ROOF & WALL CLADDING SYSTEMS SELECTOR

QUEDRON ROOFING & CLADDING PRODUCTS

The comprehensive range of cladding solutions

A range of specifically developed integrated construction solutions designed to offer specifiers the ultimate benefits in performance, sustainability, design flexibility and lifetime cost.

CLADDING SYSTEMS

QUEDRON SYSTEM BENEFITS

This portfolio has been introduced to meet the increasing pressure on all building envelopes to satisfy the demands for improved air tightness, thermal transmission, fire resistance, sound reduction and recyclability. It is here our systems excel, where the design flexibility of built up constructions, their aesthetic form and ability to be curved and adapt to many architectural structures far outweighs any benefits offered by the traditional rigid foam cored composite panel.

QUEDRON TECHNICAL SUPPORT

Offering an extremely attractive combination of high product quality at competitive rates, all Qsystem building solutions are fully backed up with in-depth technical support. This support package ranges from specialist in-house advisors to informative literature, fully tested and accredited performance data and a direct liaison service to architects, engineers and on-site contractors.

QUEDRON QUALITY ASSURANCE

Quedron's commitment to quality and service is paramount and all our products are manufactured under a Quality Management System accredited to ISO 9001:2000. Personnel have also undergone extensive training to ensure the high standards demanded of cladding envelope systems are easily and confidently achieved.

www.quedron.co.uk

2

ROOF CLADDING

ROOF CLADDING SYSTEMS

Design Benefits Thermal Sound Reduction Sound Absorption

Q SYSTEM Q SYSTEM Q SYSTEM

RG 25 RR 25 RA 25

4 5 6 7

ROOF DECKING

ROOF DECKING SYSTEMS

Design Benefits Built Up Single Ply Structural Acoustic 8

Q SYSTEM Q SYSTEM Q SYSTEM

BD 25 SD 25 AD 25

9 10 11

WALL CLADDING SYSTEMS

Design Benefits Vertical Systems Thermal Sound Reduction Sound Absorption Horizontal Systems Thermal Sound Reduction Q SYSTEM Q SYSTEM Q SYSTEM Q SYSTEM Q SYSTEM VG 35 VR 35 VA 35 HG 35 HR 35 13 14 15 16 17 12

WALL CLADDING FIRE WALL CLADDING

FIRE WALL CLADDING SYSTEMS

Introduction Vertical 4hr (Glass Fibre) Vertical 4hr (Rockwool) Horizontal 4hr (Rockwool) 18

Q SYSTEM Q SYSTEM Q SYSTEM

VGF 35 VRF 35 HRF 35

20 22 24

TECHNICAL

Profile Selector Specification Technical Services

SYSTEM

REFERENCES

26 34 38

TECHNICAL

QUEDRON ROOFING & CLADDING PRODUCTS

3

design benefits

SPECIFICATION FLEXIBILITY

Quedron profiles can be supplied in a wide range of different materials, BBA certified coatings, BS and RAL colour options, meeting the most stringent life expectancy, structural and aesthetic demands.

Roof Cladding systems

THERMAL PERFORMANCE

All Qsystems shown are Building Regulations Approved Document L2 compliant. However, bespoke systems tailored to suit individual client requirements can be easily accommodated by using deeper variants of our standard spacer system (0.20W/m2K) or our newly launched revolutionary `mast' system which gives the designer the potential to specify systems with `U' values in excess of 0.16W/m2K. All Qsystems can be specified in the knowledge that they offer thermal performance longevity for the life of the building.

ACOUSTIC PERFORMANCE

Excellent sound reduction performance; typically between 41 ­ 48dB (weighted S.R.I. Rw) - subject to system choice and product specification. Tests have shown that mineral fibre in direct contact with the outer sheet provides very effective damping performance. These acoustic benefits are significant when considering `noise pollution' created by rain drumming. Reduction and damping performance of Quedron built up constructions are typically between 10 - 20dB better than the equivalent foam cored composite panel construction. A 10dB reduction in acoustic terms will approximately halve the loudness. Further reduction by 10dB will halve the level again. Systems are also available with perforated internal linings to provide excellent levels of sound absorption and contribute to lowered reverberation time.

FIRE RESISTANCE

Products contained within Qsystems can be deemed non combustible in accordance with stringent British Standards. No reliance is made on test methods laid out by other independent or trade associated bodies to claim performance ­ commonly undertaken with foam cored composite panel.

INSTALLATION

Logistically less demanding than composite panels due to their nestable nature, Quedron products take fewer lorries to deliver, use up far less site storage space and are easier and lighter to handle with less reliance on constant cranage. A choice of lining panel gauges allows the designer the option to specify the entire roof envelope `fully lined out'. This method of installation provides a dry working area beneath quicker than any composite panel installation times, thus allowing internal trades to commence work earlier and therefore, improve the building completion period. Due to their flexibility, Qsystem sheets accept larger steelwork tolerances than rigid composite panels, thus preventing possible air permeability, support bearing and fastener stress problems.

AIR PERMEABILITY

When installed to manufacturer's recommendations all Qsystems can easily achieve and significantly improve upon the 10m3/hr/m2 @ 50 Pa maximum air leakage stipulation as laid out within Building Regulations Approved Document L2 (2006).

(Further reading: Corus Technical Paper ­ Creating an air-tight building envelope. Refer to Quedron Technical Department or download at www.quedron.co.uk).

SUSTAINABILITY

Products contained within Qsystems are recyclable with no additional greenhouse gases and do not present the potential ecological impact presented by foam cored composite panels.

(Further reading: Corus Technical Paper ­ End of life options for pre-finished steel buildings. Please consult our Technical Department or download at www.quedron.co.uk).

COST

Qsystems are economic, have good lifetime performance and do not present high disposal costs at the end of their life.

4

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Double Skin Insulated Roof System with Glass Fibre Insulation - 0.25 `U' Value

Q SYSTEM

RG 25

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

A high quality cost effective fastrack roof system offering ecological, fire resistance and design flexibility benefits over the traditional PUR foam cored composite panel.

<0.25W/m2K

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>41dB AA

(Highest)

G

External Fire Exposure Classification (BS476 Part 3) Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

G

0

(Highest)

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

G

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 180mm thick Knauf Factoryclad 40 compressed to 170mm. ( = 0.040W/mK) 170mm deep Quedron Spacer System. Brackets at 1m centres. Lining Panel - Sealed side and end laps. 0.40mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm >5 degrees - trapezoidal sections >2.5 degrees - secret fix option.

G G

Air Permeability

(Building Regulations Approved Document L2 compliant)

External Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

G

Internal Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

Class C

(1.8m centres)

Insulation

G

Design Flexibility/Bespoke systems Curved barrel vault/eaves/ridge options Ecological effect Sustainability/Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes Available Available

Notes: Up to

Spacer System Vapour Control Layer Internal Sheet

G

G

G

G

G

G

Typical Purlin Centres Minimum Design Roof Pitch

30yrs Yes Yes

Secret fix option uses 180mm deep brackets. System can be upgraded to achieve Class B Non-fragility rating using 0.70mm thick lining. Refer to page 26 for profile options and page 34 for profile specific system references and performance data.

G

5

THERMAL

Double Skin Insulated Roof System with Rockwool Insulation - 0.25 `U' Value

Q SYSTEM

RR 25

SYSTEM BENEFITS

G

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.25W/m K

2

G

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>47dB AA

(Highest)

Offering similar benefits over PUR foam cored composite panels as our RG 25 system but with greater sound reduction performance and rain drumming/noise damping characteristics, making this ideal for education and retail facilities.

G

External Fire Exposure Classification (BS476 Part 3) Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

G

0

(Highest)

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 180mm thick Rockwool Cladding Roll insulation quilt ( = 0.040W/mK) 180mm deep Quedron Spacer System. Brackets at 1m centres. Lining Panel - Sealed side and end laps 0.70mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm >5 degrees - trapezoidal sections >2.5 degrees - secret fix option.

G

External Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

G

Internal Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

Class B

(2.1m centres)

Insulation

G

Design Flexibility/Bespoke systems Curved barrel vault/eaves/ridge options Ecological effect Sustainability/Recyclability NBS Specifications Profile CAD blocks Material Warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes Available Available

Up to

G

Spacer System Vapour Control Layer Internal Sheet

G

G

G

G

G

Note: Refer to page 26 for profile options and page 34 for profile specific system references and performance data.

G

30yrs Yes Yes

Typical Purlin Centres Minimum Design Roof Pitch

G

SOUND REDUCTION

6

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Double Skin Acoustic Roof System with Perforated Lining - 0.25 `U' Value

Q SYSTEM

RA 25

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.25W/m2K

A high performance roof system combining thermal and acoustic benefits. The perforated internal lining and acoustic Rockwool mat allows excellent levels of sound absorbency to be achieved providing an ideal solution for conference areas, sports halls etc.

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>30dB 0.55

(@500Hz)

G

Calculated Absorption Coefficient External Fire Exposure Classification (BS476 Part 3) Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

G

AA

(Highest)

G

0

(Highest)

SPECIFICATION

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

External Sheet

0.70mm thick colour coated galvanised steel Quedron profiled sheet. 150mm thick Rockwool Cladding Roll insulation quilt. ( = 0.040W/mK) 150mm deep Quedron Spacer System. Brackets at 1m centres. Separate sealed membrane. 30mm thick Rockwool RW3 acoustic slab ( = 0.034W/mK) with 50mm deep top hat spacer to accept thermal spacer system. 0.70mm thick colour coated galvanised steel fully perforated Quedron lining panel. (30% open area). 1100 - 1800mm >5 degrees - trapezoidal sections >2.5 degrees - secret fix option.

Noncombustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

Insulation

G

External Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

Spacer System Vapour Control Layer Acoustic Layer

G

Internal Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

Class C

(1.8m centres)

G

Design Flexibility/Bespoke systems Curved barrel vault/eaves/ridge options Ecological effect Sustainability/Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes Available Available

Up to

G

G

G

Internal Sheet

G

G

G

Typical Purlin Centres Minimum Design Roof Pitch

30yrs

G

Yes Yes

Note: Refer to page 26 for profile options and page 34 for profile specific system references and performance data.

G

7

SOUND ABSORPTION

design benefits

SPECIFICATION FLEXIBILITY

Qdeck sections can be supplied in a wide range of different materials, coatings and colour options to meet life expectancy, structural and aesthetic demands. Qdeck sections can be used to support single ply membrane or profiled roof systems. Very low pitch applications are easily achieved.

Roof Decking systems

`Standing seam' appearance single ply membrane systems are available. Qdeck sections allow a multitude of design options such as convex, concave and even tapered curve elevations.

STRUCTURAL PERFORMANCE

Structural deck sections offer long span capability thus omitting the secondary support content. Lightweight construction and fewer supports helps reduce the load on the primary structure thus allowing lighter design and reduced costs. Qdeck sheets may be used to laterally restrain the top flange of the secondary support structure. Qdeck sections can be used within diaphragm roof design to eliminate in-plane roof bracing.

THERMAL PERFORMANCE

All Qdeck systems shown are Building Regulations Approved Document L2 compliant. Bespoke `U' values can be easily accommodated with simple modification.

ACOUSTIC PERFORMANCE

Excellent sound reduction and damping performance can be achieved with our solid Qdeck systems. Qdeck sections are available perforated offering good levels of sound absorption and reduced reverberation.

FIRE RESISTANCE

All Qdeck sections achieve a Class 1 fire rating in accordance with BS476: Part 7 and meet Class 0 requirements as laid out within current Building Regulations.

INSTALLATION

Logistically less demanding than composite deck panels due to the nestable nature of profiled single skin, Qdeck products take up far less site storage space and are easier and lighter to handle. Qdeck can be secured to provide a dry working area beneath quicker than composite deck panel installation times. This fastrack installation allows internal trades to commence work earlier and therefore can improve building completion times. Due to their flexibility, Qdeck sections accept larger steelwork tolerances than rigid composite deck panels, thus preventing possible side lap air sealing, end lap bearing and fastener stress problems.

AIR PERMEABILITY

If installed to manufacturer's recommendations all Qdeck systems can easily achieve and significantly improve upon the 10m3/hr/m2 @ 50 Pa maximum air leakage stipulation as laid out within Building Regulations Approved Document L2 (2006).

(Further reading: Corus Technical Paper ­ Creating an air-tight building envelope. Refer to Quedron Technical Department or download at www.quedron.co.uk).

SUSTAINABILITY

Qdeck sections are recyclable with no additional greenhouse gases and do not present potential ecological impact.

(Further reading: Corus Technical Paper ­ End of life options for pre-finished steel buildings. Please consult our Quedron Technical Department or download at www.quedron.co.uk).

COST

Qdeck products are economic, have good lifetime performance and do not present high disposal costs at the end of their life.

8

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Built Up Insulated Single Ply Roof Decking System - 0.25 `U' Value

Q SYSTEM

BD 25

SYSTEM BENEFITS

A single ply membrane roof system incorporating profiled decking, offering the specifier fastrack, low pitch, cost, aesthetic and longevity benefits combined with the design freedom that membranes allow.

G

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.25W/m2K

G

Estimated Average Sound Reduction

(weighted S.R.I Rw)

>35dB* AA

(Highest)

G

External Fire Exposure Classification

(BS476 Part 3)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

0

(Highest)

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

SPECIFICATION

External Membrane Insulation** Fully sealed waterproof PVC single ply membrane. 150mm thick Rockwool Hardrock Dual Density Tissue Faced insulation board. ( = 0.039W/mK)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Deck Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

G

Design Flexibility/Bespoke systems Curved barrel vault option Ecological effect Sustainability / Recyclability NBS Specifications Profile CAD blocks System warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes

Notes:

G

G

Vapour Control Layer Separate membrane or sealed side and end laps of deck section. Internal Sheet 0.70mm thick colour coated/ galvanised steel profiled deck.

G

G

Available Available

Up to

G

G

Typical Purlin Centres 1800 - 2100mm*** Minimum Roof Pitch 2 degrees (design pitch)

G

25yrs Yes Yes

* Based on test data utilising similar components ** Alternative insulation options - 145mm Rockwool DuoRock Roofing Board - 90mm thick Rigid PIR board. *** For increased span conditions, a wide range of profile sections and material thicknesses are available. Refer to page 32 for examples of profile availability. Further information and performance data can be downloaded from www.quedron.co.uk

G

9

BUILT UP SINGLE PLY

Built Up Insulated Structural Roof Deck Support System ­ 0.25 `U' Value

Q SYSTEM

SD 25

SYSTEM BENEFITS

G

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.25W/m2K

Offering the benefits of long span construction, enabling the design of lighter and therefore, more economic structures our structural deck system is specified for use within many high performance roof installations, typically supporting secretfix/standing seam outer skin roof products.

G

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>47dB AA

(Highest)

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 220mm thick Knauf Factoryclad 40 insulation quilt compressed to 205mm. ( = 0.040W/mK) 175mm deep Quedron Spacer System sat on 30mm deep top hat.

G

External Fire Exposure Classification

(BS476 Part 3)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

0

(Highest)

Insulation Non combustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

Spacer System

G

External Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

G

Design Flexibility/Bespoke systems Curved barrel vault option Ecological effect Sustainability / Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes Available Available

Up to

Vapour Control Layer Separate membrane or sealed side and end laps of deck section. Internal Sheet 0.75 ­ 1.50mm thick colour coated/ galvanised steel Quedron structural deck section. Typically 6000 - 10000mm >5 degrees ­ trapezoidal sections. >2.5 degrees ­ secret fix option.

G

G

G

G

G

Structural Support Centres Minimum design Roof Pitch

G

30yrs

Notes: Refer to page 32 for examples of profile availability. Further information and performance data can be downloaded from www.quedron.co.uk

G

Yes Yes

G

STRUCTURAL DECK

10

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Built Up Acoustic Structural Roof Deck Support System ­ 0.25 `U' Value

Q SYSTEM

AD 25

With similar structural benefits to our SD 25 system, the Acoustic Deck system incorporates a perforated deck and acoustic Rockwool mat overlay designed to allow internal reverberant sound to travel through the internal lining and be absorbed within the construction.

SYSTEM BENEFITS

G

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.25W/m2K

G

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>30dB 0.64*

(@500Hz)

G

Calculated Absorption Coefficient External Fire Exposure Classification

(BS476 Part 3)*

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 200mm thick Rockwool Cladding Roll insulation quilt compressed to 175mm. ( = 0.040W/mK) 175mm deep Quedron Spacer System.

G

AA

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

0

(Highest)

Insulation

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Class B

(2.1m centres)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

Spacer System

G

External Sheet Non-fragility Rating

Document ACR(M)001:2005 (Third Edition)

Vapour Control Layer Separate sealed membrane. Acoustic Layer 30mm thick Rockwool RW3 acoustic slab with 30mm deep top hat spacer to accept thermal spacer system. Optional Rockwool acoustic filler strips laid in profile corrugations. 0.75 ­ 1.50mm thick colour coated/galvanised steel Quedron structural deck section. Typically 6000 - 10000mm >5 degrees ­ trapezoidal sections. >2.5 degrees ­ secret fix option.

G

Design Flexibility/Bespoke systems Curved barrel vault option Ecological effect Sustainability / Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Available Yes Zero ODP Yes Available Available

Up to Notes: * Absorption coefficient based on 30% perforated open area Refer to page 32 for examples of profile availability. Further information and performance data can be downloaded from www.quedron.co.uk

G

G

G G

Internal Sheet

G

30yrs

G

Yes Yes

Structural Support Centres Minimum design Roof Pitch

G

11

ACOUSTIC DECK

design benefits

SPECIFICATION FLEXIBILITY

Available in a wide range of profile sections, materials, BBA certified coatings, BS and RAL colour options meeting the most stringent life expectancy, structural and aesthetic demands.

Wall Cladding systems

THERMAL PERFORMANCE

All Qsystems shown are Building Regulations Approved Document L2 compliant. However, bespoke systems tailored to suit individual client requirements can be easily accommodated by using deeper variants of our standard spacer system (0.20W/m2K) or our newly launched revolutionary `mast' system which gives the designer the potential to specify systems with `U' values in excess of 0.16W/m2K. All Qsystems can be specified in the knowledge that they offer thermal performance longevity for the life of the building.

ACOUSTIC PERFORMANCE

Excellent sound reduction performance; typically between 36 ­ 45dB (weighted S.R.I. Rw) - subject to system choice and product specification. Reduction and damping performance is typically between 5 - 15dB better than the equivalent foam cored composite panel construction. A 10dB reduction in acoustic terms will approximately halve the loudness. Further reduction by 10dB will halve the level again. Systems available with perforated internal linings provide excellent levels of sound absorption and contribute to lowered reverberation time.

FIRE RESISTANCE

Products contained within Qsystems can be deemed non-combustible in accordance with stringent British Standards. Fire wall systems available to BS476 Part 22, providing up to 4 hours integrity and meeting 15 or 30 minutes insulation criteria. No reliance is made on test methods laid out by other independent or associated bodies to claim performance ­ commonly undertaken with foam cored composite panel.

AIR PERMEABILITY

If installed to manufacturer's recommendations all Qsystems can easily achieve and significantly improve upon the 10m3/hr/m2 @ 50 Pa maximum air leakage stipulation as laid out within Building Regulations Approved Document L2 (2006).

(Further reading: Corus Technical Paper ­ Creating an air-tight building envelope. Refer to Quedron Technical Department or download at www.quedron.co.uk).

INSTALLATION

Logistically less demanding than composite panels due to their nestable nature, Quedron products take fewer lorries to deliver, use up far less site storage space and are easier and lighter to handle. Due to their flexibility, Qsystem sheets accept larger steelwork tolerances than rigid composite panels, thus preventing possible side lap sealing, end lap bearing and fastener stress problems.

SUSTAINABILITY

Products contained within Qsystems are recyclable with no additional greenhouse gases and do not present the potential ecological impact presented by foam cored composite panels.

(Further reading: Corus Technical Paper ­ End of life options for pre-finished steel buildings. Please consult our Technical Department or download at www.quedron.co.uk).

COST

Qsystems are economic, have good lifetime performance and do not present high disposal costs at the end of their life.

12

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Vertical Wall Cladding System with Glass Fibre Insulation ­ 0.35 `U' Value

Q SYSTEM VG 35

A lightweight, high quality and cost effective wall cladding system that combines ease of installation with typical ecological, non-combustibility and maintenance benefits over traditional PUR foam cored composite panels.

SPECIFICATION

External Sheet 0.50mm thick colour coated galvanised steel Quedron profiled sheet. 120mm thick Knauf Factoryclad 40 insulation quilt. ( = 0.040W/mK) 120mm deep Quedron Spacer System

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.35W/m2K

Insulation

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>36dB 0

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Spacer System

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Vapour Control Layer Lining Panel - Sealed side and end laps

G

Non combustible <10m3/hr/m2 @ 50 Pa Available Yes Zero ODP Yes Available Available

Up to

Air Permeability

(Building Regulations Approved Document L2 compliant)

Internal Sheet

0.40mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm

G

Design Flexibility/Bespoke systems Curved eaves option Ecological effect Sustainability / Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Typical Rail Centres

G

G

G

G

G

G

30yrs

G

Yes Yes

G

Note: Refer to page 28 for profile options and page 35 for profile specific system references and performance data.

13

VERTICAL THERMAL

Vertical Wall Cladding System with Rockwool Insulation ­ 0.35 `U' Value

Q SYSTEM VR 35

Combining similar benefits to our VG 35 system with even greater sound transmission performance, this construction is ideal for reducing the passage of noise pollution either into or from a contained environment.

SYSTEM BENEFITS

G

SPECIFICATION

2

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.35W/m K

External Sheet

0.70mm thick colour coated galvanised steel Quedron profiled sheet. 120mm thick Rockwool Cladding Roll insulation quilt. ( = 0.040W/mK) 120mm deep Quedron Spacer System.

G

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>43dB 0

(Highest)

Insulation

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Spacer System Non combustible <10m /hr/m @ 50 Pa Available Yes Zero ODP Yes Available Available

Up to

3 2

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

Vapour Control Layer Lining Panel - Sealed side and end laps Internal Sheet 0.70mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm

G

Design Flexibility/Bespoke systems Curved eaves options Ecological effect Sustainability / Recyclability NBS Specifications Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

G

Typical Rail Centres

G

G

G

G

G

30yrs

G

Yes Yes

G

Note: Refer to page 28 for profile options and page 35 for profile specific system references and performance data.

VERTICAL SOUND REDUCTION

14

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Acoustic Vertical Cladding System with Perforated Lining ­ 0.35 `U' Value

Q SYSTEM VA 35

By incorporating a perforated lining panel with loose mineral fibre insulation, this system offers the specifier all the thermal and design flexibility benefits of our other vertical systems but with greater sound absorbency performance, reducing the amount of reverberant sound reflected back off the internal lining surface.

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 100mm thick Rockwool Cladding Roll insulation quilt. ( = 0.040W/mK) 100mm deep Quedron Spacer System

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.35W/m2K

Insulation

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>29dB 0.40

(@500Hz)

G

Calculated Absorption Coefficient Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Spacer System

G

0

(Highest)

Vapour Control Layer Separate sealed membrane

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Acoustic Layer

30mm thick Rockwool RW3 acoustic slab ( = 0.034W/mK) with 50mm deep top hat spacer to accept thermal spacer system. 0.70mm thick colour coated galvanised steel fully perforated Quedron lining panel. (30% open area). 1100 - 1800mm

Non combustible <10m3/hr/m2 @ 50 Pa Available Yes Zero ODP Yes Available Available

Up to

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

Internal Sheet

G

Design Flexibility/Bespoke systems Curved eaves option Ecological effect Sustainability / Recyclability NBS Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

G

G

Typical Rail Centres

G

G

G

G

30yrs

G

Yes Yes

G

Note: Refer to page 28 for profile options and page 35 for profile specific system references and performance data.

15

VERTICAL SOUND ABSORPTION

Horizontal Wall Cladding System with Glass Fibre Insulation ­ 0.35 `U' Value

Q SYSTEM HG 35

Whilst offering the usual associated benefits of built up design over traditional composite panels, this highly flexible construction solution provides a combination of a clean vertical internal lining with aesthetically pleasing horizontal external cladding.

SYSTEM BENEFITS

G

SPECIFICATION

2

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

<0.35W/m K

External Sheet

0.70mm thick colour coated galvanised steel Quedron profiled sheet. 140mm thick Knauf Factoryclad 40 insulation quilt compressed to 135mm. ( = 0.040W/mK) 135mm deep Quedron `GP' Vertical Spacer System. Brackets at 1503mm maximum centres.

G

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>39dB 0

(Highest)

Insulation

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Available Yes Zero ODP Yes Available Available

Up to

Spacer System

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Design Flexibility/Bespoke systems Mitred corner options Ecological effect Sustainability / Recyclability NBS Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Vapour Control Layer Lining Panel - Sealed side and end laps. Internal Sheet 0.40mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm

G

G

G

Typical Rail Centres

G

G

G

30yrs

G

Yes Yes

G

Note: Refer to page 28 for profile options and page 36 for profile specific system references and performance data.

HORIZONTAL THERMAL

16

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

Horizontal Wall Cladding System with Rockwool Insulation ­ 0.35 `U' Value

Q SYSTEM HR 35

All the benefits of our HG 35 cladding system but with even better sound transmission characteristics. Available in a wide range of external profile options, colours and coatings this solution is ideal for use on prestigious public sector projects.

SPECIFICATION

External Sheet 0.70mm thick colour coated galvanised steel Quedron profiled sheet. 120mm thick Rockwool Flexi slab insulation. ( = 0.038W/mK) 135mm deep Quedron `Mast' Spacer System. Brackets at 1.67m maximum centres.

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.25W/m2K

Insulation

Calculated Average Sound Reduction

(weighted S.R.I Rw)

>44dB 0

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Spacer System

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Available Yes Zero ODP Yes Available Available

Up to

Vapour Control Layer Lining Panel - Sealed side and end laps. Internal Sheet 0.70mm thick colour coated galvanised steel Quedron lining panel. 1100 - 1800mm

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Design Flexibility/Bespoke systems Mitred corner options Ecological effect Sustainability / Recyclability NBS Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

G

Typical Rail Centres

G

G

G

G

G

30yrs

G

Yes Yes

G

Note: Refer to page 28 for profile options and page 36 for profile specific system references and performance data.

17

HORIZONTAL SOUND REDUCTION

introduction

In accordance with Building Regulations it may be necessary for specific elements of the building construction to have a stipulated period of fire resistance. Building Regulations Approved Document B (2000 Edition) provides guidelines on suitable forms of fire resistant structures encompassing construction, single element performance, means of escape and fire control. Categorised from B1 to B5, all of these requirements require integrated design evaluation to ensure effective compliance. Whilst all the conditions that come under consideration for fire performance cannot be included within this publication, the following summarised notes have been listed to help highlight the benefits of specifying Quedron built up profiled steel wall cladding systems. The following Building Regulations requirements are the most relevant when considering the use of steel cladding systems: Approved Document B2 - Internal Fire Spread (Linings) Requirement: Internal fire spread (linings) B2 (1) To inhibit the spread of fire within the building the internal linings shall (a) (b) resist the spread of flame over their surfaces; and have, if ignited, a rate of heat release which is reasonable in the circumstances. Requirement: Classification of Performance

Fire Wall Cladding systems

Building Regulations Approved Document B, Appendix A describes the different classes of performance and the appropriate methods of test. The main classifications used are based on tests to BS476: Parts 6 and 7. All Quedron supplied organic coated steel cladding products such as Plastisol, PVDF and Lining Enamel, when tested to the above standards have an index (I) not exceeding 12 and a sub-index (i1) not exceeding 6. As a result these products achieve a `Class 0' spread of flame rating in accordance with Building Regulations requirements (highest rating achievable). Approved Document B4 ­ External Fire Spread

External fire spread B4 (1) The external walls of the building shall resist the spread of fire over the walls and from one building to another, having regard to the height, use and position of the building. (b) The roof of the building shall resist the spread of fire over the roof and from one building to another, having regard to the use and position of the building.

External Surfaces The external surfaces of the walls should meet the provisions in Diagram 36, Requirement B4, Section 12. Using the same test methods as described for internal fire spread, all Quedron supplied organic coated steel cladding products will satisfy the highest achievable rating of `Class 0'. Please note that even if the above provisions have been met, buildings that are in excess of 15m above ground level require insulation of limited combustibility. Therefore, all insulation recommended for use within Qsystems achieve non-combustible classification when tested to BS476 Part 4. Fire Resistance Standard The external walls of the building should have the appropriate fire resistance given in Building Regulations Approved Document B, Table A1, Appendix A. This table covers specific provisions of test for fire resistance of elements of structure. Using BS476 Part 22 as the recommended test procedure for non-loadbearing elements, the table stipulates method of exposure, integrity and insulation periods, when positioned at a requisite distance from the relevant boundary. Building Regulations Approved Document B, Table A1 refers to Table A2 which stipulates the required period of fire resistance based upon building purpose, the height and whether sprinkler systems are to be incorporated. For example, an external non-loadbearing wall, not more than 18m high, positioned more than a metre from the relevant boundary, will require an integrity period of 90 minutes (non-sprinklered) and an insulation period of 15 minutes. To satisfy these Building Regulations requirements, Qsystem fire walls have been tested/assessed at approved fire research centres and will meet the following criteria.

SYSTEM TYPES

Qsystem Reference VGF 35 VRF 35 HRF 35 Orientation Vertical Vertical Horizontal Construction Type Outside Rail Outside Rail Outside Rail Fire Resistance Period 4 Hours 4 Hours 4 Hours Insulation Criteria 15 mins 15 & 30 mins 15 & 30 mins Exposure Inside Inside Inside Boundary Distance >1m >1m >1m

18

QUEDRON ROOFING & CLADDING PRODUCTS

QUEDRON ROOFING & CLADDING PRODUCTS

GENERAL CONSTRUCTION REQUIREMENTS

1) Position The external wall must be 1m or more from the relevant boundary (as measured from the outside face of the cladding construction). 2) Type of Building In accordance with regulation B2 of the Building Regulations it must be defined in Appendix A ­ Table A2. 3) Height Refer to Table A2, Appendix A, Part B of the Building Regulations. 4) Special Requirements by Local Authorities It may be that local interpretations of building regulations vary or that the building merits special consideration. It is essential that the building designer confirms that the Qsystem selected complies with the relevant local authority requirements. 5) Direction of Resistance Except for the internal partition fire wall (not shown in this brochure) Quedron fire wall systems are designed to resist fire from the inside of the building only. 6) Structural Frame The fire resistant system must be fixed to sheeting rails, which are fixed to supporting cleats through slotted holes with a bolt incorporating a plastic or low melt washer. Both elements have the purpose of assisting movement through thermal expansion in the event of a fire. The rails are to be at maximum centres of 2000mm. All sheeting rails need to be single span and need to be shorter than standard to allow for expansion. The remainder of the frame must be protected by suitable material which gives the same period of protection as the wall itself. 7) Support When the sheeting rails heat up during a fire they will no longer function as a structural member due to loss of strength (usually at 550 degrees celsius). To prevent the wall moving downwards under its own weight, either a support at the base, or a protected eaves beam is required. The intention is that the inclusion of at least one of these features will support the wall during a fire.

BS476 Part 4: Non-Combustibility Test for Materials All insulation products recommended for use within Qsystems achieve `non-combustible' classification in accordance with this standard and therefore meet the requirements contained within Approved Document B4. BS476 Part 6: Methods of Test for Fire Propagation for Products This test ascertains the contribution a material has upon a fire by assessing the rate of heat release over a 20 minute period. Calculated from empirical formula given within the standard, this contribution is expressed as an index of performance (I) together with sub-indices i1, i2 and i3 which relate to heat contribution over shorter time periods. BS476 Part 7: Methods for Classification of the Surface Spread of Flame of Products Materials are graded 1 to 4 according to the rate of flame spread across their surface. Class 1 is the highest grade offering the best resistance to surface spread. The Building Regulations have a higher Class 0 designation which combines the results of BS476 Parts 6 and 7. BS476 Part 22: Methods for Determination of the Fire Resistance of Non-Loadbearing Elements of Construction This test is designed to assess the performance of complete elements when exposed to fire on one or both faces of the wall construction. These elements should remain stable, resist penetration of flame, hot gases and limit the transfer of heat from one side to the other. Two criteria are given to confirm the fire resistance period for a nonload bearing wall construction. Integrity: The period a system satisfactorily prevents the passage of flames and hot gases in accordance with the test procedures. Insulation: Following the performance criteria within the standard and using designated `non-combustible' elements only, the period of time they must restrict the transmittance of heat from the fire source to the unexposed face of the wall construction.

BRITISH STANDARD 476

BS476 is the recognised standard referred to within the Building Regulations. This standard outlines the necessary procedures to obtain test related measurements that help define the fire performance of single elements or complete constructions. Parts relevant to Qsystem products/constructions are highlighted as follows:BS476 Part 3: External Fire Exposure Roof Test Roofs classifications are given according to the resistance period they offer when subjected to external fire exposure (e.g. from an adjacent building or compartment). Building Regulations stipulate that pitched roofs produced from organic coated steel will achieve Classification AA ­ the highest designation possible. Note: This standard has been withdrawn. However, the relevant test method appears in the annex of BS5427: 1996 Code of Practice for the use of Profiled Sheet for Roof and Wall Cladding on Buildings and continues to be cited within the Building Regulations.

19

FIRE WALL

QUEDRON ROOFING & CLADDING PRODUCTS

4 Hour Fire Rated Vertical Wall Cladding System (Glass Fibre) - 0.35 `U' Value

SPECIFICATION

WFRC No. 141194 AR INTERNAL FIRE ASSESSMENT BS476 Part 22:1987 compliant Stability - 240 minutes Integrity - 240 minutes Insulation - 15 minutes

Note: Refer to page 28 for profile options and page 37 for profile specific system references and performance data.

VERTICAL FIRE WALL

20

Q SYSTEM

VGF 35

VERTICAL FIRE WALL

This system has been designed for use as a non-load bearing external fire wall situated at least 1 metre away from a relevant boundary. Secured outside rail the construction incorporates glass fibre insulation and satisfies the criteria for 4 hours integrity (15 mins insulation) when assessed to comply with BS476 Part 22: 1987 in relation to internal fire exposure and installed in accordance with Approved Document B (Fire Spread) Building Regulations 2000.

CONSTRUCTION NOTES

Structural Frame To be protected using suitable materials providing a fire resistance period equal to the cladding system. Support cladding from suitable structural element, e.g: Fire rated eaves beam. Supplied in shorter lengths than normal with slotted holes to facilitate expansion. Install in single span condition using 16mm diameter steel bolts with steel and plastic washers. Rail centres for cladding span not to exceed 2m. To meet 15 minute insulation period, stitch lining panel side laps at 450mm centres using steel rivets. e.g: TSPD 44 BS or equivalent. Lining Panel - Seal side and end laps. Compress between outer sheet and front face of spacer bar. Corofil C144 Fire wall filler laid vertically every 20 metres. Stitch side laps at 450mm centres using 6.3mm diameter steel self drilling screws.

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.35W/m2K

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>42dB 0

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Cladding Rails

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Available Zero ODP Yes Available Available Available

Up to

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Design Flexibility/Bespoke systems Ecological effect Sustainability / Recyclability NBS Specifications CAD Construction Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Internal Lining

G

G

G

G

Vapour Control Layer Insulation Cavity Barrier

(Building Regulations Requirement)

G

G

30yrs

G

Yes Yes

G

External Cladding

4 Hour Fire Rated Vertical Wall Cladding System (Glass Fibre) - 0.35 `U' Value

QUEDRON ROOFING & CLADDING PRODUCTS

21

QUEDRON ROOFING & CLADDING PRODUCTS

4 Hour Fire Rated Vertical Wall Cladding System (Rockwool) - 0.35 `U' Value

SPECIFICATION

WFRC No. 141175 AR INTERNAL FIRE ASSESSMENT BS476 Part 22:1987 compliant Stability - 240 minutes Integrity - 240 minutes Insulation - 15 or 30 minute options

Note: Refer to page 28 for profile options and page 37 for profile specific system references and performance data.

VERTICAL FIRE WALL

22

Q SYSTEM

VRF 35

VERTICAL FIRE WALL

This system has been designed for use as a non-load bearing external fire wall situated at least 1 metre away from a relevant boundary. Secured outside rail the construction incorporates Rockwool insulation and satisfies the criteria for 4 hours integrity (15 or 30 mins insulation) when assessed to comply with BS476 Part 22: 1987 in relation to internal fire exposure and installed in accordance with Approved Document B (Fire Spread) Building Regulations 2000.

CONSTRUCTION NOTES

Structural Frame To be protected using suitable materials providing a fire resistance period equal to the cladding system. Support cladding from suitable structural element, e.g: Fire rated eaves beam. Supplied in shorter lengths than normal with slotted holes to facilitate expansion. Install in single span condition using 16mm diameter steel bolts with steel and plastic washers. Rail centres for cladding span not to exceed 2m. To meet 30 minute insulation period, stitch lining panel side laps at 300mm centres using steel rivets. e.g: TSPD 44 BS or equivalent. Lining Panel - Seal side and end laps. Compress between lining panel and reverse face of spacer bar. Where deemed necessary stitch side laps using 6.3mm diameter steel self drilling screws.

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.35W/m2K

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>38dB 0

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Cladding Rails

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Available Zero ODP Yes Available Available Available

Up to

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Design Flexibility/Bespoke systems Ecological effect Sustainability / Recyclability NBS Specifications CAD Construction Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Internal Lining

G

G

G

G

Vapour Control Layer Insulation External Cladding

G

G

30yrs

G

Yes Yes

G

4 Hour Fire Rated Vertical Wall Cladding System (Rockwool) - 0.35 `U' Value

QUEDRON ROOFING & CLADDING PRODUCTS

23

QUEDRON ROOFING & CLADDING PRODUCTS

4 Hour Fire Rated Horizontal Wall Cladding System (Rockwool) - 0.35 `U' Value

147 135

SPECIFICATION

LINING PANEL 0.40/0.70mm Quedron colour coated galvanised steel pro led sheet.

INSULATION 120mm thick Rockwool Flexislab friction tted between lining panel

FIRE SIDE

and back face of Eurobar Extra rails. (0.038W/mk Lambda value).

SPACER SYSTEM 135mm deep Quedron 'Mast' spacer bar and bracket system, installed vertically with brackets positioned at at 2m max centres (subject to wind load conditions).

CLADDING RAIL Cladding rails supplied by others. (See construction notes)

THERMAL BREAK 12mm thick Rockwool thermal barrier strip bonded to rail. EXTERNAL CLADDING 0.70mm Quedron colour coated galvanised steel pro led sheet.

WFRC No. 159671 AR INTERNAL FIRE ASSESSMENT BS476 Part 22:1987 compliant Stability - 240 minutes Integrity - 240 minutes Insulation - 15 or 30 minute options

Note: Refer to page 28 for profile options and page 37 for profile specific system references and performance data.

HORIZONTAL FIRE WALL

24

Q SYSTEM

HRF 35

HORIZONTAL FIRE WALL

This horizontal cladding system has been designed for use as a non-load bearing external fire wall situated at least 1 metre away from a relevant boundary. Secured outside rail the construction incorporates Rockwool insulation and satisfies the criteria for 4 hours integrity (15 or 30 mins insulation) when assessed to comply with BS476 Part 22: 1987 in relation to internal fire exposure and installed in accordance with Approved Document B (Fire Spread) Building Regulations 2000.

CONSTRUCTION NOTES

Structural Frame To be protected using suitable materials providing a fire resistance period equal to the cladding system. Support cladding from suitable structural element, e.g: Fire rated eaves beam. Supplied in shorter lengths than normal with slotted holes to facilitate expansion. Install in single span condition using 16mm diameter steel bolts with steel and plastic washers. Rail centres for vertical lining not to exceed 2m. To meet 30 minute insulation period, stitch lining panel side laps at 300mm centres using steel rivets. e.g: TSPD 44 BS or equivalent. Lining Panel - Seal side and end laps. Friction fit between lining panel and back face of spacer bar. Install horizontally as per normal recommendations. Secure to cladding via spacer bracket fasteners. Stitch to spacer bar using 2No. nonwashered 5.5mm diameter steel self drilling screws.

G

SYSTEM BENEFITS

Thermal Transmittance

(Building Regulations Approved Document L2 compliant)

G

<0.35W/m2K

Calculated Average Sound Reduction

(weighed S.R.I Rw)

>41dB 0

(Highest)

G

Internal Fire Spread Classification

(Building Regulations Approved Document B2, BS476 Parts 6 and 7)

Cladding Rails

G

Insulation Non-Combustibility Test

(BS476 Part 4, Building Regulations Approved Document B4)

Non combustible <10m3/hr/m2 @ 50 Pa Available Zero ODP Yes Available Available Available

Up to

G

Air Permeability

(Building Regulations Approved Document L2 compliant)

G

Design Flexibility/Bespoke systems Ecological effect Sustainability / Recyclability NBS Specifications CAD Construction Specification Profile CAD blocks Material warranty Recommended ancillary suppliers Recommended Installers

Internal Lining

G

G

G

G

Vapour Control Layer Insulation External Cladding Base Support Bracket

G

G

30yrs

G

Yes Yes

G

4 Hour Fire Rated Horizontal Wall Cladding System (Rockwool) - 0.35 `U' Value

QUEDRON ROOFING & CLADDING PRODUCTS

25

profile selector

EXTERNAL ROOF CLADDING

DESIGN FLEXIBILITY

Quedron single skin roof profiles allow the designer the flexibility to choose from a range of aesthetically pleasing sections and then incorporate them into Qsystem designs tailored to meet specific air tightness, thermal transmission, fire, sound reduction and recyclability performance criteria.

QUEDRON ROOFING & CLADDING PRODUCTS

Q CLAD

C

MW5R

32

200 PITCH

132 1000 COVER WIDTH

68

23

C

Denotes external face

LOAD/SPAN

The table opposite has been produced to give an indication of product span capability. The span performance differs subject to the profile's section properties, application and applied load criteria. For the purpose of this publication the following criteria has been applied. Roof - 1.20kN/m2 Dead & super imposed load 1.50kN/m Line load L/200 Deflection limit. Subject to satisfactory installation, fastener type and frequency, all products should withstand similar negative wind loading to the above positive loading criteria. Whilst the above loadings are likely to satisfy a large percentage of typical projects, for cases outside the above, please consult our Technical Department. Note: The spans highlighted may need to be reduced (max 2.1m) to ensure non-fragility status in accordance with ACR(M)001:2005 (Third Edition) or (max 1.8m) to suit structural capability and non-fragility status of the lining panel.

Q CLAD

C

MW5RS

32

200 PITCH

132 1000 COVER WIDTH

68

23

C

Denotes external face

Q CLAD

C

1000/32R

32

166.67 PITCH

72.67 1000 COVER WIDTH

94

23

C

Denotes external face

MATERIAL AVAILABILITY

Abbreviations shown within the table opposite highlight our extensive range of standard materials and BBA certified coatings. Further materials, gauges, colours and coatings are available, subject to quantity requirements and extended lead times. The legend is as follows:Al St Pl Pr Prm Ac Acm Aluminium Steel HPS200, Dobel 200XT Plastisol Non-metallic Prisma, PVDF coated steel Metallic Prisma, PVDF coated steel Non-metallic ARS, PVDF coated aluminium Metallic ARS, PVDF coated aluminium

C

Q CLAD

32

1000/32R SP

166.67 PITCH

72.67 1000 COVER WIDTH

94

23

C

Denotes external face

Q CLAD

C 38

WA6

152.4 PITCH 914.4 COVER WIDTH

82

70.4

19

C

Denotes external face

Q CLAD

C

QSF500

54 432 500 COVER WIDTH

C Denotes external face

26

53

EXTERNAL ROOF CLADDING

CURVING DATA

The information below relates to both factory curve and site self curve capabilities. Factory data has been based on a single convex curve. Further guidance should be sought from our Technical Department if concave or wave curves etc., are a design requirement. Self curving induces stress marking in the sheet, becoming more visible the tighter the radius. Therefore, the figures illustrated for minimum self curve capability are based on Quedron's perception as to what would be aesthetically acceptable. Basic recommendations when self curving sheet on site are:i) ii) iii) Use long sheet lengths to reduce end laps. Reduce purlin centres, allowing a greater concentration of fixings and reducing the stress effect on each individual support. Place EPDM tape across the top flange of the support. This can help prevent pressure marking that can be caused by the resisting support edge.

FIRE RATING

All Quedron roof cladding sections achieve a Class 1 Surface Spread of Flame Rating when tested to BS476 Parts 6 and 7 and meet Class 0 requirements as laid out within current Building Regulations.

INSTALLATION

Design loadings and profile pitch will dictate fastener frequency. General installation information, specific to each profile, is available. For further information please consult our Technical Department.

EXTERNAL ROOF CLADDING TABLE

Profile Material Gauge (mm) Weight 2 (kg/m ) Single Span (mm) Multi Span (mm) Minimum Factory Curve (mm) 350 Minimum Self Curve (m) Minimum Pitch Maximum Length (mm)

MW5R

St Al

0.70 0.90 0.70 0.90 0.70 0.90 0.70 0.90 0.70 0.90 0.70

6.75 3.02 6.75 3.02 6.75 3.02 6.75 3.02 7.38 3.30 7.74

1900 1400 1900 1400 2000 1500 2000 1500 2000 1700 1800

2000 1700 2000 1700 2300 1800 2300 1800 2500 2000 1800

40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

MW5RS

St Al

350

40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

1000/32R*

St Al

350

40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

1000/32R Special

St Al

350

40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

WA6

St Al

350

45(Pl),55(Pr),60(Prm) 45(Ac),50(Acm)

12000

QSF500

St

N/A

85(Pl),90(Pr),95(Prm)

2.5°**

24000***

* Unsuitable for use with rooflights. ** 2.5° recommended minimum design pitch (1° actual minimum). *** On site rolling facilities available for longer sheet lengths.

27

QUEDRON ROOFING & CLADDING PRODUCTS

profile selector

EXTERNAL WALL CLADDING

AESTHETIC FLEXIBILITY

Quedron offers an attractive range of standard wall cladding profiles. These sections are typically installed with the profile broad flange facing outermost, thus creating an aesthetically pleasing `flush' finish. However, if required, the flexible nature of these sections allows the profile to be reversed for a more `pronounced' appearance. Please refer to the External Roof Cladding Selector for availability.

QUEDRON ROOFING & CLADDING PRODUCTS

Q CLAD

C

MW5C

32

200 PITCH

132 1000 COVER WIDTH

68

23

C

Denotes external face

LOAD/SPAN

The table opposite has been produced to give an indication of product span capability. The span performance differs subject to the profile's section properties, application and applied load criteria. For the purpose of this publication the following criteria has been applied. 1.00kN/m Positive wind load L/150 Deflection limit.

C

C

Q CLAD

32

MW5CS

200 PITCH

132 1000 COVER WIDTH

68

23

C

Denotes external face

2

Q CLAD

32

1000/32C

Subject to satisfactory installation, fastener type and frequency, all products should withstand similar negative wind loading to the above positive loading criteria. Whilst the above loadings are likely to satisfy a large percentage of typical projects, for cases outside the above, please consult our Technical Department.

166.67 PITCH

72.67 1000 COVER WIDTH

94

23

C

Denotes external face

Q CLAD

C 38

WA6M

MATERIAL AVAILABILITY

Abbreviations shown within the table opposite highlight our extensive range of standard materials and BBA certified coatings. Further materials, gauges, colours and coatings are available to special order, subject to quantity requirements and extended lead times. The legend is as follows:Al St Pl Pr Prm Ac Acm Aluminium Steel HPS200, Dobel 200XT Plastisol Non-metallic Prisma, PVDF coated steel Metallic Prisma, PVDF coated steel Non-metallic ARS, PVDF coated aluminium Metallic ARS, PVDF coated aluminium

C

152.4 PITCH

70.4 914.4 COVER WIDTH

82

19

C

Denotes external face

Q CLAD

C

QSF500

54 432 500 COVER WIDTH

C Denotes external face

53

Q CLAD

20

1067/20C

CURVING DATA

The information opposite relates to both factory curve and site self curve capabilities. Factory data has been based on a single convex curve. Further guidance should be sought from our Technical Department if concave or wave curves etc., are a design requirement. Self curving induces stress marking in the sheet, becoming more visible the tighter the radius. Therefore, the figures illustrated for minimum self curve capability are based on Quedron's perception as to what would be aesthetically acceptable. Basic recommendations when self curving sheet on site are:i) ii) Use long sheet lengths to reduce end laps. Reduce rail centres, allowing a greater concentration of fixings and reducing the stress effect on each individual support. Place EPDM tape across the outer support flange. This can help prevent pressure marking that can be caused by the resisting support edge.

19

152.4 PITCH 96.4 1066.8 COVER WIDTH 56 56

C

Denotes external face

Q CLAD

C

50

930/50HR

186 PITCH

157 930 COVER WIDTH

29

R86.6

C

Denotes external face

Q CLAD

C

QR131/2/3

iii)

76.2 PITCH 990.6 COVER WIDTH

R23

C Denotes external face

28

EXTERNAL WALL CLADDING

ORIENTATION

Profile design dictates orientation suitability. The table below illustrates which Quedron sections are best laid vertical, horizontal or suitable for both applications. 0.50mm thick steel sections are perfectly acceptable for vertical applications. However, experience shows that when installing horizontal sheeting a minimum gauge of 0.70mm should be used.

FIRE RATING

All Quedron wall cladding sections achieve a Class 1 Surface Spread of Flame Rating when tested to BS476 Parts 6 and 7 and meet Class 0 requirements as laid out within current Building Regulations.

INSTALLATION

Design loadings and profile pitch will dictate fastener frequency. General installation information, specific to each profile, is available. For further information please consult our Technical Department.

EXTERNAL WALL CLADDING TABLE

Profile Material Gauge (mm) Weight (kg/m2) Single Span (mm) Multi Span (mm) Minimum Factory Curve (mm) 350 Minimum Self Curve (m) Orientation Maximum Length (mm)

MW5C

St Al

0.70 0.90 0.50 0.70

6.75 3.02 4.82 6.75 3.02 4.82 6.75 3.02 5.27 7.38 3.30 7.74 4.52 6.33 2.83 7.00 6.82

1900 1500 1700 2000 1500 1800 2100 1700 2000 2400 1900 1900 1400 1700 1300 3000 1300

2300 1800 2000 2400 1800 2100 2400 2000 2400 2800 2300 1900 1700 2000 1600 3600 1600

40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

V V V V/H V/H V V/H V/H V V/H V/H V V V/H V/H V/H V/H

12000

MW5CS

St

350

N/A 40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

Al 1000/32C St

0.90 0.50 0.70

350

N/A 40(Pl),50(Pr),55(Prm) 40(Ac),45(Acm)

12000

Al WA6M St

0.90 0.50 0.70

350

N/A 45(Pl),55(Pr),60(Pm) 45(Ac),50(Acm)

12000

Al QSF500 1067/20C St St

0.90 0.70 0.50 0.70

N/A 350

85(Pl),90(Pr),95(Prm) N/A 40(Pl),50(Pr),55(Prm) 45(Ac),50(Acm)

24000 12000

Al 930/50HR* QR131/2/3 St St

0.90 0.70 0.70

N/A See note**

N/A 30(Pl),40(Pr),45(Prm)

12000 6500

*1000mm cover width version available **This product is available factory curved. Please consult our Technical Department for production capabilities.

29

QUEDRON ROOFING & CLADDING PRODUCTS

profile selector

INTERNAL LINING PANELS

MODULAR DESIGN

Quedron's range of internal lining panels has been specifically developed with product integration in mind. Installed cover widths of these sections match those of our external cladding range and where design dictates, allows the use of our modular rooflights. To assist, the table opposite indicates which internal profiles are suitable with each available lining panel.

QUEDRON ROOFING & CLADDING PRODUCTS

Q CLAD

19 166.6 PITCH C 1000 COVER WIDTH 103.7

QLP19/1000

62.9 22 C Denotes soffit side

LOAD/SPAN

In roofing applications, typical span capacities are generally dictated by the product's self weight and their capacity to support the weight of the insulation. Experience has shown, that under typical conditions, a 0.40mm thick steel lining panel will satisfactorily double span 2m in both roof and wall situations. However, on roof applications the spans highlighted may need to be reduced to 1.8m to ensure non-fragility status in accordance with ACR(M)001:2005 (Third Edition).

19

Q CLAD

166.6 PITCH C 1000 COVER WIDTH 103.7

QLP19/1000P

62.9 22 C Denotes soffit side

Q CLAD

19

QLP19S/1000

MATERIAL AVAILABILITY

Internal lining requirements tend to dictate bright, light reflective, smooth surfaces. Therefore, to accommodate this, our standard specification is Bright White Lining Enamel. However, to cope with aggressive environments, further materials, gauges, colours and coatings are available to special order, subject to quantity requirements and extended lead times. Abbreviations shown within the table opposite have been produced to highlight the range of standard materials and BBA certified coatings. The legend is as follows:St Pl Le Pr Prm Steel HPS200, Dobel 200XT Plastisol Lining Enamel Non-metallic Prisma, PVDF Metallic Prisma, PVDF

166.6 PITCH

103.7 C 1000 COVER WIDTH

62.9 22 C Denotes soffit side

Q CLAD

19

QLP19/1000R

166.6 PITCH

C

103.7 1000 COVER WIDTH

62.9 22 C Denotes soffit side

Q CLAD

QLP19S/1000R

19

166.6 PITCH

C

103.7 1000 COVER WIDTH

62.9 22 C Denotes soffit side

CURVING DATA

The information opposite relates to both factory curve and site self curve capabilities. Factory data has been based on a single convex curve. Further guidance should be sought from our Technical Department if concave or wave curves etc., are a design requirement. Self curving induces stress marking in the sheet, becoming more visible the tighter the radius. Therefore, the figures illustrated for minimum self curve capability are based on Quedron's perception as to what would be aesthetically acceptable.

20

152.4 PITCH C

Q CLAD

96.4 914.4 COVER WIDTH 56

QLP20/914

56

C

Denotes soffit side

Q CLAD

32

QLP32/5

NO STIFFENERS

200 PITCH

132 C

68

23

AIR PERMEABILITY

Quedron lining panel side and end laps can be easily sealed to provide a vapour check and meet the air tightness requirements laid out in the current Building Regulations.

1000 COVER WIDTH

C Denotes soffit side

Q CLAD

32

QLP32/5S

ACOUSTICS

Quedron's lining panel portfolio includes a purpose designed perforated section. Whilst still offering the same benefits as the solid counterpart, this profile allows sound to travel through a percentage of the normally reflective surface. Therefore, when used within Qsystems that incorporate acoustic insulation, such as RA25 and VA 35, excellent levels of sound absorbency can be achieved.

200 PITCH

132 C

68

23

1000 COVER WIDTH

C Denotes soffit side

Q CLAD

38

WA6M

152.4 PITCH

82

70.4

19

C

914.4 COVER WIDTH

C Denotes soffit side

30

INTERNAL LINING PANELS

FIRE RATING

All Quedron lining panels achieve a Class 1 Surface Spread of Flame Rating when tested to BS476 Parts 6 and 7 and meet Class 0 requirements as laid out within current Building regulations.

INSTALLATION

Installation recommendations to ensure non-fragility status are held within our Technical Department and available for download at www.quedron.co.uk.

INTERNAL LINING PANEL TABLE

Profile Material Gauge (mm) Weight (kg/m2) Single Span (mm) Multi Span (mm) Nonfragility Rating Minimum Factory Curve (mm) QLP19/1000 St 0.40 0.70 3.50 6.12 1500 1600 2000 2200 C(1.8m) B(2.1m) 350 Minimum Self Curve (m) 35(Le) 6000 MW5R(S) MW5C(S) 1000/32R 1000/32C QLP19/1000 Perforated St 0.70 4.28 1500 2000 C(1.8m) 350 35(Le) 6000 MW5R(S) MW5C(S) 1000/32R 1000/32C QLP19S/1000 St 0.40 0.70 3.50 6.12 1500 1600 2000 2200 C(1.8m) B(2.1m) 350 35(Le) 6000 MW5R(S) MW5C(S) 1000/32R 1000/32C QLP19/1000 Reverse St 0.40 0.70 3.50 6.12 1500 1600 2000 2200 C(1.8m) B(2.1m) 350 35(Le) 6000 MW5R(S) MW5C(S) 1000/32R 1000/32C QLP19S/1000 Reverse St 0.40 0.70 3.50 6.12 1500 1600 2000 2200 C(1.8m) B(2.1m) 350 35 (Le) 35(Pl), 35(Pr), 40(Prm) QLP20/914 St 0.40 3.52 1500 2000 C(1.8m) 350 35(Le) 6000 6000 MW5R(S) MW5C(S) 1000/32R 1000/32C WA6 WA6M QLP32/5 St 0.70 6.75 2000 2400 B(2.1m) 350 35 (Le) 35(Pl), 35(Pr), 40(Prm) QLP32/5S St 0.70 6.75 2000 2400 B(2.1m) 350 35 (Le) 35(Pl), 35(Pr), 40(Prm) WA6M St 0.70 6.75 2200 2600 B(2.1m) 350 35 (Le) 35(Pl), 35(Pr), 40(Prm)

QUEDRON ROOFING & CLADDING PRODUCTS

Maximum Length (mm)

Modular Outer Sheet

12000

MW5R(S) MW5C(S) 1000/32R 1000/32C

12000

MW5R(S) MW5C(S) 1000/32R 1000/32C

12000

WA6 WA6M

31

profile selector

ROOF DECKING

DESIGN FLEXIBILITY

Quedron Qdeck sections have been designed to support specialist single ply roof membrane systems or act as long span transverse structural lining support for secret fix roof cladding products.

QUEDRON ROOFING & CLADDING PRODUCTS

Q DECK

32

QD32/1000

166.7 PITCH

C

72.7 1000

94

23

COVER WIDTH

C

Denotes soffit side

LOAD/SPAN

The table opposite has been produced to give an indication of product span capability. The span performance differs subject to the profile's section properties, application and applied load criteria. For the purpose of this publication the following criteria has been applied. Deck- 1.50kN/m2 Dead & super imposed load 1.50kN/m Line load L/250 Deflection limit. Subject to satisfactory installation, fastener type and frequency, all products should withstand similar negative wind loading to the above positive loading criteria. Whilst the above loadings are likely to satisfy a large percentage of typical projects, for cases outside the above, please consult our Technical Department.

Q DECK

32

QD32S/1000

166.7 PITCH

C

72.7 1000

94

23

COVER WIDTH

C

Denotes soffit side

Q DECK

38

QD38/914

152.4 PITCH

C

70.4 914.4

82

19

COVER WIDTH

C

Denotes soffit side

PROFILE & MATERIAL AVAILABILITY

For the purpose of this brochure, the more typical profile sections and gauges have been illustrated. However, further sections and gauges are available as standard and can be found within our Qdeck Product Selector brochure. Abbreviations shown within the adjacent table highlight our extensive range of standard materials and BBA certified coatings. Additional materials, non-standard gauges, colours and coatings are available, subject to quantity requirements and extended lead times. The legend is as follows:St Pl Pr Prm Steel HPS200, Dobel 200XT Plastisol Non-metallic Prisma, PVDF, Polyester Metallic Prisma, PVDF

48.5

Q DECK

QD50/1000

250 PITCH

135

115 1000 COVER WIDTH

54

C

C

Denotes soffit side

Q DECK

83

QD85/1120

C

280 PITCH

119

161 1120 COVER WIDTH

C

40

Denotes soffit side

Q DECK

102.6

QD100/825

FIRE RATING

All Quedron deck sections achieve a Class 1 Surface Spread of Flame Rating when tested to BS476 Parts 6 and 7 and meet Class 0 requirements as laid out within current Building Regulations.

C

275 PITCH

139 825 COVER WIDTH

136

39

C

Denotes soffit side

Q DECK

137

QD140/930

C

310 PITCH

144 930 COVER WIDTH

166

43

C

Denotes soffit side

Q DECK

QD160/750

158

C

250 PITCH

119 750

131

41

COVER WIDTH

C

Denotes soffit side

32

ROOF DECKING

ACOUSTICS

Whilst not shown within this brochure, Quedron's decking portfolio also includes purpose designed perforated sections. Still offering the same benefits as their solid counterparts, these decks allow sound to travel through a percentage of their normally reflective surface. Therefore, when used in conjunction with materials that have absorbent qualities such as rock fibre insulation, systems can be created that offer excellent levels of sound absorbency. e.g. Qsystem AD25. For further information please consult our Technical Department.

INSTALLATION

Design loadings and profile pitch will dictate fastener frequency. General installation guides, specific to each profile, are available. For further information please consult our Technical Department or visit www.quedron.co.uk.

ROOF DECKING TABLE

Profile Material Gauge (mm) Weight 2 (kg/m ) Single Span (mm) Double Span (mm) Multi Span (mm) Recommended Support Bearing (mm)* QD32/1000 QD32S/1000 QD38/914 QD50/1000 QD85/1120 QD100/825 QD140/930 St St St St St St St St St QD160/750 St St St 0.70 0.70 0.70 0.75 0.75 0.75 0.75 1.00 1.50 0.75 1.25 1.50 6.75 6.75 7.38 7.50 8.03 9.10 9.74 13.00 19.50 12.10 16.10 24.20 1600 2000 1800 2500 3400 4200 5100 5600 6000 5800 6100 7000 2200 2400 2300 2400 3800 4200 4700 6600 8000 5600 7800 9400 1900 2300 2100 2700 4000 4700 5200 6200 7100 6300 7200 8000 160 24000** 50 50 50 65 100 100 160 12000 12000 12000 13500 13500 13500 24000** Maximum Length (mm)

* Reduced bearing widths may be acceptable, subject to web crushing strength of the section. ** For logistical and site handling reasons it may be more practical to design the deeper structural decks as single spanning sections. Please contact our Technical Department to discuss your particular project requirements.

33

QUEDRON ROOFING & CLADDING PRODUCTS

ROOF CLADDING SYSTEMS THERMAL

System Reference RG 25.1 (74) Outer Sheet MW5R(S)* 0.70mm Steel 1000/32R 0.70mm Steel WA6 0.70mm Steel QSF500 0.70mm Steel Spacer System 170mm Eurobar 170mm Eurobar 170mm Eurobar 180mm Eurobar

QSYSTEM RG 25 ­ (0.25W/m2K `U' VALUE)

Insulation Quilt 180mm Knauf Factoryclad 40 ( =0.040W/mK) 180mm Knauf Factoryclad 40 ( =0.040W/mK) 180mm Knauf Factoryclad 40 ( =0.040W/mK) 180mm Knauf Factoryclad 40 ( =0.040W/mK) Lining Panel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP20/914 0.40mm Steel QLP19/1000 0.40mm Steel Non-fragility Rating Class B Outer Sheet Class C Lining Panel Class B Outer Sheet Class C Lining Panel Class B Outer Sheet Class C Lining Panel Class B Outer Sheet Class C Lining Panel Calculated Sound Reduction (Rw) 41.7dB

RG 25.2 (74)

41.9dB

RG 25.3 (74)

42.6dB

RG 25.4 (74)

42.4dB

Note: (S)* = Available option with stiffening swages in the broad pan.

SOUND REDUCTION

System Reference RR 25.1 (77b) Outer Sheet MW5R(S)* 0.70mm Steel 1000/32R 0.70mm Steel WA6 0.70mm Steel QSF500 0.70mm Steel Spacer System 180mm Eurobar 180mm Eurobar 180mm Eurobar 180mm Eurobar

QSYSTEM RR 25 ­ (0.25W/m2K `U' VALUE)

Insulation Quilt 180mm Rockwool Cladding Roll ( =0.040W/mK) 180mm Rockwool Cladding Roll ( =0.040W/mK) 180mm Rockwool Cladding Roll ( =0.040W/mK) 180mm Rockwool Cladding Roll ( =0.040W/mK) Lining Panel QLP32/5(S)* 0.70mm Steel QLP32/5(S)* 0.70mm Steel WA6M 0.70mm Steel QLP32/5(S)* 0.70mm Steel Non-fragility Rating Class B Outer Sheet Class B Lining Panel Class B Outer Sheet Class B Lining Panel Class B Outer Sheet Class B Lining Panel Class B Outer Sheet Class B Lining Panel Calculated Sound Reduction (Rw) 47.8dB

RR 25.2 (77b)

47.9dB

RR 25.3 (77b)

49.0dB

RR 25.4 (77b)

48.0dB

Note: (S)* = Available option with stiffening swages in the broad pan.

SOUND ABSORPTION

System Reference RA 25.1 (77a) Outer Sheet MW5R(S)* 0.70mm Steel Spacer System 150mm Eurobar + 50mm Top Hat

QSYSTEM RA 25 ­ (0.25W/m2K `U' VALUE)

Insulation Quilt 150mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 150mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 150mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 150mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) Lining Panel QLP19/1000 0.70mm Steel Fully perforated (30% open area) Non-fragility Rating Class B Outer Sheet Class C Lining Panel Sound Reduction 30.2dB Abs Coef @500Hz 0.55

RA 25.2 (77a)

1000/32R 0.70mm Steel

150mm Eurobar + 50mm Top Hat

QLP19/1000 0.70mm Steel Fully perforated (30% open area)

Class B Outer Sheet Class C Lining Panel

30.4dB

0.55

RA 25.3 (77a)

WA6 0.70mm Steel

150mm Eurobar + 50mm Top Hat

QLP20/914 0.70mm Steel Fully perforated (30% open area)

Class B Outer Sheet Class C Lining Panel

30.6dB

0.55

RA 25.4 (77a)

QSF500 0.70mm Steel

150mm Eurobar + 50mm Top Hat

QLP19/1000 0.70mm Steel Fully perforated (30% open area)

Class B Outer Sheet Class C Lining Panel

30.1dB

0.55

Note: (S)* = Available option with stiffening swages in broad pan.

34

VERTICAL WALL CLADDING SYSTEMS THERMAL

System Reference VG 35.1 (54) Outer Sheet MW5CS** 0.50mm Steel 1000/32C 0.50mm Steel WA6M 0.50mm Steel

QSYSTEM VG 35 ­ (0.35W/m2K `U' VALUE)

Spacer System 120mm Eurobar 120mm Eurobar 120mm Eurobar Insulation Quilt 120mm Knauf Factoryclad 40 ( =0.040W/mK) 120mm Knauf Factoryclad 40 ( =0.040W/mK) 120mm Knauf Factoryclad 40 ( =0.040W/mK) Lining Panel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel Calculated Sound Reduction (Rw) 36.8dB

VG 35.2 (54)

37.0dB

VG 35.3 (54)

37.9dB

Note: ** Supplied with stiffening swages in broad pan.

SOUND REDUCTION

System Reference VR 35.1 (77a) Outer Sheet MW5C(S)* 0.70mm Steel 1000/32C 0.70mm Steel WA6M 0.70mm Steel QSF500 0.70mm Steel

QSYSTEM VR 35 ­ (0.35W/m2K `U' VALUE)

Spacer System 120mm Eurobar 120mm Eurobar 120mm Eurobar 120mm Eurobar Insulation Quilt 120mm Rockwool Cladding Roll ( =0.040W/mK) 120mm Rockwool Cladding Roll ( =0.040W/mK) 120mm Rockwool Cladding Roll ( =0.040W/mK) 120mm Rockwool Cladding Roll ( =0.040W/mK) Lining Panel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel Calculated Sound Reduction (Rw) 43.9dB

VR 35.2 (77a)

44.1dB

VR 35.3 (77a)

44.9dB

VR 35.4 (77a)

44.1dB

Note: (S)* = Available option with stiffening swages in broad pan.

SOUND ABSORPTION

System Reference VA 35.1 (77a) Outer Sheet MW5C(S)* 0.70mm Steel Spacer System 100mm Eurobar + 50mm Top Hat

QSYSTEM VA 35 ­ (0.35W/m2K `U' VALUE)

Insulation Quilt 100mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 100mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 100mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) 100mm Rockwool Cladding Roll ( =0.040W/mK) + 30mm Rockwool RW3 Acoustic Slab ( =0.034W/mK) Lining Panel QLP19/1000 0.70mm Steel Fully perforated (30% open area) Sound Reduction 29.4dB Abs Coef @500Hz 0.40

VA 35.2 (77a)

1000/32C 0.70mm Steel

100mm Eurobar + 50mm Top Hat

QLP19/1000 0.70mm Steel Fully perforated (30% open area)

29.6dB

0.40

VA 35.3 (77a)

WA6M 0.70mm Steel

100mm Eurobar + 50mm Top Hat

QLP19/1000 0.40mm Steel Fully perforated (30% open area)

29.7dB

0.40

VA 35.4 (77a)

QSF500 0.70mm Steel

100mm Eurobar + 50mm Top Hat

QLP19/1000 0.40mm Steel Fully perforated (30% open area)

29.4dB

0.40

Note: (S)* = Available option with stiffening swages in broad pan.

QUEDRON ROOFING & CLADDING PRODUCTS

35

HORIZONTAL WALL CLADDING SYSTEMS THERMAL

System Reference HG 35.1 (74) Outer Sheet MW5CS* 0.70mm Steel 1000/32C 0.70mm Steel WA6M 0.70mm Steel QSF500 0.70mm Steel 1067/20C 0.70mm Steel 930/50HR** 0.70mm Steel

QSYSTEM HG 35 ­ (0.35W/m2K `U' VALUE)

Vertical Spacer System 135mm GP Spacer System 135mm GP Spacer System 135mm GP Spacer System 135mm GP Spacer System 135mm GP Spacer System 135mm GP Spacer System Insulation Quilt 140mm Knauf Factoryclad 40 ( =0.040W/mK) 140mm Knauf Factoryclad 40 ( =0.040W/mK) 140mm Knauf Factoryclad 40 ( =0.040W/mK) 140mm Knauf Factoryclad 40 ( =0.040W/mK) 140mm Knauf Factoryclad 40 ( =0.040W/mK) 140mm Knauf Factoryclad 40 ( =0.040W/mK) Lining Panel Calculated Sound Reduction (Rw) 39.8dB

QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel

HG 35.2 (74)

40.0dB

HG 35.3 (74)

40.8dB

HG 35.4 (74)

40.0dB

HG 35.5 (74)

39.3dB

HG 35.6 (74)

39.6dB

Notes: Cladding rail centres 1800mm Vertical spacer centres 1503mm * Supplied with stiffening swages in broad pan. ** 1000mm cover width version available.

SOUND REDUCTION

System Reference HR 35.1 (77a) Outer Sheet MW5CS* 0.70mm Steel 1000/32C 0.70mm Steel WA6M 0.70mm Steel QSF500 0.70mm Steel 1067/20C 0.70mm Steel 930/50HR** 0.70mm Steel

QSYSTEM HR 35 ­ (0.35W/m2K `U' VALUE)

Vertical Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System Insulation Quilt 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) Lining Panel Calculated Sound Reduction (Rw) 45.0dB

QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel QLP19/1000 0.70mm Steel

HR 35.2 (77a)

45.2dB

HR 35.3 (77a)

46.0dB

HR 35.4 (77a)

45.2dB

HR 35.5 (77a)

44.4dB

HR 35.6 (77a)

44.6dB

Notes: Cladding rail centres 1800mm Vertical spacer centres 1670mm * Supplied with stiffening swages in broad pan. ** 1000mm cover width version available.

36

VERTICAL FIRE WALL SYSTEMS QSYSTEM VGF 35 ­ USING GLASS FIBRE (0.35W/m2K `U' VALUE)

System Reference VGF 35.1 - 40 (74) Outer Sheet MW5C(S)* 0.70mm Steel 1000/32C 0.70mm Steel WA6M 0.70mm Steel Spacer System 200mm Eurobar 200mm Eurobar 200mm Eurobar Insulation Quilt 160mm Knauf Factoryclad 40 ( =0.040W/mK) 160mm Knauf Factoryclad 40 ( =0.040W/mK) 160mm Knauf Factoryclad 40 ( =0.040W/mK) Lining Panel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel Calculated Sound Reduction (Rw) 42.5dB

VGF 35.2 - 40 (74)

42.7dB

VGF 35.3 - 40 (74)

43.5dB

Notes: Due to quilt compression between spacer bar and outer sheet we do not recommend the use of 0.50mm material. (S)* = Available option with stiffening swages in the broad pan.

QSYSTEM VRF 35 ­ USING ROCK FIBRE (0.35W/m2K `U' VALUE)

System Reference VRF 35.1 (54) Outer Sheet MW5CS* 0.50mm Steel 1000/32C 0.50mm Steel WA6M 0.50mm Steel Spacer System 120mm Eurobar 120mm Eurobar 120mm Eurobar Insulation Quilt 120mm Rockwool Cladding Roll ( =0.040W/mK) 120mm Rockwool Cladding Roll ( =0.040W/mK) 120mm Rockwool Cladding Roll ( =0.040W/mK) Lining Panel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel Calculated Sound Reduction (Rw) 38.2dB

VRF 35.2 (54)

38.4dB

VRF 35.3 (54)

39.3dB

Notes: * Supplied with stiffening swages in the broad pan.

HORIZONTAL FIRE WALL SYSTEMS QSYSTEM HRF 35 ­ USING ROCKWOOL FLEXISLAB (0.35W/m2K `U' VALUE)

System Reference HRF 35.1-38 (74) Outer Sheet MW5CS* 0.70mm Steel 1000/32C 0.70mm Steel WA6M 0.70mm Steel QSF500 0.70mm Steel 1067/20C 0.70mm Steel 930/50HR** 0.70mm Steel Vertical Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System 135mm Mast Spacer System Insulation Quilt 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) 120mm Rockwool Flexislab ( =0.038W/mK) Lining Panel Calculated Sound Reduction (Rw) 41.6dB

QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel QLP19/1000 0.40mm Steel

HRF 35.2-38 (74)

41.8dB

HRF 35.3-38 (74)

42.7dB

HRF 35.4-38 (74)

41.9dB

HRF 35.5-38 (74)

41.0dB

HRF 35.6-38 (74)

41.2dB

Notes: Cladding rail centres 1800mm Vertical spacer centres 1670mm * Supplied with stiffening swages in broad pan. * * 1000mm cover width version available.

37

QUEDRON ROOFING & CLADDING PRODUCTS

TECHNICAL SERVICES

QUEDRON ROOFING & CLADDING PRODUCTS

Attractive high quality building in-depth technical support.

LITERATURE SUITE

Full in-depth and informative brochures are constantly evolving, helping to resolve product selection issues and highlighting our total package portfolio covering cladding systems, rooflights, rainwater products, louvres and solar shading, to bull noses, soffit systems and bespoke flashing fabrications.

THERMAL MODELLING

All Qsystems shown are Building Regulation Approved Document L2 compliant. However, bespoke `U' values, tailored to suit individual client requirements, can be accommodated using industry standard three dimensional thermal modelling software.

ACOUSTIC ANALYSIS STRUCTURAL CALCULATIONS

Span tables calculated in accordance with BS5950 Part 6 highlighting positive and negative load capacity are readily available for our range of profiles. Where specific design loadings are known, in-house structural calculation software can be utilised to offer bespoke project calculation checks and confirm suitability of the chosen profile. Using computer programme prediction software specially developed by the Department of Applied Acoustics at Salford University, Quedron is able to assist in the analysis of bespoke systems. This enables quick multiple calculation results to be obtained, thus preventing the need for expensive, complicated and time consuming test programmes. Acoustic prediction reports relating to our standard system range can be obtained through our Technical Department.

38

solutions fully backed with

AIR PERMEABILITY

Detailed advice can be given as to how Qsystems easily achieve and significantly improve upon the 10m3/hr/m2 @ 50 Pa maximum air leakage stipulation laid out within Building Regulations Approved Document L2 (2006).

CONSTRUCTION ADVICE

As a long standing member of the MCRMA, our experienced Technical Team can offer a vast range of advice, backed by official test data and recognised publications, covering topics such as noncombustible construction, non-fragility performance, robust flashing details, installation good practice etc.

For further information please contact our Technical Department or download at www.quedron.co.uk.

NBS SPECIFICATIONS

A full suite of NBS format specifications has been created to cover the 150 plus possible variants to the generic Qsystems highlighted within this brochure. A specification service is also available to cover bespoke systems that incorporate Quedron products.

CLADDING

DECKING

ROOFLIGHTS

FABRICATIONS

Quedron Ltd has taken great care to ensure that the technical advice contained within this publication is accurate. However, no responsibility is assumed for errors or misinterpretation resulting from the information contained within. Quedron Ltd reserves the right to change details and specifications without prior notice.

39

QUEDRON ROOFING & CLADDING PRODUCTS

ROOF CLADDING SYSTEMS

ROOF DECKING SYSTEMS

WALL CLADDING SYSTEMS

FIRE WALL CLADDING SYSTEMS

T F E W

01242 241222 01242 584934 [email protected] www.quedron.co.uk

Designed and Produced by SEL Ltd. Birmingham.

Quedron Limited Runnings Road Kingsditch Trading Estate Cheltenham Gloucestershire GL51 9NQ

Information

Qdeck Brochure FINAL

40 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

143269


You might also be interested in

BETA
Qdeck Brochure FINAL