Sony EVI-HD1 Robotic Camera

Cable Connections

· The Sony EVI-HD1 Robotic Camera connects to the switcher either through an RS-422 to RS-232 converter to the Editor port on the back of the switcher, or through a Comtrol DeviceMaster to the switcher over ethernet.

Switcher Setup

To Set Up Communications

1. Press MENU Config. 2. Press Add. 3. Use the Slot knob to select the port or slot you want to use.

DeviceMaster

5 2

SYSTEM

NEXT

NEXT

Device

DeviceMaster Cable Connections

· Serial Interface Cable (DB9 to MiniDIN) (Figure 1).

1 2 3 4 5 6 4 3 1 7 8

· Select Slot X, where X is the number of the slot you want to use. · Select SP.

6 7 8 9

RS-422/232 Converter

To DeviceMaster

(male cable end)

To Device

(male cable end)

4. Use the Type knob to select Camera. 5. Press NEXT. 6. Use the SubType knob to select sony_1.0. 7. Press NEXT.

a. Use the Field knob to select the segment of the DeviceMaster IP address you want to edit. DeviceMaster b. c. d. e. Use the Value knob to select the number. Press NEXT. Use the Option knob to select Port. Use the Value knob to select the port on the DeviceMaster that the EVI-HD1 is connected to.

Figure 1 DB9 to MiniDIN

Table 1 Serial Cable Connections

DeviceMaster (Serial Port)

2 (Rx) 3 (Tx) 5 (Gnd)

Robotic Camera (VISCA IN Port)

3 (Tx) 5 (Rx) 4 (Gnd)

RS-422/232 Converter Cable Connections

· Serial Interface Cable (DB9 to MiniDIN) (Figure 2).

1 2 3 4 5 6 4 3 RS-422/232 Converter 1 7 8 5 2

a. Use the Option knob to select Baud. RS-422/232 Converter b. Use the Value knob to select 38400. c. Use the Option knob to select Parity. d. Use the Value knob to select NONE.

6 7 8 9

8. Press Option. 9. Press Confrm.

To Switcher

(male cable end)

To Device

(male cable end)

Figure 2 DB9 to MiniDIN

To Set Up Video Inputs

1. Press MENU CONFIG Input NEXT. 2. Use the Input knob to select the video input BNC that the Robotic Camera is connected to. 3. Press Device. 4. Use the Device knob to select the EVI-HD1 that is connected to the selected input BNC. 5. Press NEXT. 6. Use the Option knob to select Channel. 7. Use the Value knob to select the channel, or address, that the specific camera head you want to control is on. 8. Set the additional options for the camera as follows:

Table 2 RS-422/232 Converter Cable Connection

CrossOver (Editor Port)

2 (TxA) 3 (RxB) 5 (Gnd) 7 (TxB) 8 (RxA) RS-422/232 Converter

Robotic Camera (VISCA IN Port)

3 (Tx) 5 (Rx) 4 (Gnd)

FlexDeviceTM Installation

The FlexDevice driver for this device has been included in the current software release (v3.1).

Option

Invert Tilt Invert Pan

Value

No (default) No (default)

Phone: +1 613-652-4886 · Technical Support: +1 613-652-4886 · www.rossvideo.com · 4999DR-130-01

147

9. Press Option. 10. Press Confrm.

VISCA Out

2 (DSR) 3 (Tx) 4 (Gnd) 5 (Rx)

VISCA In

1 (DTR) 5 (Rx) 4 (Gnd) 3 (Tx)

DeviceMaster Setup

Refer to the documentation that came with the DeviceMaster for information on using the Comtrol® PortVision® software to set up the DeviceMaster. Use the following information to set up your DeviceMaster: · You must use a Static IP address for the DeviceMaster. You need to enter this address into the switcher so that it can connect to the DeviceMaster. · You must set up each serial port on the DeviceMaster for the device you are connecting to it. Ensure the following is set up on the Comtrol PortVision software: > Serial Configuration -- Use the following information.

Transmission Standard Baud Parity Data Bits Stop Bits

Compatibility

Robotic Camera

Sony EVI-HD1 Robotic Camera

Version

--

Switcher

CrossOver 3.1

FlexDevice

RS-232 38400 NONE 8 1 Focus Focus Mode Iris Iris Mode Pan Recall Shot Store Shot Tilt FlexDevice Core Sony Flex Cam Driver 1.0 1.0

Features

Robotic Camera Feature Support

> TCP Connection Configuration -- For each serial port on the DeviceMaster, ensure that Enable and Listen are checked and enter a port number for the serial port. Ross Video suggests that you start numbering the ports at 1001. Leave all other setting at their default values. > UDP Connection Configuration -- For each serial port on the EVI-HD1, ensure that Enable Serial to Ethernet, Enable Ethernet to Serial, and Enable Ethernet Receive from any IP address are unchecked. Leave all other setting at their default values.

RS-422/232 Converter Setup

Refer to the documentation that came with your converter for proper setup information.

Zoom

Trademarks

All third-party product names and any registered and unregistered trademarks mentioned in this document are used for identification purposes only and remain the exclusive property of their respective owners.

Robotic Camera Setup

The jumpers on the EVI-HD1 that is connected to the switcher must be set as follows: Jumper

1 2 3 4

Value

Infra-red signal control (OFF) disables the control Set to ON for 38400 baud rate No connection No connection

If you are daisy chaining multiple Sony EVI-HD1 Robotic Cameras together, use the following pinouts to connect the one camera to the next. VISCA Out

1 (DTR)

VISCA In

2 (DSR)

148

© 2011 Ross Video Limited. All rights reserved. Contents of this publication may not be reproduced in any form without the written permission of Ross Video Limited. Contents of this document are subject to change without notice. Printed in Canada.

Information

Robo-Cam_Sony EVIHD1 (CPS)(4999DR-130-01).fm

2 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

299595


You might also be interested in

BETA
Robo-Cam_Sony EVIHD1 (CPS)(4999DR-130-01).fm