Read QTS EcoCladDrawings create text version

QT EcoClad

QT Systems

PO Box 6249 Acacia Ridge DC Q 4110 Australia Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Standard QT® EcoClad Panel Fixing - Type 1 (A)

200

112

225 600 maximum stud centres 225mm Maximum edge fixing distance for unsupported wall cantilevers 112 225 225

112 Maximum fixing centres 900

50

Alternative fixing centres

50

200

Fixing centres 200 200

900

Bond horizontal and vertical joints with polyurethane foam adhesive

Wall Panel Fixing Details

Wall Panel Cavity

50mm Minimum end fixing distance

Wall Panel Edge Fixing Details

Panel Fixing Fix the 50mm QT®EcoClad Wall Panels onto battens with galvanised 10g x 75mm class 3 (AS3566) screws with the addition of QT®Button in all cases. General Notes 1. Panels must span and be fixed across a minimum of two metal battens. 2. Panels shall be installed horizontally in a stretcher bond pattern. 3. Panels must be installed level and plumb to achieve the best possible finish. 4. A vapour permeable sarking must be installed prior to installation of battens.

QT EcoClad

QT Systems

PO Box 6249 Acacia Ridge DC Q 4110 Australia Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Standard QT® EcoClad Panel Fixing - Type 2 (A)

Bond horizontal and vertical joints with polyurethane foam adhesive. Trimdek or Spandek profiled wall sheeting

200

112

225 225

112 112 Maximum fixing centres 900 225 225

Alternative fixing centres

50

200

Fixing centres 200 200

900

50

Panel Fixings Centres

2 Ribs maximum centres - Trimdek 4 Ribs maximum centres - Spandek

Wall Panel Fixing Details

225mm Maximum edge fixing distance for unsupported wall cantilevers

Wall Panel Cavity

50mm Minimum end fixing distance

Wall Panel Edge Fixing Details

Panel Fixing Fix the 50mm QT®EcoClad Wall Panels onto battens with galvanised 10g x 75mm c lass 3 (AS3566) screws with the addition of QT®Button in all cases. General Notes 1. Panels must span and be fixed across a minimum of two metal battens. 2. Panels shall be installed horizontally in a stretcher bond pattern. 3. Panels must be installed level and plumb to achieve the best possible finish. 4. A vapour permeable sarking must be installed prior to installation of battens.

QT EcoClad

QT Systems

PO Box 6249 Acacia Ridge DC Q 4110 Australia Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Type 1 (A) - Batten Fixings

Batten centres Refer Table

Wall girts

Fixings (refer table) 1200 (max)

Wall girts 1200 (max) Metal battens (refer table for type and fixing details) Batten Spacing at 450 ???? BHP STRAMIT 0.55 BMT ,

2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers

Fixings (refer table)

Wall girts

Concrete slab

Fixings (refer table)

Wind Classification

N2(W33N) N3(W41N) N4(W50N) N5(W60N) N2(W70N)

Batten Spacing at 600 crs BHP STRAMIT 0.55 BMT , BHP STRAMIT 0.75 BMT ,

2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers 2-off - 10-16mm Class 3, Self Drilling Hex Head Screw with Neo Washers -

General Notes

1. Metal Batten must have two fixings (as per table) in each wall girt. 2. Structural Steel Frame including wall girts must be designed by an engineer and must allow for the applied load of the 50mm Conpolcrete® (20kg/m2). 3. All screws must be a minimum class 3. 4. External wall sheeting must be fixed thought the 50mm Conpolcrete® Wall Panel and into the wall girts (extended wall sheeting screws required).

250

Metal flashing

2000

QT EcoClad

QT Systems

PO Box 6249 Acacia Ridge DC Q 4110 Australia Ph: +61 7 3272 3424 Fx: +61 7 3272 3406

Type 2 (A) - Wall Sheet Fixing

Panel Fixings Centres

2 Ribs maximum centres - Trimdek 4 Ribs maximum centres - Spandek Fixings (refer wall profile)

Wall girts 1200(max) Wall girts 1200(max) Wall girts Concrete slab Fixings (refer wall profile) Wall sheeting Trimdek or Spandek

Trimdek or Similar Profile 1. Trimdek Base Wall Sheeting - must be valley fixed beside each rib with 10-16 x 16mm class 3, self drilling, hex head screws with neo washers at each wall girt. (0.42 BMT Zincalume or Colorbond). 2. Trimdek External Wall Sheeting - must be fixed through the 50mm Conpolcrete® wall panel and into each wall girt beside each rib with 14-10 x 115mm Class 3, self drilling, hex head screws with neo washers. (0.42 BMT Zincalume or Colorbond). Spandek or Similar Profile 1. Spandek Base Wall Sheeting - must be valley fixed beside every second rib with 10-16 x 16mm class 3, self drilling, hex head screws with neo washers at each wall girt. (0.42 BMT Zincalume or Colorbond). 2. Spandek External Wall Sheeting - must be fixed through the 50mm Conpolcrete® wall panel and into each wall girt beside every second rib with 14-10 x 115mm Class 3, self drilling, hex head screws with neo washers. (0.42 BMT Zincalume or Colorbond).

250

Metal flashing

2000