Read Fiber%20Optic%20Cable.pdf text version

Fiber Optic Cable

Optical fibers from a choice of major cable manufacturers are available in several grades to manage the bandwidth requirements of today's voice, data and video networks.

Single Mode

Enhanced single mode (ESMF) features improved attenuation and optical loss performance. Now the standard offering for long haul, metro/campus applications, Fiber-to-the-home (FTTh) and premise networks. Low and Zero Water Peak (better performance across all wavelengths), Non-Zero Dispersion-Shifted (NZDF) and bendinsensitive versions are available. Used in all constructions including loose tube, tight buffer, ribbon and central tube designs.

Multimode

Multimode fiber (MM) provides superior performance for many short distance and premise networks with demanding bandwidth applications and Gigabit transmission speeds. Standard grade 62.5 FDDI to Laster-optimized 50µm versions are available. Many constructions are available to meet the needs for all outdoor and indoor applications.

Gel Free

Manufacture defines "gel free" fiber optic cables as cables with no water blocking gel between or in the buffer tubes. Cables with no water blocking gel between the buffer tubes only are described as dry. Jacket Color Chart

Link Length (m) Data Rate (Gb) Cable Type Loose Tube & Outside Plant Industrial Tray 500 300 600 1,000 550 10 10 1 1 1 Tight Buffered Grades 2, 3, 4 Tight Buffered Grades 5, 6 Tight Buffered Single Mode Jacket Color Black Orange Orange Aqua Yellow

Fiber Selection Chart

Grade Fiber Size (µ) Standards Compliance exceeds TIA/EIA-568-B.3-1 ISO 11801 0M3 TIA/EIA-568-B.3-1 ISO 11801 0M3 TIA/EIA-568-B.3-1 TIA/EIA-568-B.3-1 TIA/EIA-568-B.3-1 FDDI grade

Multimode 6 5 4 3 2 1 50/125 50/125 50/125 62.5/125 62.5/125 62.5/125 -

Non-standard jacket colors are available upon request

Fiber Sub-Unit Color Code Chart

Fiber/ Tube No. 1 2 3 4 5 6 Color Blue Orange Green Brown Slate White 4 50/125µ 850/1,300 500/500 510/500 3/1 3.5/1.25 300/2,000 600/600 85/300 5 50/125µ 850/1,300 1,500/500 2,000/500 3/1 3.5/1.25 300/2,000 1,0005/600 300/300 Fiber/ Tube No. 7 8 9 10 11 12 6 50/125µ 850/1,300 3,000/500 4,000/500 3/1 3.5/1.25 300/2,000 1,0005/600 500/300

Per EIA/TIA 598-A

Color Red Black Yellow Violet Rose Aqua Single Mode Enhanced6 1,310/1,550 .4/.3 .8/.5 --/5000 --/5000 --/10,000

Single Mode* ITU G.652.c/d

*Multiple single mode grades and constructions in stock. Call for details. Used in most current cable plants, but not recommended for future installations except as patch cordage Low water peak fiber with advantages for CWDM applications

Optical Specifications

Grade Glass Type Operating Wavelength (nm) Min. OFL Bandwidth (MHz-km)

1

2 62.5/125µ 850/1,300 200/500 220/500 3.25/1 3.5/1.25 300/2,000 300/550 35/300

4 5 6

3 62.5/125µ 850/1,300 200/500 385/500 3.25/1 3.5/1.25 300/2,000 500/1,000 35/300

Min. Laser2 Bandwidth (MHz-km) Max. Attenuation Loose Tube (dB/km) Max. Attenuation Tight Buffered (dB/km)

3

100Mb Fast Ethernet Min. Link Length (meters S/L4) 1Gb Ethernet Min. Link Length (meters S/L4) 10Gb Ethernet Min. Link Length (meters S/L4)

1 2

OFL = Overfilled Launch Effective Modal Bandwith, determined by RML or DMD performance specifications 3 Max. Attentuation for Tight Buffered, Ribbon, Micro-Loose Tube and Loose Tube Plenum Cable

S/L = Short wavelength (850nm)/Long wavelength (1310nm) >2,000 meters for engineered links Low water peak single mode suitable for CWDM use complies with ITU G.652.c/d

www.ptsupply.com [email protected]

800-238-7514

1

Fiber Optic Cable

Loose Tube

Central Strength Member Optical Fibers

Single Jacket Dielectric and Armored

Single mode (ESMF, NZDSF), Multimode, Hybrid

Flexible Buffter Tubes (2.7mm) Water Blocking Binders Strength Yarns Ripcord Armor (corrugated steel) Jacket (PE)

Applications

Loose tube cables provide versatile performance for aerial lashed, duct, and direct buried installations. These cables combine adhesive armor, flexible tubes and swellable dry water-blocking.

Specifications

Constructions Fiber Count Options

Dielectric, armored, single jacket 2 to 432 fibers in color-coded buffer tubes Preconnectorized, gel-filled core, steel central member, copper pair(s) Central, heavy duty, indoor-outdoor ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C) Single Jacket, Dielectric

Other Versions Performance Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Features and Benefits

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and outer jacket removal · Dry core swellable binders speed cable prep

Flexible Routing and Termination · Up to 20' buffer tube storage length supports multi-vendor FTTx pedestals, closures and cabinets

· Flexible buffer tubes simplify routing and splicing prep · Available with BendBright® and BendBright®XS bend-tolerant

single mode fiber Multi-purpose Installation and Use · Small diameter and light weight extend installation length

· Optional corrugated steel tape armor provides mechanical protection

and rodent resistance

2

www.ptsupply.com [email protected]

800-238-7514

Fiber Optic Cable

Loose Tube Dielectric Single Jacket

Bend Radius Diameter inch mm .42 .45 .49 .53 .56 .60 .63 .67 .74 .77 .73 10.6 11.5 12.3 13.4 14.2 15.1 16.1 16.9 18.9 19.6 18.6 Approximate Cable Weight lb/K-ft kg/km 53 63 72 82 90 99 109 126 153 167 153 79 94 107 122 134 147 162 187 228 248 228 Load inch 8 9 10 11 11 12 13 13 15 15 15 cm 21 23 25 27 28 30 32 34 38 39 37 No Load inch cm 4 5 5 5 6 6 6 7 7 8 7 11 11 12 13 14 15 16 17 19 20 19

Fiber Count 2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216 218 to 264 266 to 288 290 to 432*

No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 18

Information based on Draka specs.

Loose Tube Armored Single Jacket

Bend Radius Diameter inch mm .48 .51 .55 .59 .62 .66 .69 .73 .81 .84 .80 12.2 13.0 14.0 15.0 15.8 16.8 17.6 18.6 20.6 21.4 20.3 Approximate Cable Weight lb/K-ft kg/km 98 109 122 135 146 161 171 195 231 242 225 146 162 182 201 218 240 255 291 344 360 335 Load inch 10 10 11 12 12 13 14 15 16 17 16 cm 24 26 28 30 32 34 35 37 41 43 41 No Load inch cm 7 8 8 9 9 10 10 11 12 13 12 18 20 21 23 24 25 26 28 31 32 31

Fiber Count 2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 210 122 to 132 134 to 216 218 to 264 266 to 288 290 to 432*

No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 18

Information based on Draka specs.

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage is 8' (2.4m).

www.ptsupply.com [email protected]

800-238-7514

3

Outdoor Fiber

Loose Tube

Central Strength Member Optical Fibers

Double Jacket Dielectric, Armored, Double Armored

Single mode (ESMF, NZDSF), Multimode, Hybrid

Flexible Buffter Tubes (2.7mm) Water Blocking Binders Strength Yarns Ripcord Armor (corrugated steel)

Applications

Multi-purpose outdoor performance for aerial lashed, duct and direct buried installations.

Specifications

Jacket (PE)

Constructions Fiber Count Options

Dielectric, armored, double armored, double jacket 2 to 432 fibers in color-coded buffer tubes Preconnectorized, gel-filled core, steel central member, copper pair(s) Central, heavy duty, indoor-outdoor ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C) Double Jacket, Double Armored

Armor (corrugated steel) Jacket (PE)

Other Versions Performance Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Features and Benefits

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and outer jacket removal · Dry core swellable binders speed cable prep

Flexible Routing and Termination · Up to 20' buffer tube storage length supports multi-vendor FTTx pedestals, closures and cabinets

· Flexible buffer tubes simplify routing and splicing prep

Multi-purpose Installation and Use · Small diameter and light weight extend installation length

· Optional corrugated steel tape armor provides mechanical protection

and rodent resistance

4

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube Dielectric Double Jacket

Fiber Count 2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216 218 to 264 266 to 288 290 to 432* No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 18 Diameter inch mm .48 .51 .55 .59 .62 .66 .69 .73 .80 .83 .79 12.1 13.0 13.9 15.0 15.7 16.7 17.6 18.4 20.4 21.2 20.1 Bend Radius Approximate Cable Weight lb/K-ft kg/km 68 83 91 103 111 123 132 149 184 192 182 101 124 136 153 165 182 196 221 274 286 271 Load inch 10 10 11 12 12 13 14 15 16 17 16 cm 24 26 28 30 31 33 35 37 41 42 41 No Load inch cm 5 5 5 6 6 7 7 7 8 8 8 12 13 14 15 16 17 18 18 20 21 20

Loose Tube Armored Double Jacket

Fiber Count 2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 210 122 to 132 134 to 216 218 to 264 266 to 288 290 to 432* No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 18 Diameter inch mm .54 .57 .61 .65 .68 .72 .75 .79 .87 .90 .87 13.8 14.5 15.5 16.6 17.3 18.3 19.1 20.1 22.1 22.9 22.1 Approximate Cable Weight lb/K-ft kg/km 118 138 153 170 182 201 212 239 283 295 279 175 205 228 253 272 300 315 356 421 439 415 Load inch 11 11 12 13 14 14 15 16 17 18 17

Information based on Draka specs.

Bend Radius No Load inch cm 8 9 9 10 10 11 11 12 13 14 13 21 22 23 25 26 28 29 30 33 34 33

cm 28 29 31 33 35 37 38 40 44 46 44

Information based on Draka specs.

Loose Tube Double Armored Double Jacket

Fiber Count 2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 210 122 to 132 134 to 216 218 to 264 266 to 288 290 to 432* No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 18 Diameter inch mm .67 .70 .74 .78 .81 .85 .88 .92 1.00 1.03 1.01 17.1 17.8 18.8 19.9 20.6 21.6 22.4 23.4 25.5 26.2 25.7 Approximate Cable Weight lb/K-ft kg/km 205 232 253 274 288 315 330 359 414 429 416 306 346 377 408 428 468 492 535 616 638 619 Load inch 13 14 15 16 16 17 18 18 20 21 20

Bend Radius No Load inch cm 10 11 11 12 12 13 13 14 15 15 15 26 27 28 30 31 32 34 35 38 39 38

cm 34 36 38 40 41 43 45 47 51 52 51

Information based on Draka specs.

*Cables with fiber counts greater than 288 contain 24 fibers in a larger PBT buffer tube with 12 fiber binder groups. Rated buffer storage is 8' (2.4m).

www.ptsupply.com [email protected]

800-238-7514

5

Outdoor Fiber

Gel-Free* Dielectric and Armored Single Jacket Single Armored Double Jacket

Single mode (ESMF, NZDSF), Multimode, Hybrid

Loose Tube

Central Strength Member Optical Fibers

Flexible Buffter Tubes (2.7mm) Water Blocking Binders Strength Yarns Ripcord

Applications

Multi-purpose outdoor performance for aerial lashed, duct and direct buried installations.

Jacket (PE)

Specifications

Constructions Fiber Count Options Other Version Performance

Dielectric, armored, single and double jacket 4 to 432 fibers in color-coded buffer tubes Preconnectorized, steel central member, copper pair(s) Gel-free indoor/outdoor ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2,670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Central Strength Member Optical Fibers

Dielectric Loose Tube

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Flexible Buffter Tubes (2.7mm) Water Blocking Binders Strength Yarns Ripcord Armor (corrugated steel) Jacket (PE)

Features and Benefits

Easy Cable Entry and Preparation · Gel-free water blocked design simplifies access and reduces prep time by 15 minutes per cable end

· Adhesive bond armor greatly improves mid-entry · Ripcord speeds cable entry and outer jacket removal · Dry core swellable binders speed cable preparation

Flexible Routing and Termination · Up to 20' buffer tube storage length supports multi-vendor FTTx pedestals, closures and cabinets

Armored Loose Tube

· Flexible buffer tubes simplify routing and splicing preparation

Multi-purpose Installation and Use · Small diameter and light weight extend installations length

· Optional corrugated steel tape armor provides mechanical protections

and rodent resistance

*Power & Tel defines "gel free" fiber optic cables as cables with no water blocking gel between or in the buffer tubes. Cables with no water blocking gel between the buffer tubes only are described as dry.

6

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube Dielectric Gel-Free Single Jacket

Fiber Count 4 to 60 72 84 96 108 120 132 144 to 216 228 to 264 276 to 288 290 to 432 No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 36 Diameter inch mm .42 .45 .49 .53 .56 .60 .63 .67 .74 .77 .87 10.6 11.5 12.3 13.4 14.2 15.1 16.1 16.9 18.9 19.6 22.1 Approximate Cable Weight lb/K-ft kg/km 47 56 64 73 80 87 96 105 128 139 187 71 84 95 108 119 130 143 156 190 207 278 Load inch 8 9 10 11 11 12 13 13 15 15 18 cm 21 23 25 27 28 30 32 34 38 39 44 Bend Radius No Load inch cm 4 5 5 5 6 6 6 7 7 8 9 11 11 12 13 14 15 16 17 19 20 22

Information based on Draka specs.

Loose Tube Armored Gel-Free Single Jacket

Fiber Count 4 to 60 72 84 96 108 120 132 144 to 216 228 to 264 276 to 288 290 to 432 No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 36 Diameter inch mm .48 .51 .55 .59 .62 .66 .69 .73 .81 .84 .95 12.2 13.0 14.0 15.0 15.8 16.8 17.6 18.6 20.6 21.4 24.1 Approximate Cable Weight lb/K-ft kg/km 93 102 114 126 136 150 159 175 206 214 254 138 152 170 187 203 223 236 260 306 319 378 Load inch 10 10 11 12 12 13 14 15 16 17 19

Bend Radius No Load inch cm 7 8 8 9 9 10 10 11 12 13 10 18 20 21 23 24 25 26 28 31 32 24

cm 24 26 28 30 32 34 35 37 41 43 48

Information based on Draka specs.

Loose Tube Gel-Free Single Armored Double Jacket

Fiber Count 4 to 60 72 84 96 108 120 132 144 to 216 228 to 264 276 to 288 290 to 432 No. Buffer Tubes 5 6 7 8 9 10 11 18 22 24 36 Diameter inch mm .54 .57 .61 .65 .68 .72 .75 .79 .87 .90 1 13.8 14.5 15.5 16.6 17.3 18.3 19.1 20.1 22.1 22.9 25.4 Approximate Cable Weight lb/K-ft kg/km 112 131 145 160 172 190 199 218 257 267 291 167 195 216 239 257 283 296 325 383 398 433 Load inch 11 11 12 13 14 14 15 16 17 18 20

Bend Radius No Load inch cm 8 9 9 10 10 11 11 12 13 14 10 21 22 23 25 26 28 29 30 33 34 26

cm 28 29 31 33 35 37 38 40 44 46 51

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

7

Outdoor Fiber

Loose Tube

Optical Fibers Integrated Messenger (.25" EHS Steel) Flexible Buffter Tubes (3mm) Ripcord Water Blocking Binders Jacket (PE)

Figure-8 Self-Supporting Non-Armored and Armored

Single mode (ESMF, NZDSF), Multimode, Hybrid

Applications

One-step aerial deployment for up to 600' with integrated steel messenger. Installation uses existing Figure-8 hardware and methods.

Specifications

Constructions Fiber Count Options Performance

Non-armored and armored with 1/4" integrated messenger 2 to 216 fibers in color-coded buffer tubes Preconnectorized, gel-filled core ANSI/ICEA, IEC, RDUP, Telcordia GR-20 2,600 lbf (11,500N) Heavy Load: 350' to 400' (107m to 122m) Medium Load: 550' to 600' (168m to 183m) Light Load: 600' (183m) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Optical Fibers Integrated Messenger (.25" EHS Steel) Flexible Buffter Tubes (3mm) Ripcord Water Blocking Binders Armor Jacket (PE)

Non-Armored Loose Tube

Maximum Messenger Load Maximum Span Distances Shipping and Storage Installation Operation

Features and Benefits

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and outer jacket removal · Swellable binders speed cable preparation

Flexible Routing and Termination · Flexible buffer tubes simplify routing and splicing preparation

Armored Loose Tube

8

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube Non-Armored F-8 Self-Supporting

Bend Radius Diameter inch mm .51 .54 .59 .63 .66 .70 .74 12.9 13.8 15.0 15.9 16.9 17.8 18.8 Height inch .96 .99 1.04 1.07 1.12 1.16 1.19 mm 24.3 25.3 26.5 27.3 28.4 29.4 30.3 Approximate Cable Weight lb/K-ft kg/km 225 235 247 257 269 281 304 335 350 367 383 400 418 452 Load inch 10 11 12 13 13 14 15 cm 26 28 30 32 34 35 37 No Load inch cm 5 6 6 7 7 7 8 13 14 15 16 17 18 19

Fiber Count 2 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216

Information based on Draka specs.

Loose Tube Armored F-8 Self-Supporting

Bend Radius Diameter inch mm .56 .59 .64 .67 .72 .76 .79 14.1 15.1 16.3 17.1 18.2 19.2 20.1 Height inch 1.02 1.06 1.11 1.14 1.18 1.22 1.26 mm 26.0 27.0 28.2 29.0 30.1 31.1 32.0 Approximate Cable Weight lb/K-ft kg/km 279 293 310 323 338 354 381 416 436 462 480 503 527 567 Load inch 11 12 13 14 14 15 16 cm 29 31 33 35 37 39 42 No Load inch cm 9 9 10 10 11 12 12 21 23 25 26 28 29 30

Fiber Count 2 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

9

Outdoor Fiber

Loose Tube

ADSS Self-Supporting Short Span Single Jacket

Single mode (ESMF, NZDSF), Multimode, Hybrid

Optical Fibers

Flexible Buffter Tubes (2.7mm) Water Blocking Binders Strength Yarns Ripcord

Applications

Self-supporting aerial deployment for communications and transmission space for up to 1,000'.

Specifications

Jacket (PE)

Constructions Fiber Count Options Performance Minimum Bend Radius Shipping and Storage Installation Operation

All-dielectric round, single jacket 2 to 144 fibers in color-coded buffer tubes Single or dual jackets (see page 12), matching pole attachment hardware IEEE 1222 ANSI/ICEA, IEC, RDUP, Telcordia GR-20 With Load: 20x cable diameter No Load: 10x cable diameter -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Features and Benefits

Easy Cable Entry and Preparation · Flexible buffer tubes and single jacket option enhance mid-entry

· Ripcord speeds cable entry and outer jacket removal · Swellable binders speed cable preparation

Flexible Routing and Termination · Flexible buffer tubes simplify routing and splicing preparation Versatile Installation and Use · Tailored designs span distances up to 1,000' without interrupting power

· Easy mid-entry is ideal for FTTx distribution applications

10

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube ADSS Self-Supporting Short Span Single Jacket

NESC Light, 1% Sag Fiber Count 2 to 72 200 300 400 500 600 700 800 900 1,000 74 to 96 200 300 400 500 600 700 800 900 98 to 144 200 300 400 500 600 61 91 122 152 183 .74 .74 .74 .74 .75 18.7 18.7 18.8 18.9 19.0 141 141 143 145 147 210 210 213 216 219 .74 .74 .74 .75 18.7 18.7 18.8 19.0 141 142 144 147 210 212 215 219 .74 .74 18.7 18.9 142 145 211 216 61 91 122 152 183 213 244 274 .57 .57 .57 .57 .58 .58 .59 .59 14.4 14.4 14.4 14.5 14.6 14.8 14.9 15.0 94 94 94 95 97 98 100 102 140 140 140 142 144 146 149 151 .57 .57 .57 .58 .58 .59 14.4 14.4 14.6 14.7 14.8 15.5 94 94 96 97 99 102 140 140 142 145 148 151 .57 .58 .59 14.4 14.6 14.9 94 97 100 140 144 149 61 91 122 152 183 213 244 274 305 .48 .48 .48 .48 .49 .49 .50 .50 .51 12.3 12.3 12.3 12.3 12.4 12.5 12.6 12.8 12.9 74 74 74 74 75 76 78 79 80 110 110 110 110 111 114 115 118 120 .48 .48 .49 .49 .50 .50 .51 12.3 12.3 12.3 12.5 12.6 12.8 13.0 74 74 74 76 78 80 81 110 110 110 113 115 119 121 .48 .49 .50 .51 12.3 12.4 12.7 13.0 74 75 78 81 110 112 116 121 Span meter Diameter inch mm Weight lb/K-ft kg/km NESC Medium, 1% Sag Diameter inch mm Weight lb/K-ft kg/km NESC Heavy, 1% Sag Diameter inch mm Weight lb/K-ft kg/km

feet

Information based on Draka specs.

Contact your Power & Tel representative for information about designs with alternative span requirements or cable diameters. Cable diameters and weights may vary depending on specific span requirements.

www.ptsupply.com [email protected]

800-238-7514

11

Outdoor Fiber

Loose Tube

ADSS Self-Supporting Short Span Double Jacket

Single mode (ESMF, NZDSF), Multimode, Hybrid

Optical Fibers

Flexible Buffter Tubes (3 mm) Water Blocking Binders Ripcord Jacket (PE) Strength Yarns

Applications

Self-supporting aerial deployment for communications and transmission space for up to 1,000'.

Specifications

Ripcord

Constructions Fiber Count Options Performance Minimum Bend Radius Shipping and Storage Installation Operation

All-dielectric round, double jacket 2 to 144 fibers in color-coded buffer tubes Single (see page 10) or dual jackets, matching pole attachment hardware IEEE 1222 ANSI/ICEA, IEC, RDUP, Telcordia GR-20 With Load: 20x cable diameter No Load: 10x cable diameter -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Jacket (PE)

Features and Benefits

Easy Cable Entry and Preparation · Flexible buffer tubes and single jacket option enhance mid-entry

· Ripcord speeds cable entry and outer jacket removal · Swellable binders speed cable preparation

Flexible Routing and Termination · Flexible buffer tubes simplify routing and splicing preparation Versatile Installation and Use · Tailored designs span distances up to 1,000' without interrupting power

· Easy mid-entry is ideal for FTTx distribution applications

12

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube ADSS Self-Supporting Short Span Double jacket

NESC Light, 1% Sag Fiber Count 2 to 72 200 300 400 500 600 700 800 900 74 to 96 200 300 400 500 600 700 800 900 98 to 144 200 300 400 500 600 700 800 61 91 122 152 183 213 244 .80 .80 .80 .81 .81 .82 .82 20.2 20.3 20.4 20.5 20.6 20.8 20.9 173 174 176 178 180 183 186 257 259 262 265 268 272 277 .80 .80 .81 .81 .82 .82 20.2 20.3 20.5 20.6 20.8 20.9 173 175 177 180 183 186 257 260 263 268 272 277 .80 .81 .82 .82 20.3 20.5 20.7 20.9 174 178 182 186 259 265 271 277 61 91 122 152 183 213 244 274 .63 .63 .63 .64 .64 .65 .65 .66 16.0 16.0 16.0 16.2 16.3 16.4 16.5 16.7 119 119 119 121 123 125 126 129 177 177 177 180 183 186 188 192 .63 .63 .64 .64 .65 .65 16.0 16.0 16.2 16.3 16.4 16.6 119 119 121 123 125 128 177 177 180 184 187 191 .63 .64 .65 .66 16.0 16.2 16.4 16.7 119 122 125 129 177 182 187 192 61 91 122 152 183 213 244 274 .55 .55 .55 .55 .55 .56 .56 .57 13.8 13.8 13.8 13.9 14.0 14.2 14.3 14.4 95 95 95 96 98 99 101 102 141 141 141 143 145 148 150 152 .55 .55 .55 .56 .56 .57 13.8 13.8 14.0 14.1 14.2 14.4 95 95 97 98 100 102 141 141 144 146 149 153 .55 .55 .56 .57 13.8 14.0 14.3 14.5 95 98 101 104 141 145 150 155 Span meter Diameter inch mm Weight lb/K-ft kg/km NESC Medium, 1% Sag Diameter inch mm Weight lb/K-ft kg/km NESC Heavy, 1% Sag Diameter inch mm Weight lb/K-ft kg/km

feet

Information based on Draka specs.

Contact your Power & Tel representative for information about designs with alternative span requirements or cable diameters. Cable diameters and weights may vary depending on specific span requirements.

www.ptsupply.com [email protected]

800-238-7514

13

Outdoor Fiber

Loose Tube

ADSS Self-Supporting Long Span Single Jacket

Single mode (ESMF, NZDSF), Multimode, Hybrid

Optical Fibers

Applications

Water Blocking Binders Strength Yarns Ripcord

Self-supporting aerial deployment for communications and transmission space for up to 2,500'.

Specifications

Jacket (PE)

Constructions Fiber Count Options Performance Minimum Bend Radius Shipping and Storage Installation Operation

All-dielectric round, single jacket 2 to 72 fibers in color-coded buffer tubes Track resistant (>4kV space potential) IEEE 1222 ANSI/ICEA, IEC, RDUP, Telcordia GR-20 With Load: 20x cable diameter No Load: 10x cable diameter -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Features and Benefits

Easy Cable Entry and Preparation · Ripcord speeds cable entry and outer jacket removal

· Swellable binders speed cable preparation

Proven Long Span Installation and Use · Tailored designs span distances up to 2,500' without interrupting power

· Matching pole attachment hardware (dead-ends, suspension clamps)

14

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube ADSS Self-Supporting Long Span Single Jacket

NESC Light, 1% Sag Fiber Count 2 to 72 200 300 400 500 600 700 800 900 1,000 61 91 122 152 183 213 244 274 305 .44 .45 .47 11.3 11.5 11.8 70 72 75 103 108 112 .44 .44 .45 .46 .46 .47 11.3 11.3 11.4 11.6 11.7 12.0 70 70 71 73 75 77 103 103 106 109 111 115 .44 .44 .44 .45 .45 .46 .46 .47 .47 11.3 11.3 11.3 11.4 11.5 11.6 11.7 11.9 12.0 70 70 70 71 72 73 75 76 77 103 103 103 105 107 109 111 113 115 Span meter Diameter inch mm Weight lb/K-ft kg/km NESC Medium, 1% Sag Diameter inch mm Weight lb/K-ft kg/km NESC Heavy, 1% Sag Diameter inch mm Weight lb/K-ft kg/km

feet

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

15

Outdoor Fiber

Loose Tube

ADSS Self-Supporting Long Span Double Jacket

Single mode (ESMF, NZDSF), Multimode, Hybrid

Optical Fibers

Buffer Tubes Water Blocking (Swellable) Binders Ripcord Inner Jacket (some designs) Aramid Strength Yarns

Applications

Self-supporting aerial deployment for communications and transmission space for up to 2,500'.

Specifications

Constructions Fiber Count Options Performance Minimum Bend Radius Shipping and Storage Installation Operation

All-dielectric round, double jacket 2 to 288 fibers in color-coded buffer tubes Track resistant (>4kV space potential) IEEE 1222 ANSI/ICEA, IEC, RDUP, Telcordia GR-20 With Load: 20x cable diameter No Load: 10x cable diameter -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Jacket (PE)

Features and Benefits

Easy Cable Entry and Preparation · Ripcord speeds cable entry and outer jacket removal

· Swellable binders speed cable preparation

Proven Long Span Installation and Use · Tailored designs span distances up to 2,500' without interrupting power

· Higher count designs utilize 24 fibers per tube to reduce environmental load · Matching pole attachment hardware (dead-ends, suspension clamps)

16

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube ADSS Self-Supporting Long Span Double Jacket

NESC Light, 1% Sag Fiber Count 2 to 72 200 400 600 800 1,000 1,200 1,600 2,000 74 to 144 200 400 600 800 1,000 1,200 1,600 2,000 146 to 216 200 400 600 800 1,000 1,200 1,600 2,000 218 to 288 200 400 600 800 1,000 1,200 1,600 2,000 61 122 183 244 305 366 488 610 .83 .85 .87 .90 .93 .95 21.1 21.5 22.2 22.9 23.5 24.2 207 216 229 244 257 272 308 321 340 363 382 404 .83 .84 .85 .87 .89 .91 .96 21.0 21.3 21.6 22.2 22.6 23.2 24.3 205 211 218 229 238 249 274 305 313 324 340 354 371 408 .83 .83 .84 .86 .88 .90 .94 .97 21.0 21.2 21.5 21.7 22.3 22.8 23.8 24.7 205 209 215 220 232 242 264 284 305 311 319 327 345 360 393 422 61 122 183 244 305 366 488 610 .70 .72 .75 .77 .80 .83 17.8 18.3 19.0 19.6 20.4 21.0 157 165 178 189 202 215 234 245 265 281 301 319 .70 .71 .72 .73 .76 .78 .83 .87 17.8 18.0 18.3 18.6 19.3 19.9 21.0 22.0 156 160 166 171 182 193 215 235 233 238 247 254 272 288 319 349 .70 .70 .72 .73 .74 .76 .80 .84 17.8 17.9 18.2 18.4 18.7 19.4 20.4 21.3 156 159 163 168 172 184 202 220 233 236 243 250 255 274 301 327 61 122 183 244 305 366 488 610 .57 .59 .61 .65 .68 .71 .77 14.6 15.1 15.5 16.5 17.3 17.9 19.6 114 120 127 141 154 164 192 169 179 188 210 229 244 286 .57 .58 .59 .60 .62 .65 .70 .74 14.6 14.8 15.1 15.4 15.8 16.5 17.8 18.8 114 116 120 124 130 141 161 179 169 172 179 184 193 210 240 267 .57 .58 .59 .60 .60 .62 .67 .71 14.6 14.6 14.9 15.1 15.4 15.7 16.9 17.9 114 114 117 121 124 129 147 164 169 170 175 180 184 192 219 244 61 122 183 244 305 366 488 610 .53 .55 .57 .60 .64 .67 13.4 13.9 14.4 15.3 16.2 17.0 97 103 109 122 135 147 144 153 162 182 201 218 .52 .53 .55 .56 .57 .60 .65 .69 13.3 13.5 13.9 14.2 14.5 15.3 16.5 17.6 95 98 103 106 111 122 140 157 142 146 153 158 165 182 208 234 .52 .53 .54 .55 .56 .57 .62 .65 13.3 13.4 13.6 13.9 14.1 14.4 15.7 16.6 95 97 99 103 106 110 127 141 142 144 148 153 157 163 189 210 Span meter Diameter inch mm Weight lb/K-ft kg/km NESC Medium, 1% Sag Diameter inch mm Weight lb/K-ft kg/km NESC Heavy, 1% Sag Diameter inch mm Weight lb/K-ft kg/km

feet

Information based on Draka specs.

Contact your Power & Tel representative for information about designs with alternative span requirements or cable diameters. Cable diameters and weights may vary depending on specific span requirements.

www.ptsupply.com [email protected]

800-238-7514

17

Outdoor Fiber Outdoor Fiber

Loose Tube

Dielectric and Toneable Flat Drop

Single mode, Multimode, Hybrid

Optical Fibers

Central Buffer Tube (gel-filled) Strength Members (dielectric) Water Blocking Strength Yarns Ripcord

Applications

Multi-purpose FTTx - aerial self-support, direct buried and duct

Specifications

Constructions Fiber Count Options Performance

Flat profile, dielectric and toneable 1 to 12 fibers Packaging: portable box/spool/bulk reel Preconnectorized: 1 or 2 ends ANSI/ICEA, IEC, RDUP, Telcordia GR-20 drop cable 1-6 Fiber: 300 lbf (1,335N) 7-12 Fiber: 600 lbf (2,670N) 1-6 Fiber: 90 lbf (400N) 7-12 Fiber: 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C) Heavy ­ 150' (46m) Medium ­ 210' (64m) Light ­305' (93m) Heavy ­ 140' (43m) Medium ­ 205' (62m) Light ­285' (87m)

Optical Fibers Jacket (PE)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation Max. Span with NESC Loading Conditions Max. Span with NESC Loading Conditions

Dielectric Flat Drop

Dielectric

Central Buffer Tube (gel-filled)

Toneable

Strength Members (dielectric) Water Blocking Strength Yarns

Features and Benefits

Ripcord Toning Wire (optional 24 AWG) Jacket (PE)

Easy Cable Entry and Preparation · Flat profile utilizes ecomonical wedge clamps

· Compatibility with existing installation hardware and methods · Ripcord speeds cable entry and jacket removal · Toning wire enables underground location (toneable option)

Flexible Routing and Termination · Flexible buffer tube simplifies routing and splicing

· Preconnectorized option for plug and play connectivity

Multi-Purpose Installation and Use · Suitable for self-support aerial, duct and buried Toneable Flat Drop

· Portable box and spool packaging simplify widespread deployment

18

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube Dielectric Flat Drop

Bend Radius Buffer Tube inch mm .075 .118 1.9 3.0 Width inch .31 .41 mm 8.0 10.4 Height inch mm .15 .20 3.9 5.0 Cable Weight lb/K-ft kg/km 22 34 33 51 Load inch 4.6 6.0 No Load inch cm 3.1 4.1 8 10

Fiber Count 1 to 6 7 to 12

cm 12 15

Information based on Draka specs.

Loose Tube Toneable Flat Drop

Bend Radius Buffer Tube inch mm .075 .118 1.9 3.0 Width inch .42 .51 mm 10.7 13.0 Height inch mm .15 .20 3.9 5.0 Cable Weight lb/K-ft kg/km 25 38 37 56 Load inch 4.6 6.0 No Load inch cm 3.1 4.0 8 10

Fiber Count 1 to 6 7 to 12

cm 12 15

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

19

Outdoor Fiber Outdoor Fiber

Figure-8 Integrated Messenger Drop

Single mode, Multimode, Hybrid

Loose Tube

Optical Fibers Central Buffer Tube (gel-filled) Integrated Messenger Strength Members (dielectric) Water Blocking Strength Yarns Ripcord

Applications

Multi-purpose FTTx - aerial self-support, direct buried and duct.

Specifications

Constructions Fiber Count Options Performance

Integrated messenger, non-armored 2 to 6 fibers Packaging: portable box/spool/bulk reel Preconnectorized: 1 or 2 ends ANSI/ICEA, IEC, RDUP, Telcordia GR-20 drop cable 300 lbf (1,335N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C) Heavy ­ 150' (46m) Medium ­ 265' (80m) Light ­410' (125m) Heavy ­ 62 lbs. (275N) Medium ­ 109 lbs. (485N) Light ­169 lbs. (705N)

Jacket (PE)

Maximum Installation Load Shipping and Storage Installation Operation Max. Span with NESC Loading Conditions Max. Installation Tension with NESC Loading Conditions

Features and Benefits

Easy Cable Entry and Preparation · Compatible with existing Figure-8 installation and hardware methods

· Tear-away messenger simplifies grounding · Ripcord speeds cable entry and jacket removal · Toneable messenger enables underground locating

Flexible Routing and Termination · Flexible buffer tube simplifies routing and splicing

· Preconnectorized option for plug and play connectivity

Multi-Purpose Installation and Use · Suitable for self-support aerial, duct and buried

· Portable box and spool packaging simplify widespread deployment

20

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube F-8 Integrated Messenger Drop

Bend Radius Buffer Tube inch mm .075 1.9 Diameter inch mm .16 4.1 Height inch mm .34 8.8 Approximate Cable Weight lb/K-ft kg/km 33 49 Load inch 6 cm 15 No Load inch cm 6 15

Fiber Count 1 to 6

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

21

Outdoor Fiber

Loose Tube

Dielectric and Toneable Flat Ribbon Drop

Single mode, Multimode, Hybrid

Optical Fibers

Central Buffer Tube (gel-filled) Strength Members (dielectric) Water Blocking Strength Yarns Ripcord

Applications

Multi-purpose FTTx - aerial self-support, direct buried and duct.

Specifications

Constructions Fiber Count Options Performance

Flat profile, dielectric and toneable 4 or 6 fibers (single ribbon) Packaging: spool/bulk reel Preconnectorized: 1 or 2 ends ANSI/ICEA, IEC, RDUP, Telcordia GR-20 drop cable 600 lbf (2,670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C) Heavy ­ 150' (46m) Medium ­ 210' (64m) Light ­305' (93m) Heavy ­ 140' (43m) Medium ­ 205' (62m) Light ­285' (87m) Dielectric

Central Buffer Tube (gel-filled) Optical Fibers Jacket (PE)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation Max. Span with NESC Loading Conditions Max. Span with NESC Loading Conditions

Dielectric Flat Ribbon Drop

Toneable

Strength Members (dielectric) Water Blocking Strength Yarns Ripcord Toning Wire (optional 24 AWG) Jacket (PE)

Features and Benefits

Easy Cable Entry and Preparation · Flat profile design uses economical wedge clamps

· Compatible with existing hardware and methods · Ripcord speeds cable entry and jacket removal · Optional toning wire enables underground locating

Multi-purpose Installation and Use · Spool and bulk reel packaging simplify deployment

Toneable Flat Ribbon Drop

22

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Loose Tube Dielectric Flat Ribbon Drop

Bend Radius Buffer Tube inch mm .118 3 Width inch .41 mm 10.4 Height inch mm .20 5 Cable Weight lb/K-ft kg/km 34 51 Load inch 6 No Load inch cm 4 10

Fiber Count 4 or 6

cm 15

Information based on Draka specs.

Loose Tube Toneable Flat Ribbon Drop

Bend Radius Buffer Tube inch mm .118 3 Width inch .51 mm 13 Height inch mm .2 5 Cable Weight lb/K-ft kg/km 38 56 Load inch 6 No Load inch cm 4 10

Fiber Count 4 or 6

cm 15

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

23

Outdoor Fiber

Central Tube

Single mode (ESMF)

Dielectric and Armored Ribbon

Applications

Optical Fibers (12) Fiber Ribbons Flexible Core Tube (gel filled) Water Blocking (swellable tape) Ripcord Strength Yarns Strength Elements (dielectric) Jacket (PE)

Multi-purpose Outdoor - aerial lashed, duct, direct buried and high counts/high density/mass splicing.

Specifications

Constructions Fiber Count Options Performance

Dielectric, armored 12 to 432 fibers in multi-fiber ribbons Preconnectorized/standard tube design ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2,670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

216-Fiber Dielectric Ribbon

Features and Benefits

Optical Fibers (24) Fiber Ribbons Flexible Core Tube (gel filled) Water Blocking (swellable tape) Ripcord Strength Yarns Corrugated Armor Jacket (PE)

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and jacket removal · Compatible with ribbon tools and methods (heat stripping, mechanical

peel and mass splicing) Multi-purpose Installation and Use · Spool and bulk reel packaging simplify deployment

432-Fiber Armored Ribbon

24

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Central Tube Dielectric Ribbon

Bend Radius Diameter inch mm .55 .61 .69 .77 13.9 15.5 17.5 19.6 Approximate Cable Weight lb/K-ft kg/km 97 120 163 204 144 179 243 304 Load inch 11 12 14 15 cm 28 31 35 39 No Load inch cm 6 6 7 8 14 16 18 20

Fiber Count 12 to 72 84 to 144 156 to 216 240 to 432

Information based on Draka specs.

Central Tube Armored Ribbon

Bend Radius Diameter inch mm .57 .62 .72 .86 14.4 15.6 18.2 21.8 Approximate Cable Weight lb/K-ft kg/km 138 174 222 292 205 260 330 434 Load inch 12 13 15 17 cm 29 31 36 44 No Load inch cm 9 9 11 13 22 23 27 33

Fiber Count 12 to 72 84 to 144 156 to 216 240 to 432

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

25

Outdoor Fiber

Central Tube

Single mode (ESMF)

Optical Fibers Flexible Stranded Tubes (gel filled) Binders Water Blocking Tape Ripcord Strength Yarns

High Count Ribbon Dielectric and Armored

Applications

Multi-purpose Outdoor - aerial lashed, duct, direct buried and high counts/ high density/mass splicing.

Jacket (PE)

Specifications

Constructions Fiber Count Options Performance

Dielectric, armored 288 to 864 in 12-fiber ribbons Preconnectorized/central tube design ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2,670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Optical Fibers Flexible Stranded Tubes (gel filled) Binders Water Blocking Tape Ripcord Strength Yarns Armor (corrugated steel) Jacket (PE)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Dielectric Loose Tube Ribbon

Features and Benefits

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and jacket removal · Compatible with ribbon tools and methods (heat stripping, mechanical

peel and mass splicing) Simplified Fiber Management and Access · Color-coded buffer tubes segregate ribbon groups

· Easy to access individual tubes, ribbons and fibers

Armored Loose Tube Ribbon

26

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Central Tube Dielectric High Count Ribbon

Bend Radius Diameter inch mm .88 1.04 22.4 26.4 Approximate Cable Weight lb/K-ft kg/km 237 322 343 479 Load inch 18 21 cm 45 53 No Load inch cm 9 11 22 27

Fiber Count 288 to 432 576 to 864

Information based on Draka specs.

Central Tube Armored High Count Ribbon

Bend Radius Diameter inch mm .94 1.16 23.9 29.5 Approximate Cable Weight lb/K-ft kg/km 317 430 472 640 Load inch 19 23 cm 48 58 No Load inch cm 14 17 36 44

Fiber Count 288 to 432 576 to 864

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

27

Outdoor Fiber

Central Tube

Single mode (ESMF)

Gel-Free* Ribbon Dielectric and Armored

Applications

Optical Fibers (12) Fiber Ribbons Flexible Core Tube (gel filled) Water Blocking (swellable tape) Ripcord Strength Yarns Strength Elements (dielectric) Jacket (PE)

Multi-purpose Outdoor - aerial lashed, duct and direct buried.

Specifications

Constructions Fiber Count Options Performance

Dielectric, armored 12 to 432 fibers in multi-fiber ribbons Preconnectorized ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2,670N) 180 lbf (800N) -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Optical Fibers (24) Fiber Ribbons Flexible Core Tube (gel filled) Water Blocking (swellable tape) Ripcord Strength Yarns Corrugated Armor Jacket (PE)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

216-Fiber Dielectric Ribbon

Features and Benefits

Easy Cable Entry and Preparation · Gel-free design simplifies access and reduces prep time

· Adhesive bond armor greatly improves mid-entry · Ripcord speeds cable entry and jacket removal · Compatible with ribbon equipment and procedures (heat strip and mass

splicing) Multi-purpose Installation and Use · Suitable for aerial, lashed, duct and buried

· Optional corrugated steel tape armor provides mechanical protection and

rodent resistance

432-Fiber Armored Ribbon *Power & Tel defines "gel free" fiber optic cables as cables with no water blocking gel between or in the buffer tubes. Cables with no water blocking gel between the buffer tubes only are described as dry.

28

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Central Tube Dielectric Gel-Free Ribbon

Bend Radius Diameter inch mm .55 .66 .76 .79 14.0 16.8 19.3 20.1 Approximate Cable Weight lb/K-ft kg/km 82 118 147 154 122 176 219 230 Load inch 11 13 15 16 cm 28 34 39 40 No Load inch cm 6 7 8 8 14 17 19 20

Fiber Count 12 to 48 60 to 144 156 to 216 240 to 432

Information based on Draka specs.

Central Tube Armored Gel-Free Ribbon

Bend Radius Diameter inch mm .57 .67 .77 .85 14.4 16.9 19.5 21.6 Approximate Cable Weight lb/K-ft kg/km 124 153 191 218 184 228 284 325 Load inch 12 13 15 17 cm 29 34 39 43 No Load inch cm 9 10 12 9 22 25 29 22

Fiber Count 12 to 48 60 to 144 156 to 216 240 to 432

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

29

Outdoor Fiber

Central Tube

Dielectric and Armored MicroUnitube

Single mode (ESMF), Multimode, Hyrbid

Color-Coded Binders

Optical Fibers (12 fiber bundles) Central Core Tube (gel-filled) Strength Elements (steel) Armor (corrugated steel)

Applications

Multi-purpose Outdoor - aerial lashed, duct and direct buried.

Specifications

Constructions Fiber Count Options Performance

Dielectric, armored 2 to 24 fibers in fiber bundles separated by colorcoded binder threads Preconnectorized ANSI/ICEA, IEC, RDUP, Telcordia GR-20 600 lbf (2,670N) - Armored 300 lbf (1,335N) - Dielectric 180 lbf (800N) - Armored 90 lbf (400N) - Dielectric -40°F to 167°F (-40°C to 75°C) -22°F to 140°F (-30°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Ripcords (armored) Jacket (PE)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Armored MicroUnitube

Features and Benefits

Easy Cable Entry and Preparation · Adhesive bond armor greatly improves mid-entry

· Ripcord speeds cable entry and outer jacket removal · Single core tube allows quick access to fibers

Multi-purpose Installation and Use · Small diameter and light weight extend reel and installation lengths

· Corrugated steel tape armor provides mechanical protection and

rodent resistance (armored version)

30

www.ptsupply.com [email protected]

800-238-7514

Outdoor Fiber

Central Tube Dielectric MicroUnitube

Bend Radius Diameter inch mm .35 8.8 Cable Weight lb/K-ft kg/km 40 60 Load inch 7 cm 18 No Load inch cm 4 9

Fiber Count 2 to 12

Information based on Draka specs.

Central Tube Armored MicroUnitube

Bend Radius Diameter inch mm .41 10.3 Approximate Cable Weight lb/K-ft kg/km 77 114 Load inch 8 cm 21 No Load inch cm 6 15

Fiber Count 2 to 24

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

31

Indoor/Outdoor Fiber

Tight Buffer

Optical Fibers

Distribution Riser and Plenum

Color-Coded Tight Buffer Coating (900µm)

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Applications

Suitable for both indoor and outdoor use, ideal for interbuilding and transition applications.

Aramid Strength Yarns

Specifications

Constructions Fiber Count Options

900µm tight buffered color-coded fibers - dielectric and interlock armor 2 to 144 fibers (cables > 12 fibers are unitized) Indoor, LSZH and specialty versions (mining, remote broadcast; tactical deployment; preconnectorized) TIA/EIA-568B, ICEA 83-596, Telcordia GR-409, IEEE383 2-12 Fiber: 300 lbs (1,335N) 18-144 Fiber: 600 lbs (2,700N) 2-12 Fiber: 90 lbs (400.5N) 18-144 Fiber: 180 lbs (810N) 2-12 Fiber: 150 lbs (666N) 18-60 Fiber: 400 lbs (1,800N) 72-144 Fiber: 600 lbs (4,445N) 2-12 Fiber: 45 lbs (199.8N) 18-60 Fiber: 120 lbs (540N) 72-144 Fiber: 180 lbs (810N) -40°F to 176°F (-40°C to 80°C) 32°F to 122°F (0°C to 50°C) -40°F to 158°F (-40°C to 70°C)

Flame-Rated Jacket

Performance *Max. Installation Load (Riser) Max. Operation Load (Riser) *Max. Installation Load (Plenum) Max. Operation Load (Plenum) Shipping and Storage Installation Operation

*Pull Strength

6-Fiber Cable

Central Strength Member Optical Fibers Color-Coded Tight Buffer Coating (900µm) Aramid Strength Yarns 6 fiber sub-unit (18 - 36 fibers) 12 fiber sub-unit (> 36 - 144 fibers) Flame-Rated Jacket

Features and Benefits

Easy Cable Installation and Termination · 900µm tight buffered fibers can be directly terminated

· Flexible small diameter cables simplify pulling and placement · Color-coded fibers and numbered sub-units simplify identification · Optional interlock armor provides robust protection and one-step installation

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), plenum (OFNP/FT-6) and LSZH

36-Fiber Cable

· A single cable design can support all structured cabling applications

32

www.ptsupply.com [email protected]

800-238-7514

Indoor/Outdoor Fiber

Tight Buffer Distribution Riser (OFNR, FT-4 Rated)

Bend Radius Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

Fibers per Unit

2 4 6 8 12 18 24 36 48 60 72 84 96 108 120 132 144

2 4 6 8 12 6 6 6 12 12 12 12 12 12 12 12 12

.19 .22 .24 .24 .28 .56 .56 .66 .66 .74 .80 .85 .95 1.02 1.02 1.02 1.02

4.8 5.6 6.0 7.0 14.2 14.2 16.8 16.8 16.8 18.8 20.3 21.7 24.2 25.9 25.9 25.9 25.9

15 19 21 23 30 94 94 99 134 168 198 231 287 341 341 341 341

22 28 31 34 45 140 140 148 200 250 295 345 428 508 508 508 508

4 4 5 5 6 11 11 13 13 15 16 17 19 20 20 20 20

10 11 12 12 18 28 33 33 33 38 41 43 48 52 52 52 52

2 2 2 2 3 6 6 7 7 7 8 9 10 10 10 10 10

5 6 6 6 7 14 17 17 17 19 20 22 24 26 26 26 26

Information based on Draka specs.

Tight Buffer Distribution Plenum (OFNP, FT-6 Rated)

Bend Radius Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

Fibers per Unit

2 4 6 8 12 18 24 36 48 60 72 96 144

2 4 6 8 12 6 6 6 12 12 12 12 12

.18 .18 .19 .21 .24 .44 .44 .55 .56 .63 .69 .84 .98

4.5 4.6 5.0 5.2 6.1 11.2 11.2 13.8 14.3 16.0 17.5 21.3 24.9

9 14 15 18 22 86 78 131 140 172 209 345 433

13 21 22 27 33 128 117 196 209 257 312 514 646

4 4 4 4 5 9 9 11 11 13 14 17 20

9 9 10 10 12 22 22 28 29 32 35 43 50

2 2 2 2 2 4 4 5 6 6 7 8 10

5 5 5 5 6 11 11 14 14 16 18 21 24

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

33

Indoor/Outdoor Fiber

Loose Tube Riser

Dielectric Single, Double Jacket Armored Double Jacket

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Optical Fibers

Flexible Buffter Tubes Water Blocking Binders Ripcord Strength Yarns Flame-Rated Jacket

Applications

Suitable for a combination of indoor flame-rated spaces and outdoor aerial lashed, duct and direct buried environments. By enabling placement virtually anywhere in a network, installers can bypass traditional transition points required in many installations and go directly from outside plant to riser shaft.

Specifications

Constructions Fiber Count Options Performance

Dielectric (single and double jacket) armored, interlock armor 2 to 288 fibers in color-coded buffer tubes Preconnectorized and specialty designs (MSHA mining) TIA/EIA-568B, ANSI/ICEA S-87-640, Telcordia GR-20, Telcordia GR-409, ANSI/ICEA S-104-696-2003 600 lbf (2,700N) 200 lbf (890N) -40°F to 176°F (-40°C to 80°C) 14°F to 176°F (-10°C to 80°C) -40°F to 176°F (-40°C to 80°C)

Flexible Buffter Tubes Water Blocking Binders Ripcord Optical Fibers

Dielectric Single Jacket

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Features and Benefits

Easy Cable Installation and Termination · Easy installation without the need for a transition point

Flame-Rated Inner Jacket Armor (corrugated steel) Flame-Rated Jacket

· Ripcord speeds cable entry and outer jacket removal · Strength yarns bend in any direction without memory

Multi-purpose Installation and Use · Optional corrugated steel tape armor provides mechanical protection and rodent resistance

Armored Double Jacket

34

www.ptsupply.com [email protected]

800-238-7514

Indoor/Outdoor Fiber

Loose Tube Riser Dielectric Single Jacket (OFNR)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216 218 to 264 266 to 288

6 6 7 8 9 10 11 12/6 14/8 15/9

6 12 12 12 12 12 12 12 12 12

.37 .44 .47 .51 .54 .58 .62 .69 .76 .80

9.4 11.2 11.9 13.0 13.7 14.7 15.7 17.5 19.3 20.3

61 79 90 102 116 132 153 196 244 269

91 119 135 153 174 198 229 294 366 404

7 9 9 10 11 11 12 14 15 16

19 22 24 26 27 29 31 35 39 41

4 4 5 5 6 6 6 7 7 8

9 11 12 13 14 15 16 18 19 20

Information based on Draka specs.

Loose Tube Riser Dielectric Double Jacket (OFNR)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216 218 to 264 266 to 288

6 6 7 8 9 10 11 12/6 14/8 15/9

6 12 12 12 12 12 12 12 12 12

.49 .56 .59 .62 .66 .70 .77 .86 .93 .96

12.4 14.2 14.9 15.7 16.6 17.7 19.4 21.6 23.4 24.3

112 137 157 172 190 223 250 302 337 353

167 204 234 257 283 333 373 450 502 526

10 11 12 12 13 14 15 17 18 19

24.8 28.4 29.8 31.4 33.2 35.4 38.8 43.2 46.8 48.6

5 6 6 6 7 7 8 9 9 10

13 15 15 16 17 18 20 22 24 25

Information based on Draka specs.

Loose Tube Riser Armored Double Jacket (OCNR)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216 218 to 264 266 to 288

6 6 7 8 9 10 11 12/6 14/8 15/9

6 12 12 12 12 12 12 12 12 12

.56 .63 .66 .70 .73 .77 .81 .93 1.00 1.04

14.2 16.0 16.8 17.8 18.5 19.6 20.6 23.5 25.3 26.3

173 201 218 238 258 286 307 346 391 417

260 301 327 357 387 429 460 519 586 625

11 13 13 14 15 15 16 19 20 21

28 32 34 36 37 39 41 47 51 53

9 9 10 11 11 12 12 14 15 16

22 24 26 27 28 30 31 36 38 40

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

35

Indoor/Outdoor Fiber

Loose Tube LSZH

Single, Double Jacket Dielectric Double Jacket Armored

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Optical Fibers

Flexible Buffter Tubes Water Blocking Binders Ripcord Strength Yarns Flame-Rated Jacket

Applications

Suitable for a combination of indoor flame-rated spaces and outdoor aerial lashed, duct and direct buried environments. By enabling placement virtually anywhere in a network, installers can bypass traditional transition points required in many installations and go directly from outside plant to riser shaft.

Specifications

Constructions Fiber Count Options Performance

Dielectric (single and double jacket) armored, interlock armor 2 to 288 fibers in color-coded buffer tubes Preconnectorized and specialty designs (MSHA mining) TIA/EIA-568B, ANSI/ICEA S-87-640, Telcordia GR-20, Telcordia GR-409, ANSI/ICEA S-104-696-2003 600 lbf (2,700N) 200 lbf (890N) -40°F to 176°F (-40°C to 80°C) 14°F to 176°F (-10°C to 80°C) -40°F to 176°F (-40°C to 80°C)

Dielectric (Single Jacket) Indoor/Outdoor

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Optical Fibers

Flexible Buffter Tubes Water Blocking Binders Ripcord

Features and Benefits

Easy Cable Installation and Termination · Easy installation without the need for a transition point

Flame-Rated Inner Jacket Armor (corrugated steel) Flame-Rated Jacket

· Ripcord speeds cable entry and outer jacket removal · Strength yarns bend in any direction without memory

Multi-purpose Installation and Use · Optional corrugated steel tape armor provides mechanical protection and rodent resistance

Armored (Double Jacket) Indoor/Outdoor Riser

36

www.ptsupply.com [email protected]

800-238-7514

Indoor/Outdoor Fiber

LSZH Dielectric Single Jacket (OFNR, Low-Smoke)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 144

6 6 7 8 9 10 11 12/6

6 12 12 12 12 12 12 12

.37 .44 .47 .51 .54 .58 .62 .69

9.4 11.2 11.9 13.0 13.7 14.7 15.7 17.5

61 79 90 102 116 132 153 196

91 119 135 153 174 198 229 294

7 9 9 10 11 11 12 14

19 22 24 26 27 29 31 35

4 4 5 5 6 6 6 7

9 11 12 13 14 15 16 18

Information based on Draka specs.

LSZH Dielectric Double Jacket (OFNR, Low-Smoke)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 144

6 6 7 8 9 10 11 12/6

6 12 12 12 12 12 12 12

.49 .56 .59 .62 .66 .70 .77 .86

12.4 14.2 14.9 15.7 16.6 17.7 19.4 21.6

112 137 157 172 190 223 250 302

167 204 234 257 283 333 373 450

10 11 12 12 13 14 15 17

24.8 28.4 29.8 31.4 33.2 35.4 38.8 43.2

5 6 6 6 7 7 8 9

13 15 15 16 17 18 20 22

Information based on Draka specs.

LSZH Armored Double Jacket (OFCR, Low-Smoke)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 36 38 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 144

6 6 7 8 9 10 11 12/6

6 12 12 12 12 12 12 12

.56 .63 .66 .70 .73 .77 .81 .93

14.2 16.0 16.8 17.8 18.5 19.6 20.6 23.5

173 201 218 238 258 286 307 346

260 301 327 357 387 429 460 519

11 13 13 14 15 15 16 19

28 32 34 36 37 39 41 47

9 9 10 11 11 12 12 14

22 24 26 37 28 30 31 36

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

37

Indoor/Outdoor Fiber

Single Jacket, Gel-Free* Riser and Plenum

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Loose Tube

Optical Fibers

Gel-Free Flexible Buffter Tubes Water Blocking Binders Ripcord Strength Yarns Flame-Rated Jacket

Applications

Suitable for a combination of indoor spaces and outdoor aerial lashed, duct and direct buried environments. By enabling placement virtually anywhere in a network, installers can bypass traditional transition points required in many installations and go directly from outside plant to riser shaft.

Specifications

Constructions Fiber Count Options Performance

Dielectric (single and double jacket), armored, interlock armor 6 to 288 fibers (depending on cable type Preconnectorized, interlock armor and specialty designs TIA/EIA-568B, ICEA 83-596, Telcordia GR-20, Telcordia GR-409, ANSI/ICEA S-104-696-2003 300 lbf ( (1,335N) ­ one buffer tube 600 lbf (2,700N) ­ more than one buffer tube 90 lbf (400N) ­ one buffer tube 200 lbf (890N) ­ more than one buffer tube -40°F to 158°F (-40°C to 70°C) 14°F to 140°F (-10°C to 60°C) -40°F to 158°F (-40°C to 70°C)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Features and Benefits

Easy Cable Installation and Termination · Gel-free design simplifies access and reduces prep time

· Ripcord speeds cable entry and outer jacket removal · Strength yarns bend in any direction without memory

Multi-purpose Installation and Use · Available with standard, 1G and 10G Ethernet multimode fibers

· Interlock armor available

*Power & Tel defines "gel free" fiber optic cables as cables with no water blocking gel between or in the buffer tubes. Cables with no water blocking gel between the buffer tubes only are described as dry.

38

www.ptsupply.com [email protected]

800-238-7514

Indoor/Outdoor Fiber

Loose Tube Riser Gel-Free Single Jacket (OFNR)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

6 to 60 72 84 96 108 120 132 144 156 to 216 218 to 288

5 6 7 8 9 10 11 12 12/6 15/9

6/12 12 12 12 12 12 12 12 12 12

.42 .45 .49 .53 .56 .60 .63 .66 .71 .82

10.6 11.4 12.3 13.4 14.2 15.1 16.0 16.9 18.0 20.8

68 80 94 111 124 141 165 183 190 254

101 120 140 165 185 211 246 273 238 378

8 9 10 11 11 12 13 13 15 16

21 23 25 27 28 30 32 34 37 42

4 5 5 5 6 6 6 7 7 8

11 11 12 13 14 15 16 17 19 20

Information based on Draka specs.

Loose Tube Plenum Gel-Free Single Jacket (OFNP)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

6 to 60 72 84 96 98 to 144

5 6 7 8 12

6/12 12 12 12 12

.37 .40 .44 .48 .61

9.3 10.2 11.1 12.2 15.6

55 66 76 98 138

82 99 119 145 206

7 8 9 10 12

19 20 22 24 30

4 4 4 5 6

9 10 11 12 14

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

39

Indoor/Outdoor Fiber

Harsh Environment, Chemical Resistant, Single/Double and Armored Double Jackets

Multimode (50µm, 62.5µm), Single Mode, Hybrid

Loose Tube

Optical Fibers

Flexible Buffter Tubes Water Blocking Binders Ripcord Strength Yarns ChemicalResistant Jacket

Applications

Heavy duty protection from harsh chemicals and solvents. Inter and intrabuilding process control, SCADA, chemical plants and airports.

Specifications

Constructions Fiber Count Options Performance

Dielectric (single and double jacket), armored (double jacket) 2 to 216 fibers Preconnectorized, interlock armor and specialty designs Telcordia GR-20, Telcordia GR-409, ANSI/ICEA S-104-696-2003 600 lbf ( (2,700N) 1,000 lbf (4,545N) ­ DXPCC only 200 lbf (890N) -40°F to 176°F (-40°C to 80°C) 14°F to 122°F (-10°C to 50°C) -40°F to 176°F (-40°C to 80°C)

Dielectric Single Jacket

Optical Fibers

Flexible Buffter Tubes Water Blocking Binders

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Inner Jacket Ripcord Strength Yarns Chemical-Resistant Outer Jacket

Features and Benefits

Dielectric Double Jacket

Optical Fibers

Robust Chemical Resistance and Protection · Chemical- and petroleum-resistant outer jacket

· Versatile loose tube design and armored option · Optional 1,000 lb. (4,444N) tensile strength for dielectric/double

jacket (DXPCC) Harsh Environment/Flame Retardant Performance · Meets OFN, OFC (tray) ­ UL 1581 and IEEE383

Flexible Buffter Tubes Water Blocking Binders Ripcord

· A single cable design can support all harsh environment

structured cabling applications

Inner Jacket Armor (corrugated steel) Chemical-Resistant Outer Jacket

· Chemical-resistant jacket

Armored Double Jacket

40

www.ptsupply.com [email protected]

800-238-7514

Indoor/Outdoor Fiber

Loose Tube Harsh Environment Dielectric Single Jacket (OFN-tray)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 26

5 6 7 8 9 10 11 12/6

12 12 12 12 12 12 12 12

.41 .44 .47 .51 .55 .58 .62 .65

10.4 11.2 11.9 13.0 14.0 14.7 15.7 16.5

62 73 82 95 110 124 139 153

93 109 123 142 165 186 209 229

8 9 9 10 11 11 12 13

21 22 24 26 28 29 31 33

4 4 5 5 6 6 6 6

10 11 12 13 14 15 16 17

Information based on Draka specs.

Loose Tube Harsh Environment Dielectric Double Jacket (OFN-tray)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216

5 6 7 8 9 10 11 12/6

12 12 12 12 12 12 12 12

.53 .56 .59 .62 .66 .70 .73 .76

13.5 14.2 15.0 15.7 16.8 17.8 18.5 19.3

108 125 139 156 179 199 221 240

162 188 209 234 269 299 331 360

11 11 12 12 13 14 15 15

27 28 30 31 34 36 37 39

6 6 6 6 7 7 7 7

14 14 15 16 17 18 19 19

Information based on Draka specs.

Loose Tube Harsh Environment Armored Double Jacket (OFC-tray)

Bend Radius No. of Buffer Tubes (outer/inner) Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 to 60 62 to 72 74 to 84 86 to 96 98 to 108 110 to 120 122 to 132 134 to 216

5 6 7 8 9 10 11 12/6

12 12 12 12 12 12 12 12

.60 .64 .66 .70 .74 .78 .81 .84

15.2 16.3 16.8 17.8 18.8 19.8 20.6 21.3

167 183 191 209 228 249 266 284

251 274 286 313 342 373 399 426

12 13 13 14 15 16 16 17

30 33 34 36 38 40 41 43

9 9 10 11 11 12 12 13

23 24 25 27 28 30 31 32

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

41

Indoor Fiber

Tight Buffer

Optical Fibers

Distribution Riser and Plenum

Color-Coded Tight Buffer Coating (900µm)

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Applications

Versatile indoor tight buffered cable.

Aramid Strength Yarns

Specifications

Constructions Fiber Count Options Performance

900µm tight buffered color-coded fiber - dielectric and interlock armor 2 to 144 Fiber (6- and 12-fiber sub units) Indoor/outdoor and specialty versions (interlock armor, tactical deployment and preconnectorized) TIA/EIA-568B, ANSI, ICEA 83-596, Telcordia GR-409, RoHS 2-12 Fiber: 150 lbs (660N) 18-144 Fiber: 300 lbs (1,320N) 2-12 Fiber: 45 lbs (220N) 18-144 Fiber: 100 lbs (444N) 2-12 Fiber: 100 lbs (444N) 18-144 Fiber: 150 lbs (660N) 2-12 Fiber: 33 lbs (133N) 18-144 Fiber: 45 lbs (200N) Riser: 500' (112m) Plenum: 500' (152m) -40°F to 176°F (-40°C to 80°C) 14°F to 176°F (-10°C to 80°C) -40°F to 176°F (-40°C to 80°C)

Flame-Rated Jacket

*Max. Installation Load (Riser) Max. Operation Load (Riser) *Max. Installation Load (Plenum) Max. Operation Load (Plenum) Vertical Rise Shipping and Storage Installation Operation

*Pull Strength

Features and Benefits

Easy Cable Installation and Termination · 900µm tight buffered fibers can be directly terminated

· Flexible small diameter cables simplify pulling and placement · Color-coded fibers and numbered sub-units simplify identification · Optional interlock armor provides robust protection and one-step installation

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), plenum (OFNP/FT-6) and LSZH

· Optional indoor/outdoor and specialty versions for applications beyond the office · UL 1666/CSA FT-4 riser · NFPA-262/UL910/CSA FT-6 plenum

42

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Tight Buffer Distribution Riser (OFNR, FT-4)

Bend Radius Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 4 6 8 12 18 24 36 48 60 72 96 144

6 6 6 12 12 12 12 12 12

.19 .22 .24 .25 .28 .52 .52 .63 .63 .70 .77 1.02 1.02

4.8 5.6 6.0 6.2 7.0 13.3 13.3 15.9 15.9 17.8 19.5 26.0 26.0

15 19 21 23 30 90 90 143 125 154 189 274 323

22 28 31 34 45 134 134 213 187 230 282 408 481

4 4 5 5 6 11 11 12 13 14 15 21 21

10 11 12 12 14 27 27 32 32 36 39 52 52

3 3 4 4 4 8 8 9 9 11 12 15 15

7 8 9 9 11 20 20 24 24 28 29 39 39

Information based on Draka specs.

Tight Buffer Distribution Plenum (OFNP, FT-6)

Bend Radius Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

Fibers per Unit

2 4 6 8 12 18 24 36 48 60 72 96 144

6 6 6 12 12 12 12 12

.17 .17 .19 .20 .28 .41 .41 .51 .53 .59 .65 .80 .90

4.2 4.3 4.7 5.0 7.0 10.3 10.3 12.9 13.3 15.0 16.6 20.4 23.0

9 14 15 18 30 72 72 115 123 153 188 316 402

13 21 22 27 45 108 108 171 183 228 280 471 599

3 3 4 4 5 8 8 10 11 12 13 16 18

8.4 8.6 9.4 9.9 11.7 21 21 26 27 30 33 41 46

3 3 3 3 4 6 6 8 8 9 10 12 13

6 7 7 7 9 16 16 19 20 23 25 31 35

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

43

Indoor Fiber

Tight Buffer

Optical Fibers

LSZH Distribution

Color-Coded Tight Buffer Coating (900µm)

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Applications

Versatile indoor tight buffered cable.

Aramid Strength Yarns

Specifications

Constructions Fiber Count Options Performance

900µm tight buffered color-coded fiber - dielectric and interlock armor 2 to 144 Fiber (6- and 12-fiber sub units) Indoor/outdoor and specialty versions (interlock armor, tactical deployment and preconnectorized) TIA/EIA-568B, ANSI/ICEA 83-596, Telcordia GR-409, RoHS 2-12 Fiber: 150 lbs (660N) 18-144 Fiber: 300 lbs (1,320N) 2-12 Fiber: 45 lbs (198N) 18-144 Fiber: 90 lbs (401N) 500' (152m) -40°F to 176°F (-40°C to 80°C) 14°F to 122°F (-10°C to 50°C) -4°F to 176°F (-20°C to 80°C)

Flame-Rated Jacket

*Max. Installation Load Max. Operation Load Vertical Rise Shipping and Storage Installation Operation

*Pull Strength

Features and Benefits

Easy Cable Installation and Termination · 900µm tight buffered fibers can be directly terminated

· Flexible small diameter cables simplify pulling and placement · Color-coded fibers and numbered sub-units simplify identification · Optional interlock armor provides robust protection and one-step installation

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), plenum (OFNP/FT-6) and LSZH

· Optional indoor/outdoor and specialty versions for applications beyond the office · UL 1666/CSA FT-4 riser · NFPA-262/UL910/CSA FT-6 plenum

44

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Tight Buffer LSZH Distribution (OFNR, FT-4)

Bend Radius Fibers per Unit or No. of Units Diameter inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

Fiber Count

2 4 6 8 12 18 24 36 48 60 72 96 144

6 6 6 12 12 12 12 12

.22 .22 .24 .25 .28 .52 .52 .63 .63 .70 .77 1.02 1.02

5.6 5.7 6.1 6.3 7.1 13.3 13.3 15.9 15.9 17.8 19.5 25.8 25.8

15 21 22 24 31 97 97 148 130 161 198 304 304

22 31 32 36 46 145 145 220 194 240 295 453 453

4 5 5 5 6 11 11 13 13 14 15 20 20

11 11 12 13 14 27 27 32 32 36 39 52 52

3 3 4 4 4 8 8 9 9 11 12 15 15

8 9 9 10 11 20 20 24 24 27 29 39 39

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

45

Indoor Fiber

Tight Buffer

Optical Fibers Tight Buffered Fiber (900µm) Central Strength Member Aramid Strength Yarns Ripcord

Breakout Riser and Plenum

Multimode (50µm, 62.5µm), Enhanced Single Mode (ESMF), Hybrid

Applications

Robust multi-fiber indoor breakout, routing and connectorization.

Specifications

Constructions Fiber Count Options Performance

Jacketed cordage (2.5mm units) with 900µm tight buffered fiber; dielectric and interlock armor 2 to 24 fiber Preconnectorized; 2.5mm units TIA/EIA-568B, ANSI/ICEA S-83-596, Telcordia GR-409, RoHS 2-12 Fiber: 150 lbf (660N) 14-24 Fiber: 300 lbf (1,335N) 2-12 Fiber: 45 lbf (200N) 14-24 Fiber: 80 lbf (400N) 2-12 Fiber: 100 lbf (440N) 14-24 Fiber: 150 lbf (660N) 2 Fiber: 113 lbf (500N) 4-8 Fiber: 250 lbf (110N) 10-12 Fiber: 270 lbf (1,200N) 14-24 Fiber: 45 lbf (200N) -40°F to 176°F (-40°C to 80°C) 14°F to 122°F (-10°C to 50°C) -4°F to 176°F (-20°C to 80°C)

Flame-Rated Jacket (outer)

*Max. Installation Load (Riser) Max. Operation Load (Riser) *Max. Installation Load (Plenum) Max. Operation Load (Plenum)

Shipping and Storage Installation Operation

*Pull Strength

Features and Benefits

Easy Cable Entry and Termination · 2.5mm units with 900µm tight buffered fibers provide simple direct field termination

· Flexible robust cables simplify pulling and placement · Numbered sub-units simplify identification and routing · Optional interlock armor provides robust protection and one-step installation

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), plenum (OFNP/FT-6) and LSZH

· A single cable design can support all structured cabling applications

46

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Tight Buffer Breakout Riser (OFNR, FT-4)

Bend Radius Diameter inch mm .29 .33 .38 .44 .53 .53 .53 .58 .58 .68 7.3 8.3 9.6 11.3 13.4 13.4 13.4 14.7 14.7 17.3 Approximate Cable Weight lb/K-ft kg/km 33 41 57 78 108 108 108 125 125 166 49 60 85 116 161 161 161 186 186 247 Load inch 6 7 8 9 11 11 11 12 12 14 cm 15 17 20 23 27 27 27 30 30 35 No Load inch cm 4 5 6 7 8 8 8 9 9 10 11 13 15 17 21 21 21 23 23 26

Fiber Count 2 4 6 8 10 12 14 16 18 24

Information based on Draka specs.

Tight Buffer Breakout Plenum (OFNP, FT-6)

Bend Radius Diameter inch mm .23 .28 .33 .39 .46 .52 .50 .56 .56 .65 5.8 7.0 8.5 10.0 11.6 13.3 12.8 14.1 14.1 16.5 Approximate Cable Weight lb/K-ft kg/km 25 31 44 66 93 125 96 114 112 158 36 45 65 97 138 186 143 169 166 235 Load inch 5 6 7 8 9 11 10 11 11 13 cm 12 14 17 20 24 27 26 29 29 33 No Load inch cm 4 4 5 6 7 8 8 9 9 10 9 11 13 15 18 20 20 22 22 25

Fiber Count 2 4 6 8 10 12 14 16 18 24

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

47

Indoor Fiber

Tight Buffer

Optical Fibers

LSZH Breakout

Color-Coded Tight Buffer Coating (900µm)

Multimode (50µm, 62.5µm), Single Mode (ESMF), Hybrid

Applications

Versatile indoor tight buffered cable

Aramid Strength Yarns

Specifications

Constructions Fiber Count Options Performance

900µm tight buffered color-coded fibers - dielectric and interlock armor 2 to 144 fibers (6 and 12 fiber sub units) Indoor/outdoor and specialty versions (interlock armor, tactical deployment and preconnectorized) TIA/EIA-568B, ANSI/ICEA S-83-596, Telcordia GR-409, RoHS 2-14 Fiber: 150 lbs (660N) 16-24 Fiber: 300 lbs (1,320N) 2-12 Fiber: 45 lbs (220N) 14-24 Fiber: 90 lbs (400N) -40°F to 176°F (-40°C to 80°C) 14°F to 122°F (-10°C to 50°C) -4°F to 176°F (-20°C to 80°C)

Flame-Rated Jacket

*Max. Installation Load Max. Operation Load Shipping and Storage Installation Operation

*Pull Strength

6-Fiber Cable

Features and Benefits

Easy Cable Installation and Termination · 900µm tight buffered fibers can be directly terminated

· Flexible small diameter cables simplify pulling and placement · Color-coded fibers and numbered sub-units simplify identification · Optional interlock armor provides robust protection and one-step installation

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), plenum (OFNP/FT-6) and LSZH

· Optional indoor/outdoor and specialty versions for applications beyond the office · UL 1666/CSA FT-4 riser · NFPA-262/UL910/CSA FT-6 plenum

48

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Tight Buffer LSZH Breakout (OFN, FT-4)

Bend Radius Diameter inch mm .29 .33 .38 .45 .50 .57 .58 .58 .58 .68 7.4 8.4 9.7 11.4 12.8 14.5 14.7 14.7 14.7 17.2 Cable Weight lb/K-ft kg/km 33 39 56 82 107 138 133 133 133 180 48 57 83 122 159 205 198 198 198 268 Load inch 6 7 8 9 10 11 12 12 12 14 cm 15 17 20 23 26 29 30 30 30 35 No Load inch cm 2 3 3 4 4 4 5 5 5 5 6 7 8 9 10 11 12 12 12 13

Fiber Count 2 4 6 8 10 12 14 16 18 24

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

49

Indoor Fiber

Tight Buffer

Simplex and Duplex Riser, Plenum and LSZH

Optical Fiber

Tight Buffered Fiber (900µm)

Multimode (50µm, 62.5µm), Enhanced Single Mode (ESMF)

Applications

Simple fiber patching, routing and connectorization, Simplex and Duplex interconnect.

Aramid Strength Yarns

Specifications

Constructions Fiber Count Options

1 fiber Simplex, 2 fiber zipcord, 1 fiber round, 900µm tight buffered fiber 1 or 2 fiber Cordage diameter (1.6mm, 2mm and 2.9mm), preconnectorized assemblies (SC, LC, FC and others), fiber type TIA/EIA-568B, ANSI/ICEA S-83-596, Telcordia GR-409, RoHS 1 Fiber, Type 516: 33 lbs (150N) 1 Fiber, Types 520 and 529: 50 lbs (220N) 2 Fiber, Type 516Z: 33 lbs (150N) 2 Fiber, Types 520Z, 529Z and 529R: 50 lbs (220N) 1 Fiber, Type 516: 10 lbs (45N) 1 Fiber, Types 520 and 529: 15 lbs (66N) 2 Fiber, Type 516Z: 10 lbs (45N) 2 Fiber, Types 520Z, 529Z and 529R: 15 lbs (66N) 1 Fiber, Type 816: 33 lbs (150N) 1 Fiber, Types 820 and 829: 50 lbs (220N) 2 Fiber, Type 816Z: 33 lbs (150N) 2 Fiber, Types 820Z and 829Z: 50 lbs (220N) 1 Fiber, Type 816: 10 lbs (45N) 1 Fiber, Types 820 and 829: 15 lbs (66N) 2 Fiber, Type 816Z: 10 lbs (45N) 2 Fiber, Types 820Z and 829Z: 15 lbs (66N) 1 Fiber, Type LSZH16: 33 lbs (150N) 1 Fiber, Type LSZH20 and LSZH29: 50 lbs (220N) 2 Fiber, Type LSZH16Z: 33 lbs (150N) 2 Fiber, Type LSZH20Z, LSZH29Z and LSZH29V: 50 lbs (200N) -40°F to 176°F (-40°C to 80°C) 32°F to 122°F (0°C to 50°C) -4°F to 122°F (-20°C to 80°C)

Flame-Rated Jacket

1-Fiber Simplex

Performance *Max. Installation Load (Riser)

Max. Operation Load (Riser)

Optical Fiber

*Max. Installation Load (Plenum)

Tight Buffered Fiber (900µm)

Max. Operation Load (Plenum)

Aramid Strength Yarns

*Max. Installation Load (LSZH)

Flame-Rated Jacket

Shipping and Storage Installation Operation

*Pull Strength

2-Fiber Zipcord

50

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Tight Buffer Riser (OFNR, FT-4)

Bend Radius Diameter Fiber Count inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

1 1 1 2 (Zipcord) 2 (Zipcord) 2 (Zipcord) 2 (Duplex, round)

.063 .079 .114 .063 x .143 .079 x .173 .114 x .237 .113

1.6 2.0 2.9 1.6 x 3.6 2.0 x 4.4 2.9 x 6.0 2.9

2 2 5 4 5 9 5

3 4 7 6 8 14 6.4

1 4 2 1 2 2 2

3 2 6 3 4 6 6

1 1 2 1 1 2 2

2 3 4 2 3 4 4

Information based on Draka specs.

Tight Buffer Plenum (OFNP, FT-6)

Bend Radius Diameter Fiber Count inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

1 1 1 2 (Zipcord) 2 (Zipcord) 2 (Zipcord)

.063 .079 .114 .063 x .143 .079 x .173 .114 x .237

1.6 2.0 2.9 1.6 x 3.6 2.0 x 4.4 2.9 x 6.0

2 3 4 4 6 11

3 4 6 6 8 16

1 2 2 1 2 2

3 4 6 3 4 6

1 1 2 1 1 2

2 3 6 2 3 4

Information based on Draka specs.

Tight Buffer LSZH (OFNR, FT-6)

Bend Radius Diameter Fiber Count inch mm Cable Weight lb/K-ft kg/km Load inch cm No Load inch cm

1 1 1 2 (Zipcord) 2 (Zipcord) 2 (Zipcord) 2 (Duplex, oval)

.063 .079 .114 .063 x .143 .079 x .173 .114 x .237 .203 x .316

1.6 2.0 2.9 1.6 x 3.6 2 x 4.4 2.9 x 6 5.2 x 8

3 4 8 4 5 10 32

3 4 8 5 8 15 47

1 2 2 1 2 2 4

3 4 6 3 4 6 10

1 1 2 1 1 2 3

2 3 4 2 3 4 8

Information based on Draka specs.

Features and Benefits

Easy Cable Installation and Termination · 900µm tight buffered fibers can be directly terminated with strain relief

Flame-Retardant Safety · UL 1666/CSA FT-4 OFNR riser option

· Flexible design · Easily strippable fiber coatings · Zipcord cable can be easily separated into two Simplex

units

· NFPA-262/UL910/CSA FT-6 OFNR

plenum option

www.ptsupply.com [email protected]

800-238-7514

51

Indoor Fiber

Loose Tube

Interlock Armor, Riser and Plenum

Single mode, Multimode, Hybrid

Central Strength Member Optical Fibers Color-Coded Tight Buffer Coating (900µm) Aramid Strength Yarns 6 Fiber Sub-Unit (18-36 fibers) 12 Fiber Sub-Unit (36-144 fibers) Ripcord

Applications

Indoor protective crush resistance and fire safety. Interlocked armor eliminates the need for ductwork or conduit. Cables utilizing this armor option are ideally suited for routing inside plenum areas or in riser shafts.

Specifications

Constructions Fiber Count Options Performance

Interlock armor 2 to 144 fibers Flame-retardant ratings/Bare, stripe or jacket/ Aluminum or steel armor TIA/EIA-568B, ANSI/ICEA S-83-596, Telcordia GR-409, RoHS 300 lbf (1,335N) 12f: 150 lbf (660N) 100 lbf (444N) 12f: 45 lbf (198N) -40°F to 176°F (-40°C to 80°C) 14°F to 122°F (-10°C to 50°C) -4°F to 176°F (-20°C to 80°C)

Flame-Rated Jacket (unit) Interlock Armor

Outer Jacket (optional)

Maximum Installation Load Maximum Operation Load Shipping and Storage Installation Operation

Interlock Armor

Central Strength Member Optical Fibers

Features and Benefits

Easy Cable Entry and Preparation · Easy cable installation

· Designed for loose tube or tight buffered designs for optimal fiber

performance

Color-Coded Tight Buffer Coating (900µm)

· Color-coded for easy identification

Flame-Retardant Safety · Versions for riser (OFNR/FT-4), Plenum (OFNP/FT-6) and LSZH

Ripcord Flame-Rated Jacket (unit) Interlock Armor Ripcord Outer Jacket (optional)

Interlock Armor Loose Tube

52

www.ptsupply.com [email protected]

800-238-7514

Indoor Fiber

Loose Tube Interlock Armor Riser (OFCR FT-4)

Fiber Count 2 4 6 8 10 12 18 24 30 36 36 48 60 72 96 144 Fibers per Unit 6 6 6 6 12 12 12 12 12 12 in .52 .55 .57 .57 .59 .61 .85 .85 .90 .95 .96 .96 1.03 1.10 1.35 1.35 Diameter mm 13.2 14.0 14.5 14.5 15.0 15.5 21.6 21.6 22.9 24.1 24.4 24.4 26.2 27.9 34.3 34.3 Cable Weight lb/K-ft kg/km 119 127 131 134 137 145 279 270 307 374 374 365 411 469 671 671 179 190 196 201 205 217 419 405 460 560 560 547 616 703 1,006 1,006 Load inch 10 11 11 11 12 12 17 17 18 19 19 19 20 22 27 27 cm 26 28 29 29 30 31 43 43 46 48 49 49 52 56 69 69 Bend Radius No Load inch cm 8 8 9 9 9 9 13 13 13 14 15 15 15 17 20 20 20 21 22 22 23 23 32 32 34 36 37 37 39 42 51 51

Information based on Draka specs.

Loose Tube Interlock Armor Plenum (OFCP FT-6)

Fiber Count 2 4 6 8 10 12 18 24 30 36 36 48 60 72 96 144 Fibers per Unit 6 6 6 6 12 12 12 12 12 12 in .43 .44 .46 .46 .48 .50 .67 .67 .75 .81 .83 .83 .89 .95 1.10 1.20 Diameter mm 11.0 11.2 11.6 11.8 12.3 12.7 16.9 16.9 19.1 20.6 21.0 21.0 22.7 24.2 28.0 30.6 Cable Weight lb/K-ft kg/km 120 127 130 135 137 142 248 248 312 349 349 362 420 537 760 895 179 190 196 201 205 217 419 405 460 560 560 547 616 703 1,006 1,006 Load inch 9 9 9 9 10 10 13 13 15 16 17 17 18 19 22 24

Bend Radius No Load inch cm 7 7 7 7 7 7 10 10 11 12 13 13 13 14 17 18 17 17 17 18 18 19 25 25 29 31 32 32 34 36 42 46

cm 22 22 23 24 25 25 34 34 38 41 42 42 45 48 56 61

Information based on Draka specs.

www.ptsupply.com [email protected]

800-238-7514

53

Fiber Optic Cable

Notes

54

www.ptsupply.com [email protected]

800-238-7514

Information

54 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

830488


You might also be interested in

BETA
Microsoft Word - AMP_NETCONNECT_Fiber_Optic_IO_Cables_Rev_G.doc
8Cable Assemblies.cdr
Anixter Wire & Cable Technical Information Handbook