ENVIRONMENTAL HEALTH & SAFETY

Biohazardous and Medical Waste Disposal Guidelines

PROPER DISPOSAL METHOD

Sharps Container Biohazard waste All: Blades (scalpels, razors) Pasteur pipets Hypodermic needles with attached: H ·Syringes (barrels and plungers) ·Tubing Never remove needles from syringes!

ITEMS REQUIRING DISPOSAL

SHARPS

CULTURES AND DISPOSABLES

Contaminated: Petri dishes Disposable culture & tissue flasks M (p Materials (paper towels, kim wipes, etc.)

Red bag in hard-sided leak proof container with biohazard symbols on all sides and top Dispose liquid into sewer using running water

Biohazard waste

Contaminated liquid waste in container See below for disposing of blood and body fluids. If culture is NOT Biohazardous (BSL-1)

Container with liquid removed Decontaminate liquid

Regular trash Red bag in hard-sided leak proof container with biohazard symbols on all sides and top Regular trash

PIPETS

Contaminated Pipete Tips Disposable Pipets

Biohazard waste

Non-contaminated Pipete Tips Disposable Pipets Contaminated Broken and unbroken glass Sharps container

GLASS

Biohazard waste

Non-contaminated Broken and unbroken glass All: human blood animal blood blood elements body fluids liquid & semi-liquid materials All: Contaminated Animal carcasses & body parts Uncontaminated Animal carcasses & body parts Radioactive Animal carcasses & body parts All: Biohazardous material with chemical contamination Biohazardous material with radioactive contamination

Broken glass container Dilute with bleach 1:10 (final concentration = 0.5% sodium hypochlorite) or Autoclave (do not add bleach if autoclaving) Red bag in hard-sided leak proof container with biohaz symbol Black bag

Label bag exterior with approved radiation sticker

Recycling

CHEM ANIMAL BLOOD & AND BODIES BODY FLUIDS RAD

Dispose into sewer using running water Research Animal Facility (RAF) refrigerators (RAF) refrigerators (RAF) radioactive freezer

Version 2.2009

Call EH&S Chem Waste 5.7520 Call EH&S Radiation Waste 3.3765

Do not use needle clippers or cardboard pipet envelopes for sharps disposal.

For biohazardous waste, do not use orange or clear autoclave bags.

(C) 2009 Stanford University

For additional information contact Biosafety Office 725.1473