MA11-1010 DRS MARLO COIL

NAVY FAN COIL UNITS

UNIT SIZE HORIZ VERT H1 V1 H2 V2 H3 V3 H4 V4 H5 V5 H6 V6 H7 V7 H8 V8 COIL CFM 145 240 350 530 690 950 1100 1650 COOLING CAPACITY BTUH GPM 5,850 1.9 9,690 3.0 15,280 4.8 22,890 7.3 30,500 9.5 39,910 13.2 45,560 15.1 72,920 24.5 ELECTRIC HEATER kW LO MED HI 1.2 2.2 3.3 1.2 2.2 3.3 1.75 3.5 5.25 2.0 4.0 6.0 2.0 4.0 6.0 3.0 6.0 9.0 3.0 6.0 9.0 3.0 6.0 9.0 DIMENSIONS IN INCHES WIDTH DEPTH LENGTH 25.0 10.0 50.0 25.0 10.0 50.0 27.0 14.0 52.0 36.0 14.0 52.0 44.0 14.0 52.0 39.0 17.0 52.0 52.0 17.0 52.0 62.0 17.0 52.0 WATER CONN 0.500 0.500 0.500 0.500 0.500 1.000 1.000 1.000 UNIT WT 275 285 350 420 500 500 660 780

Navy Fan Coil Units consist of direct drive fans, two speed motors per Mil-M-17059, Navy Standard air filters per Mil-F-16552, electric heaters (optional) per Mil-H-22577, operational controls per Mil-C-2212, thermostat, thermal and acoustical insulation and a chilled water cooling coil for use in connection with a chilled water system for air conditioning spaces on Navy, Marine, and commercial vessels. Navy Fan Coil Units have the fan and motor assembly vibro-isolated inside the unit cabinet so the unit can be hard mounted to a foundation without the use of external vibration isolation mounts. Fan Coil Units can be supplied for overhead mounting ("H" Series) or for bulkhead mounting ("V" Series). Navy Fan Coil Unit sizes 1 & 2 are designed to operate with no external static pressure, sizes 3-5 for up to .25 inches of external static pressure and sizes 6-8 for up to 1.0 inches of external static pressure.

Navy Fan Coil Units can be supplied with either low voltage protection (LVP) or low voltage release (LVR) capability. Fan Coil Units can be supplied with chilled water connections on either the right hand (RH) or left hand (LH) side of the cabinet. Navy Fan Coil Units have undergone complete qualification testing including high impact shock per Mil-S-901, vibration ­Type I & II per Mil-Std-167 and complete capacity testing in the manufacturer's environmental test lab. Specify the following information when ordering. A) B) C) D) Fan Coil Unit Size Heater kW Rating (if required) RH or LH Chilled Water Connections LVP or LVR Capability

NAVY STANDARD & MARINE HEATING VENTILATING & AIR CONDITIONING EQUIPMENT

DRS MARLO COIL

6060 Highway PP, High Ridge, MO 63049 · 636-677-6600 · Fax: 636-677-1203 Web Site: www.marlocoil.com · E-mail: [email protected]

Information

Layout 1

1 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

1281613


You might also be interested in

BETA
30ra-5pd.fm
Microsoft Word - Catalog WMC-1_Corrected Copy.doc
Microsoft Word - 15684 Centrifugal Water Chillers.doc