HYDRAUNYCOIL FH 4551

ISO 12922 ­ Category HFDU

FIRE RESISTANT HYDRAULIC FLUID ISO VG 68

HYDRAUNYCOIL FH 4551 is a fire resistant fluid based on a carboxylic ester. Its temperature operating range is comprised between -20 °C to +120 °C. It contains specific corrosion inhibitor to prevent corrosion of steel, copper, aluminium and other metals. HYDRAUNYCOIL FH 4551 is also readily biodegradable.

DESCRIPTION :

APPLICATION :

HYDRAUNYCOIL FH 4551 is intended for hydraulic equipments when the risk of fire is a concern. HYDRAUNYCOIL FH 4551 is widely used in high pressure equipments in steel and aluminium industry in which it has proven very efficient. The high level of biodegradability of HYDRAUNYCOIL FH 4551 is an additional benefit highly appreciated in tunnelling industry. HYDRAUNYCOIL FH 4551 is compatible with most of usual elastomers (see table below) and paintings. In most cases, HYDRAUNYCOIL FH 4551 can be used directly in existing systems - designed for mineral-oil based hydraulic fluids ­ without any modification. System conversion can be achieved by a straightforward drain-refill procedure. However, to keep the full benefit of fire resistance properties, ensure that the equipment is completely drained prior to fill it with HYDRAUNYCOIL FH 4551. Very good anti-wear and anti-corrosion performances High flash and auto-ignition points Good filterability Non-toxic High level of biodegradability

ADVANTAGES :

CHARACTERISTIC

- Appearance Density at 20°C Flash point, COC Fire Point A.I.T. Pour point Kinematic viscosity at 100°C 40°C -20°C Viscosity Index Acid number (pH=11) Foaming at 24°C 94°C 24/94°C Air release Filterability

UNIT

kg/dm °C °C °C °C

3

RESULT

Clear, bright and free from sediments and other impurities. 0.923 312 330 >400 -30 13.6 71.4 2552 197 1.16 0/0 0/0 0/0 14 1.1

TEST METHOD

visual examination ISO 12185 ISO 2592 ISO 2592 ASTM E 659 ISO 3016 ISO 3104 ISO 2909 ISO 6619 ISO 6247 ASTM D 3427 NFE 48-690

mm²/s mg KOH/g ml/ml ml/ml ml/ml min -

-

-

TFH4920-1E1a

September 2004 ­E1

CHARACTERISTIC

- Rusting test (sea water) - Copper corrosion - Vickers V104 C pump test Total wear - FZG - 4-ball test results 1hour ­ 392 N - Specific heat at 25°C - Coefficient of thermal expansion - Biodegradability

UNIT

mg damage stage mm kCal/kg/°C °C

-1

RESULT

Pass 1a 14 12 0.41 0.5 6.10

-4

TEST METHOD

ISO 7120/B ISO 2160 DIN 51389 DIN 51354 ASTM D 4172 ASTM D 2766 ISO 9439 CEC L33 A93

% %

> 60 90

ELASTOMER COMPATIBILITY DESCRIPTION

Butadiene Acrylonitrile (nitrile < 30%) Butadiene Acrylonitrile (nitrile > 30%) Polychloroprene ( temperature < 100°C) Viton Ethylene Propylene Rubber Polyurethane Teflon ® Natural Rubber

ISO Class.

NBR NBR CR FPM EPDM AU PTFE IR

Compatibility

N Y Y Y N Y Y N

TFH4551-2E1a

Marc 2006-E1

TFH4920-1E1a

September 2004 ­E1

TFH4920-1E1a

September 2004 ­E1

Information

NYCOLUBE 3060

3 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

647884


Notice: fwrite(): send of 204 bytes failed with errno=104 Connection reset by peer in /home/readbag.com/web/sphinxapi.php on line 531