Read 780A-0605 Gibson GB3B(M,V) Air Handler tsl.PMD text version

TECHNICAL SPECIFICATIONS

GB3B(M,V) Series Air Handler

10 and 12 SEER Residential System 18,000 - 60,000 Btuh (Heat Pump & Air Conditioner)

The GB3B(M,V) Series of air handlers, when combined with our heat pump or air conditioner, offer a full line of quality, split system heating and cooling equipment.

FEATURES and BENEFITS

· Durable, Attractive Cabinet -- Designed using galvanized steel. The door is also galvanized steel, with a polyester urethane finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units. The plastic drain pan is corrosion-resistant. · Multi-poised -- Can be used in horizontal, upflow, downflow and vertical applications (GB3BM only). · Multi-speed -- Gives flexibility of installation. · Ease-of-Service -- Plug-in wire connections and builtin filter rack makes the air handler easy to service. · Plug-in Heater Kits -- Available in 5kw - 20 kw (Not for use in 115 Volt units) · Breaker Accessibility -- Breaker accessible from front of unit when heater is applied. · No Fasteners on Sides or Back -- Smooth surfaces for ease of installation. · Warranty -- Five year limited all parts warranty, a major benefit to the consumer.

MODEL IDENTIFICATION CODE GB

Indoor Air Handler Design Series Motor: B = 3 or 4 speed Configuration: M = Multipoise V = Vertical Only

3

B

M

-

036

K -

B -

10

Strip Heat (kw) Cabinet Identifier A = 14 1/4" Width B = 19 3/4" Width C = 22 1/2" Width Electrical Code K = 208/230-60-1

Nominal Capacity (000) Btuh

SPECIFICATIONS

Model Number GB3B(M,V)Nominal Cooling Capacity - Btuh (1) Refrigerant Flow Control (2) Maximum Available (3) Auxiliary Heat (kw) Nominal Blower Size (D x W) (H.P. - Speed - Type) Rated External Static Pressure (in. W.C.) CFM @ Rated ESP Filter Size (4) Approximate Shipping Weight (lbs.) 024K-A 24,000 030K-A 30,000 036K-A 36,000 .067 14 10 x 6

1/3-3-PSC

030K-B 30,000 .063 20 10 x 8

1/3-3-PSC

036K-B 36,000 .067 20 10 x 8

1/3-3-PSC

042K-B 42,000 .075 20 10 x 8

1/3-3-PSC

048K-B 48,000 .080 20 10 x 8

1/2-3-PSC

060K-C 60,000 .093 20 10 x 10

3/4-3-PSC

066K-C 60,000 .103 20 10 x 10

3/4-3-PSC

.060 (.051)* .063 (.067)* 10 10 x 6

1/5-3-PSC

14 10 x 6

1/3-3-PSC

.30 880

12 x 20 x 1

.35 1150

12 x 20 x 1

.35 1150

12 x 20 x 1

.35 1250

18 x 20 x 1

.35 1250

18 x 20 x 1

.35 1300

18 x 20 x 1

.40 1450

18 x 20 x 1

.40 1880

20 x 20 x 1

.40 1920

20 x 20 x 1

75

85

85

105

105

110

140

145

155

(1) See current ARI Directory for certified combinations and ratings. (2) Units are 10 SEER air conditioner ready as shipped. (3) Heater kits not applicable to 115 Volt units. (4) Filter is field supplied. * Additional orifice shipped with unit

ACCESSORIES

Accessory Kit Description Downflow Adaptor Kit Single Circuit Adaptor Kit GB3BV Horizontal Drain Pan Conversion Kit Variable Speed Kit Cabinet Size A B C X X X X X X X X X X Order Number 917342 917343A 917344A 913874 903749 903764B 903765B

**240V Single Phase Electric Heat Kits

No. of Stages 1 1 1 1 1 1 Order Number Approved with Circuit w/o Circuit for Cabinet Breaker(s) Breaker(s) A, B, C 917367B 917366B A, B, C 917370B 917368B A, B, C 917374B 917372B A, B, C 904198B N/A B, C 903959B N/A B, C 903960B N/A

KW 5 8 10 12 15 20

**240V 3-Phase Electric Heat Kits

No. of Stages 1 1 Order Number Approved with Circuit w/o Circuit for Cabinet Breaker(s) Breaker(s) B, C 917449 N/A B, C 917450 N/A

KW 9 15

**Not for use with 115 Volt units.

2

DIMENSIONS

Model Number GB3B(M,V)024K-A 030K-A 036K-A 030K-B 036K-B 042K-B 048K-B 060K-C 066K-C H 41 1/2 41 1/2 41 1/2 43 1/2 43 1/2 43 1/2 43 1/2 43 1/2 53 1/2 W 14 1/4 14 1/4 14 1/4 19 3/4 19 3/4 19 3/4 19 3/4 22 1/2 22 1/2 A 12 3/4 12 3/4 12 3/4 18 1/4 18 1/4 18 1/4 18 1/4 21 21

3/4" 3/4"

Refrigerant Connections Suction Dia. Liquid Dia. 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8

3/4"

Filter Size 12 x 20 x 1 12 x 20 x 1 12 x 20 x 1 18 x 20 x 1 18 x 20 x 1 18 x 20 x 1 18 x 20 x 1 20 x 20 x 1 20 x 20 x 1

Supply Air Duct Dimension 12 7/8 x 12 3/4 12 7/8 x 12 3/4 12 7/8 x 12 3/4 12 7/8 x 18 1/4 12 7/8 x 18 1/4 12 7/8 x 18 1/4 12 7/8 x 18 1/4 12 7/8 x 21 12 7/8 x 21

12 7/8"

1 1/8" K.O. A 7/8" K.O. 1 1/8" K.O. 1 1/8" 2 7/8" 1 3/4" 1 7/8" K.O. 3/4" 7/8" K.O. 1" 1 7/8" K.O. 1 1/4" 3 1/4 1 1/2" 1 3/4" 2" 1 1/2"

1 1/8" K.O. (2)

H

3 1/4" 2 1/4"

SUCTION LIQUID

15 7/8" 13 5/8"

W

3/4"

22"

3

SYSTEM AIR FLOW DATA

Unit HP 1/5 HP 10 X 6 Speed ESP ("H2O)

0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5 0.1 0.2 0.3 0.4 0.5

CFM Low

620 580 520 460 400 860 840 800 750 720 860 840 800 750 720 920 890 820 760 690 920 890 820 760 690 920 890 820 760 690 1510 1470 1390 1320 1250 1840 1780 1710 1640 1570 1880 1820 1750 1680 1610

CFM Med

750 730 680 630 580 1100 1090 1040 990 950 1100 1090 1040 990 950 1230 1190 1120 1050 980 1230 1190 1120 1050 980 1230 1190 1120 1090 980 1620 1580 1490 1410 1340 1990 1930 1860 1790 1710 2030 1970 1900 1830 1750

CFM High

950 930 880 830 770 1250 1230 1170 1120 1070 1250 1230 1170 1120 1070 1420 1380 1290 1210 1130 1420 1380 1290 1210 1130 1420 1380 1300 1210 1130 1690 1650 1510 1450 1380 2090 2060 1980 1880 1810 2130 2100 2020 1920 1850

Notes:

1) Airflow is shown in cfm,

024A

3

030A

1/3 HP 10 X 6

3

036A

1/3 HP 10 X 6

3

030B

1/3 HP 10 X 8

3

036B

1/3 HP 10 X 8

3

042B

1/3 HP 10 X 8

3

048B

1/2 HP 10 X 8

3

+/- 5%. 2) External static pressure is shown in inches w.c. 3) All airflows are measured without filter and with dry coil. For filter velocity of 300 ft./ min. subtract .08" external static pressure. For wet coil, subtract .1" external static pressure. 4) See unit nameplate or installation instructions for maximum recommended external static pressure.

060C

3/4 HP 10 X 10

3

066C

3/4 HP 10 X 10

3

ELECTRICAL DATA

Standard Air Handler

Min. Circuit Ampacity Model Number H4HK Voltage 240 240 240 240 240 240 208 208 208 208 208 208 240 240 208 208 KW 4.8 7.5 9.6 11.6 14.4 19.2 3.6 5.6 7.2 8.8 10.8 14.4 9.0 14.4 6.8 10.8

Circuit Circuit Single

Variable Speed Air Handler

Min. Circuit Ampacity

Circuit Circuit Single

Max. OverCurrent Protection

Circuit Circuit Single

Max. OverCurrent Protection

Circuit Circuit Single

A 35.2 55.0 55.0 31.4 48.3 48.3 -

B 30.2 25.0

Circuit

A 40 60 60 40 50 50 -

B 40 30 50 30 30 50 -

Circuit

A 39.0 59.3 59.3 35.2 52.5 52.5 -

B 30.2 25.0

Circuit

A 40 60 60 40 60 60 -

B 40 30 50 30 30 50 -

Circuit

005H-XXB 008H-XXB 010H-XXB 012H-XXB 015H-XXB 020H-XXB 005H-XXB 008H-XXB 010H-XXB 012H-XXB 015H-XXB 020H-XXB 009Q-XXB 015Q-XXB 009Q-XXB 015Q-XXB

30.0 44.1 55.0 65.4 80.0

30 50 60 70 90 125 30 40 50 60 70 100 35 50 30 45

34.8 47.8 58.8 69.2 83.8

40 50 60 70 90 125 40 50 60 70 80 100 40 60 35 50

50.0 105.0 26.4 21.6 43.3 26.6 38.8 48.3 57.9 69.7 91.5 32.4 48.7 28.8 42.9

50.0 108.8 26.4 21.6 43.3 30.9 43.1 52.5 61.6 74.2 95.8 35.8 52.1 32.2 46.3

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI

780A-0605 (Replaces 780A-0104)

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligation. Printed in U.S.A. (06/05)

O'Fallon, MO

Information

780A-0605 Gibson GB3B(M,V) Air Handler tsl.PMD

4 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

835550