DUTY/STAFF STATION

EXECUTONE® 36130-1 and 36130-2

Features Direct Replacement of Previous Model Provides Circuitry for Staff Service Feature on HCP and CARE/ COM II-E Systems with DSP ASI Function Switch Selectable Visual and Audible Indication of Calls Repeated Tone Signal for Emergency Calls Non-Conductive Mounting Screws Connections via IDC Connectors Excellent Voice Pickup Sensitivity

TM

Duty/Staff Station Model 36130-1 (off-white) supersedes CCDSS/W43 Model 36130-2 (gray) supersedes 31960-2 INFOSTAR®/HCP CARE/COM® II-E CARE/COM® II Description Wall recessed or surface mounted duty/ staff station with call origination facility and two-way voice communication between utility area and nurse control station or Staff Terminal. Provides additional circuitry needed to support the Staff Service feature on HCP and CARE/COM II-E systems using the new DSP ASI. Provides visual and audible indication of normal, emergency, and code blue calls in system when duty mode is selected. Mode of operation is switch selectable. When set in staff mode, the station has communication with the NCS but does not receive indication of patient calls. Controls and Indicators One nurse CALL button and indicator, one combination red intercom indicator and CANCEL button, one PATIENT call indicator. Tone signals announce incoming calls. Repeating tone signals announce unanswered calls. Interrupted tone signals indicate emergency calls. Circuitry Solid state switching with high reliability relays for audio switching. Speaker/Microphone Dynamic 2-¼" (5.72 cm) cone type with Alnico V magnet and voice coil impedance of 45 ohms. Optional Backbox Adapter Kit The duty/staff station can be wall mounted into existing recessed W1, W2, or W330 type backbox by using a semi-flush faceplate adapter kit, Model AA38574-OW. Housing and Finish Faceplate: High-impact, molded thermoplastic finish in grey color, supplied with nylon screws for mounting. S43 Housing: Three-gang backbox for surface mounting. Dimensions Faceplate: Faceplate 6-3/8" (16.19 cm) wide x 4-½" (11.43 cm) high S43 Housing: 6-½" (16.51 cm) wide x 4-¾" (12.07 cm) high x 2-¾" (6.99 cm) deep, supplied by others W43 Backbox: 8-13/16" (22.38 cm) wide x 4-½" (11.43 cm) high, electrical box with three-gang adapter for total depth of 3-5/16" (8.41 cm), supplied by others. Mounting Height 4.5' from floor Listings & Approvals

TS53010/0602 Page 1 of 2

DUTY/STAFF STATION

EXECUTONE® EXECUTONE ® 36130-1 and 36130-2 FUTURA II HPNPCS/W43W(GR3)

Architect & Engineering Specifications

Duty/Staff Station - The wall recessed or surface mounted duty/staff station shall contain the facility for call origination to the nurse control station or Staff Terminal and shall automatically indicate all normal patient, emergency, and code blue calls when in the duty mode. Provides additional circuitry needed to support the Staff Service feature on HCP and CARE/COM II-E systems using the new DSP ASI. The station shall provide two-way voice communication with the nurse control station. The mode of operation shall be switch selectable. When set in staff mode, the station has communication with the NCS but does not receive indication of patient calls. Operates in conjunction with auxiliary signaling equipment. One patient call indicator lamp shall be provided to indicate patient calls when the station is set for duty mode (steady light shall indicate normal calls and flashing light shall indicate emergency calls). One white combination CALL button and indicator shall be provided to originate a call to the nurse control station. One combination red intercom indicator and CANCEL button shall be provided to cancel calls to the NCS. The red indicator shall be illuminated when intercom line from the NCS to the duty/staff station is engaged. Tone signals shall announce incoming calls. Repeating tone signals shall announce unanswered calls. Interrupted tone signals shall indicate emergency calls. To insure long life and reliability, solid state circuitry shall be used for signal switching. The speaker/microphone shall be a dynamic 2-¼" (5.72 cm) cone type with Alnico V magnet. The impedance of the speaker/microphone's voice coil shall be 45 ohms. For ease of installation and maintenance, the duty/staff station shall plug into prewired edge connectors. All components shall be mounted on a faceplate. For maximum safety against electrical shock, the faceplate shall be fastened to the backbox with nylon screws (furnished with the station unit). The duty/staff station shall be mounted 4.5' fromthe floor. Wall mounting of duty/staff station into existing recessed W1, W2, or W330 type backbox shall be possible using a semi-flush faceplate adapter kit, Model AA38574-OW. The faceplate shall be made of high impact, molded thermoplastic finish, in grey color. The S43 housing shall be a three-gang backbox for surface mounting. The dimensions shall be: Faceplate: 6-3/8" (16.19 cm) wide x 4-½" (11.43 cm) high Housing: 6-½" (16.51 cm) wide x 4-¾" (12.07 cm) high x 2-¾" (6.99 cm) deep, supplied by others. Backbox: 8-13/16" (22.38 cm) x 4-½" (11.43 cm) high, electrical box with three-gang adapter for total depth of 3-5/16" (8.41 cm), supplied by others.

This literature does not cover all the variations in the equipment described, nor does it provide for every possible contingency to be met in connection with installation, operation and maintenance. All specifications and listings are subject to change without notice. © 2002 TEPG-US (a Tyco Company). All rights reserved. Tyco, the "Globe" design, INFOSTAR, CARE/COM, and Executone are trademarks owned or used under license by Tyco International Services AG or its affiliates in the U.S. and/or other countries.

www.simplexgrinnell.com

TS53010/0602 Page 2 of 2

Information

Catalog Page TS53010 Duty/Staff Station

2 pages

Find more like this

Report File (DMCA)

Our content is added by our users. We aim to remove reported files within 1 working day. Please use this link to notify us:

Report this file as copyright or inappropriate

1077625


You might also be interested in

BETA
Catalog Page TS53010 Duty/Staff Station
Microsoft Word - Pro700SpecificationMay2009.doc