Read vco1324.pdf text version

M3500-1324

(1350-2400 MHZ)

1K. M3500-1324 VCO TECHNICAL SPECIFICATIONS TYPICAL PERFORMANCE (0-70° C)

PARAMETER

Nominal Supply Voltage Power Output (50) Typical Current Tuning Voltage FM(Phase)Noise:

ABSOLUTE MAXIMUM / MINIMUM RATINGS

PARAMETER

Maximum Supply Voltage Tuning Voltage Min/Max

RATING

+15.0V 0/20V

DATA

+12V +7 dBm 20mA 1.0-12.0 V <- 85 dBc/Hz <-106 dBc/Hz <-124 dBc/Hz 4.0 MHz/V for 12 ± 1V 34 MHz peak-peak -12 dBc 9.6 MHz 34.7 MHz 36.0 MHz

10 kHz Offset 100 kHz Offset 1 MHz Offset

GUARANTEED PERFORMANCE (0-70° C)

PARAMETER

Power Dissipation Frequency Tuning Range Power Output (50)

DATA

300 mW max (25 mA @ +12V) 1350 to 2400 MHz min 5 dBm min

Frequency Pushing Frequency Pulling (12dB Return Loss) Harmonic Spurious (Average) Tuning Port Bandwidth: @ Tuning Voltage = 2.0V @ Tuning Voltage = 8.0V @ Tuning Voltage = 12.0V

2K. PERFORMANCE CURVES FOR M3500-1324 1350-2400 MHZ TYPICAL OUTPUT FREQUENCY / MODULATION SENSITIVITY VERSUS TUNING VOLTAGE

FREQUENCY

KV

1350-2400 MHZ VCO TYPICAL OUTPUT POWER VERSUS TUNING VOLTAGE

MICRONETICS / 26 HAMPSHIRE DRIVE / HUDSON, NH 03051 / TEL: 603-883-2900 / FAX: 603-882-8987 / CUSTOMER HOTLINE: 1-800-963-3382 / WEB: WWW.MWIRELESS.COM