58HDV Direct Vent 4---Way Multipoise Condensing Gas Furnace 95% Downflow / Horizontal Orientations 93.5% Upflow Orientation

Product Data

95% Variable Speed Two-Stage Heating Furnace

FLEXIBILITY

S S S S Supports two-stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40in (1016mm) high with wider cabinets, for ease of installation Factory shipped for natural gas, with Propane Gas conversion kits available S Four-way multipoise installation S Vent pipe can be run horizontally or vertically S Internal condensate drain system S Self diagnostics S Entire blower assembly removable S S S S S S S S S S S S S Adjustable timed blower heating Off delay Adjustable timed blower cooling On/Off delay Thermal lined, one piece steel cabinet for noise reduction Insulated blower compartment 24 and 115VAC humidifier terminals Electronic air cleaner terminal Dehumidification option 95% AFUE Two-stage operation ECM Variable speed DC motor Two-stage Induced draft blower In-shot burners California NOx approved

Model Number 58HDV040 58HDV060 58HDV080 58HDV100 Dimensions H x W x D Inches 40 x 191/8 x 29 40 x 40 x 40 x 191/8 223/4 241/2 x 29 x 29 x 29 Millimeters 1016 x 486 x 737 1016 x 486 x 737 1016 x 578 x 737 1016 x 522 x 737 Input (MBTUH) 40 60 80 100

QUALITY

S S S S S S

Stainless steel heat exchanger Stainless steel secondary heat exchanger High temperature limit control prevents overheating Direct ignition with Silicon Nitride igniton Flame roll-out sensors standard External filter rack with permanent filters

!

WARNING

UNIT OPERATION HAZARD Failure to follow this warning could result in personal injury, death or property damage. This furnace is not designed for use in mobile homes, trailers, or recreational vehicles.

SERVICE

COMFORT

ama

DE

S I GN

EFFICIENCY

As an ENERGY STAR Partner, Carrier Corp. has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

ER

TIFIE

CERTIFIED

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

Efficiency AFUE 95 95 95 95 Cooling Capacity @ .5 in wc (125 Pa) 1.5 - 3.0 TON 1.5 - 3.5 TON 3 - 5.0 TON 3 - 5.0 TON Weight Lbs Kg 150 168 187 203 68 76 85 92

1

D

C

FURNACE SPECIFICATIONS

Model Number { INPUT { HTG. CAPACITY TEMP. RISE RANGE HIGH HEAT(BTUH) LOW HEAT (BTUH) HIGH HEAT(BTUH) LOW HEAT (BTUH) HIGH HEAT (oF/oC) LOW HEAT(oF/oC) 58HDV040 40,000 28,000 38,000 27,000 25-- 55/14-- 31 25-- 55/14-- 31 2 (51) OD 115/60/1 9.5 104/127 40 1/2 (12.7) 3.0 1177766 16X25X1 (406x635x25) (1) 191/8x29x40 (486x737x1016) 150 (68) 58HDV060 60,000 42,000 58,000 41,000 30-- 60/17-- 33 30-- 60/17-- 33 2-- 3 (51 - 76) OD 115/60/1 11.4 104/127 40 1/2 (12.7) 3.5 1177767 16X25X1 (406x635x25) (1) 191/8x29x40 (486x737x1016) 168 (76) 58HDV080 80,000 56,000 77,000 54,000 30-- 60/17-- 33 30-- 60/17-- 33 3 (76) OD 115/60/1 14.6 104/127 40 1/2 (12.7) 5.0 1177768 16X25X1 (406x635x25) (2) 223/4x29x40 (486x737x1016) 187 (85) 58HDV100 100,000 70,000 96,000 67,000 30-- 60/17-- 33 30-- 60/17-- 33 3 (76) OD 115/60/1 14.6 104/127 40 1/2 (12.7) 5.0 1177769 16X25X1 (406x635x25) (2)

241/2x29x40 (622x737x1016) 203 (92)

VENT SIZE^ in(mm) VOLTS/HZ/PH RATING PLATE AMPS. MIN./MAX. VOLTAGE TRANSFORMER (V.A.) GAS PIPE SIZE - inches(mm) COOLING CAP. (TONS) HIGH ALTITUDE PRESSURE SWITCH FILTER SIZE - inches(mm) (qty) DIMENSIONS - WxDxH inches(mm) WEIGHT - Lbs(kg)

58HDV

^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. { Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA for elevations above 2000 ft. (610 M), ratings must be derated 2% (natural gas) or 4% (propane gas) for each 1000 ft. (305 M) above sea level. In Canada for altitudes of 2000 ft. (610 M) to 4500 ft. (1372 M) ratings must be derated 5% (natural gas) and 10% (propane gas).

Cabinet to Combustible Clearances - in(mm) TOP 1 (25.4) BOT 0 RH 0 LH 0 BACK 0 FRNT 3(76.2) FLUE 0

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS - in (mm) F AIR INTAKE VENT A B

REAR FRONT (combustion air openings in furnace and in structure) Required For Service ALL SIDES Of SUPPLY PLENUM SIDES VENT TOP OF FURNACE

0 3" (76.2)

TOP

H G E

*24" (609.6)

1" (25.4) 0 0 1" (25.4)

FRONT

LEFT SIDE

TRAP (KO) (COUNTERFLOW)

(177.5)

611/16

ELECTRICAL 11/4 (318)

*30 " (762mm) clearance recommended for furnace removal. Horizontal position: Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs or framing.

11 13 /16 (347.7)

GAS VENT AIR INTAKE (KO) (ALTERNATE) 413/16 (122.2) TRAP (KO) UPFLOW/HORIZONTAL 21/4 (57.2) THERMOSTAT

(177.8)

11/16 (27)

(34.9) 13/8

7

11 31 /16 (804.9) (758.8) 7 29 /8 3 28 /4 (730.3) 13 19 /16 (503.2)

11/4 (31.7)

NOTE: Evaporator "A" coil drain pan dimensions may vary from furnace duct opening size. Always consult evaporator specifications for duct size requirements. Furnace is designed for bottom return or side return. Return air through back of furnace is NOT allowed.

(336.6)

1 13 /4

(KO)

(439.7) 111/16 (42.9)

5 17 /16

1 24 /16 (611.2)

27/8

(73)

45/16 (109.5)

23/8(60.3 ) 11/16(27) GAS (KO)

1 28 /2 (723.9) 1 18 /2 (469.9)

(19.1) 3/ 4

TYPE

(47.6 )

17/8

5 21 /8 (549.3)

(609.6)

24

47/8 (123.8) KO = KnockOut

RIGHT SIDE

TRAP (KO) (COUNTERFLOW)

ELECTRICAL (KO)

ALL DIMENSIONS: in (mm) BOTTOM

(30.2)

13/16

(122.2)

413/16

AIR INTAKE (KO) (ALTERNATE) VENT (KO) TRAP (KO) UPFLOW/HORIZONTAL 40

(1016)

D

C

1 23 /8 (587.4)

37/8

(98.4)

11/16 7 (27) 29 /8 (758.8) 21/4 7 3 27 /16 (57.2) (177.8) (690.6) 5 THERMOSTAT 21 /8 913/16 (549.3) 1 (249.2) 13 /4 5 17 /16 (336.6) 11 (439.7) 33 /16 11 (KO) (855.7) 1 /16 (42.9)

47/8 (123.8)

5 21 /8 (549.3)

17/8

(609.6)

24

(47.6)

A09241

2

ACCESSORIES

Model Number KGANP47012HW KGAPN40012HW KGAFR0901P16 KGAFR1001P20 P908-0001+ KGAVT0801CVT Description Gas Conversion Kits - Natural gas to propane conversion Kit. Allows field conversion to propane gas. Gas Conversion Kits - Propane to natural gas conversion kit. Allows field conversion to natural gas. Filter Kits - External filter frame. 16 x 25 (406 x 635 mm) Filter Kits - External filter frame. 20 x 25 (508 x 635 mm) Condensate neutralizer kit - for condensing gas furnaces 3 (76 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). 2 (51 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit High Altitude Pressure Switch Kit Combustible Floor Base without cased coil used Combustible Floor Base used with cased coil used Downflow Coil Adapter Used With Models 58HDV 58HDV 58HDV 58HDV All if required 58HDV060 58HDV080 58HDV100 58HDV060 58HDV080 58HDV100 58HDV040 58HDV080 58HDV100 58HDV 58HDV 58HDV Size 41 Size 42 Size 43 Size 44 Size 45 Orifice Kit (Qty. 5) Size 46 Size 47 Size 48 Size 49 Size 54 Size 55 Size 56

KGAVT0701CVT KGAHA6101PSW KGAHA6201PSW KGAHA6301PSW KGAHA6401PSW KGASB0301P01 KGASB0401P02 KGASB0801P06 KGASB0501P03 KGASB0601P04 KGASB0701P05 KGADA0101PYN 333730-701 333730-702 333730-703 333730-704 333730-705 333730-709 333730-710 333730-711 333730-712 333730-706 333730-707

+

333730-708

Must be ordered from Service Parts

3

58HDV

58HDV060,

Circulation Air Blower Data - 58HDV040 Cooling Adjustment DIP Switch

(OFF = 0 ON = 1)

Heating Rise Adjustment ** Adjust Jumper Setting + *NOM + NOM + NOM + NOM DIP Switch

(OFF = 0 ON = 1)

High Cool @ .50 in wc(125 Pa) CFM 1244 1206 1126 1109 1032 941 901 828 757 705 633 556 L/s 587 569 531 523 487 444 425 391 357 333 299 262

Low Cool (80% of High Cool) CFM 995 965 901 887 826 753 721 662 606 564 506 445 L/s 470 455 425 419 390 355 340 313 286 266 239 210

5&6 00 *00 00 01 01 01 10 10 10 11 11 11

3&4 00 *00 00 01 01 01 10 10 10 11 11 11

High Heat Rise Change @ 0.20 in wc (50 Pa) -3 0 4 2 6 13 0 3 8 --12 --10 --8

Low Heat Rise Change at Resultant Static --3 0 4 2 6 10 --1 3 7 --13 --10 --8

58HDV

Airflow performance includes 1" washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the "O" line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings.

Table 2 DIP Switch

(OFF = 0 / ON = 1)

Airflow Continuous Fan @ 0.10 in wc (25 Pa) ESP CFM L/s 592 279 1021 482 1346 635 1346 635

1&2 *00 01 10 11

* Factory Setting

Table 3 DIP Switch 1&2 3&4 5&6 7&8

SW2 DIP Assignments Blower Parameter Cont Fan Adj Heat Speed Adj Cool Speed Adj Cool On/Off Delay

Table 4 DIP SW2 - 7/8 (OFF = 0 / ON = 1)

Cooling Delay Options (SW2 - 7, 8) ON DELAY OFF DELAY Timed ON (sec) 5 5 30 30 Airflow during on delay OFF OFF 50% 50% Timer OFF (sec) 90 0 30 180 Airflow during off delay 100% OFF 100% 50%

*00 01 10 11

Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 100% after on delay time is completed Airflow stops (or switches to continuous fan speed) after off delay time is completed * Factory Setting

MAX CFM's for Factory Washable Filters Filter Size (in/mm) 14 X 25 / 356 x 635 16 X 25 / 406 x 635 20 X 25 / 508 x 635 24 X 25 / 610 x 635 CFM 1400 1600 2000 2500 L/s 661 755 944 1180

NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 25in @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM 508mm x 635mm @ 3.0 M/s = 944 L/s, @ 1.5 M/s = 472 L/s

Max CFM based on 600 FPM (3.0 M/s)

4

Circulation Air Blower Data - 58HDV040

Cooling Airflow Settings

High Cool Airflow

1400 00 + 00 NOM 1200 00 01 + 01 NOM 1000 01 10 + 800 10 11 + 600 11 NOM 11 10 NOM

400

200

0 0.0 0.1 0.2 0.3 0.4 0.5 ESP (inches of wc) 0.6 0.7 0.8 0.9 1.0

Low Cool Airflow

1200 00 + 00 NOM 00 1000 01 + 01 NOM 01 800 10 + 10 NOM 10 11 + 600 11 NOM 11 -

CFM

400

200

0 0.0 0.1 0.2 0.3 0.4 0.5 ESP ( inches of wc) 0.6 0.7 0.8 0.9 1.0

5

58HDV

CFM

Circulation Air Blower Data - 58HDV060 Cooling Adjustment DIP Switch

(OFF = 0 ON = 1)

Heating Rise Adjustment ** Adjust Jumper Setting + *NOM -+ NOM -+ NOM -+ NOM -DIP Switch

(OFF = 0 ON = 1)

High Cool @ .50 in wc(125 Pa) CFM 1377 1239 1097 1165 1044 889 966 848 715 74 650 523 L/s 650 585 518 550 493 420 456 400 337 353 307 247

Low Cool (80% of High Cool) CFM 1102 991 878 932 835 711 773 678 572 599 520 418 L/s 650 585 518 550 493 420 456 400 337 353 307 247

5&6 00 *00 00 01 01 01 10 10 10 11 11 11

3&4 00 *00 00 01 01 01 10 10 10 11 11 11

High Heat Rise Change @ 0.20 in wc (50 Pa) --3 0 3 1 4 8 --1 2 7 --5 --2 1

Low Heat Rise Change at Resultant Static --3 0 3 2 4 8 0 2 7 --4 --2 1

58HDV

Airflow performance includes 1" washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the "O" line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings.

Table 2 DIP Switch

(OFF = 0 / ON = 1)

Airflow Continuous Fan @ 0.10 in wc (25 Pa) ESP CFM L/s 612 475 1096 822 1403 1040 1403 1040

1&2 *00 01 10 11

* Factory Setting

Table 3 DIP Switch 1&2 3&4 5&6 7&8

SW2 DIP Assignments Blower Parameter Cont Fan Adj Heat Speed Adj Cool Speed Adj Cool On/Off Delay

Table 4 DIP SW2 - 7/8 (OFF = 0 / ON = 1)

Cooling Delay Options (SW2 - 7, 8) ON DELAY OFF DELAY Timed ON (sec) 5 5 30 30 Airflow during on delay OFF OFF 50% 50% Timer OFF (sec) 90 0 30 180 Airflow during off delay 100% OFF 100% 50%

*00 01 10 11

Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 100% after on delay time is completed Airflow stops (or switches to continuous fan speed) after off delay time is completed * Factory Setting

MAX CFM's for Factory Washable Filters Filter Size (in/mm) 14 X 25 / 356 x 635 16 X 25 / 406 x 635 20 X 25 / 508 x 635 24 X 25 / 610 x 635 CFM 1400 1600 2000 2500 L/s 661 755 944 1180

NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 25in @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM 508mm x 635mm @ 3.0 M/s = 944 L/s, @ 1.5 M/s = 472 L/s

Max CFM based on 600 FPM (3.0 M/s)

6

Circulation Air Blower Data - 58HDV060

Cooling Airflow Settings

High Cool Airflow chart

1800 00+ 00NOM 001600 01+ 01NOM 011400 10+ 10NOM 1200 1011+ 11NOM

800

600

400

200

0 0 0.1 0.2 0.3 0.4 0.5 ESP (inches of wc) 0.6 0.7 0.8 0.9 1

LowCool Airflowchart

1400

00+ 00NOM 0001+ 01NOM 0110+ 10NOM 1011+ 11NOM

1200

1000

800

11-

CFM

600

400

200

0 0 0.1 0.2 0.3 ESP (inchesof wc) 0.4 0.5 0.6 0.7

7

58HDV

1000

11-

CFM

Circulation Air Blower Data - 58HDV080 Cooling Adjustment DIP Switch

(OFF = 0 ON = 1)

Heating Rise Adjustment ** Adjust Jumper Setting + *NOM -+ NOM -+ NOM -+ NOM -DIP Switch

(OFF = 0 ON = 1)

High Cool @ .50 in wc(125 Pa) CFM 2146 2009 1843 1779 1645 1498 1409 1294 1147 1005 887 757 L/s 1013 948 870 840 776 707 665 611 541 474 419 357

Low Cool (80% of High Cool) CFM 1717 1607 1474 1423 1316 1198 1127 1035 918 804 710 606 L/s 1013 948 870 840 776 707 665 611 541 474 419 357

5&6 00 *00 00 01 01 01 10 10 10 11 11 11

3&4 00 *00 00 01 01 01 10 10 10 11 11 11

High Heat Rise Change @ 0.20 in wc (50 Pa) --3 0 5 3 6 11 0 6 10 --5 --2 3

Low Heat Rise Change at Resultant Static --3 0 5 3 8 11 0 4 9 --6 --2 2

58HDV

Airflow performance includes 1" washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the "O" line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings.

Table 2 DIP Switch

(OFF = 0 / ON = 1)

Airflow Continuous Fan @ 0.10 in wc (25 Pa) ESP CFM L/s 1007 475 1742 822 2204 1040 2204 1040

1&2 *00 01 10 11

* Factory Setting

Table 3 DIP Switch 1&2 3&4 5&6 7&8

SW2 DIP Assignments Blower Parameter Cont Fan Adj Heat Speed Adj Cool Speed Adj Cool On/Off Delay

Table 4 DIP SW2 - 7/8 (OFF = 0 / ON = 1)

Cooling Delay Options (SW2 - 7, 8) ON DELAY OFF DELAY Timed ON (sec) 5 5 30 30 Airflow during on delay OFF OFF 50% 50% Timer OFF (sec) 90 0 30 180 Airflow during off delay 100% OFF 100% 50%

*00 01 10 11

Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 100% after on delay time is completed Airflow stops (or switches to continuous fan speed) after off delay time is completed * Factory Setting

MAX CFM's for Factory Washable Filters Filter Size (in/mm) 14 X 25 / 356 x 635 16 X 25 / 406 x 635 20 X 25 / 508 x 635 24 X 25 / 610 x 635 CFM 1400 1600 2000 2500 L/s 661 755 944 1180

NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 25in @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM 508mm x 635mm @ 3.0 M/s = 944 L/s, @ 1.5 M/s = 472 L/s

Max CFM based on 600 FPM (3.0 M/s)

8

Circulation Air Blower Data - 58HDV080

Cooling Airflow Settings

High Cool Airflows

2400 00 + 00 NOM 00 01 + 01 NOM 0110 + 10 NOM 10 11 + 11 NOM 11 -

2000

1600

1200

800

400

0 0.0 0.1 0.2 0.3 0.4 0.5 ESP (inches of wc) 0.6 0.7 0.8 0.9 1.0

LowCool Airflow

2000 1800 1600 1400 1200

00 + 00 NOM 00 01 + 01 NOM 01 10 + 10 NOM 10 11 + 11 NOM 11 -

CFM

1000 800 600 400 200 0 0.0

0.1

0.2

0.3

0.4

0.5 ESP(inches of wc)

0.6

0.7

0.8

0.9

1.0

9

58HDV

CFM

Circulation Air Blower Data - 58HDV100 Cooling Adjustment DIP Switch

(OFF = 0 ON = 1)

Heating Rise Adjustment ** Adjust Jumper Setting + *NOM -+ NOM -+ NOM -+ NOM -DIP Switch

(OFF = 0 ON = 1)

High Cool @ .50 in wc(125 Pa) CFM 2108 1974 1812 1712 1587 1422 1312 1197 1056 919 797 641 L/s 995 932 855 808 749 671 619 565 498 434 376 303

Low Cool (80% of High Cool) CFM 1686 1579 1450 1370 1270 1138 1050 958 845 735 638 513 L/s 995 932 855 808 749 671 619 565 498 434 376 303

5&6 00 *00 00 01 01 01 10 10 10 11 11 11

3&4 00 *00 00 01 01 01 10 10 10 11 11 11

High Heat Rise Change @ 0.20 in wc (50 Pa) --3 0 4 1 4 9 --2 1 5 --5 --3 2

Low Heat Rise Change at Resultant Static --3 0 5 1 5 10 --1 2 7 --6 --3 2

58HDV

Airflow performance includes 1" washable filter media. *Factory Setting **Adjust Jumper Setting (+, NOM, --) is applied to both Cooling and Heating Note 1: HP Mode Jumper provides a 10% reduction in airflow when in Comfort position and a call for low or high cooling is present with the "O" line off. This feature is to provide lower airflow for running in HP Heating Mode if desirable. Note 2: DEHUM mode (24VAC on DEHUM terminal) provides a 20% airflow reduction during cooling calls. Note 3: Low Heat ESP is a result of High Heat ESP (-- is decrease in rise). Note 4: High and low heat rise values are approximate air temperature change from return air temperature when at factory default settings.

Table 2 DIP Switch

(OFF = 0 / ON = 1)

Airflow Continuous Fan @ 0.10 in wc (25 Pa) ESP CFM L/s 1032 487 1778 839 2178 1028 2178 1028

1&2 *00 01 10 11

* Factory Setting

Table 3 DIP Switch 1&2 3&4 5&6 7&8

SW2 DIP Assignments Blower Parameter Cont Fan Adj Heat Speed Adj Cool Speed Adj Cool On/Off Delay

Table 4 DIP SW2 - 7/8 (OFF = 0 / ON = 1)

Cooling Delay Options (SW2 - 7, 8) ON DELAY OFF DELAY Timed ON (sec) 5 5 30 30 Airflow during on delay OFF OFF 50% 50% Timer OFF (sec) 90 0 30 180 Airflow during off delay 100% OFF 100% 50%

*00 01 10 11

Airflow % is of High Cool airflow demand determined from SW2--5/6 Table 1 Airflow resumes to 100% after on delay time is completed Airflow stops (or switches to continuous fan speed) after off delay time is completed * Factory Setting

MAX CFM's for Factory Washable Filters Filter Size (in/mm) 14 X 25 / 356 x 635 16 X 25 / 406 x 635 20 X 25 / 508 x 635 24 X 25 / 610 x 635 CFM 1400 1600 2000 2500 L/s 661 755 944 1180

NOTE: Disposable filters are typically rated at 300 FPM (1.5 m/s). These filters only allow half the airflow when compared to 600 FPM (3.0 M/s) filters. EXAMPLE (approx.): 20in X 25in @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM 508mm x 635mm @ 3.0 M/s = 944 L/s, @ 1.5 M/s = 472 L/s

Max CFM based on 600 FPM (3.0 M/s)

10

Circulation Air Blower Data - 58HDV100

Cooling Airflow Settings

High Cooling Airflows

2600 00 (+) 00 (NOM) 00(-) 2200 01(+) 01(NOM) 01(-) 1800 10(+) 10(NOM) 10(-) 1400 11(NOM) 11(-) 11(+)

1000

600

200 0.0 0.1 0.2 0.3 0.4 0.5 ESP (inchesof wc) 0.6 0.7 0.8 0.9 1.0

Low Cool Airflow

2000 1800 1600 1400 1200 00+ 00NOM 0001+ 01 NOM 01 10+ 10 NOM 10 11+ 11 NOM 11 -

CFM

1000 800 600 400 200 0 0.0 0.2 0.4 ESP (inches of wc) 0.6 0.8 1.0

11

58HDV

CFM

ON

58HDV

=

1 8

1

OFF

=

0

Variable Speed Tap Select Interface Board (TSIB)

A09242

Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 04/09

Catalog No: 58HDV ---01PD

Replaces: NEW

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

12

Information

58HDV-01PD