Read GRF3122.indd text version

SURFACE MOUNT HIGH REPEATABILITY 8 GHz TO-5 Relays SIGNAL INTEGRITY TO 12 Gbps DPDT

SERIES DESIGNATION GRF312 RELAY TYPE Repeatable, RF TO-5 relay PERFORMANCE FEATURES

SERIES

GRF312

INTERNAL CONSTRUCTION

UPPER STATIONARY CONTACT

UNIFRAME

The ultraminiature GRF312 relay is designed to improve upon the GRF300/GRF303 relay's high frequency performance. The GRF312 offers monotonic insertion loss to 8 GHz. This improvement in RF insertion loss over the frequency range makes these relays highly suitable for use in attenuator and other RF circuits. The GRF312 features: · High repeatability. · Broader bandwidth. · Metal enclosure for EMI shielding.

MOVING CONTACT LOWER STATIONARY CONTACT

ARMATURE

GROUND SHIELD

· High isolation between control and signal paths. · Highly resistant to ESD. CONSTRUCTION FEATURES

ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS Temperature (Ambient) Vibration (General Note 1) Shock (General Note 1) Enclosure Weight Storage Operating ­65°C to +125°C ­55°C to +85°C 10 g's to 500 Hz 30 g's, 6ms half sine Hermetically sealed 0.09 oz. (2.55g) max.

The following unique construction features and manufacturing techniques provide excellent resistance to environmental extremes and overall high reliability. · Uni-frame motor design provides high magnetic efficiency and mechanical rigidity. · Minimum mass components and welded construction provide maximum resistance to shock and vibration. · Advanced cleaning techniques provide maximum assurance of internal cleanliness. · Gold-plated precious metal alloy contacts ensure reliable switching. · Hermetically sealed. · Solderable leads.

© 2008 TELEDYNE RELAYS

(800) 284-7007 · www.teledynerelays.com

GRF312 Page 1

GRF312\102008\Q4

SERIES GRF312 TYPICAL RF CHARACTERISTICS (See RF Notes)

GRF312 Isolation Across Contacts (RF Note 4 & 6)

0

GRF312 Insertion Loss (RF Note 4 & 6)

0

-0.5

Normally Open Normally Closed

-10

-1 -1.5

Insertion Loss (dB)

-20

Isolation (dB)

-2 -2.5 -3

Normally Closed

-30

-40

-3.5

Normally Open

-50

-4 -4.5

-60 0 1000 2000 3000 4000 5000 6000 7000 8000 Frequency (MHz)

-5 0 1000 2000 3000 4000 5000 Frequency (MHz) 6000 7000 8000

GRF312 VSWR (RF Note 4 & 6) 5 4.5 4 3.5

VSWR

Normally Open Normally Closed

GRF312 Pole-Pole Isolation (RF Note 5) 0 -10 -20

Pole-Pole Isolation (dB)

Energized De-Energized

-30 -40 -50 -60 -70 -80

3 2.5 2 1.5 1 0 1000 2000 3000 4000 5000 6000 7000 8000 Frequency (MHz)

-90 -100 0 1000 2000 3000 4000 Frequency (MHz) 5000 6000 7000 8000

GRF312 Time Response (RF Note 6)

1.1 0.9 90% 0.7

37ps reference

Volt

0.5 0.3 0.1 -0.1 -100

62.3ps propagation delay time 51.3ps pulse rise time

10%

0

100

200

300

400

500

600

700

800

900

Time (ps)

RF NOTES

1. Test conditions: a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a registered trademark of Rogers Corporation.) b. RF ground shield is soldered to PCB RF ground plane. c. Room ambient temperature. d. Terminals not tested were terminated with 50-ohm load. e. Contact signal level: ­10 dBm. f. No. of test samples: 2. Data presented herein represents typical characteristics and is not intended for use as specification limits. Data is per pole, except fpr pole-to-pole data. Data is the average from readings taken on all open contacts. Data is the average from readings taken between poles with coil energized and de-energized. Data is the average from readings taken on all closed contacts. Test fixture effect de-embedded from frequency and time response data.

2. 3. 4. 5. 6. 7.

GRF312 Page 2

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE

© 2008 TELEDYNE RELAYS

GRF312\102008\Q4

SERIES GRF312 GENERAL ELECTRICAL SPECIFICATIONS (@25°C unless otherwise noted) (Notes 2 & 3) Contact Arrangement Rated Duty Contact Resistance Contact Load Rating Contact Life Ratings Coil Operating Power Operate Time Release Time Intercontact Capacitance Insulation Resistance Dielectric Strength 2 Form C (DPDT) Continuous 0.15 max. initial (measured 1/8" from the header) Resistive: 1Amp/28Vdc Low level: 10 to 50 A @ 10 to 50 mV 10,000,000 cycles (typical) at low level 450 mW typical @ nominal rated voltage 4.0 mS max. 3.0 mS max. 0.4 pf typical 1,000 M min. between mutually isolated terminals 350 Vrms (60 Hz) @ atmospheric pressure

DETAILED ELECTRICAL SPECIFICATIONS (@25°C) BASE PART NUMBERS Coil Voltage, Nominal (Vdc) Coil Resistance (Ohms ±20%) Pick-up Voltage (Vdc max.)

GRF312-5 GRF312-12 GRF312-18 GRF312-26

5.0 50 3.6

12.0 390 9.0

18.0 880 12.3

26.5 1560 16.5

OUTLINE DIMENSIONS

.365 [9.27] MAX

Ø.370 [9.4] MAX

RF GROUND SHIELD

.031 [0.79] REF

.035 [0.89] REF

9 8 7

1 2 3

Ø.200 [Ø5.08] 36°±3° TYP

6

4

SCHEMATIC - TERMINAL VIEW

PIN NUMBERS ARE FOR REFERENCE ONLY; NOT MARKED ON RELAY

NOTES

1. Dimensions are in inches. Metric equivalents shown in parentheses. 2. Header dimensions, terminal numbering and schematic are as viewed from the terminals. 3. Positions 5 and 10 are for uninsulated case ground options. 4. To order the case ground option, after the series designator, add "Y" to the part number for position 5 or "Z" to the part number for position 10. Example: GRF312Y-5

GENERAL NOTES

1. 2.. 3. 4. Relays will exhibit no contact chatter in excess of 10 sec or transfer in excess of 1 sec. Relays may be subjected to 260 °C peak solder reflow temperature, 1 minute, 3 passes. Butt-lead ends are coplanar within .003" (0.08mm). Application notes available for PCB mounting information.

(800) 284-7007 · www.teledynerelays.com GRF312 Page 3

GRF312\102008\Q4

© 2008 TELEDYNE RELAYS

SERIES GRF312 TYPICAL SIGNAL INTEGRITY CHARACTERISTICS Normally Closed (Typ.)

+130 mV

0V

-130 mV

0 ps

40 ps

80 ps

120 ps

160 ps

Eye Height 266.5 mV

Eye Width 91.09 ps

SNR 20.75

JitterP-P 6.22 ps

Normally Open (Typ.)

+130 mV

0V

-130 mV

0 ps

40 ps

80 ps

120 ps

160 ps

Eye Height 239.6 mV

Eye Width 92.77 ps

SNR 14.52

JitterP-P 5.78 ps

PATTERN GENERATOR SETTINGS

· · · · · 10 Gbps Random Pulse Pattern Generator 231 - 1 PRBS signal PRBS output of 300 mVP-P (nominal) RF PCB effect (negligible) not removed from measurement Data shown is typical of both poles

GRF312 Page 4

GRF312\102008

© 2008 TELEDYNE RELAYS

(800) 284-7007 · www.teledynerelays.com