3.4

Paving type D: Parks Decomposed granite

General overview + specifications

Locations : Parks + open space corridors Material/ product · Decomposed granite/crushed sandstone Installation/ construction · 100mm depth compacted decomposed granite on cement stabilised consolidated FCR · 100mm crushed sandstone cement stabilised as required. · Max. fall across footpath 2% · Design to specialist engineer's specification Maintenance · Maintain depths and regrade as required. · Ensure paths are located with adequate clearance from flooding zones and minimal gradient variations.

01- Decomposed granite path Plan 1:25

02- Decomposed granite path Section 1:25

PAVING TYPE D: PARKS

Macquarie Park Public Domain Technical Manual Design Intent Only Rev. E February 2008

Hardworks

3.4

53

3.5

Kerb + Gutter Insitu concrete kerb Insitu concrete gutter

General overview + specifications

Locations : All new streets Note All corners to have 25 radius. Compression strength of concrete to be not less than 25 MPa at 28 days. Installation/ construction: · To Council's specification. 01- Typical concrete insitu kerb and gutter Section 1:10

KERB AND GUTTER

Macquarie Park Public Domain Technical Manual Design Intent Only Rev. E February 2008

Hardworks

3.5

54

3.6

Tactile indicators

General overview + specifications

Locations : As required in accordance with AS1428.4 and DDA Material/ product · Solid 316 stainless steel - CF-SS-Black discreet Units/ sizes/ format · 26mm diameter stainless steel. Luminance contrast to comply with AS1428.4 Installation/ construction · To comply with AS1428.4 and DDA · Fixed to substrate surface, Maintenance · Maintenance to manufacturer's requirements. Manufacturer's details: DTAC Pty Ltd Ph: (03) 9553 1799 Fax: (03) 9553 1833

01- Tactile indicators Section 1:5

02- Tactile indicators Plan 1:5

TACTILE INDICATORS

Macquarie Park Public Domain Technical Manual Design Intent Only Rev. E February 2008

Hardworks

3.6

55

3.7

Typical retaining wall: Adjacent to footpath

General overview + specifications

Locations : As required Material/ product · Insitu concrete/precast concrete face. Finish · Ensure high quality finish: class 2. 01- Typical retaining wall: Type 1 Section 1:20 Installation/ construction · To engineer's requirements · Where possible, align retaining walls perpendicular to street edge. · Where possible, allow for planting to edge of footpath (type 2)

02- Typical retaining wall: Type 1 Plan 1:20

01- Typical retaining wall: Type 2 Section 1:20

02- Typical retaining wall: Type 2 Plan 1:20

RETAINING WALL TYPE A

Macquarie Park Public Domain Technical Manual Design Intent Only Rev. E February 2008

Hardworks

3.7

56