Keyscan Access Control

At Keyscan, the commitment is to quality and customer satisfaction. Keyscan has a team of professionals dedicated to designing and building the best in access control systems. Systems that address today's real-world security challenges. And with Keyscan you get much more... · personal touch service · world-class technical support · dedication to innovation & improvements · rigorous QA product testing Reliability, scalability, and flexibility are the hallmarks of Keyscan access control systems, and with the ground breaking VantageTM software... you truly have total control.

Keyscan Access Control Systems Deliver.....

· flexible communication options - LAN/WAN (TCP/IP) - modem - serial (RS232, RS485 & USB) · unlimited sites with 32,000 cardholders per site · emergency lock down provisions · manual security override to lock/unlock individual doors · momentary & timed unlock control · email alarm messaging to cell phones, pagers, Blackberrys · facility mapping capability for quick alarm response · scheduled auto database backups · multiple card format support · 255 site codes for card uniqueness · cardholder database import/export provision · scheduled cardholder import/export with other corporate systems ­ e.g. Human Resources database · "first person in" door lock safeguard · handicap door monitor settings · selectable operator permissions · scheduled and emailed reports

Keyscan VantageTM ­ Uncompromising Access Control

Vantage

· fast operator access to primary functions · operator actions/tasks logged in audit trail

Organized...Ease of Use....Logical.

TM

VantageTM delivers an easy to navigate interface that's intuitive for both the seasoned installer and the novice user. Includes 4 concurrent Client licenses for greater system administration and control.

· adjustable screen dynamics - Online Transactions or Alarm View · software access protected by password login

All supported with full context-sensitive, on-line help.

Cardholder Record

· 5 group access levels for enhanced flexibility · card scan enrollment feature · latest "site transactions" window · temporary card countdown/date function · "one-click" handicap setting

Group Access Levels

· separate door and elevator access levels · formatted in spreadsheet layout · presents all access details on 1 screen · designed for expedient setup

Disaster Recovery

· insurance against database corruption/hard drive failure · restores system operation in minutes · downloads vital data from each panel · intuitive interface for rapid recovery

Management Control Across the Enterprise Global Anti-passback*

· true global anti-passback enforcement · selectable anti-passback modes - Hard Anti-passback - Hard Anti-passback with communication failure - Soft Anti-passback · anti-passback group exemptions · panels maintain IN/OUT status

* requires GCM or ECM at each panel.

Present 3

· "on-the-fly" reader initiated card control · toggles door locks for temporary or unscheduled access · initiates emergency lockdown · toggles time zones to arm/disarm security devices · flashing reader LED indicates "in-effect" status

IOCB1616**

· integrates additional inputs and outputs for external devices · supports up to 64 inputs and 64 outputs per control unit · uses logical "and" "or" conditions to assign multiple inputs to an output · has 7 operating modes · auto schedule activation/de-activation of inputs or outputs

** Requires IOCB1616 circuit board ­ 16 inputs/16 outputs with jumper selectable supervised inputs

Management & Transaction Reports

· wide array of report options for comprehensive detail · schedule updated reports at desired intervals · automatically distributes reports to designated managers via email · save in PDF or CSV formats

Capitalize on Vantage's value-added benefits. Multiple Communication Managers

Run up to 5 communication managers on 1 PC. With Keyscan's VantageTM, customers can economize on PC expenses by installing multiple communication managers on 1 PC and still derive exceptional system communication across the full breadth of their corporate enterprise. There's no added software cost for installing and running multiple communication managers.

SDK (Optional)

Keyscan's optional Software Development Kit (SDK) offers a programming interface that allows end-user software to integrate with VantageTM access control software. Requires software development skills.

Keyscan Output Module

The Keyscan Output Module is designed to output Keyscan data in a flat file format (CSV) that can be integrated with 3rd party software.

Power-packed Utilities

Bundled with VantageTM are these compact, high-octane utilities. These versatile utilities add that extra dimension for superior access control management and operation. Keyscan Lockdown Utility ­ use either Present 3 or an alarm input to turn "OFF" a time zone that initiates a door lockdown. A terrific security feature. Auto Import Utility ­ imports new card records or updates existing card records for multiple sites at 1 minute intervals. Set it up once, and it's all done automatically. PING Alive Utility ­ quickly checks and summarizes access control unit communication. A convenient diagnostic to help pinpoint communication issues. Card Preview Utility ­ locates card records in seconds with a detailed summary. Lists all sites cardholders are authorized to access.

Keyscan's Optional Management Modules VantageTM CCTV Integration ­ VTVM

Keyscan's optional VTVM module integrates with several leading DVR brands, IP addressable cameras, and most RS-232 camera systems. Please contact Keyscan for supported DVR brands. · monitors multiple video feeds with on-screen camera commands · programs cameras to activate on specific alarm types · offers a full range of selectable camera presets including PTZs · retrieves alarm event video sequence captured in the DVR · combines with Keyscan's optional Photo Badge & Verification module

VantageTM Photo Badging ­VIDM

VantageTM Photo Badging adds an extra layer of security. This dual purpose optional module confirms cardholder identities with on-file images and conveniently integrates photo badging within the access control system.

Photo Verification

· displays cardholder image and details immediately after transaction · has "always on top" setting for constant monitoring · convenient comparison of incoming personnel to system registered photo identification · reinforces security at critical access points · adds another layer of protection

Photo Badge Editor

· has a full suite of badge design tools · convenient built-in feature for importing logos and backgrounds · supports a variety of industry-standard barcodes · supports most industry-standard card printers

VantageTM Control Module ­ VCM

Multi-faceted in function, dedicated in purpose, the VantageTM Control Module (optional) is designed specifically to help security personnel carry out their tasks systematically and efficiently. · displays floor plans to assist security personnel with building layout · provides interactive functionality to manually lock/unlock/ pulse doors or arm/disarm inputs from icons on an open map · programs relevant map to open automatically when an alarm is tripped - a flashing icon pinpoints the source · formats standardized security tours based on itinerary of readers and/or input points with timed intervals between devices · retains archival records with results of all security tours for management audits and reports · displays cardholder images on card transactions* * Requires optional Vantage Photo Badging ­ VIDM.

VantageTM Visitor Module ­ VVM

Keyscan's optional VantageTM Visitor Module has a full range of automation features for registering and monitoring visitors. · schedules visits, tracks visitor status, and retains a complete history · has an email notification feature to announce visitor arrivals · interfaces with Keyscan's business card scanner (P/N BIZSCAN) · imports contact information from MS OutlookTM contact list · interfaces with WindowsTM compatible or Dymo printers · formatted for Avery or similar type ID labels · assigns access cards

VantageTM ­ An Enterprise-Wide System

Keyscan access control and security systems are designed to optimize multi-communication modes for unlimited setup configurations. Whether you have serial, LAN/WAN network, or modem connections, you can program and control the entire Keyscan system from one or many locations using any or all three communication modes. Keyscan systems deliver consistent and reliable performance.

Client

Communications Manager

Unlimited Remote Locations

RS 485 or CANBUS Inter -panel communication

LAN/WAN (TCP /IP ) NETCOM 2 or NETCOM 6 (Encrypted) CA4000 CA8000 CA8000 EC 1000 CA8000

CANBUS ­ highly fault tolerant, robust communication using one twisted pair (CAT5 cable)

CA4000

EC 2000

CA8000

CA200

CA8000

Server

Client

Client RS 485 or CANBUS Inter-panel communication

Ethernet Ethernet

Communications Manager

CA4000 Direct Serial

RS232, RS485 or USB

CA8000

CA8000

Communications Manager LAN/WAN (TCP /IP ) RS 485 or CANBUS Inter-panel communication

CA4000

CA8000

CA8000

Corporate Head Offices

RS 485 or CANBUS

Dial Up Modem (MC33H) NETCOM 2 or NETCOM 6 (Encrypted) CA4000 CA8000 NETCOM 2 or NETCOM 6 (Encrypted)

Inter -panel communication

CA4000

EC 2000

CA8000

TELCO

CA4000

CA8000

LAN/WAN (TCP /IP )

EC 2000

CA8000

CA8000

RS 485 or CANBUS Inter -panel communication

There are many communication options availableFibre, LAN, WAN, COAX, Twisted Pair Call Keyscan for details .

Dial Up Modem (MC9600)

Dial-Up Location

CA200 CA4000

COnTROL UnIT STAnDARD FEATURES

· 5 door access group levels for enhanced flexibility · 5 elevator access group levels for enhanced flexibility · Stores up to 32,000 cards per site with no limit on number of sites · Create up to 512 door groups and 512 elevator groups · Retains last 6000 transactions in activity memory buffer · Create up to 256 time zones, 512 different schedules, and 3 different holiday types · Create up to 64 holiday dates · Monitors door forced open and door held open alarm conditions at reader-controlled doors · Monitors temporary cards with programmable date activation/ expiration and/or usage countdown · Unlimited remote sites via TCP/IP or dial-up modem · Heavy-duty 10 amp relays for long life and reliability · Dual processors for enhanced system performance panels operate during uploading and downloading of data · Removable terminal blocks for easier installation and service · Individual reader terminal blocks · Mix or match access control units for optimum installation · Simple jumper settings for most Wiegand protocols · Programs daylight savings and standard time to change automatically · 2 year warranty

COnTROL UnIT TEChnICAL SPECIFICATIOnS

OPErATING VOLTAGES Input transformers: 16 VAC, 37-40 VA Class II Internal Power Supply: 13.5 VDC @ 1.2 amps Battery Backup: 12VDC 7 Amp/Hr. OPErATING ENVIrONmENT 32° to 120° F. 0° to 49° C., Humidity: 0% to 90% R.H., noncondensing rELAy OUTPUTS Form C contacts, 10 Amps Max. 24 VAC or 32 VDC COmmUNICATION OPTIONS EIA/TIA 562 with CPB-10 RS485 with CB485 CANBUS with ECM or ACM ENCLOSUrE Single locking box CEMA / NEMA Type 1 Dimensions: 20 1/4" (51.4cm) H x 16 3/8" (41.6cm) W x 5 5/8" (14.3cm) D Net Weight: 15.8 lbs (7.2kg) rEADEr TECHNOLOGIES · Proximity · Contactless Smart Card · iClass · Radio Frequency (wireless parking applications) · Biometrics · Bar Code · Mag Stripe

The Enterprise Communication Module

It's built for speed and delivers data with integrity. The Enterprise Communication Module is a single circuit board that combines global system communication and panel to panel communication in 1 product using regular CAT5 cable. · Uses highly reliable CANBUS architecture for robust communication · Has high speed data transmission rate up to 57.6K BPS · Has ground loop prevention for inter-building communication · Highly fault tolerant · TCP/IP conversion available with optional NETCOM2P plug-in module · Supports PC to panel communication, panel to panel communication, and global functionality on single CAT5 cable run

ACU 1

ACU 2

ACU n

ECM 1 CANBUS 2

ECM 2

ECM n 1 twisted pair 1 twisted pair

CANBUS 1 ECM 0 serial or network connection CAT5

PC SPECIFICATIOnS

Faster processors and higher RAM provide better system performance. For large multi-site systems, please contact Keyscan for proper PC requirements. The following outlines minimum system requirements: · Recommended Central Processing Unit: P4 1.8 GHz · Minimum RAM: 512 megabytes or greater when setting up a single PC operation; 256 megabytes or greater when setting up individual modules on several PCs · Minimum Hard Disk: 20 Gigabytes · USB Port for Photo Badging and Signature Capture · COM Port: 1 required if direct connect to access control units, 2 required if using CCTV control with RS232 · CD-ROM Drive · Removable Media Storage Device such as a CD Writer for database backup · Network Interface Card (NIC) [Needed even for standalone PC operation] · Sound Card · Minimum 800 x 600 screen resolution · Operating System: Windows 2000, Windows 2000 Server, XP Professional, or Windows 2003 Server · Microsoft Internet Explorer 5.0.2314 or later

OVERVIEW OF ThE FEATURES In EVERy KEySCAn SySTEM

PANEL NAmE

DOOR OUTPUT RELAYS CARDS TRANSACTION FILE BUFFER TIME ZONES TIME SCHEDULES GROUP LEVELS HOLIDAY DATES VISITOR CARD READERS KEYPADS READER DOOR INPUTS EXIT BUTTON INPUTS ALARM OUTPUT RELAYS AUXILIARY INPUTS SUPERVISED INPUTS (OPTIONAL) SUPERVISED INPUTS / OUTPUTS (OPTIONAL) POWER FAIL OUTPUT ELEVATOR CONTROL FLOOR MONITOR INPUTS CONTROL PROCESSORS MANUAL RELAY OVERRIDE INDIVIDUAL TIME ZONES PER DOOR/READER INDIVIDUAL TIME ZONES PER FLOOR DIAL-UP MODEM ON REMOTE ALARM TIME ZONE CONTROL ON KEYPAD/READER USE MULTI SITE CARD WITH BATCH/FACILITY CODE ADDITIONAL ALARM OUTPUT RELAYS SERIAL COMMUNICATION DIAL-UP COMMUNICATION (OPTIONAL) LAN/WAN COMMUNICATION (OPTIONAL) ADD ON SUPPRESSOR KIT REQUIRED

CA 200

2 32000 6000 256 512 512 64 YES 2 2 2 2 2 8 NA NA YES NA NA 2 YES YES NA YES YES YES NA YES YES YES NO

CA 4000

4 32000 6000 256 512 512 64 YES 4 4 4 4 4 16 32/64 16-64 YES NA NA 2 YES YES NA YES YES YES 4 YES YES YES NO

CA 8000

8 32000 6000 256 512 512 64 YES 8 8 8 8 8 16 32/64 16-64 YES NA NA 2 YES YES NA YES YES YES NA YES YES YES NO

EC 1000

NA 32000 6000 256 512 512 64 YES 1 1 NA NA NA NA NA NA NA 1x40 Flrs YES 2 YES NA YES NA NO YES NA YES YES YES NO

EC 2000

NA 32000 6000 256 512 512 64 YES 2 2 NA NA NA NA NA NA NA 2x16 Flrs YES 2 YES NA YES NA NO YES NA YES YES YES NO

Keyscan's integration and dynamics allows companies to start with a small system and gradually grow to a full network of security and building management.

Reliability Flexibility Scalability

Keyscan Access Control Systems Deliver!

Valley Forge Security Center 117 Town Center Road King of Prussia, PA 19406 Phone: 610.265.3380 Fax: 610.265.7830 [email protected]

901 Burns Street East Whitby, Ontario, Canada L1N 6A6 Phone: 905.430.7226 Toll Free: 1.888.539.7226 Fax: 905.430.7275 www.keyscan.ca

Keyscan Inc. LR110441 Complies to: UL STD 294 Access Control System Units CSA STD C22.2 0.4-M1982 Bonding and Grounding of electrical equipment CSA STD C22.2 205-M1983 Signal Equipment CE