Piranha2 P2-4x-xxx40

Line Scan Cameras

Overview

Resolution up to 8k with proven performance

Key Features 160MHz throughput Resolutions from 4k to 8k High responsivity Medium Camera Link Single 12V to 15V power supply Slimline: 76mm x 105mm x 50mm (6K, 8k) Standard: 85mm x 85mm x 50mm (4K, 6k, 8k) Programmability Programmable pixel-to-pixel correction Adjustable analog and digital gain Analog and digital offset control 8 or 10 bit selectable output Adjustable integration time and line rate Test pattern, line statistics, and camera diagnostics Typical Applications Flat panel display inspection Printed circuit board inspection High performance document scanning/image lift Postal/parcel sorting

Piranha2 takes performance to a higher level. Four 8 or 10 bit outputs at 40MHz deliver 160MHz throughput, and boosted responsivity means the Piranha2 needs less light than the original Piranha, even at higher speed. Available in resolutions from 4k to 8k, the camera is small, light, and uses a single power supply. The compact design is shallower than previous models and the new slimline design (76mm x 105mm x 50mm) is even narrower than our original Piranha2 products for easier mounting and minimized optical path. Cabling and interface are simplified with the Camera LinkTM high speed serial standard. The camera is more sensitive, but still provides quieter, more uniform output thanks to CDS (correlated double sampling) and embedded flat field correction algorithms. Gain and offset are fully programmable for each output channel, and the camera can output test patterns for cable/system troubleshooting. All these features combine to make Piranha2 one of the most powerful linescan cameras in the world. Set it loose on your toughest imaging challenge. Specifications Resolution Data Rate Max. Line/Frame Rate Pixel Size Data Format Lens Mount Responsivity Dynamic Range Nominal Gain Range Size Mass Operating Temp Power Supply Power Dissipation Regulatory Compliance Control Data Power Example Part Number 4096 / 6144 / 8192 4x40MHz 36 / 24 / 18kHz 7µm x 7µm 4x8/ 4x10 bit Med Camera Link See Chart 38DN/(nJ/cm²) @10dB up to 496:1 ±10dB 85x85x50/50x85x50/76x105x50 <500g 10-50ºC 12 to 15V <10W CE MDR26 Camera Link Shared with Control Hirose HR10 6 pin P2-42-06K40

39

Piranha2 P2-4x-xxx40

Line Scan Cameras

From concept to design, our Piranha2 cameras lead where others can only follow. Our 6k & 8k resolutions have over 1000 installations by themselves.

Worldwide Sales, 605 McMurray Rd.,Waterloo, Ontario, Canada N2V 2E9 Tel: 1.519.886.6000 [email protected] European Sales, Breslauer Str. 34, D-82194 Gröbenzell (Munich), Germany Tel: +49.8142.46770 [email protected] Asia Pacific Sales, 2-40-2 Ikebukuro,Toshimo-ku, Tokyo, 171-0014, Japan Tel: +813.5960.6353 [email protected]

11-Oct-05 03-70-00106-13 www.dalsa.com

User Supplement P2-42-02K40-50E

This document supplements the Piranha2 User Manual (03-32-00493) and details how the P2-42-02K40-50E differs from the models explained in the user manual.

Sensor

The P2-42-02K40-50E uses the IT-P1-2048D output image sensor with 10µm square pixels and 100% fill factor.

Figure 1: IT-P1-2048D Sensor Drawing

1 Relative position of package Pin 1

DALSA

03-32-10065-01

P2-42-02K40-50E User's Supplement

PRELIMINARY

2

Performance Specifications

The following two tables list the P2-42-02K40-50E's performance specifications. The first table lists the operating ranges of the camera, and the second table lists the performance specifications at minimum, nominal and maximum gain levels at 1kHz data rate. Note that as gain levels increase, performance decreases, because your signal to noise decreases. Also note that the cameras performance specifications were obtained using a line rate of only 1kHz. At low line rates, dark current can become a significant source of noise and appears in specifications such as FPN, PRNU, and noise. If you operate the camera at faster line rates, such as 10kHz or greater, the amount of dark current will be reduced by 10x or greater.

Table 1. P2-42-02K40-50E Operating Requirements and Ranges Operating Requirements Units

Power Power Supply Current (Vin = +12V) Time to power up, typ Time to calibrate (FPN/PRNU) W mA sec. sec.

Typical

8.5 700 15 19

Notes

Operating Ranges

Data Rate, per tap Line Rate Temperature Front plate Temperature Temperature drift before recalibration, (recommendation)

Units

MHz kHz °C °C

Min

40 1 10

Max

40 68 50 10

Notes

2

Note that the environment conditions represent the state of the environment when the camera was being tested. Typical results are the average values obtained with at a 1kHz line rate and 30°C. Maximum results represent the worst case results from any camera operating at 50°C with a 1kHz line rate.

DALSA

03-32-10065-02

P2-42-02K40-50E User's Supplement

PRELIMINARY

3

Table 2. P2-42-02K40-50E Performance Specifications, 1kHz line rate Min. Gain Nom. Gain Max. Gain Notes

2 3 3 1 1

Max

Max

Environment Conditions

Data Rate Line Rate Gain Setting Front Plate Temperature

Units

MHz kHz dB °C

40 -10

40 1 -10 30

40 1 -10 50

40 0

40 1 0 30

40 1 0 50

40 +10

40 1 +10 30

40 1 +10 50

Max

76 32 4 27 8 39 5/27 17

Min

Min

Min

Typ

Typ

Typ

Max

Max

Units

DN/(nJ/cm2) Ratio DN DN DN DN DN DN DN

Broadband Responsivity Dynamic Range Pk-Pk Noise, max RMS Noise, max FPN uncorrected FPN corrected, max PRNU uncorrected ECD/ECE PRNU corrected ECD/ECE DC Offset

6 496:1

6.8 2 0.5 1.1 0.3 5 1.5/2 2

7.6 3 0.5 4 2 18 3/3 3

18.8 207:1

21.4 390:1 4 0.75 3.5 1 5 1.2/1.5 5

24 8 1.2 8 2 23 3/8 5

60 62:1

68 135:1 15 2.2 8 2 8/10 2/3.5 7

Notes: DN = Digital Numbers (0-255); also known as gray levels. ECE = Exposure Control Enabled ECD = Exposure Control Disabled · · · 1. 2. 3. All measurements taken in 8-bit output mode. All measurements are valid for front plate temperatures in still air. All measurements used a Tungsten halogen light source, 3200K bulb temp., and 750nm cutoff filter Due to FPN/PRNU correction calculations, certain digital numbers will be unavailable when outputting 10 bits with FPN/PRNU correction. Measured at front plate. The corresponding ambient temperature range with still air is 0°C - 37°C. Measurements taken at maximum line rates.

DALSA

03-32-10065-02

Max

Min

Min

Min

Typ

Typ

Typ

Electro-Optic Specifications

Notes

P2-42-02K40-50E User's Supplement

PRELIMINARY

4

Software Commands

Note: This section is only applicable if you are using the Piranha2 User Manual Revision 4 (0332-00493-04) or greater.

Some commands described in the Piranha2 User Manual (revision 4 or greater) are unavailable or have slightly different functionality in the P2-42-02K40-50E. See the table below for details.

Table 3: P2-42-02K40-50E Command Differences Feature P2-42-02K40-50E

roi command

Notes

Refer to section 3.10 Setting a Region of Interest for details. Refer to section 3.11 Returning Video Information for details. Refer to section 3.13 Calibrating Gains for details. Refer to section 3.14 How to Calibrate the Camera for details.

Sets a region of interest for end of line statistics only.

css command

You can sample up to 128 lines (factory setting).

cag command

Allowable range is 128 to 251DN (8 bit) or 512 to 1007DN (10 bit). Allowable range is 128 to 251DN (8 bit) or 512 to 1007DN (10 bit).

ccp command

DALSA

03-32-10065-02

P2-42-02K40-50E User's Supplement

PRELIMINARY

5

Mechanical Interface

Figure 2: P2-42-02K40-50E Mechanical Interface