Read 20101692_LO_r1.pdf text version

packer penetrator systems for use with electrical submersible pumps (ESP). QCI is proud of delivering quality, on-time products that meet our customers' requirements. We have over 20 years of oil field experience installing our systems worldwide with a track record of excellence and reliability. QCI electrical penetrator systems eliminate the need for cable splicing, saving hours of costly rig time, and increasing reliability by reducing exposure to reactive agents. QCI offers various types of wellhead penetrator systems designed to work with a variety of applications to meet customer requirements and needs. QCI wellhead penetrator systems can be designed to fit new or existing wellheads (concentric or non-concentric applications), or to accommodate wellhead applications that were not originally designed for use with ESP applications. QCI wellhead penetrators can be easily retrofitted to replace existing competitor type mandrel penetrator systems. QCI also offers specialty penetrator systems for applications requiring the use of BOP Cans, ESP Packers, dual or triple completions, and heater applications. These applications can also be retrofitted to replace existing competitor systems. All of the QCI penetrator systems are suitable for 375°F/ 190°C, and can be fitted to all ESP pump cables and electrical requirements currently in use (up to 5000 Volts and 257Amps). QCI operates under the ISO 9001-2000 requirements. All of the QCI wellhead penetrator systems are third party approved by Factory Mutual (FM) and CSA. The QCI products are designed to meet the highest classifications for safety compliance within the United States for operation of electrical equipment in hazardous/explosive locations (Class I, Divisions 1 & 2). We pride ourselves on quick delivery and excellent engineering support. QCI provides on-site installation (domestic and international) and can provide technical support through highly trained international representatives. Complete in-house training simulating wellhead and packer penetrator installation can be provided for customers who wish to install QCI equipment. Training videos and installation procedures are available upon request.

Quick Connectors Incorporated (QCI) is a leading provider of wellhead and

QCI - About Us

CI ­Unique Adaptable Global

1

P3000-2

P3000-2 Wellhead Penetrator System "Boll Weevil Type"

P3000-2 Mini Mandrel Canned Pump Coupling (CPC) Surface Conduit System Breather Vent/Detonation Arrestor

Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Designed to eliminate large mandrel type penetrators. Available as a P3000-2F for flat cable. ESP cable is stripped and the three cable wires are separated and sealed off with an elastomer sealing element. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the power supply. Permits the use of shielded and non-shielded cable.

Specifications

FM & CSA Approved Voltage: Dependant on Max. Rating of ESP Cable Amperage: Dependant on Max. Rating of ESP Cable Pressure: 5,000 psi API WP (13,500 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

2

P3000-2F Wellhead Penetrator System "Seal Sub" Type

Flat-to-Round Transition Collar P3000-2 Mini Mandrel Canned Pump Coupling (CPC) Surface Conduit System

Breather Vent/Detonation Arrestor Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Designed to eliminate large mandrel type penetrators. Available as a P3000-2 for round cable. ESP cable is stripped and the three cable wires are separated and sealed off with an elastomer sealing element. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the power supply. Permits the use of shielded and non-shielded cable.

Specifications

FM & CSA Approved Voltage: Dependant on Max. Rating of ESP Cable Amperage: Dependant on Max. Rating of ESP Cable Pressure: 5,000 psi API WP (13,500 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

P3000-2F

3

P3000-2DM

Upper Pigtail (Competitor) Mandrel (Competitor) Lower Pigtail (Competitor)

P3000-2DM Wellhead Penetrator System

QCI Dummy Mandrel (Replaces items 1-3) P3000-2 Mini Mandrel

Canned Pump Coupling (CPC) Surface Conduit System Breather Vent/Detonation Arrestor Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Available as a P3000-2FDM for flat cable. ESP cable is stripped and the three cable wires are separated and sealed off with an elastomer sealing element. A QCI dummy mandrel is provided to fit the existing wellhead, replacing the competitor's mandrel. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the power supply. Permits the use of shielded and non-shielded cable.

Specifications

FM & CSA Approved Voltage: Dependant on Max. Rating of ESP Cable Amperage: Dependant on Max. Rating of ESP Cable Pressure: 5,000 psi API WP (13,500 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

4

)

P3000-1 Wellhead Penetrator System

Flat-to-Round Transition Collar Feed-thru Assembly Bottom Seal Fittings Canned Pump Coupling (CPC) Bracket Assembly Surface Conduit System

Surface Splice Boot Ground Wire Connector Breather Vent/Detonation Arrestor Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Adaptable with either concentric or eccentric wellhead completions, and can be run in small annular spaced wells. Three flexible fittings with Swagelok connections seal off the penetrator above and below the tubing hanger. ESP cable is stripped and the three cable wires are separated and sealed off with an elastomer sealing element. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for a required length to reach the power supply. Permits the use of shielded and non-shielded cable.

Specifications

FM & CSA Approved Voltage: Dependant on Max. Rating of ESP Cable Amperage: Dependant on Max. Rating of ESP Cable Pressure: 3,000 psi API WP (6,000 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

P3000-1 P3000-1FR

5

P5000 Model 1

P5000 - Model 1 Wellhead Penetrator System

Triskelion Male & Female Connectors Bottom Seal Fittings Bracket Assembly Canned Pump Coupling (CPC)

Surface Conduit System Breather Vent/Detonation Arrestor Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Adaptable for concentric wellhead completions, and can be installed in small annular spaced wells. Three flexible fittings with Swagelok connections seal off the penetrator above and below the tubing hanger. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the motor control panel. Permits the use of shielded and non-shielded cable.

Specifications

FM & CSA Approved Voltage: 5000 VAC, 3 Phase Amperage: 150 Amp and 190 Amp versions available Pressure: 5,000 psi API WP (13,500 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

6

P5000 Dual ESP Wellhead Penetrator System

Triskelion Male & Female Connectors Bottom Seal Fittings Bracket Assembly Canned Pump Coupling (CPC) Surface Conduit System

Breather Vent/Detonation Arrestor Cable Gland Surface Power Cable (CLX)

Features/Benefits

Eliminates cable splices in the wellbore. Adaptable for concentric wellhead completions, and can be installed in small annular spaced wells. Three flexible fittings with Swagelok connections seal off the penetrator above and below the tubing hanger. Reusable surface conduit system suitable for hazardous locations. UL listed surface cable (CLX) is terminated and sealed in the conduit system for required length to reach the motor control panel. Permits the use of shielded and non-shielded cables.

Specifications

FM & CSA Approved Voltage: 5000 VAC, 3 Phase Amperage: 150 Amp and 190 Amp versions available Pressure: 5,000 psi API WP (13,500 psi Proof Test) Temp: 375° F, 190° C Hazardous Area: Class I, Divisions 1 & 2 Group D

P5000-Dual ESP

7

Packer Penetrator Systems

Manifold Bushing Examples

Standard 3-Hole

Multiple Ports for Additional Control Lines

Multiple Port Type Packer

Dual String Type Packer

ESP cable Triskelion Lower Male & Female Connectors Seal Fittings

Manifold Bushing Male & Female Connectors Triskelion Upper

Features/Specifications

No splices above and below the packer. A mainfold bushing is provided for dual string packers, and can accommodate extra ports for control lines, if necessary. For small diameter and multiple port packers, the penetrators pass through 3 individual ports through the packer. Voltage: 5000 VAC, 3 Phase

8

Amperage: 150 Amp and 257 Amp versions available

Multiple Port Type Packer

Dual String Type Packer

Pressure: 5,000 psi API WP (10,000 psi Proof Test) Temp: 375° F, 190° C