Read SUNPUS_E11A.indd text version

HYBRID UPS

E11A

1

SANUPS E11A

HYBRID UPS

120V model

Input/Output Output capacity

NETWORK

MONITORING MONITORIN MONITORING Mountable

EIA

19

inch rack

AC120V Single-phase

208V model

Input/Output

1kVA

0.7kW

1.5kVA

1.05kW

2kVA

1.4kW

3kVA

2.1kW

Output capacity

AC208V Single-phase

1kVA

0.7kW

2kVA

1.4kW

3kVA

2.1kW

The advancement of technology has increased the demand for quality power. In a perfect world, commercial power would always be stable and normal, however, we live in a world in which electricity from local utilities typically experiences anomalies such as spikes, surges, electrical noise, load fluctuations, and outages. To protect your investments in technology equipment from these problems, informed users rely on SANYO DENKI SANUPS E11A products to resolve these power issues and provide continuous, clean power to connected equipment. Not only does the SANYO DENKI SANUPS E11A create continuous and clean power, it is an intelligent device in which power is consumed only when power conditions are unfavorable, making the unit highly efficient. The SANYO DENKI SANUPS E11A Hybrid UPS provide highly efficient power protection to everything from heavy machinery and manufacturing devices to complex server systems and sensitive communication equipment (Voice and Data). With over 40 years of UPS experience, SANYO DENKI ensures the superior quality of the SANUPS E11A Hybrid UPS and provides the product equipped with extra long life batteries and a 3 year warranty. The SANUPS E11A Hybrid UPS - a product truly in a class of its own.

Hybrid UPS-Energy conservation Self battery check feature UPS management Software

Mounted in a 19-inch rack Includes metal brackets for 19 inch rack installation. Rack support rail is optional. Vertical Installation Includes vertical stand for upright support.

2

Hybrid UPS-Energy conservation

SANYO DENKI combines both line interactive and double conversion UPS technologies in the SANUPS E11A Hybrid UPS, delivering Conversion 3 modes of operation for high efficiency and reliability. Efficiency Conversion efficiency of the SANUPS E11A is increased by 4%* compared to comparable online UPS.

95%

Commercial Power Load Device

SANUPS E11A

* It is a result of comparing the performances with existing 1kVA UPS of our company.

The Hybrid type SANUPS E11A automatically selects the most efficient mode of operation for any given power condition. Operating mode can be manually chosen and locked by the end user.

Three different modes of operation:

When power conditions are good.

ECONOMY mode Hybrid Method

SANUPS E11A

ACTIVE FILTER mode

Harmonic noise

When load power fluctuates.

DOUBLE CONVERSION mode When power conditions fluctuate.

Momentary blackout

Voltage fluctuation

Suppresses high frequencies generated by load and improves power factor.

Frequency fluctuation

Harmonic noise

Self battery check feature

The SANUPS E11A automatically performs regular battery tests for operation during a power outage, and maintains peak battery conditions for reliable operation during an actual power outage.

* The frequency of the battery test is open to configuration. (Test frequency choices are 1, 3 and 6 months; the factory setting is 6 months.) * A LAN interface card (optional) is necessary to transmit the battery test results to the user's PC.

Begin Testing

Normal Operation

Load Device Commercial Power Commercial Power

Battery Test

Load Device

Rectifier

Inverter

Rectifier

Inverter

Periodic Check

Battery

Battery

Return to Normal Operations

* If a decline in the battery function is detected during test mode, normal operation will resume.

3

UPS management Software

To increase user control over equipment protection, our standalone Windows compatible UPS Management Software "SANUPS SOFTWARE STANDALONE" is provided as a standard accessory. Use it to improve the utility of the UPS, through useful functions such as monitoring UPS performance over a network connection and configuring shutdown settings.

OS

Windows 2000 Windows XP Windows Server 2003

Options

UPS control software

SANUPS SOFTWARE

Shuts down the system automatically and stops UPS. Smooth power supply control is ensured for one-to-one connection, one UPS for one computer, as well as connection with multiple computers. Also, control of the power supply and automatic operation of the computer using the schedule function can be carried out.

OS

for Windows

Windows 2000 Windows XP Windows XP Professional x64 Edition Windows Vista Windows Server 2003 Windows Server 2003 x64 Edition

for Linux

Red Hat Enterprise Linux v.3 (x86 / AMD64 / Intel EM64T) Red Hat Enterprise Linux v.4 (x86 / AMD64 / Intel EM64T) SUSE Linux Enterprise Server 9 (x86 / AMD64 / Intel EM64T) Turbolinux 10 Server (x86 / AMD64 / Intel EM64T)

for Windows for Multiple OS*

PMS40B00E without cable PMS41B00E without cable

Note: Corresponds to all left OS.

for UNIX

Solaris 8, 9, 10 (SPARC) AIX 5.1, 5.2, 5.3 HP-UX 11i (PA-RISC / Itanium2)

UPS option

LAN interface card

This product has been developed to connect our UPS "SANUPS" directly with LAN*. This device makes it possible to monitor the power supply and report results, and therefore reaction to irregularities in the power supply can be made quickly. It can be arranged so that any trouble in the power supply is reported to the system manager by e-mail.

*LAN: Local Area Network

Model: PRE11A01-US

4

Example of use of the SANUPS software

Pattern 1 Serial dry contact signal connection 1

For backing up a single personal computer with a UPS with a serial port or a UPS with contact output.

Operable without network environment. It can be used for a firewall.

RS-232C Power source

SANUPS SOFTWARE STANDALONE or SANUPS SOFTWARE

Dry contact signal connection cannot be used for SANUPS SOFTWARE STANDALONE.

Pattern 2

Serial/dry contact signal connection 2

For backing up multiple personal computers with a UPS with a serial port or a UPS with contact output.

A low-cost UPS control system can be realized.

Caution: If the personal computer connected with a UPS with serial contact signal connection is not in operation, monitoring or control of other personal computers cannot be performed.

RS-232C or Dry contact signal Power source Telnet log in

SANUPS SOFTWARE

SANUPS SOFTWARE

No need for software

It can be used for an OS with which SANUPS software is not compatible. Caution: Login by SSH or Telnet must be possible. "UNIX and Linux"

Pattern 3

Serial/dry contact signal connection 3

For backing up Sun Fire of Sun Microsystems mid-range server or higher with a UPS.

Shuts down Sun Fire reliably.

(Domain shutdown Domain Power OFF SC Power OFF/shutdown Console PC shutdown UPS stop)

Console PC

LAN

Telnet log in Sun Fire

SANUPS SOFTWARE

RS-232C or Dry contact signal Power source

SC Domain A Domain B

Pattern 4

LAN connection 1

For backing up multiple personal computers/workstations with a UPS in which a LAN interface card (optional) is incorporated.

Applicable to a clustering system. Remote ON/OFF control is possible.

Power source

LAN interface card

SSH*/ Telnet log in

No need for software

SANUPS SOFTWARE

SANUPS SOFTWARE

It can be used for an OS with which SANUPS software is not compatible. Caution: Login by SSH or Telnet must be possible. "UNIX and Linux"

*SSH: "SSH" is an abbreviation of "Secure SHell".

Pattern 5

LAN connection 2

For backing up a blade server with a UPS in which a LAN interface card optional is incorporated.

Up to 50 blade can be shut down.

LAN

LAN interface card

Blade server

Power source Install SANUPS software on each blade.

5

Front

Battery Power Low LED

Alarm LED Inverter Switch Battery Test Switch Clear Switch Input LED Output LED Supply Mode LED Load Level Display

Option Card Slot

Back

120V / 1kVA standard model shown here.

PC Interface

UPS Output

Option Card Interface Input Cable (1.8m / 5.91ft)

Expansion model

EPO, Systematic Control Contact Point

Power Switch (ON/OFF) External Battery Connection Port

PC Interface

Option Card Interface

Remote Interface

Interface & INPUT/OUTPUT Connection Chart

Output (kVA) 120V model 1 Model PC Remote (RS-232C) Standard Expansion Standard Expansion Standard Expansion Standard Expansion Standard Expansion Standard Expansion Standard Expansion

NEMA L5-30P

IEC60320-C14 Qty(1)IEC60320-C14 to NEMA L6-20P line cord option included.

EPO*

Dry Contact signal Systematic LAN Interface Card Interface Card Control (Option) (Option) Contact Model: PRE11A01-US Model: PRE11A02-US

INPUT Plug / Receptacle

OUTPUT Receptacle

E11A102A001US E11A102A011US

1.5

E11A152A001US E11A152A011US

NEMA 5-15P

NEMA 5-15R x6

2

E11A202A001US E11A202A011US

NEMA 5-20P

NEMA 5-20R x4

3

E11A302A001US E11A302A011US

NEMA L5-30R x1

208V model

1

E11A102A002US E11A102A012US

IEC60320-C13 x4

2

E11A202A002US E11A202A012US

3

E11A302A002US E11A302A012US

IEC60320-C20 Qty(1)IEC60320-C20 IEC60320-C19 x3 to NEMA L6-20P line cord option included.

*EPO=Emergency Power Off

External dimensions

W

PaintColor: Black (Munsell N1.5)

Output power (kVA) 1kVA 1.5kVA

Dimensions Width (W) Depth (D) 408mm (16.06in) 500mm (19.69in) 440mm (17.32in) 565mm (22.24in) 660mm (25.98in) 750mm (29.53in) 86mm (3.39in) Height (H)

Mass (Weight)

17kg (37.5lbs) 22kg (48.5lbs) 29kg (63.9lbs) 37kg (81.6lbs) 39kg (86.0lbs)

D

2kVA 3kVA (120V) 3kVA (208V)

6

H

Specifications

Item

E11A

Economy mode Active filter mode Double conversion mode

1kVA (0.7kW) / 1.5kVA (1.05kW) / 2kVA (1.4kW) / 3kVA (2.1kW) Topology Cooling Hybrid Forced Air Single-phase / 2 wire 120V: 1kVA / 1.5kVA / 2kVA / 3kVA 208V: 1kVA / 2kVA / 3kVA ±8% 60Hz ±1, 3, 5% Max. 0.7 Single-phase / 2 wire 0.7 120V model 208V model Voltage regulation Frequency Frequency range On Normal Operation On Battery Operation Voltage distortion Linear load Non-linear load Transient voltage regulation Input Voltage step 100% step load 120V: 1kVA / 1.5kVA / 2kVA / 3kVA 208V: 1kVA / 2kVA / 3kVA ±8% Max. 60Hz ±1,3,5% Max. ±5% Max. Greater than 200% (30 second interval) Greater than 800% (2 cycle) ±5% Max. 105% (200ms) Bypass Non-Hit Change (Auto Return) ±1% Max. ±0.5% Max. 3% Max. 7% Max. ±5% Max. ±2% Max. 0.85 Min. ±8% Max. 0.95 Min. ±5% ­20%, +15%

Remarks

Output power System

AC Input

Number of phase / wire Nominal voltage 120V model 208V model Voltage range Frequency Frequency range Power factor

50/60Hz Auto-sensing User selectable <1% Input voltage distortion / lag

AC Output

Number of phase / wire Power factor Nominal voltage

lag

Same as input frequency User selectable

During rated operations During rated operations / 100% rectifier load Power failure: feedback or supply fluctuation 0%: at the time of 100% sudden fluctuation Rated load power factor / at rated input

Overcurrent capacity

Overcurrent protection Battery Type Backup time Acoustic noise Nominal heat dissipation

Fuse Protection (1kVA), Breaker Protection (1.5, 2, 3kVA) Maintenance Free Sealed Lead-Acid Battery (small) 5 minutes (3kVA 120Vmodel: 3.5 minutes) 1kVA/1.5kVA: 40dB Max., 2kVA/3kVA: 45dB Max. Double conversion mode 120V model 1kVA: 125W, 1.5kVA: 200W, 2kVA: 250W, 3kVA: 410W 208V model 1kVA: 125W, 2kVA: 270W, 3kVA: 450W

Ambient Temp. of 25°C, under rated load At 1m (40in) from the front of unit

Environment Operating temperature Relative humidity Standard of safety

0 to 40°C (32 to 104°F) 20 to 90% UL1778-Fourth Edition(File # E226092), CE , FCC Part15 Subpart B Class A Non-condensing

A momentary power interruption lasting less than 3 ms occurs when switching from Economy Mode or Active Filter Mode to battery power. The unit can also be fixed to the Double Conversion Mode for applications that require zero transfer time from utility power to battery power. Please contact your local sales representative for additional input and ouput voltage options.

Run-time chart

Item Maximum Output (VA) Maximum Output (W) VA 100 200 300 400 500 600 700 800 900 1000 1200 1400 1500 1600 1800 2000 2200 2400 2600 2800 3000 W 70 140 210 280 350 420 490 560 630 700 840 980 1050 1120 1260 1400 1540 1680 1820 1960 2100 87 48 30 20 15 12 9 7 6 5 134 71 48 34 24 20 17 14 12 10 7 6 5

E11A102A

1000 700

E11A152A

1500 1050

E11A202A

2000 1400 Run-time (min) 150 87 61 48 37 30 25 20 18 15 12 9 8 7 6 5

E11A302A

3000 2100

1 E11A302A

3000 2100

2

230 120 75 55 49 39 32 26 23 20 16 13 11 10 9 8 7 6 5 4 3.5

240 150 87 71 69 48 40 34 31 28 20 17 16 14 12 10 9 8 7 6 5

The above run-time value assumes a load power factor = 0.7. (lag) Figures should be used for reference only. Actual backup times depend on charging conditions, ambient temperature, years in use, etc.

7

Options

Item Rack support rail Remote switch Dry contact signal interface card

Model

RM030US RSW006RUS PRE11A02US

Used for mounting the UPS onto a 19 inch rack. Supports depth of 555mm-913mm. Used for remotely turning on or off outlets of the UPS. (Cable lenght approx. 10m) Transmits contact signals containing information on the operation status of the UPS. Use to interface with UPS surveilance systems or customer equipment.

External battery

Model

Dimensions Width

For 1kVA 120V or 208V model For 1.5kVA 120V For 2kVA 120V or 208V model For 3kVA 120V model only For 3kVA 208V model only 440mm (17.32in)

Mass Depth

408mm (16.06in) 508mm (20.00in) 500mm (19.69in) 600mm (23.62in) 565mm (22.24in) 630mm (24.80in) 660mm (25.98in) 750mm (29.53in)

Run-time (Min)

15 20 1unit 1unit 1unit 1unit 1unit 1unit 1unit 2unit 2unit 3unit 3unit 2unit 30 1unit 2unit 40 2unit 45 60 3unit 2unit 3unit 2unit 3unit 2unit

Height

BCE11A102A01US BCE11A102A02US BCE11A152A01US BCE11A152A02US BCE11A202A01US BCE11A202A02US BCE11A302A03US BCE11A302A01US

86mm (3.39in)

(Weight) 20kg (44.09lbs) 29kg (63.93lbs) 26kg (57.32lbs) 38kg (83.77lbs) 34kg (74.95lbs) 47kg (103.62lbs) 50kg (110.21lbs) 52kg (114.61lbs)

* The optional battery modules indicated by 01US or 03US at the end of the model number enable the internal battery to be replaced from the front with the rack attached. With optional battery modules indicated by 02US at the end of the model number, the internal batteries within the rack cannot be replaced with the rack attached. It is necessary to remove the optional battery module from the rack, and then replace the batteries.

External demensions

W

Support rail

External demensions

Effective Dimensions (when fully retracted) PaintColor: Black (Munsell N1.5)

B

A

B

C 913mm (35.94in)

D

A

Effective Dimensions (when fully extended)

C

H

Notes when investigating use of this product in your applications

Before starting installation, assembling and use, read the "Operation Manual" carefully and use the product correctly in your applications. When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. (a) Medical equipment and other equipment that are related directly to human life. (b) Train or elevator that can give injury to human body. (c) Socially and publicly important computer systems (d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions. For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. Never modify this product or give additional processing to this product. For the installation and maintenance work, please consult with our company or with specialized company. For any inquiry or consultation, please contact our sales representative.

The names of companies and/or their products specified in this catalogue are the trade names, and/or trademarks and/or registered trademarks of such respective companies.

A

co.jp

CATALOG No.819-4 '07.10.C

Information

SUNPUS_E11A.indd

8 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

373502


You might also be interested in

BETA