Read untitled text version

GRUNDFOS DATA BOOKLET

MMS

Rewindable submersible motors and accessories 50/60 Hz

Contents

General data

MMS rewindable motors Product range, 50 Hz Product range, 60 Hz Rewindable motors Type key High motor efficiency Overtemperature protection Protection against upthrust Motor protection range and tools for communication Operation Name plate Voltage quality Operating conditions Insulation class 3 4 4 4 4 4 4 5 5 5 5 5 6 6

Sizing of cable Cable termination kit, type KM Cable termination kit Submersible drop cable Pt100

40 41 41 41 42

Order data

3 x 220 V, 60 Hz 3 x 220-230 V, 50 Hz 3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz 3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz 3 x 500 V, 50 Hz and 3 x 575 V, 60 Hz 3 x 380 V, 60 Hz, PVC windings 3 x 380 V, 60 Hz, PE/PA windings 43 44 45 46 47 48 49

Further product documentation Construction

Material specification for MMS 6000 to MMS 12000 Pump connection Shaft and radial bearing Shaft seal Motor Stator Thrust bearing Upthrust bearing Diaphragm Motor liquid 7 8 8 8 8 9 9 9 9 9 WinCAPS WebCAPS 50 51

Technical data

MMS 6000 (N) MMS 8000 (N) MMS 10000 (N) MMS 12000 (N) 10 11 12 13

Electrical data

3 x 220 V, 50 Hz 3 x 230 V, 50 Hz 3 x 380 V, 50 Hz 3 x 400 V, 50 Hz 3 x 415 V, 50 Hz 3 x 500 V, 50 Hz 3 x 220 V, 60 Hz and 3 x 380 V 60 Hz 3 x 460 V, 60 Hz and 3 x 575 V, 60 Hz 14 14 15 16 17 18 19 20

Installation

Wiring diagram 21

Accessories

CU 3 Complete borehole monitoring system with CU 3 and SM 100 G100 - Gateway for communication with Grundfos products Cables 22 30 31 33

2

General data

MMS rewindable motors

The Grundfos MMS product range is a complete range of submersible, rewindable motors, available in sizes from 3.7 kW 6" up to 250 kW 12" motors. Two material versions are available. A cast iron version EN-JL1040. For more aggressive liquids with a moderate content of salt, an N-version made of stainless steel DIN/EN 1.4401 (AISI 316) is available. Connections and shafts of the 6" and 8" motors are designed according to NEMA standards. The 10" and 12" motors are designed according to the drawings shown on page 8. MMS motors comply with the same standards as Grundfos MS motors and can therefore be fitted on all Grundfos SP pumps without the need for adapters. The motor production is in the hands of experts with many years of experience within the manufacture of motors. In order to make the time of delivery as short as possible, components are manufactured for stock, enabling rapid assembly of a few basic components into the finished motor. The rewindable motor construction means low costs of repair of the motor in case of damage. Moreover, as rewinding can be effected locally, unnecessary time for transportation of the motor can be avoided and possible periods of downtime reduced to a minimum. The construction of the motor, based on few basic components, also facilitates service and repair of the motor. Fitted with a sturdy MICHELL thrust bearing, which also functions as an upthrust bearing, all motors offer reliable operation. In order to achieve maximum protection of the motor against burnout, all motors can be fitted with a Pt100 sensor. Combined with a relay and an optional Grundfos CU 3 control unit, the Pt100 provides optimum protection of the motor.

MMS

N

TM01 7873 4999

3

General data

Product range, 50 Hz

MMS 6000 (N) MMS 8000 (N) 8" Power range, direct-on-line and star-delta - 3 x 220-230 V - 3 x 380-415 V 3.7-37 kW 7.5-37 kW 22-63 kW 22-110 kW 75-110 kW 75-190 kW 147-250 kW MMS 10000 (N) 10"

MMS

MMS 12000 (N) 12"

Motor size

6"

- 3 x 500 V

Allowed installation

- Vertical - Horizontal 3.7- 37 kW 3.7- 30 kW 22-110 kW 22-92 kW 75-190 kW 75-170 kW 147-250 kW 147-190 kW

Product range, 60 Hz

MMS 6000 (N) MMS 8000 (N) 8" 22-75 kW 22-110 kW 22-110 kW 22-110 kW MMS 10000 (N) 10" 75-132 kW 75-190 kW 75-190 kW 75-190 kW

Motor size

- 3 x 220 V - 3 x 380 V - 3 x 460 V - 3 x 575 V

6" 3.7-37 kW 3.7-37 kW 3.7-37 kW

Power range, direct-on-line and star-delta

Power range, direct-on-line

Allowed installation

- Vertical - Horizontal 3.7- 37 kW 3.7- 30 kW 22-110 kW 22-92 kW 75-190 kW 75-170 kW

Rewindable motors

The two pole MMS motors are easily rewinded. The windings of the stator are made of a special water-proof wire of pure electrolytic copper sheathed with special non-hydroscopic thermoplastic material. The high dielectric strength properties of this material allow direct contact between the windings and the liquid for efficient cooling of the windings.

High motor efficiency

The complete motor range offered by Grundfos is characterized by high efficiency, which contributes to improved economy of the total pump system.

Overtemperature protection

For protection against overtemperature, Grundfos offers the Pt100 temperature sensor as an optional extra. The Pt100 is fitted in the motor and connected via a relay, which can be connected to the CU 3 control unit. When the temperature becomes too high, the motor will be cut out and damage to the pump be avoided. Restart of the motor after cut-out can be achieved in two ways: · manual restart or · automatic restart. Automatic restart means that the CU 3 attempts to restart the motor after 15 min. If the first attempt is not successful, restarting will be reattempted at 30-minute intervals.

Type key

Example Type range Min. borehole diameter in inches Generation Material: = Cast iron EN-JL1040 N = DIN/EN 1.4401 (AISI 316) MMS 6 000 N

4

General data

Protection against upthrust

In case of a very low counter pressure in connection with start-up, there is a risk that the entire pump body may rise, for instance in connection with fountain applications. This is called upthrust, and it may cause damage to both pump and motor. Therefore, the MMS motors are fitted with upthrust spacers, which prevent upthrust in the critical start-up phase. The maximum load in connection with thrust and upthrust can be seen in the table below.

Motor power [kW] (hp) Min. 6" 8" 10" 12" 3.7 (5) 18.5 (25) 22 (30) 75 (100) 132 (180) Max. 15 (20) 37 (50) 110 (150) 190 (260) 250 (340) Thrust (*) [N] 15000 27500 60000 60000 70000 (**) [N] [N] 6000 6000 12500 12500 15000 Pos. 1 2 3 4 5 6 7 8 9 10 Description Type designation Product number Production data (MMYY) Motor data, 50 Hz Motor data, 60 Hz Duty conditions Weight Model type Internatinal Electrotechnical Commision standard Enclosure Class Code MMS 8000 Upthrust

MMS

Name plate

1

MMS 8000 PROD. No. 96430674 0404

75 KW SF. 1,0 50 HZ 3 ~ VOLT 380 MAX. AMPS 156 0,890 COS Ø /PF 2900 RPM 75 KW SF. 1,15 60 HZ 3 ~ VOLT 440 MAX. AMPS 154 0,890 COS Ø /PF 3490 RPM

S1/30 C 0,5 m/s - 1.6 ft/s IEC 34 WEIGHT 237 Kg / 522 LB IP58 MODEL B

2 3

4

400 152 0,860 2910 460 150 0,880 3500

415 152 0,840 2920 480 148 0,850 3510

5 6 7 8

Motor type

°

Made in EU,I

9 10

PROD. No 96430674 0404 See name plate See name plate S1/30°C 0.5 m/s-1.6 ft/s 237 kg/522 LB Model B IEC 34 IP 58

(*) Double direction of rotation (clockwise and counterclockwise) (**)Direction of rotation to be specified (counterclockwise)

Motor protection range and tools for communication

Description Pt100 including relay CU 3 R100 RS-485 communication module SM 100 sensor module G100 Power 3.7-190 kW 220- 250 kW

Voltage quality

The required voltage quality for Grundfos MMS submersible motors, measured at the motor terminals, is ­10%/+6% of the nominal voltage during continuous operation (including variations in the supply voltage and losses in cables).

Operation

Frequency of starts and stops

Motor type MMS 6000 Number of starts Minimum 1 per year is recommended Maximum 15 per hour Maximum 360 per day Minimum 1 per year is recommended MMS 8000 Maximum 10 per hour Maximum 240 per day Minimum 1 per year is recommended MMS 10000 Maximum 8 per hour Maximum 190 per day Minimum 1 per year is recommended MMS 12000 Maximum 5 per hour Maximum 120 per day

N

TM01 8447 0200

TM01 7408 1204

5

General data

Operating conditions

Cooling The cooling of the motor depends on the temperature and the flow velocity of the pumped liquid past the motor. To ensure sufficient cooling, the values for maximum temperature of the pumped liquid and its flow velocity must be kept. It is reccomended always to ensure a minimum cooling flow of 0.15 m/s. Free convection Free convection is achieved when the diameter of the borehole is at least 2" (~ 50 mm) bigger than the outer diameter of the motor. The motor must always be installed above the borehole screen. If a flow sleeve is used, the motor can be placed in the screen. Calculation of the flow velocity: Q min v = -------------------------------------------------- m/s 2 2 2826 × D i ­ d A Required data: Qmin: Flow in m3/h Di: Borehole diameter in m dA: Motor diameter in m.

1.1 1.0

Derating factor

MMS

Operating pressure For all motor sizes: Maximum 60 bar. Temperature of pumped liquid Motors with PVC windings can operate at liquid temperatures up to 30°C. When operating in liquids at temperatures from 20°C to 43°C, the motor can be derated according to the curve below.

PVC windings

0.9 0.8 0.7 0.6 15 20

v

=

v

0 m /s

=

v

0.

=

15

0.

5

m

m

/s

/s

TM01 6934 3899 TM01 6935 3899

25

30

35

40

45

50

Temperature [°C]

Motors with PE/PA windings can operate at temperatures up to 50°C. For liquid temperatures from 35°C to 50°C, the motors with PE/PA windings can be derated according to the curve below.

PE/PA windings

1.1 1.0

Derating factor

v= v=

0.5 /s

0.9 0.8 0.7 0.6

v=

0.1

0m /s

5m

m/

s

Dmotor

TM02 2269 4001

N

Dborehole Maximum liquid temperature:

Motor Grundfos 6" to 12" rewindable Installation Flow velocity past motor 0.15 m/s 0.50 m/s Vertical 25°C 30°C

30

35

40

45

50

55

60

Temperature [°C]

Insulation class

PVC windings: Y PE/PA windings A. Enclosure class Enclosure class: IP 58 IP 68 (on request).

Horizontal 25°C 30°C

Note: For MMS 6000, 37 kW, MMS 8000, 110 kW, and MMS 10000, 170 kW, the maximum liquid temperature is 5°C lower than the values stated in the table above. For MMS 10000, 190 kW the temperature is 10°C lower.

6

Construction

Material specification for MMS 6000 to MMS 12000

Cast iron version

Pos. Component 202 Shaft 202a Shaft ends Material Steel Stainless steel DIN/EN 1.4462

MMS

Example: MMS 10000

6" 3.7-15 kW Hardened steel/ Thrust bearing 12" EPDM 203/ Stationary/ro206 6" 18.5-37 kW tating part Ceramic/carbon 8"-10" 204 Bearing ring 6"-10" 12" Carbon Stainless steel/NBR Cast iron CR Cast iron Stainless steel EPDM Ceramic/carbon Cast iron Cast iron ENJL1040 ENJL1040 ENJL1040 1.4401 ENJL1040

220

205 Bearing housing, upper 212 Diaphragm 213 Motor end shield 218 Motor sleeve 220 Motor cable 226 Shaft seal 235 Intermediate housing 236 Bearing housing, lower

226

202a

204 205

N-version

Pos. Component 202 Shaft 202a Shaft ends 6" 3.7-15 kW Material Steel Stainless steel Hardened steel/ EPDM DIN/EN 1.4462

235 202

Thrust bearing 12" 203/ Stationary/rotat206 6" 18.5-37 kW ing part Ceramic/carbon 8"-10" 6"-10" 204 Bearing ring 12" Carbon Stainless steel/ NBR Stainless steel CR Stainless steel Stainless steel EPDM

218

236

1.4401 1.4401 1.4401

205 Bearing housing, upper 212 Diaphragm 213 Motor end shield 218 Motor sleeve 220 Motor cable 226 Shaft seal 235 Intermediate housing 236 Bearing housing, lower

202a

Ceramic/carbon Stainless steel Stainless steel 1.4401 1.4401

206 203

213

212

TM01 4985 0404

7

Construction

Pump connection

MMS 6000 and MMS 8000 have connections according to NEMA standard MG 1-18.413. MMS 10000 and MMS 12000 connections are according to the drawings to the right. The cable outlet of motors for star-delta starting are displaced by 90°.

50

MMS

MMS 6000 connection

45° 45°

Shaft and radial bearing

The stainless steel splined shaft end of the 6" and 8" motors fulfills ANSI B92.1, 1970, class 5. 6" motors have 15-teeth module. Pressure angle 30°. 8" motors have 23-teeth module. Pressure angle 30°. 10" and 12" motor shafts have keys. The bearing system for the 6", 8" and 10" motors is stainless steel shaft against carbon bearing rings. The radial bearing rings of the 12" motors are made of stainless steel and NBR.

ø111.2

M12

MMS 8000 connection

ø18

Shaft seal

ø152.5

TM01 8177 1104 TM01 7330 4902 TM01 7328 4902

The mechanical shaft seal is available in two variants: Ceramic/carbon and SiC/SiC. SiC/SiC is according to DIN 24960 and available for motors wounded for · 3 x 380-415 V, 50 Hz, · 3 x 380 V, 60 Hz and · 3 x 460 V, 60 Hz only. The material features high wear resistance and long durability, which ensures tightness and thereby limited replacement of the motor liquid. This is important when the pumped liquid contains sand. Together with the shaft seal housing, the sand shield forms a labyrinth seal, which during normal operating conditions prevents penetration of sand particles into the shaft seal.

4 x ø21

45°

45°

MMS 10000 connection

ø190.5

ø43 9.52 47.6

9.52

Motor

MMS motors 18.5 kW and up have a squirrel cage rotor with copper bars brazed to the short circuit rings by a silver alloy. Note: MMS 6000 motors up to 15 kW have a cast aluminium squirrel cage rotor. The rotor is dynamically balanced for smooth and vibration-free operation.

45 °

78

68

95

MMS 12000 connection

ø21

10

16

59

ø190.5

8

TM01 8178 1104

Construction

Stator

The stator is a wet-wound construction in stainless steel to protect the motor, even in corrosive water. The stator design allows complete access to the winding for easy maintenance and rewinding. The construction of the laminations minimizes operating losses and improves motor performance. In 6", 8", and 10" motors, the motor end shield is screwed onto the stator. A suitable centring assures alignment of rotor and stator.

MMS

Motor liquid

The motor is filled with glycerol-containing motor liquid, which is frost-proof down to ­20°C. The motor liquid has an anti-corrosive and lubricating function. To obtain the best protection, a concentration of 40% to 60% in water is recommended. Should the glycerol-containing motor liquid mixed with water not be allowed for special applications, MMS motors may be filled even with fresh water. Motors not filled with motor liquid are available on request. The following table indicates the freezing points obtainable with various percentages of glycerolcontaining motor liquid.

.

Thrust bearing

The MICHELL type of water-lubricated thrust bearing is very simple and most efficient. The thrust capacity of the bearings is in accordance with NEMA standards for submersible motors, where these are applicable. See drawing to the right.

Glycerol-containing motor liquid % volume 40 50 60 70 80 90 100

Freezing point [°C] ­3,9 ­11,5 ­15,2 ­20 ­26,7 ­36,5 ­46,5

Upthrust bearing

The EPDM upthrust spacers placed above the rotating bearing part prevent motor damage during transportation or in case of upthrust in connection with start-up. The upthrust bearing is an integrated part of the thrust bearing.

Diaphragm

The diaphragm (pos. no. 3) is fitted between the stator and the motor end shield. The diaphragm is dimensioned to equalize pressure variations caused by temperature rises in connection with intermittent operation. Example: MMS 8000

1

2

3

TM01 7331 0604

1. Rotating bearing part 2. Stationary bearing part Diaphragm.

9

Technical data

MMS 6000 (N)

MMS 6000 (N)

45°

45°

50

Ø144

Ø25.2 M12 23 Ø76

Ø111.2

L

73

Motor power P2 [kW] 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 P2 [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50

L [mm] 630 660 690 720 780 915 975 1085 1195 1315 1425 1425

Weight [kg] 45 48 50 55 60 72 78 90 100 115 125 125

Shipping volume [m3] 0.077 0.077 0.077 0.077 0.077 0.108 0.108 0.108 0.108 0.123 0.123 0.123

Cables The 6" motors are connected by means of three singlecore cables, approved for use with drinking water. All cables are round. The cable outlet of star-delta motors are displaced by 90°.

Being an integrated part of the motor, the motor cable cannot be fitted/removed once the motor is assembled. Cable length: 5 m. Note: Sizing of the motor cable requires that it is submerged in water.

Cross-section [mm2] Motor power 3 x 220 V, 60 Hz DOL P2 [kW] 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 P2 [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 3x1 6 6 6 6 6 6 6 10 10 10 10 10 SD 6x1 3 x 220-230 V, 50 Hz DOL 3x1 6 6 6 6 6 6 6 10 10 10 10 SD 6x1 6 6 6 6 6 6 6 6 6 6 6 10 3 x 380-415 V, 50 Hz 3 x 460 V, 60 Hz DOL 3x1 6 6 6 6 6 6 6 6 6 10 10 10 SD 6x1 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 10 10 10 6 6 6 6 6 6 6 6 6 6 3 x 500 V, 50 Hz DOL 3x1 SD 6x1 3 x 380 V, 60 Hz DOL 3x1 6 6 6 6 6 6 6 6 6 10 10 10 6 SD 6x1

Outer dimensions

Cross-section [mm2] 6 10 Type of cable Round Round Outer dimensions, max. [mm] 8.1 8.8

10

TM01 7325 3505

Technical data

MMS 8000 (N)

Ø18

MMS 8000 (N)

68

Ø38.1 Ø152.5

TM01 7326 1104

45°

45°

Ø192

45

L

101.6

Motor power P2 [kW] 22 26 30 37 45 55 63 75 92 110 P2 [hp] 30 35 40 50 60 75 85 100 125 150

L [mm] 1010 1050 1110 1160 1270 1350 1490 1590 1830 2060

Weight [kg] 126 134 146 156 177 192 218 237 283 333

Shipping volume [m3] 0.156 0.156 0.156 0.156 0.156 0.187 0.187 0.187 0.239 0.239

Cables The 8" motors are connected by means of three singlecore cables, approved for use with drinking water. All cables are round. The cable outlet of star-delta motors are displaced by 90°.

Being an integrated part of the motor, the motor cable cannot be fitted/removed once the motor is assembled. Cable length: 8 m. Note: Sizing of the motor cable requires that it is submerged in water.

Cross-section [mm2] Motor power 3 x 220 V, 60 Hz DOL P2 [kW] 22 26 30 37 45 55 63 75 92 110 P2 [hp] 30 35 40 50 60 75 85 100 125 150 3x1 16 16 16 16 25 25 25 25 SD 6x1 10 10 10 16 16 16 16 16 3 x 220-230 V, 50 Hz DOL 3x1 16 16 16 16 25 25 25 SD 6x1 10 10 10 16 16 16 16 3 x 380-415 V, 50 Hz 3 x 460 V, 60 Hz DOL 3x1 16 16 16 16 16 16 16 16 25 25 SD 6x1 10 10 10 10 10 16 16 16 16 16 3 x 500 V, 50 Hz 3 x 575 V, 60 Hz DOL 3x1 16 16 16 16 16 16 16 16 25 25 SD 6x1 10 10 10 10 10 16 16 16 16 16 3 x 380 V, 60 Hz DOL 3x1 16 16 16 16 16 16 16 16 25 25 SD 6x1 10 10 10 10 16 16 16 16 16 16

Outer dimensions

Cross-section [mm2] 10 16 25 Type of cable Round Round Round Outer dimensions, max. [mm] 8.8 10.7 12.1

Ø127

11

Technical data

MMS 10000 (N)

MMS 10000 (N)

Motor power P2 [kW] 75 92 110 132 147 170 190 P2 [hp] 100 125 150 180 200 230 260

L [mm] 1400 1500 1690 1870 2070 2220 2400

Weight [kg] 280 330 385 435 500 540 580

Shipping volume [m3] 0.415 0.415 0.415 0.494 0.494 0.564 0.564

Cables The 10" motors are connected by means of three single-core cables, approved for use with drinking water. All cables are round. The cable outlet of star-delta motors are displaced by 90°.

Being an integrated part of the motor, the motor cable cannot be fitted/removed once the motor is assembled. Cable length: 8 m. Note: Sizing of the motor cable requires that it is submerged in water.

Cross-section [mm2] Motor power 3 x 220 V, 60 Hz DOL P2 [kW] 75 92 110 132 147 170 190 P2 [hp] 100 125 150 180 200 230 260 3x1 50 50 50 50 SD 6x1 3 x 220-230 V, 50 Hz DOL 3x1 50 50 50 SD 6x1 35 35 35 3 x 380-415 V, 50 Hz 3 x 460 V, 60 Hz DOL 3x1 50 50 50 50 50 50 50 SD 6x1 35 35 35 35 35 35 35 3 x 500 V, 50 Hz 3 x 575, 60 Hz DOL 3x1 50 50 50 50 50 50 50 SD 6x1 35 35 35 35 35 35 35 3 x 380 V, 60 Hz DOL 3x1 50 50 50 50 50 50 50 SD 6x1 35 35 35 35 35 35 35

Outer dimensions

Cross-section [mm2] 35 50 Type of cable Round Round Outer dimensions, max. [mm] 14.2 16.1

12

TM01 7327 3701

Technical data

MMS 12000 (N)

MMS 12000 (N)

ø190.5

ø21

45

90

4

L

127

Motor power P2 [kW] 147 170 190 220 250 P2 [hp] 200 230 260 300 340

L [mm] 1790 1880 1980 2140 2290

Weight [kg] 565 605 650 700 775

Shipping volume [m3] 0.564 0.564 0.564 0.564 0.564

Cables The 12" motors are connected by means of three single-core cables, approved for use with drinking water. All cables are round. The cable outlet of star-delta motors are displaced by 90°. Being an integrated part of the motor, the motor cable cannot be fitted/removed once the motor is assembled. Cable length: 8 m. Note: Sizing of the motor cable requires that it is submerged in water.

Cross-section [mm2] Motor power P2 [kW] 147 170 190 220 250 P2 [hp] 200 230 260 300 340 3 x 380-415 V, 50 Hz DOL 3x1 70 70 70 70 70 SD 6x1 50 50 50 50 50 3 x 500 V, 50 Hz DOL 3x1 70 70 70 70 70 SD 6x1 50 50 50 50 50

Outer dimensions

Cross-section [mm2] 50 70 Type of cable Round Round Outer dimensions, max. [mm] 16.1 18.5

TM01 7329 3505

100

ø55

31

ø127 ø232

ø286

13

Electrical data

3 x 220 V, 50 Hz

Motor Type Size Power [kW] 3.70 5.50 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 Full-load current In [A] 17.4 24.8 32.5 39.5 46.0 53.0 60.5 69.5 82.5 100 114 144 84.5 99.5 114 138 166 212 218 280 350 405 Motor efficiency [%] 50% 69 76 79 78 79 82 83 85 85 85 86 86 81 81 83 84 85 85 87 84 84 85 75% 71 76 79 79 79 82 83 85 85 85 86 86 84 83 85 86 88 87 89 86 86 86 100% 70 74 77 76 77 79 81 83 83 84 84 84 84 83 85 86 88 88 88 86 86 85 Cos 50% 0.70 0.70 0.68 0.71 0.73 0.72 0.73 0.81 0.80 0.72 0.74 0.67 0.76 0.80 0.76 0.78 0.69 0.64 0.84 0.78 0.72 0.84 Power factor Cos 75% 0.80 0.80 0.79 0.81 0.82 0.82 0.82 0.87 0.87 0.82 0.83 0.79 0.83 0.85 0.83 0.84 0.79 0.76 0.89 0.85 0.81 0.88

3 x 220 V, 50 Hz

Cos 100% 0.84 0.83 0.83 0.85 0.85 0.85 0.85 0.89 0.88 0.86 0.87 0.84 0.86 0.86 0.86 0.86 0.85 0.82 0.90 0.87 0.85 0.88

I st -----I n 3.7 3.5 3.5 3.3 3.5 3.6 3.7 5.1 4.9 4.5 4.5 4.7 4.8 4.5 5.2 5.3 5.6 5.4 5.4 5.3 5.2 5.4

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

3 x 230 V, 50 Hz

Motor Type Size Power [kW] 3.70 5.50 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 Full-load current In [A] 17.2 24.2 32.0 38.5 45.5 52.5 58.5 67.0 79.5 100 112 146 82.5 95.5 110 134 168 214 210 270 345 385 Motor efficiency [%] 50% 0.64 0.63 0.61 0.64 0.66 0.65 0.66 0.76 0.75 0.63 0.66 0.59 0.71 0.76 0.71 0.73 0.62 0.57 0.81 0.72 0.65 0.80 75% 0.75 0.75 0.74 0.76 0.81 0.77 0.78 0.85 0.84 0.76 0.78 0.73 0.80 0.83 0.80 0.82 0.74 0.70 0.87 0.81 0.77 0.86 100% 0.82 0.81 0.80 0.82 0.83 0.82 0.83 0.88 0.87 0.83 0.84 0.80 0.84 0.86 0.84 0.85 0.81 0.77 0.90 0.85 0.82 0.88 Cos 50% 67 75 78 77 78 81 82 85 85 84 85 85 80 81 83 83 84 84 87 84 83 85 Power factor Cos 75% 71 76 79 78 79 82 83 85 85 85 85 86 84 84 85 86 87 87 89 86 85 86 Cos 100% 70 74 77 77 78 80 81 83 84 84 84 84 84 84 86 86 88 88 89 86 86 86 I st -----I n 4.0 3.7 3.7 3.6 3.7 3.8 3.8 5.3 5.2 4.7 4.8 4.8 5.3 5.1 5.7 5.7 6 5.9 5.7 5.4 5.6 5.7

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

14

Electrical data

3 x 380 V, 50 Hz

Motor Type Size Power [kW] 3.70 5.50 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 75.0 92.0 110 132 147 170 190 147 170 190 220 250 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 Full-load current In [A] 10.0 14.4 18.6 22.8 27.0 30.5 35.0 40.5 48.5 57.0 65.5 83.0 50.0 59.0 66.5 81.5 95.5 116 132 156 194 230 160 198 323 275 315 365 420 310 350 390 450 515 Motor efficiency [%] 50% 69 76 79 78 79 82 83 85 85 86 86 85 80 80 82 83 85 85 86 86 87 86 85 85 85 86 85 85 85 84 85 85 86 86 75% 71 76 79 79 79 82 82 85 85 85 85 85 82 82 84 84 86 86 87 87 88 87 87 87 87 88 87 87 87 87 87 88 88 88 100% 69 74 77 76 77 79 80 84 84 83 83 82 82 81 83 84 86 86 86 86 86 86 87 87 87 88 88 87 87 88 88 88 88 88 Cos 50% 0.70 0.70 0.69 0.72 0.73 0.72 0.74 0.73 0.74 0.76 0.76 0.71 0.78 0.80 0.79 0.79 0.76 0.79 0.78 0.78 0.80 0.80 0.77 0.75 0.77 0.79 0.73 0.73 0.69 0.75 0.77 0.77 0.78 0.78 Power factor Cos 75% 0.80 0.80 0.79 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.81 0.84 0.86 0.85 0.85 0.84 0.86 0.86 0.85 0.86 0.87 0.84 0.83 0.84 0.85 0.82 0.82 0.79 0.83 0.85 0.85 0.85 0.86

3 x 380 V, 50 Hz

Cos 100% 0.84 0.83 0.84 0.85 0.85 0.85 0.86 0.87 0.87 0.88 0.87 0.85 0.86 0.87 0.87 0.87 0.88 0.88 0.89 0.89 0.88 0.89 0.86 0.85 0.86 0.87 0.85 0.85 0.84 0.87 0.88 0.88 0.89 0.89

I st -----I n 3.7 3.5 3.5 3.3 3.5 3.6 3.7 5.1 4.9 4.5 4.5 4.2 4.8 4.5 5.2 5.3 5.6 5.4 5.4 5.2 5.2 5.2 5.3 5.2 5.4 5.3 5.8 5.7 5.8 5.9 5.8 5.8 5.8 5.4

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 12000 (N)

12"

15

Electrical data

3 x 400 V, 50 Hz

Motor Type Size Power [kW] 3.70 5.50 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 75.0 92.0 110 132 147 170 190 147 170 190 220 250 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 Full-load current In [A] 9.85 14.0 18.4 22.4 26.0 30.0 34.0 40.5 47.5 56.0 64.0 80.0 48.0 56.5 64.0 78.5 96.5 114 132 152 186 224 156 194 228 270 315 365 425 305 345 390 445 505 Motor efficiency [%] 50% 67 75 77 77 78 81 82 83 84 85 85 84 80 80 82 82 84 84 85 86 87 86 84 84 85 85 84 84 83 84 85 85 85 85 75% 70 76 79 78 79 81 82 85 85 85 85 85 82 82 84 84 86 86 87 87 88 87 86 87 87 88 87 86 86 87 87 87 87 87 100% 70 74 77 77 78 80 81 84 84 84 84 83 82 82 84 84 86 86 87 87 87 87 87 87 88 88 87 87 87 88 88 88 88 88 Cos 50% 0.63 0.62 0.60 0.64 0.65 0.64 0.66 0.64 0.65 0.68 0.67 0.66 0.72 0.76 0.74 0.74 0.65 0.72 0.66 0.71 0.72 0.73 0.70 0.67 0.70 0.72 0.64 0.64 0.60 0.66 0.69 0.68 0.69 0.69 Power factor Cos 75% 0.75 0.75 0.73 0.76 0.77 0.76 0.79 0.77 0.77 0.79 0.79 0.77 0.81 0.83 0.82 0.82 0.76 0.81 0.78 0.82 0.82 0.83 0.80 0.78 0.79 0.81 0.75 0.75 0.72 0.77 0.79 0.80 0.80 0.80

3 x 400 V, 50 Hz

Cos 100% 0.81 0.81 0.80 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.83 0.84 0.85 0.85 0.85 0.82 0.85 0.83 0.86 0.86 0.87 0.84 0.82 0.84 0.84 0.81 0.81 0.79 0.83 0.85 0.84 0.85 0.85

I st -----I n 4.0 3.7 3.7 3.6 3.7 3.8 3.8 5.3 5.2 4.7 4.8 4.3 5.3 5.1 5.7 5.7 6.0 5.9 5.7 5.8 5.9 5.8 5.4 5.6 5.7 5.7 6.2 6.0 5.9 6.2 6.1 6.2 6.1 5.9

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 12000 (N)

12"

16

Electrical data

3 x 415 V, 50 Hz

Motor Type Size Power [kW] 3.70 5.50 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 75.0 92.0 110 132 147 170 190 147 170 190 220 250 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 Full-load current In [A] 10.0 14.0 19.0 22.6 26.5 30.5 34.0 41.0 48.5 56.0 65.0 79.0 47.5 55.0 63.0 77.0 96.0 112 130 152 186 222 156 196 228 270 320 375 440 315 350 395 450 510 Motor efficiency [%] 50% 66 73 76 75 77 79 80 82 83 84 84 84 79 79 81 82 82 83 83 85 86 85 83 84 84 85 83 83 82 83 84 84 84 84 75% 70 75 78 78 79 81 82 84 84 85 85 85 82 82 84 84 85 86 86 87 87 87 86 86 87 87 86 86 85 86 87 87 87 87 100% 70 74 77 77 78 80 81 84 84 84 84 83 82 82 84 84 86 86 86 87 87 87 87 87 88 88 87 87 86 87 88 88 88 88 Cos 50% 0.57 0.57 0.54 0.57 0.59 0.57 0.60 0.57 0.58 0.60 0.60 0.61 0.67 0.72 0.69 0.69 0.61 0.66 0.63 0.66 0.66 0.67 0.65 0.61 0.64 0.65 0.57 0.57 0.53 0.58 0.61 0.60 0.62 0.62 Power factor Cos 75% 0.70 0.70 0.67 0.70 0.72 0.71 0.73 0.71 0.72 0.74 0.73 0.74 0.77 0.80 0.79 0.79 0.73 0.77 0.76 0.78 0.81 0.78 0.76 0.73 0.75 0.76 0.70 0.69 0.66 0.71 0.74 0.73 0.74 0.74

3 x 415 V, 50 Hz

Cos 100% 0.78 0.77 0.75 0.77 0.79 0.78 0.80 0.79 0.79 0.81 0.81 0.81 0.82 0.84 0.83 0.83 0.80 0.83 0.82 0.84 0.83 0.84 0.81 0.79 0.81 0.81 0.77 0.77 0.74 0.79 0.81 0.80 0.81 0.81

I st -----I n 4.0 3.9 3.8 3.7 3.7 3.9 3.9 5.4 5.4 4.9 4.9 4.3 5.6 5.5 6.0 5.9 6.8 6.3 5.9 5.8 6.2 6.0 5.6 5.7 6.0 5.9 6.3 6.0 5.9 6.3 6.3 6.2 6.2 6.1

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 12000 (N)

12"

17

Electrical data

3 x 500 V, 50 Hz

Motor Type Size Power [kW] 7.50 9.20 11.0 13.0 15.0 18.5 22.0 26.0 30.0 37.0 22.0 26.0 30.0 37.0 45.0 55.0 63.0 75.0 92.0 110 75.0 92.0 110 132 147 170 190 147 170 190 220 250 Full-load current In [A] 14.4 17.4 20.4 23.4 26.5 31.5 36.5 44.5 50.5 63.0 37.5 44.0 49.5 60.5 72.0 88.5 96.5 114 142 182 122 150 178 210 236 270 305 218 265 275 335 375 Motor efficiency [%] 50% 78 77 79 82 83 84 85 85 86 86 81 81 83 84 85 86 87 88 88 86 85 85 85 86 85 86 86 86 87 88 88 87 75% 78 78 79 82 83 85 86 85 86 86 83 84 85 85 87 88 89 89 87 88 87 87 87 88 88 88 88 89 89 90 90 90 100% 74 76 77 80 80 84 84 84 84 85 83 83 85 85 87 88 88 88 88 88 87 87 88 87 88 88 87 90 90 91 90 91 Cos 50% 0.73 0.69 0.71 0.69 0.76 0.70 0.77 0.68 0.72 0.68 0.79 0.80 0.78 0.82 0.73 0.71 0.82 0.85 0.81 0.67 0.77 0.74 0.76 0.82 0.74 0.78 0.80 0.80 0.74 0.85 0.79 0.75 Power factor Cos 75% 0.82 0.80 0.81 0.80 0.84 0.81 0.85 0.79 0.82 0.79 0.85 0.85 0.85 0.87 0.82 0.81 0.88 0.89 0.87 0.78 0.84 0.82 0.84 0.87 0.83 0.85 0.86 0.88 0.82 0.91 0.86 0.85

3 x 500 V, 50 Hz

Cos 100% 0.85 0.84 0.85 0.84 0.86 0.85 0.87 0.85 0.86 0.84 0.87 0.86 0.86 0.87 0.86 0.86 0.90 0.90 0.89 0.84 0.86 0.85 0.86 0.88 0.86 0.87 0.87 0.91 0.86 0.93 0.88 0.89

I st -----I n 3.2 3.4 4.7 3.7 4.2 5.2 4.9 4.8 4.7 4.9 4.7 4.8 5.6 5.6 6.2 6.1 6.1 5.6 5.3 5.3 5.3 5.3 5.4 5.0 5.8 5.4 5.3 6.9 6.0 7.8 5.8 6.3

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 12000 (N)

12"

18

Electrical data

3 x 220 V, 60 Hz and 3 x 380 V 60 Hz

Motor Type Power Size [kW] 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 22 26 30 37 45 55 63 75 75 92 110 132 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 22 26 30 37 45 55 63 75 92 110 75 92 110 132 147 170 190 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 100 125 150 180 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 Full-load current In [A] 19.6 27.5 37.0 45.0 51.5 60.5 69.0 81.0 96.0 114 130 166 102 118 134 164 192 232 265 315 320 395 470 570 11.4 16.0 21.4 26.0 29.5 35.0 40.5 46.5 55.5 65.5 75.5 94.5 59.0 69.0 77.0 94.0 110 132 152 182 220 260 182 224 265 315 355 415 475 Motor efficiency [%] 50% 75% 100% Cos 50%

3 x 220 V, 60 Hz and 3 x 380 V 60 Hz

Power factor Cos 75% Cos 100%

I st -----I n 4.3 3.8 3.5 3.5 3.5 3.6 3.5 4.6 4.9 4.4 4.4 4.8 4.4 4.3 5.2 5.0 5.7 5.3 4.8 4.8 4.7 4.9 4.5 4.2 4.2 3.8 3.5 3.5 3.6 3.7 3.5 4.7 4.9 4.6 4.7 4.5 4.4 4.4 5.1 4.9 5.5 5.0 5.3 4.7 4.8 5.0 5.0 5.1 4.7 4.8 5.6 5.4 5.7

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

3 x 220 66 74 77 74 79 80 79 82 82 83 84 83 75 75 77 78 80 82 83 83 83 82 82 82 3 x 380 66 74 77 74 79 80 79 82 83 84 84 84 75 75 77 79 81 82 83 84 85 83 82 82 83 84 83 83 82

V, 60 Hz 72 74 77 75 79 77 77 76 81 79 82 80 82 81 84 83 84 84 85 83 85 84 85 84 79 80 79 80 81 82 82 82 84 85 85 85 85 85 86 85 85 84 85 85 85 85 85 84 V, 60 Hz 72 74 77 75 79 77 78 76 81 79 82 80 82 80 85 83 85 84 85 84 85 84 85 83 79 80 79 80 81 82 83 83 85 85 85 86 85 85 86 85 87 86 86 86 85 86 86 87 86 87 86 87 86 87 86 87 86 87

0.68 0.72 0.73 0.74 0.77 0.78 0.82 0.85 0.84 0.77 0.77 0.68 0.80 0.82 0.77 0.77 0.75 0.79 0.84 0.85 0.83 0.77 0.85 0.86 0.69 0.72 0.73 0.75 0.77 0.75 0.78 0.79 0.78 0.78 0.76 0.76 0.80 0.81 0.78 0.79 0.80 0.83 0.81 0.86 0.85 0.84 0.81 0.77 0.84 0.84 0.78 0.75 0.69

0.76 0.80 0.81 0.82 0.84 0.82 0.86 0.88 0.88 0.84 0.84 0.88 0.85 0.87 0.84 0.84 0.83 0.86 0.89 0.89 0.87 0.84 0.88 0.89 0.77 0.80 0.81 0.82 0.84 0.82 0.84 0.85 0.85 0.85 0.84 0.84 0.85 0.86 0.84 0.85 0.86 0.88 0.87 0.89 089 0.89 0.86 0.84 0.88 0.88 0.85 0.83 0.79

0.80 0.83 0.84 0.85 0.86 0.85 0.86 0.88 0.88 0.87 0.87 0.84 0.86 0.87 0.87 0.86 0.86 0.88 0.90 0.90 0.88 0.87 0.89 0.89 0.80 0.83 0.84 0.85 0.86 0.85 0.86 0.87 0.87 0.87 0.87 0.87 0.86 0.87 0.87 0.87 0.88 0.89 0.89 0.90 0.90 0.90 0.88 0.87 0.89 0.89 0.87 0.86 0.85

19

Electrical data

3 x 460 V, 60 Hz and 3 x 575 V, 60 Hz

Motor Type Size Power [kW] 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 22 26 30 37 45 55 63 75 92 110 75 92 110 132 147 170 190 22 26 30 37 45 55 63 75 92 110 75 92 110 132 147 170 190 Power [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 Full-load current In [A] 9.75 13.8 18.0 22.0 25.5 29.5 33.5 39.0 46.0 54.5 62.5 79.0 48.5 56.5 64.0 78.0 92.5 112 126 150 184 220 154 190 224 265 305 355 405 37.5 44.0 49.0 60.5 71.0 86.5 95.5 114 140 176 120 148 176 208 234 270 300 Motor efficiency [%] 50% 75% 100%

3 x 460 V, 60 Hz and 3 x 575 V, 60 Hz

Power factor Cos 50% Cos 75% Cos 100%

I st -----I n 4.2 4.0 3.8 3.7 3.8 4.0 4.0 5.5 5.6 5.0 5.1 4.7 5.3 5.1 5.8 5.5 6.4 5.8 6.0 5.7 6.0 5.8 5.7 5.5 5.8 5.7 6.2 5.9 6.1 4.9 5.0 5.8 5.8 6.5 6.5 6.4 5.8 5.6 5.7 6.1 7.0 7.2 7.4 8.0 8.1 8.3

MMS 6000 (N)

6"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

MMS 8000 (N)

8"

MMS 10000 (N)

10"

3 x 460 V, 60 Hz 64 69 73 76 77 79 74 77 78 80 80 82 80 82 83 85 85 85 84 86 85 86 84 85 75 79 76 80 78 82 80 83 82 85 82 85 83 86 84 86 85 87 84 86 81 85 82 86 82 86 83 86 82 86 82 86 82 85 3 x 575 V, 60 Hz 78 82 78 82 81 84 81 85 84 87 84 87 86 88 86 89 87 89 85 88 82 85 83 86 83 86 84 87 83 86 84 87 84 87

70 74 78 77 79 80 81 85 85 84 85 84 81 81 83 84 86 86 86 87 87 86 87 87 88 88 87 87 87 83 83 85 85 88 89 89 89 88 89 87 87 87 87 88 88 88

0.63 0.63 0.61 0.65 0.65 0.65 0.68 0.65 0.67 0.69 0.68 0.65 0.73 0.77 0.74 0.74 0.71 0.73 0.72 0.72 0.74 0.75 0.72 0.69 0.72 0.73 0.66 0.66 0.62 0.79 0.81 0.79 0.82 0.73 0.72 0.81 0.84 0.82 0.68 0.78 0.76 0.78 0.83 0.76 0.79 0.81

0.74 0.74 0.73 0.76 0.76 0.76 0.78 0.77 0.78 0.80 0.79 0.75 0.81 0.83 0.82 0.82 0.80 0.82 0.82 0.82 0.83 0.83 0.80 0.78 0.80 0.82 0.77 0.76 0.73 0.85 0.85 0.85 0.86 0.82 0.81 0.88 0.89 0.87 0.79 0.84 0.83 0.84 0.87 0.83 0.85 0.86

0.80 0.80 0.79 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.85 0.83 0.84 0.86 0.85 0.85 0.85 0.86 0.86 0.86 0.87 0.87 0.84 0.83 0.84 0.85 0.82 0.82 0.79 0.87 0.87 0.87 0.88 0.86 0.86 0.90 0.91 0.89 0.84 0.87 0.86 0.87 0.88 0.86 0.87 0.87

20

Installation

Wiring diagram

MMS motors are available both for direct-on-line and star-delta starting. Motors for star-delta starting can also be connected for direct-on-line starting. The different wiring diagrams are shown below. MMS motor, direct-on-line starting Connection of MMS wound for direct-on-line starting:

MMS

L1 L2 L3 PE

U

V W PE

M

3

MMS motor, star-delta starting Connection of MMS wound for star-delta starting:

If star-delta starting is not required, but direct-on-line starting is, the MMS motor should be connected as shown below.

TM00 1366 5092

TM00 1365 5092

TM00 1364 5092

21

Accessories

CU 3

The CU 3 control unit is an electronic motor starter for monitoring and protecting installations with rated voltages of 200-575 V, 50 - 60 Hz, and a maximum power consumption of 400 A. The CU 3 monitors the following parameters: · System insulation resistance to earth before start. · Motor current consumption and current unbalance. · Voltage supply. · Phase sequence. The CU 3 protects against: · Dry running (not for certain MS 402 motors). · Incipient motor defect · Too high motor temperature (not for certain MS 402 motors). · Motor burnout. As standard, the CU 3 incorporates: · Time relay for star-delta starting and autotransformer starting. · Relay output for external fault indication. In addition CU 3 can be expanded to offer the following functions: · Remote control R100: Wireless infra-red remote control by means of the R100. This function enables the user to change factory settings and to monitor the installation by calling up actual operating data, e.g. current consumption, supply voltage and operating hours. · External sensors SM 100: Reception of data from external sensors by means of an SM 100 sensor module and control according to the data received, e.g. flow rate, pressure, water level and conductivity. · Communication module: Monitoring and communication via a data BUS (GENIbus), a modem or radio, e.g. PC-based control/monitoring. Technical data Enclosure class: Ambient temp.: Relative humidity: Voltage variation: Frequency: SM 100

192.5 mm 54.5 mm

200 mm

MMS

CU 3 R100

CU 3

192.5 mm

54.5 mm

200 mm

Single-turn transformers, 100-400 A. No monitoring of motor temperature.

IP 20 ­20°C to +60°C

106 mm

100 mm

99%

330 mm

­25/+15% of nominal voltage 45 Hz to 65 Hz

89 mm

50 mm 50 mm

Max. back-up fuse: 10 A Relay output: Approvals: Marking: Max. 415 V, 3 A, AC 1 The CU 3 complies with: VDE, DEMKO, EN, UL and CSA CE.

Signal converter, 1-12 A/20-120 A, with monitoring of motor temperature.

22

TM00 7866 1096

TM01 4020 1102

TM00 7308 1102

GR0244 - GR1911

· Motor temperature.

Accessories

Benefits of CU 3/R100 CU 3 is suitable for all 3-phase submersible motors.

Parameters monitored by CU 3 Temperature Motor current Overvoltage/undervoltage Dry running Phase asymmetry/direction of rotation Energy consumption in kW/h Operating hours Starting delay Restarting delay Star-delta starting These components need not be installed

MMS

Description The actual motor temperature is measured by means of the Pt100. The value measured is transferred via a separate cable to a relay. The motor is stopped when the rated motor current set is exceeded. If the actual value is higher/lower than the value set, the motor is stopped.

Motor starter/protective relay Line monitor

The motor power input is measured on each of the three phases and registered as Level relay an average of these three values. 3 electrodes, electrode cable If the average value is lower than the value set, the motor is stopped. The motor power input is measured on each of the three phases. If the input phase sequence is changed, a fault indication is given. The power is read and accumulated every 10 seconds. The energy consumption is calculated and accumulated every 2 hours. Running when the motor relay is activated. Stopped when the motor is not running. Programmable. Programmable limit of starts/stops. Corresponding to a star-delta time-delay relay. Phase monitoring Counter (not calibrated) Operating-hours counter Time-delay relay Time-delay relay Time-delay relay

23

Accessories

Control functions This table describes the protection provided by CU 3

.

MMS

Control parameters

Function

Problem

Advantages

Ground failure

Temperature

Overvoltage/ undervoltage

Insulation resistance is measured only when motor is not operating. A high-impedance voltage is applied to the motor leads and leakage to ground is measured. If the factoryset value is higher than the one measured the motor cannot be started. The actual motor temperature is measured by means of the Pt100. Via a relay, the signal is sent to the CU 3 where the measured temperature is compared with the factoryset value. Temperature protection requires a submersible motor with a Pt100. If the factory-set values are exceeded, a fault indication is given. If the CU 3 receives a temperature signal, the voltage is no longer monitored, but the motor will continue to run. Therefore, the motor and consequently the pump operation will be affected by voltage variations critical to the life of the motor. If there is no temperature signal, the motor will be stopped in case of overvoltage/undervoltage. The motor power input is measured on each of the three phases. The registered power input is average of these three values. If the factory-set value is exceeded, the motor will stop. The motor power input is measured on each of the three phases. The registered power input is an average of these three values. If the average value is lower than the factory-setting value, the motor will stop. The power input of the motor is measured on each of the three phases. CU 3 and motor are installed so that the phase sequence corresponds to correct direction of rotation. CU 3 monitors changes in the phase sequences.

Damaged or decomposed insulation in motor, cable or cable joint.

Possibility of failure indication on motor, cable and cable joint, service indication.

Overload, frequen starts/ stops, operation against blocked discharge pipe, insufficient flow velocity past the motor.

Longer motor life, safe operating conditions, service indication.

The installation is close to a transformer, the mains do not absorb load variations.

Important installation parameter, possibility of improving operating conditions.

Overload

Incorrect dimensioning of pump/motor, voltage supply failure, defective cable, blocking, wear or corrosion. Pump exposed to dry running or underload, for example caused by wear.

Longer pump lift, safe operating conditions, service indication.

Dry running

Traditional dry-running protection is no longer necessary, no extra cables.

Current unbalance

Phase sequence

Mains load is uneven, incipient motor defect, phase voltages diverging. Two phases are wrongly connected.

Motor protection against overload, service indication. Ensures correct pump performance.

24

Accessories

Features and benefits Selecting the right pump The Grundfos CU 3 control unit and a flowmeter provide for a constant monitoring of energy consumption and performance of the pump thus making it possible to ensure that the right pump is selected for the application in question. The CU 3 control unit makes it possible to choose the borehole(s) to be in operation which offer(s) the lowest operating costs. Choosing the right time for service The constant monitoring by the CU 3 control unit makes it possible to service the pump, i.e. clean it and replace wear parts, at the best possible time. Today service and maintenance work is often carried out at regular intervals or when actual downtime occurs. Both are unlikely to result in an optimum energy-efficient operation.

kWh

Time Time

MMS

Operating costs Operating costs

Time for service Time for service

kWh kWh

Time Time

Time Time

Reducing costs of water treatment By minimizing the risk of overpumping and thus the pumping of impure ground water the costs of water treatment can be reduced to a minimum. Using the Grundfos CU 3 control unit and a sensor it is possible to measure water conductivity in each borehole. This provides for the possibility of selecting the borehole (or boreholes) to be in operation which supplies the best water quality at any time.

Conductivity Conductivity

Time Time

TM 00 7299 1096

TM 00 7298 1096

Avoiding overpumping Using the Grundfos CU 3 control unit and a water level sensor it is possible to carry out test pumping of each borehole. This is done by measuring the water table level and the volume of water which is pumped. The purpose is to ensure that only the water naturally running to the borehole is pumped. As a result operations will provide for optimum efficiency. Consequently, the lives of both borehole and pump will increase, since both water aeration and the risk of ingress of aggressive water are reduced.

TM 00 7297 1096

TM00 7296 1096

25

Accessories

Motor protection via CU 3 Monitoring parameters (Diodes) · Power on · Motor on · Motor temperature · Ground failure · Overload/dry running · Overvoltage/undervoltage · Current unbalance · Direction of rotation

MMS

CU CU 3

Netz ein Motor læuft Massefehler Reset Motortemperatur Phasenfolge Trockenlauf (blinkt) / !berlast (leuchtet) Unterspannung (blinkt) / !berspannung (leuchtet) Stromasymmetrie

Signal converter 1-12 [A], 10-120 [A] or single transformers 100-400 A 3 x 400V, 50 Hz 3 x 500 V, 50 Hz

Control cabinet

Connection to pump. No extra cable required. High-frequency signals.

Ground level

Water level Riser pipe

Submersible motor with Tempcon or Pt100

26

TM 00 7977 1702

Submersible pump

Accessories

Control unit CU 3 with R100 remote control and printer Monitoring parameters (Diodes) · Power on · Motor on · Motor temperature · Ground failure · Overload/dry running · Overvoltage/undervoltage · Current unbalance · Direction of rotation

MMS

CU 3

CU 3 Wireless infra-red

communication

Netz ein Motor læuft Massefehler Reset Motortemperatur Phasenfolge Trockenlauf (blinkt) / !berlast (leuchtet) Unterspannung (blinkt) / !berspannung (leuchtet) Stromasymmetrie

Signal converter 1-12 [A], 10-120 [A] or single transformers 100-400 A 3 x 400V, 50 Hz 3 x 500 V, 50 Hz Control cabinet

R 100 R100

Connection to pump. No extra cable required. Highfrequency signals. Ground level

Inductive flowmeter

Water level Riser pipe

Submersible motor with Tempcon or Pt100

TM 00 7978 1702

Submersible pump

27

Accessories

R100 Menus 0. General 1. Operation

1.1 1.2 Warning and stop indication Indication of automatically reset fault indications. Possibility of start and stop.

Wireless infra-red communication

MMS

CU 3 CU 3

R100 R 100

The R100 offers a number of setting possibilities: 3. Limits Indication and setting of:

3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 Motor temperature Current stop limits Current warning limits Voltage variations Insulation resistance Current unbalance Stop for external sensor Warning limits for external sensor.

4. Installation Setting possibilities:

4.1 Automatic or manual resetting of fault indications 4.2 Release time for fault indications 4.3 Star connection time for star-delta or auto-transformer starting 4.4 Starting delay when first started, e.g. after supply failure 4.5 Minimum start cycle time 4.6 On/off of groundwater lowering function 4.7 Run/stop times for groundwater lowering 4.8 Electronic numbering of CU 3 units 4.9 On/off of power and temperature measuring function 4.10 External sensor type On/off of external analog sensor with or without zero offset Maximum value of external analog sensor 4.11 Groundwater lowering by means of level sensors Filling and emptying function 4.12 On/off of external digital sensor.

Status report All settings and measured values can be transferred to a portable printer via wireless infra-red communication and be printed in a status report.

28

TM00 7982 1302

2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13

Motor temperature Current and voltage values Average supply voltage Average input current of the three phases Actual current unbalance Actual insulation resistance to earth Phase sequence and frequency Actual power input and total power consumption Accumulated number of operating hours Value measured by an external sensor Energy consumption per m3 pumped liquid Actual flow Accumulated flow.

IR - Printer

R100

TM00 7981 1702

2. Status Indication of:

Accessories

Menu structure of the R100 remote control

MMS

Start Set Light 0. Generel l. Operation Contrast 2. Status 3. Limits 4. Installation

1.1

2.1

3.1

4.1

1.2

2.2

3.2

4.2

2.3

3.3

4.3

2.4

3.4

4.4

2.5

3.5

4.5

2.6

3.6

4.6

2.7

3.7

4.7

2.8

3.8

4.8

2.9

4.9

2.10

4.10

2.11

4.11

2.12

4.12

TM01 0226 0201

2.13

29

Accessories

Complete borehole monitoring system with CU 3 and SM 100

Monitoring parameters (Diodes) · Power on · Motor on · Motor temperature · Ground failure · Overload/dry running · Overvoltage/undervoltage · Current unbalance · Direction of rotation

Gateway not Protokollsupplied umsetzer with the unit)

(bauseits) CU3 CU3 CU3

MMS

SM 100 The SM 100 sensor module can be connected to eight analog sensors and have eight digital inputs for sensors, e.g. monitoring of pH value conductivity O2 pressure etc.

SM100

GRUNDFOS-GENIbus

max. 1200 m

PC

PC (not supplied with the unit)

CU 3

SM 100

Communication module

Gateway (not supplied with the unit)

Maximum connection to the GENIbus: · 28 CU 3 units, or · 14 CU 3 units and 14 SM 100 units, or · 27 CU 3 and 1 SM 100.

Signal converter 1-12 [A], 10-120 [A] or single-turn transformers 100-400 A 3 x 400 V, 50 Hz 3 x 500 V, 50 Hz

RS-485

Product numbers

Digital inputs

CU 3 - 3 x 400 V Product number 62500293 62500294 62500295 Current range for signal converter [A] 1-12 10-120 100-400

Control cabinet

For analog sensors

Connection to pump No extra cable required High-frequency signals

CU 3 expansion possibilities

Ground level

Product Sensor module SM 100 Communication module RS 485

Range 3 x 400 [V] 1 - 12 [A] 10 - 120 [A] 100 - 400 [A]

Product number 00626191 00626159 00625333 00620480 00620497 00620498 00626148

Inductive flowmeter

Remote control R100 HP printer for R100 Signal converter

TM00 7979 1702

Water level Riser pipe

Submersible pump

Single-turn transformers

Submersible motor with Tempcon or Pt100

30

TM00 7980 1702

Accessories

G100 - Gateway for communication with Grundfos products

The G100 offers a wide selection of options for integration of Grundfos products provided with GENIbus interface into main control and monitoring systems. The G100 enables a pump installation to meet future demands for optimum pump operation in terms of reliability, operating costs, centralization and automation.

MMS

Central management system PROFIBUS-DP INTERBUS-S

Modem SMS

Radio

PLC

Direct

Radio

Main network

POWER POWER MNC POWER GENI GENI TxD GENI RxD FAULT

DCD RTS TxD1 RxD1 TxD2 RxD2

RS-232

Genibus DI Service

4 digital inputs

Port 1 Port 2 Main Network Connection

Service port for pc

Heating

UPE TPE UPS

Water treatment GENIbus

CU 3 CU 3 CU 3 CU 3 Epump DME Multi-E

Industry

Control 2000

MGE

Epump

CU 3

BMB

BM

BMET

CRN

MG

Water supply

Hydro 2000 SM100 CU 3 CU 3 CU 3 CU 3 CU 3 CU 300 Multi-E

Wastewater

SM 100 Sensors CU 3 SM 100

TM01 1804 1102

Sensors

CR

NK

SP-G

SP

SQE

AP

Sensors

GR5940G100

31

Accessories

Product description The G100 Gateway enables communication of operating data, such as measured values, setpoints, etc., between Grundfos products with GENIbus interface and a main network for control and monitoring.

227 mm

MMS

POWER POWER MNC POWER GENI GENI TxD GENI RxD FAULT

DCD RTS TxD1 RxD1 TxD2 RxD2

Genibus

DI

Service

Common to above applications is that downtime is usually costly, and extra investments are therefore often made to achieve maximum reliability by monitoring selected operating variables. The day-to-day operation, such as starting and stopping of pumps, changing of setpoints, etc., can also be effected from the main system by communication with the G100. In addition, the G100 can be set up to send event-controlled status indications such as alarms via the SMS to mobile phones, and to make automatic alarm call-backs to a central management system. Data logging Besides the possibility of data communication, the G100 also offers logging of up to 350,000 time-stamped data. Subsequently, the logged data can be transmitted to the main system or a PC for further analysis in a spreadsheet or similar program. For the data logging, the "PC Tool G100 Data Log" software tool is used. The tool is part of the PC Tool G100 package, which must be ordered separately. Other features · Four digital inputs. · Stop of all pumps in case of failing communication with the management system (optional). · Access code for modem communication (optional). · Alarm log. Installation Installation of the G100 is effected by the system integrator. The G100 is connected to the GENIbus as well as to the main network. Subsequently, all units on the GENIbus can be controlled from a central management system on the main network. The "G100 Support Files" CD-ROM supplied with the G100 contains examples of programs to be used when the G100 is connected to the various main network systems. Included is also a description of the data points available in Grundfos products with GENIbus interface. The "PC Tool G100" software tool can be used for the G100 installation and use. To be ordered separately.

73 mm

165 mm

Technical data Overview of protocols

Main system INTERBUS-S PROFIBUS-DP Radio Modem PLC GSM mobile phone Software protocol PCP DP Satt Control COMLI/Modbus Satt Control COMLI/Modbus Satt Control COMLI/Modbus SMS, UCP

Other possible connections GENIbus RS-485: Connection of up to 32 units Service port RS-232:

For direct connection to a PC or via radio modem 4 1 x 110-240 V, 50/60 Hz

Digital inputs: Voltage supply:

Ambient temperature: In operation: ­20°C to +60°C Enclosure class: Weight: IP 20 1.8 kg.

Accessories · PC Tool G100 package (to be ordered separately) · G100 Support Files CD-ROM (supplied with product) Product numbers

Product G100 with Interbus-S expansion board* G100 with Profibus-DP expansion board* G100 with Radio/Modem/PLC-expansion board* G100 Basic Version* PC Tool G100 package * CD-ROM with G100 Support Files included. Product number 96411134 96411135 96411136 96411137 96415783

32

TM01 0621 0398

As indicated in the illustration on page 31, the G100 is suitable for use in applications such as water supply, water treatment, wastewater, building automation and industry.

Port 1

Port 2

Main

Network

Connection

Accessories

Cables

Grundfos offers submersible drop cables for all types of applications, i.e. 3-core cables, 4-core cables, single leads. The choice of submersible drop cable depends on the application and type of installation. Max. liquid temperature: +60°C. Tables indicating cable dimensions in borehole The tables indicate the maximum length of drop cables in metres from motor starter to pump (at direct-on-line and star-delta starting) at different cable dimensions. If, for example, the operating current is 10% lower than the full-load current, the cable may be 10% longer than indicated in the table. The calculation of the cable length is based on a maximum voltage drop of 3% of the nominal voltage and a water temperature of maximum 30°C. In order to minimize operating losses, the cable crosssection may be increased compared to what is indicated in the table. This is economical only if: · the borehole provides the necessary space · the operating time of the pump is long or · the operating voltage is below the rated voltage. The table values are calculated on the basis of the following formula: Max. cable length L of a three-phase submersible pump: U U L = ---------------------------------------------------------------------------------------------- = [ m ] I 1.73 100 cos -- + sin X L q where U

U

MMS

Voltage drop: Cross-section: sin:

3% 25 mm2 0.54

400 3 L = ------------------------------------------------------------------------------------------------------------------------------------------------- 0.85 0.02 + 0.54 0.078 × 10 ­ 3 64.0 1.73 100 ----------- 25 L = 150 m

= Rated voltage [V] = Voltage drop [%] = Rated current of the motor [A] = Cross-section of submersible drop cable [mm2] = Inductive resistance: 0.078 x 10-3 [/m]

I q XL

cos = Power factor sin

= 1 ­ cos2 = Specific resistance: 0.02 [ mm2/m]

Example: Motor size: 30 kW, MMS 8000 Rated current: 64.0 A Rated voltage: 3 x 400 V, 50 Hz Starting method: Direct-on-line Power factor: cos = 0.85

33

Accessories

Cable dimensions for MMS motors at 3 x 400 V, 50 Hz, direct-on-line starting Voltage drop: 1%

Motor [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 92 MMS 8000 110 132 147 170 190 MMS 12000 147 170 190 220 250 In [A] 9.85 14.0 18.4 22.4 26.0 30.0 34.0 40.5 47.5 56.0 64.0 85.5 48.0 56.5 64.0 78.5 96.5 114 132 152 186 224 156 194 228 270 315 365 425 305 345 390 445 505 Cos 100% 0.81 0.81 0.80 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.79 0.84 0.85 0.85 0.85 0.82 0.85 0.83 0.86 0.86 0.87 0.84 0.82 0.84 0.84 0.81 0.81 0.79 0.83 0.85 0.84 0.85 0.85 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 430 49 57 50 52 43 28 23 44 37 33 27 Cross-section [mm2] 1.5 22 15 12 2.5 36 25 19 16 4 57 40 31 25 21 19 6 85 60 46 38 32 28 24 20 10 141 99 76 62 53 46 40 33 29 24 16 222 156 120 97 83 72 63 53 45 37 33 25 338 238 183 149 127 110 96 81 69 57 51 40 67 57 50 41 34 35 461 324 249 203 173 150 131 110 94 78 69 54 92 78 68 56 47 38 50 634 446 342 279 238 207 181 152 129 108 95 74 127 107 95 77 64 53 47 40 595 456 372 318 276 242 203 173 145 128 99 170 144 127 104 86 71 62 53 43 763 583 477 409 354 311 261 223 187 165 126 220 186 164 134 110 92 80 69 56 47 68 55 46 913 697 570 490 425 374 314 267 226 198 150 264 224 197 161 132 111 96 83 68 56 81 66 56 47 818 671 577 500 441 370 315 267 234 176 312 265 234 191 155 131 113 98 80 67 96 77 66 55 48 942 773 666 578 510 428 365 310 271 203 361 307 271 221 180 152 131 114 94 78 111 89 76 64 55 910 786 681 603 506 432 368 321 238 428 365 322 263 212 181 155 136 111 93 132 105 90 76 65 56 48 67 60 53 70 95 120 150 185 240

MMS

300

894 775 687 577 492 422 367 269 489 418 369 301 241 207 177 156 128 107 151 120 103 87 74 63 54 77 68 60 53 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

34

Accessories

Cable dimensions for MMS motors at 3 x 400 V, 50 Hz, direct-on-line starting Voltage drop: 3%

Motor [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 MMS 12000 147 170 190 220 250 In [A] 9.85 14.0 18.4 22.4 26.0 30.0 34.0 40.5 47.5 56.0 64.0 85.5 48.0 56.5 64.0 78.5 96.5 114 132 152 186 224 156 194 228 270 315 365 425 305 345 390 445 505 Cos 100% 0.81 0.81 0.80 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.79 0.84 0.85 0.85 0.85 0.82 0.85 0.83 0.86 0.86 0.87 0.84 0.82 0.84 0.84 0.81 0.81 0.79 0.83 0.85 0.84 0.85 0.85 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 430 147 170 151 157 128 84 70 132 111 98 80 Cross-section [mm2] 1.5 65 46 35 2.5 108 76 58 47 4 172 121 93 76 64 56 6 256 180 139 113 96 83 73 61 10 422 297 229 186 158 137 120 100 86 71 16 665 468 360 292 249 216 189 158 135 112 99 713 548 446 380 330 288 242 206 172 152 119 202 170 150 122 102 973 747 608 519 450 394 330 282 235 207 162 276 233 205 168 140 115 837 715 620 543 456 388 325 286 223 382 322 284 232 193 159 140 119 955 828 726 610 520 436 383 296 511 432 381 311 257 214 187 160 130 934 784 668 562 494 378 659 557 492 401 330 276 240 206 169 140 203 164 139 941 802 677 594 451 792 671 592 483 396 333 289 249 203 169 244 197 167 141 946 801 701 529 935 794 701 572 466 394 340 295 241 200 288 232 197 166 143 922 814 664 539 457 394 343 281 233 334 268 228 193 165 967 789 635 543 466 409 334 279 395 316 271 228 194 168 143 202 179 158 930 813 608 964 713 25 35 50 70 95 120 150 185 240

MMS

300

806

903 723 622 531 469 383 321 452 360 309 261 221 190 162 230 205 181 159 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

35

Accessories

Cable dimensions for MMS motors at 3 x 400 V, 50 Hz, star-delta-starting Voltage drop 1%

Motor [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 MMS 12000 147 170 190 220 250 In [A] 9.85 14 18.4 22.4 26 30 34 40.5 47.5 56 64 85.5 48 56.5 64 78.5 96.5 114 132 152 186 224 156 194 228 270 315 365 425 305 345 390 445 505 Cos 100% 0.81 0.81 0.80 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.79 0.84 0.85 0.85 0.85 0.82 0.85 0.83 0.86 0.86 0.87 0.84 0.82 0.84 0.84 0.81 0.81 0.79 0.83 0.85 0.84 0.85 0.85 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 430 85 98 87 91 74 48 41 76 64 57 46 Cross-section [mm2] 1.5 37 26 20 2.5 62 44 34 27 4 99 70 54 44 37 32 6 148 104 80 65 55 48 42 35 10 244 172 132 107 91 79 69 58 49 41 16 384 270 208 169 144 125 109 91 78 65 57 25 585 412 317 257 220 190 166 140 119 99 87 69 117 98 87 71 59 35 798 562 431 351 300 260 227 191 163 136 120 94 160 134 119 97 81 67 773 593 483 413 358 313 263 224 187 165 129 220 186 164 134 111 92 81 69 789 644 552 478 419 352 300 252 221 171 295 249 220 179 149 124 108 92 75 826 708 614 539 453 386 325 285 218 380 322 284 232 191 159 139 119 97 81 117 95 80 988 849 735 647 543 463 391 343 261 457 387 342 279 229 192 167 144 117 97 141 114 96 81 999 866 763 641 546 463 405 305 540 458 405 330 269 227 197 170 139 116 166 134 114 96 83 883 741 632 537 469 351 626 532 470 383 311 264 227 198 162 135 193 155 132 111 95 50 70 95 120 150 185 240

MMS

300

877 747 638 556 412 742 633 558 455 367 314 269 236 193 161 228 183 156 132 112 97 83 116 104 91

999 852 731 636 466 848 724 639 521 417 359 307 271 221 185 261 208 178 151 127 110 94 133 119 104 92 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

36

Accessories

Cable dimensions for MMS motors at 3 x 400 V, 50 Hz, star-delta starting Voltage drop 3%

Motor [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 MMS 12000 147 170 190 220 250 In [A] 9.85 14 18.4 22.4 26 30 34 40.5 47.5 56 64 85.5 48 56.5 64 78.5 96.5 114 132 152 186 224 156 194 228 270 315 365 425 305 345 390 445 505 Cos 100% 0.81 0.81 0.80 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.84 0.79 0.84 0.85 0.85 0.85 0.82 0.85 0.83 0.86 0.86 0.87 0.84 0.82 0.84 0.84 0.81 0.81 0.79 0.83 0.85 0.84 0.85 0.85 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 430 255 295 262 272 222 145 122 229 192 170 139 Cross-section [mm2] 1.5 112 79 61 2.5 187 131 101 82 4 297 209 161 131 111 97 6 444 312 240 195 166 144 126 105 10 731 515 396 322 274 237 207 174 148 123 810 623 506 431 374 326 274 234 194 172 950 772 659 571 499 419 357 297 262 206 350 295 260 212 177 899 779 682 572 488 407 359 281 479 403 356 290 242 200 940 789 673 562 496 386 661 557 492 401 334 276 242 206 900 755 664 513 886 748 660 538 446 371 324 277 226 965 852 695 572 478 417 357 292 242 351 285 240 836 686 576 500 431 352 292 422 341 289 244 990 808 682 590 511 418 347 498 402 341 288 248 933 792 682 595 486 404 578 464 395 334 286 974 856 655 782 916 16 25 35 50 70 95 120 150 185 240

MMS

300

941 807 708 579 483 685 548 469 396 336 290 248 349 311 274 920 813 664 555 782 623 535 452 382 330 281 398 356 313 276 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

37

Accessories

Cable dimensions for MMS motors at 3 x 460 V, 60 Hz, direct-on-line starting Voltage drop 1% Cos 100% 0.80 0.80 0.79 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.85 0.79 0.84 0.86 0.85 0.85 0.85 0.86 0.86 0.86 0.87 0.87 0.84 0.83 0.84 0.85 0.82 0.82 0.79 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 61 50 32 27 50 42 38 31 Cross-section [mm2] 1.5 25 18 14 2.5 42 30 23 18 4 67 48 37 29 25 22 19 6 100 71 55 44 37 32 28 24 10 165 117 91 72 62 53 47 40 34 28 16 260 184 143 114 97 84 73 63 53 44 39 25 397 280 217 174 149 128 112 96 82 68 59 48 77 65 58 47 40 35 541 382 296 237 203 175 153 132 112 93 81 65 105 88 79 65 55 45 50 743 525 406 326 279 242 211 181 154 128 112 90 145 122 109 89 75 62 55 46 70 989 699 539 436 373 323 282 243 206 172 150 119 194 165 146 120 101 83 74 62 50 894 689 558 479 414 363 312 265 221 193 152 250 213 189 155 130 107 95 80 65 54 79 64 54 822 668 574 497 436 374 318 267 233 182 300 257 227 186 157 129 115 97 79 66 95 77 65 55 963 785 676 585 514 442 374 316 275 213 355 304 269 220 186 154 136 115 93 78 112 91 77 65 57 906 781 675 595 511 433 366 320 245 411 354 312 256 216 179 159 133 109 91 130 105 89 75 65 56 95 120 150 185 240

MMS

Motor

[kW] 3.7 5.5 7.5 9.2 11 13 15 18.5 22 26 30 37 22 26 30 37 45 55 63 75 92 110 75 92 110 132 147 170 190

In [A] 9.75 13.8 18.0 22.0 25.5 29.5 33.5 39.0 46.0 54.5 62.5 81.5 48.5 56.5 64.0 78.0 92.5 112 126 150 184 220 154 190 224 265 305 355 405

300

MMS 6000

922 797 704 604 512 435 380 287 488 422 371 304 257 213 189 159 130 109 154 124 106 90 77 66 58 430 907 802 689 584 498 435 324 557 484 424 348 294 244 217 182 150 125 175 141 121 103 88 75 65 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

38

MMS 10000

MMS 8000

Accessories

Cable dimensions for MMS motors at 3 x 460 V, 60 Hz, direct-on-line starting Voltage drop 3%

Motor [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 In [A] 9.75 13.8 18.0 22.0 25.5 29.5 33.5 39.0 46.0 54.5 62.5 81.5 48.5 56.5 64.0 78.0 92.5 112 126 150 184 220 154 190 224 265 305 355 405 Cos 100% 0.80 0.80 0.79 0.81 0.82 0.82 0.83 0.83 0.83 0.85 0.85 0.79 0.84 0.86 0.85 0.85 0.85 0.86 0.86 0.86 0.87 0.87 0.84 0.83 0.84 0.85 0.82 0.82 0.79 18.5 25 34 43 60 80 101 126 153 196 238 276 319 364 183 149 95 80 150 126 113 93 Cross-section [mm2] 1.5 76 54 42 2.5 127 90 70 55 4 202 143 111 88 75 65 57 6 301 213 165 132 112 97 85 73 10 496 351 272 217 185 160 140 120 102 84 16 781 552 428 342 292 252 220 189 160 132 116 841 651 522 446 385 336 289 245 203 177 144 230 194 173 142 119 887 712 609 526 459 395 335 278 242 196 315 265 236 194 164 134 979 838 725 633 544 461 384 335 269 434 367 327 268 226 185 165 138 968 847 728 617 515 449 357 582 494 438 360 303 249 221 186 151 936 794 664 579 457 750 639 566 464 391 322 286 241 195 163 236 192 162 953 800 698 545 901 770 681 559 471 388 345 290 236 197 284 231 195 165 913 806 661 558 461 409 344 280 234 335 272 230 195 170 936 768 648 536 476 400 327 273 389 315 267 226 196 168 947 826 638 959 734 25 35 50 70 95 120 150 185 240

MMS

300

860

973

913 770 638 567 477 390 326 461 372 317 269 231 199 173 430 881 732 651 547 449 375 526 424 362 308 263 226 196 497

Max. current for cable [A]*

* At particularly favourable heat dissipation conditions. Maximum cable length in metres from motor starter to pump.

39

Accessories

Sizing of cable

Calculation of the cross-section of the cable Formula designations U = Rated voltage [V]

U

MMS

Calculation of power loss Choice A: p A = 3 L I --------------------------q 3 200 0.02 96.5 2 p A = ---------------------------------------------------150 p A = 745 W Choice B:

2

= Voltage drop [%] = Rated current of the motor [A] = Cross-section [mm2] = Inductive resistance 0.078 x 10-3 [/m] = Power factor = 1­ cos2

I q XL cos sin L

p

= Length of cable [m] = Power loss [W] = 1/ Materials of cable: Cubber: = 52 m/ x mm2 Aluminium: = 35 m/ x mm2 3 200 0.02 96.5 2 p B = ---------------------------------------------------185 p B = 604 W Savings Operating hours/year: h = 4000. Annual saving (A):

A = ( p ­ p ) h = ( 745 W ­ 604 W ) 4000 = 564000Wh = 564kWh A B

For calculation of the cross-section of the submersible drop cable, use the following formula: DOL I 1.73 100 L cos q = -----------------------------------------------------------------------------------------------U U ­ ( I 1.73 100 L X sin ) L Star-delta I 100 L cos q = -----------------------------------------------------------------------------------------------U U ­ ( I 1.73 100 L X sin ) L The values of the rated current (I) and the power factor (cos) can be read in the tables on pages 14-19. Calculation of the power loss For calculation of the power loss in the submersible drop cable, use the following formula: 3LI p = --------------------------q Example: Motor size: Rated current: Voltage: Starting method: Required cable length: Water temperature: Cable selection: Choice A: Choice B:

2

By choosing the cable size 3 x 185 mm2 instead of 3 x 150 mm2, an annual saving of 564 kWh is achieved. Operating time: 10 years Saving after 10 years (A10): A 10 = A 10 = 564 10 = 5640 kWh

The saving in amount must be calculated in the local currency.

45 kW, MMS 8000 In = 96.5 A 3 x 400 V, 50 Hz Direct-on-line 200 m 25°C

3 x 150 mm2 3 x 185 mm2

40

Accessories

Cable termination kit, type KM

Version Description Motor cable Flat cable For watertight shrink-joining of motor cable and submersible drop cable. Enables the joining of: · cables of equal size · cables of different size · a cable lead and a single-lead

TM00 7885 2296

MMS

[mm2] 6 - 10 10 - 16 16 - 25 1.5 - 6.0 10 - 25 1.5 - 4.0 6 - 16

Number of leads 4 3 3 4 3 3 4 4

Product no.

00116252 00116255 00116253 00116254 00116257 00116258

Flat cable 3 single leads 3 single leads 4 single leads 4 single leads

The joint is ready for use after a few minutes and requires no long hardening time as opposed to resin joints. The joint cannot be separated.

Single lead *

35 - 120

1

00116256

* Used for the repair or joining of single leads. When ordering kits, please state the number required.

Cable termination kit

Description For watertight joining of motor cable and submersible drop cable. For 4" motors and drop cables up to 4 x 6 mm2 For 6" motors and drop cables up to 4 x 10 mm2

TM00 7884 2296

Version Type M0 M1 M2 M3 M4 M5 M6 Diameter of joint [mm] ø40 ø46 ø52 ø77 ø97 ø110 ø144 For outer cable diameter [mm] app. 6-15 app. 9-23 app. 17-31 app. 26-44 app. 29-55 app. 40-62 app. 50-80 Product no.

00ID8903 00ID8904 00ID8905 00ID8906 91070700 96496918 96496919

For 6" motors and drop cables up to 4 x 16 mm2 For 8" and 10" motors and drop cables up to 4 x 35 mm2 For 8" and 10" motors and drop cables up to 4 x 70 mm2 For 8", 10" and 12" motors and drop cables up to 4-70 mm 2 For 8", 10" and 12" motors and drop cables up to 4-70 mm 2

Submersible drop cable

Description Number of leads and nominal cross section [mm2] 1 x 16 1 x 25 1 x 35 1 x 50 1 x 70 1 x 95 1 x 120 1 x 150 1 x 185 3 x 1.5 3 x 2.5 3 x 4.0 3 x 6.0 3 x 10 3 x 16 3 x 25 4G1.5 4G2.5 4G4.0 4G6.0 4G10 4G16 4G25 4G35 4G50 4G70 Outer diameter Min./Max. [mm2] 11.0 / 14.5 12.5 / 16.5 14.0 / 18.5 16.5 / 21.0 18.5 / 23.5 21.0 / 26.5 23.5 / 28.5 26.0 / 31.5 27.5 / 34.5 9.5 / 12.5 11.5 / 14.5 13.0 / 16.0 14.5 / 20.0 20. 0 / 25.5 22.5 / 29.5 26.5 / 34.0 10.5 / 13.5 12.5 / 15.5 14.5 / 18.0 16.5 / 22.0 22.5 / 24.5 26.5 / 28.5 32.0 / 34.0 33.0 / 42.5 38.0 / 48.5 43.0 / 54.5

Weight [kg/m]

Product no.

Suitable for · continuous application in groundwater and potable water (approved for potable applications) · connection of electrical equipment such as submersible motors · installation depths up to 500 metres and average loads. Insulation and sheath are made of special EPRbased elastomer materials adapted to applications in water. Maximum permissible water temperature: 60°C. Maximum permissible lead service temperature: 90°C. Further cable sizes are available on request.

TM00 7882 2296

0.290 0.410 0.560 0.740 1.000 1.300 1.650 2.000 2.500 0.150 0.220 0.340 0.480 0.750 1.100 1.450 0.190 0.280 0.390 0.520 0.950 1.400 1.950 2.700 3.600 4.900

ID4071 ID4072 ID4073 ID4074 ID4075 ID4076 ID4077 ID4078 ID4079 ID4056 ID4057 ID4058 ID4059 ID4060 ID4061 ID4062 ID4063 ID4064 ID4065 ID4066 ID4067 ID4068 ID4069 ID8917 91070691 91070692

41

Accessories

Pt100

The Pt100 sensor allows · continuous monitoring of the motor temperature · protection against too high motor temperature. Protecting the motor against too high motor temperature is the simplest and cheapest way of avoiding that motor lifetime is reduced. Pt100 ensures that operating conditions are not exceeded and indicates when it is time for service of the motor. Monitoring and protection by means of Pt100 require the following parts: · Pt100 sensor with cable · Relay type EDM 35 or PR2202. The EDM 35 relay is fitted with a Pt100 module. For both relays the following temperature limits are pre-set on delivery: · 60°C warning limit · 75°C stop limit.

Enclosure class Ambient temp. Relative humidity Voltage variation Frequency Approvals Mark IP 65 0°C to +50°C 90% ­10/+10% of nominal voltage 50/60 Hz UL, CSA, SEV CE EDM 35 IP 50

MMS

Technical data

Relay type PR 2202 ­20°C to +60°C 90% 24 VDC ­20/+20% of nominal voltage

Example: Pt100 for Grundfos MMS submersible rewindable motors

Product range Pt100 sensor including EDM 35 relay and cable

Product number Voltage Cable length MS 6000 20 m 40 m 60 m 80 m 100 m 96420869 96420870 96420871 96420872 96420873 24 V, 50/60 Hz MMS 6000 MMS 8000 96494566 96494567 96494568 96494569 96494590 MMS 10000 MMS 12000 96437277 96437278 96437279 96437280 96437281 MS 6000 96420864 96420865 96420866 96420867 96420868 115 V, 50/60 Hz MMS 6000 MMS 8000 96494591 96494592 96494593 96494594 96494595 MMS 10000 MMS 12000 96437282 96437283 96437284 96437285 96437286 MS 6000 96408953 96408681 96408954 96408955 96408956 230 V, 50/60 Hz MMS 6000 MMS 8000 96494596 96494597 96494598 96494599 96494610 MMS 10000 MMS 12000 96437287 96437288 96437289 96437290 96437291

EDM 35 relay

Voltage 24 VAC, 50/60 Hz 115 VAC, 50/60 Hz 230 VAC, 50/60 Hz Product number 96420719 96420718 96408688

PR 2202 relay

Voltage 24 VAC, 50/60 Hz Product number 96439805

Pt100 sensor including cable

Product number Cable length MS 6000 and MMS 6000, MMS 8000 96408957 96408684 96408958 96408959 96408960 MMS 10000, MMS 12000 96437784* 96437785* 96437786* 96437787* 96437788*

20 m 40 m 60 m 80 m 100 m * Incl. fitting.

42

TM01 8141 5099

Order data

3 x 220 V, 60 Hz

Product number Motor power EN-JL1040 [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 MMS 8000 30 37 45 55 63 75 MMS 10000 75 92 110 132 [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 100 125 150 180 DOL 96457631 96457632 96441900 96441901 96441902 96441903 96441904 96441905 96439622 96439623 96439624 96457643 96457644 96457645 96442309 96439626 96439627 96439628 96439629 96457647 96457648 96439638 SD 96446025 96457628 96457629 96457630 96442310 96442313 96442315 96442317 96442319 DOL 96457658 96457659 96457660 96457661 96457662 96457663 96457664 96457665 96457666 96457667 96457668 96457670 96457671 96457672 96457673 96457674 96457675 96457676 96457677 96457679 96457680 96457682 PVC windings Ceramic/carbon DIN/EN 1.4401

3 x 220 V, 60 Hz

SD 96457649 96457650 96457651 96457652 96457653 96457654 96457655 96457656 96457657 -

43

Order data

3 x 220-230 V, 50 Hz

Product number Motor power EN-JL1040 [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 MMS 8000 30 37 45 55 63 MMS 10000 75 92 110 [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 DOL 96432245 96432246 96432247 96432248 96432249 96432250 96432251 96432252 96432253 96432254 96432255 96432257 96432258 96432259 96432260 96432261 96432262 96432263 96432291 96432292 SD 96432267 96432268 96432269 96432270 96432271 96432272 96432273 96432274 96432275 96432276 96432277 96432278 96432279 96432280 96432281 96432282 96432283 96432284 96432285 96432294 96432295 DOL 96444329 96444330 96444332 96444333 96444334 96444335 96444336 96444337 96444338 96444339 96444340 96444342 96444343 96444344 96444345 96444346 96444347 96444348 96444350 96444351 PVC windings Ceramic/carbon

3 x 220-230 V, 50 Hz

DIN/EN 1.4401 SD 96444352 96444353 96444354 96444355 96444356 96444357 96444358 96444359 96444360 96444361 96444363 96444364 96444365 96444366 96444367 96444368 96444369 96444370 96444372 96444514 96444515

44

Order data

3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz

3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz

Product number Motor power EN-JL1040 [kW] [hp] DOL SD PVC windings Ceramic/carbon DIN/EN 1.4401 DOL SD DOL 3 x 380-415 V, 50 Hz 3 x 460 V, 60 Hz 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 147 170 190 220 250 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 96430655 96430656 96430657 96430658 96430659 96430660 96430661 96430662 96430663 96430664 96430665 96430666 96430667 96430668 96430669 96430670 96430671 96430672 96430673 96430674 96430675 96430676 96430678 96430679 96430680 96430681 96438116 96438118 96430682 96430683 96430684 96430685 96430686 96432081 96432082 96432083 96432084 96432085 96432086 96432087 96432088 96432089 96432090 96432091 96432092 96432093 96432094 96432095 96432096 96432097 96432098 96432099 96432100 96432101 96432103 96432104 96432105 96432106 96438117 96438119 96432107 96432108 96432109 96432110 96432111 96444516 96444517 96444518 96444519 96444520 96444521 96444522 96444523 96444524 96444525 96444526 96444527 96444528 96444529 96444530 96444531 96444532 96444533 96444534 96444535 96444536 96444537 96444539 96444540 96444541 96444542 96444543 96444544 96444628 96444629 96444630 96444631 96444632 96444546 96444547 96444548 96444549 96444550 96444551 96444552 96444553 96444554 96444555 96444556 96444557 96444558 96444559 96444560 96444561 96444562 96444563 96444564 96444565 96444566 96444568 96444569 96444570 96444571 96444572 96444573 96444633 96444634 96444635 96444636 96444637 96477813 96477814 96477815 96477816 96477817 96477818 96477819 96477850 96477851 96477852 96477853 96457282 96095117 96095118 96095119 96095120 96457284 96457285 96457286 96457287 96457288 96457289 96513080 96494090 96457290 96457291 96457292 96463669 96540687 96493224 96457293 96540350 96540351 96094978 96094979 96094980 96094981 96094982 96094983 96094984 96094985 96094986 96094987 96457294 96095127 96095128 96095129 96095130 96457295 96457296 96457297 96457298 96457299 96457300 96540680 96494091 96457301 96457302 96457303 96540308 96540688 96481314 96457304 96540354 96540355 96095037 96095038 96095039 96095040 96095041 96095042 96095043 96095044 96095045 96095046 96484742 96457305 96095177 96095178 96095179 96486180 96457306 96457307 96457308 96457309 96457310 96457311 96540682 96540683 96457312 96457313 96457314 96540314 96540689 96540690 96457315 96540359 96540360 96095050 96095051 96095052 96095053 96095054 96095055 96095056 96095057 96095058 96095059 96457316 96095187 96095188 96095189 96095190 96457317 96457318 96457319 96457320 96457321 96457322 96540685 96540686 96457323 96457324 96457325 96540320 96540691 96540692 96457326 96540364 96540365 EN-JL1040 SD SiC/SiC DIN/EN 1.4401 DOL SD

3 x 380-415 V, 50 Hz MMS 12000

45

Order data

3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz

3 x 380-415 V, 50 Hz and 3 x 460 V, 60 Hz

Product number Motor power EN-JL1040 [kW] [hp] DOL SD PE/PA windings Ceramic/carbon DIN/EN 1.4401 DOL SD DOL 3 x 380-415 V, 50 Hz 3 x 460 V, 60 Hz 7.5 9.2 11 MMS 6000 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 147 170 190 220 250 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 96094991 96094992 96470733 96470734 96470735 96470736 96464411 96221394 96470737 96470738 96095137 96095138 96095139 96095140 96470739 96470780 96473399 96221395 96473490 96466552 96473394 96526004 96473395 96473396 96438116 96438118 96540322 96540323 96465240 96430685 96430686 96095005 96095006 96095007 96095008 96095009 96095010 96095011 96095012 96095147 96095148 96095149 96095150 96095151 96095152 96095153 96095154 96095155 96095156 96540275 96540276 96540277 96540278 96438117 96438119 96540326 96540327 96540328 96432110 96432111 96539856 96539858 96539859 96539870 96539871 96526826 96539872 96511389 96539873 96496461 96529936 96529937 96529938 96529939 96530000 96530002 96530003 96530004 96530005 96530006 96540290 96540291 96540292 96540293 96444543 96444544 96540329 96540330 96540331 96444631 96444632 96539876 96539878 96539879 96539880 96539881 96539882 96539883 96539884 96530008 96530009 96530011 96530012 96530013 96530014 96530016 96530017 96530018 96530019 96540295 96540296 96540297 96540298 96444572 96444573 96540332 96540333 96540334 96444636 96444637 96540057 96540058 96540059 96540110 96540111 96497415 96540113 96497110 96509553 96476890 96530168 96530169 96530180 96530182 96476891 96476892 96530184 96476893 96476894 96511375 96540300 96540301 96521619 96540302 96457292 96463669 96540337 96540338 96540339 96540350 96540351 96540120 96540121 96540122 96540123 96540124 96540125 96540126 96540127 96530185 96530187 96530189 96530191 96530192 96530193 96530195 96489499 96489347 96530196 96540304 96540305 96540306 96540307 96457303 96540308 96540352 96540366 96540353 96540354 96540355 96540170 96540171 96540172 96540173 96540174 96540175 96540176 96540177 96540178 96540179 96530081 96530083 96530084 96530085 96481247 96530087 96530088 96530089 96530100 96496894 96540310 96540311 96540312 96540313 96457314 96540314 96540356 96540357 96540358 96540359 96540360 96540192 96540193 96540194 96540195 96540196 96540197 96540198 96540199 96530102 96530103 96530104 96530105 96530106 96530107 96530108 96530109 96530110 96530111 96540316 96540317 96540318 96540319 96457325 96540320 96540361 96540362 96540363 96540364 96540365 EN-JL1040 SD SiC/SiC DIN/EN 1.4401 DOL SD

3 x 380-415 V, 50 Hz MMS 12000

46

Order data

3 x 500 V, 50 Hz and 3 x 575 V, 60 Hz

Product number Motor power EN-JL1040 [kW] 7.5 9.2 11 MMS 6000 13 15 18.5 22 26 30 37 [hp] 10 12.5 15 17.5 20 25 30 35 40 50 DOL 96437548 96435750 96437552 96437554 96437555 96437556 96437561 96437562 96437563 96437564 SD 3 x 500 V, 60 Hz 96437567 96437568 96437569 96437570 96437571 96437572 96437573 96437574 3 x 500 V, 50 Hz 3 x 575 V, 60 Hz 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 147 170 190 220 250 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 200 230 260 300 340 96432296 96432297 96432298 96432299 96432300 96432301 96432302 96432303 96432304 96432305 96432307 96432308 96432309 96432310 96438170 96438171 96432311 96432312 96432313 96432314 96432315 96432316 96432317 96432318 96432319 96432320 96432321 96432322 96432323 96432324 96432325 96432327 96432328 96432329 96432330 96438172 96438173 3 x 500 V, 50 Hz MMS 12000 96432331 96432332 96432333 96432334 96432335 PVC windings Ceramic/carbon

3 x 500 V, 50 Hz and 3 x 575 V, 60 Hz

DIN/EN 1.4401 DOL 96444574 96444575 96444576 96444577 96444578 96444579 96444580 96444581 96444582 96444583 SD 96444603 96444604 96444605 96444606 96444607 96444608 96444609 96444610

96444584 96444585 96444586 96444587 96444588 96444589 96444590 96444591 96444592 96444593 96444595 96444596 96444597 96444598 96444599 96444600 96444638 96444639 96444640 96444641 96444642

96444611 96444612 96444613 96444614 96444615 96444616 96444617 96444618 96444619 96444620 96444622 96444623 96444624 96444625 96444626 96444627 96444643 96444644 96444645 96444646 96444647

47

Order data

3 x 380 V, 60 Hz, PVC windings

Product number Motor power EN-JL1040 [kW] 3.7 5.5 7.5 9.2 MMS 6000 11 13 15 18.5 22 26 30 37 22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190 [hp] 5.0 7.5 10 12.5 15 17.5 20 25 30 35 40 50 30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260 DOL 96438729 96438730 96438731 96438732 96438733 96438734 96438735 96438736 96438737 96438738 96438739 96438741 96453623 96453624 96453625 96442311 96439632 96439633 96439634 96439635 96439636 96439637 96453627 96453628 96439639 96439640 96439641 96453629 SD 96446026 96453630 96453631 96453632 96442312 96442314 96442316 96442318 96442320 96442322 96453633 96453635 96453636 96453637 96453638 96453639 96453640 DOL PVC windings Ceramic/carbon

3 x 380 V, 60 Hz, PVC windings

DIN/EN 1.4401 SD 96457713 96457714 96457715 96457716 96457717 96457718 96457719 96457720 96457721 96457722 96457723 96457725 96457726 96457727 96457728 96457729 96457730 96457683 96457684 96457685 96457686 96457687 96457688 96457689 96457690 96457691 96457692 96457693 96457694 96457695 96457696 96457697 96457699 96457700 96457701 96457702 96457703 96457704 96457705 96457707 96457708 96457709 96457710 96457711 96457712

48

Order data

3 x 380 V, 60 Hz, PE/PA windings

Product number Motor power EN-JL1040 [kW] MMS 6000 [hp] DOL SD PE/PA windings Ceramic/carbon DIN/EN 1.4401 DOL SD DOL

3 x 380 V, 60 Hz, PE/PA windings

SiC/SiC EN-JL1040 SD DIN/EN 1.4401 DOL SD

37

50

96507886

96507887

96540392

96510921

96540395

96483156

96540397

96540399

22 26 30 MMS 8000 37 45 55 63 75 92 110 75 MMS 10000 92 110 132 147 170 190

30 35 40 50 60 75 85 100 125 150 100 125 150 180 200 230 260

96540463 96540464 96540465 96540467 96507888 96507889 96540468 96540469 96507900 96500150 96540571 96540570 96509377 96507901 96439641 96453629

96540482 96540483 96540484 96540485 96509371 96509372 96540486 96540487 96540488 96540490 96509374 96509375 96540579 96507902 96453639 96453640

96540491 96540492 96540493 96540494 96540495 96540496 96540497 96540498 96540499 96540500 96540585 96540586 96540587 96540589 96457711 96457712

96540501 96540502 96540503 96540504 96540505 96540506 96540507 96540508 96540509 96540510 96540602 96540603 96540604 96540606 96457729 96457730

96540511 96540512 96540513 96540514 96540515 96540517 96540518 96540519 96540530 96540531 96540609 96540610 96511772 96540611 96505267 96540612

96540532 96540533 96540534 96540535 96483158 96483160 96483161 96483162 96483163 96540536 96540614 96540616 96540617 96540618 96485244 96540619

96540537 96540538 96540539 96540540 96491000 96540541 96540542 96540543 96540544 96540545 96540622 96540623 96111546 96540624 96540625 96540626

96540546 96540547 96540548 96540549 96540550 96540551 96540556 96540557 96540558 96540559 96540671 96540672 96540673 96540674 96540675 96540676

49

Further product documentation

In addition to this printed data booklet, Grundfos offers the following sources of product documentation. · WinCAPS · WebCAPS.

MMS

WinCAPS

WinCAPS is a Windows-based Computer Aided Product Selection program containing information on more than 90,000 Grundfos products.

cd-wincaps

Available on CD-ROM in more than 15 languages, WinCAPS offers · detailed technical information · selection of the optimum pump solution · dimensional drawings of each pump · detailed service documentation · installation and operating instructions · wiring diagrams of each pump.

Fig. 1 WinCAPS CD-ROM

Click Catalogue and select a product from the extensive product catalogue.

Click Sizing and select the most suitable pump for your application.

Fig. 2 WinCAPS

50

WinCAPS

Further product documentation

WebCAPS

WebCAPS is a Web-based Compute Aided Product Selection program and a web-version of WinCAPS. WebCAPS is accessible on Grundfos' homepage,

www.grundfos.com, and offers

MMS

· detailed technical information · dimensional drawings of each pump · wiring diagrams of each pump.

Click Catalogue and select a product from the extensive product catalogue.

Click Literature to select and download Grundfos documentation by browsing the product ranges or performing a specific search. Literature includes: ­ data booklets ­ installation and operating instructions ­ service etc.

Click Service to find information on service kits and spare parts.

Click Replacement and select the right replacement pump based on the current installation. Click CAD drawings to select and download CAD drawings in: ­.stp ­.dxf ­.dwg

Click Search and select a product from the extensive product catalogue.

Being a registered user click Log in to: ­ save your settings ­ define and save your own units ­ save personalised information. Click Settings and select your preferred options.

Click Sizing and select the most suitable pump for your application.

Fig. 3 WebCAPS

WebCAPS

51

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence

V7156900 0905

Repl. V7156900 0205

GB

Subject to alterations.

GRUNDFOS A/S . DK-8850 Bjerringbro . Denmark Telephone: +45 87 50 14 00 www.grundfos.com

Information