Read motor-accy-2004.pdf text version

MOTOR ACCESSORIES

RAINSHIELDS

Finned plastic rainshield provides additional motor cooling by drawing air through motor. Protects motor shaft bearing and windings from entrance of rain and snow. For use with vertically mounted condenser motors in shaft up position. OUTSIDE DIA.: 7.5

BORE SIZE 1/2 5/8

P195

Aluminum rainshield protects motor shaft bearing and windings from entrance of rain and snow. For use with vertically mounted condenser motor in shaft up position. OUTSIDE DIA.: 6.3

BORE SIZE 1/2 P/N P251-0051

P/N P251-0056 P251-0057

P199

Plastic slinger protects motor shaft bearing from rain. For use with vertically mounted condenser motors in shaft up position.

Plastic rainshield protects motor shaft bearing and windings from entrance of rain and snow. For use with vertically mounted condenser motors in shaft up position. OUTSIDE DIA.: 7.3

OUTSIDE DIA.: 3.5

BORE SIZE 1/2 5/8

P196

P/N P251-0058 P251-0059

P200

BORE SIZE 5/8

P/N P251-0052

Metal rainshield with rubber grommet to fit bearing hub protects motor windings only. Bearing slinger P251-0059 is also required for shaft bearing protection.

RUBBER FAN HUB CAP Rubber Fan Hub Cap prevents vertical mounted condenser fan from seizing to motor shaft.

P/N:

P201

STEEL SHAFT BUSHINGS

P251-0061

I.D. 5/16 5/16 3/8 1/2 1/2 5/8 5/8 3/4 1

O.D. 3/8 1/2 1/2 5/8 3/4 3/4 1 1 1-3/16

LENGTH 1-1/64 1-1/8 1-1/8 1-1/8 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4

P/N P251-0062 P251-0063 P251-0064 P251-0076 P251-0065 P251-0066 P251-0067 P251-0068 P251-0069

271

MOTOR ACCESSORIES

MOTOR ADAPTER KITS

MOLEX CONNECTOR KIT Facilitates speed changing on direct drive blower motors. Kit contains plastic insulating plug, mounting bracket and associated wire connectors.

P/N: P251-0055

P203

BELLY BAND ADAPTER KITS

P202

MOTOR FRAME 42 48

BOLT CIRCLE 9-9/32 10

EMERSON NO. 16 17

P/N P251-0010 P251-0011

MOTOR MOUNTS

FIG. B FIG. A FIG. D

P205

FIG. C

P204 P207 P206

THESE HEAVY DUTY WIRE FORMED MOTOR MOUNTS ARE ADAPTABLE TO MANY COMPETITIVE UNITS.

FOR MOTOR DIAMETER 5.6 5.6 5.6 5.6 6.6 6.6 6.6 6.6 FIG. WIRE DIA. A A A A D B D C .328 .375 .375 .375 .375 .375 .375 .375 BRACKET MOTOR MOUNTING MOUNTING DIMENSION P/N BOLT BOLT "A" CIRCLE CIRCLE 22.1 7.0 4.7 48DL400824 23.4 7.0 9.0 48DG400083 25.4 7.0 4.1 50PQ400763 27.4 7.0 4.4 38AE403493 27.4 18.3 48DG400024 36.0 6.1 38AE401574 36.0 13.1 48DD402564 36.8 11.8 50PQ400783*

P179-1

*Requires 09DC501181 ring. Requires 5ODD504272 ring.

272

MOTOR ACCESSORIES

MOTOR MOUNTS

Brackets for mounting direct drive blower motors which have 2-1/2 diameter resilient rings attached. Mount attached to the venturi of blower housing. The P251-0073 Motor Mount is an economical alternative to conventional mounts that require rubber grommets. · · · FITS 9 OR 10 IN. BLOWERS MAXIMUM MOTOR WEIGHT IS 16 LBS. USED WITH 5-1/2 DIAMETER DIRECT DRIVE BLOWER MOTORS.

P251-0073

P210

P/N:

P208

BLOWER SIZE 9 10 12

MAXIMUM MOTOR DIA. 5.5 7.5 7.5

BOLT CIRCLE 9.0 10.2 11.7

P/N P251-0070 P251-0071 P251-0072

MOTOR MOUNT KITS

Stamped steel motor mounting kits for 42 and 48 frame direct drive blower motors. Kit contains belly band, mounting arms, rubber isolation grommets and 1/4-20 sleeved bolts and nuts for attaching mount to fan housing. Use when replacing motors which originally had welded on mounting ears. Mounting ears have 5/16 slots and 3/4 knockouts which are adaptable to a wide range of mounting dimensions.

P209 P211

ADJUSTABLE MOTOR MOUNT KIT

P/N: P251-0015

MOTOR DIAMETER 5.5 5.0

BOLT CIRCLE 11.6 11.0

P/N P251-0074 P251-0075

273

MOTOR ACCESSORIES

PROTECTION CONTROL ­ HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE

Head Pressure Controls -- Temperature sensitive fan motor control which regulates head pressure at low ambients by varying the air volume through the condenser. Its unique construction permits exceptionally quick response times to changes in liquid line temperatures.

P/N P251-0083H P251-0094H DESCRIPTION HPC w/optional HP override Line Voltage HPC w/Optional HP Override Line Voltage HPC w/Optional HP Override HPC (Canada) APPLICATION Ideal for low ambient 120-480 VAC conditions found in: · Supermarkets 120 or 240 Frozen Storage VAC · Computer rooms 480 VAC · Temperature/ Humidity Sensitive Environments VOLTAGE

P251-0095H

P251-0083C

120-600 VAC

FEATURES/APPLICATION

SPECS

REPLACES

P/N:

P251-0083H

Input · Integral Heat Pump Bypass cir· Control: 18-30 cuitry allows electronic bypass VAC of speed control during heat Line Input: pump operation. 120-480 VAC · Eliminates overshoots common to on/off and pressure switch Output controls. · Tiac max: 10 amps · Helps prevent evaporator min: 100 ma freeze-ups, low pressure cut-outs and liquid-slugged · Range: 120-480 compressors in low ambient VAC conditions. · One model covers 120-480 VAC. · Features: hard start, low temperature cutoff, high temperature bypass, isolated 24 VAC supply.

One Totaline model replaces: · Hoffman: 800/800A/ 800AA/814-50 · Ranco: E31 Series · Johnson Controls: P66 · ACT: FM2000

P194

· Controls up to 3 refrigerant circuits. · Typical application: heat pumps.

274

Information