Read SU_SS_full.pdf text version

SECONDARY UNDERGROUND

CRS / P Submersible Splice Cover Elastimold® Cover & Plug Design Feature Adaptable Cable Sealing Sleeves allows a

wide conductor range coverage ­ just trim the sealing ring provided at the proper step

TYPE CRS / P

Rubber Splice Covers are used with

Aluminum and Copper Compression or SetScrew Connectors

Rubber Splice Covers are Easy to Install

· Eliminate taping · Increase system reliability · Minimize materials and labor costs

Rubber Splice Covers Provide Excellent:

· UV characteristics for overhead applications · Aging characteristics under continuous high operating temperatures (130°C) · Dielectric strength rating (>700 Volts/mil) · Resistance to Ozone, Acids, Alkalis

Rocket Cover Plug

Make Your Own Kit

1. Select the proper connector based on the conductor size(s) to be used ­ equal size both sides, or a reducer. (See pages 34 & 35). 2. Select the proper cover based on connector OD and length. Allow adequate space for connector expansion due to crimping. Kits are bagged and include installation instructions and silicone grease

Splice Covers / Kits

Wide Array of Aluminum and Copper Connectors Available Qualifications

· ANSI C119.1

Unlimited Applications

· Taps (Compression, bolted) · Terminations · Splices (Compression, Set-Screw) · Insulated pin terminals · Cable caps

CRS/P SUBMERSIBLE SPLICE COVER

Catalog No. CRSP350 CRSP350L CRSP500 CRSP500L Cable Range #6 to 350 MCM #6 to 350 MCM #6 to 500 MCM #6 to 500 MCM ID 1.06 1.06 1.31 1.31 Max. Connector Length* 4-7/8" 7-5/8" 4-7/8" 7-5/8"

Plugs supplied with PVC Support Tube

* Includes connector expansion due to crimps. · Plugs and covers may be ordered separately. Example: P350 (w/PVC Support Tube), CRS350L. · For other product options, consult the factory.

PG-SU-0706

Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility

1

SECONDARY UNDERGROUND

ESSK Submersible Splice Kits Kit Includes all Necessary Components

pre-assembled in a plastic bag for convenience (covers, plugs, connector(s), other hardware, silicone grease, installation instructions)

TYPE ESSK

Elastimold® Cover & Plug Design Feature Adaptable Cable Sealing Sleeves allows a

wide conductor range coverage ­ just trim the sealing ring provided at the proper step

Factory Pre-Cut Covers are Available

for installer convenience and to minimize installation errors

Rubber Splice Covers Provide Excellent:

· UV characteristics for overhead applications · Aging characteristics under continuous high operating temperatures (130°C) · Dielectric strength rating (>700 Volts/mil) · Resistance to Ozone, Acids, Alkalis

Elastimold® Kits Are Easy to Install

· No mismatched parts · All components are conveniently located · Increase system reliability

Splice Covers / Kits

ESSK SUBMERSIBLE SPLICE KITS

Splice Kit Catalog No. ESSK6 ESSK4 ESSK24 ESSK12 ESSK10 ESSK102 ESSKL6 ESSKL4 ESSKL2 ESSKL24 ESSKL10 ESSKL20 ESSKL2012 ESSKL2010 ESSK30 ESSK3010 ESSK3020 ESSK40 ESSK4010 ESSK4020 ESSK4030 ESSK350-T ESSK250 ESSK300 ESSK350 ESSK500 Conductor Size Side A Side B 6 4 2 1,2 1/0 1/0 6 4 2 2 1/0 2/0 2/0 2/0 3/0 3/0 3/0 4/0 4/0 4/0 4/0 350 250 300 350 500 6 4 4 1,2 1/0 2 6 4 2 4 1/0 2/0 1,2 1/0 3/0 1/0 2/0 4/0 1/0 2/0 3/0 350 250 300 350 500 Compr. Conn. Catalog No. CS64 CS68 CS72 CS73 CS78 CS77 KL20-1 KL22-1 KL25-1 KL24-1 KL36-1 KL47-1 KL45-1 KL46-1 KL58-1 KL56-1 KL57-1 KL69-1 KL66-1 KL67-1 KL68-1 KL350-T ASU250 ASU300 ASU350 ASU500 Rubber Cover Catalog No. Crimp Die

· Minimize material inventory and labor costs · All connectors have Contax® oxide inhibitor · Kits include silicone grease for ease of installation and convenience. · For other product options, consult the factory

5/8

CRSP350

.840

CRSP500

B80EA 1-1/8 321 CSA26

Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility

PG-SU-0706

SECONDARY UNDERGROUND

Breakaway Street Light Kits

Features / Benefits

· Completely waterproof · Individual fusing allows separation of kit without de-energizing complete circuit · Break-away style fuse holder eliminates risk of electrical shock. Exposed current carrying components are all contained in harmless load side of the kit · Readily identifiable problem area simplifies maintenance · Easy to install, no need for tapes or compounds · Insulated to 600 volts

Crimp-on Fuse** Sockets Line-Side Housing Receptacle

TYPE 65

Load-Side Housing Receptacle

Assembly Dowel

Applications

· Roadway lighting fixtures · Flood and area lighting fixtures · Power distribution systems

TYPE 65 BREAK-AWAY, SINGLE POLE IN-LINE

Catalog No. 65U 65LC Conductor Size AWG 14 ­ 6 4 or 2 Conductor Material* Copper Copper Packaging Unit Standard 1 20 1 20

®

All Kits Contain:

· Line and load-side housings · Metal fuse sockets · Assembly dowel · Lubricant · Wiper · Installation instructions

· Electrical rating: for 600 volt, 10-30 amp, 13/32" x 1-1/2" fuse. · Maximum overall length, installed, 7-3/4". diameter 1-1/8". * Available in aluminum. ** Fuse not included with kit. Do NOT use glass fuses.

Splice Covers / Kits

TYPE D65 BREAK-AWAY, DOUBLE POLE IN-LINE

Catalog No. D65U D65LC Conductor Size AWG 14 ­ 6 4 or 2 Conductor Material* Copper Copper Packaging Unit Standard 1 20 1 20

®

TYPE D65

Line-Side Housing Receptacle

· Electrical rating: for 600 volt, 10-30 amp, 13/32" x 1-1/2" fuse. · Maximum overall length installed, 7-3/4", diameter 2-5/16". * Available in aluminum. ** Fuse not included with kit. Do NOT use glass fuses.

Crimp-on Fuse** Sockets

All Kits Contain:

· Line and load-side housings · Metal fuse sockets · Assembly dowel · Lubricant · Wiper · Installation instructions

PG-SU-0706 Load-Side Housing Receptacle Assembly Dowel

Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility

SECONDARY UNDERGROUND

Submersible Street Light Connectors Street Light Connectors for pedestal, vault,

handhole, light pole base or direct burial

TYPE USL

100 Amps Connector current rating Identical in design to the street lighting connection provided on the field proven SQUID terminal buses; perfect in applications

calling for numerous street lighting taps

Conductor Use Range - #12 sol. (.080 min.)

through #4 str. (.312 max), aluminum or copper

Insulation Diameter Range from .22" to .42" 600 Volt Rated Contoured Plated Set-Screw does not damage

conductor when tightened down. Add suffix ­ H

USL11 USL30

Shipped with Type SL Covers with SLP push

out plugs

SL Cover is used as the "sealing sleeve" after a

conductor has been connected to a terminal

TYPE USL SQUID® SUBMERSIBLE STREET LIGHT CONNECTORS

Catalog No. USL11 USL30 USL11H USL30H No. of Ports 2 3 2 3 Width in. ­ 3.6 ­ 3.6 Height w/Sleeve in. 5.3 3.1 5.3 3.1 Screw Type Slotted Hex-Socket

To Seal Unused Terminals, install the sleeve

with plug

Splice Covers / Kits

Constructed of 56-T6 Aluminum Alloy Can

be used to connect small copper or aluminum conductors, #10 solid through #4 str. AWG, to any standard SQUID bus junction which accommodates type LAC lugs.

TYPE SLA1

TYPE SLA1 STREET LIGHT ADAPTER

Catalog No. SLA1 Description Street Light Adapter

4

Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility

PG-SU-0706

SECONDARY UNDERGROUND

WS, WL, WB, WH, SPL Sealing Sleeves

Squid® Sealing Sleeves

The key feature of the Blackburn SQUID System is its sealing method. There's no tape, no compound, no heat source required...just an EPDM rubber sealing sleeve that grips the conductor insulation on one end and seals onto the insulated bus on the other end. What makes it possible? EPDM rubber...the elastomer with a "memory." It always returns to its original shape. An underground system is only as good as its sealing-quality, and the SQUID design provides the best. To order, determine cable diameter over insulation O. D. Use approved grease to facilitate installation.

TYPE WS, WL, WB, WH

Sleeves Provided with Plug Installed for use

as terminal covers It is sometimes possible that #2 compact standard 600V Underground Service Entrance Cable may have an insulation O. D. less than 0.390"; in these instances it is suggested that a Type SC Adapter be used.

CRS/P SUBMERSIBLE SPLICE COVER

Sealing Range Catalog No. WS2P WL2P WL3P WB20P SC For Use On Single-Bolt UPC, SCU Two-Bolt UPC, UPB, SCU UPC, UPB, SCU UB Small Conductor Adapter for WS, WL2 and WB sleeves UBC Bus (large terminal)

(Conductor O.D. Over Insulation)

.4" ­ .9" .4" ­ .9" .5" ­ 1.2" .4" ­ .9"

Length in. 6-1/16" 8-5/16" 8-5/16" 5-3/8"

Qualifications

· RUS Listed

Splice Covers / Kits

.2" ­ .4"

­

WHB3P

.5" ­ 1.3"

7-3/8"

This EPDM Plug Can Be Used with SQUID® Type WL Sleeves to make splice cover for #6

stranded through #4/0 connections

TYPE SPL

TYPE WS, WL, WB AND WH WIDE RANGE SEALING SLEEVES

Catalog No. SPL6 Conductor O.D. Over Insulation .6 ­ .7

PG-SU-0706

Thomas & Betts Corporation 8155 T&B Boulevard Memphis TN 38125 800.888.0211 www.tnb.com/utility

5

Information

5 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

105290