4TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A

Mar. 03, 2006

© 2006 American Standard inc. All Rights Reserved

Pub. No. 22-1782-01

It's Hard to Stop a Trane.

Single Package Cooling System

Trane offers a complete family of cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs.

Introducing the new TRANE Single Package Cooling System.

Single Package Cooling Systems are easy and versatile to install. Because cooling and air handlingfunctions are all contained in a single cabinet, a Trane package air conditioner is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control and air distribution ducts, you have a highly efficient, total home comfort system. Single Package Cooling Systems provide better performance. Our single package air conditioners offer cooling efficiencies that are unmatched in the industry and provide you with a product far superior in performance than the competition.

2

Contents

Optional Equipment Listing General Data Heater Data SPEK Data Performance Cooling Data Typical Wiring Optional Equipment Dimensional Data Mechanical Specifications 4 5 8 9 10 13 16 21 25

3

Optional Equipment Listing

OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [] indicates accessories included)

Roof Curb Full Perimeter (4TCC3018-36A) 3 ................................................................... BAYCURB050A[ Roof Curb Full Perimeter (4TCC3042-60A) 3 ................................................................... BAYCURB051A[ Roof Curb Utility Extension Kit (BAYCURB050A) ................................................................. BAYUTIL101A[ Roof Curb Utility Extension Kit (BAYCURB051A) ................................................................. BAYUTIL102A[ 0-25% Manual Fresh Air Damper (4TCC3018-36A) 1. ...................................................... BAYOSAH001A[ 0-25% Manual Fresh Air Damper (4TCC3042-60A) 1. ...................................................... BAYOSAH002A[ Motorized Fresh Air Damper (4TCC3018-36A) 1. ............................................................ BAYDMPR101A[ Motorized Fresh Air Damper (4TCC3042-60A) 1. ............................................................. BAYDMPR102A[ 16" Round Duct Adapter (2 per box) (4TCC3018-36A) 6 ................................................. BAYSQRD001A[ 18" Round Duct Adapter (2 per box) (4TCC3018-60A) 6 ................................................. BAYSQRD002A[ 0-100% Mod Economizer w/Baro. Relief (4TCC3018-36A) 124 .................................... BAYECON101B[ 0-100% Mod. Economizer w/Baro. Relief (4TCC042-60A) 124. .................................... BAYECON102B[ 0-100% Horizontal Economizer (4TCC3018-36A) 12 . .................................................... BAYECON200A[ 0-100% Horizontal Economizer (4TCC3042-60A) 12 . .................................................... BAYECON201A[ Enthalpy Control for Economizer (solid state). .................................................................... BAYENTH001A[ Remote Potentiometer (All-BAYECON***A) ............................................................................ BAYSTAT023[ 1"-2" Filter Frame (4TCC3018-36A) (20 x 20 filter not included) 1. .................................... BAYFLTR101A[ 1"-2" Filter Frame (4TCC3042-60A) (20 x 20,20X18 filter not included) 1. ........................ BAYFLTR201A[ Evaporator Defrost Control (Low Ambient Cooling) Kit 5. ................................................. BAYLOAM011A[ Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ......................................... BAYLOAM105A[ Quick Start Kit (4TCC3-A1) .................................................................................................. BAYKSKT301A[ Crankcase Heater Recip (4TCC3018A1)(230v) 5. ............................................................. BAYCCHT003A[ Crankcase Heater Scroll(4TCC3036,48,60A1/3)(230v) 5. ................................................. BAYCCHT202A[ Crankcase Heater (4TCC3036,48,60A4)(460v) 5. ............................................................. BAYCCHT203A[ Adapter Curb 4TCC3018-036A to BAYCURB030,38 ........................................................ BAYADAP050A[ Adapter Curb 4TCC3018-036A to BAYCURB033 ............................................................. BAYADAP051A[ Adapter Curb 4TCC3042-060A to BAYCURB030,38 ........................................................ BAYADAP052A[ Adapter Curb 4TCC3042-060A to BAYCURB033 ............................................................. BAYADAP053A[ Adapter Curb 4TCC3042-060A to BAYCURB034 ............................................................. BAYADAP054A[ 12" Duct Shroud Covers Horizontal 4TCC3018-060A7. ................................................... BAYCOVR112A[ 18" Duct Shroud Covers Horizontal 4TCC3018-060A 7. .................................................. BAYCOVR118A[ Extreme Condition Mounting Kit - All BAYCURB & BAYADAP ......................................... BAYEXMK001A[ Extreme Condition Mounting Kit - All BAYUTIL .................................................................. BAYEXMK002A[ Extreme Condition Mounting Kit - All Slab Mounts ............................................................. BAYEXMK003A[ Lifting Lug Kit .......................................................................................................................... BAYLlFT002B[ SUPPLEMENTARY HEATERS (1 PHASE) 3.76/5.0 KW Heater (208/240V 1PH) (4TCC3018-060A1) ................................................. BAYHTRV105A[ 7.50/10.0 KW Heater (208/240V 1PH) (4TCC3024-060A1) ............................................... BAYHTRV110A[ 11.27/15.00 KW Heater (208/240V 1PH) (4TCC3030-060A1) ........................................... BAYHTRV115A[ 15.0/20.0 KW Heater (208/240V 1PH) (4TCC3048-060A1) ............................................... BAYHTRV120A[ SUPPLEMENTARY HEATERS (3 PHASE) 3.76/5.0 KW Heater (208/240V 3PH) (4TCC3018-060A3) ................................................. BAYHTRV305A[ 7.50/10.0 KW Heater (208/240V 3PH) (4TCC3024-060A3) ............................................... BAYHTRV310A[ 11.27/15.00 KW Heater (208/240V 3PH) (4TCC3030-060A3) ........................................... BAYHTRV315A[ 15.00/20.0 KW Heater (208/240V 3PH) (4TCC3048-060A3) ............................................. BAYHTRV320A[ 3.76/5.0 KW Heater (460V 3PH) (4TCC3018-060A4) ........................................................ BAYHTRV405A[ 7.50/10.0 KW Heater (460V 3PH) (4TCC3024-060A4) ...................................................... BAYHTRV410A[ 11.27/15.00 KW Heater (460V 3PH) (4TCC3030-060A4) .................................................. BAYHTRV415A[ 15.00/20.0 KW Heater (460V 3PH) (4TCC3048-060A4) .................................................... BAYHTRV420A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK060A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK061A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK062A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK063A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK064A[ Single Power Entry Kit 8 . ................................................................................................... BAYSPEK065A[ NOTES: 1 2 3 4 5 6 7 8 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ]

Must use internal filter frame when economizer or fresh air kit is used. Dry bulb control standard with economizer. Ships knocked down. Downflow only. Low Ambient cooling requires crankcase heater (BAYCCHT----A). It is the responsibility of the installing dealer to properly size the ductwork for each specific application. BAYCOVR112,118A will not cover BAYSQRD002A applications. See table on page 8 for matching kit with units and heaters.

4

General Data

4TCC3018A1000A 208-230/1/60 18000 RATINGS (COOLING) 1 Indoor Airflow (CFM) 675 Power Input (KW) 1.64 EER/SEER (BTU/Watt-Hr)6 11/13 Sound Rating No. 2 74 208-230/1/60 POWER CONN.--V/Ph/Hz Min. Brch. Cir. Ampacity 3 10.1 Fuse Size--Max. /Recmd.(Amps) 15/15 COMPRESSOR Volts/Ph/Hz 200-230/1/60 R.L. Amps--L.R. Amps 6.41/38.6 SPINE FIN OUTDOOR COIL--TYPE Rows/F.P.I. 2/24 Face Area (sq.ft.) 10.06 Tube Size (in.) 3/8 PLATE FIN INDOOR COIL--TYPE Rows/F.P.I. 3/15 Face Area (sq.ft.) 3.54 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT PROPELLER OUTDOOR FAN -- TYPE No. Used/Dia. (in.) 1/23 Type Drive/No. Speeds DIRECT/1 Motor--HP / R.P.M. 1/12/810 Volts/Ph/Hz 230/1/60 F.L. Amps--L.R. Amps 0.54/0.95 CENTRIFUGAL INDOOR FAN--TYPE Dia x Width (in.) 11 x 10 Drive / No. Speeds DIRECT/2 Motor--HP / R.P.M. 1/8/825 Volts/Ph/Hz 200-230/1/60 F.L. Amps--L.R. Amps 1/1.5 NO FILTER / FURNISHED? Type Recommended THROWAWAY Min. Face Area 7 (sq. ft.) 2.0 (R-410A) REFRIGERANT Charge (lbs.) 5.94 H X W X D DIMENSIONS Crated (in.) 45.86X44.5X52.03 WEIGHT 444/348 Shipping (lbs.) / Net (lbs.) MODEL RATED Volts/Ph/Hz 4TCC3024A1000A 208-230/1/60 23000 725 2.09 11/13 76 208-230/1/60 13.6 20/20 200-230/1/60 8.3/57.8 SPINE FIN 2/24 10.06 3/8 PLATE FIN 3/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/23 DIRECT/1 1/12/810 230/1/60 0.54/0.95 CENTRIFUGAL 11 x 10 DIRECT/2 1/4/825 200-230/1/60 1.4/2.8 NO THROWAWAY 2.67 (R-410A) 5.8 H X W X D 45.86X44.5X52.03 444/348 4TCC3030A1000A 208-230/1/60 28000 1000 2.67 11/13 75 208-230/1/60 21.7 35/35 208-230/1/60 14.7/72.5 SPINE-FIN 2/24 10.06 3/8 PLATE FIN 3/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/23 DIRECT/1 1/5/830 230/1/60 1.1/1.9 CENTRIFUGAL 11 x 10 DIRECT/3 1/2/1080 200-230/1/60 2/4.4 NO THROWAWAY 3.33 (R-410A) 6.3 H X W X D 45.86X44.5X52.03 445/349 4TCC3036A1000A 208-230/1/60 35000 1200 3.29 11/13 76 208-230/1/60 23.2 35/35 208-230/1/60 15.4/83 SPINE FIN 2/24 10.06 3/8 PLATE FIN 4/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/23 DIRECT/1 0.2/830 230/1/60 1.1/1.9 CENTRIFUGAL 11 x 10 DIRECT/3 1/2/1075 200-230/1/60 2.9/5.8 NO THROWAWAY 4.0 (R-410A) 7.7 H X W X D 5.86X44.5X52.03 460/364 4TCC3036A3000A 208-230/3/60 35000 1200 3.18 11/13 76 208-230/3/60 18.2 30/30 208-230/3/60 11.5/77 SPINE FIN 2/24 10.06 3/8 PLATE FIN 4/15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/23 DIRECT/1 1/5/830 230/1/60 1.1/1.9 CENTRIFUGAL 10 x 10 DIRECT/3 1/2/1075 200-230/1/60 2.9/5.8 NO THROWAWAY 4.0 (R-410A) 7.7 H X W X D 45.86X44.5X52.03 450/354

1Rated in accordance with

A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil.

2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG. 4 This value is approximate. For

more precise value, see Unit Nameplate.

6 Filters must be installed in

return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input,

unit is convertible to low input with a Low Fire accessory kit.

5 Based on U.S. Government

Standard Tests.

5

General Data

MODEL RATED Volts/Ph/Hz 4TCC3036A4000A 460/3/60 35000 RATINGS (COOLING) 1 Indoor Airflow (CFM) 1200 Power Input (KW) 3.29 EER/SEER (BTU/Watt-Hr)6 11/13 Sound Rating No. 2 76 460/3/60 POWER CONN.--V/Ph/Hz Min. Brch. Cir. Ampacity 3 8.7 Fuse Size--Max. /Recmd.(Amps) 15/15 COMPRESSOR Volts/Ph/Hz 460/3/60 R.L. Amps--L.R. Amps 5.13/35 SPINE FIN OUTDOOR COIL--TYPE Rows/F.P.I. 2/24 Face Area (sq.ft.) 10.06 Tube Size (in.) 3/8 PLATE FIN INDOOR COIL--TYPE Rows/F.P.I. 4/15 Face Area (sq.ft.) 3.54 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT PROPELLER OUTDOOR FAN -- TYPE No. Used/Dia. (in.) 1/23 Type Drive/No. Speeds DIRECT/1 Motor--HP / R.P.M. 1/5/830 Volts/Ph/Hz 230/1/60 F.L. Amps--L.R. Amps 0.6/1.3 CENTRIFUGAL INDOOR FAN--TYPE Dia x Width (in.) 10 x 10 Drive / No. Speeds DIRECT/2 Motor--HP / R.P.M. 1/2/ 1075 Volts/Ph/Hz 460/1/60 F.L. Amps--L.R. Amps 1.7/3.12 NO FILTER / FURNISHED? Type Recommended THROWAWAY Min. Face Area 7 (sq. ft.) 4.0 (R-410A) REFRIGERANT Charge (lbs.) 7.7 H X W X D DIMENSIONS Crated (in.) 45.86X44.5X52.03 WEIGHT Shipping (lbs.) / Net (lbs.) 450/354 4TCC3042A1000A 208-230/1/60 40000 1450 3.95 11/13 78 208-230/1/60 27.9 45/45 208-230/1/60 19.2/104 SPINE FIN 2/24 13.40 3/8 PLATE FIN 3/15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/27.6 DIRECT/1 1/4/825 230/1/60 1.4/3.5 CENTRIFUGAL 10 x 10 DIRECT/3 1/2/ 1075 200-230/1/60 2.5/3.2 NO THROWAWAY 4.67 (R-410A) 8.1 H X W X D 47.86X47.4X61.75 523/395 4TCC3048A1000A 208-230/1/60 46500 1600 4.23 11/13 80 208-230/1/60 31.1 50/50 208-230/1/60 20.5/109 SPINE FIN 2/24 13.4 3/8 PLATE FIN 3/15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/27.6 DIRECT/1 1/4/825 230/1/60 1.4/3.5 CENTRIFUGAL 10 x 10 DIRECT/3 3/4/ 1080 200-230/1/60 4/8.4 NO THROWAWAY 5.33 (R-410A) 8.2 H X W X D 47.86X47.4X61.75 607/479 4TCC3048A3000A 208-230/3/60 46500 1600 4.23 11/13 80 208-230/3/60 23.6 35/35 208-230/3/60 14.6/91 SPINE FIN 2/24 13.4 3/8 PLATE FIN 3/15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/27.6 DIRECT/1 1/4/825 230/1/60 1.4/3.5 CENTRIFUGAL 10 x 10 DIRECT/3 3/4/1080 200-230/1/60 4/8.4 NO THROWAWAY 5.33 (R-410A) 8.2 H X W X D 47.86X47.4X61.75 607/479 4TCC3048A4000A 460/3/60 46500 1600 4.23 11/13 80 460/3/60 11.7 15/15 460/3/60 7.05/46 SPINE FIN 2/24 13.4 3/8 PLATE FIN 3/15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1/27.6 DIRECT/1 1/4/825 460/1/60 0.74/1.6 CENTRIFUGAL 10 x 10 DIRECT/2 3/4/1080 460/1/60 2.2/4.36 NO THROWAWAY 5.33 (R-410) 8.2 H X W X D 47.86X47.4X61.75 607/479

1Rated in accordance with

A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil.

2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG. 4 This value is approximate. For

more precise value, see Unit Nameplate.

6 Filters must be installed in

return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input,

unit is convertible to low input with a Low Fire accessory kit.

5 Based on U.S. Government

Standard Tests.

6

General Data

4TCC3060A1000A 208-230/1/60 58000 RATINGS (COOLING) 1 Indoor Airflow (CFM) 1800 Power Input (KW) 5.27 EER/SEER (BTU/Watt-Hr)6 11/13 Sound Rating No. 2 79 208-230/1/60 POWER CONN.--V/Ph/Hz Min. Brch. Cir. Ampacity 3 43.5 Fuse Size--Max. /Recmd.(Amps) 60/60 COMPRESSOR Volts/Ph/Hz 208-230/1/60 R.L. Amps--L.R. Amps 27.6/158 SPINE FIN OUTDOOR COIL--TYPE Rows/F.P.I. 2/24 Face Area (sq.ft.) 13.84 Tube Size (in.) 3/8 PLATE FIN INDOOR COIL--TYPE Rows/F.P.I. 4/15 Face Area (sq.ft.) 5 Tube Size (in.) 3/8 Refrigerant Control EXPANSION VALVE Drain Conn. Size (in.) 3/4 FEMALE NPT PROPELLER OUTDOOR FAN -- TYPE No. Used/Dia. (in.) 1/27.6 Type Drive/No. Speeds DIRECT/1 Motor--HP / R.P.M. 1/4/825 Volts/Ph/Hz 230/1/60 F.L. Amps--L.R. Amps 1.4/3.5 CENTRIFUGAL INDOOR FAN--TYPE Dia x Width (in.) 11 x 10 Drive / No. Speeds DIRECT/3 Motor--HP / R.P.M. 1/1075 Volts/Ph/Hz 208-230/1/60 F.L. Amps--L.R. Amps 7.6/7.6 NO FILTER / FURNISHED? Type Recommended THROWAWAY Min. Face Area 7 (sq. ft.) 6.67 (R-410A) REFRIGERANT Charge (lbs.) 10 H X W X D DIMENSIONS Crated (in.) 49.86X47.4X61.75 WEIGHT Shipping (lbs.) / Net (lbs.) 610/482 MODEL RATED Volts/Ph/Hz 4TCC3060A3000A 208-230/3/60 58000 1800 5.27 11/ 13.0 79 208-230/3/60 31.7 50/50 208-230/3/60 18.1/137 SPINE FIN 2 / 24 13.84 3/8 PLATE FIN 4 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1 / 27.6 DIRECT / 1 1/4 / 825 230/1/60 1.4 /3.5 CENTRIFUGAL 11 X 10 DIRECT/3 1 / 1075 208-230/1/60 7.6/7.6 NO THROWAWAY 6.67 (R-410A) 10 H X W X D 49.86 X 47.4 X 61.75 610 / 482 4TCC3060A4000A 460/3/60 58000 1800 5.27 11 / 13.0 79 460/3/60 19.5 25/25 460/3/60 8.97/62 SPINE FIN 2 / 24 13.84 3/8 PLATE FIN 4/ 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 1 / 27.6 DIRECT / 1 1/4 / 825 460/1/60 0.74 /1.6 CENTRIFUGAL 11 X 10 DIRECT/3 1 / 1075 208-230/1/60 7.6/7.6 NO THROWAWAY 6.67 (R-410A) 10 H X W X D 49.86 X 47.4 X 61.75 610 / 482

1Rated in accordance with

A.R.I. Standard 210/240. Noise tested in accordance with A.R.I. Standard 270. A.R.I. standard rating conditions are: 80 D.B. 67 W.B. entering air to indoor coil. 95 D.B. entering air to outdoor coil.

2 All models are UL Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG. 4 This value is approximate. For

more precise value, see Unit Nameplate.

6 Filters must be installed in

return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input,

unit is convertible to low input with a Low Fire accessory kit.

5 Based on U.S. Government

Standard Tests.

7

Heater Data

4TCC3018A to 4TCC3060A Heater Data

UNIT MODEL ELECTRIC HEATER MODEL HEATER CAPACITY RATED PHASE AMPS VOLTAGE KW 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 480 480 480 480 480 480 480 1 1 1 1 1 1 1 1 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 18/21 18/21 36/42 18/21 36/42 54/63 18/21 36/42 54/63 72/83 10/12 21/24 31/36 10/12 21/24 31/36 42/48 6 12 18 6 12 18 24 3.76/5.0 3.76/5.0 7.50/10.0 3.76/5.0 7.50/10.0 11.27/15.0 3.76/5.0 7.50/10.0 11.27/15.0 15.00/20.0 3.76/5.0 7.50/10.0 11.27/15.0 3.76/5.0 7.50/10.0 11.27/15.0 15.00/20.0 5 10 15 5 10 15 20 BTUH 12800/17100 12800/17100 25600/34100 12800/17100 25600/34100 38500/51200 12800/17100 25600/34100 38500/51200 51200/68300 12800/17100 25600/34100 38500/51200 12800/17100 25600/34100 38500/51200 51200/68300 17100 34100 51200 17100 34100 51200 68300 1 1 1 1 1 2 1 1 2 2 1 1 2 1 1 2 2 1 1 2 1 1 2 2 NO. OF STAGES KW / STAGE MCA (2) 1 3.76/5.0 3.76/5.0 7.50/10.0 3.76/5.0 7.50/10.0 7.50/10.0 3.76/5.0 7.50/10.0 7.50/10.0 7.50/10.0 3.76/5.0 7.50/10.0 7.50/10.0 3.76/5.0 7.50/10.0 7.50/10.0 7.50/10.0 5 10 10 5 10 10 10 5 10 5 3.76/5.0 7.50/10.0 3.76/5.0 3.76/5.0 7.50/10.0 3.76/5.0 2 23/26 23/26 45/52 23/26 45/52 68/78 23/26 45/52 68/78 90/104 13/15 26/30 39/45 13/15 26/30 39/45 52/60 8 15 23 8 15 23 30 MAX. CANADA FUSE ONLY MAX. OR HQCR CKT BKR CKT BKR SIZE (5) SIZE (4) 25/30 25/30 45/60 25/30 45/60 70/80 25/30 45/60 70/80 90/110 15/15 30/30 40/45 15/15 30/30 40/45 60/60 15 15 25 15 15 25 30 25/30 25/30 45/60 25/30 45/60 70/80 25/30 45/60 70/80 90/110 15/15 30/30 40/45 15/15 30/30 40/45 60/60 15 15 25 15 15 25 30

^W/TC*3018A1 ^W/TC*3024A1 ^W/TC*3030A1 ^W/TC*3036A1 ^W/TC*3042A1

BAYHTRV105A BAYHTRV105A BAYHTRV110A BAYHTRV105A BAYHTRV110A BAYHTRV115A# BAYHTRV105A

^W/TC*3048A1 ^W/TC*3060A1

BAYHTRV110A BAYHTRV115A# BAYHTRV120A# BAYHTRV305A BAYHTRV310A BAYHTRV315A BAYHTRV305A

^W/TC*3036A3

^W/TC*3048A3 ^W/TC*3060A3

BAYHTRV310A BAYHTRV315A BAYHTRV320A BAYHTRV405A

^W/TC*3036A4

BAYHTRV410A BAYHTRV415A BAYHTRV405A

^W/TC*3048A4 ^W/TC*3060A4

BAYHTRV410A BAYHTRV415A BAYHTRV420A

NOTES: 1. Any power supply and circuits must be wired and protected in accordance with local electrical codes. (2) The MCA values listed are for electric heater only. 3. Field wire must be rated at least 75°C (4) The HACR circuit breaker is for U.S.A. installations only. (5) For Canada installation reference only. * Heater uses fuses.

8

Single Power Entry Kit Data

SPEK 4TCC3018A to 4TCC3060A

SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION

SINGLE POWER ENTRY KIT HEATER MODEL UNIT MODEL

4TC*3018A1 4TC*3024A1 4TC*3030A1 BAYHTRV105A 4TC*3036A1 4TC*3042A1 BAYSPEK060 4TC*3048A1 4TC*3024A1 4TC*3030A1 BAYHTRV110A 4TC*3036A1 4TC*3042A1 4TC*3048A1 4TC*3036A3 BAYHTRV305A 4TC*3048A3 4TC*3060A3 4TC*3036A3 BAYHTRV310A 4TC*3048A3 4TC*3060A3 4TC*3036A3 BAYHTRV315A 4TC*3048A3 4TC*3060A3 BAYSPEK061A BAYHTRV405A 4TC*3036A4 4TC*3048A4 4TC*3060A4 4TC*3036A4 BAYHTRV410A 4TC*3048A4 4TC*3060A4 4TC*3036A4 BAYHTRV415A 4TC*3048A4 4TC*3060A4 4TC*3048A4 BAYHTRV420A 4TC*3060A4 BAYHTRV105A BAYSPEK062A # BAYHTRV110A 4TC*3060A1 62 70 From Dwg. 21C932254 P01&2 # Single Circuit Power fuses are supplied if required for unit and/or heater. 4TC*3060A1 40 44 40 70 30 29 31 54 55 56 55 57 18 24 32 33 35 40 48 50 55 10 12 20 17 18 25 25 25 32 33 35 45 50 BAYHTRV120A 60 60 BAYSPEK064A # 60 60 60 30 35 45 35 35 45 50 50 60 15 15 25 20 20 25 25 25 35 35 BAYHTRV320A 4TC*3060A3 70 70 4TC*3060A1 4TC*3048A3 114 65 125 70 BAYSPEK063A # 4TC*3048A1 4TC*3060A1 4TC*3048A1 83 88 109 90 90 110

MIN CKT AMP

27 28 29

MAX OVERCURRENT DEVICE

30 30 35

SINGLE POWER ENTRY KIT

HEATER MODEL

UNIT MODEL

4TC*3030A1 4TC*3036A1

MIN CKT AMP

81 82 81

MAX OVERCURRENT DEVICE

90 90 90

BAYHTRV115A

4TC*3042A1

9

Performance Data Cooling

4TCC3018A AT 600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 17.5 18.2 19.7 21.2 15.9 16.6 17.8 19.3 14.3 14.9 16.0 17.3 12.6 13.2 14.2 15.3 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 11.6 14.0 16.3 17.5 10.7 12.8 14.9 16.3 9.2 11.1 12.9 14.1 7.6 9.2 10.7 11.7 11.0 10.1 8.7 7.2 10.3 9.4 8.2 6.8 9.5 8.7 7.5 6.2 13.2 12.1 10.5 8.7 12.4 11.4 9.8 8.1 11.4 10.5 9.0 7.5 15.4 14.2 12.2 10.1 14.3 13.2 11.4 9.5 12.6 12.2 10.5 8.7 15.9 15.5 13.3 11.1 14.3 14.5 12.5 10.4 12.6 13.2 11.5 9.5 COMPR. KW 1.43 1.44 1.46 1.47 1.57 1.58 1.60 1.62 1.71 1.72 1.75 1.76 1.85 1.86 1.89 1.91 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 525 675 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 18000 BTUH AIRFLOW = 675 CFM COMPRESSOR POWER = 1183 WATTS I.D. FAN POWER = 236 WATTS O.D. FAN POWER = 217 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

4TCC3024A AT 800 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 22.5 23.5 25.3 27.3 20.6 21.5 23.2 25.0 18.8 19.6 21.1 22.8 16.9 17.6 19.0 20.5 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 14.7 17.7 20.6 22.5 13.5 16.2 18.9 20.7 11.6 14.0 16.3 17.8 9.7 11.6 13.5 14.8 13.8 12.6 10.9 9.1 12.8 11.7 10.1 8.4 11.7 10.8 9.3 7.7 16.6 15.2 13.1 10.9 15.4 14.1 12.2 10.1 14.1 13.0 11.2 9.3 19.3 17.7 15.3 12.7 17.9 16.4 14.2 11.8 16.5 15.1 13.0 10.8 20.6 19.4 16.7 13.9 18.8 18.0 15.5 12.9 16.9 16.5 14.2 11.8 COMPR. KW 1.91 1.92 1.95 1.97 2.07 2.08 2.12 2.14 2.23 2.25 2.28 2.31 2.39 2.41 2.45 2.47 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 700 900 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 23000 BTUH AIRFLOW = 725 CFM COMPRESSOR POWER = 1698 WATTS I.D. FAN POWER = 191 WATTS O.D. FAN POWER = 202 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

4TCC3030A AT 1000 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 26.8 28.0 30.2 32.6 24.9 26.0 28.0 30.2 23.0 24.0 25.9 27.9 21.1 22.0 23.7 25.6 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 18.3 22.0 25.6 26.8 16.8 20.1 23.5 25.7 14.5 17.4 20.3 22.1 12.0 14.4 16.8 18.4 17.3 15.9 13.7 11.4 16.3 15.0 12.9 10.7 15.3 14.0 12.1 10.0 20.8 19.1 16.5 13.7 19.6 18.0 15.5 12.9 18.3 16.8 14.5 12.1 24.3 22.3 19.2 15.9 22.9 21.0 18.1 15.0 21.1 19.6 16.9 14.0 24.9 24.3 21.0 17.4 23.0 22.9 19.8 16.4 21.1 21.4 18.5 15.4 COMPR. KW 2.24 2.26 2.29 2.32 2.49 2.50 2.55 2.57 2.73 2.75 2.80 2.82 2.98 3.00 3.05 3.08 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 875 1125 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 28000 BTUH AIRFLOW = 1000 CFM COMPRESSOR POWER = 1922 WATTS I.D. FAN POWER = 315 WATTS O.D. FAN POWER = 308 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

10

Performance Data Cooling

4TCC3036A AT 1200 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 33.6 35.0 37.8 40.8 31.2 32.5 35.0 37.8 28.7 29.9 32.2 34.8 26.2 27.3 29.5 31.8 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 22.6 27.2 31.7 33.6 20.8 25.0 29.1 31.8 17.9 21.5 25.1 27.5 14.9 17.9 20.8 22.8 21.6 19.9 17.1 14.2 20.5 18.9 16.3 13.5 19.3 17.8 15.3 12.7 26.0 23.9 20.6 17.1 24.7 22.7 19.6 16.2 23.3 21.3 18.4 15.3 30.3 27.8 24.0 19.9 28.7 26.4 22.8 18.9 26.2 24.9 21.5 17.8 31.2 30.4 26.3 21.8 28.7 28.9 24.9 20.7 26.2 27.2 23.5 19.5 COMPR. KW 2.80 2.82 2.86 2.89 3.11 3.13 3.18 3.21 3.42 3.44 3.50 3.53 3.74 3.76 3.82 3.86 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 1050 1350 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 35000 BTUH AIRFLOW = 1200 CFM COMPRESSOR POWER = 2556 WATTS I.D. FAN POWER = 420 WATTS O.D. FAN POWER = 206 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

4TCC3042A AT 1400 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 38.1 39.8 42.9 46.3 35.5 37.0 39.9 43.1 32.9 34.3 36.9 39.9 30.2 31.5 33.9 36.6 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 25.6 30.7 35.8 38.1 23.5 28.2 32.9 35.9 20.2 24.3 28.4 31.0 16.8 20.2 23.5 25.7 24.6 22.5 19.4 16.1 23.4 21.5 18.6 15.4 22.2 20.4 17.6 14.6 29.5 27.1 23.4 19.4 28.2 25.8 22.3 18.5 26.7 24.5 21.1 17.5 34.4 31.6 27.2 22.6 32.8 30.1 26 21.6 30.2 28.5 24.6 20.4 35.5 34.5 29.8 24.7 32.9 32.9 28.4 23.6 30.2 31.2 26.9 22.3 COMPR. KW 3.17 3.19 3.24 3.27 3.53 3.55 3.61 3.65 3.89 3.92 3.98 4.02 4.26 4.28 4.35 4.40 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) LOW HIGH AIRFLOW 1225 1575 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 40000 BTUH AIRFLOW = 1450 CFM COMPRESSOR POWER = 3009 WATTS I.D. FAN POWER = 518 WATTS O.D. FAN POWER = 109 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

4TCC3048A AT 1600 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 43.8 45.6 49.2 53.1 41.4 43.2 46.5 50.2 39.0 40.7 43.8 47.3 36.6 38.2 41.2 44.5 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 29.8 35.8 41.7 43.8 27.3 32.9 38.3 41.9 23.6 28.3 33 36.1 19.6 23.5 27.4 30.0 28.8 26.4 22.8 18.9 27.7 25.4 21.9 18.2 26.5 24.3 21.0 17.4 34.6 31.7 27.4 22.7 33.3 30.5 26.3 21.9 31.9 29.2 25.2 20.9 40.3 37.0 31.9 26.5 38.8 35.6 30.7 25.5 36.6 34.1 29.4 24.4 41.4 40.4 34.9 28.9 39.0 38.9 33.6 27.8 36.6 37.3 32.1 26.7 COMPR. KW 3.74 3.76 3.82 3.86 4.13 4.16 4.23 4.27 4.53 4.55 4.63 4.67 4.92 4.95 5.03 5.08 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 1400 1800 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 46500 BTUH AIRFLOW = 1600 CFM COMPRESSOR POWER = 3330 WATTS I.D. FAN POWER = 583 WATTS O.D. FAN POWER = 314 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

11

Performance Data Cooling

4TCC3060A AT 2000 CFM (CAPACITIES ARE NET IN BTUH/1000-INDOOR FAN HEAT DEDUCTED)

O.D. D.B. 85 I.D. W.B. 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 TOTAL CAP. 56.0 58.4 62.9 67.9 52.1 54.3 58.5 63.2 48.2 50.2 54.1 58.4 44.3 46.2 49.7 53.7 SENS. CAP. AT ENTERING D.B. TEMP. 72 75 78 80 35.7 42.9 50.0 54.6 32.7 39.4 45.9 50.1 28.3 34.0 39.6 43.3 23.4 28.2 32.8 35.9 34.3 31.5 27.2 22.5 32.8 30.1 25.9 21.5 31.0 28.5 24.6 20.4 41.2 37.8 32.7 27.1 39.4 36.1 31.2 25.9 37.3 34.2 29.6 24.5 48.1 44.1 38.1 31.6 45.9 42.1 36.3 30.2 43.5 39.9 34.4 28.6 52.1 48.2 41.6 34.5 48.2 46.0 39.7 33.0 44.3 43.6 37.7 31.2 COMPR. KW 4.72 4.75 4.82 4.87 5.24 5.27 5.36 5.41 5.77 5.80 5.90 5.95 6.29 6.33 6.44 6.50 CORRECTION FACTORS FOR OTHER AIRFLOWS (MULTIPLY DATA BY FACTOR) AIRFLOW LOW HIGH 1750 2250 TOTAL CAPACITY 0.98 1.02 SENSIBLE CAPACITY 0.97 1.03

95

VALUES AT ARI RATING CONDITIONS TOTAL NET CAPACITY = 58000 BTUH AIRFLOW = 1800 CFM COMPRESSOR POWER = 4391 WATTS I.D. FAN POWER = 595 WATTS O.D. FAN POWER = 287 WATTS S.E.E.R. = 13.00 BTUH/WATT E.E.R = 11.00 BTUH/WATT ALL TEMPERATURES IN DEGREES F.

105

115

12

Typical Field Wiring

UNIT CONTROL BOX

UNIT HEATER AREA

POLARIZED PLUG ELECTRIC HEATER CONTROL BOX

B G Y W1 W2 O T R UNIT LOW VOLTAGE AREA

GROUND WIRE 1 PH 1 PH POWER POWER TYPICAL THERMOSTAT 3 PH 3 PH POWER POWER UNIT HEATER NOTE 1,8

COMMON FAN COMPRSSOR 1ST STAGE ELECTRIC HEAT 2ND STAGE ELECTRIC HEAT SWITCHOVER VALVE DEFROST CONTROL 'T' SIGNAL 24 VOLTS

FIG. 1

SINGLE POWER ENTRY ACCESSORY CONNECTIONS

UNIT CONTROL BOX UNIT HEATER AREA

FIG. 2

ECONOMIZER ACCESSORY CONNECTIONS

(NOT APPLICABLE TO THE WCM---F MODELS)

TO ECONOMIZER FACTORY PROVIDED FIELD INSTALLED WIRES NOTE 9 ELECTRIC HEATER CONTROL BOX

FACTORY PROVIDED FIELD CONNECTED WIRES TO COMPR. CONTACTOR

(BL) (YL) (GR) (PR)

(BL) B

(GR) G (YL)

UNIT FUSES

SPE ACCESSORY KIT

HEATER FUSES

Y

(WH) W1 (WH) W2 (OR) (OR) (BR) T UNIT LOW VOLTAGE AREA (RD) R (OR)

O

UNIT LOW VOLTAGE AREA GROUND WIRE 1 PH POWER 3 PH POWER

SEE SPEK INSTALLER'S GUIDE FOR ALL OTHER EXAMPLES

TYPICAL 2-STAGE THERMOSTAT

SINGLE POWR ENTRY

FIG. 3

OUTDOOR THERMOSTAT ACCESSORY CONNECTIONS

HEATER SECOND STAGE AMBIENT TEMPERATURE LOCKOUT NOTE 7,8

UNIT LOW VOLTAGE AREA

(WH) W1 (WH) W2

UNIT LOW VOLTAGE AREA

HEATER AMBIENT TEMPERATURE LOCKOUT NOTE 7,8 (WH) W1 (WH) W2

OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A NOTE 10 TYPICAL THERMOSTAT TYPICAL THERMOSTAT

OUTDOOR THERMOSTAT ACCESSORY BAYSTAT033A NOTE 10

13

Typical Wiring

14

Typical Wiring

From Dwg. 21D757165 P02

15

Optional Equipment

BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening)

HVAC Unit A Economizer rain hood Outside air dampers Return air dampers Mist eliminator Relief damper Roofcurb

Economizer

Required filter kit, order separately

Unit ApplicationM odels 2/4YC,WC3018-036A 4TC*3018-036A 2/4YC,WC3042-060A 4TC*3042-060A

A 20.125"

BAYECON101A

BAYECON102A

24.375"

Return Duct

BAYCON200,201A Horizontal Economizer and Rain Hood

Economizer

A

B C

Gaskets (2) Duct Rain Hood

Economizer BAYECON200AA

Unit Application Models 2/4YC,WC3018-036A 4TC*3018-036A 2/4YC,WC3042-060A 4TC*3042-060A

A 22.00"

B 20.00"

C 16.87"

BAYECON201AA

24.00"

22.65"

19.00"

16

Optional Equipment

BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel)

A

FULLY OPEN D C 2/3 1/3

B

FULLY CLOSED

Manual Fresh Air Model BAYOSAH001 BAYOSAH002

Unit Application Models 2/4YC,WC3018-036A 4TC*3018-036A 2/4YC,WC3042-060A 4TC*3042-060A

A 22 7/16" 25 3/16"

B 20 11/16" 20 11/16"

C 12 3/8" 12 3/8"

D 9 3/16" 9 3/16"

BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening)

A

C

B

E

D

Unit Application Models BAYDMPR101A BAYDMPR102A

A

B 11 13/16" 15 1/8"

C 10 1/4" 10 1/4"

D 11 1/2" 11 1/2"

E 12 1/4" 12 1/4"

2/4YC,WC3018-036A 15 13/16" 4TC3018-036A 2/4YC,WC3042-060A 4TC3042-060A 18 3/16"

17

Optional Equipment

BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR *****018-036A

38.86" 15" 1.50" SUPPLY 19.50" RETURN 1.50" 19.50" 1.50" 1.50" 38.86" 14" .812" 46.39"

1.50"

D A WOOD NAILER SUPPLY AIR RETURN AIR B CHANNEL SIDE CHANNEL END

C

HOLE IN ROOF

SERVICE CLEARANCE DIMENSIONS

A B C D

43.39" 22"

42"

36"

12"*

42"

*42" WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY

BAYCURB050A

18

Optional Equipment

BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A

41.861" 20" 1.50" SUPPLY 19.50" RETURN 1.50" 19.50" 1.50" 1.50" 38.86" 14" 56.111"

.812"

1.50"

D A WOOD NAILER SUPPLY AIR RETURN AIR C B CHANNEL SIDE CHANNEL END

HOLE IN ROOF

SERVICE CLEARANCE DIMENSIONS

A B C D

53.11" 22"

42"

36"

12"*

42"

*42" WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY

BAYCURB051A

19

Optional Equipment

BAYFLTR101, 201A, 1" - 2" Filter Rack (Mounts in Filter/Coil Section)

Filter

20

Dimensional Data and Weights

RETURN

SUPPLY

Figure 1. TCC3018A through TCC3036A (1 of 2)

21

Dimensional Data and Weights

SUPPLY

RETURN

36 [79] 36 [79] 36 [79] 903.29 [35-9/16] 36 [78] 36 [78] 36 [80] 37 [81] 38 [84]

57 [125] 57 [125] 57 [125] 56 [124] 56 [124] 58 [127] 58 [128] 61 [134]

40 [88] 40 [88] 40 [88] 41 [89] 41 [89] 42 [92] 41 [91] 43 [94]

25 [56] 25 [56] 25 [56] 26 [56] 26 [56] 26 [58] 26 [57] 27 [60]

158 [348] 158 [348] 158 [349] 161 [354] 158 [348] 162 [357] 162 [358] 169 [372]

635 [25.0] 635 [25.0] 635 [25.0] 635 [25.0] 635 [25.0] 635 [25.0] 635 [25.0] 635 [25.0]

508 [20.0] 508 [20.0] 508 [20.0] 508 [20.0] 515.6 [20.3] 515.6 [20.3] 508 [20.0] 508 [20.0]

Figure 2. TCC3018A through TCC3036A (2 of 2)

22

Dimensional Data and Weights

RETURN

SUPPLY

Figure 3. TCC3042A through TCC3060A (1 of 2)

23

Dimensional Data and Weights

SUPPLY

RETURN

954.10 [37-9/16] 1004.90 [39-9/16] 954.10 [37-9/16] 1055.70 [41-9/16] 1004.90 [39-9/16]

41 [90] 47 [105] 46 [102] 42 [92] 44 [98] 41 [90] 48 [105] 47 [104]

62 [137] 76 [168] 78 [172] 63 [138] 66 [146] 69 [152] 80 [177] 79 [175]

46 [102] 58 [127] 59 [130] 46 [102] 49 [109] 52 [115] 61 [134] 60 [132]

30 [67] 36 [79] 35 [77] 31 [69] 33 [73] 31 [68] 36 [79] 36 [76]

673.1 [26.5] 629.92 [24.8] 685.8 [27.0] 635 [25.0] 698.5 [27.5] 635 [25.0] 219 [482] 182 [401] 668.02 [26.3] 629.92 [24.8] 193 [425] 668.02 [26.3] 629.92 [24.8] 217 [479] 193 [425] 225 [495] 222 [490] 698.5 [27.5] 698.5 [27.5] 698.5 [27.5] 635 [25.0] 635 [25.0] 635 [25.0]

179 [395]

Figure 4. TCC3042A through TCC3060A (2 of 2)

24

Mechanical Specifications

General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with R-22. Units shall be UL listed and carry a UL label. All units shall be factory run tested to check cooling operation, fan and blower rotation and control sequence. Units shall be designed to operate at ambient temperatures between 115°F and 55°F in cooling as manufactured. Cooling performance shall be rated in accordance with ARI standards. Unit Casing All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced fiber insulation shall be in the heater section. Foil-faced fiber nsulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARDTM exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Compressor The compressor shall be a hermetically sealed, high efficiency Climatuff® compressor. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include, roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports, and a refrigerant line filter shall be standard. Evaporator Coil -- Internally enhanced 3/8-inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigerant flow. Condenser Coil The Spine FinTMcondenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct-drive, forward-curved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One, direct-drive, statically and dynamically balanced propeller fan shall be used in a drawthrough vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory-installed wood nailer strips. Electric Heaters Each heater assembly shall include power supply fusing if over 48 amps, automatic resetting limit switches and heat limiters for thermal protection. Heaters shall be provided with polarized plugs for quick connection to unit low voltage wiring. Electric heat modules shall be UL listed. Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut-to-length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the downflow economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off" cycle. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit - Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats - Two stage heating/cooling or one stage heating/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setback Thermostat - Programmable electronic thermostat shall provide heating setback and cooling setup with 7-day, programming capability. 1 H/1 C or 2H/2C models available.

Trane

6200 Troup Highway Tyler, TX 75707-9010 An American Standard Company

American Standard has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

25

Information

TCC_PD rev3 Trane.pmd

25 pages

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

794495


You might also be interested in

BETA
TCC_PD rev3 Trane.pmd