Read FM100(A4).pmd text version

SOLTEQ®

Equipment for Engineering Education & Research

FLUID FRICTION MEASUREMENTS APPARATUS

MODEL: FM 100

HIS Fluid Friction Measurements Apparatus (Model: FM 100) has been designed for students to study on the fluid friction head losses of an incompressible fluid flow. The unit is self contained supplied with facilities for students to study the friction losses on smooth-bore pipes of various diameters and an artificially roughened pipe. In addition to the study of losses in straight pipes, a wide range of accessories are O O also provided including 90 bend, elbow and T, 45 elbow and Y, sudden contraction and enlargement, inline strainer, various valves and flowmeters.

T

DESCRIPTION The investigation on friction head losses in various straight pipes can be done over a range of Reynolds numbers from 103 to nearly 105, covering the laminar, transitional and turbulent flow re-gimes in smooth pipe. An artificially roughened pipe is supplied which, at the higher Reynolds number, shows a clear departure from the typical smooth bore pipe characteristics.

For each size of test pipe, a short sample is provided loose so that students will be able to measure the exact diameter and visualise the nature of the internal finish. The ratio of the pipe diameter to distance of the pressure tappings from the ends of each pipe has been selected to minimise end entry effects. Isolating valves are provided so that the pipe to be tested can be selected without disconnecting or draining the system. Tests on parallel pipe

Rev1.0 28/06/2011

SOLTEQ®

Equipment for Engineering Education & Research

- EI DIGITAL INSTRUMENTATION

EXPERIMENTAL CAPABILITIES Laminar to turbulent flow regimes in pipes Energy losses in pipe fittings and bends Flow measurement using venturi meter Flow measurement using orifice plate Use of pitot static tube Use of manometers SPECIFICATIONS i) Test Rig: High quality frame and backboard to support test circuits comes with the following facilities: a) Smooth-bore pipes of various diameters (6mm, 10mm, 17mm) b) An artificially roughened pipe (17mm) c) 90o bend d) 90 o elbow e) 90 o T f) 45 o elbow g) 45 o Y h) Sudden enlargement i) Sudden contraction j) Ball valve k) Gate valve l) Globe valve m) Inline strainer n) Venturi made of clear acrylic o) Orifice plate made of clear acrylic p) Pitot static tube section made of clear acrylic ii) Manometers: Water manometer : 2 tubes of 1 m length with 1 mm reading; hand pump iIi) 1 unit of sifferential pressure transmitter

i) 2 units of digital indicator ii) 1 unit of electronic flowmeter

-DAS SOLDAS DATA ACQUISITION SYSTEM i) ii) iii) iv)

A PC with latest Pentium Processor An electronic signal conditioning system Stand alone data acquisition modules Windows based software Data Logging Signal Analysis Process Control Real-Time Display Tabulated Results Graph of Experimental Results

- CAL SOLCAL COMPUTER AIDED LEARNING SOFTWARE i) ii) iii) iv) Interactive multimedia features Graphical simulation Experiment results samples Full experiment manuals

REQUIREMENTS

Hydraulic Bench (FM 110) MANUAL

The unit is supplied with Operating and Experiment Manuals in English giving full descriptions of the unit, summary of theory, experimental procedures and typical experimental results.

SOLTEQ

Rev1.0 28/06/2011

configuration can be done whereby rapid and accurate flow measurement is possible over the full working range of the apparatus.

OPTIONAL ITEMS

SOLTEQ®

Equipment for Engineering Education & Research

TYPICAL EXPERIMENT RESULT

FLUID FRICTION COEFFICIENT OF A ROUGHENED PIPE 0.16 0.14 0.12 0.1 0.08 0.06 0.04 0.02 0 0 5000 10000 15000 20000

Reynolds No.

25000

HEAD LOSS DUE TO PIPE FITTINGS Sudden Enlargement 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 0 0.01 0.02 0.03

Hv

0.04

SOLTEQ

30000 35000

H

Fluid Friction Coefficient

0.05

0.06

0.07

Rev1.0 28/06/2011

SOLTEQ®

Equipment for Engineering Education & Research

SOFTWARE & E - LEARNING Our range of teaching equipment can be complemented with our SOLDAS and SOLCAL software.

SOLDAS® - Supervisory Control & Data Acquisition - Data Logging - Signal Analysis - Process Control - Real-Time Display - Tabulated Results - Graph of Experimental Results

SOLCAL® - Computer Aided Learning - Multimedia Features - Interactive - Graphic Simulation - Experiment Result Samples - Full Experiment Manuals

Contact us for a catalog CD SOLUTION ENGINEERING SDN. BHD.

(Co. No. 174876-M) Sales Office : No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara, 47100 Puchong, Selangor Darul Ehsan, Malaysia. Tel. No. : +(603) 80758000 Fax. No. : +(603) 80755784 R&D Office : G-2A, Incubator 3, Technology Park Malaysia, Bukit Jalil, 57000 Kuala Lumpur, Malaysia. Tel. No. : +(603) 8996 0023 Email : [email protected] Web site : http//www.solution.com.my/ MSC- Status

BUATAN MALAYSIA

AGENT:

Company

Rev1.0 28/06/2011

Information

FM100(A4).pmd

4 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

426535


You might also be interested in

BETA
Tribilogical behaviour of PTFE + Glass Fibber Composites Used for axial bearing and Under Water Lubrication
SURVEYING TILTING PAD JOURNAL BEARING AND GAS LABYRINTH SEAL COEFFICIENTS AND THEIR EFFECT ON ROTOR STABILITY