Read Microsoft Word - H8C Rev8.doc text version

Datasheet: H8C load cell

OIML test certificate no. TC8012 revision 1 OIML C of C no. R60/2000 ­ NL1-12.12 NTEP certificate no. 12-028

Capacity 100 kg 250 kg 500 kg 1t 1,5t 2t 2.5t 3t 5t 10t

Accuracy Cx Cx Cx Cx Cx Cx Cx Cx Cx Cx

Type Bending Bending Shear Shear Shear Shear Shear Shear Shear Shear

Part-Number H8C-Cx-100kg-4B H8C-Cx-250kg-4B H8C-Cx-500kg-4B H8C-Cx-1.0t-4B H8C-Cx-1.5t-4B H8C-Cx-2.0t-4B H8C-Cx-2.5t-6B H8C-Cx-3.0t-6B H8C-Cx-5.0t-6B H8C-Cx-10t-6B Alloy steel IP67 beam load cell Adhesive sealed Suitable for platform weighing, bed weighing, etc. High accuracy, high reliability

Specification:

Accuracy class Output sensitivity ( = FS ) Nominal capacity ( Emax ) Maximum number of load cell intervals ( nLC ) Ratio of minimum LC verification interval Y = Emax / vmin Combined Error Minimum dead load Safe overload Ultimate overload Zero balance Excitation, recommended voltage Excitation maximum Input resistance Output resistance Insulation resistance Temperature range, compensated Temperature range, operating Element material Ingress Protection (according to EN 60529) Recommended torque on fixation bolts ATEX classification (optional)

Note 1: Current calibration (SC) is optional. Note 2: Imperial capacities also available.

mV/V1 t2 Y %FS t of Emax of Emax of FS V AC/DC V AC/DC M °C °C

OIML R60 C3

OIML R60 C4 3.0 ± 0.0031

OIML R60 C5 0.1, 0.25, 0.5, 1, 1.5, 3, 5, 10 2, 2.5, 5000 20.000 18.000 ± 0.014

0.1, 0.25, 0.5, 1, 1.5, 2, 2.5, 3, 5, 10 3000 10.000 ± 0.023

Nm

4000 15.000 ± 0.0175 0 150 % 300 % ± 1.0 % 5 ~ 12 18 350 ± 3.5 350 ± 3.5 5000 ( at 50VDC ) -10 ~+40 -35 ~ +65 Alloy steel nickel plated IP67 M12: 100 M18: 200 M24: 700 II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4

Ordering Info:

H8C - C3 ­ 1.0t ­ 4 - BX - SC ­ XX Option XX. No mark is standard version, W4 is through loading hole, W6 is "T" end loading hole. Option SC (standard current) Cable option. No mark is 4 conductor cable and with "6" a 6 conductor cable. Thread option. No mark is Metric thread and "Y" is Imperial thread. Length of the cable in meters. Nominal capacity (Emax) for Metric in t(on) and Imperial in lbs up to 500lbs and above in K(ilo)lbs. Maximum Load Cell Divisions Load Cell model. Shielded, 4 conductor cable: Ø 5mm. Standard cable length: 4m up to 2t and 6m for the higher capacities. Shield in not connected to the element. Cable type and length can be changed on customer's request.

Please visit our website WWW.ZEMIC.NL for the most actual information

Page 1 of 2

Nr. 2012.05 H8C Rev8

Datasheet: H8C load cell

Outline Dimensions in mm

Standard version

Option W4 (through loading hole)

Option W6 ("T" end loading hole)

Capacity 0.1t ­ 2t 200lb ­ 4klb 5Klb (SE) 2.5t ­ 5t 5Klb ­ 10Klbs 10t 20Klb

L 130 130 130 171.5 171.5 222.3 222.3

L1 15.8 15.8 15.8 19.1 19.1 25.4 25.4

L2 25.4 25.4 25.4 38.1 38.1 50.8 50.8

L3 76.2 76.2 76.2 95.3 95.3 120.7 120.7

L4 54.2 54.2 54.2 77.2 77.2 101.6 101.6

B 31.8 31.8 31.8 38.1 38.1 50.8 50.8

B1 34 34 34 40 40 52.4 52.4

H 31.8 31.8 31.8 38.1 38.1 50.8 50.8

H1 15.8 15.8 15.8 18.8 18.8 25.4 25.4

H2 14.5 14.5 14.5 17.5 17.5

H3 15.8 15.8 15.8 18.8 18.8

H4 4.8 4.8 4.8 4.8 4.8

ØD 13.5 13.5 13.5 19.8 19.8 26 26

ØD1 18 18 18 25 25

Ød1 4 4 4 4 4

Ød2 2 2 2 2 2

M M12x1.75 ½-20UNF ½-20UNF M18x1.5 ¾-16UNF M24x2 1-12UNF

Please visit our website WWW.ZEMIC.NL for the most actual information