-2, Eaton MCCBs current limiting design is achieved with a high repulsion contact configuration and advanced arc extinguishing technology. Eaton MCCBs are also available listed in accordance with UL 489 and CSA C22.2 No. 5.1. These are independent third party testing houses who assure compliance with North American standards.

12

Trip Units

The Eaton family of electronic Digitrip trip units offers unparalleled protection and monitoring features. Digitrip RMS units provide long delay, short delay, instantaneous, and ground fault protection. Curve shaping, zone selective interlocking, system diagnostics, and system monitoring and communications are all features available by selecting the appropriate Digitrip RMS for the specific requirement. Eaton also offers electromechanical trip units that provide short circuit protection and overload protection. Conventional moulded case circuit breakers are available with either a fixed or adjustable electromechanical trip unit, depending on frame size.

Accessories

The Eaton MCCB range offers a wide choice of internal and external accessories that complement moulded case circuit breakers. Plug-in internal accessories are common for GE ­ GL ­ Frames -- 16 - 630 amperes and are suitable for field installation. The available plug-in accessories include: · Alarm switch · Auxiliary switch · Shunt trip · Low energy shunt trip · Undervoltage release mechanism

Also offered is an extensive line of handle operating accessories. These accessories provide indirect electrical or manual circuit breaker handle operations. They include: · Electrical (solenoid) operator · Motor driven electrical operator · Rotary handle · Vari-depth handle mechanism · Flex shaft handle mechanism

Temperature and Calibration

The operating ambient temperature range for most Eaton electromechanical or electronic trip units is between -20°C to +70°C. Should the internal temperature rise to an unsafe level, temperature protective circuits in the electronic designs initiate a tripping operation and provide self-protection. Standard calibration is 40°C. For applications in high ambient temperature conditions, 50°C factory calibration is available. Two basic types of termination accessories are provided; terminal connection devices and termination protection devices: · Line and load terminals · End cap keeper nut · Rear connected studs · Terminal end covers · Terminal shields

Earth Leakage Module

Features · Field installable · Self powered · Adjustable earth leakage pick-up · Adjustable time delay · Adjustment seal · Status indicator ­ led flashes to indicate proper operation · Earth fault trip alarm contact · Earth fault pre-trip alarm contact · Push-to-test & push-to-trip

13

Moulded Case Circuit Breaker Range 16A to 160A, GE-Frame

· GE-Frame MCCBs available in four breaking capacity ranges; 18kA, 25kA, 40kA & 70kA. · Current ratings 16A to160A. · User fitted, front fitting accessories. · New design around space-saving footprint. ·Current limiting action provides for low values of let-through energy.

MCCB Description 1-pole Utilisation Category Thermal Trip Magnetic Trip A Fixed 16A to 40A fixed at 500A Others fixed at 10 x In Impulse Withstand Voltage 6kV A 6kV

18kA Range 2-pole 3-pole A 6kV Fixed 1-pole A 6kV Fixed A

25kA Range 3-pole 6kV Fixed 4-pole (TPSN) A 6kV Fixed 16A to 40A fixed at 500A Others fixed at 10 x In 3-pole A 6kV

40kA Range 4-pole (TPSN) A 6kV Adjustable 0.8 to 1 x In 16A to 40A fixed at 500A Others fixed at 10 x In 3-pole A 6kV

70kA Range 4-pole (TPSN) A 6kV Adjustable 0.8 to 1 x In at 500A Others fixed at 10 x In

Fixed

Adjustable 0.8 to 1 x In 16A to 40A fixed at 500A Others fixed at 10 x In

Adjustable 0.8 to 1 x In at 500A Others fixed at 10 x In

16A to 40A fixed 16A to 40A fixed at 500A Others fixed at 10 x In at 500A Others fixed at 10 x In

16A to 40A fixed 16A to 40A fixed at 500A Others fixed at 10 x In at 500A Others fixed at 10 x In

16A to 40A fixed 16A to 40A fixed

BREAKING CAPACITY IEC60947-2/BSEN60947-2 (AC 50/60HZ) 380-415V AC 220-240V AC 25OV DC lcu (kA) Ics (kA) lcu (kA) Ics (kA) lcu (kA) Ics (kA) MCCBs Current Rating (A) 16A 20A 32A 40A 50A 63A 80A 100A 125A 160A Circuit Breaker Switches (with high magnetic trip, will trip above 1700A) Current Rating (A) 100A 125A 160A 3-pole GEK3100KSG GEK3125KSG GEK3160KSG 4-pole (TPSN) GEK4100KSG GEK4125KSG GEK4160KSG GEB1016FFG GEB1020FFG GEB1032FFG GEB1040FFG GEB1050FFG GEB1063FFG GEB1080FFG GEB1100FFG GEB1125FFG GEB2016FFG GEB2020FFG GEB2032FFG GEB2040FFG GEB2050FFG GEB2063FFG GEB2080FFG GEB2100FFG GEB2125FFG GEB3016FFG GEB3020FFG GEB3032FFG GEB3040FFG GEB3050FFG GEB3063FFG GEB3080FFG GEB3100FFG GEB3125FFG GEE1016FFG GEE1020FFG GEE1032FFG GEE1040FFG GEE1050FFG GEE1063FFG GEE1080FFG GEE1100FFG GEE1125FFG 18 14 25 13 18 14 25 13 15 8 18 14 25 13 15 8 25 13 35 18 25 13 35 18 25 13 List Number Box Clamp Type Terminals GEE3016FFG GEE3020FFG GEE3032FFG GEE3040FFG GEE3050FFG GEE3063FFG GEE3080FFG GEE3100FFG GEE3125FFG GEE4016FFG GEE4020FFG GEE4032FFG GEE4040FFG GEE4050FFG GEE4063FFG GEE4080FFG GEE4100FFG GEE4125FFG GES3020AFG GES3032AFG GES3040AFG GES3050AFG GES3063AFG GES3080AFG GES3100AFG GES3125AFG GES3160AFG GES4020AFG GES4032AFG GES4040AFG GES4050AFG GES4063AFG GES4080AFG GES4100AFG GES4125AFG GES4160AFG GEH3020AFG GEH3032AFG GEH3040AFG GEH3050AFG GEH3063AFG GEH3080AFG GEH3100AFG GEH3125AFG GEH4020AFG GEH4032AFG GEH4040AFG GEH4050AFG GEH4063AFG GEH4080AFG GEH4100AFG GEH4125AFG 25 13 35 18 25 13 40 40 85 43 35 35 40 40 85 43 35 35 70 35 100 50 42 42 70 35 100 50 42 42

Terminal Capacities (max) Dimensions (mm) A B C D Weight (kg)

70mm2

70mm2

70mm2 *

70mm2

70mm2 *

70mm2 *

70mm2 *

70mm2 *

70mm2 *

70mm2 *

25.4 140 81 92.0 0.5

50.8 140 81 92 0.9

76.2 140 81 92 1.4

25.4 140 81 92 0.5

76.2 140 81 92 1.4

101.6 140 81 92 1.8

76.2 140 81 92 1.4

101.6 140 81 92 1.8

76.2 140 81 92 1.4

101.6 140 81 92 1.8

All GE-Frame MCCBs can be supplied with 50°C ambient calibration. To order, insert V at the end of the list number eq. GEB1125FFGV or GEH4125AFGV *120mm2 capacity extension terminals available : List No 3TA160EFK (3 terminals with terminal shield) List No 4TA160EFK (4 terminals with terminal shield)

14

16A to 160A GE-Frame Auxiliaries and Accessories

ACCESSORY / AUXILIARY DESCRIPTION 1 Pole EFTS1KA EFTS1KB EFIPBK List Number 2 Pole 3 Pole EFTS2K EFTS3K EFTS2K EFTS3K EFIPBK EFIPBK EEC3K EFPHB PD50 EHMCCB EHMCCBI EHMCCR EHMVD06B EHMVD06R EHMVD12B EHMVD12R EFPHB EFPHL PD50 EFSBI EF3RTWK EFCWTK ELESE3125W EOPEF240C EOPEF240C EOPEF24D EOPEF48D EOPEF240C PAD3E 4 Pole EFTS4K EFTS4K EFIPBK EEC4K EHMCCB EHMCCBI EHMCCR EHMVD06B EHMVD06R EHMVD12B EHMVD12R EFPHB EFPHL PD50

Terminal Shield (load end) Terminal Shield (line end) Interpole Barriers (2 per pack) Terminal End Cover (Gas Barrier) Rotary Drive (Direct) Black Handle Rotary Drive (Direct) Black Handle with interlock Rotary Drive (Direct) Red Handle Vari-depth rotary drive 152mm Black Handle Vari-depth rotary drive 152mm R/Y Handle Vari-depth rotary drive 305mm Black Handle Vari-depth rotary drive 305mm R/Y Handle Handle Lock Plastic Handle Lock Metal Handle Lock Padlock Front mounted sliding bar interlock End Cap Set Metric - Line Side Control wire terminal kit (12 pack) Earth Leakage Module (125A max.) Motor Operator 120 Vac Motor Operator 240 Vac Motor Operator 24 Vdc Motor Operator 48 Vdc Motor Operator 125 Vdc Plug in Block (incl power conns & safety trip) Shunt Trips Shunt Trip 24-48Vdc Shunt Trip 120-240Vac Shunt Trip 380-600Vac Undervoltage Releases UVR 12Vac/dc UVR 24Vac/dc UVR 48Vac UVR 48Vdc UVR 120Vac UVR 120Vdc UVR 208-240Vac UVR 220-250Vdc UVR 308-500Vac UVR 525-600Vdc Other Auxiliaries Auxiliary Switch 1NO/NC Auxiliary Switch 2NO/NC Auxiliary/Alarm Switch 1NO/NC Alarm Switch 1NO/NC Alarm Switch 2NO/NC

EFPHB PD50 -

EFCWTK -

EFCWTK -

EF4RTWK EFCWTK ELESE4125W EOPEF240C EOPEF240C EOPEF24D EOPEF48D EOPEF240C PAD4E

-

-

-

-

SNT060CPK SNT120CPK SNT480APK

SNT060CPK SNT120CPK SNT480APK

-

-

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

-

-

AUX1A1BPK AUX2A2BPK AUXALRMEPK ALM1M1BEPK ALM2M2BEPK

AUX1A1BPK AUX2A2BPK AUXALRMEPK ALM1M1BEPK ALM2M2BEPK

15

Moulded Case Circuit Breaker Range 50A to 250A, GJ-Frame

· GJ-Frame MCCBs available in two breaking capacity ranges; 40kA & 70kA. · Choice of thermal/magnetic or electronic trip units. · User fitted, front fitting accessories. · New design around space-saving footprint. ·Current limiting action provides for low values of let-through energy.

Thermal Magnetic Trip Unit Range MCCB Description 3-pole Utilisation Category Impulse Withstand Voltage Thermal Trip Magnetic Trip A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 40kA Range 4-pole (TPSN) A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 3-pole A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 70kA Range 4-pole (TPSN) A 8kV 3-pole A 8kV

Electronic Trip Unit (Digitrip RMS 310 LSI) Range 40kA Range 4-pole (TPSN) A 8kV 3-pole A 8kV 70kA Range 4-pole (TPSN) A 8kV

Adjustable 0.8 to 1 x In Adjustable 0.5 to 1 x In Adjustable 5 to 10 x In Adjustable 2 to 14 x In

Adjustable 0.5 to 1 x In Adjustable 0.5 to 1 x In Adjustable 0.5 to 1 x In Adjustable 2 to 14 x In Adjustable 2 to 14 x In Adjustable 2 to 14 x In

BREAKING CAPACITY IEC60947-2/BSEN60947-2 (AC 50/60HZ) 660-690V AC lcu (kA) 12 Ics (kA) 6 380-415V AC lcu (kA) 40 Ics (kA) 40 220-240V AC lcu (kA) 85 Ics (kA) 85 25OV DC lcu (kA) 35 Ics (kA) 35 MCCBs Current Rating (A) 50A 80A 100A 125A 160A 200A 250A GJS3080AAG GJS3100AAG GJS3125AAG GJS3160AAG GJS3200AAG GJS3250AAG GJS4080AAG GJS4100AAG GJS4125AAG GJS4160AAG GJS4200AAG GJS4250AAG GJH3080AAG GJH3100AAG GJH3125AAG GJH3160AAG GJH3200AAG GJH3250AAG GJH4080AAG GJH4100AAG GJH4125AAG GJH4160AAG GJH4200AAG GJH4250AAG GJS325032G GJS425032G GJH325032G GJH425032G GJS316032G GJS416032G GJH316032G GJH416032G GJS310032G GJS410032G GJH310032G GJH410032G 12 6 40 40 85 85 35 35 14 7 70 70 100 100 42 42 14 7 70 70 100 100 42 42 List Number Box Clamp Type Terminals GJS305032G GJS405032G GJH305032G GJH405032G 12 6 40 40 85 85 12 6 40 40 85 85 14 7 70 70 100 100 14 7 70 70 100 100

Current Rating (A) 50A 80A 100A 125A 160A 200A 250A GJS3080AAM GJS3100AAM GJS3125AAM GJS3160AAM GJS3200AAM GJS3250AAM GJS4080AAM GJS4100AAM GJS4125AAM GJS4160AAM GJS4200AAM GJS4250AAM GJH3080AAM GJH3100AAM GJH3125AAM GJH3160AAM GJH3200AAM GJH3250AAM

Bolt Type Terminals GJS305032M GJH4080AAM GJH4100AAM GJH4125AAM GJH4160AAM GJH4200AAM GJH4250AAM GJS325032M GJS425032M GJH325032M GJH425032M GJS316032M GJS416032M GJH316032M GJH416032M GJS310032M GJS410032M GJH310032M GJH410032M GJS405032M GJH305032M GJH405032M

Circuit Breaker Switches (with high magnetic trip, will trip above 2500A) Current Rating (A) 160A 200A 250A Current Rating (A) 160A 200A 250A Terminal Capacities Box Clamp Terminal Capacity (max) Bolt Type Terminal Size Dimensions (mm) A B C D Weight (kg) 105 177.8 87.4 118 5.2 135.6 177.8 87.4 118 7 105 177.8 87.4 118 5.2 135.6 177.8 87.4 118 7 105 177.8 87.4 118 5.2 135.6 177.8 87.4 118 7 105 177.8 87.4 118 5.2 135.6 177.8 87.4 118 7 150mm2 M8 150mm2 M8 150mm2 M8 150mm2 M8 150mm2 M8 150mm2 M8 150mm2 M8 150mm2 M8 Box Clamp Type Terminals GJK3160KSG GJK3200KSG GJK3250KSG GJK3160KSG GJK3200KSG GJK3250KSG GJK4160KSG GJK4200KSG GJK4250KSG GJK4160KSG GJK4200KSG GJK4250KSG

Bolt Type Terminals

All thermal magnetic J-Frame MCCBs can be supplied with 50°C ambient calibration. To order, insert V at the end of the list number eq. GJS3250AAGV or GJH4250AAMV

16

Electronic trip J Frame MCCBs are suitable for 40°C or 50°C applications

50A to 250A GJ-Frame Auxiliaries and Accessories

ACCESSORY / AUXILIARY DESCRIPTION List Number Terminal Shield (1 per pack) Interpole Barriers (2 per pack) 3 Pole FJTS3K FJIPBK 4 Pole FJTS4K FJIPBK4

Rotary Drive (Direct) Black Handle Rotary Drive (Direct) Black Handle with interlock Rotary Drive (Direct) Red Handle Vari-depth rotary drive 152mm Black Handle Vari-depth rotary drive 152mm R/Y Handle Vari-depth rotary drive 305mm Black Handle Vari-depth rotary drive 305mm R/Y Handle Handle Lock Plastic Handle Lock Metal padlockable Handle Lock Padlock Front mounted sliding bar interlock Walking beam interlock Key Interlock Kit (provision only) End Cap Set Metric Control wire terminal kit (14 pack) Earth Leakage Module (160A max.) Earth Leakage Module (250A max.) Motor Operator 120 Vac Motor Operator 240 Vac Motor Operator 24 Vdc Motor Operator 48 Vdc Motor Operator 125 Vdc Plug in Block (incl power conns & safety trip) Digitrip Test Set (230V) Shunt Trips Shunt Trip 24-48Vdc Shunt Trip 120-240Vac Shunt Trip 380-600Vac Undervoltage Releases UVR 12Vac/dc UVR 24Vac/dc UVR 48Vac UVR 48Vdc UVR 120Vac UVR 120Vdc UVR 208-240Vac UVR 220-250Vdc UVR 308-500Vac UVR 525-600Vdc Other Auxiliaries Auxiliary Switch 1NO/NC Auxiliary Switch 2NO/NC Auxiliary/Alarm Switch 1NO/NC Alarm Switch 1NO/NC Alarm Switch 2NO/NC

JHMCCB JHMCCBI JHMCCR FJHMVD06B FJHMVD06R FJHMVD12B FJHMVD12R FJPHB FJPHL PD50 FJSBI FJWBI KYKFJ FJ3RTWK FJCWTK ELJBE3160W ELJBE3250W EOPFJ240C EOPFJ240C EOPFJ24D EOPFJ48D EOPFJ240C PAD3J MTST 230V

JHMCCB JHMCCBI JHMCCR FJHMVD06B FJHMVD06R FJHMVD12B FJHMVD12R FJPHB FJPHL PD50

KYKFJ FJ4RTWK FJCWTK ELJBE4160W ELJBE4250W EOPFJ240C EOPFJ240C EOPFJ24D EOPFJ48D EOPFJ240C PAD4J MTST 230V

SNT060CPK SNT120CPK SNT480APK

SNT060CPK SNT120CPK SNT480APK

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

AUX1A1BPK AUX2A2BPK AUXALRMJPK ALM1M1BJPK ALM2M2BJPK

AUX1A1BPK AUX2A2BPK AUXALRMJPK ALM1M1BJPK ALM2M2BJPK

17

Moulded Case Circuit Breaker Range 250A to 630A, GL-Frame

· GL-Frame MCCBs Available in two breaking capacity ranges; 50kA & 70kA. · Choice of thermal/magnetic or electronic trip units. · User fitted, front fitting accessories. · New design around space-saving footprint. ·Current limiting action provides for low values of let-through energy.

Thermal Magnetic Trip Unit Range MCCB Description 3-pole Utilisation Category Impulse Withstand Voltage Thermal Trip Magnetic Trip A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 50kA Range 4-pole (TPSN) A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 3-pole A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 70kA Range 4-pole (TPSN) A 8kV Adjustable 0.8 to 1 x In Adjustable 5 to 10 x In 3-pole A 8kV

Electronic Trip Unit (Digitrip RMS 310 LSI) Range 50kA Range 4-pole (TPSN) A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In 3-pole A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In 70kA Range 4-pole (TPSN) A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In

Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In

BREAKING CAPACITY IEC60947-2/BSEN60947-2 (AC 50/60HZ) 660-690V AC 380-415V AC 220-240V AC 25OV DC lcu (kA) Ics (kA) lcu (kA) Ics (kA) lcu (kA) Ics (kA) lcu (kA) Ics (kA) MCCBs Current Rating (A) 250A 320A 400A 500A 630A Current Rating (A) 250A 320A 400A 500A 630A GLS3250AAM GLS3320AAM GLS3400AAM GLS3500AAM GLS3630AAM GLS4250AAM GLS4320AAM GLS4400AAM GLS4500AAM GLS4630AAM GLH3250AAM GLH3320AAM GLH3400AAM GLH3500AAM GLH3630AAM GLS3250AAG GLS3320AAG GLS3400AAG GLS3500AAG GLS3630AAG GLS4250AAG GLS4320AAG GLS4400AAG GLS4500AAG GLS4630AAG GLH3250AAG GLH3320AAG GLH3400AAG GLH3500AAG GLH3630AAG 20 10 50 50 85 85 22 22 20 10 50 50 85 85 22 22 25 13 70 70 100 100 42 42 25 13 70 70 100 100 42 42 List Number Box Clamp Type Terminals GLH4250AAG GLH4320AAG GLH4400AAG GLH4500AAG GLH4630AAG Bolt Type Terminals GLH4250AAM GLH4320AAM GLH4400AAM GLH4500AAM GLH4630AAM GLS363032M GLS463032M GLH363032M GLH463032M GLS363032G GLS463032G GLH363032G GLH463032G 20 10 50 50 85 85 20 10 50 50 85 85 25 13 70 70 100 100 25 13 70 70 100 100

Circuit Breaker Switches (with high magnetic trip) Current Rating (A) 400A (will trip above 4000A) 630A (will trip above 6300A) Current Rating (A) 400A (will trip above 4000A) 630A (will trip above 6300A) Terminal Capacities Box Clamp Terminal Capacity (max) Bolt Type Terminal Size Dimensions (mm) A B C D Weight (kg) 140 257.3 103.1 140 7.3 183 257.3 103.1 140 9.1 140 257.3 103.1 140 7.3 183 257.3 103.1 140 9.1 140 257.3 103.1 140 7.3 183 257.3 103.1 140 9.1 140 257.3 103.1 140 7.3 183 257.3 103.1 140 9.1 240 mm2 M10 240 mm2 M10 240 mm2 M10 240 mm2 M10 240 mm2 M10 240 mm22 M10 240 mm2 M10 240 mm2 M10 Box Clamp Type Terminals GLK3400KSG GLK3630KSG GLK3400KSM GLK3630KSM GLK4400KSG GLK4630KSG GLK4400KSM GLK4630KSM

Bolt Type Terminals

All thermal magnetic L-Frame MCCBs can be supplied with 50°C ambient calibration. To order, insert V at the end of the list number eq. GLS3630AAGV or GLH4630AAMV Electronic trip L Frame MCCBs are suitable for 40°C or 50°C applications

18

250A to 630A GL-Frame Auxiliaries and Accessories

ACCESSORY / AUXILIARY DESCRIPTION List Number Terminal Shield (1 per pack) Interpole Barriers (2 per pack) 3 Pole LTS3K LHIPBK 4 Pole LT4SK LHIPBK

Rotary Drive (Direct) Black Handle Rotary Drive (Direct) Black Handle with interlock Rotary Drive (Direct) Red Handle Vari-depth rotary drive 152mm Black Handle Vari-depth rotary drive 152mm R/Y Handle Vari-depth rotary drive 305mm Black Handle Vari-depth rotary drive 305mm R/Y Handle Handle Lock Handle Block Handle Lock Padlock Front mounted sliding bar interlock 3P-3P Front mounted sliding bar interlock 4P-4P Walking beam interlock 3P-3P Walking beam interlock 4P-4P Key Interlock Kit (provision only)

LHMCCB LHMCCBI LHMCCR KLHMVD06B KLHMVD06R KLHMVD12B KLHMVD12R LBHP LPHL PD50 SBKL3 WBLL3630 KYKL

LHMCCB LHMCCBI LHMCCR KLHMVD06B KLHMVD06R KLHMVD12B KLHMVD12R LBHP LPHL PD50 SBKL4 WBLL4630 KYKL

End Cap Set Metric Terminal extensions Terminal spreaders Earth Leakage Module (400A max.) Earth Leakage Module (630A max.) Motor Operator 120 Vac Motor Operator 240 Vac Motor Operator 24 Vdc Motor Operator 48 Vdc Motor Operator 125 Vdc Plug in Block incl power conns & safety trip Digitrip Test Set (230V) Shunt Trips Shunt Trip 24-48Vdc Shunt Trip 120-240Vac Shunt Trip 380-600Vac Undervoltage Releases UVR 12Vac/dc UVR 24Vac/dc UVR 48Vac UVR 48Vdc UVR 120Vac UVR 120Vdc UVR 208-240Vac UVR 220-250Vdc UVR 308-500Vac UVR 525-600Vdc Other Auxiliaries Auxiliary Switch 1NO/NC Auxiliary Switch 2NO/NC Auxiliary/Alarm Switch 1NO/NC Alarm Switch 1NO/NC Alarm Switch 2NO/NC

L3RTWK LGTEW3 LGTES3 ELLBE3400W ELLBE3630W EOPLG240C EOPLG240C EOPLG24D EOPLG48D EOPLG240C PAD3L MTST230V

L4RTWK LGTEW4 LGTES4 ELLBE4400W ELLBE4630W EOPLG240C EOPLG240C EOPLG24D EOPLG48D EOPLG240C PAD4L MTST230V

SNT060CPK SNT120CPK SNT480APK

SNT060CPK SNT120CPK SNT480APK

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

UVR012CPK UVR024CPK UVR048APK UVR048DPK UVR120APK UVR125DPK UVR240APK UVR250DPK UVR480APK UVR600APK

AUX1A1BPK AUX2A2BPK AUXALRMJPK ALM1M1BJPK ALM2M2BJPK

AUX1A1BPK AUX2A2BPK AUXALRMJPK ALM1M1BJPK ALM2M2BJPK

19

Moulded Case Circuit Breaker Range 800A to 1600A, GN-Frame

· GN-Frame MCCBs available in two breaking capacity ranges; 50kA & 70kA. · Electronic trip units. · LSI or LSIG Protection. ·Current limiting action provides for low values of let-through energy.

Electronic Trip Unit (Digitrip RMS 310 LSI) Range MCCB Description 3-pole Utilisation Category Thermal Trip Magnetic Trip A Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In Impulse Withstand Voltage 8kV 50kA Range 4-pole (TPSN) A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In 3-pole A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In 70kA Range 4-pole (TPSN) A 8kV Adjustable 0.5 to 1 x In Adjustable 2 to 8 x In

BREAKING CAPACITY IEC60947-2/BSEN60947-2 (AC 50/60HZ) 660-690V AC 380-415V AC 220-240V AC lcu (kA) Ics (kA) lcu (kA) Ics (kA) lcu (kA) Ics (kA) MCCBs Current Rating (A) 800A 1250A 1600A GNS3800T32WP19 GNS3125T32WP09 GNS316T32WP35 GNS4800T32WP19 GNS4125T32WP09 GNS416T32WP35 GNH3800T32WP19 GNH3125T32WP09 GNH4800T32WP19 GNH4125T32WP09 20 10 50 50 85 85 20 10 50 50 85 85 List Number 25 13 70 50 100 100 25 13 70 50 100 100

Circuit Breaker Switches (with high magnetic trip, will trip above 12,500A) Current Rating (A) 800A 1250A Bolt Type Terminal Size Dimensions (mm) A B C D Weight (kg) 210 406.4 139.7 188 21.3 280 406.4 139.7 188 28.3 210 406.4 139.7 188 21.3 280 406.4 139.7 188 28.3 GNK3800KSW GNK3125KSW M12 GNK4800KSW GNK4125KSW M12 M12 M12

N Frame MCCBs are suitable for 40° or 50°C applications

20

800A to 1600A GN-Frame Auxiliaries and Accessories

ACCESSORY / AUXILIARY DESCRIPTION List Number 3 Pole HMVD5B LKD4 PLK5 PD50 HEX5 SBK5 WBL5 KYK4 EOP5T07 EOP5T11 EOP5T21 EOP5T22 EOP5T26 STK2 4 Pole HMVD5B LKD4 PLK5 PD50 HEX5 SBK5 WBL5 KYK4 EOP5T07 EOP5T11 EOP5T21 EOP5T22 EOP5T26 STK2

Vari-depth rotary drive 305mm Black Handle Handle Lock Handle Block Handle Lock Padlock Handle extension Front mounted sliding bar interlock 3P-3P Front mounted sliding bar interlock 4P-4P Walking beam interlock 3P-3P Walking beam interlock 4P-4P Key Interlock Kit (provision only) Motor Operator 120 Vac Motor Operator 240 Vac Motor Operator 24 Vdc Motor Operator 48 Vdc Motor Operator 125 Vdc Digitrip Test Set Shunt Trips Shunt Trip 24 Vdc Shunt Trip 48Vdc Shunt Trip 120-240Vac Shunt Trip 220-250Vdc or 380-440Vac Shunt Trip 480-600Vac Low Energy Flux Shunt Trip Undervoltage Releases UVR 24Vac/dc UVR 48Vdc UVR 120Vac UVR 208-240Vac Other Auxiliaries Auxiliary Switch 1NO/NC Auxiliary Switch 2NO/NC Auxiliary Switch 3NO/NC Auxiliary/Alarm Switch 1NO/NC Alarm Switch 1NO/NC Alarm Switch 2NO/NC

SNT5LP03K SNT5LP23K SNT5LP11K SNT5LP14K SNT5LP18K LST5LPK

SNT5LP03K SNT5LP23K SNT5LP11K SNT5LP14K SNT5LP18K LST5LPK

UVH5LP21K UVH5LP23K UVH5LP08K UVH5LP11K

UVH5LP21K UVH5LP23K UVH5LP08K UVH5LP11K

A1X5RPK A2X5RPK A3X5RPK AA115RPK A1L5RPK A2L5RPK

A1X5RPK A2X5RPK A3X5RPK AA115RPK A1L5RPK A2L5RPK

21

Eaton's Electrical business is a global leader in electrical control, power distribution, and industrial automation products and services. Through advanced product development, world-class manufacturing methods, and global engineering services and support, Eaton's Electrical business provides customer-driven solutions under brand names such as Cutler-Hammer®, Durant®, Heinemann®, Holec® and MEM®, which globally serve the changing needs of the industrial, utility, light commercial, residential, and OEM markets. For more information, visit www.EatonElectrical.com. Eaton Corporation is a diversified industrial manufacturer with 2004 sales of $9.8 billion. Eaton is a global leader in fluid power systems and services for industrial, mobile and aircraft equipment; electrical systems and components for power quality, distribution and control; automotive engine air management systems, powertrain solutions and speciality controls for performance, fuel economy and safety; and intelligent truck drivetrain systems for safety and fuel economy. Eaton has 55,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com.

Eaton Electric Limited Reddings Lane Birmingham B11 3EZ tel: 0121 685 2100 fax: 0121 706 2012 www.eatonelectrical.co.uk Customer Support Services All enquiries telephone: 08700 545 333 Commercial, Industrial & Automation Products: fax: 08700 540 333 e-mail: [email protected] Residential /Consumer Products: fax: 08700 540 333 e-mail: [email protected] Low / Medium Voltage Systems Support: fax: 08700 507 520 e-mail: [email protected] Crane Control: fax: 08700 507 530 e-mail: [email protected]

© 2005 Eaton Electric Limited. All rights reserved. Partial or complete reproduction is granted with written permission of Eaton Electrical. Printed in the UK CAT 958/Sept 05

Information

24 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

1133739